Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #32369321

Mainte / Rep Of Ext Elect, Panels, Mccbs, Street Lights And Connected Allied Wks At Phase Alongwith Repair / Maintenance And Replacement Of External Water Supply Pipe Lines And Connected Wks At Ph As Above

Issued by Statutory Bodies & Commissions/Committees · TENGA VALLEY, Arunachal Pradesh
Tender Value
47 Lakhs
Estimated cost
Bid Submission
11 Jun 2022
0 days left
EMD
94000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
TENGA VALLEY → Arunachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Mainte / Rep Of Ext Elect, Panels, Mccbs, Street Lights And Connected Allied Wks At Phase Alongwith Repair / Maintenance And Replacement Of External Water Supply Pipe Lines And Connected Wks At Ph As Above

BOQ

Nature of Work: Repair/ Maintenance/ Replacement of external electrification, Panels, MCCBs, Street Lights and connected allied wks at Phase-III (Dahung Area) alongwith Repair/ Maintenance and replacement of external water supply pipe lines and connected wks at Phase-I (Rupa Area) under GE 859 EWS
Sl. No. Item Description
1Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out in hard / dense soil for laying of cable / errection of poles / stay assembly etc complete all as specified anddirected.
2All as per item No. 1.00 above but depth exceeding 1.5 m and not exceeding 3 m complete all as specified and directed.
3Returning filling in trenches including spreading, leveling, watering and well ramming in layers n . Exc 25 cm complete all as specified and directed.
4Removing surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
5M&L for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole,stay assembly, repairs to road cutting etc complete all as specified and directed.
6M&L for PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed
7Dismentling /taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismentling ends from OH conductors/MCCBs/Joint boxes for relaying/refixing or carrying to store for Sch of Credit.
8Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 50 Sqmm 3.5 core with required aluminium cable lugs all as specified and directed.
9All as per item No. 8.00 here-in-before but 70 Sqmm 3.5 core complete all as specified and directed.
10All as per item No. 8.00 here-in-before but 95 Sqmm 3.5 core complete all as specified and directed.
11Supply and spreading clean dry river sand in trenches for cushioning of UG cables complete all as specified and directed.
12Supply and laying in replacement un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection complete all as specified and directed.
13Dismentling taking out broken/worn out steel pole of 8.5 to 9.0 mtr long and kepping aside for refixing or carrying to store for credit
14M&L for steel tubular swaged pole complete with cast ironbase plate , finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410 SP-31 (9 Mtr long).
15Dimentling and taking down old/unsv insulator of any type any size from pole/stay complete all as specified and directed.
16S&F pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade all as specified and directed.
17S&F 1100 volts grade heavy dutyflat twin core cable PVC insulated with stranded aluminium conductor of size 10 sqmm and overall PVC sheathedin service connectionsincl dismentling taking down unserviceable one all as specified and directed.
18S&F 1100 volts grade heavy dutyflat twin core cable PVC insulated with stranded aluminium conductor of size 16 sqmm and overall PVC sheathedin service connectionsincl dismentling taking down unserviceable one all as specified and directed.
19S&F MCCB 250 Amps 4 Pole, 36 KA, 415 V, 50 Hz and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
20All as per item No 19 here in before but MCCB 200 Amps 4 Pole, 36 KA, 415 V, 50 Hz complete all as specified and directed.
21All as per item No 19 here in before but MCCB 100 Amps 4 Pole, 36 KA, 415 V, 50 Hz complete all as specified and directed.
22M&L for trimming of branches of trees touching LT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height 7 mtr and above and carrying and depositing where directed not exceeding 50 mtr.
23Dismentling taking down carefully flood/stree/gate light fitting any type any make any capacity from pole, gate pillar or wall complete all as specified and directed.
24S&F LED Street light fitting 25 Watt new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver.
25S&F LED Street light fitting 45 Watt new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver.
26S&F LED Street light fitting 60 Watt new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver.
27S&F energy saving environmental friendly, long life exclusive innovative die-cast aluminium IP-66LED flood light of 60 Watt 5700Kwith high power LED as light source source complete all as specified and directed.
28S&F energy saving environmental friendly, long life exclusive innovative die-cast aluminium IP-66LED flood light of 180 Watt 5700Kwith high power LED as light source source complete all as specified and directed.
29S&F Street light junction box of size 200mm x 140mm x 95mm outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable/wire complete comprising with the followings :- (a) Bus bar with two aluminium strips, 63 Amps capacity insulated with insulators, including colour coding, including PVC cable of suitable size from bus bar to MCB(b) MCB SPN 5 to 30 Amps - 01 No (c) Clamps made out of 25mm x 3mm flat iron duly weldedwith nuts & bolts incl dismentling taking down unsv complete all as specified and directed.
30S&F On load change over switch, four pole with advance neutral 63 Amps, 415 V, 50 Hz conforming to IS : 13947 Part-3 connecting up in separate SS enclosure including taking out existing unserviceable change over switch complete all as specified and directed by Engineer-in-charge.
31S&F On load change over switch, four pole with advance neutral 200 Amps, 415 V, 50 Hz conforming to IS : 13947 Part-3 connecting up in separate SS enclosure including taking out existing unserviceable change over switch complete all as specified and directed by Engineer-in-charge.
32Supply only distilled water
33S&F for replacement of battary 12 V Low maintenance lead acidsuitable forsolar street light having minimum backup of 3 daysMake : Exide/Amaron or equivalent of approved make.
34S&F Heating element 3/2 KW for electrical backup with rubber washers suitable for solar water heater 1000/500/100 LPDincl dismentling taking down unsv one all as specified and directed.
35M&L for design, fabricate, supply, testing and commisioning of CPRI approved factory made LT Panel Board double door, out door type fabricated out of 3.15mm thick CRCA sheet steel for outer body and 2.00mm thick CRCA Sheet for inner partition walls, independent cabinate with cabinate doors for MCCBs, Bus Bars, cable trays, metering equipment,vertical type floor mounted on angle iron frame of ISA 45x45x5mm with minimum height of legs 45 cm, minimum IP-54 protection, comprising of solid aluminium bus bar 4 strips suitable of 600 Amps, suitablily grouted to PCC complete with internal wiring, epoxy powder coated,dismantling of all connections and re-connection of cable ends with suitable size of aluminium cable lugs with the following accessories.Make of MCCB- Havells / L&T / Legrand / Schneider(a) INCOMING(i) MCCB 250 Amps, 4 Pole, 415 V, 36 KA - 01 No(b) OUTGOING(i)MCCB 100 Amps, 4 Pole, 415 V, 25 KA - 04 Nos(ii) Digital voltmeter of size 4\"\"x4\"\"--01 Nos(iii) Digital ammeter of size 4\"\"x4\"\"--01 Nos(iv) Selector Switch for Ammeter/Voltmeter-02 Nos(v) Current Transfer (CT) --03 Nos(vi) Phase Indicator Lamp (RYB) set of three-01 Nos
36Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out in soft/ disintegrated rocks complete all as specified anddirected.
37S&F GI tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, 20mm bore with and including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches/floor/under culvert/road crossing etc, fixed as in repair including dismentling taking down old unserviceable one complete all as specified and directed.(Note: Exacavation and earhwork shall be measured and paid for separately.)
38All as per Item no 37 here-in-before but of size 25mm bore ditto.
39All as per Item no 37 here-in-before but of size 40mm bore ditto.
40All as per Item no 37 here-in-before but of size 50mm bore ditto.
41All as per Item no 37 here-in-before but of size 80mm bore ditto.
42S&F 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV 90mm outer diameter stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random complete fittings as per site requirement fixed and laid in trenches/floor/under culvert/road crossing etc, fixed as in repair including dismantling taking down old unserviceable one complete all as specified and directed.(Note: Excavation and earthwork shall be measured and paid for separately.)
43All as per Item no 42 here-in-before but of size 110mm bore ditto.
44S&F in repair PP-R gate valve heavy duty suitable for 90mm outer bore PPR pipe with iron wheel head screwed both end as per site requirement.
45S&F in repair PP-R gate valve heavy duty suitable for 110mm outer bore PPR pipe with iron wheel head screwed both end as per site requirement.
46S&F Bronze gate valve for 15mm bore pipe,with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778 : 1984, fixed as in repair including dismantling taking down old unserviceable one complete all as specified and directed.
47All as per Item no 46 here-in-before but of size 20mm bore ditto.
48All as per Item no 46 here-in-before but of size 25mm bore ditto.
49All as per Item no 46 here-in-before but of size 40mm bore ditto.
50All as per Item no 46 here-in-before but of size 50mm bore ditto.
51S&F cast iron air release valve, nominal size DN-150mm, strandard type heavy duty suitable for PN-1.6 pressure water pipe line including suitable size joints and jointing material, fixed as in repair including dismantling taking down old unserviceable one complete all as specified and directed.
52Supply and fixing cast iron Sluice valve PN 1:6 as per IS-14846, body, dome, wedge-CIIS:210, rings bronze IS:318, Spindle-SS IS-6603, Gland Packing gresy jute packing, fasteners-CS, Gasket-Natural rubber, Nominal size DN-150mm, both ends flanged in existing line without damaging to existing pipe line, fixed as in repair including dismentling taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. Note :- Suitable size flanges for existing pipe line, joints and jointing material shall be included under this item.
53All as per Item no 52 here-in-before but of size 100mm bore ditto.
54All as per Item no 52 here-in-before but of size 80mm bore ditto.
55Supplying, fixing and testing of cast iron swing check non returnvalvePN 1.6 as per IS 5312 part I,body, dome, wedge - CI, IS 210, rings bronze,IS:318, Door - CI IS:210,Door face - natural rubber Gland packing gresy jute packing, fasterner,CS, gasket - Natural rubber, nominal size DN - 150 mm both ends flanged complete all as specified and as directed. Note-: Suitable size flange, joints and jointing materials shall be included under this item.
56All as per Item no 55 here-in-before but of size 80mm bore ditto.
57Taking out old unserviceable with replacement of ball bearing 7311-BECBP, completeall as speciified and as directed. Make: SKF/ NBC
58Supplying, fixing and testing of Foot Valve PN 1.6 as per IS 5312 part I, nominal size DN - 150 mm single end flanged complete all as specified and as directed. Note-: Suitable size flange, joints and jointing materials shall be included under this item.
59All as per Item no 58 here-in-before but of size 100mm bore ditto.
60M&Lfor PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in concrete pedestal for supporting the CI/GI pipes including necessary form workincluding demolition of existing pedestal complete all as specified and directed.

AI Tender Summary

OUR REF NO 32369321
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47 Lakhs
LAST DATE 11-06-2022
Authority
Authority Name Military Engineer Services
Work Description Mainte / Rep Of Ext Elect, Panels, Mccbs, Street Lights And Connected Allied Wks At Phase Alongwith Repair / Maintenance And Replacement Of External Water Supply Pipe Lines And Connected Wks At Ph As Above
Basic Detail
Tender No T/8328/E8/22-23
Bidding Type Tender
Location
City TENGA VALLEY
State Arunachal Pradesh
Key Dates
Publish Date 24 May 2022
Submission Date 11 Jun 2022
Open Date 13 Jun 2022
Finance
Tender Value 47 Lakhs
Tender Fee 500
EMD 94000
Exemption Not Available
Document List
TENDER8328.pdf
Tendernotice_1.pdf
4c378138-0a0a-40fb-9ef0-30e165bdd49c.html
BOQ_587948.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 24, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 11, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 13, 2022

Bid Opening Date

Technical bids will be opened and evaluated.