Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #32408313

Provision Of Living Accn For Trainees At Cti Af Stn Jalahalli West Under Ge M Af Jalahalli Bangalore

Issued by Statutory Bodies & Commissions/Committees · jalahalli, Karnataka
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Jun 2022
0 days left
EMD
87600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jalahalli → Karnataka
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Provision Of Living Accn For Trainees At Cti Af Stn Jalahalli West Under Ge M Af Jalahalli Bangalore

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Jun-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-Jun-2022

BOQ

NAME OF WORK: PROVISION OF LIVING ACCN FOR TRAINEES AT CTI, AF STN JALAHALLI WEST UNDER GE (M) AF JALAHALLI BANGALORE.
Sl. No. Item Description
1Sch \"A\" Part I B&R works Excavation in trenches n exc 1.5 m wideandn exc 1.5 m depth in soft and loosesoil for foundation etcor for shaft, wells, manholes, pier holes etc n exc 10 Sqm on plan and not exc 1.5 m in depth and getting out complete all as specified and directed.
2Material and labour PCC1:4:8, type D-2 (using 40mm graded stone aggregate) as in mass concrete, foundation filling etc complete all as specified and directed.
3Material and labour RCC 1:2:4, type B1 (using 20 mm graded stone aggregate) nominal mixfor foundation, including rafts, footings, foundation beams, plinth beam, bases for columns etc basement slabs, under reamed piles and mass concrete complete all as specified and directed.
4Material and labour RCC 1:2:4, type B1 (using 20 mm graded stone aggregate) nominal mix for columns, pillars, piers, posts, and struts complete all as specified and directed.
5Material and labour RCC type B1 1:2:4, 20 mm graded stone aggregate (nominal mix) in beams, cantilevers, bressummers, lintels over 1.5 m span
6Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, lintel beam and similar work; vertical or to batter fair finished surfaces flat complete all as specified and directed.
7Use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions vertical or to batter fair finished surfaces flat complete all as specified and directed.
8Material and labour for pre cast cement concrete block masonry type C1, 1:3:6 (20 mm graded aggregate)solid blocks exc 10cm in width having minimum compressive strength of 50 kg/sq cm as per IS 2185 (Part I) 2005 and set in cement mortar 1:4 complete all as specified
9Material and labour for pre cast cement concrete block masonry type C1 1:3:6 (20 mm graded aggregate)solid blocks 10cm thick with plain or interlocking joints as directed having minimum compressive strength of 50 kg/sq cm as per IS 2185 (Part I) 2005 and set in cement mortar 1:4 complete all as specified
10Material and labour Rendering 15 mm thick cement plaster in CM 1:4 for fair faces of brickwork or concrete surfaces wall finished even & smoothwithout using extra cement.
11Supply only integral water proofing compound of approved make.
12Material and labour for rendering 15mm thick in CM 1:6 on concrete/brick surfaces (internal) finished even and smooth without using extra cement complete all as specified.
13Material and labour for preparation of plastered surfaces of walls and applying two coats of cement base paint over primer alkali resistance on new surfaces.
14Material and labour forPreparing New plastered surfaces of walls by brooming down or by steel wire brushing , scrapping down and applying three coat of white wash complete all as specified and as directed.
15Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil all as specified.
16Removing the excavated soil to a distance not exe 50m and depositing where directed at a level n exe 1.5m above the starting point all as directed.
17Supply and fixing TMT bars10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia completeall as specified and directed.
18Material and labour for TMT steel bars of 5mmand over up to and including 10mm, cut to length, bent to shape required, including cranking, bending spirally in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified anddirected.
19Supply and fixing mild steel bolts, dia of neck exc 20mm n. exc. 25mm purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long embedded in RCC complete all as specified and directed
20Supply and fixing mild steel bolts, dia of neck exc 11mm n. exc. 15mm machine made, with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm and n exc 10cm long complete all as specified and directed
21Material and labourStructural steel of plates, Fe-410 W (Gde E-250) Quality-B), channels, square cut or notched (ordinary or counter sunk) forming holes with riveted, bolted or welded attachments all as specified and directed
22Material and labour Plain Cement Concrete 1:2:4 type B1 using 20 mm stone aggregate for embedding M S PIPES or similar work all as specified and directed.
23Material and labour for Mild steel work as in angle Iron, Channel section, flat Iron for fixed indecently connecting purlin, rafters, MS plate as reqd forming holes bolted and welded attachment and curved shaped by welding (thickness of metal n.exc.6mm) making joint less by filling including cutting etc complete all as specified.
24Supply and fixing Rolled Mild steel in Roof trusses (framed), trussed, purlins, rails and fastenings and heavy brackets framing including distance pieces, cleats etc Fe 410-W (Gde E-250) quality B all as specified and directed
25Supply and fixing of Rolled section having Fe 410-W (Gde E-250) quality B as in main and cross beams, hip and jack rafters, hollow/solid section columns: purlins where connected to common rafters and running rails and guides for sliding doors: fixed with angle cleats or other connecting plates all as specified and directed.
26Material and labour for powder coatedAluminium snap grid (minimum 50 microns thickness powder coating) of size 605 x 605 mm with anodised aluminium angle of size 25mmx25mm x1.5mm thickandmain & cross T of size 40mm x 25mm x 1.5mm thick for false ceiling including fixing of supporting hangers all as specified and directed .Note :Cost of hangers will be measured & paidseparately under relevant items of this schedule
27Supply and fixing Hangers 6 mm dia GI (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified.
28Supply and fixing 12 mm thick Gypsum board of size 600 x 600 mmin ceiling fixed with screws and finished with two coats oil bound distemper over a coat of self primer all as per manufacturers instructionscomplete all as specified and directed.
29Supply and fixing pre painted glavalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified (Note :- The length of self tapping screw may vary for wooden and steel truss.Contractor to quote rate accordingly.)
30Material and labour pre painted glavalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in ridges, roof covering/cladding to wall, fixed with self tapping screws as specified (Note :- The length of self tapping screw may vary for wooden and steel truss.Contractor to quote rate accordingly.)
31Supply and fixing 60 mm thick 40 kg/m³ density PUF insulated panels sand witched between two sheets of 0.50 mm thick pre-painted galvansed iron sheet cladding on both sides having internal finish with ivory colour and external finish with camouflage pattern and toung and grove joints at both vertical side,panels have locking arrangements with check nuts for joining of panels of each other also heat transmission coefficient all as per IS 661-2000 and IS 3792. Panels will be provided with additional reinforcement in form of suitable MS hollow section vertically and horizontally at suitable intervals on over all as directed. Make:-Cactus Profile Pvt Ltd/ Unifix/Prestaror equivalent IS approved make. (Note:- Vertical steel reinforcement provided will be measured and paid separately)
32Material and labour Cement concrete type C2, 1:3:6 (40mm graded aggregate) 75 mm thick as in plinth protection including finishing of concrete surface even and smooth without using extra cement all as specified.
33Material and labour for hard core of broken stone aggregate gauge not exceeding 63 mm deposited spread and levelled in layers n exc 15 cm thick, watered and well rammed to a true surface
34Material and labour PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in flooring with 75mm thickness
35Material and labour 25mm thick PCC 1:2:4 type B0 (Using 12.5 mm graded stone agg) as in floor finished even and smooth without using extra cement.
36Material and labour for 15mm thick screed bed or bedding layer of cement mortar (1:6) as in floor for laying floor finishes complete all as specified.
37Material and labour for rendering 10mm thick in CM 1:3 on fair faces of brick work or concrete surfaces as in backing coat to receive wall tiles etc.
38Material and labour for Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,as in floor, set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles complete all as specified.
39Material and labour for coloured glazed ceramic tiles of size 300x200x7 to 8mm thick on vertical surfaces such as skirting, dados etc, set and jointed in neat cement slurry and pointed in colouredcement to match.
40Material and labour forRolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete drilled for fixing of steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting (exclusive of steel sheeting or other covering, running, also fasting and fixing complete. Fe 290 (Gde E-165)
41Material and labour for factory made Flush shutters 35 mm thick, solid core construction, with particle board core and plywood face panels, commercial type on both sides all as specified and as directed.
42Supply and fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube all as specified and directed.
43Supply and fixing factory made solid PVC moulded door shutter 28 to 30mm thick (stiles), with 2,4 or 6 raised panel design with 5mm thick moulded PVC prelam sheet on front face and 5mm prelam coloured PVC sheet on back face, complete all as specified and directed by Engr-in-Charge.
44Supply and fixing Steel Window/ ventilators with top hungshutter including hinges, steel peg stay etccomplete all as specified and directed.
45Supply and fix sheet plain glass, ordinary quality, in squaresn exc 0.5 sqm for each pane of 4 mm thickness all as specified and directed
46Supply and fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or steel screws all as specified
47Supply and fixing140 mm floor door stopper of aluminum alloy body and tongue, anodised with hard drawn steel spring fixed in floor.
48Supply and fixing 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed.
49Supply and fixing Butt hinges 100 mm long medium Weight cold rolled mild steel and fixed.
50Supply and fixing for 300 mm long Aluminium alloy ,anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast of extruded section and fixing bolts and sliding bolts extruded sections or cast aluminium alloy and fixed.
51Supply and fixing 150 mm long extruded aluminium alloy anodised handle fabricatedtype.
52Supply and fixing Harrison rails, mild steel, chromium plated with fixing brackets, stops roller etc. all as specified and as directed.
53Material and labour for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applyingtwo coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
54Material and labour Painting and preparation of new wooden surfaces applying pink primer and two coats of synthetic enamel paint (ordinary tint)over 10cm width or girth all as specified and directed.
55Supply and fixvitreous china squatting pan Orissa pattern size 580 x 440 mm white with \"P\" and \"S\" trap front or back inlet etc including provision of PCC (1:5:10) concrete complete all as specified and as directed
56Supply and fixing in repair PVCHigh or low level flushing cistern 10 liters capacity (exclusive of brackets), and connections to pipes and fixing of chain and pull, or lever, Joint between flushing pipe and socket of W.C. pan pre-made, if any complete all as specified and as directed.
57Supply and fixwash basins, vitreous China (flat back or angle back type)size 550x400 mm, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and as directed
58Supply and fix 15 mm borefancy type pillars taps chromium plated cast copper alloy with capstan head, long screwed shanks complete all as specified and as directed.
59Supply and fix waste coupling of PTMT (half or full threaded) Minimum weight 32mm- 45gms complete all as specified and as directed.
60Supply and fixlooking mirror of size of 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and aluminium frame fixed to wooden plug with chromium plated brass screw & cup washer complete all as specified and as directed.
61Supply and fixing in75 mm bore PVC (SWR) floor trapwith grating incl jointing with solvent cement
62Supply and fixing fancy typebrass chromium plated shower rose with arm complete
63Supply and fixingchromium plated towel rail 20mm dia D type 60 cm long.
64Supply and fixing in CP soap disk fixed with screw to wall complete
65Material and labour for 15mm bore steel tubes “medium grade” galvanised with all fitting and fixed complete in walls ceiling or laid in floors.
66Material and labour for 20mm bore steel tubes “medium grade” galvanised with all fitting and fixed complete in walls ceiling or laid in floors.
67Material and labour for Cutting chases pinning in making good to facing where required for concealed water tubingand making good cutting not exc 10cm girth in brick walls complete.
68Material and labour for Bib taps cast copper alloy fancy type chromium plated 15mm bore fixed complete
69Supply and fixing stop valves cast copper screwed down high pressure fancy type screwed both ends for pipe or union fixed for 15mm bore complete
70Supply and fixing stop valves fancy type chromium plated with long shank and cup (concealedtype ) screwed for iron pipe of 15 mm bore
71Supply and fixing PVC connection 15 mm bore, 450 mm long complete with both ends unions.
72Supply and fix 75mm dia PVC (SWR) pipe single socket in any length with rubber ring joint fixed to wall or laid in trenches complete all as specified and as directed.
73Supply and fix 110mm dia PVC (SWR) pipe single socket in any length with rubber ring joint fixed to wall or laid in trenches complete all as specified and as directed.
74Supply and fixing inPVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
75Supply and fixPVC cowl 110 mm dia complete all as specified and as directed.
76Supply and fix 110mm dia PVC bend any radius complete all as specified and as directed.
77All as per item No (76) above but 75mm dia
78Supply and fixing PVC (SWR) bends of any radius with access door bore of pipe 75 mm
79Supply and fixing PVC (SWR)junction single(single T)equal or unequal with access door bore of pipe 110 mm
80Supply and fixing PVC (SWR) reducers 110 mm
81Material and labour for Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in copings/benching of manholes including weathering rounded/chamfered angles and throating as directed including necessary form work. Exposed surfaces of concrete shall be finished even and smooth with out using extra cement.
82Material and labour PCC 1:3:6 type C-1 using (20mm graded stone aggregate) as in hold fast
83Material and labour for Pre-cast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate set in cement mortar 1:4 as in cover slab including all necessary form work. Exposed surfaces of concrete shall be finished even and smooth without using extra cement.(Note : Reinforcement shall be measured and paid separately under relevant items of this schedule).
84Supply and fix vitreous China urinals, Half stall type white (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)complete all as specified and as directed.
85Supply and fixingof 15mm dia concussive push button taps of cast copper alloy, chromium plated screwed for iron pipe and fixed
86Supply and fixing Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (minimum wt 60 gms)
87Sch \"A\" Part II E&M Internal electric works Material and labourfor Point wiring using approved colour coding as per IS ( Red, black and green for single phase circuit ), with 1.5 Sq mm cross sectional area, single core, multi stranded copper conductor (FRLS) PVC insulated and unsheathed electrical cableISI Marked and including medium grade PVC conduit of dia notless than 20 mm and conduit accessories concealed in wall/surface including mild steel/pressed steel sunkun boxes (with earth dolly) dully painted with two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets etc including PVC insulated multi-stranded copper conductor 1.5 sq mm nominalcross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly forLight point controlled by one piano type 5 amp switch complete all as specified and directed by Engr in Chargeat site for the following:- Note - (i) Cost of cutting chasing and making good of disturbed surface all to match with existing surface deemed to quoted rates. (ii) Switch, socket and regulatorto be measured and paid separately in respective items.
88All as per item No 87 but for independent Socket outlet 2 in -1 3 pin, 5 amp flush type
89All as per item No 87 but forsame board Socket outlet 2 in -1 3 pin, 5 amp flush type
90All as per item No 87 but forwith 2.50 Sq mm un-sheathed multistranded cable for one socket outlet 15 Amps independent including continuous copper earth wire, PVC insulated of 2.50 Sq mm size (Switch, Socket shall be measured and paid separately).
91Material and labourfor switch piano flush type 6 Amps 240 volts single pole one way complete.
92Material and labourfor socket outlet 2 in 1, 5 pin, 6 Amps 240 volts complete.
93Material and labourfor switch piano flush type 16 Amps, 240 volts one way.
94Material and labourfor Socket flush type 6/16 Amps, 2 in 1, 240 volts complete all as specified
95Material and labourfor ceiling rose surface Bakelite, 3 terminal complete all as specified & as directed.
96Supply and fixing stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd.
97Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
98Supply and fixing LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder includingLED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose.
99Supply and fixing sheet metal enclosure MCB DB, SPN, 240 volts, 8 way, double door type fixing on PUF insulated panels boards including providing 12mm thick prelaminated board ofsuitable size with 3mm thick TW beading all-round ofboard, necessary holdfast etc and making good of disturbed surfaces matching with existing surfaces and electrical connections as required complete all as specified and directed.
100Supply and fixing LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed..
101Supply and fixingMCB SPN, 240 volts AC 50 Hz,32 breaking capacity 10 KA all as specified and as directed.
102Supply and fixing MCB SP 240 volts, 10 KA, C-Series 6 to 32 Amps complete all as specified & as directed.
103Supply and fixing ,testing commissioning heavy duty Exhaust fan of size 300 mm sweep with louvers including accessories, 6 pole, 900 RPM metal body with frame andsd louvers of suitable size of approved make complete all as specified and directed .Note - Making hole in PUF insulated panels of any size for fixing fan of appropriate size to fix the exhaust fan 300 mm shall be deemed to included in the quoted rate .
104Supply and fix air circulating fan 450 mm 230 volts single phase oscillating complete.
105Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor
106Material and labourfor providing earthing complete with GI earth plate electrode of size 60 cm X 60 cm X 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level, connected to 4 mmdia GI wire by means of bolts, nuts check nuts and washer of GI or steel all as shown in electrical plate No.5 of SSR Pt-I, connected to earthing main switch board/main board including necessary earthwork PCC 1:3:6 type C-1 chamber, precast RCC cover using XPM weighing not less than 4.00 Kg/Sq m in lieu of CI cover, 20 mm bore GI pipe (light grade) for watering and 15 mm bore GI pipe (light grade) for protection of earth lead etc. complete all as specified and directed.
107Sch \"A\" Part III E&M External electric works Supply and lay cable XLPE insulated , Screened, PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 4 core complete all as specified and directed. NOTE- Cable connection and testing should be done by contractor and including in rates.
108Supply and spread dry riddled sand in trenches for cable cushioning all as specified on both top and bottom of cable including ramming all as specified and directed Note:- For the purpose of payment the punned thickness only measured.
109Supply and lay well burnt Bricks, common burnt clay building bricks, sub-class ‘B’ designation for cable protection all as specified and directed.
110Supply and fixing GI tubing light grade 40 mm dia for cable protection fixed along with steel tubularpole / RCC pole/ laying in ground including necessary clamp, nut, bolt, washers etc. all as directed at site.
111Material and labourfor Fabricate supply install test and commissioning of Panel box out door typetotally enclosed dust and vermin proof floor mounting with hinged doors and locking arrangement front and back fabricated out of 3.15 mm thick CRCA sheet for load varying , 2 mm thick non load varying portions protection of enclosure IP-54 as per IS/IEC- 61439 rates with breaking capacity 50 KA with internal Arccontainment with CPRI approvedincluding powder coated paint finish including all accessories, provision independent removable MS plates for fixing cable glands for all incoming and outgoing cables and complete control wiring with 2.5 sqmm copper conductor including necessary PCC foundation complete all specified. Note:- (1)Rates deemed to be included for suitable lugs and glands for incoming and outgoing of LT UG cable. (2) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work. (A) INCOMING. (a) Aluminiumbusbar of capacity 200 Amps with epoxy insulated supports 3 phase and neutral -1 set(b)MCCB 63 Amps 4 pole 16 KA - 01 No Make-Legrand/L&T/Indo Asian (optipro) (B) OUT GOING(a) MCB 32 Amps, Double Pole 10 KA- 03 Nos\"(b) MCB DP 20 Amps - 01 Nos , (c) MCB DP 10 Amps - 02 Nos \" (d ) Volt mtr digital type 96 sqmm with selector switch - 01 set\" (e) Amps mtr digital type 96 sqmm with CT\"s 200/5 -03 Nos and selector switch - 01 Set, (f) Indicating lamp set LED type - 01 set
112Material and labourfor providing earthing complete with GI earth plate electrode of size 60 cm X 60 cm X 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts check nuts and washer of GI or steel all as shown in electrical plate No.5 of SSR Pt-I, connected to earthing main switch board/main board including necessary earthwork PCC 1:3:6 type C-1 chamber, precast RCC cover using XPM weighing not less than 4.00 Kg/Sq m in lieu of CI cover, 20 mm bore GI pipe (light grade) for watering and 40mm bore GI pipe (light grade) for protection of earth lead etc. complete all as specified and directed
113Sch \"A\" Part IV E&M External water supply works Supply and lay pipe galvanized iron, “Medium grade”, including all fittings 50 mmdia fixed complete to wallslaid in trenches.
114Supply and lay pipe galvanized iron, “Medium grade”, including all fittings 40 mmdia fixed complete to wallslaid in trenches.
115Supply and lay pipe galvanized iron, “Medium grade”, including all fittings 25 mm (1”)dia fixed complete to wallslaid in trenches.
116Supply and fix 25 mm size Bib tap cast copper alloy with cructh or butterfly handle screwed for iron pipes or brass ferrule and fixed fancy type complete all as specified.
117M&L for construction of PCC block walling valve pit of size 900mm X 900 mm (internal dimension) with precast cement concrete block of PCC 1:3:6 (PCC 1:3:6) type C-1 using 20 mm graded stone aggregate and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces with and incl 40X40X6 mm mild steel angle iron frame and 3mm thick MS sheet cover thickness not less than 3mm with locking arrangement and 1 No 50 mm size 4 level lock with key in duplicate incl painting to steel and iron surface with two coats of black bituminous paint over a coat of red oxide prime complete all as specified and shown on drawing complete all as specified and directed.
118Material and labour for DI fitting/ specials 100 mm to 300mm dia suitable for spigot and socket end or flanged end such as bends (any type radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc). Tee pieces single branch “Y” junction, double branch, cross, collars, caps and plugs, connecting pieces (any type) and testing complete all as specified and directed.
119Cutting the existing road/ hard standing/ chequered cement concrete tilling/ PCC flooring etc, not exceeding 700 mm wide and 1100mm depth for laying CI/GI/DI pipe line complete including taking online permission from BWSSB if civil road involves all as specified and as directed.
120Material and labour for PCC 1:3:6 type C1 using 20mm graded stone aggregate for making good or where required for the road/ hard standing/ chequered cement concrete tilling/ PCC flooring etc, including necessary form work to exposed surfaces finished smooth and even complete all as specified and as directed.
121Cutting/ drilling the existing cast iron/ ductile iron pipe line of 150mm dia, in position for inserting of new tees, branches etc complete all as specified and directed.
122Supply & fix stop valve fancy type chromimum plated cast copper alloy, screwed down, high pressure , with cruch or butterfly handle screwed both ends for iron pipe or for union of 50mm dia.
123All as per item No 122here in before but 40 mm dia
124All as per item No 122here in before but 25 mm dia
125Supply & fixing ball brass valves 25 mm high pressure with polythene float and fly nut complete screwed for iron pipe.
126Supply & fixing ball brass valves 40 mm high pressure with polythene float and fly nut complete screwed for iron pipe.

AI Tender Summary

OUR REF NO 32408313
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 16-06-2022
Authority
Authority Name Military Engineer Services
Work Description Provision Of Living Accn For Trainees At Cti Af Stn Jalahalli West Under Ge M Af Jalahalli Bangalore
Basic Detail
Tender No 8657/E8
Bidding Type Tender
Location
City jalahalli
State Karnataka
Key Dates
Publish Date 09 Jun 2022
Submission Date 16 Jun 2022
Open Date 18 Jun 2022
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 87600
Exemption Not Available
Document List
4ee80563-8c3d-44da-9063-d91231aad6ca.html
BOQ_588105.xls
GENPAGES8657.pdf
PS8657.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 09, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 16, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 16, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 18, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

4ee80563-8c3d-44da-9063-d91231aad6ca.html

xls

BOQ_588105.xls

pdf

GENPAGES8657.pdf

pdf

PS8657.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender