| 1 | Provision :- Schedule A :- 05 MVA 33/11 KV S/s - 01 No.Schedule B:- 11 KV Line Crossing on H-Beam- 05 No.Schedule C:- 33 KV Line on PCC pole - 8 KMSchedule D:- 33 KV DP Structure - 8 No.Schedule E:- 11 KV line on PCC Pole - 4 KMSchedule F:- 11 KV DP Structure on PCC Pole Schedule G:- 33 KV Line Road Crossing -2No. |
| 2 | LT Distribution box with Isolator & HRC Fuse 100KVA DTR (300A & 6 J HooK) |
| 3 | LT Distribution box with Isolator & HRC Fuse 100KVA DTR (300A & 6 J HooK), {Handling & Installation of Dist. Box on DP, Complete wiring, Connecting LT Cable on bushing and LT Feeder (2 Nos.)} |
| 4 | XLPE 1 Core Unarmoured 70 Sqmm aluminium 1100 V |
| 5 | Concreting of Rail/ Hbeam Supports @ 0.65Cmt. Per Pole including Muffingof Pole |
| 6 | Labour for Concreting of Rail/ Hbeam Supports @ 0.65Cmt. Per Pole including Muffingof Pole |
| 7 | Concreting of Foundation of VCB (1:3:6) @ 3.5CMT per VCB Plinth |
| 8 | Labour charges for Concreting of Foundation of VCB (1:3:6) @ 3.5CMT per VCB Plinth |
| 9 | Concreting of structures & foundation (1:3:6) |
| 10 | Labour Charges for Concreting of structures & foundation (1:3:6) |
| 11 | PTR Fnd. Cncrt:1:1.5:3 Rio 5.634,1:5:8 Rio 7.545 Cmt &M.S. Flat/Rod 324.87 KG (As per Drawing) |
| 12 | RS Joist 175x85MM 19.6KG/Mtr. 9.3Mtr. Long |
| 13 | RS Joist 175x85MM 19.6KG/Mtr. 9.3Mtr. Long(a) Pole Pit Digging in Soft Rock for RS Joist 9.3 Mtr. Long [Size (2\"x4\"x5\") = 40 Sq. Feet](b) RS Joist Pole Errection |
| 14 | PVC Insulated 2 Core Unarmoured 2.5 Sqmm Aluminium Conductor 1100 Volts |
| 15 | PVC Insulated 4 Core Unarmoured 16 Sqmm Aluminium Conductor 1100 Volts |
| 16 | MS Nuts and Bolts |
| 17 | Red Oxide Paint |
| 18 | Aluminium Paint |
| 19 | Danger Board Enamelled 33KV |
| 20 | Labour charges for Fixing of Danger Board Enamelled 33KV |
| 21 | 11 KV 1500 KVAR AUTO SWITCH CAPACITOR BANK INCLUDING ASSOCIATED |
| 22 | Handling & installation of 11 KV 1500 KVAR AUTO SWITCH CAPACITOR BANK INCLUDING ASSOCIATED |
| 23 | Fixing of 11KV Bus Bar Per bays strining Upper and Lower bus bar with drop Jumpers |
| 24 | 11KV Feeder/Xmer VCB Complete on Foundation & Tightening/ Aligment of VCB (11KV VCB, Outdoor Porcelain clad type with Complete Structure and accessories) |
| 25 | 11KV VCB Plinth Digging (3x2x0.6)=3.6 Cu. Mtr. |
| 26 | Base filling by Kopra in case of Black Cotton Soil 1.92 Cmt |
| 27 | Concreting of Structures & Foundation (1:3:6). |
| 28 | Labour charges for Concreting of Structures & Foundation (1:3:6). |
| 29 | Pit Digging for Capacitor Earthing |
| 30 | G.I Pipe 40MM Dia C Grade type |
| 31 | Galvanized Iron (GI) Flat 50x6 MM |
| 32 | OUTDOOR HEAT SHRINKABLE JOINTING KIT & LUG FOR 11 KVXLPE CABLE 3 CORE 185 SQMM |
| 33 | OUTDOOR HEAT SHRINKABLE JOINTING KIT & LUG FOR 11 KVXLPE CABLE 3 CORE 185 SQMM (Cable end terminal jointing including Kerosine/Gas, Tools and other Materials required for jointing by Heat Shrinkable kit for 11 KV with Testing and lead marking |
| 34 | Fire Extinguisher Cartridge CO2 10Kgs |
| 35 | 33/11 KV Power Transformer, OFTC Type 5000 KVALoss(4KW+23KW) |
| 36 | Crane Charges for Handling & Installation of PTR with Fitting of All Radiator (50 KM to 100KM) (5MVA PTR) |
| 37 | 33KV VCB, Outdoor Porcelain Clad type with complete structure and accessories |
| 38 | 33KV Feeder/Xmer VCB Complete on Foundation & Tightening/Aligment of VCB (33KV VCB, Outdoor Porcelain Clad type with complete structure and accessories) |
| 39 | 33KV Control & Relay Panel with Static Relay for Transformer Protection |
| 40 | Handling & Inst. Of 33KV Control & Relay Panel with Static Relay for Transformer Protection |
| 41 | 11KV VCB, Outdoor Porcelain clad type with Complete Structure and accessories |
| 42 | 11KV Feeder/Xmer VCB Complete on Foundation & Tightening/Aligment of VCB (11KV VCB, Outdoor Porcelain clad type with Complete Structure and accessories) |
| 43 | 11KV C.Ts. (Outdoor dry type) 300-150/5Amps. |
| 44 | 11KV C.Ts. (Outdoor dry type) 300-150/5Amps. (Handling & Installation of CT with Earthing arrengment) |
| 45 | 11KV Control & Relay Panel with Numerical Static Relay for 2Feeder Protection |
| 46 | Handling & Inst. Of 11KV Control & Relay Panel with Numerical Static Relay for 2Feeder Protection |
| 47 | 30 V 200 Amp Hour Battery Set in Transparent SAN Container |
| 48 | 30 V 200 Amp Hour Battery Set in Transparent SAN Container (Installation of Batteries on Wooden Rack Plat Form and Connection Each Cell (Total 15 Cells )& Connecting load with Battery Charger after Clamping Connection with Distribution Board, DC Bus Bar & Connecting Battery Charger with AC Switch Board Supply |
| 49 | Marshelling box with 10No. Connectors |
| 50 | 33KV, Isolator 600 Amp, (Turn and Twist type) |
| 51 | Fixing of 33KV, Isolator 600 Amp, (Turn and Twist type) |
| 52 | 33KV Polymer Lightening arrestor Gapless type (1Set=3No.) |
| 53 | Labour Charges for Fixing of 33KV Polymer Lightening arrestor Gapless type (1Set=3No.) |
| 54 | 9 KV Gapless type (5 KA) Polymer Lightening Arrestor (1Set= 3No.) |
| 55 | Labour Charges for Fixing of 9 KV Gapless type (5 KA) Polymer Lightening Arrestor (1Set= 3No.) |
| 56 | 33KV/110V 3Ph. 4Wire CT/PT 400-200/5Amp Outdoor Oil Immersed type, Class 0.2S |
| 57 | Installation of 33KV/110V 3Ph. 4Wire CT/PT 400-200/5Amp Outdoor Oil Immersed type, Class 0.2S |
| 58 | MS Sheet Shine Board, bay indication board & RYB phase indication board |
| 59 | 33KV Single phase PTs |
| 60 | 33KV Single phase PTs. (Handling & Installation of 33KV With Earthing Arrangment) |
| 61 | 11KV Single phase PTs. |
| 62 | 11KV Single phase PTs. (Handling & Installation of 11KV With Earthing Arrangment) |
| 63 | 3PH 4W 3x63.5V Ib=5A Imax-10A, HT trivector Meter, 0.5S, DLMS cat-A, GSW (S/S Meter) |
| 64 | 3PH 4W 3x63.5V Ib=5A Imax-10A, HT trivector Meter, 0.5S, DLMS cat-A, GSW (S/S Meter) (Labour rate of Installation of HT Meter (11KV & 33KV Both) Excluding ME with Modem Complete, meter box with TTB, Cabling & Wiring) |
| 65 | Sheet Metal Meter Box Suitable for HT Static Travector Meters With TTB |
| 66 | Direct Current Distribution Board (DCDB) 24 Volts Indoor Floor/ Wall |
| 67 | ACDB 415 V, along with three Phase-Neutral Voltmeter, Three Phase Ammeter. |
| 68 | LED Lamp With 90 Watt (Complete) |
| 69 | Copper control cable 8 Core, 2.5Sq.mm (Unarmoured) |
| 70 | Copper control cable 4 Core, 2.5Sq.mm (Unarmoured) |
| 71 | Copper control cable 2 Core, 2.5Sq.mm (Unarmoured) |
| 72 | T Clamp for 33KV & 11KV Bus Substation, |
| 73 | T Clamp for 33KV & 11KV Bus Substation, (Labour Charges for fixing of T Clamp for 33KV & 11KV Bus Substation) |
| 74 | Bi Metallic Clamp for Power Transformer of Brass flat 50x50x10MM |
| 75 | H-Beam 152x152mm, 37.1KG/Mtr. 9Mtr. Long |
| 76 | H-Beam 152x152mm, 37.1KG/Mtr. 9Mtr. Long(a) Pole Pit Digging in Soft Rock H-Beam 9Mtr. Long Size (2\"X4\"x5\")=40 Sq.Feet(b) H-Beam Pole Errection |
| 77 | H-Beam 152x152mm, 37.1KG/Mtr. 7Mtr. Long |
| 78 | H-Beam 152x152mm, 37.1KG/Mtr. 7Mtr. Long(a) Pole Pit Digging in Soft Rock H-Beam 7Mtr. Long Size (2\"X4\"x4.5\")= 36 Sq.Feet(b) H-Beam Pole Errection |
| 79 | H-Beam Clamps 65x8MM Flat |
| 80 | MS Strain Plate 65x8MM 250MM Long |
| 81 | ACSR Panther Conductor 0.20Sq.inch For Jumper |
| 82 | Stone Block/Pre cast block for Base Pedding (450x450x75MM) |
| 83 | H-Beam 152x152 MM, 37.1 KG/Mtr. 11 Mtr Long |
| 84 | H-Beam 152x152 MM, 37.1 KG/Mtr. 11 Mtr Long(a). Pit Digging in Soft Rock for 11 Mtr. H-Beam [Size (2\"x4\"x6\") = 48 Sq. Feet](b). H-Beam Pole 11 Mtr long Erection |
| 85 | 33KV Composite Polymer Disc Insulator |
| 86 | 33KV Strain Hardware (T&C type) Fittings |
| 87 | Labour charges for Fixing of 33 KV Disc Insulator With Strain H/w |
| 88 | 33KV, 10KN Pin Composite Polymer Insulator |
| 89 | Labour Charges for Fixing of 33KV, 10KN Pin Composite Polymer Insulator |
| 90 | 11 KV Composite Polymer Disc Insulators with Strain H/w |
| 91 | 11KV Polymer Pin Insulator |
| 92 | Labour charge for Fixing of 11KV Polymer Pin Insulator |
| 93 | H-Beam Back clamps 65x8MM Flat (in numbers) |
| 94 | Stay set without stay wire 16 MM (Painted) |
| 95 | Stay set without stay wire 16 MM (Painted)(a) Stay pit Digging in Soft Rock (16 MM)Size (5\"x2.5\"x5\") = 62.50 Cu. Feet(b) Stay Errection (Complete with Binding of Stay wire at eye bolt, Stay Insulator and anchor rod) |
| 96 | Stay Wire 7/3.15MM (7/10 SWG) |
| 97 | Earthing Coil of 115 Turns of 50MM Dia and 2.5Mtr. Lead of 4.0mm G.I. Wire |
| 98 | DTR 11/0.4 KV BIS EE-Level-2 100 KVA |
| 99 | DTR 11/0.4 KV BIS EE-Level-2 100 KVA (Labour charges for Handling & Installation of Distribution Transformer (DTR) on DP, tightening with Turn buckles on both sides, poles clamping and boting of base jumpering on HT Side] |
| 100 | Stay Clamp A type 65x8mm MS Flat R.S. Joist |
| 101 | 11 KV Polymer Lightening arrestor Gapless type (1Set=3No.) with Earthing |
| 102 | Labour Charges for Fixing of 11 KV Polymer Lightening arrestor Gapless type (1Set=3No.) with Earthing |
| 103 | 11 Kv. D.O. fuse Unit (1Set=3No.) |
| 104 | Labour charges for Fixing of 11 Kv. D.O. fuse Unit (1Set=3No.) |
| 105 | AAAC Rabbit conductor 0.05 sq. inch. (55 sq.mm. Al.Eq.) |
| 106 | Danger Boards Enamelled 11 KV |
| 107 | Labour Charges for Fixing of Danger Boards Enamelled 11 KV |
| 108 | EARTHING SET (DTR EARTHING) AS PER CIRCULAR NO 1516 DATED 17.03.08 |
| 109 | Earthing of New 33/11KV S/s as per Schedule G-3 (for Black Cotton Soil) (as per Drawing) |
| 110 | 11 KV Isolator complete with insulators 600 Amp. w/o earth switch |
| 111 | Fixing of 11 KV Isolator complete with insulators 600 Amp. w/o earth switch |
| 112 | 11 KV Oil Immersed 3 Phase 4 wire CTPT Units 300-150/5 Amp (ME) |
| 113 | Installation of 11 KV Oil Immersed 3 Phase 4 wire CTPT Units 300-150/5 Amp (ME) |
| 114 | 33 KV CTs.(out door oil filled type) 300-150/5 Amps |
| 115 | Handling & Inst. Of 33KV CTs. 300-150/5Amp (Handling & Installation of CT with Earthing arrengment) |
| 116 | 33 KV Top clamp 75x75x6MM angle type |
| 117 | Labour charges for fixing of 33 KV Top clamp 75x75x6MM angle type |
| 118 | DC Channel 100x50x6 MM 4.8Mtrs Center to Center |
| 119 | Labour Charges for fixing of DC Channel 100x50x6 MM 4.8Mtrs Center to Center (DC Cross arm along with Plates of Supporting Clamps on Both the poles) |
| 120 | DC Cross arms 5\" Center to Center (100x50x6MM) Channel |
| 121 | Fixing of DC Cross-arms 5\" Channel (100x50x6MM) along with Plates, 6 Nos, H/ws, 6 Nos. Disc Insulators and Fixing of Supporting Clamps on both the poles |
| 122 | DC Cross arms 8\" Channel (100x50x6MM) |
| 123 | Fixing of DC Cross-arms 8\" Channel (100x50x6MM) along with Plates, 6 Nos, H/ws, 6 Nos. Disc Insulators and Fixing of Supporting Clamps on both the poles |
| 124 | Transformer Mounting Channel (100x50x6MM) |
| 125 | Transformer Clamping set 50x50x6MM Angle 460MM |
| 126 | Three Phase Static Energy Meters 20-80 Amps With L.S. & TOD Facility with Box |
| 127 | Three Phase Static Energy Meters 20-80 Amps With L.S. & TOD Facility with Box [Labour only for Installation of Three phase Meter on 12\" X16\" Poly Carbonate/Wooden Board (Excluding the cost of Board), But including Making holes in the Board, Fixing the board on the wall, Screing the meter on the Board, Screwing incoming & Outgoing Terminals including earth terminals] |
| 128 | Horizonatal and Cross Bracing 5\" Centre with Supporting Clamps on both the Poles |
| 129 | Labour Charges for Fixing of Horizonatal and Cross Bracing 5\" Centre with Supporting Clamps on both the Poles |
| 130 | 11KV Top clamp 75x40x6mm angle type (S/s) |
| 131 | Labour charges for fixing of 11KV Top clamp 75x40x6mm angle type (S/s) |
| 132 | H-Beam 152x152 MM, 37.1 KG/Mtr. 13 Mtr Long |
| 133 | H-Beam 152x152 MM, 37.1 KG/Mtr. 13 Mtr Long(a). Pit Digging in Soft Rock for 13 Mtr. H-Beam [Size (2\"x4\"x7\") = 56 Sq. Feet](b). H-Beam Pole transportation 00KM upto 01KM (c). H-Beam Pole 13 Mtr long Erection |
| 134 | Stay set without stay wire 20 MM (Painted) |
| 135 | Stay set without stay wire 20 MM (Painted)a).Stay Pit Digging (20 MM ) Size (5\"x2.5\"x5\")= 62.50 Cu. Feetb).Stay Set erection (Complete with Binding of Stay Wire at eye Bolt, Stay insulator and Anchor Rod) |
| 136 | Stay GI Wire 7/4.00 MM (7/8 SWG) |
| 137 | G.I. Wires 5.0 MM (6 SWG) |
| 138 | G.I. Wires 4.0 MM (8 SWG) |
| 139 | Concreting of stay @ 0.3 Cmt. per stay |
| 140 | Labour charges for Concreting of stay @ 0.3 Cmt. per stay |
| 141 | 11 KV V Cross arms 65x65x6MM with 11 KV top clamps |
| 142 | Fixing of 11 KV V Cross arms 65x65x6MM with 11 KV top clamps |
| 143 | Anti climbing device (Barbed Wire) GS 2.24 MM Dia (14 SWG) |
| 144 | Labour charges for fixing of Anti climbing device (Barbed Wire) GS 2.24 MM Dia (14 SWG) |
| 145 | Aluminium Binding Wire and Tape |
| 146 | I. Bolts 16 MM |
| 147 | Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor |
| 148 | AAAC/ACSR Raccoon conductor 0.075Sq. Inch (03No. Condt.) (11 KV) |
| 149 | Stringing of AAAC/ACSR Raccoon conductor 0.075Sq. Inch (03No. Condt.) (11 KV) |
| 150 | Survey of 11 KV line During Execution of Work |
| 151 | PCC Pole 9.1Mtr., 280KG Long |
| 152 | PCC Pole 9.1Mtr., 280KG Long(a) Pole Pit Digging in Soft Rock, 280 kg on PCC Pole size (2\"x4\"x5\")=40 Feet(b) Pole transportation 00KM upto 01KM (c) PCC Pole Errection with Earthing |
| 153 | Stay clamp 65x8 MM of MS flat for PCC pole 280KG |
| 154 | Stay Insulators 90x65MM |
| 155 | Back Filling of Poles with boulders |
| 156 | Back Clamp for 280 KG PCC Pole of MS Flat 50x8 mm |
| 157 | AAAC/ACSR Raccoon conductor 0.075Sq. Inch (03No. Condt.) (33 KV) |
| 158 | Stringing of AAAC/ACSR Raccoon conductor 0.075Sq. Inch (03No. Condt.) (33 KV) |
| 159 | Survey of 33 KV line During Execution of Work |
| 160 | 33 KV V-Cross arm with 33 KV Top Clamp |
| 161 | Labour charges for Fixing of 33 KV V-Cross arm with 33 KV Top Clamp |
| 162 | MS Strain Plate 65x8 MM 250 MM Long |
| 163 | 33 KV Composite Polymer Disc Insulators |
| 164 | 33 KV Strain hardware (T&C type) fittings |
| 165 | DCCross arms 5\" Along with Plates, 6 No. H/Ws, 6 Nos. Disc insulators and fixing of Supporting Clamps on both the Poles (100X50X6MM) Channel |
| 166 | Labour Charges for Fixing of DC Cross arms 5\" Along with Plates, 6 No. H/Ws, 6 Nos. Disc insulators and fixing of Supporting Clamps on both the Poles (100X50X6MM) Channel |
| 167 | 140 kg. 8.0 mtr. Long PCC pole |
| 168 | 140 kg. 8.0 mtr. Long PCC polea). Pole Pit Digging in Soft Rock for 140 KG PCC Pole [Size (2\"x4\"x4.5\") = 36 Sq. Feet]b). Pole transportation 00KM upto 01KM c). PCC Pole 8 Mtr long 140 KG Erection with Earthing |
| 169 | Clamp for 140 KG Pole Pole MS Flat 50x6 MM |
| 170 | Concreting of Stay @ 0.2 Cmt/ Stay |
| 171 | Labour charge for Concreting of Stay @ 0.2 Cmt/ Stay |
| 172 | 11 KV V Cross arms 75x40x6 MM with 11 KV top clamps |
| 173 | Fixing of 11 KV V Cross arms 75x40x6 MM with 11 KV top clamps |
| 174 | Back Clamp for 140 KG PCC Pole MS Flat 50x6 MM |
| 175 | Concreting of stay @ 0.2 Cmt. per stay |
| 176 | Labour charges for Concreting of stay @ 0.2 Cmt. per stay |
| 177 | Earthing for PCC Pole 4.00 MM- 8 SWG G.I. Wire - 0.8 KG, Per Pole |
| 178 | Horizonatal and Cross Bracing 8\" Centre with Supporting Clamps on both the Poles |
| 179 | Labour Charges for Fixing of Horizonatal and Cross Bracing 8\" Centre with Supporting Clamps on both the Poles |
| 180 | I. Bolts 20 MM |
| 181 | 33 KV Guarding of MS Channel 75x40x6 MM (Carpet Guarding) |
| 182 | Labour charges for Fixing of 33 KV Guarding of MS Channel 75x40x6 MM (Carpet Guarding) |
| 183 | GST @ 18% |