| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: |
| 2 | All kinds of soil @80% |
| 3 | Ordinary rock @20% |
| 4 | All kinds of soil |
| 5 | E/W in bulkexcavation for foundation trenches by manualmeans over areas not exceeding 1.5 m in width ,1.5 m in depth or 10 sqm in plan in all kinds of soil |
| 6 | Laying and fitting of G.I. pipes (all classes) complete including cost of pipe specials and excluding cost of Pipes and Earth work. |
| 7 | 15mm dia G.I pipes |
| 8 | 20mm dia G.I pipes |
| 9 | 25mm dia G.I pipes |
| 10 | 40mm dia G.I pipes |
| 11 | 50mm dia G.I pipes |
| 12 | 65 mm dia GI pipes |
| 13 | 80mm dia G.I pipes |
| 14 | 100mm dia G.I pipes |
| 15 | Demolishing brickwork manually incl.stacking of serviceable material and disposal of cement mortar |
| 16 | Brickwork with common burnt clay in 1:6 mix |
| 17 | Extra for brickwork above plinth level |
| 18 | Providing and fixing of MS surface boxes (0.75x0.75x0.75) of 6mm thick plate for sluice valves. The job includs fixing of angle iron frame legs in cement concreate 1:2:4 mix with locking arrangements complete. |
| 19 | P/F of DI sluice valves with cap of approved make ISIcomplete with nuts,bolts,washers,rubber insertions etc complete job conforming to IS 14844 |
| 20 | 80 mm dia sluice valve class 1 |
| 21 | 100 mm dia sluice valves class 1 |
| 22 | 150 mm dia sluice valves class 1 |
| 23 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) |
| 24 | 25 mm nominal bore |
| 25 | 40 mm nominal bore |
| 26 | 50 mm nominal bore |
| 27 | 65 mm nominal bore |
| 28 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 29 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately). |
| 30 | 50 mm dia double acting |
| 31 | 80 mm dia double acting |
| 32 | P/F of MS bends,Tees including carriage of welding machine upto site of workand fixing at site including cost of rubber washers,gaskets,nuts and bolts etc complete job |
| 33 | P/F of MS lid of size 0.60mx0.60m of 50x50x6 mm anglesection with 3 mm thick MS lid incl. all locking arrangements ,handles etc complete job |
| 34 | P/F of MS ladderof reqd height made of 50x50x6 mm anglewith 40x40x5 mm thick treads etc all complete job |
| 35 | P/F of 10mm to 12 mm thick flangesto GI Pipesincl.cost of rubber washers,nuts,bolts all works complete job incl carriage of welding machine involving welding at site as per the ground profile |
| 36 | 65 mm GI |
| 37 | 80 mm GI |
| 38 | 100 mm GI |
| 39 | Providing and laying stone soling hand packed in horizonalal on level quarry. |
| 40 | Providing & Laying in position cement concrete of 1:4:8 (1 cement :4 coarse sand : 8 graded stone aggrigate 40mm nominal size)exclding the cost of centring and shuttering all work upto plinth Level. |
| 41 | Random rubble masonry with hard stonein foundation and plinthincl levelling up with cement concrete 1:6:12 mixwith 20 mm nominal size aggregates .All works upto plinth level |
| 42 | P/L in cement concrete in retaining walls,return walls,walls(any thickness)incl. attached pilasters,columns,piers,abuts,pillars upto floor v level in 1:3:6 mix with 20 mm nominal size aggregates |
| 43 | P/L of hand packed stone backingof reqd size complete |
| 44 | P/L of PVC Pipes 80 mm dia acting as weep holes in RRM masonry |
| 45 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 46 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 47 | Reinforced cement concrete work in beams,suspended floors, girdersupto floor v level in 1:1.5:3 mix with 20 mm stone aggregates excluding cost of centring and shuttering ,finishing and reinforcement all complete |
| 48 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 49 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 50 | Foundations, footings, bases of columns etc. for mass concrete. |
| 51 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 52 | columns,pillars,posts,piers etc |
| 53 | Edges of slabs |
| 54 | ,suspended floors,roofs,landings |
| 55 | Beams,lintel beams,girders,bressumers,cantilevers |
| 56 | Extra for shuttering in circular work @ 20% of respective centring and shuttering items |
| 57 | Foundations, footings, bases of columns etc. for mass concrete. |
| 58 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 59 | Edges of slabs |
| 60 | ,suspended floors,roofs,landings |
| 61 | Beams,lintel beams,girders,bressumers,cantilevers |
| 62 | Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.(1 kg of water proofing material in 50 kg of cement) |
| 63 | Providing fixing of PGI Sheet strips at construction joints:-150mm dia wide |
| 64 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 65 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 66 | Providing fixing of MS pipe 150mm dia 5mm thickfor wash outincluding providing fixing of flanges, welding charges and all carraiges complete. |
| 67 | 12mm Cement plaster of mix:1 : 4 ( 1 cement : 4 fine sand) |
| 68 | 15 mm thick cement mortar plaster in 1:6 mix |
| 69 | P/F of double scaffolding for outer side of existing OHTs complete incl all carriages and removal of scaffolding |
| 70 | Woodwork in frames of doors,windows,clerestorey windowsand fixing in position with hold fasts,lugs or with dash fasteners of required dia and length inKD/ Silver |
| 71 | P/F of panelled or panelled and glazed shutters for doors,windows,clerestorey windows and fixing with butt hinges of reqd sizes alongwith necessary screws excluding panelling (whichwill be paid separately) in KD/ Silver |
| 72 | P/F of panelling or panelled and glazed shutters for doors windows,ventilators with grade I type II IS:14587 with 4 mm thick glass panes weighing not less than 10 Kgs/sqm |
| 73 | P/F of 12 mm thick pre laminated particle board (decorative lamination on both sides) grade Imedium density flat pressed three layerparticle board FPT-Ibonded with BWP synthetic adhesive as per IS-848 |
| 74 | P/F of poplar wood for truss work for purlins,rafters,tie beams struts including all sorts of fixtures and fastenings complete |
| 75 | Providing corrugated GS sheet roofingincl vertical/curved surface fixed with polymer coated J or L hooksbolts and nuts 8 mm dia. With bitumem or GI limpet washers or with GI limpet washers filled with white lwad incl a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete excl. cost of purlins ,rafters and trusses complete and incl cutting to size and shape whereever reqd in 0.50 mm thich with zinc coating not less than 275 gms/sqm |
| 76 | Providing matting for chowkidar quarter incl. all carriages |
| 77 | Superior type matting |
| 78 | Cushions |
| 79 | Superior type blankets |
| 80 | P/F of aluminium fittingsfor doors,windows,ventilatorsincl all carriages |
| 81 | chitkis |
| 82 | Handle6\" |
| 83 | Handle 8\" |
| 84 | Haldaraz 8\" |
| 85 | Hinges 2.5\" |
| 86 | Hinges 4\" |
| 87 | P/F of sanitary items incl all carriages |
| 88 | Commode |
| 89 | cistern |
| 90 | wash basin |
| 91 | wall mirror |
| 92 | Angle valves |
| 93 | Bib cocks |
| 94 | Geyser 50 ltrs capacity |
| 95 | Repairing of bleaching,alum motors by way of rewinding of core made of copper metal including replacing of water seal and all sorts of wirings and allcarriages to and fro complete each of 1 HPcapacity |
| 96 | Cement concrete flooring in 1:2:4 mix50 mm thick finished with a floating coaty of neat cementincl cement slurry and curing complete but excl. cost of nosing of steps complete |
| 97 | Supply,providing /Laying /Shrouding of filter mediaof different grades as per sizes Sand (coarse sand in filter bedsincl all carriages)incl all sorts of leads and lifts complete |
| 98 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on new work (Two or more coats) over and incl priming coat with water thinnable cement primer |
| 99 | Finishing walls with water proofing cement paintof required shade on new work (Two or more coats) applied at 3.84 Kgs/Sqm |
| 100 | Painting woodwork with delux multisurface paint of reqd. shadeTwo or more coats applied at 0.90 litres/10 sqm over and under coat of primer applied at 0.75 litres/10 sqm of approved brand and manufacture |
| 101 | carriage of material from source toD/siteby Mechnical Transport including loading unloading and stacking etc. |
| 102 | pipesupto 100mm dia for an avg. lead 20 Kms |
| 103 | Cement/ Steelavg. lead 35 KMs |
| 104 | Stones for a lead of 30 kms |
| 105 | Sand/Aggregates for an avg lead of 30kms |
| 106 | Sand/Aggregates for an avg lead of 35kms |
| 107 | Sand avg. lead for 35 Kms |
| 108 | Stone aggregate 20mm for 35 Kms |
| 109 | Stone solling for 30 Kms |
| 110 | Structural steel for 30 Kms |
| 111 | Bricks for a lead of 60 kms |
| 112 | carriage of material from dumping/ road site tosite of work by Manual Means including loading unloading and stacking etc. for an avg lead of1000 Mtrs |
| 113 | pipes (upto 100mm dia) for a lead of 300 mtrs |
| 114 | Cement/steel for a lead of 500 mtrs |
| 115 | cement /steel for an avg lead of 300 mtrs |
| 116 | Sand for a lead of 300 mtrs |
| 117 | Aggregates for a lead of 300 mtrs 20 mm nominal size |
| 118 | Stone soling for a lead of 300 mtrs |
| 119 | Stone sollingfor a lead of 500 mtrs |
| 120 | Structural Steel for a lead of 300 mtrs |