}

Construction Of Sports Facilities At Ems Stadium Alappuzha Construction Of Sports Facilities At Ems Stadium Alappuzha, alappuzha-Kerala

Kitco Limited-KITCO has published Construction Of Sports Facilities At Ems Stadium Alappuzha Construction Of Sports Facilities At Ems Stadium Alappuzha. Submission Date for this Tender is 04-06-2022. Sports Complex Tenders in alappuzha Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

32323798
Corrigendum : Construction Of Sports Facilities At Ems Stadium Alappuzha Construction Of Sports Facilities At Ems Stadium Alappuzha
Open Tender
Indian
Kerala
alappuzha
04-06-2022

Tender Details

Construction Of Sports Facilities At Ems Stadium Alappuzha Construction Of Sports Facilities At Ems Stadium Alappuzha

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Jun-2022 Corrigendum1 Date 04-06-2022

Key Value

Document Fees
INR 8850 /-
EMD
INR 100000.0 /-
Tender Value
INR 4.01 Crore /-

BOQ Items

Name of Work: Construction of Sports Facilities at EMS Stadium, Alappuzha
Sl. No. Item Description
1Laying and Jointing PVC Pipe. Heading
22.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
32.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
42.10.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:All kinds of soilPipes, cables etc, not exceeding 80 mm dia
52.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
62.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
72.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
82.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
94.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
104.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
11od321729/2020_2021 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete at all levels;Thermo - Mechanically Treated bars of grade Fe-500D or more
12od321730/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account) All work upto plinth level
13od322266/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account)All work above plinth level upto floor V level
14od322265/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note: - Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account).All work upto plinth level
15od251445/2021_2022 : Hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills ,cover slabs and the like, including the cost of fixing in position in line and level etc complete as directed by the Engineer in charge.
165.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
175.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
185.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
19od324012/2020_2021 : Extra for shuttering in circular work - Lintels, beams, plinth beams, girders, bressumers and cantilevers
205.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
215.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
225.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
235.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
246.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.
258.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
268.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete.
279.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured).
289.75.2 : Providing and fixing bright finished door latch with necessary screws etc. complete:250x16x5 mm
299.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
309.97.2 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm
319.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm
329.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper
339.103 : Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete.
349.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness.The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat.Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs.The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
359.122.1 : Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.
3610.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
3710.7 : Providing and fixing ball bearing for rolling shutters.
38od322268/2020_2021 : Supplying and fixing rolling shutters of approved make,made of required size M.S laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets,side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire;springs grade No.2 and M.S top cover of required thickness for rolling shutters including two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, including cost and conveyance of all materials, labour charges,lead,lift etc complete as directed by Engineer in Charge at all levels. 80 X 1.25 mm M.S.Laths with 1.25mm thick top cover
39od322269/2020_2021 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including applying two coats of approved make and colour syntheticenamel paint over two coats of approved makeanticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.;Fixed to openings/ wooden frames with rawl plugs screws etc
40od322329/2020_2021 : Structural steel work welded in single sections,trussess and framed work including cutting, hoisting, fixing in position and applying two coats of Synthetic enamel paint over two coats of anticorrossive Yellow zinc chromate primerincluding cost and conveyance of all materials,labour charges ,lead,lift etc complete as directed by Engineer in Charge at all levels.
4110.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
4211.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer"s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
4311.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick
44od324298/2020_2021 : Providing and layingAntiskid Ceramicfloor tiles 300x300x7 mmof Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand)and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels.
4511.41.1 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm.
4611.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.
4711.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
4812.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
4913.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
5013.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
5113.2.1 : 15 mm cement plaster on the rough side of single or halfbrick wall of mix:1:4 (1 cement :4 fine sand)
52od322271/2020_2021 : 15 mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm including mixing water proofing material in separately).proportion recommended by manufacturer over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer in charge at all levels. (water proofing liquid;will be paid separately);Details of cost for 10 sqm;MATERIAL:;Cement mortar 1:3 ( 1 cement : 3 coarse sand)
5313.8.1 : 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1:3 ( 1 Cement : 3 fine sand)
5413.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
5513.42 : Distempering with 1st quality acrylic distemper (ready mixed) of approvedmanufacturer, of required shade and colour complete, as per manufacturer"sspecification.
5613.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
5713.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
5813.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
5913.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
6013.50.4 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)
6113.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
6213.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
6314.1.1 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
6415.2.2 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
6515.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
6615.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
6715.12.2 : Of area beyond 3 sq. metres
6815.13.2 : Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area beyond 3 sq. metres
6915.17.2 : Dismantling steel work in single sections including dismembering and stacking within 50 metes lead in:Channels, angles, tees and flats
7015.18 : Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
7115.19 : Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge.
7215.23.2 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm
7315.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
7415.58 : Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.
7515.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
7616.70.2 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade
7716.83 : Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
7817.3.1 : Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
7917.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
8018.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes
8118.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes
8218.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes
8318.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes
8418.9.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings.This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge.External work40 mm nominal outer dia pipes
8518.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
8618.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore
8718.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
8818.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
8918.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal
9018.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
9118.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
9218.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore
9318.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
9419.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
9521.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
9621.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
9721.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
9821.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
9921.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
10021.12.2 : Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with S.S. screws etc. complete as per direction of Engineer -in-Charge.Powder coated minimum thickness 50 micron aluminium tubular handle bar
10122.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.
10222.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction ofEngineer-in-Charge.
10322.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structuresuch as raft slab, retaining walls, water storage tank and at the junctions of raftslab with the retaining walls etc.. After cleaning the surface, one coat of requiredprimer for swellable water stop tape shall be applied throughout the length of thejoint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as perspecification and the direction of the engineer-in-charge. The product performanceshall carry guarantee for 10 years against any leakage.
10423.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges
10523.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge
10623.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.
10726.35.2 : Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.)Stirrer mixed SBR Polymer (of approved make) modified Cement slurry madewith Shrinkage Compensating Cement in concrete/RCC work.
10850.2.3.1 : Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete
10950.2.26.1 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
11050.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
11150.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
11250.6.2.1 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
11350.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
11450.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in: CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
11550.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
11650.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
11750.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
11850.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2
11950.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2
12050.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2
12150.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2
12250.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
123od168768/2021_2022 : Supplying and fixing GI threaded rodfor fixing pipes to walls on slotted channels adequately spaced from the walls.The rate is inclusive of cost and conveyance of all materials,labour charges etc and as directed by the Engineer in charge at all levels.
124od323894/2020_2021 : Providing and fixing CP Brass robe hook as per the instructions of the Engineer in;charge. Models Cera F5003108/ Hindware F880004CP or equivalent
125od321740/2020_2021 : Design, supply, laying & jointing in position HDPE pipes, including all fittings and accessories and suitable for the designed working pressures.This includes jointing of pipes & fittings as per the manufacturers specifications ,trenching ,refilling & testing of jointscomplete for extrenal works. The work has to be executed as per approved drawings and or as directed by Engineer - in Charge.40 mm - 10 Kg/cm2
126od321739/2020_2021 : Supplying and Planting Bermuda grass over the red earth and sand bed closely to get a thick grass lawn suitable for ground in rows of 5cm apart in both direction, keep the area moisture by spraying and sprinkling water till the grass gets sufficient deep roots cutting to level the top surface, trimming and dressing etc. complete as directed by the Engineer-in-Charge.
127od168771/2021_2022 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/cm2
128od321741/2020_2021 : Design, supply, laying &; jointing in position HDPE pipes, including all fittings and accessories and suitable for the designed working pressures.This includes jointing of pipes &; fittings as per the manufacturers specifications ,trenching ,refilling &; testing of jointscomplete for external works. The work has to be executed as per approved drawings and or as directed by Engineer - in Charge. ;HDPE pipe 50 mm-10kg/cm ;
129od168773/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings &; specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
130od168767/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kgf/cm2 - Internal work- Exposed on wall
131od168770/2021_2022 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110 mm dia 6 Kgf/cm2
132od168774/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
133od168775/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
134od322274/2020_2021 : Providing and fixing 110mm dia perforated pipe in filter mediacomplete as directed by engineer in charge. The rate including rate andconveyance of materiallabour and fixing charge etc
135od321742/2020_2021 : Design, supply, laying & jointing in position HDPE pipes, including all fittings and accessories and suitable for the designed working pressures.This includes jointing of pipes & fittings as per the manufacturers specifications ,trenching ,refilling & testing of jointscomplete for external works. The work has to be executed as per approved drawings and or as directed by Engineer - in Charge. ;HDPE pipe 63mm-10 kg/cm ;
136od168777/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 kgf/cm2
137od168776/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
138od162623/2021_2022 : Providing and laying non-pressure NP3 class (medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:;150 mm dia R.C.C. pipe
139od321738/2020_2021 : Supplying, stacking and installing root zone, over graded and rolled subgrade include necessary trimming to form the required camber and gradients with layers of course graded medium, fine graded sand to a minimum thickness of 50 mm and providing sand manure mix layer consisting of medium fine sand of U.S.G.A specification, biofibre and biosoil @10 kg/sq.mtr to a minimum thickness of 150 mm. Mixing the above to ensure a homogenous mix and accurate mix of components. The sand manure mix shall be compacted repeatedly by rolling to the grade & camber required and irrigating as required. The cost shall include applying pre mergence herbicide, pre plant fertilizers @10 kg/sq.mto the entire area, Geotextile of minimum 120 gsm, cost of all labour, material ,lead ,lift etc complete as directed by the Engineer in charge.
140od168778/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110mm pipe 6 kgf/cm2
141od321732/2020_2021 : Supplying, laying and jointing perforated HDPE pipe PE 80 of size 110 mm dia 6 kg/cm2 with 5 mm dia perforations, minimum 125 perforations per running metre, in trenches of size 35cm x 45cm at required slope, disposal of excavated earth, as per specifications etc complete including the cost of all materials, labour etc. and as directed by the Engineer-in-charge.Care should be taken while laying so that the perforations will be along the bottom of the pipe. The rate to include cost of all materials, labour charges, lead, lift etc complete.
142od168769/2021_2022 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 160 mm dia 6 Kgf/cm2
143od321743/2020_2021 : Design, supply, laying & jointing in position HDPE pipes, including all fittings and accessories and suitable for the designed working pressures.This includes jointing of pipes & fittings as per the manufacturers specifications ,trenching ,refilling & testing of jointscomplete as per direction of Engineer in charge -for exposed works. The work has to be executed as per approved drawings and or as directed by Engineer - in Charge. ;HDPE pipe 90 mm-10 kg/cm ;
144od162617/2021_2022 : Providing and laying non-pressure NP3 class (medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:;300 mm dia R.C.C. pipe
145od323866/2020_2021 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame;with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour;charges, sundries etc complete as directed by the Engineer in charge at all levels.;110mm dia
146od323869/2020_2021 : Providing and fixing floor trap 110 mm dia (gratings exposed)with cockroach trap (multi trap), S304 grade exposed floor grating with multitrap including cost and conveyance of all materials, labour charges, sundries etc complete;as directed by the directed by the Engineer in Charge at all levels
147od323862/2020_2021 : Supplying and fixing approved quality white vitreous china urinal division plate including cost and conveyance of all material, labour charge, lead, lift, etc. complete as directed by the Engineer-in-Charge. Models- Cera S4090101/ Hindware 61001 or equivalent
148od322272/2020_2021 : Providing and laying PVC membrane waterproofing system in horizontal plane including adjustment layer to take up any surface irregularities of the substrate, in order to avoid any imperfections or foreign particles damaging the waterproof layer. It shalll composed of geotextile, weight of 300 g/m2, laid in dry conditions with edge overlap of 10/15 cm. Synthetic membrane of plasticized PVC, 2mm thick of approved manufactor shall conform to the physical and chemical properties such as: Elongation at break (300%) UNI EN ISO 527-3 or equivalent, Ultimate Tensile Strength ( 16.7 N/mm2;), Puncture resistance ( 1100mm) DIN 16726-5.12 or equivalent, Hydrostatic pressure Waterproof UNI EN 1928 resistance (6 hours at 5 bar) or equivalent. Double seam welding of PVC waterproofing membrane joints pressure tested to 2 bars of 10 minutes the waterproofing project to be divided into sectors if required and it is composed of shaped joints of PVC andit is welded to the existing waterproof liner.;The rate shall be inclusive of providing and laying protection layer of non-woven 300gsm geo-textile membrane over the laid PVC waterproof membrane system, followed by a cement mortar screed of 50mm thick over the top layer of geo-textile membrane to facilitate the placing and tying of reinforcement bars of raft and all pressure release mechanism etc complete as directed by the Engineer-In-Charge.
149od162539/2021_2022 : Providing and fixingconcealed floor trap with cockroach trap (multi trap), SS304 grade;floor grating with cup including cost and conveyance of all materials, labour charges, sundries etc complete;as directed by the directed by the Engineer in Charge at all levels
150od160007/2021_2022 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length;including cost;and conveyance of all materials,labour charges,making good the walls etc complete as;directed by;the Engineer in Charge. 65mm
151od160008/2021_2022 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length;including cost;and conveyance of all materials,labour charges,making good the walls etc complete as;directed by;the Engineer in Charge. 65mm
152od324009/2020_2021 : Supplying and stacking of stone Aggregate (Single size) : 6 mm nominal sizeat site
153od160005/2021_2022 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length;including cost;and conveyance of all materials,labour charges,making good the walls etc complete as;directed by;the Engineer in Charge. 80mm
154od168934/2021_2022 : Supplying and fixingGM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. ;50 mm
155od160002/2021_2022 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length;including cost;and conveyance of all materials,labour charges,making good the walls etc complete as;directed by;the Engineer in Charge. 100mm
156od321762/2020_2021 : Supplying, stacking and laying of20mm downgraded metal (Coarse rubble granite Stone) of approved quality as filter media around the drainage pipes in the sides of trench as per the directions of Engineer-in-charge. Rate inclusive of all materials ,transportation and labour charges complete. The work has to be executed as per detailed specifications , andor as approved by Engineer -in -charge
157od321736/2020_2021 : Supplying ,stacking and laying of compacted fill with 40mm metal (Coarse Rubble Granite Stone);combined with a downgraded stone up to 30mm to form a contour and elevations to the desired level as per;Drawings. Rate inclusive of all materials, transportation and labour charges complete. The work has to be;completed as per detailed specifications and or as approved by Engineer-in-charge
158od321734/2020_2021 : Supplying, stacking and laying of compacted fill with 10mm to downgraded metal (Coarse rubble;granite Stone) combined to form a contour and elevations to the desired level as per Drawings. Rate inclusive;of all materials, transportation and labour charges complete. The work has to be completed as per detailed;specifications and or as approved by Engineer-in-charge
159od321735/2020_2021 : Supplying stacking and laying of compacted fill with 20mm to downgraded metal (Coarse rubble;granite Stone) combined to form a contour and elevations to the desired level as per Drawings. Rate inclusive;of all materials, transportation and labour charges complete. The work has to be completed as per detailed;specifications and or as approved by Engineer-in-charge
160od323867/2020_2021 : Providing and fixing premium quality C.P. brass over head shower with mixer of approved make and model including cost of all materials, labour etc., complete as directed by the Engineer in- Charge at all levels. Models Cera F7020304+F7040104/Hindware F160039+Cera F2006402/Hindware;F280018 or equivalent .
161od323884/2020_2021 : Supplying approved make PVC gully trap of size 160x110mm and CI grating;150mmx150mm size and light duty C.I cover with frames 300mmx300mm size (inside) the weight of cover to;be not less than 4.5kg and frame to be not less than 2.7kg (CI MH cover and frame as per IS:1726) single;sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm, 115 thick brick wall in CM 1:6 on a foundation of PCC 1:4:8. 100mm thick;plastering inside with CM 1:3, 12mm thick with a neat cement flushing coat and conveying to site, cleaning,;installing and testing approved make PVC gully trap with 160mm outlet (fabricated), surrounding with CC;1:1.5:3, 150x150mmm, top with CI grating above the PVC gully trap and light duty CI cover and frame over;the chamber including cost of all materials, etc complete as per approved drawing and as directed by;Engineer-in-Charge.
162od323860/2020_2021 : Providing and fixing star white vitreous china under counter wash basin of approved size & make including one CP brass pillar cock 15 mm NB with aerator including connecting pipes with all fittings 32 mm dia rubber plugs 32 mm dia CP brass waste coupling, 32 mm dia CP brass bottle trap, 15mm angle valve, etc. complete as directed by the Engineer-incharge at all levels.(Models Cera S2030103/;Hindware 10065+ Cera F2006104/Hindware F360001 or equivalent as per the instructions of the engineer in charge)
163od162544/2021_2022 : Providing and fixing water heater (6 litre) with all accessories complete as per the instructions of the Engineer in charge at all levels(Model Jaquar ELM WHT V006 or equivalent)
164od323861/2020_2021 : Providing and fixing white vitreous china flat back urinal with flush valve and C.P.brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: Models Hindware 60002/ Cera S4020112+Cera F9020201/Hindware F850020 or equivalent complete as directed by the Engineer in charge at;all levels
165od323897/2020_2021 : Supplying and fixing D.I. cover with frame for manholes : 600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works includingcost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge
166od323892/2020_2021 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller,;mechanical seal, complete with motor, base plate, foundation bolts, nuts,pressure guage and all;accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all;materials,labour charges;etc complete as directed by the Engineer in charge at all levels;Capacity:8;m3/hr;Head: 15m
167od322270/2020_2021 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight;of the cover to be not less than 210 kg. Complete all works includingcost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge
168od324008/2020_2021 : Supplying and sinking in position RCC open well1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)up to 2.0 m inner diameterand depthmaximum upto 10m in all kinds of soil other than rock to line and levels and plumb by scooping out from inside and below the steining .A layer of 6 mm aggregate,up to thickness of 30 cmshall be filled all around the well to act as a filter media which will be paid seperately under relevant item. The rate shall include the cost and conveyance of all materials ,labour , concrete , reinforcement ,shuttering including removal of obstacles to a suitable locationas directed by the Engineer in Chargeetc. complete as per drawing andas directed by Engineer - in - Charge
169od322301/2020_2021 : Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work;on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling;brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the;brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as;directed by the Engineer-in-charge.
170od321737/2020_2021 : Supply and Installation of a pair of Football goal post of superior quality with nets as per FIFA specifications.
171SPRINKLERS & ACCESSORIES
172Supply,Fixing&CommissoningofPopupsprinklerfull/partcirclehaving radiusofthrow15m-23m&flowof0.09-0.61ltr./sec.atanoperative pressure of 2.5 - 4.5 kg/cm.sq. , The sprinkler is gear driven rotary typewith slipclutchmechanismandheavydutyretractspring.memoryarc ,non strippableand brass reinforced nozzle turret ,left right both side arc adjustment,Memory arc technology,part and fullcircle in same sprinkler .The sprinklershallhavemulti-function,pressure-activatedwipersealforlow pressure opreation a The sprinkler shall have internal Seal - A - Matic device which prevents low head drainage (upto 3.1m) & hence puddling & erosion. Thebody of sprinkler is of non - corrodible, heavy duty, ABS plastic. Work has to be executed as per the approved drawings and/or as per the directions of theEngineer-in-charge.Rate inclusiveofall materials,fittings,labour,transportation complete.
173Supply,Fixing & Commissoning of Sod Cup Kit allows users togrow turf on thecapofthe rotors.Thisallowsforanearlyinvisible installationfor applicationssuchassportsfields.Theruggedconstructionofthe CupKit providesmaximumdurabilitywhilemaintainingmaximum player safety.Integralpullupslot.Easyarcadjustmentafterinstallation through innercup.Drainholestopromotehealthy turfgrowth.Workhastobe executedaspertheapproveddrawingsand/orasperthedirectionsofthe engineer-in-charge. Rateinclusive ofall materials,fittings,labour,transportation complete. engineering plastic.
174Supply,Fixing&Commissoningof 1"PopupConnectingSwingjoint Assembly.ThetubingshallbemadeofUPVC , aworkingpressureof5.5 kg/cm2at43oCandasurgepressureof16.6kg/cm2.Thefittingsshallbe madeofUVresistantthermoplastic.Workhastobeexecutedasperthe approveddrawingsand/orasperthedirectionsoftheengineer-incharge. Rate inclusive of all materials,fittings,labour,transportation complete.
175Supply,Fixing & Commissoning of HDPE service saddle ofvarying size with pressureratingofPN10.Workhastobeexecutedaspertheapproved drawings and/or as per the directions of the engineer-in charge.Rate inclusive of all materials,fittings,labour,transportation complete.
176VALVES & ACCESSORIES
177Supply,Fixing & Commissoning of PVC Ball Valve,security pivot to maintain leverinspace,double watertightjoint,directinjectionstem,non mechanical ,with a base which permits maximum penetration into the valve of size 63mm withpressureratingPN10.Workhastobeexecutedaspertheapproved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials,fittings,labour,transportation complete.
178Supply,Fixing &Commissoningofa double acting1/2" Air release valve, madeofHDPEorhighergradematerial.TheAirreleasevalveshallbe capableofbothreleasingandadmittingairfromandintotheline.The working pressure shall be 5 bar.Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials,fittings,labour,transportation complete.
179Supply,Fixing&Commissoningof12"RectangularValveBox madeof HDPEor higher grade material, with green lid and corrugated structure withuniqueshovel accessslotandboltholeknockout. Workhastobe executedaspertheapproveddrawingsand/orasperthedirectionsofthe engineer-in-charge.Rateinclusiveofall materials,fittings,labour,transportation complete.
180Supply,Fixing&Commissoningof6"Round boxofHDPE orhigher grade material, withgreenlid and corrugated structure with unique shovel accessslotandboltholeknockout.Workhastobeexecutedasperthe approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials,fittings,labour,transportation complete.
181Supply,Fixing & Commissoning of 1.5 inch quickcoupling valve made up of solid brass with locking cover corrosion resistant and stainless steel spring. Workhastobeexecutedaspertheapproveddrawingsand/orasperthe directions of theEngineer-in-charge.Rateinclusive ofall materials,fittings,labour,transportation complete.
182Supply,Fixing&Commissoningofbrasskeythreadsintotopofquick coupling valve to provide water access.Work hasto be executed asper the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials,fittings,labour,transportation complete.
183FILTERATION UNIT
184Supply,Fixing & Commissoning of 3" Disc Filtermade of HDPE having an suitable inletconnections,tocreateahelicaleffectintheincoming water ,spinningparticulateinsuspensionawayfromthefilteringelementandso minimizing cleanings frequency ,3/4" outlet for flushing at bottom of filter & maximumworkingpresure of12 Bars.Workhasto be executedasperthe approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials,fittings,labour,transportation complete.
185PUMPING UNIT
186Supply,Fixing&CommissoningofMonoblocoropenwell submercible pumpset of having dischargeand headof design flow . Duty of Pump :6.50 lps / Each Pump Pressure Head Range= 55 - 60 Mtr No. of Pumps : 1 Working + 0 Standby/.Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials,fittings,labour,transportation complete.
187Supply,Fixing&Commissoningofcontrolpanel suitableforpumpset havingpanelbox madeofCRCAsheetof2mmthicknessandfixed alongwithfollowingaccessoriesDOL starter,start/stoppushbuttons, Ammeter , Single phase preventor, Voltmeter , Indicating lamps , MCB , Dry level guard sensor with control cable, etc. Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.
188Supply,Fixing & Commissoning of Suction ,Delivery & Header Pipesof size suitable for the pump flow ( ASTM sch 40/80 or PVC 10Kg/cm2). Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.
189Supply,Fixing &CommissoningofCI control Valve,ButterflyValvein mainline forbypassandflowdiversionofapprovedquality withpressure rating of PN 10. Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.
190Supply,Fixing & Commissoning of 2" gun metal Non Return Valve PN 10 with all accessories to prevent back flow. Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.
191Supply,Fixing&CommissoningofPVC Pressurereleasevalve2"withall accessories . Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.
192Supply,Fixing&CommissoningofCastIronPaddleWheelWaterMeter Metal Flanged of pressure rating 10 Bar with all accessories . Work has to be executedaspertheapproveddrawingsand/orasperthedirectionsofthe engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.
193Automation Equipment
194Supply,Fixing&Commissoningof14Awgcable withhighmolecular weight polyethelene and applications upto 600volts , temperature upto - 55 to+ 60 deg centigrade ,soft drawnbarecoppermeetingASTM B3, tensile strenth 1400PSI for two way communication betwee nsolenoid valvel and decoders complete .Work has to be executed as per the approved drawings and/orasperthedirectionsoftheengineer-in-charge.Rateinclusiveofall materials of approved make,fittings,labour,transportation complete.
195Supply,Fixing &Commissoningof ASTMStation ModularController UV resistant,wall mount case,with LCD display , non volatile memory for 100years,10KV surge protectionwith removablefront panel and programmableunderbatteryinoffice,totalruntimecalculator,shortdetect errors,onetouchwatering,wityhcontractdefaultprogrames,slowclosing valve removable battery withsensorterminals Workhasto beexecuted as pertheapproveddrawingsand/orasperthedirectionsoftheengineer-in- charge. Rate inclusive ofall materialsofapproved make,fittings,labour,transportation complete.
196Supply,Fixing&Commissoningof3" Solenoidglobe Valvesascentral shut off valve with fabric reinforced diaphramand rugged PVC construction , compatibleandslowclosingtopreventwaterhammer,pressureratingupto 0,7 to 10 bar and maximum flow of 10 to 100 m3/h,max water temp. upto 60°C with24 VAC - 50 Hz,coil resistance 30ohm withprovision to attach PressureRegulatingModule(Dial). Workhastobeexecutedasperthe approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.
197Supply,Fixing&Commissoningof2"Solenoidglobe Valveswithfabric reinforceddiaphram andruggedPVCconstruction ,compatibleandslow closing to prevent water hammer,pressure rating upto 10.4bar and maximum flowof150GPM,maxwatertemp.upto42degreecentigrade,with24AC solenoid,current rating 0.41A @60Hz,coil resistance 30 ohm withprovision to attachPressure Regulating Module (Dial). Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.
198Supply,Fixing &CommissoningofPressureRegulatingModule(Dial)to Maintainconstantoutlet pressurebetween 1.04 to6.9 bar. Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.
199Supply,Fixing &Commissoningof directbury-onwire connectorwith strainrelief,UL486D certified ,withwaterproofsiliconsealant,fits wirefrom22gato6gaasperspecificationscomplete.Workhastobe executedaspertheapproveddrawingsand/orasperthedirectionsofthe engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.
200Supply,Fixing & Commissoningof moisture sensing device ,to measure soil temp,EC ,Moisture levelcomplete to convert as smart controller,with corrossion resistant sensorand setting thershhold moisture level . Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.
201Supply,Fixing&Commissoningof ASTMautomaticrainshutoffdevice ,latching hinge with multiple rainfall settings 5mm to 20mm UL CUL listed andCEapprovedcomplete.Workhastobe executedaspertheapproved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.
202Supply,Fixing & Commissoning of Pump relay24 ACPLA relay,stabiliser 300watts. Work has to be executed as per the approved drawings and/or as per thedirectionsoftheengineer-in-charge.Rateinclusiveofallmaterialsof approved make,fittings,labour,transportation complete.
203od219505/2021_2022 : Supply, Installation,Testing and Commissioning of 125A FP, On load change over switch AC 23A duty, 1NO+1NC auxillary contact in sheet steel enclosure complete with handle assembly having door interlock , pad locking arrangement, adapter boxand all other accessories as required complete.
204od220583/2021_2022 : Supply, installation, testing and commissioning of KSEB metering panel, suitable for accomodating 3 Phase CT operated TOD meter and consisting of 3 nos. of 125 A cutout with HRC fuse( or as per KSEB) , neutral link, 125A ,25 kA,FP MCCB with earth leakage protection, in separate chamber,inter connections etc. as required, and necessary supports to be fabricated out of 14 SWG CRCA sheet with locable door with sealing facility having glass window for energymeter, sealing facility for KSEB, top canopy and necessary overhang, undergone seven tank process , powder coated finish and all mounting accessories. The panel shall be with all accessories as per drawing & specification.
205od220602/2021_2022 : MSB Supply, installation, testing and commissioning of LT Switch Board (Main Panel), cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, wall / floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc. The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be of Form 4 Construction.Instruments RYB Indicating lamps LED type , 4A SP MCB, (0-500)V Class 1 with 90 deg defl. Scale-,(0-125)A Class 1 with 90 deg defl. Scale, Ammeters asPer sld, switch ,Voltmeter selector switch , 125/5 A 5 VA Class 1 CTs , Digitalmultimeter to read V,A.Hz,PF,kWH , surge protection device (type1) etc. as per SLDIncomer- 125A,25 KA, FP Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25KA) -1 Nos200A TPN busbar chamber with Aluminium busbarOut goings - 100A TP +NL Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25KA) -2 Nos, 63A TP +NL Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25KA) -2 Nos25A TP +NL Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25KA) -1 Nos, 25A DP Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25KA) -1 NoThe panel shall be Top Entry/Exit and suitable for termination of cable system as per SLD and technical specification
206od221165/2021_2022 : ODPSupply, Installation, Testing and Commissioning of Outdoor Lighting Panel (ODP) cubicle type, totally enclosed, IP 65, pedestal mounted, free standing with top canopy, dust and vermin proof, water proof suitable for operation on 3 phase, 415 V, 50Hz AC supply with provision for fixing incoming & outgoing switches fabricated using 2mm thick CRCA sheet, powder coated, including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc., The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) including following switchgears accessories for the LT Panel. The Panel shall be of form 4 construction INCOMER 100 A, FP, 25kA, MCCB with adjustable thermal magnetic release with OL & SC protection - 1 No BUSBARS 100 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy - 1 Set INSTRUMENTS Surge protection device -Type1+2 (0-500)V voltmeter Acc.class 1 with VSS- 1 No (0-100)A ammeter Acc. class 1 with 90 deg defl. scale - 3Nos 4A, C curve SP MCB - 3 Nos. RYB indication lamp, LED type - 1 Set OUTGOINGS 25 A, FP RCCB (100mA)-11 Nos 25 A C Curve FP MCB-11 Nos. The rate for the foundation shall be measured with civil works
207CABLES AND ACCESSORIES
2087.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
2097.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
2107.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
2117.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
2127.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
2139.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
21414.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia
2154.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness
216od216458/2021_2022 : Supplying and making end termination with brass compression gland and copper lugs for following 2C 4 Sq.mm Cu size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required
217od216460/2021_2022 : Supplying and making end termination with brass compression gland and copper lugs for following 4C 4 Sq.mm Cu size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required
218od216461/2021_2022 : Supply of 4C 4 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
219od216462/2021_2022 : Supply of 2C 4 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
220od216464/2021_2022 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed,armoured Aluminiumconductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 35sqmm
2217.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
2227.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm
2237.2.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
2247.2.2 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
2257.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm
2267.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
2277.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
2287.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
2297.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
2307.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
231od217778/2021_2022 : Supply of following 3.5C 70 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
232od217779/2021_2022 : Supply of following 3.5C 120 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
233od217780/2021_2022 : Supplying and making end termination with brass doublr compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C 2.5 Sq.mm Cu<br
234od217781/2021_2022 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 2.5 Sq.mm Cu
235od217799/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 10 Sq.mm Al
2369.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
2379.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
2389.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
239od217983/2021_2022 : Supplying and making end termination with brass compression gland and copper lugs for following 3C 2.5 Sq.mm Cu size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required
240od217984/2021_2022 : Supply of 3C 2.5 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
241od220670/2021_2022 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required 300 MM WIDTH X 50MM DEPTH X 2 MM THICK
242od220671/2021_2022 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required 150 MM WIDTH X 50MM DEPTH X 2 MM THICK
243MCB AND DISTRIBUTION BOARDS
2442.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
2452.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2462.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2472.11 : Supplying and fixing single pole blanking plate inthe existing MCB DB complete etc. as required.
248od216456/2021_2022 : Supply and fixing of following 4 pole 63amps. (415 Volts),100mA sensitivity rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required
249od216463/2021_2022 : Supply and fixing of following 2 pole 25amps. (415 Volts),100mA sensitivity rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required
250od216465/2021_2022 : Supply and fixing outdoor type START/STOP (2way) push button station (IP65) includingall the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalentapproved make)
251od216470/2021_2022 : Supply and fixing of following 4 pole 25amps. (415 Volts),30mA sensitivity rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required
2522.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
25390.11.1.12 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
25490.11.1.15 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) -double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
255od217857/2021_2022 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for double door vertical DB with modular incomer
256od217858/2021_2022 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 12 way double door horizontal type SPN DB
257od217859/2021_2022 : Supply and fixingof following rating, 10 KA, Miniature Circuit Breakersas required. 40 A to 63A TP MCB, C-CURVE
25890.14.28.2 : S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor
259LIGHT FIXTURES AND FANS
260od216448/2021_2022 : Supply of 10w LED Bulk head fitting with die cast aluminium housing, PC diffuser and IP65 Protection suitable for wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire and making good the surface as required.(make: Wipro LW07 or equivalent wipro make)
261od216449/2021_2022 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Crompton Brisk Air or equivalant approved make)
262od216454/2021_2022 : Supply of indoor decorative surface mounted LED Batten with High Efficiency Polycarbonate housing and Polycarbonate Diffuser ,along with driver, max system wattage of 20 Watts,lumen output of lamp greater than 2000, power factor > 0.9,rated life of L70 @ 25,000 hours, system efficacy greater than 80lumen/watt and including all the necessary accessories as required complete(Make: Wipro Trim LED Batten 20W LL20-221-XXX-65NE3 or equivalent one)
263od216455/2021_2022 : Supply of indoor decorative surface mounted LED Batten with Poly Carbonate Body and PolyCarbonate Diffuser,along with driver,max system wattage of 10 Watts,lumen output of lamp greater than 900, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 90 lumen/watt and including all the necessary accessories as required complete(Make :Wipro Trim LED 10W LL20-111-XXX-65NE3 or equivalent approved make)
264od216457/2021_2022 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Rate shall inclusive of supply and installation of remote/electronic regulator
2651.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
2661.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.
2671.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
268od217864/2021_2022 : Supply of IP66 LED Street Lighting luminaire ,pressure die cast aluminium housing body with optimal heat sink, with system wattage of maximum 30W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens greater than 3000 and system efficiency greater than or equal to 90%.The Light fitting shall be with all required accessories suitable for mounting on the pole arm.The luminaire should have Inbuilt surge protection of4KV (L-N ,L-E & N-E)and should be equipped with external surge protection device (SPD) to withstand 5KV5AMake:- Cat No: Wipro LR02-331-XXX-57-XX or equivalent approved make
269od217865/2021_2022 : Supply Installation Testing and Commissioning of 1.5 meter overhang Single arm bracket (50mm OD) suitable for mounting1 no'sstreet Light fixtures. Thebracket assembly shall be secured on to the A type pole with 2 annular rings with allen grub screws.The total street lighting bracket shall be hot dip galvanised which includes the supply, drawing and termination of 3c x 2.5 sqm flexible CU wire from control box to the light fixture and all other necessary accessories as required to complete.
270od217866/2021_2022 : Supply of LED surface mounted down light made of die cast aluminium, along with driver,system wattage of maximum 12 Watts, with lumen output of luminaire greater than or equal to 1200 lumens, power factor > 0.95, THD<10%, rated life of L70 @ 50,000 hours, system efficacy greater than or equal to 100 lumen/watt and including all necessary accessories as required complete.Make:- Cat No: - Crompton -LCDSPLN-R-12-CDL or equivalent approved make
271EARTHING AND SAFETY EQUIPMENTS
272od216450/2021_2022 : Supply and fixing single line diagram, schematic diagrams etc. of A0 size on suitable Aluminium sheet including lamination etc. as required complete on wall.
273od216452/2021_2022 : Supply and fixing of First aid box
27490.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
2755.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
2765.9 : Supplying and laying 25 mm X 5 mm G.Istrip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
2775.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
278od220672/2021_2022 : Supplying and laying 3.15mm Cu (10 SWG) Copper wire at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of nut bolt & spring washer spaced at 50mm)
279od256989/2021_2022 : Supplying and laying 8 swg GI wire at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
280M.S ITEMS
281od216445/2021_2022 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required
282WIRING AND ACCESSORIES
2831.17.1 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
2841.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
2851.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
2861.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
2871.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
2881.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
2891.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
2901.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
2911.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
2921.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
2931.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
2941.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
2951.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
2961.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
297od216466/2021_2022 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in existing PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
298od216468/2021_2022 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
299od216471/2021_2022 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
300od216474/2021_2022 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
3011.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet
302EXTERNAL LIGHTING
30390.15.3.3 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed asperIS 875 Part III single arm bracket 0.5mt includingconnector foundation bolt 4 nos fixed in existing RCC foundation andjunction box etc. complete 6 Meters
304od219359/2021_2022 : Supply, installation testing and commissioning of ofLED bollards with not less than 500 mm in height. The LED lamp shall have a maximum system wattage of 10W.The body shall be powder coated extruded aluminium.Luminaries provided with LED driver suitable for operation on 240V, 50Hz single phase ac supply.The fixture shall have IP65 class protection & shall be provided with all accessories and civil foundations.( Wipro LB12-131-XXX-65-08 or equivalent approved make)
305od219400/2021_2022 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 155 mm bottom diameter thickness 3mm base plate dimensions of 250x250x16 mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos fixed in existing RCC foundation adn junction box etc, complete 12 Meters
306od219455/2021_2022 : Supply, of LED Flood light luminaire of IP66 protected, pressure die cast aluminium housing body with toughened glass and power ledwith 10 degree beam angle , optimal heat sink and , with maximum system wattage 500 W with rated life of L70 @ 50,000 hours, with10kV surge protection CRI greater than or equal to 70 & with system lumens not less than 57500 and system efficiency greater than or equal to 115 lumen/watt.The Light fitting shall be with all required accessories suitable for mounting in (48-60)mm. The luminaire should meet all the technical specifications as mentioned. (Make: Crompton CFS-506-500-57-10D-HL2-GL-NBR or equivalent approved make)Net
307od219456/2021_2022 : Supply Conveyance, installation, testing and commissioning of 45W LED street light output greater than 100lumen/W 4000-6000 K, IP 66 with power factor greater than 0.9 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.9, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)Make: Crompton LSTS-45-CDL-M / wipro LR02-501-XXX-57-G1 or equivalent approved make.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail