Water Corporation of Odisha-WATCO has published Supply, Installation, Testing And Commissioning Of Variable Frequency Drive With Master Plc And Ofc Cable For 8.00 Mld Wtp At Pratap Nagari Related To 24X7 Water Supply To Ward No.56, 57 And 59 Cmc, Cuttack . Submission Date for this Tender is 08-06-2022. Industrial Drive Tenders in cuttack Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Retrofitting,Testing & Commissioning of Communication Compatable Logic controller type IGBT Based AC to DCto Ac conversion type140A VFD ambient temparture 50 degree without derating humidity - 95% RH, complete with Rated Copper BusBar and interconnection with copper wire and lugs.in existing MCC by removing Star/Delta starter with all accessories.Having 200KA 200A Semiconductor high speed Fuse with holder-3Nos,4A DC DP MCB-2 NOS,6A DP MCB-2Nos,156A ASD -1Nos , AUxilary contactor 4No -3NOs, 2No+2NC Addon block- 3Nos,Copper wound 163A Output Chock-1 Nos Cooling Fan with filter -2nos,24VDC Powersupply module-2 Nos, 2.5mm Control Terminal -10 Nos,All switchgear and controlgear make- Siemens,schneider,ABB, VFD Make- Schneider ATV930, Rockwell- Powerflex 700 AC, Vecon. All completed asper electrical specification and as per direction of EIC. |
2 | Retrofitting,Testing & Commissioning of Communication Compatable Logic controller type IGBT Based AC to DCto Ac conversion type60A VFD ambient temparture 50 degree without derating humidity - 95% RH, complete with Rated Copper BusBar and interconnection with copper wire and lugs.in existing MCC by removing Star/Delta starterwith all accessories.Having 200KA 63A Semiconductor high speed Fuse with holder-3Nos,4A DC DP MCB-2 NOS,6A DP MCB-2Nos,52A ASD -1Nos , AUxilary contactor 4No -3NOs, 2No+2NC Addon block- 3Nos,Copper wound 60A Output Chock-1 Nos Cooling Fan with filter -2nos,24VDC Powersupply module-2 Nos, 2.5mm Control Terminal -10 Nos,All switchgear and controlgear make- Siemens,schneider,ABB, VFD Make- Schneider ATV930, Rockwell- Powerflex 700 AC, Vecon. All completed asper electrical specification and as per direction of EIC. |
3 | Supply, Installation, Testing Wiring & CommissioningofPLC panel Made out of 2MM C.R sheet, Duely Powder coated, Wall mounted/floor standing, Front operated, complete with interconnection with copper wire and lugs.(Make-Rittal,BCH,Hoffman)Having Type 2-1P+N 15kA Surge protection device- 1Nos ,32A 15KA MCB - 1 nos, DC powered Transistor/Relay based128DI and 64DO EthernetPLC Module, 35 Micosecond Response time for DI/DO Switch on/off, 12 Analog input module having 1ms per channel conversion/sampling time. 6 Analog Output module having 1ms per channel conversation/ stabilisation time. Ambient air tempature upto 55 "C. (Make- Siemense ,Schneider-,Allen Bradly).Rated DP Separate DC MCB for Indivisual Modules.12 ch Analog Interface card for Analog input-1Nos, 6Ch analog Interface Card for Analog Output-1Nos (Make - Masibus,Rishab,Shavision)24VDC 16 Ch 1C/O type Relay Board for Digital out put - 1 Nos (make-wago,phoenix contact). 5 Ch Unmanaged Industrial Grade Switch- 1 Nos. (Make- wago,schneider,siemense,Allen Bradley) . |
4 | 4U wall-mount Rack/Cabinet shelf or self-standing & is great for organizing your DVR-NVR-Server-Network devices. 4U rack has a key lock feature for keeping your device safe in this cabinet. This rack is made with the highest care while making it. Since making its quality, best, 6-way processed powder coating is done for long-lasting, Corrosion and Rustproof. Top and bottom cable entry provides optimal flexibility for cable management. It also has 4 Power sockets surge protector and 1 AC AXIAL cooling Fan attached in it. Rack size: 45 X 55 X 25.5 CM. Weight: 9.20 kg. Colour: Gray. Package Contains 1 Rack, Screws, Nylon Sleeves, 2 Keys. |
5 | Gigabit SFP to RJ45 Fiber multi Media Converter | Fiber to Ethernet Converter | 10/100/1000Mbps RJ45 Port to 1000Base-LX Dual-Mode Fiber(Make - Dlink or equivalent) |
6 | 24 port fiber optic panel or light interface unit to terminate and protect optic cables and fibers in communication networks |
7 | OFC Splicing with pigtails |
8 | Optical fiber 12-port managed L3 gigabit fiber switch and media coverter for non-blocking throughput switching, high performance and low latency, Gigabit Ethernet SFP and RJ45 ports (Make- Digisol- SG-GS4600FSE or equivalent |
9 | Fiber SFP Multi mode transicever 100 base LC type module |
10 | SM(OS2) Duplex Patch cord 3mtr LC-SC,PC type |
11 | Fiber Pigtail/patchcord 1 mtr |
12 | Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately. |
13 | Cutting asphalt or bituminous road of flexible pavments and disposal of dismantalled materials up a lead of 1000 mtr stacking servicable and unservicable materials separately including cost of alllabour, T & P etc. all complete as per the direction of engineer-in-charge. |
14 | NH crossing : Crossing of NH by Drilling/boaring with 75 mm GI pipe for cable laying whereever required, Job complete incluiding all labour, Hire of Mechinary, DG charges complete as per specification of E.I.C. |
15 | CABLE TRENCH: Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 0.9 metres or bellow to the water Pipeline including backfilling the trench, job complete in all respects, including all labour and materials complete as per specification and directions of Site Engineer /Engineer-in-Charge. |
16 | Filling sand in F&P in pipeline trenches with good river sand ramming with as per specification and directions of Site Engineer /Engineer-in-Charge. |
17 | Filling in pipeline trenches with excavated soil/availabe earth (excluding rock )with addequet compaction, labeling etc all completeas per specification and directions of Site Engineer /Engineer-in-Charge. |
18 | HDPE PIPE: Supply and Laying of 40MM dia HDPE pipe (Make: Supreme/equvalent) in cable trench as per specification and directions of Site Engineer / Engineer-in-Charge. |
19 | Supply and Installationof pre-fabricated GRP Joint Box with Iid size 600 x 600 x 600 mm for OFC loop and terminationas per telecom specification and directions of Site Engineer / Engineer-in Charge. |
20 | OFC: Supply and Laying of 12core armoured Optical fibre cable (OFC :fiber glass with F-G 62.5/125micron, 2.6DB/KM F600) to various sites through HDPE pipe /in AIR ( pole to pole ), prelaying testing of each cable drum for each fibre and taking the OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ Site Engineer. |
21 | Supply and Installation of OFC jointing kits as per drawings, specifications and directions of Engineer-in-charge/Site Engineer. |
22 | Mending with plain cement concrete (1:2:4) with 12 mm size crusher broken hard Granite chips including cost of all labour , materials with all taxes , lead , T & P etc all complete as per specification and directions of Site Engineer /Engineer-in-Charge. |
23 | 6000.00x0.30x0.25=450.00 |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy