| 1 | Cleaning of septic tank chamber by removing effluent water and sludge and buried the same in excavated pits, by digging pits in hard/dense soil including removing surplus earth to a distance not exceeding 50 mtr from starting point and filling up the top portion of pit by excavated soil and sprinkling bleaching powder @ 0.5 Kg per Sqm on excavated areas including temporary baricades complete all as specified and directed. |
| 2 | Cleaning of 150mm dia SWG sewage pipe line including manholes after removing the cover (Cast Iron or RCC covers) and placing the same after cleaning the manholes/sewage line complete all as specified and directed. |
| 3 | Cleaning of 100mm dia SWG sewage pipe line including manholes after removing the cover (Cast Iron or RCC covers) and placing the same after cleaning the manholes/sewage line complete all as specified and directed. |
| 4 | Material and labour for attending/ clearing daily complaints of blockages of floor traps, gully traps, bathroom, WC, Kitchen and wash basin blockage opening etc The contractor will ensure the cleaning/clearing of all the complaints complete on same date. Cleaning of line will be carried as on required basis as directed by Engr-in-charge without affecting the progress of complaints by deploying addl safaiwala if needed and nothing extra will be paid on this account complete all as specified and directed. |
| 5 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation/sewage line and getting out in hard/dense soil complete all as specified and directed. |
| 6 | All as per serial item No 5 above but exceeding 1.5meter but not exceeding 3.00 mtr in depth complete all as specified and directed. |
| 7 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick, in hard/dense soil complete all as specified and directed. |
| 8 | Removal of surplus soil of distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed. |
| 9 | Demolition and breaking up drain pipes 150mm SWG pipe, set in cement morter complete all as specified and directed. |
| 10 | Demolition and breaking up drain pipes 100mm SWG pipe, set in cement morter complete all as specified and directed. |
| 11 | Material and labour for providing PCC (1:3:6) type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of bore 150mm on after they are laid and tested complete all as specified and directed.. |
| 12 | Material and labour for providing PCC (1:3:6) type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of bore 100mm on after they are laid and tested complete all as specified and directed. |
| 13 | Material and labour for Salt glased stone ware drain pipe 150 mm dia grade A laid in trenches and jointed in cement mortar 1:1 complete all as specified and directed. |
| 14 | Material and labour for Salt glased stone ware drain pipe 100 mm dia grade A laid in trenches and jointed in cement mortar 1:1 complete all as specified and directed. |
| 15 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round and 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 150mm internal dia of pipes complete all as specified and directed. |
| 16 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round and 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 100mm internal dia of pipes complete all as specified and directed. |
| 17 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 18 | Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for. |
| 19 | S & F mild steel TMT bar 10 mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed. |
| 20 | S&F Mild steelTMT bars 8 mm dia. and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips. |
| 21 | Material and labour for providing pre-cast RCC (1:2:4) type \"B-1\" using (20 mm graded crush stone aggregate) as in cover slabs of manholes and similar locationincluding necessary form work and set in cement mortar (1:4) complete all as specified and directed. |
| 22 | Demolition of precast cement concrete block walling built in CM complete all as specified and directed. |
| 23 | M&L for PCC 1:3:6 type C-1 (20 mm graded stone aggregate) precast cement concrete block masonary with solid blocks exc 10 cm in width and setting in CM 1:4 etc complete all as specified and directed. |
| 24 | M&L for rendering 15 mm thick in CM 1:4 on concrete surfaces using WPC @ 3% by weight of cement and finished the surface even and smooth without using extra cement complete all as specified and directed.(Note : WPC shall be measured and paid separately) |
| 25 | Supply only liquid Water Proofing Compound ISImarked. |
| 26 | S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cementcomplete all as specified and directed. |
| 27 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories) complete all as specified and directed. |
| 28 | S&F PVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints fixed to walls complete all as specified and diretced. |
| 29 | S&F PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed to walls complete all as specified and diretced. |
| 30 | S&F PVC (SWR) bends 110 mm bore of any radius provided with access doors complete all as specified and directed. |
| 31 | S&F PVC (SWR) junction single, (single T) equal or un equal with access doors 110mm dia complete all as specified and directed. |
| 32 | S&F PVC (SWR) bends 75 mm bore of any radius provided with access doors complete all as specified and directed. |
| 33 | Supply and fix vitreouschina squatting pan \" Orissa pattern \" size 680 x 470 mm white with \"P\" or \"S\" trap , front or back inlet with integral foot rests excluding flushing cistern and flush pipe and making good to floor complete all as specified and directed. |
| 34 | S&F in repairs PVC (SWR) couplers 110 mm bore with rubber ring joint fixed to walls complete all as specified and directed. |
| 35 | S&F PVC (SWR) WC connector 110 mm bore with lip ring complete all as specified and directed. |
| 36 | S&F vitreous china wash down water closet pan of padestal pattern, white, with P or S trap including connecting to trap and to flushing pipe etcand (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed. |
| 37 | S&F PVC flushing cistern low level 10 Ltr capacity of approved make including fixing of brackets connection to WC with CI brackets and making good disturbed area complete all as specified and directed. |
| 38 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 39 | M&L for screed bed or bedding layer of 15mm thick in CM 1:4 for laying tiles finishedrough. |
| 40 | M&L for Non-skid ceramic tiles 7 to 8 mm thick coloured tiles( square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed. |
| 41 | M&L for 25 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as insub base of flooring complete all as specified and directed. |