Military Engineer Services-MES has published Periodical Services To Building Under Zone A And Repair And Maintenance Of Summer/Cooling Appliances And Other Allied Works At Varanasi Cantt Under Ge (East) Allahabad.. Submission Date for this Tender is 18-06-2022. Air Conditioner Tenders in varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 07-Jun-2022 | Revised BOQ | BOQ | 18-06-2022 |
Sl. No. | Item Description |
1 | Checking of Air conditioner at site, transporting to workshop in E/M yard, dismantling of Air conditioner and taking down of compressor of air conditioner of window/Split type, 1.5/2.0 ton capacity, including cutting & brazing of suction/ discharge tubing complete all as specified & directed. |
2 | Supply and fixsealed compressor unit of capacity of 1.5 Ton window type air conditioner/ split type AC complete all as specified & directed. Make : ACCEL/ CARRIER/ Kirloskar Copland / VOLTAS/Copland as approved by GE. |
3 | Supply and fix sealed compressor unit of capacity of 2 Ton for existing window type air conditioner/split type complete all as specified & directed. Make : ACCEL/ CARRIER/ Kirloskar / VOLTAS/Copland as approved by GE. |
4 | Gas charging in Air conditioner window/Split AC 1.5/2 Ton Capacity with appropriate quantity of refrigerant Gas after fixing new compressor including replacement of filter strainer and testingcomplete all as specified & directed. |
5 | Detecting the cause of leakage and rectifying the same and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity suitable for window type AC/ split type AC including testing for smooth functioning complete all as specified & directed. |
6 | Repair/ Servicing to window type/split type AC 1.5 ton/2 ton capacity any make by dismantling the blower motor, condenser fan motor, fan blade, blower drum any type etc cleaning and servicing of serviceable parts, replacement of wiring kit, knob and unserviceable spare parts etc , replacement of insulation foam 3 mm thick, air filter and re- assembling the serviceable spare parts etc and testing for smooth functioning and re-installation at site or deposit in MES store yard complete all as directed by Engineer-in-Charge. Note :- Spare parts required shall be measured and paid seperatly as "Supply and fix" under respective item. |
7 | Supply and fix following spare parts of window type AC/split typeAC :- |
8 | Supply and fix Running capacitor 36/45/50 + 6mfd± 5%, 440 Volt AC. Make : Usha/ Asian/ Crompton greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE. |
9 | Supply and fix Relay for window AC. Capacity 1.5 T/2 T |
10 | Supply and fix Thermostate for AC |
11 | Supply and fix Blower motor, single phase, 230VoltAC for window air condtioner. Make : KIRLOSKAR/ JYOTI/ BEACONas approved by GE. |
12 | Supply and fix Blower fan blade made of plastic for air conditioner. |
13 | Supply and fix Condensor fan blade made of plastic for window or split air conditioner. |
14 | Supply and fix indoor unit complete for 1.5 ton split air conditioner. |
15 | Supply and fix condensor motor 1/10 HP single phase 230 V AC electric supply for outdoor unit of split |
16 | Supply and fix condensor motor 1/20 HP single phase 230 V AC electric supply for outdoor unit of split |
17 | Supply and fix outdoor unit complete including enegy efficient rotary compressor compete copper white for 1.5 Ton split AC. |
18 | Supply and fix PLC unit for split type air conditioner as same make and capacity. Make : CARRIER/ VOLTAS/ ACCEL /LG/Samsung/Blue Star asapproved by GE. |
19 | Supply and fix Split AC contactor single phase 230V of suitable capacity for Split AC 1.5 Ton/2 Ton including coil. Make : CARRIER/ VOLTAS/ ACCELas approved by GE. |
20 | S&F sub main wiring with two single core PVC insulated & unsheathed cable 6.0 Sqmm (nominal area) FR typemulti stranded copper conductor drawn in and including not less than 20mm dia rigid PVC conduit "medium grade" ISI marked including all conduit accessories for concealedwiring with and including cutting chases and making good of disturbed surfaces & applying finishes& including 6 sqmm FR typePVC insulated unsheathedcable multistrandedcopper conductor as earth wire connected to common earth as per IS including taking down existing complete wiring complete all as specified & directed. NOTE :Two runs of 6.0 Sqmm and one run of 6 Sq mm cable and PVC conduit shall be measured as a one unit length. |
21 | S&F in repair Sheet metal enclosure with three pin earth plug and socket complete with MCB 20 Amp Single Pole 240 Volt "C" curve and ultimate breaking capacity 10 KA including taking down existing unserviceable MCB DB complete all as specified & directed. |
22 | Checking of water cooler any capacity at site, transporting to workshop in E/Myard, dismantling of water cooler and taking down of compressor any capacity and type cutting & brazing of suction/discharge tubing complete all as specified and derected. |
23 | Supply and fix new sealed compressor unit of water cooler 60/120 Litre cooling capacity and make for suitable existing water cooler. MAKE: Copeland, Usha , Tecum sheh, Voltas, Blue Star, Accel, Hitachi, LG. |
24 | Supply and fix new sealed compressor unit of water cooler 40/80 Litre cooling capacity and make for suitable existing water cooler. MAKE: Copeland, Usha , Tecum sheh, Voltas, Blue Star, Accel, Hitachi, LG. |
25 | Gas charging in water cooler with appropriate quantity of refrigerant gas after fixing new compressor including replacement of filter strainer and testingcomplete all as specified & directed. |
26 | Labour only for Detecting & rectification of leakage and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity of refrigerant suitable for water cooler including replacement of fitter strainer testing for smooth functioning complete all as specified & directed. |
27 | Labour for Disconnecting of electric connection and water connection of water cooler, opening the condensor fan motor blade, electrical accessories and spare parts of system, carefully servicing of serviceable parts, replacement of un-serviceable parts oiling of fan motor etc, reassembling all spare parts including rewiring of internal connection of water cooler, re-connecting elec& water cooler connection ,testing and commissioning complete. Notes:- (i) Warn out or unserviceable spare parts to be replaced shall be measured and paid separately as Supply and fix under respective item. (ii) Replacement of nut & bolts washers deemed to be included in unit rate. (iii) Minor repair of chassis by brazing/ welding work deemed to be included in unit rate. |
28 | Supply and fix following spare parts for water coolers:- |
29 | Supply and fix running capacitor 25/36 mfd ±5% 440 Volt AC supply. Make : Usha/ Asian/ Crompton Greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE. |
30 | Supply and fixrunning capacitor 20/10 mfd± 5% 440 Volt AC supply. Make : Usha/ Asian/ Crompton Greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE. |
31 | Supply and fix starting capacitor 60/70 mfd. Make : Usha/ Asian/ Crompton Greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE. |
32 | Supply and fix starting capacitor 40/50 mfd. Make : Usha/ Asian/ Crompton Greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE. |
33 | Supply and fix starting capacitor 80mfd. Make : Usha/ Asian/ Crompton Greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE. |
34 | Supply and fix start Relay for water cooler any capacity. |
35 | Supply and fix over load protectorsame make and capacity. |
36 | Supply and fixthermostate |
37 | Supply and fix condensormotor 1/35 HP single phase 230V. |
38 | Supply and fix condensor motor 1/24 HP single phase 230V. |
39 | Supply and fixCondensing coil |
40 | Supply and fixplastic drain hose pipe (not exe 1.5 Rm) |
41 | Supply and fixPush cock/lift cock brass with chromium plated. |
42 | Supply and fix capillary Tube (not exceeding 0.60m). |
43 | Supply and fixFloat Valve 1/2 " including assembly brass made |
44 | Detection and rectification of leakage of storage tank of water cooler by brazing, soldering/ welding as required at site or at work shop and unserveciable spare parts such as Nipple adaptor, Push cock, float valve & Bush, nut, bolt, washer, rubber/plasting packing are included in unit quoted rates not any claim on this account will be replaced for smooth functioning & testing for leak proof complete all as specified and directed. |
45 | M&L for spray painting of water cooler after preparation of old surface of water cooler with one coat of synthetic enamel paint as approved complete all as specified and directed. |
46 | M&L replacement of drain tray with PVC pipe of water cooler, electroplating (chromium plating) of drain tray after repair by denting includingrefixing back complete all as specified and directed. |
47 | Repair maint of refrigerator, cleaning of indoor panel, servicing of serviceable parts, replacement of worn out parts, testing for smooth functioning of refrigerator, re-assembling all spare parts including rewiring of internal connection of Fridge, testing and commissioning complete all as specified and directed Notes:- (a) Worn out or unserviceable spare parts to be replaced shall be measured and paid separately as Supply and fix under respective item of BoQ. (b)nut/bolt & washers etcdeemed to be included in unit quoted rate. (c) Minor repair of chassis of brazing/welding work deemed to be included in unit rate. |
48 | Replacement of unserviceable compressor fromrefrigerator any capacity by cutting and brazing suction/ discharge tubing including charging of required qty of refrigerant gas complete including testing and commissioning for smooth functioning and satisfaction of Engineer-in-Charge. Note: (i) Compressor & spare parts shall be measured and paidseparately under respective item of BoQ Supply and fix item. (ii) Replacement of nut & bolts washers deemed to be included in unit quoted rate. (iii) Minor repair of chassis of brazing/welding work deemed to be included in unit quoted rate. |
49 | Detecting& rectifyingof leakage and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity suitable for refrigerator including testing for smooth functioning and satisfaction of Engineer-in-Charge. |
50 | Supply and fix sealed compressor unit of refrigerator 160 to 240Litre cooling capacity complete all as specified and directed. |
51 | Supply and fix sealed compressor unit of refrigerator 280 to 340Litre cooling capacity complete all as specified and directed. |
52 | Supply and fix following spare parts for refrigerators suitable for existing size and make at site:- |
53 | Supply and fix Relay |
54 | Supply and fixOver load protector |
55 | Supply and fix Thermostate |
56 | Supply and fix Cooling coil |
57 | Supply and fix Condensing coil |
58 | Supply and fix Bulb Holder |
59 | Supply and fixBulb pin type /screw type 15 Watt |
60 | Supply and fix Door switch |
61 | Supply and fixChilled tray |
62 | Supply and fix Vegitable tray |
63 | Supply and fixBottle supporter |
64 | Supply and fix Capillary Tubeing (note exceeding 0.36m) |
65 | Opening of the automatic voltage stabilizer Capacity 5 KVA/4 KVA for repair detection of fault and its repair cleaning of serviceable parts, replacement of unserviceable or worn out parts, soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally complete all as specified anddirected by Engineer-in-Charge |
66 | Opening of the automatic voltage stabilizer Capacity 2KVA/ 3 KVA for repair detection of fault and its repair cleaning of serviceable parts, replacement of unserviceable or worn out parts, soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally complete all as specified and directed by Engineer-in-Charge |
67 | Opening of the automatic voltage stabilizer Capacity single phase 230V1 KVA for repair detection of fault and its repair cleaning of serviceable parts, replacement of unserviceable or worn out parts, soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally complete all as specified by directed by Engineer-in-Charge. Notes for item No. 26 to 28 of BoQ :- (a) Worn/ unserviceable spare parts to be replaced with new spare parts shall be measure and paid seperately under respective item of BoQ (b)Providing flexible 3 core sheathed cable of size 40/.0076, 23/.0076, 70/.0076 to be provided at least 1.5 RM which will be deemed included in the unit quoted rate. |
68 | Supply and fix following spare parts suitable for voltage stabilizer of any make and anycapacity :- |
69 | Supply and fix Volt meter (0-300 volts). |
70 | Supply and fix Control relay. |
71 | Supply and fix IC controlled circuit for 5 KVA/4 KVA. |
72 | Supply and fix IC controlled circuit for3 KVA. |
73 | Supply and fixcontrol transformer rating input 170 to 250 Volt and output 230 Volt. |
74 | Supply and fixlow/high voltage cut off and TDR system. |
75 | Supply and fix main transformer for 5 KVA/4 KVA. |
76 | Supply and fix main transformer 3 KVA |
77 | Supply and fixmain transformer 1 KVA |
78 | Opening of the Desert Cooler of any capacity and make, dismantling of complete items and its repair cleaning of serviceable parts, replacement of unserviceable or worn out parts, opening of Fan motorfrom their brackets, scraping out of old paint of complete body (internally & externally) of Desert Coolers making good, smooth surface andapplying spray painting with one coat of synthetic enamel paintforexternal surfaces/ internal surface, replacement of wooden wool pad - 3 Nos and fixing of Fan Motor and Pump, replacement of internal wiring and rotary switch with pump and Fan motor connection and testing after repair complete. Note: (i) Overhauling/Oiling of fan motor, Vertical pump replacement of Nuts, bolts washers/elbow, if required shall be deemed to be included in unit quoted rate. (ii) Cost of replacement of grass pad deemed to be included in quoted rate. (iii) Unserviceable spare parts to be replaced shall be measured and paid separately as Supply and fix under respective item. (iv) Minor repair of chassis of brazing/welding work deemed to be included in unit rate. (v) Provide PVC Sheathedcable of 23/.0076 up to 1.5 meter in replacement if required will be deemed included in the unit rate. |
79 | Supply and fix following spare parts suitable for Desert Coolers existing make or existing capacity:- |
80 | Supply and fix fan motor of 1/6 HP to 1/10 HP230V AC electric of same capacity and same make |
81 | Supply and fix Blade for kit Fan. |
82 | Supply and fixMS Bracket for kit Fan Motor |
83 | Supply and fix Submersible Pump set suitable for desert coolers of fractional H.P. Make : CG/Bajaj/Havells/Vansal or Summar cool/ Zolta (Khaitan). |
84 | Supply and fix Rotory Switch |
85 | Supply and fix Piano type Switch, 5 Amp 230 Volt AC |
86 | Supply and fix Front Directional Grill |
87 | Supply and fix PVC pipe 10 mm dia flexible |
88 | Supply and fix Side panel made out of PGI Sheet 1 mm thick of size not less than 0.5 m width and 0.7m height complete. |
89 | Supply and fix Storage tank made out of PGI Sheet 1 mm thick of size not less than 0.7 m X 0.7M and height 0.2m complete. |
90 | Rewinding of fan motor Kit fan 450 mm sweep with super enameled copper wire (gauge/weight of copper coils shall be same as per existing dismantled fans), including varnishingcomplete all as specified and directed by Engineer-in-Charge. Notes :- (a)removing the defective fan & rectifying after repair including removing defective parts, burnt winding carefully, cleaning & re-assembling the fan after repair/servicing including oiling, greasing, washer, lock bolts, connector etc. depositing the fans to AGE E&M. office/ yard and testing complete to the entire satisfaction of Engineer-in-charge. |
91 | Supply and fix metal bush bearing for ceiling fan/ exhaust fan/ cabinet/ pedestal fan of any make/ sweep complete |
92 | Supply and fix capacitor 3.15/ 4 mfd + 5% 440VAC. Make: Usha/ Asian/ Crompton Greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE |
93 | Supply and fix PVC sheathed white colour three core copper flexible cable of size 23/.0076 complete. |
94 | Rewinding of fan complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), including quick varnishing for Ceiling Fan of 1200 mm sweep size of fans of any make complete all as specified and directed. |
95 | Rewinding of fan complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), including quick varnishing for ceiling Fan of 1400 mm sweep size of fans of any make complete all as specified and directed. |
96 | Rewinding of fan complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), including quick varnishing for exhaust Fan of 450 mm sweep size of fans of any make complete all as specified and directed. |
97 | Rewinding of fan complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), including quick varnishing for exhaust Fan of 380 mm sweep size of fans of any make complete all as specified and directed. |
98 | Rewinding of fan complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), including quick varnishing for exhaust Fan of 300 mm sweep size of fans of any make complete all as specified and directed. |
99 | Rewinding of fan complete with super enameled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), including quick varnishing for exhaust Fan of 225/230 mm sweep size of fans of any make complete all as specified and directed. NOTE for item No. 36 to 41 of BoQ : Collection of fan from AGE E&Moffice under contractor own arrangement for repair the same, removing defective parts, burnt winding carefully, cleaning & re-assembling the fan after repair including oiling, greasing, washer, lock bolts, connector etc.replacement of worn out/ unserveciaval parts, if required to be included in unit quoted rate depositing the fans to AGE E&M. office yard and testing complete to the satisfaction of Engineer-in-charge (Supply of spare parts will be measured and paid seperately under respective items of schedule). |
100 | Supply and fix Ball bearing size No. 6201 for ceiling/exhaust fan |
101 | Supply and fix Ball bearing size No. 6202 for ceiling/exhaust fan |
102 | Supply and fix Ball bearing size No. 6203 for ceiling/exhaust fan |
103 | Supply and fix capacitor 2.5 mfd rating complete all as specified and directed. Make: Usha/ Asian/ Crompton Greaves/ Sriram/ Havells/ Epicos/ Totaline as approved by GE. |
104 | Supply and fixrotor shaft for Ceiling/exhaust fan of any make/sweep complete all as specified and directed. |
105 | S&F in repair twisted two core copper flexible cable of size 23/.0076 from connector to the ceiling rose complete all as directed |
106 | Taking down from site, transporting to workshop and Over hauling only ceiling fan of any sweep/make i.e. opening of fan and cleaning ball bearing, filling grease/oil and changing of nut, screw, check nuts and bolts as required incl. cleaning of body, blades, down rods, canopies etc and re-assembling including refixing at site complete all as specified and directed. Notes:- (i) Worn out or unserviceable spare parts to be replaced shall be measured and paid separately as Supply and fix under respective item of BoQ. (ii) Replacement of nut, bolts & washers deemed to be included in unit quoted rate quoted by contractor. (iii) Minor repair of chassis by brazing/ welding work deemed to be included in unit quoted rate. |
107 | M & Lfor spray paintingof fan of any size with two coat of synthetic enamel paint (white) after cleaning of body, blades, down rods from dust, dirt, oil, grease etc. including re-writing MES fan Nos. on the body of fan, using black paint complete all as specified and directed. |
108 | Supply only canopy for ceiling fan suitable for any sweep / make as required complete all as specified and directed. |
109 | Supply and fix rubber reel for ceiling fans complete all as specified and directed. |
110 | Supply and fix CLAMP for down rod complete with rubber reel and nut bolts for ceiling fans complete all as specified and directed. |
111 | Supply and fix fan blade aluminium painted with white colour and suitable for 1200/1400 mm sweep ceiling fan complete all as specified and directed. |
112 | S&F in repair fan hook made out of 40x6 mm flat iron suitable for hanging of ceiling with proper size nut bolt and washers to be fixed in pipe of 40 mm bore dia complete all as specified and directed. |
113 | Supply only best quality bearing grease (01 Kg Packing) of Make - SKF or equivalent |
114 | M&L for taking out old rusted/unserviceable louver shutter of exhaust fan and supply and fix rust proof heavy duty aluminium frame lover shutter suitable for 250/300mm sweep exhaust fan all as specified and directed. |
115 | M&L for taking out old rusted/unserviceable louver shutter of exhaust fan and supply and fix rust proof heavy duty aluminium frame lover shutter suitable for 380/400/450mm sweep exhaust fan all as specified and directed. |
116 | S&F in repair GI tubing 40mm bore medium grade in required length and grouting in wall for hanging of ceiling fan all as directed by Engr- in -Charge ande making good disturbed surface of wall to match existing surface complete al as specified and directed. |
117 | S&F mild steel Anchor bolt/fasterner pin type 8mm dia 100mm long for fixing of exhaust fan/geysers etc all as specified and directed. |
118 | Repair maintenace and serving to UV/ Kent RO water purifier by replacing filter elements, connector pipes, solonoid valve, delevary valve & testing complete all as specified & directed. Note:Spare parts shall be measured and paid separately. |
119 | Supply and fix Kent RO pre carbon filter filter all as specified and directed. |
120 | Supply and fix Kent UF membrane 8" all as specified and directed |
121 | Supply and fix Kent RO inline carbon filter 8" all as specified and directed |
122 | Supply and fix Kent diaphragm pump 150 DPcomplete all as specified and directed |
123 | Supply and fix Kent UV assembly with UV lamp all as specified and directed |
124 | S&F Kent SMPS 2.5A 24 DC with wres complete all as specified and directed |
125 | Preparing old decorated plastered surfaces of walls including cornices, pilaster etc, by brooming down with steel wire brush, scraping down smoke soot, moulds, moss and efflorescent salt, greasy spots and applying one coat of white wash on wall surface complete all as specified & directed. |
126 | Complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, filling depressions of scrapped surfaces with wall care putty including preparation of surfaces by rubbing with appropriate size of sand or emery paper and applying two coats of white wash on walls surface complete all as specified & directed. |
127 | Preparing old decorated plastered surfaces of ceilings including cornices, pilaster etc, by brooming down with steel wire brush, scraping down smoke soot, moulds, moss and efflorescent salt / grasy spots and applying one coat of white wash on ceiliings surface complete all as specified & directed. |
128 | Preparing of old decorated plastered surfaces of walls including cornices, pilastered etc, by brooming down with steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and applying one coat of cement base paint on wall surface complete all as specified & directed. |
129 | Complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, filling depressions of scrapped surfaces with wall care putty including preparation of walls surfaces by rubbing with appropriate size of sand or emery paper and applying two coats cement base paint over complete all as specified & directed. Note : Time difference between one coat & second coat will be decided / ordered by Engineer-in-Charge. |
130 | Preparing of old decorated plastered surfaces of walls including cornices, pilaster etc, by brooming down with steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salt andtrading oil and greasy spots and applying one coat of acrylic emulsion paint colour or shade as approved complete all as specified & directed. |
131 | Complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrapper or any other means, filling depressions of scrapped surfaces with wall care putty and applying uniform layer of 1 mm thick wall care putty of Make :JK or Birla includingpreparation of putty surfaces by rubbing with appropriate size of sand or emery paper and applying two coats of acrylic emulsion paint of approved colour or shade as approved over and including one coat of primer complete all as specified and directed. |
132 | Preparing old decorated plastered surfaces of walls including cornices, pilastered etc, by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salt andtrading oil and greasy spots and applying one coat of exterior weather proof paint [ACE of Asian paints] of approved colour & hades including washing of floor, cleaning of glass, joinery, electrical fittings, wires etc, of drops & splash complete all as specified & directed. |
133 | Re-writing of letters or figures (Block, Roman, Italic or Indian) with fluorescent paint height of letter exceeding 15cm but not exceeding 30cm & width of letter exceeding 25mm but not exceeding 40mm wide complete all as specified & directed. |
134 | Applying one coat of synthetic enamel paint on wooden surfaces of any description, over 10 cm width or girthincluding preparation of old wood or wooden based surfaces complete all as specified & directed. |
135 | Applying one coat of synthetic enamel paint on steel surfaces of any description, over 10 cm width or girth including preparation of old steel surfaces complete all as specified & directed. |
136 | Taking down cement plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water including removing of all rubbish off from the site complete all as specified & directed. |
137 | Rendering of 10 mm thick cement sand mortar in 1:6 on fair faces of brick work or concrete surfaces, surface finished fair & even complete all as specified & directed. |
138 | Rendering of 10 mm thick cement sand mortar in 1:4 on fair faces of brick work or concrete surfaces, surface finished fair & even complete all as specified & directed. |
139 | Rendering of 5 mm thick cement sand mortar in 1:3 on ceiling of concrete surfaces, surface finished fair & even complete all as specified & directed. |
140 | Preparation of newly plastered surfaces of walls and applying three coats of white wash on walls including washing of floor, cleaning of glass, joinery, electrical fittings, drops & splash complete all as specified & directed. |
141 | Preparation of newly plastered surfaces of wall and applying two coats of oil emulsion paint over a coat of primer with wall care putty including washing of floor, cleaning of glass, joinery, electrical fittings, drops & splash complete all as specified & directed. |
142 | Preparation of newly plastered surfaces of walls and applying three coats of white wash on ceiling including washing of floor, cleaning of glass, joinery, electrical fittings, drops & splash complete all as specified & directed. |
143 | Preparation of newly plastered surfaces of walls and applying two coats of cementbase paint on wallsincluding washing of floor, cleaning of glass, joinery, electrical fittings, drops & splash complete all as specified & directed. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy