| 1 | Code No. 17.2.9: Supply and erection MS swaged tublar pole with base plate and foundation bolt & nut and single ornamental bracket two coats of zinc chromate and two coats of aluminium / epoxy painting. Pole height 7.5mt. Pole dimension - 139.7 x 4.50 x 3000mm , 114.3 x 3.65 x 2250mm, 88.9 x 3.25mm x 2250mm bracket dimension 60.3mm x 3.65mm x 2700mm - 1no, base plate dimension 300mm x 300mm x 10mm. with stiffner plate. Overall height 9 mt. Including excavation of earth 750 x 750 x 1500mm and cement concrete 1:2:4 - 750 x 750 x 1500mm for filling and capping above ground level 450mm dia x 600mm height. One coat of zinc chromate and two coat of aluminium/epoxy painting should be done after erection of the pole and inclusive of suitable length 1.50mt.- 2 nos. of 40mm dia medium class GI pipe for cable raising. |
| 2 | NPSR: Supply and fixing of LED street light fitting in existing / New street light arms having 120watts and above (System Wattage), IP 65 / 66 white colour with necessary over voltage, under voltage and surge protection with three years onsite warranty for replacement /Rectification. Make:Philips /Havells /Crompton / Bajaj / LED GEO. |
| 3 | Code No.17.2.11: Fixing testing and commissioning of Sodium vapour/Mercury vapour/Metal halide street light fittings on existing poles as required |
| 4 | Code No.1.7.2: Supplying and drawing of 2.5sqmm FR PVC insulated, copper conductor, single core cable in the existing surface/ recessed, PVC/steel conduit/PVC casing and capping as required Make: Finolex / Polycab |
| 5 | Code No.2.10.1: Supplying and fixing 6 amps to 32 amps rating ,Single pole,240 volts,\"c\" series,miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:ABB/L&T Hager |
| 6 | NPSR: Supplying of 4 x 16sqmm of armoured aluminium U.G cable – 1.1KV grade. (Make – Finolex / Polycab). |
| 7 | NPSR: Supplying of 4 x 25sqmm of armoured aluminium U.G cable – 1.1KV grade. (Make – Finolex / Polycab). |
| 8 | Code No.7.1.1: Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of sizenot exceeding 25sq.mm direct in ground including excavation, sand cushioning,protective covering and refillilng the trench etc as required Mud Road |
| 9 | Code No.9.1.33: Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of sizenot exceeding 25sq.mm direct in ground including excavation, sand cushioning,protective covering and refillilng the trench etc as required Bituminous Road |
| 10 | Code No.9.1.34: Supplying and making end termination with copper gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade as required:4 X 16 Sq.mm |
| 11 | NPSR: Supply and fixing of 40mm dia. green spring hose |
| 12 | Code No.2826: Supply and laying of 40 mm dia. GI pipe medium class |
| 13 | Code No.31.263.1: Making earth pit of G.I pipe for earthing in earth pit with 40mm dia.G.I pipe medium class of length 3.05 perforated with 46 Nos. of 12mm dia holes, pipe lowered in bore holes of 150mm dia.and filled in with charcoal and salt in alternative layer of 300mm, the top of G.I pope shall be clamped.Earth pit shall be provided with 60cm dia precast ring with 60cm depth alround, covered with R.C.C precast slab etc. As per I.E.standards. |
| 14 | Code No.2904: Supplying of 8 SWG copper wire (4.0 mm dia) |
| 15 | Code No. 31.262.1:Supplying and fixing of teak wood aerial board with 100 Amps HRC fuse base and fuse link and suitable post clamp to hold to G.I pipe with electric post including bolts and nuts etc., complete. |
| 16 | NPSR: Fabrication, supply, erection, testing and commissioning of one no of Timer and metering panel board for the power supply of over all size 1100mm x 650mm x 250mm made out of 16SWG thick cold rolled M.S. Sheet. The front side compartment have energy meter with viewing glass with 10mm hylem sheet. The back side compartments with 40 – 63A rating, TPN MCB, “C Series, 10KA breaking capacity (Make – Siemens/ABB), 1no. of Timer switch (Daily) analog with battery backup to 200hrs. (Make – L&T – Hagger/ Legrand - Lexic), 1no. 60A power contactor (Make – C&S), 1no. of toggle switch (Make – C&S), 3nos of signal lamp (Blue, Red, Yellow). (Make – Siemens/C&S/ L&T/Teknic). The switch units are to be fixed with in the allotted size in the 10mm hylem sheet. The bottom sheet of the shell should be of 16SWG thick cold rolled M. S. Sheet with brass gland for cable entry. The panel has to be mounted on the floor with in the height of 375mm.Interior connection between the switch fuse units are to be done with 10.0sqmm ISI marked, FR PVC insulated, single core copper conductor cable. (Make – Finolex / Polycab). The door should be of flush type inter locking in one position. The panel provided with removable type gland plated to the bottom and with sufficient holes of required diameter. The panel should be painted with two coats of rust proof Zinc chromate and two coats of anti corrosive epoxy shade 631 siemens grey paint after completion of de-rusting process. Earth work excavation of foundation stench of size 1.00mx0.45m x0.60m and filling river sand for a depth of 10cm and P.C.C. 1:2:4 of size 1.00m x0.45m x 0.50m. The cost should be inclusive of minor modification suitable for site condition as approved by the engineer – in – charge. |
| 17 | Code No.15.2.1: Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead - nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 18 | NPSR: Supply,Fixing and wiring of MS rod earthing wih 20mm dia MS rod for all street lighting poles as per te standard practice including interconnecting GI wire upto earthing terminal of the pole. |
| 19 | NPSR: Supply and laying Doubled walled corrugated (DWC) HDPE Duct of size 50/39 mm conforming to IS:14930 etc,complete as directed by the Engineer-in-charge. |
| 20 | NPSR: Supply and fabrication ofinbuilt box with cable entry IP-65 junction box with coveras directed by Engineer-in-charge. |