| Sl. No. | Item Description |
| 1 | Wiring points for light with 1.5 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along withthe reinforcementbefore concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copperconductorcable as earth continuity wire and modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic Laminated backalite sheet etc. complete in all respects. P.W.D.S.O.R. 2018 S.I. No. 138C + 187A) |
| 2 | Same as item No.(1) but for two way Light Points.P.W.D.S.O.R. 2016 S.I. No. 139 ( C )+187A |
| 3 | Same as item No.(1) but for fanandlight duty exhaust fan.P.W.D.S.O.R. 2016 S.I. No. 140 (C ) + 187A |
| 4 | Same as item No.(1) but for5 Amp plug point with modular type switch and socket etc.P.W.D.S.O.R. 2016 S.I. No.141 (C ) |
| 5 | Supply and wiring of submain 2 number 2.5 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 1.5 sqmm FR PVC insulated multistranded copper conductorcable as earth contunity wire etc. complete in all respects. P.W.D.S.O.R. 2018 S.I. No.1307 (C ) |
| 6 | Supply and wiring of submain 2 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FR PVC insulated multistranded copper conductorcable as earth contunity wire etc. complete in all respects. P.W.D.S.O.R. 2018 S.I. No.221 (C ) |
| 7 | Supply and wiring of submain 2 number 10 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 32mm dia PVC conduit partly concealed in wall and partly laid in slab along with Two number 6 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.P.W.D.S.O.R. 2018 S.I. No.291 (G ) |
| 8 | Supply and wiring of submain 4 number 10 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 32mm dia PVC conduit partly concealed in wall and partly laid in slab along with Two number 6 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.P.W.D.S.O.R. 2018 S.I. No.278 (C ) |
| 9 | S/F of hexagonal fan box with hexagonal side of approx 80 mm in length fabricated from 16SWG M.S. sheet incorporating 10 mm dia, M.S. round bar duly bent for supporting fan hanger dully painted with red oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., Required for proper completion of the work. P.W.D.S.O.R. 2018 S.I. No.1149 |
| 10 | Supply & fixing ofLED Tube Light with battern suitable for up to 1 x 22 watt LED Tube light complete including tube etc on surface complete in all respect P.W.D. S.O.R. 2018 S.I. No.1413 |
| 11 | Supply & fixing ofLED Tube Light with battern suitable for up to 2 x 22 watt LED Tube light complete including tube etc on surface complete in all respect P.W.D. S.O.R. 2018 S.I. No.1414 |
| 12 | Add for fixingoftubefitting aspendentwithtwonumber 19 mmdia 16gaugerigidsteelconduitdoublechecknuts: spring loaded flanges or M.S. hookfabricated from 25 mm x 3mmflatirondulygroutedintheceilingupto 3.5 height of ceiling including painting with synthetic enamel Paint along with supply of all materials , labour T & Petc. required for proper completion of work .P.W.D.S.O.R. 2018 S.I. No.1143 |
| 13 | S/F of 9 Watt LED bulb |
| 14 | Making hole in the wall for exhaust fan and finishing properly completeinallrespects.P.W.D.S.O.R. 2018 S.I. No.1121 |
| 15 | Supply and fixing ofElectronic FanRegulator 120-280 VISI marked, on the existingswitch board including making connections,requiredmaterial,labourT&Petc.for proper completion of work to the satisfaction of Engineer Inchargeof work. P.W.D.S.O.R. 2018S.I. No.1203 (A) |
| 16 | S/F of 3mmthickbakelitesheetcover round /hexagonal Type for fan box complete with all material ,labour ,T&P as per direction of E/I |
| 17 | S/Fof 3mmthick Al. sheet junction box cover,Complete with all material labour ,T&P As per direction of E/I |
| 18 | Supply and fixing of 4 way T.P.N. flush / surface mountingTPN distribution board without MCBcomplete in all respects as directed at site by E / I(S.I. No.1026ACat C) |
| 19 | Supply and fixing of6 Amp. To 32 Amp. MCB (10 K A ) .P.W.D.S.O.R. 2018 S.I. No.1002 Cat B |
| 20 | Suppy and Fixingof 40 Amp 4 pole MCB 10 KA.(S.I. No.1020 Cat A) |
| 21 | Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 15 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material Labour T&Petc required for proper completion of work. P.W.D.S.O.R. 2018 S.I. No.1139 A |
| 22 | Supplyand burring of safe Earthing ElectrodeT – 19 (Hot Dip Galvanized) Length 3000 mm outer pipe 50 mm inner pipe 25 , terminal Dia 12 mm outer G.I. pipe of 16 swg and inner G.I. pipeof 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover and masonry housing P.W.D.S.O.R. 2018 S.I. No.725 B |
| 23 | Supplying & Laying of 25mm x 3 mm G.I. Strip for earth Electrode directly in the ground as required complete in all respects. P.W.D.S.O.R. 2018 S.I. No.716 |
| 24 | S / F of 100 mm dia G.I.pipe \"B\" class for cable completed with supports.by 3 Nos.clamp made for 20x30 mm MS flat and suitable size of nut,bolt & Washer required for proper completion of work as per direction of E/I D.S.R. 2018Item Code No. 14.13.3 |
| 25 | Supply and erection of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan without regulater standard down rod, blades including connection etc. complete as required as per direction of E/I Make :- Bajaj, Crompton or Equivalent |
| 26 | Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep. as per direction of E/I Make :- Bajaj, Crompton or Equivalent |
| 27 | S / F of Change over switch on angle iron frame ,including the cost of labour T & P painting and other material required for proper completion of the work as per direction & satisfation of E / I 100 Amp.foure pole on 40 mm x 40 mm x 6 mm angle iron frame P.W.D.S.O.R.2018 S.I.No. 378 |
| 28 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc.complete in all respects.The instrument chamber shall be separated and shall comprise of flush type ammeter ,voltmerer ,selector switches for ammeter and voltmeter ,instrument fuse ,current transormer etc.The board shall have suitable capacity electroytic aluminium busbars as per IS 8623 istulate with heat shrink sleving and mounted on non hygroscopic supports such as CMC / DMC support with deteachable side covers and shall besuitable for extension on the sides The switches shall becomplete with suitable cable end boxex ,reverse entery boxex in case of pedestaal type ,cable sockets compression glands and including lamp on incoming etc.The Job includes the grounting of the board as per direction of E/I. All outgoing switches of 100 amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm / 2 mm cubicle type switch board shall be ofcat A B & B - II and pedestal type for cat -B and C only.Wall Mounted Panel 1,2,3,4 Incoming 100 Amp T.P.N 1 No.100 Amp. Al. Busbar of suitable lenthoutgoing 63 Amp TPN 3 Nos.63 Amp TPN 2 Nos. SparePWD SOR 2018 S.I. No. 801 B |
| 29 | Wall Mounted Panel 1,2,3,4 Incoming 100 Amp T.P.N 1 No.100 Amp. Al. Busbar of suitable lenthoutgoing 63 Amp TPN 3 Nos.63 Amp TPN 2 Nos. Spare |
| 30 | Supply & laying ofaluminium conductor PVCinsulatedarmoured served sheathed cables 1100 Volts grateata depthofbelowground level over a cushion of 75mm. below groundlevel over a cushion of 75mm. thicksand alround and protected with burnt bricks on sides and on top.On surface the cable run shallbefixedonM.S. clamps etc. ofsuitablesizeorasdirectedby the Engineer-incharge, complete in all respects. The armouringof the cable shall be properly connected with the earth conductor by clamps etc. PWD SOR 2018S.I. 501 |
| 31 | 10 Sq.mm 2 Core |
| 32 | 16 Sq.mm 4 Core |
| 33 | 240 Sq.mm 3 ½ core |
| 34 | Supply & Fixing of Bress nickle plated compression gland for PVC insulated and around served sheathed underground cable including rubber ring etc complete in all respect PWD SOR 2018S.I. 503 |
| 35 | 10 Sq.mm 2 Core |
| 36 | 16 Sq.mm 4 Core |
| 37 | 240 Sq.mm 3 ½ core |
| 38 | Supply & fixing of plain or pin type copper tin plated cable socket (lug)to the cable leads,insulated with tapeand making connection etc.complete in all respectas per direction of E/I PWD SOR 2018S.I. 504 |
| 39 | 10Sq. mm |
| 40 | 16 Sq. mm |
| 41 | 120 Sq. mm |
| 42 | 240 Sq. mm |
| 43 | Type I 2 Nos.supply and fixing of 32 A. 240 V D.P. Metal rewireable type switch fuse unit on M.D.F.E. / teak wood board complete in all respect P.W.D.S.O.R. 2016 S.I. No.305 B |
| 44 | Supply and fixing of flush / surface mounting4 ways SPN distribution board with additinal metal door withought M.C.B. Complete in all respects.as directed at site by E / IP.W.D.S.O.R. 2016 S.I. No. 1022 Cat A |
| 45 | Supply and Fixing of 6 to 32 Amp.D.P. MCB 10 KA(Legrand / Lexice) P.W.D.S.O.R. 2016 S.I. No. 1009 Cat C |
| 46 | Supplying & fixing of 1 No.8 SWG G.I. Wire in 15 mm dia for earthing laid ingroundor in wall duly concealed including the cost of cement sand labour T&P other material required for proper completion of the work as directed as site(P.W.D. S.O.R. 2016 S.I. No 721 |
| 47 | Type - IIIWiring points for call bell with1.5 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copper conductor cable as earth continuity wire and piano type Bell Push or 2 pin socketetc. complete in all respects.P.W.D.S.O.R. 2018 S.I. No.142 (C ) |
| 48 | Supply and Fixing of Sheet Steel enclouser surface / Flush Mounting Fitted with 20 Amp.2 pin and Earth metal clad scraping earth plug and socket complete in all respect P.W.D. S.O.R. 2018 S.I. No. 1031 Cat B |
| 49 | Supply and Fixing of Sheet Steel enclouser for SP/DP MCB with nutral linc and earth terminalP.W.D. S.O.R. 2018 S.I. No. 1032 Cat B |
| 50 | Supply and fixing of flush / surface mounting12 ways SPN distribution board with additinal metal door withought M.C.B. Complete in all respects.as directed at site by E / IP.W.D.S.O.R. 2018 S.I. No. 1025 ( Cat B) |
| 51 | SCHEDULEOFQUANTITIESFORFIREFIGHTING SYSTEM FOR WORKSHOP Supply & erection of ISI marked portable fire extinguishers, wall mounted type, wall brackets complete in all respect as per standard item with all accessories, delivery hose & nozzle whereever required, including fixing on walls as per the directions ofEngineer-in-charge.(MAKE : Minimax / Real Value / Firex / Safex) |
| 52 | Water ABC type. 9 Lt.capacity (IS:940) Ref no. 1131(B) |
| 53 | CO2 gas type. 4.5 kg. Capacity (IS:2878) Ref. no 1132 |
| 54 | Supply, erection and testing of ISI markedM.S. pipes (Class C - heavy duty) and specials etc. (as per IS:1239) forabove ground laying for hydrants system including transportation of materials upto the worksite, cutting the pipes to required length, edge preperation, welding, fixing / erection of pipes including specials i.e. bends, tees, reducers, flanges, expansion joints wherever required, washers, nuts, bolts etc. in proper position including all supports at maximum 3 meter spacing by 3 mm thick G.I. hangers / clamps / Tie rod supports with G.I. nuts, bolts, anchor fastner and washer for hydrant / sprinkler piping, jointing by welding, aligning the pipe line, painting with two primer coat by zinc chromate primer and two coats of synthetic enamel fire red colour, providing tapping for pressure gauges and forother instruments etc. Hydrostatic testing of system as specified, flushing & cleaning by water etc. complete as per drawings & direction of the Engineer-in-charge. The quoted rates shall also include for making holes in masonry / RCC slab, wall, chases in wall, providing sleeves in RCC wall & slabs with puddle flanges whereever required & making good the same by sealing the opening to original conditions. (MAKE : Jindal (Hissar) / Bharat / Indian Tube / Prakash) 100 NB Ref. no. 7.00 |
| 55 | Providing & fixing neoprene rubber single arch expansion joint(anti vibration bellow) as per manufacturers specifications. Tested to a pressure of 20 Kg/Cm2 including all necessary fittings complete as required. (Make : Easyflex) 100 mm dia. Ref. 5.45.1 |
| 56 | Supply & installation of ISI marked single headed 63 mm dia. gunmetal / Stainless steel Hydrant Valve, 80 mm dia flanged inlet with 63 mm female instantaneous outlet confirming to IS : 5290 on the fire wet riser/down comer, including making 80 NB pipe connection with riseralong with 100 mm dia dial pressure gauge of calibration 0-15 kg/sq cm, fixing the landing valves in proper positions, including supply of nuts, bolts, gaskets, caps, chains etc. testing the hydrant and completing the work in all respect as per directions of the Engineer-in-charge. (MAKE : Firex / Safex / Minimax / Newage)Ref. No. 10.10 |
| 57 | Supply & fixing in position ISI marked cast iron double flanged butterfly valves(PN 1.6 MPa) as per IS:13095,including transporting to worksite, supply & fixing G I nuts, G I bolts, gaskets, flanges & washers etc. including testing, Complete as per drwings & directions of the Engineer-in-charge.(MAKE : Kirloskar /Venus / IVC / Zaloto / Audco) 100 MM NBRef. no. 11.50 |
| 58 | Supply & fixing in position ISI marked cast iron double flanged dual plate type Non Return Valves (PN 1.6 Mpa) as per IS : 5312, part - I, including transportation to worksite, supply & fixing G I nuts, G I bolts, gaskets and washers etc, complete with testing as per direction oftheEngineer - in - charge.(MAKE : Kirloskar /Venus / IVC / Zaloto / Audco)100 NBRef. no. 11.50 |
| 59 | Supply, fixing, testing & commissioning of 20 mm bore and 30 meter long hose (high pressure rubber braided hose pipe as per IS:444)and hose reel suitable for 10 kg/sqcm operating pressure for first aid fire fighting conforming to IS : 884, with 180o full swing drum, fixing brackets, shut off gun metal / Stainless steel nozzle, 40 mm dia. hand lever operated isolating ball valve, connecting directly from the riser through 40 mm dia. G.I.pipe with sockets, elbows, nipples etc. including providing operating instructions on a metal plate and fixing it near hose reel. The system shall be complete in all respects as per drawings and directions of Engineer-in-charge.(MAKE : Dunlop / Goodyear / Newage)Ref no. 17.10 |
| 60 | Providing gun metal / Stainless steel ISI marked 63 mm. dia. male Instantaneous pattern short branch pipes & 20 mm dia. Nozzle as per IS : 903, suitable for 10 kg/sqcm operating pressure and suitable for interconnections to hose pipe coupling as required. (MAKE : Minimax / Firex / Safex / Newage) Ref. no.18.10 |
| 61 | Providing ISI marked RRL (IS : 636, type-A) fire hose pipe 15 meter long and 63 mm dia with ISI marked (IS : 903) gun metal / Stainless steel male and female coupling bound and rivetted to hose pipes with copper rivets and copper wire complete as required.(MAKE:Jayshree / Newage) Ref no. 16.10 |
| 62 | Providing & fixing standard carbon steel fireman axe with rubber insulated handle tested to 20000 Volts. MR |
| 63 | Providing and fixing standard fire hose cabinet door frame (1000 /mm x 2000 mm ) suitable to fit in the duct made of not less than 16 SWG MS sheethaving full fronted glass hinged door (5 mm thick clear glass) including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall or as required. The words \"FIRE HOSE\" to be painted on the box.MR |
| 64 | Supply, Fixing, Testing & Commissioning ofelectrical motor driven fire pump, suitable for automatic operation consisting of following : (TERRACE PUMP).(MAKE : Kirloskar/Mather + Platt) (a) Horizontally mounted, Centrifugal fire pumpas per IS:1520 complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 35 meter at the highest and farthest outlet at the specified flow complete with necessary strainers, 100 mm dia dial pressure gauge of calibration 0-15 kg/sq cm including bypass arrangement for periodic testing of the working of the pumpset as well as testing of automation with required length and size ofMS pipe and control valves for proper completion of work. The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head. The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately balanced dynamically. The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.(b) Squirrel cage, TEFC induction motor as per IS : 325, suitable for 415 V, 3 Phase, IP 55 protection and class \"F\" insulation, vaccume impregnated windings with heat and moisture resisting varnish for the above pump and flexible coupling with the pump. The motor shall be rated for continuous duty and shall have HP rating necessary to drive the pump at 150% of it\"s rated discharge at 65% of rated head.(c) Common bed plate of fabricated mild steel channel or cast iron type, coupling, coupling guard ets as required.(d) Suitable cement concrete pump foundation and vibration clamping arrangement as required. with foundation bolts, anti vibration pads, washers etc. (e) Pressure switchfor automatic operation of motor including necessary wiring upto control panel.(f) Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CT\"s, protective fuses, single phasing protection, dry suction cut off etc as required as per standard details.Discharge :450 liter per minute Head: 35 meterRef no. 4.20 |
| 65 | Providing and laying of ISI marked Aluminium conductor, XLPE insulated, armoured, served, sheathed Cable 1100 V grade with terminal joints by palm or pin typecable sockets (lugs), insulating with tapes, double compression type brass and nickle plated compression glands. On surface, the cable run shall be on MS cable trey or fixed on M.S. clamps etc.of suitable size or as directed by engineer-in- charge, complete in all respects. In ground the cable shall be laid at a depth of 750 mm from ground Level including a cushion of 75 mm thick. Fine river sand alround, duly protected by bricks on sides and top including excavation and back filling of soil or laid in RCC hume pipe as called for. The armouring shallbeproperly connected with the earth conductor by clampsetc. 6Sqmm 2 core Ref no. 9.1.1 |
| 66 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank 2500 litres capacity ISI : 12701 marked with cover and suitable locking arrangement and makingnecessaryholes for inlet, outlet and overflow pipes but without fittingandbasesupportfor tank. MR |
| 67 | Providing, fixing, testing and commissioning of manual call points break glass type housed in 16 SWG sheet steel housingin surface/recess including making connections with wires complete in all respects and as per specifications. The manual call point should have an indicator, which should\"blink\" in stand by condition MR |
| 68 | Providing, fixing, testing and commissioning of electronic hooters (hooters shall also be able to work as public address system sounders) housed in 16 SWG sheet steel housing suitable for wall / ceiling and surface / recess mounting including making connections with wires complete in all respects and as per specifications.MR |
| 69 | Providing, fixing, testing and commissioning of control and indicating panel for manual fire alarm systemformanual call points & hooters including stand by SMF battery & charger complete in all respect. MR |
| 70 | Supply and fixing of ISI marked (IS : 9537 part-II with latest ammendments) ERW black, stove enamelled, screwed type rigid Steel Conduit (the class of pipe shall be medium for protection against corrosion and stresses as per IS:9537 part I)in concealed / exposed system in wall, ceiling or on floor includingcutting of brick work, laying of conduitand fixing it with M.S. hooks and then plastering with cement, sand motar finished to the level, on floor the conduit shall be covered in PCC 1:2:4 for protection, including cost of threadingof conduit and providing necessary sockets, bends, tees and chuck nuts as directed at site by the engineer-in-charge with supply of all material labour and T & P required for proper completion of work. conduit being laid either in concealed system in ceiling slab or wall or on surface or under the frame of false ceiling including flexible conduits or through wooden partition including clamping arrangements as required ( Make : B.E.C. / AKG / MK )25 mm dia. conduit (Thickness 16 SWG)Ref. no. 1301 C |
| 71 | Supplying, receiving, storing, handling, fixing, wiring for fire alarm system wiring using ISI marked (IS 694) 1100 Volts grade, PVC insulated, flexible, flame retardant low smoke (FRLS), 2 x 1.5 sq. mm. copper conductor wire, drawn in existing solid / flexible conduits / casing caping including connections to the detectors, manual call points , hooters, response indicators, accessories, fire alarm control panel etc. includingtermination with bottle type copper lugs as required to complete the system.Ref no. 17.5.1 |
| 72 | Providing and fixing of self illuminated / auto glow \"EXIT\" signs printed on photoluminescentsheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site. MR |
| 73 | Fire Fighting System For Main Building Supply & erection of ISI marked portable fire extinguishers, wall mounted type, wall brackets complete in all respect as per standard item with all accessories, delivery hose & nozzle whereever required, including fixing on walls as per the directions ofEngineer-in-charge.(MAKE : Minimax / Real Value / Firex / Safex) |
| 74 | Water ABC type. 9 Lt.capacity (IS:940)Ref. no 1131 (B) |
| 75 | CO2 gas type. 4.5 kg. Capacity (IS:2878) Ref. no 1132 |
| 76 | Supply, erection and testing of ISI markedM.S. pipes (Class C - heavy duty) and specials etc. (as per IS:1239) forabove ground laying for hydrants system including transportation of materials upto the worksite, cutting the pipes to required length, edge preperation, welding, fixing / erection of pipes including specials i.e. bends, tees, reducers, flanges, expansion joints wherever required, washers, nuts, bolts etc. in proper position including all supports at maximum 3 meter spacing by 3 mm thick G.I. hangers / clamps / Tie rod supports with G.I. nuts, bolts, anchor fastner and washer for hydrant / sprinkler piping, jointing by welding, aligning the pipe line, painting with two primer coat by zinc chromate primer and two coats of synthetic enamel fire red colour, providing tapping for pressure gauges and forother instruments etc. Hydrostatic testing of system as specified, flushing & cleaning by water etc. complete as per drawings & direction of the Engineer-in-charge. The quoted rates shall also include for making holes in masonry / RCC slab, wall, chases in wall, providing sleeves in RCC wall & slabs with puddle flanges whereever required & making good the same by sealing the opening to original conditions. (MAKE : Jindal (Hissar) / Bharat / Indian Tube / Prakash) 100 NB Ref no. 7.00 |
| 77 | Providing & fixing neoprene rubber single arch expansion joint(anti vibration bellow) as per manufacturers specifications. Tested to a pressure of 20 Kg/Cm2 including all necessary fittings complete as required. (Make : Easyflex) 100 mm dia. Ref. 5.45.1 |
| 78 | Supply & installation of ISI marked single headed 63 mm dia. gunmetal / Stainless steel Hydrant Valve, 80 mm dia flanged inlet with 63 mm female instantaneous outlet confirming to IS : 5290 on the fire wet riser/down comer, including making 80 NB pipe connection with riseralong with 100 mm dia dial pressure gauge of calibration 0-15 kg/sq cm, fixing the landing valves in proper positions, including supply of nuts, bolts, gaskets, caps, chains etc. testing the hydrant and completing the work in all respect as per directions of the Engineer-in-charge. (MAKE : Firex / Safex / Minimax / Newage)Ref no. 10.10 |
| 79 | Supply & fixing in position ISI marked cast iron double flanged butterfly valves(PN 1.6 MPa) as per IS:13095,including transporting to worksite, supply & fixing G I nuts, G I bolts, gaskets, flanges & washers etc. including testing, Complete as per drwings & directions of the Engineer-in-charge.(MAKE : Kirloskar /Venus / IVC / Zaloto / Audco) 100 MM NB Ref. no. 11.50 |
| 80 | Supply & fixing in position ISI marked cast iron double flanged dual plate type Non Return Valves (PN 1.6 Mpa) as per IS : 5312, part - I, including transportation to worksite, supply & fixing G I nuts, G I bolts, gaskets and washers etc, complete with testing as per direction oftheEngineer - in - charge.(MAKE : Kirloskar /Venus / IVC / Zaloto / Audco) 100 NB Ref no. 14.50 |
| 81 | Supply, fixing, testing & commissioning of 20 mm bore and 30 meter long hose (high pressure rubber braided hose pipe as per IS:444)and hose reel suitable for 10 kg/sqcm operating pressure for first aid fire fighting conforming to IS : 884, with 180o full swing drum, fixing brackets, shut off gun metal / Stainless steel nozzle, 40 mm dia. hand lever operated isolating ball valve, connecting directly from the riser through 40 mm dia. G.I.pipe with sockets, elbows, nipples etc. including providing operating instructions on a metal plate and fixing it near hose reel. The system shall be complete in all respects as per drawings and directions of Engineer-in-charge.(MAKE : Dunlop / Goodyear / Newage) Ref no. 17.10 |
| 82 | Providing gun metal / Stainless steel ISI marked 63 mm. dia. male Instantaneous pattern short branch pipes & 20 mm dia. Nozzle as per IS : 903, suitable for 10 kg/sqcm operating pressure and suitable for interconnections to hose pipe coupling as required. (MAKE : Minimax / Firex / Safex / Newage)Ref no. 18.10 |
| 83 | Providing ISI marked RRL (IS : 636, type-A) fire hose pipe 15 meter long and 63 mm dia with ISI marked (IS : 903) gun metal / Stainless steel male and female coupling bound and rivetted to hose pipes with copper rivets and copper wire complete as required.(MAKE:Jayshree / Newage)Ref no. 16.10 |
| 84 | Providing & fixing standard carbon steel fireman axe with rubber insulated handle tested to 20000 Volts.MR |
| 85 | Providing and fixing standard fire hose cabinet door frame (1000 /mm x 2000 mm ) suitable to fit in the duct made of not less than 16 SWG MS sheethaving full fronted glass hinged door (5 mm thick clear glass) including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall or as required. The words \"FIRE HOSE\" to be painted on the box. MR |
| 86 | Supply, Fixing, Testing & Commissioning ofelectrical motor driven fire pump, suitable for automatic operation consisting of following : (TERRACE PUMP).(MAKE : Kirloskar/Mather + Platt) (a) Horizontally mounted, Centrifugal fire pumpas per IS:1520 complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 35 meter at the highest and farthest outlet at the specified flow complete with necessary strainers, 100 mm dia dial pressure gauge of calibration 0-15 kg/sq cm including bypass arrangement for periodic testing of the working of the pumpset as well as testing of automation with required length and size ofMS pipe and control valves for proper completion of work. The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head. The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately balanced dynamically. The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.(b) Squirrel cage, TEFC induction motor as per IS : 325, suitable for 415 V, 3 Phase, IP 55 protection and class \"F\" insulation, vaccume impregnated windings with heat and moisture resisting varnish for the above pump and flexible coupling with the pump. The motor shall be rated for continuous duty and shall have HP rating necessary to drive the pump at 150% of it\"s rated discharge at 65% of rated head.(c) Common bed plate of fabricated mild steel channel or cast iron type, coupling, coupling guard ets as required.(d) Suitable cement concrete pump foundation and vibration clamping arrangement as required. with foundation bolts, anti vibration pads, washers etc. (e) Pressure switchfor automatic operation of motor including necessary wiring upto control panel.(f) Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CT\"s, protective fuses, single phasing protection, dry suction cut off etc as required as per standard details.Discharge :450 liter per minute Ref 4.20 Head: 35 meter |
| 87 | Providing and laying 6 sqmm2 core of ISI marked Aluminium conductor, XLPE insulated, armoured, served, sheathed Cable 1100 V grade with terminal joints by palm or pin typecable sockets (lugs), insulating with tapes, double compression type brass and nickle plated compression glands. On surface, the cable run shall be on MS cable trey or fixed on M.S. clamps etc.of suitable size or as directed by engineer-in- charge, complete in all respects. In ground the cable shall be laid at a depth of 750 mm from ground Level including a cushion of 75 mm thick. Fine river sand alround, duly protected by bricks on sides and top including excavation and back filling of soil or laid in RCC hume pipe as called for. The armouring shallbeproperly connected with the earth conductor by clampsetc. Ref no. 9.1.1 |
| 88 | Providing and placing on terrace (at all floor levels) polyethylene 2500 litres capacitywater storage tank ISI : 12701 marked with cover and suitable locking arrangement and makingnecessaryholes for inlet, outlet and overflow pipes but without fittingandbasesupportfor tank.MR |
| 89 | Providing, fixing, testing and commissioning of manual call points break glass type housed in 16 SWG sheet steel housingin surface/recess including making connections with wires complete in all respects and as per specifications. The manual call point should have an indicator, which should\"blink\" in stand by condition.MR |
| 90 | Providing, fixing, testing and commissioning of electronic hooters (hooters shall also be able to work as public address system sounders) housed in 16 SWG sheet steel housing suitable for wall / ceiling and surface / recess mounting including making connections with wires complete in all respects and as per specifications. MR |
| 91 | Providing, fixing, testing and commissioning of control and indicating panel for manual fire alarm systemformanual call points & hooters including stand by SMF battery & charger complete in all respect. MR |
| 92 | Supply and fixing of ISI marked (IS : 9537 part-II with latest ammendments) ERW black, stove enamelled, screwed type rigid Steel Conduit (the class of pipe shall be medium for protection against corrosion and stresses as per IS:9537 part I)in concealed / exposed system in wall, ceiling or on floor includingcutting of brick work, laying of conduitand fixing it with M.S. hooks and then plastering with cement, sand motar finished to the level, on floor the conduit shall be covered in PCC 1:2:4 for protection, including cost of threadingof conduit and providing necessary sockets, bends, tees and chuck nuts as directed at site by the engineer-in-charge with supply of all material labour and T & P required for proper completion of work. conduit being laid either in concealed system in ceiling slab or wall or on surface or under the frame of false ceiling including flexible conduits or through wooden partition including clamping arrangements as required ( Make : B.E.C. / AKG / MK )20 mm dia. conduit (Thickness 14 SWG) Ref no. 1301 C |
| 93 | Supplying, receiving, storing, handling, fixing, wiring for fire alarm system wiring using ISI marked (IS 694) 1100 Volts grade, PVC insulated, flexible, flame retardant low smoke (FRLS), 2 x 1.5 sq. mm. copper conductor wire, drawn in existing solid / flexible conduits / casing caping including connections to the detectors, manual call points , hooters, response indicators, accessories, fire alarm control panel etc. includingtermination with bottle type copper lugs as required to complete the system.Ref no. 17.5.1 |
| 94 | Providing and fixing of self illuminated / auto glow \"EXIT\" signs printed on photoluminescentsheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.MR |
| 95 | Construction of Tube well and instalation of submersible pump (120mtr. Depth ) |
| 96 | Transportation of mini drilling Rig machine with camp equipage to site |
| 97 | Drilling of 350mm dia bore hole with lowering of tube well assembly |
| 98 | Supply & fixing of 200mm dia plain rigid PVC casing pipe (10kg. Per sqcm. Presure rating) and accessories. |
| 99 | Supply & fixing of 150mm dia plain rigid PVC slotted pipe and Accessories . |
| 100 | Supply & fixing of nylon jali around the slotted pipes complete as required. |
| 101 | Providing and packing of coarse sand/pea gravel around the pipe. |
| 102 | Supply of submersible pump of make KSB 5.0 HP. With control pannel support wire etc. complete. |
| 103 | Providing 3 core 2.5 sqmm PVC insulated copper conductor submersible cable (from pump pannel to submersible p[ump) |
| 104 | Providing & fixing 65mm dia GI pipe complete with fitting and clamp including cutting and making good the walls etc. (from submersible pump to ground level) DSR 18.12.7 |
| 105 | Providing & fixing 65mm dia brass gate valve with CI wheel of approved quality. DSR 18.17.5 |
| 106 | Supply & fixing of tube well accessories i.e. well cap, clips, clamp etc. to complete the job in all respect |
| 107 | Fixing, testing & commissioning for erection and lowering of submersible pump, 65mm dia GI column pipe, 3 core 2.5sqmm submersible copper cable upto the control pannel, supporting clamps, cable clips pressure gauge, connection line and all other accessories required for the proper completion of the work. |
| 108 | Testing and development of tube well. |
| 109 | Supply of Aquas make electronic Chlorinator of 6LPH capacity complete accessories and 100 Ltr, PVC solution tank. |
| 110 | Installation charges (1/2\" socket fixed in pipe line to provide by the department, out side Lucknow |
| 111 | External Electrification and Street Light workSupply and erection 410 SP-32 of 9.00 Mtrs. Long S.T. pole confiring to the I.S.S. No IS2678-1960, IS 1343-1960 and 456-1965 with 1/6th over all length of pole grouted with 1:4:8 cement concrete (1 cement, 4 finesand and 8 OBB of 40 mm nominal size ) including plinthing with 2 mm nominal size stone grit 10 cm below the G.L. and 30 cm above the G.L. and plastering with 1:4 cement sand mortar painting and numbering of pole and making strip with enamel paint complete with all materials, labour and T&P etc. and also including the cartage of pole to site of work (As per specification No- 1.1 to 1.5.4)P.W.D.S.O.R.2018 S.I.No.613 |
| 112 | S/F ofM.S. clamp for 410 SP-32, 9.00 Mtrs long L.T. insulator suitable for S.T. pole made of 50x 6mm M.S. flat making necessary holes suitable for bolts, nut and washer duly painted with approved paint including the cost of material, labour and T&P etc. Required for proper completion of work. (As per specification No 1.2 to 1.5.4) |
| 113 | S/F of 410 SP-32, 9.00 Mtrs long earth clampsuitable for following types of supports- (As per specification No 24) |
| 114 | S/F of G.I. shackle strips of 355 x 40 x 4 mm size including holes for shackle insulator\"s pins and bolts nuts etc including the cost of material, labour and T&P required for proper completion of work.(As per specification No-6) |
| 115 | S/F of shackle insulator 100 x 115 mm size with M.S. Bolt nut and washer etc. complete with all material,labour and T&P required for proper completion of work.(As per specification No-7) |
| 116 | Supplying stringing and sagging over head L.t. lines with A.C.S.R. conductors like Dog, Raccoon, Rabbit or weasel confiring to the relevant I.S. specification of S.T. poles/P.C.C. poles/Rails/Joist, service brackets including the cost of all material, labour T&P required for proper completion of work.(As per specification No-13 to 13.3) P.W.D.S.O.R.2018 S.I.No.627 |
| 117 | Rabbit |
| 118 | Weasel |
| 119 | Supply and erection of overhead lines with 6SWG G.I. wire on S.T. pole required for earth wire with binding etc. including the cost of allmaterial, labour and T&P required for proper completion of work as pe direction of E/IP.W.D.S.O.R.2018 S.I.No.628 |
| 120 | Supply and fixing of hexagonal guard of6 SWG G.I. wire with binding including the cost of allmaterial, labour and T&P required for proper completion of work as pe direction of E/I.(As per specification No-14) |
| 121 | Supply and erection of stay set atleast 3.5 mters away from the supports or as per actual site requirement complete with G.I. 16mmx1.8Meters long stayrod 152x152x6mm G.I. anchor plate, thimble, stay clamps stay insulator 75x125 mm and 7/10 SWG, G.S. stay wire duly grouted in 1:4:8 cement concrete ( 1 cement, 4 fine sand and 8 OBB 40 mm nominal size) includingcost of allmaterial, labour and T&P required for proper completion of work as pe direction of E/I.(As per specification No-9 |
| 122 | Making suitable earthing of S.T. pole with 2.5 Mtrs Long 20 mm dia M.S. rod with 7/16 SWG, G.S. wire in 15 mm dia 2.0 Mtrs Long G.I. pipe duly clamped with three No clamps and binding on poles including cost of all material,labour and T&P required for proper completion of work.(As per specification No-12) |
| 123 | Supply and fixing of H.T./L.T. jumpering and connections on double pole/four pole. Lighting arrestor and transformer. The rates include the cost of all material, labour and T&P etc. required for proper completion of work as per specification and direction of E/I. |
| 124 | S/F of 80 mm dia (6.98Kg/M) of G.I. pipe \"B\" calss for cable clamped with supports by 3 Nos clamp made of 20x3 mm MS flat and suitable size of nut, bolt and wadher required for proper completion of work as per direction of E/I. |
| 125 | Supply & fixing ofLEDstreet lightfittinghaving powder coated die cast Aluminnium body and Diffuser with driver set suitable or 52 watt to 72 watt conforming to IP 65 and above protection complete in all respect PWD sor 2018 S.I. No. 1422 |
| 126 | S/F of 63 amp.415 V metal clad TPN HRC type switch fuse unit complete with HRC fuse on Angle Iron FramePWD SOR 2018 S.I. No. 316 Cat - B |
| 127 | S F of 2 x 4 sq. mm weather proof twine core Al. cable |
| 128 | Supply & laying of240 Sq.mm 3 ½ corealuminium conductor PVCinsulatedarmoured served sheathed cables 1100 Volts grateata depthofbelowground level over a cushion of 75mm. below groundlevel over a cushion of 75mm. thicksand alround and protected with burnt bricks on sides and on top.On surface the cable run shallbefixedonM.S. clamps etc. ofsuitablesizeorasdirectedby the Engineer-incharge, complete in all respects. The armouringof the cable shall be properly connected with the earth conductor by clamps etc. PWD SOR 2018S.I. 501 |