Special Repairs To Or Md Accn Bldg No 229 1 To 4 At Allenby Line Md Accn Of Hq Coy 1 Eme Centre Improvement And Addn Altn Of Sewage Line In S Coy 3 Trg Bn 1 Eme Centre Spl Repairs To Replacements Of Roof Asbestos Cement Sheet With Galvalume Sheet Of T 5, secunderabad-Telangana

Military Engineer Services-MES has published Special Repairs To Or Md Accn Bldg No 229 1 To 4 At Allenby Line Md Accn Of Hq Coy 1 Eme Centre Improvement And Addn Altn Of Sewage Line In S Coy 3 Trg Bn 1 Eme Centre Spl Repairs To Replacements Of Roof Asbestos Cement Sheet With Galvalume Sheet Of T 5. Submission Date for this Tender is 21-06-2022. Sewerage Construction Tenders in secunderabad Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

32448410
Corrigendum : Special Repairs To Or Md Accn Bldg No 229 1 To 4 At Allenby Line Md Accn Of Hq Coy 1 Eme Centre Improvement And Addn Altn Of Sewage Line In S Coy 3 Trg Bn 1 Eme Centre Spl Repairs To Replacements Of Roof Asbestos Cement Sheet With Galvalume Sheet Of T 5
Open Tender
Indian
Telangana
secunderabad
21-06-2022

Tender Details

Special Repairs To Or Md Accn Bldg No 229 1 To 4 At Allenby Line Md Accn Of Hq Coy 1 Eme Centre Improvement And Addn Altn Of Sewage Line In S Coy 3 Trg Bn 1 Eme Centre Spl Repairs To Replacements Of Roof Asbestos Cement Sheet With Galvalume Sheet Of T 5

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Jun-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-06-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 78560.0 /-
Tender Value
INR 39.28 Lakhs /-

BOQ Items

Name of Work: SPL REPAIRS TO OR MD ACCN BLDG NO 229 (1 TO 4) AT ALLENBY LINE MD ACCN OF HQ COY, 1 EME CENTRE, IMPROVEMENT AND ADDN/ALTN OF SEWAGE LINE IN S COY, 3 TRG BN, 1 EME CENTRE, SPL REPAIRS TO REPLACEMENTS OF ROOF ASBESTOS CEMENT SHEET WITH GALVALUME SHEET OF T-5, T-6 & T-11 OR LIVING AT 76 INF BDE CAMP AND PROVISION OF SOAKAGE WELL AT BLDG NO J-29 (OFFR MD ACCN) ALLENBY LINES UNDER GE (NORTH) SECUNDERABAD
Sl. No. Item Description
1Dismantling of asbestos cement sheet (corrugated or semi corrugated)/Plain or corrugated steel sheetingin roof covering complete all as specified and as directed.
2Supply and fix pre-painted galvalume aluminium zinc coating galvanised based corrugated steel sheet of 0.50 mm thick of approved colour having tensile strength of 550 Mpa asroof covering/cladding to wall fixed with self tappingscrews complete all as specified and as directed.
3Supply and fix pre-painted galvalume aluminium zinc coating galvanised based plain steel/corrugated sheet of 0.50 mm thick of approved colour having tensile strength of 550 Mpa as ridge, gutters fixed with self tappingscrews complete all as specified and as directed.
4Dismantling timber Scantling framed work in fillets, rails, posts, rafters, purlins, etc. under 40 Sqcm in section complete all as specified and as directed.
5Dismantling timber Scantling framed work 40 Sqcm and over in section, in any position and removing and depositto AGE B/R NO -1 store complete all as specified and as directed.
6Supply and fixhand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling or riveting etc and similar work confirming to Fe-410-0 of Fe-310-0 of Gde E-165complete all as specified and as directed.
7Supply and fix rolled mild steel sections of Fe 410-W (GDE E-250) QUALITY “A” frame work as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and as directed.
8Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets or frame workcomplete all as specified and as directed.
9S & FE Grid suspended false ceiling grid system of size 600 x 600mm with main runner 39x29.7x0.60mm cross tee 29x24.7x0.60mm and wall angle 22.2x22.2x0.50mm ceiling suspended with 2 to 2.5 mm dia GI wire hanger fixed to purlin / truss etc complete (Main runner, cross tee, wall angle of MS galvanised with PPCGS) over the grid providing 4mm thick HPSC pre primed self designer texture non asbestos fibre cement building board fixed to frames etc complete all as specified and as directed.
10Demolition cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and as directed.
11M&L for 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth sealed with sealing compound grade ‘A’ complete all as complete all as specified and as directed.
12Dismantling stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and as directed.
13M&L for 20-25 mm thick machine cut Polished kotastone as in treads of staircaselaying down and jointed with grey cement slurrymixed with pigment to match the shade of the slab including rubbing and polishing completeover bedding layer of 15mm thick in CM 1:6complete all as specified and as directed.
14M&L for 20-25 mm thick machine cut Polished kotastone as in skirting / riser of staircaselaying down and jointed with grey cement slurrymixed with pigment to match the shade of the slab including rubbing and polishing complete over backing coat of 10mm thick in CM 1:4 complete all as specified and as directed.
15M & L for Machine cut cudappa stone slab 20-25mm thick over 20mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
16Dismantling floor hearth or wall tilingincluding cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
17Material and labour for glazed ceramic coloured wall tiles of approved colour of size 350x 250x 7/ 450x300x7 mm thick on vertical surfaces as in dado/wall set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 10 mm thick backing coat in cement mortar 1:4 complete all as specified and as directed.
18Material and labour for Non skid coloured ceramic tiles of size exceeding 0.06 square metre but not exceeding 0.11 square metre of 7 to 8mm thick set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including cement screed bed of cement mortar 1:6 of 15 mm thickcomplete all as specified and as directed.
19Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles including disposal of the rubbish out off the premises complete all as specified and as directed.
20Material and labour forbrick work with fly ash bricks old size,straight or curved on plan exceeding 6.0 metre mean radiusbuilt in cement mortar 1:6 complete all as specified and as directed
21Material and labour forbrick work with fly ash bricks old size,straight or curved on plan exceeding 6.0 metre mean radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
22M&L for PCC 1:3:6 type B1 (using 20mm graded aggregate) in copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating as directed chamfered necessary form work complete all as specified and as directed.
23Demolition of reinforced concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed.
24M & L for providing precast cement concrete type B1 1:2:4 (20mm stone aggregate)in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face set in cement mortar 1:4 complete all as specified and as directed.
25M&L reinforced cement concrete(nominal mix) type B1 1:2:4 (using 20 mm graded aggregate) as in RCC bandssupported on walls, beams and columns in floors,roof, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
26M&L for formwork to sides and soffits of floor or roof beams, beam haunhings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs,etc., also splays between floors and beams etc as in rough finished flat surfaces of concrete complete all as specified and as directed.
27M&L for mild steel TMT bars 10mm dia and over including all cutting bending, binding, cranking placing & binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and as directed.
28M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders etc., including all cutting bending, binding, cranking placing & binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and as directed.
29Taking down chowkats or frames with shutters (without taking off shutters from frames) of size exceeding 1.5 square metre but not exceeding 4 square metre each complete all as specified and as directed.
30Taking down chowkats or frames with shutters (without taking off shutters from frames) of size not exceeding 1.5 square metreeach complete all as specified and as directed.
31Taking down shutter of any description exceeding 1 Sqm and not exceeding 2 Sqm each complete all as specified and as directed.
32S&F 125 x 60 mmpressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed.
33S & F pressed steel frame of size 105 x 60mm for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed.
34M&L for PCC bed block in 1:3:6 type C1 using 20mm graded stone aggregate for back filling of steel chowkatws complete all as specified and as directed.
35Cutting holes in brick wall built in cement mortar for inserting hold fast and making good the disturbed portion in cement mortar 1:3 depth of embeded portion exc half brick & not exceeding one brick complete all as specified and as directed.
36S&F bands, straps, supports or stays for rain water, hooks (stay) heavy for large gates, hook and pintle hinges clamps, hold fastswall ties, hooks for hanging fans and similar small articles Fe-410-0 or Fe-310-0 complete all as specifed and as directed.
37S & F 35 mm thick factory made second class hardwood,plain framed panelled shutters (any number ofpanel) with panels of timber flat on both sides(feather edged) or of veneered particle board medium density wood particle board with commercial veneering on both faces complete all as specified and as directed.
38S & F 30 mm 1st class hard wood factory made glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars) edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of member of shutter as specified in SSR Part-I section 8 clause 8.24(a) etc., complete all as specified and as directed.
39Supply and fix steel window with side hung double shutters of gauzed shutter openableinside and glazed shutter openable outside with projectingtype hinges, steel handles and steel peg stay with glazing bars dovetailed or welded and ventilator fixed type complete all as specified and as directed.
40M&L for Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe290 Gde E-165 complete all as specified and as directed.
41Supply and fix in 4 mm thick sheet glass, ordinary quality and glazing with oil putty and glazing clips in metal frame and second class hard wood beading in suitable size for wooden frames of any size complete all as specified and as directed.
42Supply and fix in4 mm thick figured glass, pin head type and glazing with oil putty and glazing clips in metal frame and second class hard wood beading in suitable size for wooden frames not exceeding 0.5 sqm in each pane complete all as specified and as directed.
43Supply and fix Solid PVC door frame of size 50 x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube, all as specified and shown in Section 8 of MES Schedule Part-II 2020 complete all as specified and as directed.
44Supply and fix Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawings given in Section 8 of MES Schedule Part-II 2020 as applicable complete all as specified and as directed.
45S&F 150 mm extruded aluminium alloy handle, fabricated type, anodised complete all as specified and as directed.
46S&F 150mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed.
47S&F 100 butt hinges extruded aluminium alloy with galvanised mild steel hinges complete all as specified and as directed.
48S&F MS sliding door bolts plate type stove enamelled black, with brignt bolt not less than 12mm dia with and including a minimum of 6 Nos bolt and nuts, four on bolt plate and two on staple plate of 300mm length of bolt complete all as specified and as directed.
49S&F for Mild steel 300 mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
50S&F in repair aluminium powder coated (fancy type) tubular curtain rod, 20mm dia, complete all as specified and as directed.
51S&F in repair bracket aluminium powder coated (fancy type) for 20 mm dia tubular curtain rod(for item above) complete all as specified and as directed.
52S&Ffor Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified and as directed.
53S&F in repairs vitreous china wash basin, white, flat back, size 580mm X 450mm including CI brackets, 32mm dia brass chromium plated waste fittingswith long screwed shanks and fly nuts flanged end bedded in red lead cement and other end fixed with & including cutting for & pinning in end of brackets and 15mm bore pillar tap, cast copper alloy fancy type chromium plated, screwed down high pressure complete all as specified and as directed.
54S & F repairs 600mmx 450mm bevelled edge miirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.
55Supply & fix in repairs Vitreous China Squatting pan, "Orissa" pattern, size 580 x 440 mm white with integral foot rests including connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including cement concrete including making good to floor complete all as specified and as directed.
56S & F in repairs shelf of PTMT fixed with and including CP plated brass screws and wooden/plastic cleats. (Minimum weight 105 gms) complete all as specified and as directed.
57S & F in repairs Towel rail 600mm long of PTMT fixed with and including CP brass screws and wooden/plastic cleats. (Minimum weight 190 gms) complete all as specified and as directed.
58S&F in repairschromium plated shower roses 125mm size with or without swivel joint including fixing to steel pipe or union etc., complete all as specified and directed.
59S&F in stainles steel sink with drainage board,1 mm thick sheet of steel grade AISI 304 for kitchen or laboratory, with plug, waste pipe, washers and wastes including bedding in cement mortar to dwarf wall or including fixing CI cantilever bracket, connecting union to pipeetc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm etc complete all as specified and directed.
60S&F stainless steel plate rack, wall mounted of size 750mm X 900mm X 200 mm of approved quality made of 1.00mm thick stainless steelfor kitchen with necessary fixing material complete all as specified and as directed.
61Dismantling water tanks exceeding 250 and not exceeding 500 litres and removing to store complete all as specified and as directed.
62S&F rotational moulded polyethyiene water storage tanks (cylindrical vertical with closed top) of 500 liters capacity complete all as specified and as directed.
63S & F in repairs 20 mmBall valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight20mm-210 gms) complete all as specified and as directed.
64S & F in repairs for 20mm gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
65Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
66S&FTubes, ‘medium grade’ galvanised, 15mm bore with all fitting and fixed complete to walls and ceilings or laid in floorsetccompleteall as specified and as directed.
67Refixing old steel tubing of 15 mm bore and connections in new or old position (walls, ceilings, floors etc.,) complete all as specified and as directed.
68Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed.
69Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) complete all as specified and as directed.
70S&FTubes, ‘medium grade’ galvanised, 20mm bore with all fitting and fixed complete to walls and ceilings or laid in floorsetccompleteall as specified and as directed.
71S&F in repairs CPbib tap 15mm bore fancy type with crutch or butterfly handle, screwedfor iron pipe or for unions and fixed complete all as specified and as directed.
72Supply and fixed in repairs stop valve / angle cockfancy type cast copper alloy chromium plated with capstan head serewed down for 15 mm dia iron pipe complete all as specified and as directed..
73S&F PVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4) & including removing old trap and fixing ofstainless steel grating in round shape etc complete all as specified and as directed.
74S & F in repairs PVC 10 ltrs capacity symphonic action type low level flushing cistern including flush pipe, cantilever brackets incluiding taking down existing cistern etc complete all as specified and as directed.
75S&F PVC connection, 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
76S & F 110 mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches including taking down of old pipes complete all as specified and as directed.
77Supply & fixing PVC (SWR) junction single (single T) equal or unequal 110mm dia with access doors complete all as specified and as directed.
78S&F 110mm dia vent cowl PVC (SWR) complete all as specified and as directed.
79S & F 110mm bore PVC (SWR) plain bends, any radius complete all as specified and as directed.
80Taking down cement plaster of any description and thickness on brickwallsincluding racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
81Material and labour for rendering 12 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4without using extra cement complete all as specified and as directed.
82M & L for rendering 15 mm thick in two coats, 10 mm thick in cement plaster 1:6 and 5 mm thick in cement plaster 1:4 mixed with integral water proofing compound as per manufacturers instructions, on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement all as specified and as directed. Note: Water proofing compound shall be measured and paid seperately.
83Supply only integral water proofing compound complete all as specified and as directed.
84M & L for preparing newly plasterd wall surfaces and applying two coats of distemper oil emulsion over 3 mm thick wall care putty and a coat of primer using chalk whiting etc complete all as specified and as directed.
85M & L for preparing newly plasterd wall surfaces and applying three coats of white wash complete all as specified and as directed.
86M & L for complete removal of existing treatment ofwall and applying two coats of distemper oil emulsion on walls over 3mm thick wall care putty complete all as specified and directed.
87M & L for preparing the old plastered or unplastereddecorated surfaces of walls and applying two coats of white wash complete all as specified and as directed.
88M&L for new or previously untreated steel surfacesof any description, over 10 cm in width or girth, not otherwise described and apply two coats of synthetic enamel paint (ordinary tint)including priming with red oxide, zinc chrome complete all as specified and as directed.
89M&L for prepation of new or previously untreated wooden surfaces of any description, over 10 cm in width or girth not otherwise describedapplying two coats of syntheticenamel paint including one coat of pink primer etc complete all as specified and directed.
90M & L for preparation of old paintedwooden surfaces of any description over 10 centimetre width or girthand applying one coat of synthetic enamel paintcomplete all as specified and as directed.
91M&L for preparing old painted surfaces of walls and applying two coats of weather proof paint on external surfaces of walls and celing, including necessary scaffolding and saftey precations to the work complete all as specified and as directed. Make : Apex from Asian Paints orequivalent in All Guard from Berger,Weather Shield Max Exterior Acrylic from ICI Dulux
92Demolition of Concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed..
93M&L for 75 mm thick plain cement concrete 1:4:8 mix,type D2 (using 40 mm graded stone aggregates) as in subbase to floor complete all as specified and as directed.
94M&L for designer rubber moulded chequerred cement concrete tileswith mixture of greyand white cemetn in equal porportions with pigments of size 300 x 300 x 22mm or 250 x 250 x 22mm thick and set and pointed in neat cement slurry in floors over a screed bed or bedding layer in CM 1:6, 15mm thick for laying floor finishes etc complete all as specified and as directed.
95Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
96Dismantling mangalore pattern roofing tiles single layer including ridge tiles laid, bedded in cement mortar etc complete all as specified and as directed.
97Dismantling battens for tiles any size exceeding 15cm in spacing complete all as specified and as directed.
98S & Frepairs to snap grid ceiling with 4 mm thick E Board of approved size 60cm x 60 cm supported and including ceiling alluminium alloy anodized angle 25x25x1.5mm at edge and tee section 25 x 38 x 1.5mm at edges and edges placed both way at spacing 60 cm center to center incl necessary aluminium alloy anodized cleats and 3mm dia GI wire suspender fixed to ceiling not exceeding 120 cm center to center both ways incl two coat of oil bound distember complete all as specified and as directed. Make : Everest (Classic) /Armstrong / Saint Gobain as approved by GE.
99M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surface finished even and smoothcomplete all as specified and as directed.
100Material and labour for preparation of newly plastered surfaces of walls and applying 2 coats of apexultima weather proofpaint over a coat of apex ultima primer including preparation of surfaces complete all as specified and directed. Make : Apex from Asian Paints orequivalent in All Guard from Berger,Weather Shield Max Exterior Acrylic from ICI Dulux
101M&L Complete removal of existingtreatment on walls and applying 2 coats of apexultima weather proofpaint over a coat of apex ultima primer including preparation of surfaces complete all as specified and directed. Make : Apex from Asian Paints orequivalent in All Guard from Berger,Weather Shield Max Exterior Acrylic from ICI Dulux
102S&F Rolled mild steelin Roof trusses (framed) main and cross beams andconnecting plates, hip and jack rafters; purlins where connected to common rafters and running rails and guides fixed with angle cleats or other connecting plates etc., of Fe 410-W (Gde-E-250) quality Acomplete all as specified and as directed. Note: The ISMB"s have to be inserted in wall by replacing damaged existing rafters as in old madras terrace roof including necessary precautionary measures as in supports etc. This aspect shall be taken into consideration while quoting the unit rate.
103S&F Rolled mild steel in joist channel, angle or tee sections, fixed independently without connecting plates, etc., (cut to ordinary lenghts i.e within 20mm of the length indicated of Fe 410-W ( Gde-E-250) quality A and including necessary precautionary measures as in supports etc., complete all as specified and directed.
104S&F Plates (plain or chequered)channels, square cut or notched(ordinary and counter sunk)forming holes, without anyattachment etc.Roof strusses (framed) andconnecting plates, etc.,including necessary precautionary measures as in supports etc., complete all as specified and as directed.
105S&Fwind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 etc complete all as specified and as directed.
106M&L for Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in CM 1:6 etc: complete all as specified and as directed.
107M&L for Rendering 10 mm thk in CM (1:4) as in backing coat of cement plaster for laying of wall tiles etc: complete all as specified and as directed.
108M&L for Non-skidceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqmin floorsetc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, etc complete all as specified and as directed.
109M&L for Non-skidceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqmin skirting / dado etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match etc., complete all as specified and asdirected.
110Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 m dia x 4.5 m effective depth as per drawing No TD/ST/748, Sheet No 1/1 dated 22 Jan 2011 and complete all as specified and as directed.
111Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in Soft/Loose soil, complete all as specified and directed.
112M&L PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation complete all as specified and as directed.
113Returning filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed.
114Removing excavated material/debris out side of MOD land and depositing where directed complete all as specified and as directed.
115M&L for PCC 1:2:4 type B1, using 20mm graded stone aggregate as surface channels and drains including fair finishing complete all as specified and directed.
116M&L for 15mm thick rendering over brick or concrete surfaces in cement mortar 1:4 finished smooth and even without using extra cement complete all as specified and as directed.
117M&L for providing precast cement concrete 1:2:4 type B-1 in cover slabs (for manholes etc.,) and similar articles with plain faces inlcuding chamfers weatherings, throating etc., and setting in cement mortar 1:4 complete all as specified and as directed.
118S&F TMT bars 6mm dia and over upto and including 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed..
119Demolition ofreinforced cement concrete in ground floors and pavings not exceeding 15 centimetre thickness (below or above ground level) complete all as specified and as directed.
120Supply and fix in repairs 110 mm dia PVC (SWR) bends with oval access door of any radius complete all as specified and as directed.
121Material and labour for rendering 15 mm thick onbrick masonry surfaces or concrete surfaces built in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and as directed.
122Excavation in trenches not exceeding 1.5 metres wide and not exceeding 1.5 metres deep for laying of drain pipes etc., for manholes and getting out in hard and dense soil complete all as specified and as directed.
123Excavation in trenches not exceeding 1.5 metres wide and not exceeding 1.5 metres deep for laying of drain pipes etc., for manholes and getting out in road cutting complete all as specified and as directed.
124Excavation in trenches not exceeding 1.5 metres wide and exceeding 1.5 metres deep but not exceeding 3.0 metres deep for laying of drain pipes etc., for manholes and getting out in hard and dense soil complete all as specified and as directed.
125Demolition and breaking up drain pipes NP3 (salt glazed ware AC or reinforced concrete) set in cement mortar 150mm dia complete all as specified and as directed.
126Demolition and breaking up drain pipes NP3 (salt glazed ware AC or reinforced concrete) set in cement mortar 200 mm dia complete all as specified and as directed.
127Material and labour for reinforced concrete pipes, class NP3 150 mm bore laid in trenches with one collar per length and jointed with cement joints complete all as specified and as directed.
128Material and labour for reinforced concrete pipes, class NP3 200 mm bore laid in trenches with one collar per length and jointed with cement joints complete all as specified and as directed.
129Material and labour for reinforced concrete pipes, class NP3 300 mm bore laid in trenches with one collar per length and jointed with cement joints complete all as specified and as directed.
130Material and labour for concrete bed to drain pipes of 150 mm dia including packing under and haunching against the sides of pipes with concrete, after they are laid including testing in plain cement concrete 1:3:6, type C2 using 40 mm graded aggregate with necessary form work complete all as specified and as directed.
131Material and labour for concrete bed to drain pipes of 200 mm dia including packing under and haunching against the sides of pipes with concrete, after they are laid including testing in plain cement concrete 1:3:6, type C2 using 40 mm graded aggregate with necessary form work complete all as specified and as directed.
132Material and labour for concrete bed to drain pipes of 300 mm dia including packing under and haunching against the sides of pipes with concrete after they are laid including testing in plain cement concrete 1:3:6, type C2 using 40 mm graded aggregate with necessary form work complete all as specified and as directed.
133Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 100 mm dia of pipe complete all as specified and as directed.
134Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 150 mm dia of pipe complete all as specified and as directed.
135Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 200 mm dia of pipe complete all as specified and as directed.
136Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power /two way/bell etc., on TW batten/conduit includingremovalof batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and seperating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed.
137Material and labour for point wiring complete with stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLS conforming to IS - 694 multistranded drawn through and including rigid 20mm dia PVC medium grade conduit and conduit accessories duly ISI markedon surface etc., with new sunk type pressed steel terminal boxes suitable forswitches duly painted with two coats of red oxide zinc chrome primer with suitable hylam sheet cover of suitable size for mounting of switches, regulators and drawing continuous earth wire with one run of 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLSconforming to IS - 694 multistranded copper conductor as earth wire and connecting to common earth dolly and making good the disturbed wall surfaces to match with the existing surfaces complete all as specified and as directed. for the following :- (a) One light point/Bell point controlled by one, one way switch 5 amps, SP
138All as per item No. 137 above but One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and as directed.
139All as per item No. 137 above but One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and as directed.
140All as per item No. 137 above but One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed.
141All as per item No. 137 above but using2.5 Sqmm single core copper conductor cable of multistranded PVC insulated unsheathed 1100 Volts grade for 3 Pin 15 Amps switch socket combinationpoint on independent boardincluding running of 1.5 Sq mm copper conductorPVC insulated cable as earth continuity conductor complete all as specified and as directed.
142S & F switch piano single pole flush type 5 amps, 230 volts complete all as specified and as directed.
143S & F switch socket combination 2 in 1 flush type multipurpose 3/5 pin 5 amps,230 Volts complete all as specified and as directed.
144S & F switch socket combination 2 in 1 multipurpose 6 pin 15 amps flush type complete all as specified and as directed.
145S & F Bell push switch 5 amps flush type complete all as specified and as directed.
146S & F electronic ceiling fan regulator stepped typeheavy duty suitable to work on 230 volts complete all as specified and as directed.
147S & F lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with wooden round blocks complete all as specified and as directed.
148S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed.
149S & F Call bell AC 230 volts single phase complete all as specified and as directed.
150S & F LEDtube light fitting 20 Watts , 230 volts, box type, epoxy powder coaded CRCA sheet huusing with reflector cover channel, with electronicdrive, bipin holders, connector block, internally pre wired etc with necessary mounting arrangements including all accessories with new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make : Havells cat No-REGALBATTENT8UPTO1X 22W SSBSWH incl Tube Rod cat No-PHOTONULTRA 2.01213T8SSTL20WLED 865SPC, Wipro cat No WI0921208 incl Tube Rod LL13-181-65SE, PHILIPS CAT NO TMC501P1xT-LED22WP3241 incl tube rod 20w.
151S & F security LED Light fitting 1x35 Watt complete with Bracket made out GI pipe med grade 40mm of L Shape 1.5 Mtr long incl clamps and nuts botls etc., complete all as specified and as directed. Make: Havells Cat No. ENDCITYLIPLAT+ SL35WLEDT57SAYSBODCWDSPO/ Wipro Cat No. LR13-501-XXX- 57-XX/Philips Cat No. BRP046LED 36CWMRS1PSU GR
152S & Fsheet metal enclosure MCB DBSPN 8 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified and as directed.
153S & F MCB SPN 240 volts suitable for fixing in MCB DB of capacity 40 / 60 amps complete all as specified and directed.
154S & F MCB SP 5 to 40 Amps 240 volts for fixing on MCB DB"scomplete all as specified and as directed.
155Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below normal ground level connected to GIearth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mmbore by means of bolts, nuts, check nuts and washers including excavation earth work provisioning of PCC chamber made of PCC 1:3:6 RCC cover funnel with wiremesh 20mm dia watering pipe Medium grade, GI protection pipe 20mm dia bore all as specified in Electrical Plate No.3 of SSR Part I, 2009. complete all as specified and as directed.
156Supply and fix XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm of 3 core complete all as specified and as directed.
157S & F in repair Environmental fridendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs complete all as specified and as directed. Make: Havells RUGBYGENXFTS10WLED 865SSYMBOPCor equivalent to Bajaj/Wipro.
158Supply and fix wall mounted LED Batten, extruded aluminium heat sink provided for efficient heat dissipation & intergated electronic driver 1x10W, 230 Volts,DIFFUSED TYPE connector block, internally pre wired etc., with necessary mounting arrangements including all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make: Havells Cat No- LUMILINEPLUSBS10W LED 865SPCSS, Philips Cat No. BN021LED 1056500PSUGRS1, Wipro Cat No - LL20-111-XXX-65NE3.
159Taking down ceiling fans 1200/1400mm sweep and exhaust fan 230/300 mm sweep, cleaning of dust properly, greasing & overhualing of bearings including refixing and connecting up complete all as specified and as directed. Note : Replacement of defective/worn out parts will be measured & paid for separately
160S & F in repair capacitor 2/2.5 mfdcomplete all as specified and as directed. Make: - Asian/Usha/Epcos of siemens
161S & F in repairball bearing of exsiting ceiling fans complete all as specified and as directed..
162S & F in repair twisted three core copper flexible cable of size 1.5 sqmm from connector to the ceiling rose complete all as specified and as directed.
163S & F in repair‘U’ clamps complete with nut, bolts & split pins Heavy duty, suitable for existing ceiling fan complete all as specified and as directed.
164S & F in repairM.S. rod for ceiling fans 3 ft long with ‘U’ clamp at one end other end with out nut bolts washers or screwed thread with check nuts & pin complete all as specified and as directed.
165S & F in repairNut of bolts washers for fan blades fixing of ceiling fan of any make/size/type as per site requirement (6 Nos for each set) complete, a suitable for existing ceiling fan on site complete all as specified and as directed.
166M & L for Rewinding of motor complete with super enameled copper wire of gauge/ weight of copper coil, quick varnishing oiling, greasing insulating materials including replacement of worn out parts like u/s cotter pin, nut, screw, check nuts and bolts as required including cleaning of body and testing of the size 1200/1400mm sweep ceiling fans and 230/300mm exhaust fans of any make/model complete all as specifed and directed.
167M & L for spray painting of ceiling/exhaust fans of any size with two coats of synthetic enamel paint complete all as specified and as directed.
168Dismantling/taking down old/unserviceable distribution panel and supply, fixing and testing of indoor 3 phase LT distribution panel board factory made out of 2mm thick CRCA sheet CPRI approved of size not less than 600x450x200mmduly powder coated wall mounted/semi grouted in wall with locking arrangement double door type, compartmentalised and provision for tapping incomming & outgoing electric connections with suitable size of copper nut bolts & lugs, glands, one MCCB will be pre fitted/mounted on proper din rails and with earth link at top/bottom detachable plates and suitable for accomdating and including the following items :- (a)Copper busbar strips for TPN of 200 amps rating (min length of 250mm) and connected with MCCB by spreader terminals. ( set of 4 strips). (b)Phase indicating lamp LED type - one set of 3. (c)MCCB 4 pole, 63 Amps rating 25/26 KA breaking capacity, 415 volts - 01 No. Make: Havells/C&S/Standard.
169Supply and fix wall mounted light fitting suitable for and including 1 x 10 watt LED bulb complete all asspecified and as directed. Make: Havells Cat No. City-3 or equivalent in Wipro/Philips as approved by GE
170Supply and fix recess mountingwith perforated sheet with electronic driver luminaire 36 watts LED slim panel with central opal diffuser series mounted in ceiling surfaces including all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make: Havells Cat No - STARTO2X2PLR36W LED840MOD incl driver LED DRIVER36V36WS, Wipro Cat No - CRCO23R036HP65G3 and Philips Cat No RC383B LED36S-6500 PSU OD WH PIR.
171Supply and fix sheet metal enclosure MCB DB SPN 2 Way with 200 Amps rated bus bar of 240 Volts, double door with magnetic locking system for fixing MCB’s / isolators including taking down existing old unserviceable MCB DB complete all as specified and as directed.
172Supply laying or fixing or passing through pipe, 1100volts grade heavy duty cable with PVC insulated aluminium stranded served with inner sheathing of PVC tapeand overall PVC insulated in service connection suspended by insulating hangers not more than 1 meter apart including 4mm suspension wireof size 16 sqmm twin core cable complete all as specified and directed.