| 1 | M & L for comprehensive maintenece and servicing ofSplit type Air conditioner/Window type unit of any capacity outer and inner unit both of any make including cleaning the dust frombody with blower, cleaning of condenser and cooling coil, checking all connections including functioning of metal clad socket/DP switch, function of relay, capacitors, overload protector, thermostat, fan motor,fan/blower drum, main control board PCB, electronic contol box, etc, oiling/greasing of fan motor, checking serviceability, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of worn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioningall as specified and directed by Engineer-in-Charge.(Note: Spares parts replaced shall be measured & paid under saperately under relevant items here-in-below) |
| 2 | All as per Item No. 1 above, but for Water cooler/Deep freezer/Refrigerator of any type and any capacity |
| 3 | Supply only starting capacitor 80-100mfd for AC, water cooler, Refrigerator, deep freezer etc all as specified and directed. |
| 4 | Supply onlyrunning capacitor 10MFD |
| 5 | Supply onlyrunning capacitor 36MFD |
| 6 | Supply Only running capacitor 50MFD |
| 7 | Supply Only running capacitor 60MFD |
| 8 | Supply onlyblower motor capacitor 4MFD to 6MFD |
| 9 | Supply only starting relay suitable for water cooler,AC, and refrigerator, deep freezer for any make and model opreated on single phase 230 volts all as specified and directed. |
| 10 | Supply Only for over load relay comprising of over load protection suitable for air contioner, water cooler, deep freezer and refrigerator opreated in single phase 230 volt all as specified and directed. |
| 11 | Supply only themostat switch suitable for Air conditioner,water cooler, deep freezer and refrigerator operated on single phase 230 volts supply all as specified and directed. |
| 12 | Supply only drier filter for AC, water cooler and refrigerator. |
| 13 | Supply only magnetic contactor as in outer unit of Split type air conditioner as per existing type complete all as specified and directed. |
| 14 | Supply Only capillary tubes for the following :- |
| 15 | Air Conditioner1.5 ton /2 ton and Water cooler 40 to 150 ltr |
| 16 | Refrigerator & Deep freezer upto 400 ltr |
| 17 | Supply only indoor fan motor of split type AC of any capacity |
| 18 | Supply OnlyCondensor fan motor 1300rpm, 1/6Hp, 1/8Hp, 1/10Hpfor Split type Air Conditioner outdoor unit of 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and directed by Engineer In Charge |
| 19 | Supply OnlyCondensor fan motor double shaft1/6Hp, 1/8Hp, 1/10HpforWindow type ACof 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and directed by Engineer In Charge |
| 20 | Supply OnlyCondensor fan motor1/36Hp forWater Coolerof 40-80Ltr and deep freezer upto 400Ltr as per existing make and capacity all as specified and directed by Engineer In Charge |
| 21 | Supply OnlyCondensor fan motor1/6Hp, 1/8Hp, 1/10Hp forWater Coolerof 120-150Ltr as per existing make and capacity all as specified and directed by Engineer In Charge |
| 22 | Supply only blower/condensor fan blades as per existing make & type for Air conditioner/Water cooler/deep freezer all as specified and directed. |
| 23 | Supply, install, test & commissioning hermatically sealed new compressor for Split type AC of capacity 1.5TR duly charged withfresh freon gasetc complete all asspecified/directed by Engineer-in-Charge including taking down old u/s compressor.Make:- Voltas/Shriram/LG/Godrej/Kirloskar or as per existing make at site. |
| 24 | All as per item No.21 above, but for split type AC of capacity 2.0 TR |
| 25 | All as per item No.21 above,but for Window type AC of capacity 1.5TR |
| 26 | All as per item No.21 above,but forWindow Type AC of capacity 2.0TR |
| 27 | All as per item No.21 above, but for Water Cooler of capacity 40 to 80Ltr |
| 28 | All as per item No.21 above, but for Water Cooler of capacity 120 to 150Ltr |
| 29 | All as per item No.21 above, but for Refrigerator 165 to 210Ltr Capacity |
| 30 | All as per item No.21 above, but for Refrigerator 286 to 310Ltr Capacity |
| 31 | All as per item No.21 above, but for deep freezer 298 to 310 ltr capacity |
| 32 | M & L for detecting the gas leakage, rectifying the defects including repair to condensor coil/evaporator coil by means of welding, soldering etc, vacumizing and charging, topping up fresh freon Gas and commissioning and testing for the 1.5Ton/2.0ton split type/window type AC all as specified and directed by Engineer In Charge |
| 33 | All as per item No. 30 above, but of water cooler, refrigerator & deep freezer of any type and any capacity |
| 34 | Supply and replace remote control unit of Split type AC1.5 ton/2.Ton including making frequency arrangement of new remote with existing system all as specified and directed by Engineer In Charge |
| 35 | Supply only Electronic PCB unit for main control panel of Split type/Window type AC of any capacity all as specified and directed. |
| 36 | M&L for dismantling of existing unserviceable voltage stabilizer for repairs including replacement of relays , electronic voltage sensor circuits and meter, micro switch , indication light RC fitters and other connected items for making functional as per the entire satisfaction of Engr-in-charge and rewinding of unserviceable transformer with super enamelled copper wire of appropriate size , varnishing assembling and testing complete for following capacities:- |
| 37 | Upto 1 KVA |
| 38 | Upto 2 KVA |
| 39 | Upto 4 KVA |
| 40 | Upto 5 KVA |
| 41 | M&L for dismantling of existing unserviceable power UPS for repairs andreplacement of unserviceable parts likerelays , electronic voltage sensor circuits, meters, micro switch , indication light RC fitters, rectifiers, transformers as per existing capacity and specifications and other connected items for making functional as per the entire satisfaction of Engr-in-charge and testing complete for Capacity upto 5KVA |
| 42 | Disconnecting electrical / mechanically and lowering to the ground for repairing / over hauling the desert cooler including replacement of canvas grass / wood wool pads and spray painting to body with one coat of anti corrossive red oxide primer for any make of desert cooler to make it fully functional including replacement of unserviceable/defective spare parts, transportation to and fro, re-installation and testing on completion to the entire satisfaction of Engineer -in - chargeNote : Spares replaced will be measured and paid under saperate Item |
| 43 | Supply only water lifting pump 1/70 HP capacity , operated on single phase 230 volts with all accessories and testing complete to the entire satisfaction of Engr -in-charge. |
| 44 | Supply only fan motor of desert cooler of any capacity includingsupporting legs , nuts and bolts etc. |
| 45 | Supply only fan blade with bush for desert cooler motor |
| 46 | Supply only selector switch/rotory knobfour way suitable for desert cooler as per existing size and make |
| 47 | Supply only electronic control circuit board (PCB) as per existing type for desert cooler. |
| 48 | Supply only swing motor for air cooler |
| 49 | S & F in repair Metal Plug Tops for 2Pin and earth socket AC Box of capacity 240V, 20A all as specified and directed |
| 50 | Supply OnlyPVC flexible pipe 25 mm dia as in drain pipe suitablefor water cooler outlet |
| 51 | S&F in repair connecting sheet metal enclosure with two pin and earth plug and socket complete, with one double pole MCB20 Amp Make : Havells/ Standard/ HPL. |
| 52 | S&F in repairs Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for 15mm bore. |
| 53 | S & F in repair Push tap Self closing taps of size 15mm of cast iron or malleable cast iron, galvanised, screwed for iron pipe or for water cooler |
| 54 | Supply and fix PVC connecting pipe with brass nuts and washers at both ends of length not exceeding 60 cms for connection of water coolers including taking down old pipe |
| 55 | M&L for wiring for circuit /sub main wiringwith earth wire of size 2x 4.0sqmm + 1 x 2.5sqmm of FR PVC insulated copper conductor, single core cable in surface drawing in and includingPVCcasing capping. |
| 56 | M&L for wiring for circuit /sub main wiringwith earth wire of size 2x 2.5sqmm + 1 x 1.5sqmm of FR PVC insulated copper conductor, single core cable in surface drawing in and includingPVCcasing capping. |
| 57 | Taking down unserviceable/damaged Sub main wiring any type any size including continuous earth wire, conduit/casing and making good disturbed surfaces of walls/ceiling matching with existing tint. |
| 58 | M&L for point wiring for light/fan/Bell with FRLS cable 2.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/capingwith all accessories and 2.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly inclPVC box surface/ flush type with PVC sheet for mounting fittings such as switches, sockets, fan regulators,etc complete all as specified and directed for multipin 15 amps socket outlet flush type on independent board controlled by one switch & making goodto disturbed surface of wall etc all as specified and directed. |
| 59 | M & L for Framed work such as grills, gratings, etc. for water tanks, water cooler stand, AC Unit supports, UPS Battery Stand and similar work conforming to Fe.290.Gde-E-165 with two coat of synthetic enamel paint over one coat of red oxide primer including preparation of new steel surface incl taking down old unsrviceable one all as directed and specified by Engineer In Charge |
| 60 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA.wall mounted. |
| 61 | M & L for repair/replacement tostainless steelwaste water tray including welding, polishing, riveting, provision of fixing screws and refixing. |
| 62 | S & F in repair forGaskets for top cover forwater cooler of any capacity and make as per site requirement. |
| 63 | M & Lforreplacement damage cooling coil for refrigerator of capacity 210/300 ltrs |
| 64 | M & L for replacement damage condensor coil for refrigerator of capacity 210/300 ltrs |
| 65 | Supply Only door switch for refrigerator of any type and any capacity |
| 66 | Supply only pigmy lamp (indoor lamp) as per existing type for refrigerator |
| 67 | Supply only fridge door as per existing make and type for refrigerator |
| 68 | Supply only timer switch assembly for refrigerator as per existing for capacity 210 to 300Ltrs |
| 69 | M & L for carry out routine maintenance and servicing of Package type air conditioner of capacity 8.5TR & 11TR including removing the dust frombody with blower, cleaning the condenser and cooling coil, checking all the electrical and refrigeration piping connections, checkingfunction of relay, capacitors, overload protector, thermostat, fan motor, blade, fan/blower drum, LT Control panel, VFDs,electronic control box, etc, oiling/greasing of fan motor, checking serviceability, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of worn out/unserviceable spares including taking down and refixing, transportation to and fro workshop if required and refixing it in its original place after fully servicing including testing & commissioningall as specified and directed by Engineer-in-Charge.Note: Spare parts replaced shall be measured & paid under saperate item |
| 70 | Supply only V-Belt Type 13x813A 32A840EL for Blower fan of Package AC Unit of Capacity 8.5TR/11TR |
| 71 | Supply only relay HP & LP for package type AC plant of capacity 8.5TR |
| 72 | Supply only relay HP & LP for package type AC plant of capacity 11TR |
| 73 | Supply only condensor fan motor , 230V,50Hz 920rpm 1/3Hp for package type AC,Model: 14B606A1E/2L-FP7 Make: Micro Instrument Co. or equivalent |
| 74 | Supply & fixing in replacement including connection 3 pole AC power contactor, 32 Amps, 415 Volt with auxilliary contact 1NO + 1NC, having coil voltage 380 to 400 Volts Make: Seimens cat refC4NE22 or equivalent of L &T/Havells. |
| 75 | Supply, fixing and connecting in replacementintegrated circuit board with all electronic components suitable for 8.5 TR capacity Carrier Pakage type Air conditioner. |
| 76 | Supply, fixing and connecting in replacementintegrated circuit board with all electronic components suitable for 11 TR capacity Carrier Pakage type Air conditioner. |
| 77 | Supply, fixing and connecting in replacement SPPR Circuit board suitable for 8.5TR/11TR cap Package AC of Make Carrier. |
| 78 | Supply and fixing in repair 3 Phase, 415V, 50Hz compressor of capacity 11TR suitable for package type AC |
| 79 | Supply and fixing in repair 3 Phase, 415V, 50Hz compressor of capacity 4.25TR suitable for package type AC |
| 80 | All as per Item No. 63 here-in-before, but for carry out repair/maintenance of 3 Phase, 415V, 50Hz Ductable type ACindoor and outdoor unit of capacity 8.5TR complete all as specified and as direted by Engineer In Charge. |
| 81 | Supply and fixing in repairs condensor drain pump of ductable type AC of capacity8.5TR |
| 82 | Supply and fixing in repairs condensor fan motor suitable for ductable type AC of capacity8.5TR |
| 83 | Supply and fixing in repairs fan blade suitable for outdoor unit of capacity 8.5TR ductable AC |
| 84 | Supply and fixing in repairs Blower Motor suitable for Carrier Make Ductable type AC of capacity 8.5 TR |
| 85 | Supply and fixing in repairs Direct driven forward curved type centrifugal Blower fan suitable for Carrier Make Ductable type AC of capacity 8.5 TR |
| 86 | Supply and fixing in repair Electronic PCB Kit for control panel suitable for Carrier Make Ductable type AC of capacity 8.5 TR |
| 87 | Supply and fixing in repairs compressor 3Ph, 415V, 50Hz of capacity 8.5TR for carrier make ductable Air conditioner |
| 88 | All as per Item No. 63 here-in-before, but for carry out repair/maintenance of 3 Phase, 415V, 50Hz Ceiling Mounted Cassette type ACindoor and outdoor unit of Capacity 4.0TR complete all as specified and as direted by Engineer In Charge. |
| 89 | M & L for replacement of condensate drain pump assembly of cassette type AC of capacity 4.0TR |
| 90 | Supply and fixing in repairsSensor unit for water pump of carrier make cassette type ACindoor unit (as per existing). |
| 91 | Supply and fixing in repairs Condensor fan motor suitable for cassette type AC of capacity 4.0TR |
| 92 | Supply and fixing in repairsFan blade made of HD PVC suitable for Carrier make cassette type AC of capacity 4.0TR outdoor unit incl lock nut. |
| 93 | Supply and fixing in repairs Blower Motor/Indoor fan motorsuitable for Carrier Make cassette type AC of capacity 4.0 TR |
| 94 | Supply and fixing in repairs Electronic PCB Kit for control panel suitable for Carrier Make cassette type AC of capacity 4.0 TR |
| 95 | Supply and fixing in repairs compressor 3 Phase, 415V, 50Hz of capacity 4.0TR for carrier make cassette type Air conditioner |
| 96 | Supply and fixing in repairs three phase 3 Phase, 415V, 50Hz overload protection relay suitable for ductable/cassette AC. |
| 97 | Supply and fixing ofAir brake power contactor 3 phase AC 50 Hz 415V, 15Amps (as per existing) suitable for 4.0 TR casette type Air Conditioner. Make: Siemens/C&S/L&T/BCH |
| 98 | Supply and fixing in repair single phase preventor relay suitable for ductable/cassette AC. |
| 99 | M & L for detecting the gas leakage,rectifying the defects including repair to condenser coil/evaporator coil by means of welding soldering etc vacumizing and charging topping up fresh freon gas commissioningand testing for the 11 TR pakage type AC . |
| 100 | All as per Item No. 93 above, but for 4.25TR Compressor of 8.5TR Package type AC plant. |
| 101 | All as per Item No. 93 above, but for 8.5TR Compressor of ductable type AC. |
| 102 | All as per Item No.93 above, but for 4.0TR Compressor of ceiling mounted ductable type AC. |
| 103 | M & L for fixing, installing and testing split type air conditioner on wall including inner and outer unit and neccesary copper pipe work and core cutting required and top up the refrigerant gas required all as specified and directed by Engineer in charge. Additional copper pipe and refrigerant gas required shall be deemed into quoted rate. |
| 104 | M&L for removing the spilt type air conditioner from existing location/wall including inner unit and outer unit both with copper pipe and its electrical connections then holes to be covered with POP all as directed and specified by Engineer-in-charge. |