JAIPUR SMART CITY LIMITED has published Facade Illumination Work At Remaining Part / Buildings Of Major Arterial Road Of The Walled City Where Facade Illumination Work Has Not Been Done Including 3 Year All In All Comprehensive Maintenance Facade Illumination Work At Remaining Part / Building. Submission Date for this Tender is 20-06-2022. Electrification Work Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supply, installation, testing & commissioning of 300mmlong rigid architectural LED linear lightwith housing material ofextradedaluminum with die-cast aluminum end caps, Electrostaticallyapplied polyester powder coating fiish, system wattage not exceeding 15w and system lumen output of not less than 550 lumens and SDCM <_4. Fixture shall be available with 15 degreeX 35 degree ( ± 10%) beam angle, 2700± 300 degree kelvin color temperature. Fixture shall operate in a temperature range of -40 degree to 50 degree C. TheFixture shall be with integral driver, Fixture shall have input voltage for 120-270 VAC, 50/60Hz. Lifetime should be at least 50,000 buring hours at L70@ 35 Deg with total IP66protection. Fixture shall ewuipped with mechanical impact of minium :L06 and complet with all the accessories. Soft copy of catalogues, Test certificates-Third Party LM798, LM80, BIS Rnumber, IES files, polar cureve, illuminace diagra, is mandatory.Make:- OSRAM, Philips, Bajaj, Surya |
2 | Supply, installation, testing & commissioning of 600mm long rigid architectural LED linear light with housing material ofextradedaluminum with die-cast aluminum end caps, Electrostaticallyapplied polyester powder coating fiish, system wattage not exceeding 30Wand system lumen output of not less than 1200 lumens and SDCM <_4. Fixture shall be available with 30 degree ( ± 10%) beam angle, 2700± 300 degree kelvin color temperature. Fixture shall operate in a temperature range of -40 degree to 50 degree C. TheFixture shall be with integral driver, Fixture shall have input voltage for 120-270 VAC, 50/60Hz. Lifetime should be at least 50,000 buring hours at L70@ 35 Deg with total IP66protection. Fixture shall ewuipped with mechanical impact of minium :L06 and complet with all the accessories. Soft copy of catalogues, Test certificates-Third Party LM798, LM80, BIS Rnumber, IES files, polar cureve, illuminace diagra, is mandatory.Make:- OSRAM, Philips, Bajaj, Surya |
3 | Supply, installation, testing & commissioning of 900mm long rigid architectural LED linear light with housing material ofextradedaluminum with die-cast aluminum end caps, Electrostaticallyapplied polyester powder coating fiish, system wattage not exceeding 25Wand system lumen output of not less than 1500 lumens and SDCM <_4. Fixture shall be available with 30 degree ( ± 10%) beam angle, 2700± 300 degree kelvin color temperature. Fixture shall operate in a temperature range of -40 degree to 50 degree C. TheFixture shall be 24V DC with non integral driver. Lifetime should be at least 50,000 buring hours at L70@ 35 Deg with total IP66protection. Fixture shall ewuipped with mechanical impact of minium :L06 and complet with all the accessories. Soft copy of catalogues, Test certificates-Third Party LM798, LM80, BIS Rnumber, IES files, polar cureve, illuminace diagra, is mandatory.Make:- OSRAM, Philips, Bajaj, Surya |
4 | Supply, installation, testing & commissioning of 1000mm long rigid architectural LED linear light with housing material ofextradedaluminum with die-cast aluminum end caps, Electrostaticallyapplied polyester powder coating fiish, system wattage not exceeding 25Wand system lumen output of not less than 950 lumens and SDCM <_4. Fixture shall be available with 20 degree X 30 degree ( ± 10%) beam angle, 2700± 300 degree kelvin color temperature. Fixture shall operate in a temperature range of -40 degree to 50 degree C. TheFixture shall be 24V DC with non integral driver. Lifetime should be at least 50,000 buring hours at L70@ 35 Deg with total IP66protection. Fixture shall ewuipped with mechanical impact of minium :L06 and complet with all the accessories. Soft copy of catalogues, Test certificates-Third Party LM798, LM80, BIS Rnumber, IES files, polar cureve, illuminace diagra, is mandatory.Make:- OSRAM, Philips, Bajaj, Surya |
5 | Supply, installation, testing & commissioning of architectural LED flood light with housing material ofextradedaluminum with die-cast aluminum end caps, Electrostaticallyapplied polyester powder coating fiish, system wattage not exceeding 150Wand system lumen output of not less than 8000 lumens and SDCM <_4. Fixture shall be available with 8 degree ( ± 10%) beam angle, 2700± 300 degree kelvin color temperature. Fixture shall operate in a temperature range of -40 degree to 50 degree C. TheFixture shall be with integral driver, Fixture shall have input voltage for 120-270 VAC, 50/60Hz. Lifetime should be at least 50,000 buring hours at L70@ 35 Deg with total IP66protection. Fixture shall ewuipped with mechanical impact of minium :L06 and complet with all the accessories. Soft copy of catalogues, Test certificates-Third Party LM798, LM80, BIS Rnumber, IES files, polar cureve, illuminace diagra, is mandatory.Make:- OSRAM, Philips, Bajaj, Surya |
6 | Supply, installation, testing & commissioning of led round ceiling surface mounted LED down lighterwith following specifications: luminaire output 2000 lumens, diffused cover,2700 ± 300 degree kelvin color temperature, deep recessed, luminaire color graphite grey,IP54, complete with integrated power supply & installation clamp, cable entry & exist terminal for through wirings of mains, connectors/junction box etc.Make:- OSRAM, Philips, Bajaj, Surya |
7 | Supply, installation, testing & commissioning of architectural LED flood light with housing material of housing material of Die-cast Aluminum, Electrostatically applied polyester powder coating filish, System wattage not exceeding 25W and system lumen output not less than 1000 lumens and SDCM<_4. Fixture shall be available with 15° (±10%) beam angle, 2700 ± 300 degree kelvin color temperature. Fixture shall operate in a temperature range of -40°C to 50°C. The fixture shall be with integral driver, Fixture shall have input voltage for 120-270 VAC, 50/60Hz. Lifetime should be at least 50,000 burning hours at L70 @ 35deg with total IP66 protection. Fixture shall equipped with mechanical impact of minimum 1K06 and complet with all the accessories. Soft Copy of Catalogues, Test Certificates - Third party LM79,LM80,BIS R Number, IES Files, Polar curve, illuminance diagram is mandatory. Make:- OSRAM, Philips, Bajaj, Surya |
8 | Supply, installation, testing & commissioning of 1000mm rigid architectural LED Linear light with housing material of Extruded aluminum with die-cast aluminum end caps, Electrostatically applied polyester powder coating filth, system wattage not exceeding 25W and system lumen output of not less than 1500 lumens and SDCM 54. Fixture shall be available with 16" (±10%) Beam angle, Pink color. Fixture shall operate in a temperature range of -40°C to 50°C. The fixture shall be 24V DC with non-integral Driver. Lifetime should be at least 50,000 burning hours at L70 @ 35deg with total IP66 protection. Fixture shall equipped with mechanical impact of minimum 11(06 and complete with all the accessories and non- integral driver. Soft Copy of Catalogues, Test Certificates - Third party LM79,LM80,BIS R Number, IES Files, Polar curve, illuminance diagram is mandatory. Make:- OSRAM, Philips, Baja), Surya |
9 | Supply, installation, testing & commissioning of architectural LED flood light with housing material of housing material of Die-cast aluminum _ Electrostatically applied-polyester powder coating fiish, wattage not exceeding 150W and system lumen output of not less than 8000 lumens and SDCM <_4. Fixture shall be available with 15° (±10%) beam angle, Pink color. Fixture shall operate in a Temperature range of -40°C to 50°C. The fixture shall be with intergral driver, Fixture shall have input voltage for 120-270 VAC, 50/60Hz. Lifetime should be at least 50,000 burning hours at L70 @ 35deg with total IP66 protection. Fixture shall equipped with mechanical impact of minimum IK06 and complete with all the accessories. Soft Copy of Catalogues, Test Certificates - Third party LM79,LM80, BIS R Number, IES Files, Polar curve, illuminance diagram is mandatory. Make:- OSRAM, Philips, Baja), Surya |
10 | Supply, installation, testing & commissioning installation, testing & commissioning of flexible linear side emitting led modules with following specifications: luminaire output 600 lumens, assymetric Optics, 2700 ± 300 degree kelvin color temperature, IP66, complete with non integrated power supply & installation profile, clamp etc. Make:- OSRAM, Philips, Bajaj, Surya |
11 | Supply, installation, testing & commissioning of customised decorative bollard lights as per the drawing (drawing no- luc/o.c/b1d01 |
12 | Façade illumination work of major Arterial Road of walled city, Jaipur (Chora Rasta, tripoliya Bazar, johri bazaer, Kishanpole Bazar, choti Chopar, Chandpole Gate, sanganeri gate, Ajmeri gate, New gate, Tripoloya gate, hawamahal, Isarlat etc. The estimated amount (existing work order) of currently eloectricaleqipments present and are in operation such as rigid type linear LED"s of different colours and lumen outputs,Bllard stone light, ceiling round LED down lighter, Decorative pole post top lamp, copper and aluminium cable of different types and capacity, connectors, chokes, Pannel Boxes including all accessories like timers, contractors, MCB etc. is Rs.171452252/- |
13 | ALL IN ALL COMPREHENSIVE OPERATION & MAINTENANCE OF VARIOUS ABOVEELECTRICAL EQUIPMENTS |
14 | For Ist year ( 2.5% of total Part A + B Amount i.e. 171452252) |
15 | For IInd Year ( 5% of total Part A + B Amount i.e. 171452252) |
16 | For IIIrd Year (7.5% of total Part A + B Amount i.e. 171452252) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail