Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited-UPRVUNL has published The Work Of Providing Support Services In Maintenance Of Candi Equipments And Breakdown Maintenance Of All Units Of 3X210 Mw, Atps, Anpara During The Year 2022 - 2023.- 1 Overhauling & Servicing Of Limitorque Make Actuators Smb-000 2 Overhauling & . Submission Date for this Tender is 17-06-2022. Kitchen Equipment Tenders in anpara Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Overhauling & Servicing of Limitorque make actuators SMB-000 |
2 | Overhauling & Servicing of Limitorque make actuator SMB-00 |
3 | Overhauling & Servicing of Limitorque make actuator SMB-0 |
4 | Overhauling & Servicing of Limitorque make actuator SMB-1 |
5 | Overhauling & Servicing of Limitorque make actuator SMB-2 |
6 | Overhauling & Servicing of Limitorque make actuator SMB-3 |
7 | Overhauling & Servicing of Limitorque make actuator K-1000 F16 A / K-800 |
8 | Overhauling & Servicing of Limitorque make actuator K-600 F 14 A / K-500 |
9 | Overhauling & Servicing of Limitorque make actuator K-300 G1/G2 |
10 | Overhauling & Servicing of Limitorque make actuator K-150 F 10 A |
11 | Overhauling & Servicing of Limitorque make actuator K- 60 F 10 A |
12 | Overhauling & Servicing of Limitorque make actuator K-30F 10 A |
13 | Overhauling & Servicing of EEMG DC OE-140 C |
14 | Overhauling & Servicing ofSIEMENS |
15 | Overhauling & Servicing of AUMA |
16 | Overhauling & Servicing of L-120-20 |
17 | Overhauling & Servicing of Actuator driven damper drive device |
18 | Dismantling & Re-installation of Limitorque make actuator SMB-000 |
19 | Dismantling & Re-installation of Limitorque make actuator SMB-00 |
20 | Dismantling & Re-installation of Limitorque make actuator SMB-0 |
21 | Dismantling & Re-installation of Limitorque make actuator SMB-1 |
22 | Dismantling & Re-installation of Limitorque make actuator SMB-2 |
23 | Dismantling & Re-installation of Limitorque make actuator SMB-3 |
24 | Dismantling & Re-installation of Rotork make actuator K-1000 F16 A / K-800 |
25 | Dismantling & Re-installation of Rotork make actuator K-600 F 14 A / K-500 |
26 | Dismantling & Re-installation ofRotork make actuator K-300 G1/G2 |
27 | Dismantling & Re-installation of Rotork make actuator K-150 F 10 A |
28 | Dismantling & Re-installation of Rotork make actuator K- 60 F 10 A |
29 | Dismantling & Re-installation of Rotork make actuator K-30F 10 A |
30 | Dismantling & Re-installation of actuator EEMG DC OE-140 C |
31 | Dismantling & Re-installation of SIEMENS make actuator |
32 | Dismantling & Re-installation of AUMA make actuator |
33 | Dismantling & Re-installation actauator of L-120-20 |
34 | Dismantling & Re-installation of Actuator driven damper drive device |
35 | Repairing of Actuator drive sleeve unit of M/s Rotork make electrical actuators K-1000 /800 |
36 | Repairing of Actuator drive sleeve unit of M/s Rotork make electrical actuators K - 600 / 500 |
37 | Repairing of Actuator drive sleeve unit of M/s Rotork make electrical actuatorsK - 300 |
38 | Repairing of Actuator drive sleeve unit of M/s Rotork make electrical actuatorsK - 150 / 60 / 30 |
39 | To make hole, threading, milling and machining of stem drive nut as per actuator drive stemfor Limitorque make Actuators |
40 | To make hole, threading, milling and machining of stem drive nut as per actuator drive stemfor Rotork make Actuators |
41 | Full load Feed water control valve BF-29 |
42 | Full load Feed water control valve BF-30 |
43 | Low load Feed water control valve BF-31 |
44 | Low load Feed water control valve BF-32 |
45 | BFP-A scoop control system |
46 | BFP-B scoop control system |
47 | BFP-C scoop control system |
48 | Super heater spray control valve BF-63 |
49 | Super heater spray control valve BF-64 |
50 | Super heater spray control valve BF-65 |
51 | Super heater spray control valve BF-66 |
52 | Re-heater spray control vave BF-79 System |
53 | Re-heater spray control vave BF-80 System |
54 | Re-heater spray control vave BF-81 System |
55 | Re-heater spray control vave BF-82 System |
56 | Vane control system of ID-A |
57 | Vane control system of ID-B |
58 | Vane control system of FD-A |
59 | Vane control system of FD-B |
60 | Vane control system of PA-A |
61 | Vane control system of PA-B |
62 | Burner tilt control system(Corner-1) |
63 | Burner tilt control system(Corner-2) |
64 | Burner tilt control system(Corner-3) |
65 | Burner tilt control system(Corner-4) |
66 | Secondary air damper control system(corner-01) |
67 | Secondary air damper control system(corner-02) |
68 | Secondary air damper control system(corner-03) |
69 | Secondary air damper control system(corner-04) |
70 | Mill-A Control System |
71 | Mill-B Control System |
72 | Mill-C Control System |
73 | Mill-D Control System |
74 | Mill-E Control System |
75 | Mill-F Control System |
76 | Fuel firing control system(corner-1) |
77 | Fuel firing control system(corner-2) |
78 | Fuel firing control system(corner-3) |
79 | Fuel firing control system(corner-4) |
80 | Site equipment of SCP1 to SCP15 |
81 | Sequential control system of APH |
82 | Sequential control system of ID Fan |
83 | Sequential control system of FD Fan |
84 | Sequential control system of PA fan |
85 | Sequential control system of BFP |
86 | Annunciation system CP1 TO CP12 |
87 | Annunciation system power supply |
88 | ACS System power supply |
89 | Furnace draft high left side protection |
90 | Furnace draft high right side protection |
91 | Furnace draft low left side protection |
92 | Furnace draft low right side protection |
93 | Primary air header pressure low protection |
94 | Primary air header pressure very low protection |
95 | HP heater 5 level control loop |
96 | HP heater 6 level control loop |
97 | LP heater-1 level control loop |
98 | LP heater-2 level control loop |
99 | LP heater-3 level control loop |
100 | DM-15 Control valve system |
101 | DM-16 Control valve system |
102 | Dearator level control loop |
103 | Minimum recirculation control loop |
104 | Repairing, Servicing and Reconditioning of Hydramotor Valves actuator with limit switch assemblies. |
105 | Rewinding, Varnishing, Servicing and Reconditioning of defective and burnt solenoid of DW-109/110 valve. |
106 | Replacement of various types of actuator diaphragms |
107 | Repairing of defective discrepancy switch |
108 | Repairing of definite time delay relay (VTT). |
109 | Replacement of defective level switch |
110 | Repairing of control relay (VAJC). |
111 | Repairing of defective pressure switch. |
112 | Repairing of defective air filter cum regulator. |
113 | Repairing of AC/DC regulated power supply 240VAC/24VDC. |
114 | Welding/cutting/grinding of oil & air pipe line of 16 to 20mm size (Rate given for replacement of pipe line per meter/attending leakage point). |
115 | Rewinding/varnishing of defective transformer 110V/24V,1 Phase. |
116 | Replacement of defective hot air gate power cylinder. |
117 | Repairing of defective retractor assembly. |
118 | Repairing of defective hot air gate solenoid valve. |
119 | Repairing of defective heavy duty cum operated limit switch. |
120 | Repairing of defective hot air gate power cylinder. |
121 | Replacement of defective vane control/burner tilt power cylinder |
122 | Replacement of defective BFPs positioned along with its power cylinder and accessories. |
123 | Repairing of defective BFPs scoop tube actuator’s positioned along with its power cylinder. |
124 | Replacement of defective/old PU Tube/Teflon Tube of BFPs scoop tube actuator’s |
125 | Repairing of defective HOTV solenoid valve.. |
126 | Repairing of defective HOTV limit switch. |
127 | Repairing of defective CRL/CR relay. |
128 | Repairing of defective boiler manual trip push button cum indicator. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy