Construction Of Stadium At Chelad Construction Of Stadium At Chelad Kothamangalam
Tender Value
8.70 Crore
Estimated cost
Bid Submission
31 May 2022
0 days left
EMD
2 Lakhs
Bank guarantee accepted
Document Fee
11700
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Stadium At Chelad Construction Of Stadium At Chelad Kothamangalam
BOQ
| Sl. No. | Item Description |
| 1 | Laying and Jointing PVC Pipe. Heading |
| 2 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 3 | 2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock |
| 4 | 2.7.3 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited) |
| 5 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 6 | od135360/2021_2022 : Extra for compaction of earth work under optimum moisture conditions to give at least 95% of the maximum dry density in layers not exceeding 20cm ( proctor density) |
| 7 | 2.10.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:All kinds of soil Pipes, cables etc, not exceeding 80 mm dia |
| 8 | 2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 9 | 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 10 | 2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil |
| 11 | 2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 12 | 4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 13 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 14 | 4.2.3 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 15 | 4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer\"s specification . |
| 16 | od135592/2021_2022 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note: - Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account).;All work upto plinth level; |
| 17 | od135365/2021_2022 : Providing ,hoisting and fixing upto floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete but excluding the cost of reinforcement with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262. |
| 18 | od135361/2021_2022 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account) All work upto plinth level |
| 19 | od135369/2021_2022 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account)All work above plinth level upto floor V level |
| 20 | od135362/2021_2022 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete at all levels;Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 21 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 22 | 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 23 | 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 24 | 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 25 | 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 26 | 5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) |
| 27 | 5.9.15 : Centering and shuttering including strutting, etc. and removal of form for:Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 28 | 5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 29 | 5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges |
| 30 | 5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size) |
| 31 | 5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. |
| 32 | 6.2.2 : Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand) |
| 33 | 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 34 | 8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm |
| 35 | 8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc.including moulding, rubbing and polishing of cut edges etc. complete. |
| 36 | 8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete. |
| 37 | 9.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 38 | 9.77 : Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete |
| 39 | 9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 40 | 9.97.2 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm |
| 41 | 9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm |
| 42 | 9.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper |
| 43 | 9.103 : Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete. |
| 44 | 9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness.The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat.Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs.The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 45 | 9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge. |
| 46 | 9.126.1 : Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebates to be measured).Panelling for panelled and glazed shutters 25 mm to 40 mm thick.Marine plywood conformingto IS : 710 |
| 47 | 9.127.2 : Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.0 mm thick |
| 48 | od135372/2021_2022 : Structural steel work welded in single sections,trussess and framed work including cutting, hoisting, fixing in position and applying two coats of Synthetic enamel paint over two coats of anticorrossive Yellow zinc chromate primerincluding cost and conveyance of all materials,labour charges ,lead,lift etc complete as directed by Engineer in Charge at all levels. |
| 49 | od135370/2021_2022 : Steel work in built up tubular sections YST 310 grade as per IS: 4923 including cutting, bending, hoisting, fixing in position, welded and bolted including special shaped washers etc. complete with electric resistance or induction butt welded tubes including painting with two coats of approved make and colour syntheticenamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, closing all the open ends properly with same material cost and conveyance of all materials, labour, etc., complete as directed by the Engineer-in-Charge at all levels. |
| 50 | od135371/2021_2022 : :Steel work welded in built up sections/framed work including cutting hoisting, fixing in;position and applying two coats of approved make and colour synthetic enamel paint over two coats of;approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all;materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.;In gratings,;frames, guard bar, ladders, railings, brackets, gates & similar works.; |
| 51 | od135556/2021_2022 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including applying two coats of approved make and colour syntheticenamel paint over two coats of approved makeanticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.;Fixed to openings/ wooden frames with rawl plugs screws etc |
| 52 | od135557/2021_2022 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including painting with two coats of approved make and colour syntheticenamel paint over two coats of approved make anticorrossive yellow zinc chromate primer.;M.S. tube |
| 53 | od135595/2021_2022 : Supplying and fixing rolling shutters of approved make,made of required size M.S laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets,side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire;springs grade No.2 and M.S top cover of required thickness for rolling shutters including two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, including cost and conveyance of all materials, labour charges,lead,lift etc complete as directed by Engineer in Charge at all levels. 80 X 1.25 mm M.S.Laths with 1.25mm thick top cover |
| 54 | 10.7 : Providing and fixing ball bearing for rolling shutters. |
| 55 | 10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 56 | 10.27.2 : Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10 x 80 mm |
| 57 | 11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer\"s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete |
| 58 | 11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement . 18 mm thick |
| 59 | od135558/2021_2022 : Providing and layingAntiskid Ceramicfloor tiles 300x300x7 mmof Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand)and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels. |
| 60 | 11.26.1 : Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick |
| 61 | 11.27 : Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 62 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 63 | 13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). |
| 64 | 13.8.1 : 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1:3 ( 1 Cement : 3 fine sand) |
| 65 | 13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 66 | od135368/2021_2022 : 15mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm including mixing water proofing material inseparately).proportion recommended by manufacturer over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer in charge at all levels. (water proofing liquid will be paid separately) |
| 67 | 13.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 68 | 13.42 : Distempering with 1st quality acrylic distemper (ready mixed) of approvedmanufacturer, of required shade and colour complete, as per manufacturer\"s specification. |
| 69 | 13.43.1 : Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer |
| 70 | 13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 71 | 13.45.1 : Finishing walls with textured exterior paint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm |
| 72 | 13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 73 | 13.50.4 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) |
| 74 | 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 75 | 13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 76 | 13.62.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to givean even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . |
| 77 | 15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved |
| 78 | 16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ).( Precast C.C. kerb stone shall be approved by Engineer-in-Charge) |
| 79 | 16.70.2 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade |
| 80 | 16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 |
| 81 | 16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge. |
| 82 | 16.91.1 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design& pattern. |
| 83 | 16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 84 | 19.19.3.1 : Circular shape 560 mm internal diameter |
| 85 | 21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 86 | 21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 87 | 21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness |
| 88 | od135555/2021_2022 : Providing and fixing glazing with 12mm toughened glass in existing aluminium frame work with EPDM;rubber / neoprene gasket.The joints between glass panels and gaps at the perimeter of the assembly to;be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof;etc. complete as per the architectural drawings and the directions of Engineer-in-charge |
| 89 | 21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness |
| 90 | 21.15.1 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc.complete.Anodized (AC 15 ) aluminium |
| 91 | 22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 92 | 22.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. |
| 93 | 22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of requiredprimer for swellable water stop tape shall be applied throughout the length of thejoint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. |
| 94 | 23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charge. |
| 95 | 23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge |
| 96 | 23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 97 | 50.2.3.1 : Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete |
| 98 | 50.2.25.1 : Filling with contractor\"s own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge. |
| 99 | 50.2.26.1 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge. |
| 100 | 50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete |
| 101 | od135554/2021_2022 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of Half thick solid block masonry. |
| 102 | 50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 103 | 50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in: CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete |
| 104 | 50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 |
| 105 | od135508/2021_2022 : Supplying, laying and jointing perforated HDPE pipe PE 80 of size 110 mm dia 10 kg/cm2 with 5 mm dia perforations, minimum 125 perforations per running metre, in trenches of size 35cm x 45cm at required slope, disposal of excavated earth, as per specifications etc complete including the cost of all materials, labour etc. and as directed by the Engineer-in-charge.Care should be taken while laying so that the perforations will be along the bottom of the pipe. The rate to include cost of all materials, labour charges, lead, lift etc complete. |
| 106 | od135509/2021_2022 : Providing and laying of20mm downgraded metal (Coarse rubble granite Stone) of approved quality as filter media around the drainage pipes in the sides of trench as per the directions of Engineer-in-charge. Rate inclusive of all materials,transportation and labour charges complete. |
| 107 | od135510/2021_2022 : Providing and laying of compacted fill with 10mm to downgraded metal (Coarse rubblegranite Stone) combined to form a contour and elevations to the desired level as per Drawings.Rate inclusiveof all materials,transportation and labour charges complete.The work has to be completed as per detailedspecifications and or as approved by Engineer-in-charge |
| 108 | od135511/2021_2022 : Providing and laying of compacted fill with 20mm to downgraded metal (Coarse rubblegranite Stone) combined to form a contour and elevations to the desired level as per Drawings.Rate inclusiveof all materials,transportation and labour charges complete.The work has to be completed as per detailedspecifications and or as approved by Engineer-in-charge |
| 109 | od135512/2021_2022 : Providing and laying of compacted fill with 40mm metal (Coarse Rubble Granite Stone)combined with a downgraded stone up to 30mm to form a contour and elevations to the desired level as perDrawings.Rate inclusive of all materials,transportation and labour charges complete.The work has to becompleted as per detailed specifications and or as approved by Engineer-in-charge. |
| 110 | od135513/2021_2022 : Supply and Installation of a pair of Football goal post of superior quality with nets as per FIFA specifications. |
| 111 | od135514/2021_2022 : Providing and installing root zone, over graded and rolled subgrade include necessary trimming to form the required camber and gradients with layers of course graded medium, fine graded sand to a minimum thickness of 50 mm and providing sand manure mix layer consisting of medium fine sand of U.S.G.A specification, biofibre and biosoil @10 kg/sq.mtr to a minimum thickness of 150 mm. Mixing the above to ensure a homogenous mix and accurate mix of components. The sand manure mix shall be compacted repeatedly by rolling to the grade & camber required and irrigating as required. The cost shall include applying pre mergence herbicide, pre plant fertilizers @10 kg/sq.mto the entire area, Geotextile of minimum 120 gsm, cost of all labour, material ,lead ,lift etc complete as directed by the Engineer in charge. |
| 112 | od135515/2021_2022 : Supplying and Planting grass over the red earth and sand bed closely to get a thick grass lawn suitable for ground in rows of 5cm apart in both direction, keep the area moisture by spraying and sprinkling water till the grass gets sufficient deep roots cutting to level the top surface, trimming and dressing etc. complete as directed by the Engineer-in-Charge. Bermuda Grass; |
| 113 | od135516/2021_2022 : Design, supply, laying & jointing in position HDPE pipes, including all fittings and accessories and suitable for the designed working pressures.This includes jointing of pipes & fittings as per the manufacturers specifications ,trenching ,refilling & testing of jointscomplete for extrenal works. The work has to be executed as per approved drawings and or as directed by Engineer - in Charge.40 mm - Kg/cm2 |
| 114 | od135517/2021_2022 : Design, supply, laying & jointing in position HDPE pipes, including all fittings and accessories and suitable for the designed working pressures.This includes jointing of pipes & fittings as per the manufacturers specifications ,trenching ,refilling & testing of jointscomplete for external works. The work has to be executed as per approved drawings and or as directed by Engineer - in Charge. ;HDPE pipe 50 mm-6 kg/cm2; |
| 115 | od135518/2021_2022 : Design, supply, laying & jointing in position HDPE pipes, including all fittings and accessories and suitable for the designed working pressures.This includes jointing of pipes & fittings as per the manufacturers specifications ,trenching ,refilling & testing of jointscomplete for external works. The work has to be executed as per approved drawings and or as directed by Engineer - in Charge. ;HDPE pipe 63mm-6 kg/cm2; |
| 116 | od135519/2021_2022 : Design, supply, laying & jointing in position HDPE pipes, including all fittings and accessories and suitable for the designed working pressures.This includes jointing of pipes & fittings as per the manufacturers specifications ,trenching ,refilling & testing of jointscomplete as per direction of Engineer in charge -for exposed works. The work has to be executed as per approved drawings and or as directed by Engineer - in Charge. ;HDPE pipe 90 mm-6 kg/cm2; |
| 117 | od135560/2021_2022 : Extra for providingarchitechtural grooves 25 mm x 6mm in plastering @125mm c/c, including cost and conveyance of all material, labour, scaffolding etc. complete as directed by the Engineer in charge. |
| 118 | od135561/2021_2022 : Providing and applying Antitermite treatment by injecting chemical emulsion Imidacloprid emulsiable concentrate 0.075% for pre-constructional treatment and creating a chemical barrier as per IS 6313 (Part II) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building, etc. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge. (Plinth area only to be measured forthe payment ) |
| 119 | od135597/2021_2022 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight;of the cover to be not less than 210 kg. Complete all works includingcost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge |
| 120 | od135599/2021_2022 : Providing and laying PVC membrane waterproofing system in horizontal plane including adjustment layer to take up any surface irregularities of the substrate, in order to avoid any imperfections or foreign particles damaging the waterproof layer. It shalll composed of geotextile, weight of 300 g/m2, laid in dry conditions with edge overlap of 10/15 cm. Synthetic membrane of plasticized PVC, 2mm thick of approved manufactor shall conform to the physical and chemical properties such as: Elongation at break (300%) UNI EN ISO 527-3 or equivalent, Ultimate Tensile Strength ( 16.7 N/mm2;), Puncture resistance ( 1100mm) DIN 16726-5.12 or equivalent, Hydrostatic pressure Waterproof UNI EN 1928 resistance (6 hours at 5 bar) or equivalent. Double seam welding of PVC waterproofing membrane joints pressure tested to 2 bars of 10 minutes the waterproofing project to be divided into sectors if required and it is composed of shaped joints of PVC andit is welded to the existing waterproof liner.;The rate shall be inclusive of providing and laying protection layer of non-woven 300gsm geo-textile membrane over the laid PVC waterproof membrane system, followed by a cement mortar screed of 50mm thick over the top layer of geo-textile membrane to facilitate the placing and tying of reinforcement bars of raft and all pressure release mechanism etc complete as directed by the Engineer-In-Charge. |
| 121 | od135601/2021_2022 : Providing and fixing 110mm dia perforated pipe in filter mediacomplete as directed by engineer in charge. The rate including rate andconveyance of materiallabour and fixing charge etc |
| 122 | od135647/2021_2022 : Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work;on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling;brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the;brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge. |
| 123 | od135648/2021_2022 : Supplying and sinking in position RCC open well 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) up to 2.0 m inner diameter and depth maximum upto 10m in all kinds of soil other than rock to line and levels and plumb by scooping out from inside and below the steining .A layer of 6 mm aggregate,up to thickness of 30 cm shall be filled all around the well to act as a filter media which will be paid seperately under relevant item. The rate shall include the cost and conveyance of all materials ,labour , concrete , reinforcement ,shuttering including removal of obstacles to a suitable location as directed by the Engineer in Charge etc. complete as per drawing and as directed by Engineer - in - Charge |
| 124 | od135649/2021_2022 : Supplying and stacking of stone Aggregate (Single size) : 6 mm nominal sizeat site |
| 125 | od135652/2021_2022 : Extra for shuttering in circular work - Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 126 | 17.3.1 : Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 127 | od130307/2021_2022 : Providing and fixing of star white vitreous china under counter wash basin of approved make and size including one CP brass pillar cock 15 mm NB including connecting pipes with all fittings 32 mm dia rubber plug,s 32mm dia CP brass waste coupling, 32 mm dia CP brass bottle trap,CP brass 15mm angle valve,complete including CI/MS brackets duly painted, nuts, washers, etc. complete,including cost and conveyance of all materials labour charges ,lead, lift necessary wall cutting / chasing and making good the walls,floors,slab,testing and commissioning to the satisfaction of Engineer in charge at all levels.(Model no:Hindware 10049/Cera S2030104 or equivalent+ Jaquar catalogue no: OPP-15001PM or Kohler catalogue no:16312IN-4-CP or equivalent,+Jaquar catalogue no: ALD-705L130 or Kohler catalogue no: 7314-IN-CP or equivalent+Jaquar catalogue no: ALD 769 L 300 or equivalent+Jaquar catalogue no: OPP-15053PM or Kohler catalogue no:80154IN-4-CP or equivalent and the equivalent shall be approved by the Engineer in charge) |
| 128 | od130308/2021_2022 : Providing ; fixing ofstar white vitreous china flat back urinal with urinal flush valve, of approved size and make with all accessories to provide satisfactory functioning including necessary wall cutting / chasing and making good, as required for urinal flushing etc complete, testing and commissioning as per direction of Engineer-In charge at all levels.(Models: Hindware catalogue no: 96008 or Cera catalogue no: S4020107 or equivalent,Jaquar PRS-077 or equivalent and the equivalent shall be approved by the Engineer in charge) |
| 129 | od130309/2021_2022 : Supplying and fixing of star white vitreous china urinal division plate of approved quality and make including cost and conveyance of all material, labour charge, lead, lift,screws,accessories etc. complete as directed by the Engineer-in-Charge.(Models: Hindware catalogue no: 61001 or equivalent and the equivalent shall be approved by the Engineer in charge) |
| 130 | 50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 131 | od130310/2021_2022 : Providing and fixing sanitary fixtures for handicaped toilet including one wash ;,one pair mounting brackets,one number pillar cock ; all other related fittings like bottle;trap;,anglecock,waste coupling, etc,one number EWC ; Cistern complete with fittings ; seat cover, one;no.;hinged rail76cm ; 4nos. of grab rails 60cm etc designed for people with special needs comes with as;per;manufacturesspecification including cutting and making good the walls and floors wherever required;as per;drawing andas directed by Engineer in charge. (Model no: Hindware (70002 or Cera Cruse;set,Jaquar catalogue no: OPP-15001PM or Kohler catalogue no:16312IN-4-CP or equivalent+Jaquar catalogue no: ALD-705L130 or equivalent +Jaquar catalogue no: ALD 769 L 300 or Kohler catalogue no: 7314 IN-CP or equivalent+Jaquar catalogue no: OPP-15053PM or Kohler catalogue no: 80154IN-CP or equivalent and the equivalent shall be approved by the Engineer in charge) |
| 132 | od130311/2021_2022 : Providing and fixing frameless mirror, with all four edges machine polished and back side protected with safety film and 4 mm thick Plywood backing and fixed on walls with mirror screws. The rate includes lifting, cutting etc. as per design and drawing. |
| 133 | 18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 134 | 50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 135 | od130312/2021_2022 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame ; Round Frame with Flat Round Cover with Rubber Seal ; SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels 75mm dia |
| 136 | od130313/2021_2022 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame ; Round Frame with Flat Round Cover with Rubber Seal ; SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels 110mm dia |
| 137 | od130314/2021_2022 : Providing and fixing premium quality C.P. brass wall shower mixer with provision for;overhead shower with 115mm long bend pipe on upper side,connecting legs and wall flanges of approved;make and model including cost of all materials, labour etc., complete as directed by the Engineer-in-Charge;at all levels. (Models: Jaquar catalogue no: FUS 29273UPR or equivalent and the equivalent shall be approved by the Engineer in charge) |
| 138 | od130315/2021_2022 : Providing and fixing C.P. brass concealed stop cock (control valve) 20 mm dia of standard design and of approved make conforming to IS:8931 etc. including cost and conveyance of all materials,labour charges, lead,lift, necessary wall cutting / chasing and making good the walls,floor,slab etc complete, testing and commissioning to the satisfaction of Engineer in charge at all levels.(Model-Jaquar cat no: OPP- 15083KPM+ALD-089 or equivalent and the equivalent shall be approved by the Engineer in charge) |
| 139 | 50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 140 | od130316/2021_2022 : Providing and fixing floor trap with cockroach trap (multi trap), SS304 grade floor grating with cup inclu ding cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer-in-Charge at all levels |
| 141 | 50.18.9.18.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing.This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall |
| 142 | 50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl |
| 143 | 50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 144 | 50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2 |
| 145 | 50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 |
| 146 | 18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes |
| 147 | od130318/2021_2022 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot ; cold water supply, including all CPVC plain ; brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes ; fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall;80 mm nominal dia pipes |
| 148 | od130319/2021_2022 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot ; cold water supply, including all CPVC plain ; brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes ; fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall ;65 mm nominal dia pipes |
| 149 | 18.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings.This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge.External work50 mm nominal outer dia pipes |
| 150 | 18.9.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings.This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge.External work40 mm nominal outer dia pipes |
| 151 | 50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2 |
| 152 | 50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2 |
| 153 | 50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 154 | 18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes |
| 155 | 18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes |
| 156 | 18.8.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes |
| 157 | od130320/2021_2022 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot ; cold water supply, including all CPVC plain ; brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes; fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.40 mm nominal outer dia pipes |
| 158 | od130321/2021_2022 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.: 300 mm dia RCC pipes. |
| 159 | od130322/2021_2022 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including;collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2;(1 cement : 2 fine sand) including testing of joints etc. complete.150 mm dia RCC pipes. |
| 160 | 18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 161 | 18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore |
| 162 | 18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore |
| 163 | 18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 164 | 18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore |
| 165 | 18.19.2.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):32 mm nominal bore Horizontal |
| 166 | 18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal bore Horizontal |
| 167 | od130323/2021_2022 : Supplying and fixing foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. 50 mm dia |
| 168 | od130324/2021_2022 : Supplying and fixing foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. 40 mm |
| 169 | 19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 170 | od130325/2021_2022 : Providing and fixing C.I. grating 150x150 mm as directed by the Engineer-in-charge |
| 171 | od130326/2021_2022 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 50mm Y type strainer |
| 172 | od130327/2021_2022 : Providing and fixing C.I. basket typedirt box strainer 50mm dia for bulk type water meter with nuts, bolts, rubberetc. complete conforming to IS : 2373 : including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge |
| 173 | od130328/2021_2022 : Providing and fixing enclosed type water meter (bulk type) 50mm diaconforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber etc. (The tail pieces if required will be paid separately) including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge |
| 174 | 18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal bore Horizontal |
| 175 | od130329/2021_2022 : Providing and fixing under counter mounting pressmatic/ automatic liquid soap;dispenser of approved make including cost and conveyance of all materials labour charges ,lead, lift, cuttingand making good the walls, floors and slab wherever required etc complete, testing and commissioning tothe satisfaction of Engineer in Charge as directed by the Engineer in Charge at all levels |
| 176 | 50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 |
| 177 | 18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore |
| 178 | od130330/2021_2022 : Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work;on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and fillingbrick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on thebrick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete asdirected by the Engineer-in-charge. |
| 179 | od130331/2021_2022 : Supplying approved make PVC gully trap of size 160x110mm and CI grating;150mmx150mm size and light duty C.I cover with frames 300mmx300mm size (inside) the weight of cover to;be not less than 4.5kg and frame to be not less than 2.7kg (CI MH cover and frame as per IS:1726) single;sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm, 115 thick brick wall in CM 1:6 on a foundation of PCC 1:4:8. 100mm thick;plastering inside with CM 1:3, 12mm thick with a neat cement flushing coat and conveying to site, cleaning,;installing and testing approved make PVC gully trap with 160mm outlet (fabricated), surrounding with CC;1:1.5:3, 150x150mmm, top with CI grating above the PVC gully trap and light duty CI cover and frame overthe chamber including cost of all materials, etc complete as per approved drawing and as directed byEngineer-in-Charge. |
| 180 | od130332/2021_2022 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover(light duty) the weight of the cover to be not less than 32 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by theEngineer- in-Charge |
| 181 | od130333/2021_2022 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges, making good the walls etc complete as directed by the Engineer-in-Charge 65 mm dia |
| 182 | od130334/2021_2022 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges, making good the walls etc complete as directed by the Engineer-in-Charge. 100mm dia |
| 183 | od130335/2021_2022 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges, making good the walls etc complete as directed by the Engineer-in-Charge. 80mm Dia |
| 184 | od130336/2021_2022 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer-in-Charge. 65mm Dia |
| 185 | od130337/2021_2022 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete asdirected by the Engineer-in-Charge. 80mm Dia |
| 186 | od130338/2021_2022 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m lengthincluding cost and conveyance of all materials,labour charges,making good the walls etc complete asdirected by the Engineer-in-Charge. 100mm Dia |
| 187 | od130339/2021_2022 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller,mechanical seal, complete with motor, base plate, foundation bolts, nuts,pressure guage and allaccessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of allmaterials,labour chargesetc complete as directed by the Engineer in charge at all levels;Capacity:8 m3/hr Head: 15m |
| 188 | od130340/2021_2022 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 32mm Y type strainer |
| 189 | od130341/2021_2022 : Providing and fixing CP brass robe hook etc completetesting and commissioning to the satisfaction of Engineer in Chargeat all levels.(Models: Jaquar catalogue no:AKP-35791P or equivalent and the equivalent shall be approved by the Engineer in charge) |
| 190 | 50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2 |
| 191 | 50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2 |
| 192 | 50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2 |
| 193 | 50.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2 |
| 194 | od130342/2021_2022 : Providing and fixing concealed floor trapincluding SS cockroach free floor grating with cup etc.complete, testing and commissioning to the satisfaction of Engineer in Charge at all levels. |
| 195 | 2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 196 | od130343/2021_2022 : Supplying and fixing of open well submerssible pump, with CI construction, CI impeller complete with motor, base plate, nuts, pressure gauge and all accessories. and working with 415V, 3ph and50 Hz frequencyincluding cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels.Capacity : 9m3/hr Head : 23 m |
| 197 | od130344/2021_2022 : Supplying and fixing C.I. cover with frame for manholes : 600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works includingcost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge. |
| 198 | od130345/2021_2022 : Providing and fixing water heater of storage capacity 6 litres of approved quality and make including cost and conveyance of all materials labour charges ,lead, lift,cutting and making good the walls,slabs,floors wherever required as per direction of Engineer-In charge at all levels(Models: Jaquar catalogue no: ELENA or equivalent and the equivalent shall be approved by the Engineer in charge) |
| 199 | od130346/2021_2022 : Supplying, laying, andjointing schedule 40 UPVC ASTM pipe and Schedule 80 ASTM-UPVC specials of approved make such as tees elbows, unions,bends,sockets bends,flanges, reducers, end caps,saddles, plugs,coupling, etc. including cost of all jointing materials as directed by Engineer in charge at all levels 65 mm inner dia pipes |
| 200 | od130347/2021_2022 : Supplying, laying, andjointing schedule 40 UPVC ASTM pipe and Schedule 80 ASTM-UPVC specials of approved make such as tees elbows, unions,bends,sockets bends,flanges, reducers, end caps,saddles, plugs,coupling, etc. including cost of all jointing materials etc complete as directed by Engineer in charge at all levels -50 mm inner dia pipes |
| 201 | od130348/2021_2022 : Supplying, laying, and jointing schedule 40 UPVC ASTM pipe and Schedule 80 ASTM-UPVC specials of approved make such as tees elbows, unions,bends,sockets bends,flanges, reducers, end caps,saddles, plugs,coupling, etc. including cost of all jointing materials etc complete as directed by Engineer in charge at all levels -80 mm inner dia pipes |
| 202 | od130503/2021_2022 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m lengthincluding costand conveyance of all materials,labour charges,making good the walls etc complete asdirected bythe Engineer in Charge. 150mm |
| 203 | 18.31.3.2 : Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc.(the tail pieces if required will be paid separately):150 mm diameter Class II |
| 204 | 50.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall |
| 205 | 50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall |
| 206 | Supply,Fixing&CommissoningofPopupsprinklerfull/partcirclehaving radiusofthrow15m-23m&flowof0.09-0.61ltr./sec.atanoperative pressure of 2.5 - 4.5 kg/cm.sq. , The sprinkler is gear driven rotary typewith slipclutchmechanismandheavydutyretractspring.memoryarc ,non strippableand brass reinforced nozzle turret ,left right both side arc adjustment,Memory arc technology,part and fullcircle in same sprinkler .The sprinklershallhavemulti-function,pressure-activatedwipersealforlow pressure opreation a The sprinkler shall have internal Seal - A - Matic device which prevents low head drainage (upto 3.1m) & hence puddling & erosion. Thebody of sprinkler is of non - corrodible, heavy duty, ABS plastic. Work has to be executed as per the approved drawings and/or as per the directions of the Engineer-in-charge.Rate inclusive ofall materials, fittings, labour,transportation complete. |
| 207 | Supply,Fixing & Commissoning of Sod Cup Kit allows users togrow turf on thecapofthe rotors.Thisallowsforanearlyinvisible installationfor applicationssuchassportsfields.Theruggedconstructionofthe CupKit providesmaximumdurabilitywhilemaintainingmaximum player safety.Integralpullupslot.Easyarcadjustmentafterinstallation through innercup.Drainholestopromotehealthy turfgrowth.Workhastobe executedaspertheapproveddrawingsand/orasperthedirectionsofthe Engineer-in-charge. Rate inclusiveof all materials,fittings,labour,transportation complete. engineering plastic. |
| 208 | Supply,Fixing&Commissoningof 1\"PopupConnectingSwingjoint Assembly.ThetubingshallbemadeofUPVC ,aworkingpressureof5.5 kg/cm2at43oCandasurgepressureof16.6kg/cm2.Thefittingsshallbe madeofUVresistantthermoplastic. Workhastobeexecutedasperthe approveddrawingsand/orasperthedirectionsoftheengineer-incharge. Rate inclusive of all materials,fittings,labour,transportation complete. |
| 209 | Supply,Fixing & Commissoning of HDPE service saddle ofvarying size with pressureratingofPN10.Workhastobeexecutedaspertheapproved drawings and/or as per the directions of the engineer-in charge.Rate inclusive of all materials,fittings,labour,transportation complete. |
| 210 | VALVES & ACCESSORIES |
| 211 | Supply,Fixing & Commissoning of PVC Ball Valve,security pivot to maintain leverinspace,double watertightjoint,directinjectionstem,non mechanical,with a base which permits maximum penetration into the valve of size 63mm withpressureratingPN10.Workhastobeexecutedaspertheapproved drawings and/or as per the directions of the Engineer-in-charge. Rate inclusive of all materials,fittings,labour,transportation complete. |
| 212 | Supply,Fixing &Commissoningofa double acting1/2\" Air release valve, madeofHDPEorhighergradematerial.TheAirreleasevalveshallbe capableofbothreleasingandadmittingairfromandintotheline.The working pressure shall be 5 bar.Work has to be executed as per the approved drawings and/or as per the directions of the Engineer-in-charge. Rate inclusive of all materials,fittings,labour,transportation complete. |
| 213 | Supply,Fixing&Commissoningof12\"RectangularValveBox madeof HDPEor higher grade material, with green lid and corrugated structure withuniqueshovel accessslotandboltholeknockout. Workhastobe executedaspertheapproveddrawingsand/orasperthedirectionsofthe engineer-in-charge. Rateinclusive ofall materials, fittings, labour, transportation complete. |
| 214 | Supply,Fixing&Commissoningof6\"Round boxofHDPE orhigher grade material, withgreenlid and corrugated structure with unique shovel accessslotandboltholeknockout.Workhastobeexecutedasperthe approved drawings and/or as per the directions of the Engineer-in-charge. Rate inclusive of all materials, fittings, labour,transportation complete. |
| 215 | Supply,Fixing & Commissoning of 1.5 inch quickcoupling valve made up of solid brass with locking cover corrosion resistant and stainless steel spring. Workhastobeexecutedaspertheapproveddrawingsand/orasperthe directionsofthe Engineer-in-charge. Rate inclusive ofall materials,fittings,labour,transportation complete. |
| 216 | Supply,Fixing&Commissoningofbrasskeythreadsintotopofquick coupling valve to provide water access.Work hasto be executed asper the approved drawings and/or as per the directions of the Engineer-in-charge. Rate inclusive of allaterials,fittings,labour,transportation complete. |
| 217 | FILTERATION UNIT |
| 218 | Supply,Fixing & Commissoning of 3\" Disc Filtermade of HDPE having an suitable inletconnections,tocreateahelicaleffectintheincoming water,spinningparticulateinsuspensionawayfromthefilteringelementandso minimizing cleanings frequency ,3/4\" outlet for flushing at bottom of filter & maximumworkingpresure of12 Bars.Workhasto be executedasperthe approved drawings and/or as per the directions of the Engineer-in-charge. Rate inclusive of all materials,fittings,labour,transportation complete. |
| 219 | PUMPING UNIT |
| 220 | Supply,Fixing&CommissoningofMonoblocoropenwell submercible pumpset of having dischargeand headof design flow.Duty of Pump :6.50 lps / Each Pump,Pressure Head Range= 55 - 60 Mtr.No. of Pumps : 1 Working + 0 Standby/.Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials, fittings, labour,transportation complete. |
| 221 | Supply,Fixing&Commissoningofcontrolpanel suitableforpumpset havingpanelbox madeofCRCAsheetof2mmthicknessandfixed alongwithfollowingaccessoriesDOL starter,start/stoppushbuttons, Ammeter , Single phase preventor, Voltmeter , Indicating lamps , MCB , Dry level guard sensor with control cable, etc. Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete. |
| 222 | Supply,Fixing & Commissoning of Suction ,Delivery & Header Pipesof size suitable for the pump flow ( ASTM sch 40/80 or PVC 10Kg/cm2). Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials ofapproved make, fittings, labour, transportation complete. |
| 223 | Supply,Fixing &CommissoningofCI control Valve,ButterflyValvein mainline forbypassandflowdiversionofapprovedquality withpressure rating of PN 10. Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete. |
| 224 | Supply,Fixing & Commissoning of 2\" gun metal Non Return Valve PN 10 with all accessories to prevent back flow. Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make, fittings,labour,transportation complete. |
| 225 | Supply,Fixing&CommissoningofPVC Pressurereleasevalve2\"withall accessories . Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete. |
| 226 | Supply,Fixing&CommissoningofCastIronPaddleWheelWaterMeter Metal Flanged of pressure rating 10 Bar with all accessories . Work has to be executedaspertheapproveddrawingsand/orasperthedirectionsofthe engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete. |
| 227 | Automation Equipment |
| 228 | Supply,Fixing&Commissoningof14Awgcable withhighmolecular weight polyethelene and applications upto 600volts , temperature upto - 55 to+ 60 deg centigrade ,soft drawnbarecoppermeetingASTM B3, tensile strenth 1400PSI for two way communication betwee nsolenoid valvel and decoders complete .Work has to be executed as per the approved drawings and/orasperthedirectionsoftheEngineer-in-charge.Rateinclusiveofall materials of approved make,fittings,labour,transportation complete. |
| 229 | Supply,Fixing &Commissoningof ASTMStation ModularController UV resistant,wall mount case,with LCD display ,non volatile memory for 100years,10KV surge protectionwith removablefront panel and programmableunderbatteryinoffice,totalruntimecalculator,shortdetect errors,onetouchwatering,wityhcontractdefaultprogrames,slowclosing valve removable battery withsensorterminals Workhasto beexecuted as pertheapproveddrawingsand/orasperthedirectionsoftheengineer-in- charge. Rate inclusive ofall materials of approved make, fittings, labour, transportation complete. |
| 230 | Supply,Fixing&Commissoningof3\" Solenoidglobe Valvesascentral shut off valve with fabric reinforced diaphramand rugged PVC construction,compatibleandslowclosingtopreventwaterhammer,pressureratingupto 0,7 to 10 bar and maximum flow of 10 to 100 m3/h,max water temp. upto 60°C with24 VAC - 50 Hz,coil resistance 30ohm withprovision to attach PressureRegulatingModule(Dial). Workhastobeexecutedasperthe approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete. |
| 231 | Supply,Fixing&Commissoningof2\"Solenoidglobe Valveswithfabric reinforceddiaphram andruggedPVCconstruction ,compatibleandslow closing to prevent water hammer,pressure rating upto 10.4bar and maximum flowof150GPM,maxwatertemp.upto42degreecentigrade,with24AC solenoid,current rating 0.41A @60Hz,coil resistance 30 ohm withprovision to attachPressure Regulating Module (Dial). Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete. |
| 232 | Supply,Fixing &CommissoningofPressureRegulatingModule(Dial)to Maintainconstantoutlet pressurebetween 1.04 to6.9 bar. Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make, fittings, labour, transportation complete |
| 233 | Supply,Fixing &Commissoningof directbury-onwire connectorwith strainrelief, UL486D certified ,withwaterproofsiliconsealant,fits wirefrom22gato6gaasperspecificationscomplete.Workhastobe executedaspertheapproveddrawingsand/orasperthedirectionsofthe engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete |
| 234 | Supply,Fixing & Commissoningof moisture sensing device ,to measure soil temp,EC ,Moisture levelcomplete to convert as smart controller,with corrossion resistant sensorand setting thershhold moisture level . Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete. |
| 235 | Supply,Fixing&Commissoningof ASTMautomaticrainshutoffdevice, latching hinge with multiple rainfall settings 5mm to 20mm UL CUL listed andCEapprovedcomplete.Workhastobe executedaspertheapproved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete. |
| 236 | Supply,Fixing & Commissoning of Pump relay24 ACPLA relay , stabiliser 300watts. Work has to be executed as per the approved drawings and/or as per thedirectionsoftheengineer-in-charge.Rateinclusiveofallmaterialsof approved make,fittings,labour,transportation complete. |
| 237 | 1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 238 | 1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 239 | 1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 240 | 1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required. Group C |
| 241 | 1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 242 | 1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 243 | 1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push |
| 244 | 1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 245 | 1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 246 | 1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings). |
| 247 | od134402/2021_2022 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 248 | CABLE LAYING |
| 249 | 7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm |
| 250 | 7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 251 | 7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 252 | 7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 253 | 7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm |
| 254 | 7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm |
| 255 | 7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 256 | 7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 257 | 7.2.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm |
| 258 | 4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 259 | 14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia |
| 260 | 14.14.1 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100 mm dia |
| 261 | LIGHT FIXTURES AND FANS (OD) |
| 262 | od134126/2021_2022 : Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattageof 10+/-2 Watts,lumen output of luminaire greater than 1000, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No:Wipro LL20-121-XXX-60-XX or Crompton Greaves DMLN1LT16+LT8 or equivalent approved make. |
| 263 | od134129/2021_2022 : Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattage of 20+/-2 Watts,lumen output of luminaire greater than 2000, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No:Philips BN021C LED20S PSU NW GR or Wipro LL20-221-XXX-60-XX or Crompton Greaves DMLN1LT16+LT16 or equivalent approved make. |
| 264 | od134149/2021_2022 : Supply, of LED Flood light luminaire of IP66 protected, pressure die cast aluminium housing body with optimal heat sink, with maximum system wattage 350 W with rated life of L70 @ 50,000 hours,CRI greater than or equal to 70 with system lumens not less than 38500 and system efficiency greater than or equal to100 lumen/watt.The Light fitting shall be with all required accessories suitable for mounting in (48-60)mm. The luminaire should meet all the technical specifications as mentioned. (Make: bajaj: BJFL-350-MB/LB or equivalent approved make) |
| 265 | od134150/2021_2022 : Supply of 10+/-2w LED Bulkheadfitting with die cast aluminium housing, PC diffuser and IP65 Protection suitable for operation on 230V 50Hz AC, wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire and making good the surface as required. (Make: Philips :WT202W led6s cw psu s2 PC or Crompton LBH-10-CDL or equivalent approved make) |
| 266 | od134151/2021_2022 : Supply, installation, testing and commissioningof6m long Hot dipped GI polewith foundation , built- in control box prewired, with pole suitable for mountingLEDluminairie with lamp , concealed wiring with 3Cx 2.5 sq.mm copper wire from the control box to light fixture, provision for mounting MCB in the control boxas required and all other accessories completeoncivil foundation. Along with LED Luminary with pressure die cast Aluminium alloy housing and polycarbonate diffuser, inbuilt driver,system wattage maximum of 40(+/-5) watts, System efficacy not less than 110 lumen per watt , and lumen output greater than 4200 lumen, power factor >0.9, IP 66 compliant including all necessary accessories as required complete. Note:Incoming and outgoing cable at termination box shall be terminated with glands properly.(Pole Make : UNIQUE POLES or equivalent approved make. Luminairie Make: WIPRO -LR02-451-XXX-57-XXor equivalent approved make).The rate for foundation shall be measured under civil items. |
| 267 | 1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 268 | od134152/2021_2022 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: Orient Smart Air Exhaust or equivalant approved make) |
| 269 | 1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required. |
| 270 | 1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep |
| 271 | od134153/2021_2022 : Supply installation, testing and commissioning of octagonal pole of 12 meter for mounting 6 nos of 350W LED flood light or as per actual lux requirements.The pole shall be hot dipped galvanized and fixing assembly on the pole top. The pole with flood light mounting assembly and built-in cylindrical GI control box shall be of same material .The control gear box is prewired with FP MCB, FP connector for easy loop-in loop-out suitable for 3phase 4 wire AC supply. From this control gear box to the luminaires 5 core 2.5 sq mm copper flexible XLPE cable through flexible conduit shall be used. The pole shall have provision for connecting the earth wire and cable gland arrangement..The mast has been designed considering base wind speed i.e. 39 m/s. Mast will be equipped with monkey ladder to access the top for maintenance. The Top dia shall be 100mm and bottom shall be 240mm with 3mm sheet thicikness. Minimum galvanizing thickness of 70 microns should be maintained uniform throughout the pole.Construction of shallow foundation with M20 grade concrete for the poleconsidering the safe soil bearing capacity at site as 10 T/sqmtr at 2.5 metre depth. |
| 272 | od134154/2021_2022 : Supply of LED surface mounted down light made of pressure die cast aluminium, with corrosion resistant powder coating using nano technology along with driver,system wattageof 12 Watts,colour temperature-4000Kfixture with lumen output of lampnotless than 1000 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 85 lumen/watt and including all necessary accessories as required complete Make:- Cat No: : LT- L01240S000 LUNAR MID or equivalent approved make |
| 273 | 7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate withinscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixingthe same in ground as required. |
| 274 | SUPPLY OF CABLE (OD) |
| 275 | od134123/2021_2022 : "Supply of 4C 6 Sq.mm Al 1.1KVgrade XLPE insulated, PVC sheathed, armoured Aluminiumconductor cable conformingtoIS7098(Part1)amended upto date. |
| 276 | od134137/2021_2022 : Supply of following 3C 4 sqmm Cu size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date. |
| 277 | od134140/2021_2022 : Supply of following 2C 6 Sq mm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminiumconductor cable conforming to IS 7098 (Part 1) amended upto date |
| 278 | od134143/2021_2022 : Supply of following 3C 6 Sq.mm Alsize 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date |
| 279 | od134144/2021_2022 : Supply of following 4C 2.5 sqmm Cu size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date |
| 280 | od134146/2021_2022 : Supply of following 4C 35 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date |
| 281 | od134148/2021_2022 : Supply of following 3.5C 120 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. |
| 282 | DB AND MCCB\"S (OD) |
| 283 | od134133/2021_2022 : Supplyinstallation, testing and commissioning of FASD starter in sheet steel enclosure for 6 HP , 3 PHASEmotor including auxilliary contactors, capacitor , and all necessary accessories as required complete |
| 284 | od134136/2021_2022 : Supplyinstallation, testing and commissioning of DOL starter in sheet steel enclosure upto5 HP , 3PHASEmotor including auxilliary contactors, capacitor , and all necessary accessories as required complete |
| 285 | od134139/2021_2022 : Supply and fixing outdoor type START/STOP (2way) push button station (IP65) includingall the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalentapproved make) |
| 286 | od134141/2021_2022 : Supplyand fixing of following 2 pole 25 amps. (415 Volts),30mA sensitivity rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required |
| 287 | 2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door |
| 288 | od134145/2021_2022 : Supply and fixingof following40 A -63ATP MCB,rating, 10 KA, Miniature Circuit Breakersas required. |
| 289 | od134147/2021_2022 : Supplyand fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 4 pole 63 amps. (415 Volts),100mA sensitivity |
| 290 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 291 | 2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 292 | 2.11 : Supplying and fixing single pole blanking plate inthe existing MCB DB complete etc. as required. |
| 293 | 90.11.1.16 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 294 | 2.2.2 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required125 Amp,16 KA,TPMCCB |
| 295 | 90.14.28.2 : S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor |
| 296 | 90.11.1.19 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 297 | CABLE TERMINATION (OD) |
| 298 | od134124/2021_2022 : "Supplying and makingend termination with brass compression gland and aluminium lugs for 4C 6 Sq.mm Al XLPE insulated PVC sheathed aluminium conductor cableof1.1 kVgrade as required." |
| 299 | od134131/2021_2022 : Supplying and making end termination with brasscompression gland and copper lugs for following 3C 4 sqmm Cusize of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required |
| 300 | od134135/2021_2022 : Supplying and making end termination with brass compression gland and aluminium lugs for following 3C 6 Sq.mm Alsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required |
| 301 | od134142/2021_2022 : Supplying and making end termination with brasscompression gland and copper lugs for following 4C 2.5 Sq.mm Cu size of PVC insulated and PVC sheathed / XLPEcopperconductor cable of 1.1 KV grade as required. |
| 302 | 9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm) |
| 303 | 9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm) |
| 304 | 9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 305 | EARTHING |
| 306 | od134128/2021_2022 : Providing and fixing 25*6 mm GI/Cu strip/wire on surface or in recess for connections etc. as required |
| 307 | od134130/2021_2022 : Supplying and laying 10 SWGG.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating withnut, bolt, spring, washer etc. as required |
| 308 | od134132/2021_2022 : Supplying and laying 8 SWG GIat 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt spring washer spaced at 50mm) |
| 309 | od134134/2021_2022 : Supplying and layingof 25*6 mm G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt spring washer spaced at 50mm) |
| 310 | od134138/2021_2022 : Providing and fixing of 3.15mm Cu (10 SWG)GI/Cu strip/wire on surface or in recess for connections etc. as required. |
| 311 | 5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required |
| 312 | ELECTRIC PANELS (OD) |
| 313 | od134125/2021_2022 : Supply, installation, testing and commissioning ofKSEB metering panel, suitable for accomodating 3ph KSEB CT operated TOD meter and consisting of 3 nos. of 125A cutout with HRC fuse, neutral link, 125 A FP MCCB with earth fault release in separate chamber,inter connections etc. as required, and necessary supports to be fabricated out of 14 SWG CRCA sheet with locabledoor with sealing facility having glass window for energymeter, sealing facility for KSEB, top canopy and necessaryoverhang, undergone seven tank process ,powder coated finish andall mountingaccessories as required .The panel shall be with allaccessories as per drawing specification. |
| 314 | od134127/2021_2022 : Supply, Installation, Testing and Commissioning of Outdoor Lighting Panel (ODP) cubicle type, totally enclosed, IP 65, pedestal mounted, free standing with top canopy,dust and vermin proof, water proof suitable for operation on 3 phase, 415 V, 50Hz AC supply with provision for fixing incoming outgoing switches fabricated using 2mm thick CRCAsheet, powder coated, including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc., The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) including following switchgears accessories for the LT Panel.The panel shall be with allaccessories as per drawing specification.INCOMER 63 A, FP, 16kA, MCB- 1 NoBUSBARS 63AAL BusbarINSTRUMENTSSurge protection device -Type1 with protection fuse as per SLD (0-63)A ammeter Acc. class 1 with 90 deg defl. scale - as per SLD 4A, C curve SP MCB - as per SLD (0-63A) Voltmeter with selector switch -as per SLD RYB indication lamp, LED type - as per SLD OUTGOINGS 25 A, FP RCCB (100mA)-10 Nos 25 A C Curve FP MCB-10 Nos |
AI Tender Summary
Tender Timeline
May 21, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedMay 31, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJun 03, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender