}

The Work Of Providing Support Services In Maintenance Of Candi Equipments And Breakdown Maintenance Of All Units Of 3X210 Mw, Atps, Anpara During The Year 2022 - 2023.- 1 Overhauling & Servicing Of Limitorque Make Actuators Smb-000 2 Overhauling & , anpara-Uttar Pradesh

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited-UPRVUNL has published The Work Of Providing Support Services In Maintenance Of Candi Equipments And Breakdown Maintenance Of All Units Of 3X210 Mw, Atps, Anpara During The Year 2022 - 2023.- 1 Overhauling & Servicing Of Limitorque Make Actuators Smb-000 2 Overhauling & . Submission Date for this Tender is 17-06-2022. Kitchen Equipment Tenders in anpara Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32320462
The Work Of Providing Support Services In Maintenance Of Candi Equipments And Breakdown Maintenance Of All Units Of 3X210 Mw, Atps, Anpara During The Year 2022 - 2023.- 1 Overhauling & Servicing Of Limitorque Make Actuators Smb-000 2 Overhauling &
Open Tender
Indian
Uttar Pradesh
anpara
17-06-2022

Tender Details

The Work Of Providing Support Services In Maintenance Of Candi Equipments And Breakdown Maintenance Of All Units Of 3X210 Mw, Atps, Anpara During The Year 2022 - 2023.- 1 Overhauling & Servicing Of Limitorque Make Actuators Smb-000 2 Overhauling & Servicing Of Limitorque Make Actuator Smb-00 3 Overhauling & Servicing Of Limitorque Make Actuator Smb-0 4 Overhauling & Servicing Of Limitorque Make Actuator Smb-1 5 Overhauling & Servicing Of Limitorque Make Actuator Smb-2 6 Overhauling & Servicing Of Limitorque Make Actuator Smb-3 7 Overhauling & Servicing Of Limitorque Make Actuator K-1000 F16 A / K-800 8 Overhauling & Servicing Of Limitorque Make Actuator K-600 F 14 A / K-500 9 Overhauling & Servicing Of Limitorque Make Actuator K-300 G1 / G2 10 Overhauling & Servicing Of Limitorque Make Actuator K-150 F 10 A 11 Overhauling & Servicing Of Limitorque Make Actuator K- 60 F 10 A 12 Overhauling & Servicing Of Limitorque Make Actuator K-30F 10 A 13 Overhauling & Servicing Of Eemg Dc Oe-140 C 14 Overhauling & Servicing Ofsiemens 15 Overhauling & Servicing Of Auma 16 Overhauling & Servicing Of L-120-20 17 Overhauling & Servicing Of Actuator Driven Damper Drive Device 18 Dismantling & Re-Installation Of Limitorque Make Actuator Smb-000 19 Dismantling & Re-Installation Of Limitorque Make Actuator Smb-00 20 Dismantling & Re-Installation Of Limitorque Make Actuator Smb-0 21 Dismantling & Re-Installation Of Limitorque Make Actuator Smb-1 22 Dismantling & Re-Installation Of Limitorque Make Actuator Smb-2 23 Dismantling & Re-Installation Of Limitorque Make Actuator Smb-3 24 Dismantling & Re-Installation Of Rotork Make Actuator K-1000 F16 A / K-800 25 Dismantling & Re-Installation Of Rotork Make Actuator K-600 F 14 A / K-500 26 Dismantling & Re-Installation Ofrotork Make Actuator K-300 G1 / G2 27 Dismantling & Re-Installation Of Rotork Make Actuator K-150 F 10 A 28 Dismantling & Re-Installation Of Rotork Make Actuator K- 60 F 10 A 29 Dismantling & Re-Installation Of Rotork Make Actuator K-30F 10 A 30 Dismantling & Re-Installation Of Actuator Eemg Dc Oe-140 C 31 Dismantling & Re-Installation Of Siemens Make Actuator 32 Dismantling & Re-Installation Of Auma Make Actuator 33 Dismantling & Re-Installation Actauator Of L-120-20 34 Dismantling & Re-Installation Of Actuator Driven Damper Drive Device 35 Repairing Of Actuator Drive Sleeve Unit Of M / S Rotork Make Electrical Actuators K-1000 / 800 36 Repairing Of Actuator Drive Sleeve Unit Of M / S Rotork Make Electrical Actuators K - 600 / 500 37 Repairing Of Actuator Drive Sleeve Unit Of M / S Rotork Make Electrical Actuatorsk - 300 38 Repairing Of Actuator Drive Sleeve Unit Of M / S Rotork Make Electrical Actuatorsk - 150 / 60 / 30 39 To Make Hole, Threading, Milling And Machining Of Stem Drive Nut As Per Actuator Drive Stemfor Limitorque Make Actuators 40 To Make Hole, Threading, Milling And Machining Of Stem Drive Nut As Per Actuator Drive Stemfor Rotork Make Actuators 41 Full Load Feed Water Control Valve Bf-29 42 Full Load Feed Water Control Valve Bf-30 43 Low Load Feed Water Control Valve Bf-31 44 Low Load Feed Water Control Valve Bf-32 45 Bfp-A Scoop Control System 46 Bfp-B Scoop Control System 47 Bfp-C Scoop Control System 48 Super Heater Spray Control Valve Bf-63 49 Super Heater Spray Control Valve Bf-64 50 Super Heater Spray Control Valve Bf-65 51 Super Heater Spray Control Valve Bf-66 52 Re-Heater Spray Control Vave Bf-79 System 53 Re-Heater Spray Control Vave Bf-80 System 54 Re-Heater Spray Control Vave Bf-81 System 55 Re-Heater Spray Control Vave Bf-82 System 56 Vane Control System Of Id-A 57 Vane Control System Of Id-B 58 Vane Control System Of Fd-A 59 Vane Control System Of Fd-B 60 Vane Control System Of Pa-A 61 Vane Control System Of Pa-B 62 Burner Tilt Control System ( Corner-1 ) 63 Burner Tilt Control System ( Corner-2 ) 64 Burner Tilt Control System ( Corner-3 ) 65 Burner Tilt Control System ( Corner-4 ) 66 Secondary Air Damper Control System ( Corner-01 ) 67 Secondary Air Damper Control System ( Corner-02 ) 68 Secondary Air Damper Control System ( Corner-03 ) 69 Secondary Air Damper Control System ( Corner-04 ) 70 Mill-A Control System 71 Mill-B Control System 72 Mill-C Control System 73 Mill-D Control System 74 Mill-E Control System 75 Mill-F Control System 76 Fuel Firing Control System ( Corner-1 ) 77 Fuel Firing Control System ( Corner-2 ) 78 Fuel Firing Control System ( Corner-3 ) 79 Fuel Firing Control System ( Corner-4 ) 80 Site Equipment Of Scp1 To Scp15 81 Sequential Control System Of Aph 82 Sequential Control System Of Id Fan 83 Sequential Control System Of Fd Fan 84 Sequential Control System Of Pa Fan 85 Sequential Control System Of Bfp 86 Annunciation System Cp1 To Cp12 87 Annunciation System Power Supply 88 Acs System Power Supply 89 Furnace Draft High Left Side Protection 90 Furnace Draft High Right Side Protection 91 Furnace Draft Low Left Side Protection 92 Furnace Draft Low Right Side Protection 93 Primary Air Header Pressure Low Protection 94 Primary Air Header Pressure Very Low Protection 95 Hp Heater 5 Level Control Loop 96 Hp Heater 6 Level Control Loop 97 Lp Heater-1 Level Control Loop 98 Lp Heater-2 Level Control Loop 99 Lp Heater-3 Level Control Loop 100 Dm-15 Control Valve System 101 Dm-16 Control Valve System 102 Dearator Level Control Loop 103 Minimum Recirculation Control Loop 104 Repairing, Servicing And Reconditioning Of Hydramotor Valves Actuator With Limit Switch Assemblies. 105 Rewinding, Varnishing, Servicing And Reconditioning Ofdefective And Burnt Solenoid Of Dw-109 / 110 Valve. 106 Replacement Of Various Types Of Actuator Diaphragms 107 Repairing Of Defective Discrepancy Switch 108 Repairing Of Definite Time Delay Relay ( Vtt ) . 109 Replacement Of Defective Level Switch 110 Repairing Of Control Relay ( Vajc ) . 111 Repairing Of Defective Pressure Switch. 112 Repairing Of Defective Air Filter Cum Regulator. 113 Repairing Of Ac / Dc Regulated Power Supply 240Vac / 24Vdc. 114 Welding / Cutting / Grinding Of Oil & Air Pipe Line Of 16 To 20Mm Size ( Rate Given For Replacement Of Pipe Line Per Meter / Attending Leakage Point ) . 115 Rewinding / Varnishing Of Defective Transformer 110V / 24V, 1 Phase. 116 Replacement Of Defective Hot Air Gate Power Cylinder. 117 Repairing Of Defective Retractor Assembly. 118 Repairing Of Defective Hot Air Gate Solenoid Valve. 119 Repairing Of Defective Heavy Duty Cum Operated Limit Switch. 120 Repairing Of Defective Hot Air Gate Power Cylinder. 121 Replacement Of Defective Vane Control / Burner Tilt Power Cylinder 122 Replacement Of Defective Bfps Positioned Along With Its Power Cylinder And Accessories. 123 Repairing Of Defective Bfps Scoop Tube Actuator’S Positioned Along With Its Power Cylinder. 124 Replacement Of Defective / Old Pu Tube / Teflon Tube Of Bfpsscoop Tube Actuator’S 125 Repairing Of Defective Hotv Solenoid Valve.. 126 Repairing Of Defective Hotv Limit Switch. 127 Repairing Of Defective Crl / Cr Relay. 128 Repairing Of Defective Boiler Manual Trip Push Button Cum Indicator.

Key Value

Document Fees
INR 590 /-
EMD
INR 38000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: The work of Providing support services in maintenance of C&I equipments & breakdown maintenance of all units of 3X210 MW, ATPS, Anpara during the year 2022 - 2023.
Sl. No. Item Description
1Overhauling & Servicing of Limitorque make actuators SMB-000
2Overhauling & Servicing of Limitorque make actuator SMB-00
3Overhauling & Servicing of Limitorque make actuator SMB-0
4Overhauling & Servicing of Limitorque make actuator SMB-1
5Overhauling & Servicing of Limitorque make actuator SMB-2
6Overhauling & Servicing of Limitorque make actuator SMB-3
7Overhauling & Servicing of Limitorque make actuator K-1000 F16 A / K-800
8Overhauling & Servicing of Limitorque make actuator K-600 F 14 A / K-500
9Overhauling & Servicing of Limitorque make actuator K-300 G1/G2
10Overhauling & Servicing of Limitorque make actuator K-150 F 10 A
11Overhauling & Servicing of Limitorque make actuator K- 60 F 10 A
12Overhauling & Servicing of Limitorque make actuator K-30F 10 A
13Overhauling & Servicing of EEMG DC OE-140 C
14Overhauling & Servicing ofSIEMENS
15Overhauling & Servicing of AUMA
16Overhauling & Servicing of L-120-20
17Overhauling & Servicing of Actuator driven damper drive device
18Dismantling & Re-installation of Limitorque make actuator SMB-000
19Dismantling & Re-installation of Limitorque make actuator SMB-00
20Dismantling & Re-installation of Limitorque make actuator SMB-0
21Dismantling & Re-installation of Limitorque make actuator SMB-1
22Dismantling & Re-installation of Limitorque make actuator SMB-2
23Dismantling & Re-installation of Limitorque make actuator SMB-3
24Dismantling & Re-installation of Rotork make actuator K-1000 F16 A / K-800
25Dismantling & Re-installation of Rotork make actuator K-600 F 14 A / K-500
26Dismantling & Re-installation ofRotork make actuator K-300 G1/G2
27Dismantling & Re-installation of Rotork make actuator K-150 F 10 A
28Dismantling & Re-installation of Rotork make actuator K- 60 F 10 A
29Dismantling & Re-installation of Rotork make actuator K-30F 10 A
30Dismantling & Re-installation of actuator EEMG DC OE-140 C
31Dismantling & Re-installation of SIEMENS make actuator
32Dismantling & Re-installation of AUMA make actuator
33Dismantling & Re-installation actauator of L-120-20
34Dismantling & Re-installation of Actuator driven damper drive device
35Repairing of Actuator drive sleeve unit of M/s Rotork make electrical actuators K-1000 /800
36Repairing of Actuator drive sleeve unit of M/s Rotork make electrical actuators K - 600 / 500
37Repairing of Actuator drive sleeve unit of M/s Rotork make electrical actuatorsK - 300
38Repairing of Actuator drive sleeve unit of M/s Rotork make electrical actuatorsK - 150 / 60 / 30
39To make hole, threading, milling and machining of stem drive nut as per actuator drive stemfor Limitorque make Actuators
40To make hole, threading, milling and machining of stem drive nut as per actuator drive stemfor Rotork make Actuators
41Full load Feed water control valve BF-29
42Full load Feed water control valve BF-30
43Low load Feed water control valve BF-31
44Low load Feed water control valve BF-32
45BFP-A scoop control system
46BFP-B scoop control system
47BFP-C scoop control system
48Super heater spray control valve BF-63
49Super heater spray control valve BF-64
50Super heater spray control valve BF-65
51Super heater spray control valve BF-66
52Re-heater spray control vave BF-79 System
53Re-heater spray control vave BF-80 System
54Re-heater spray control vave BF-81 System
55Re-heater spray control vave BF-82 System
56Vane control system of ID-A
57Vane control system of ID-B
58Vane control system of FD-A
59Vane control system of FD-B
60Vane control system of PA-A
61Vane control system of PA-B
62Burner tilt control system(Corner-1)
63Burner tilt control system(Corner-2)
64Burner tilt control system(Corner-3)
65Burner tilt control system(Corner-4)
66Secondary air damper control system(corner-01)
67Secondary air damper control system(corner-02)
68Secondary air damper control system(corner-03)
69Secondary air damper control system(corner-04)
70Mill-A Control System
71Mill-B Control System
72Mill-C Control System
73Mill-D Control System
74Mill-E Control System
75Mill-F Control System
76Fuel firing control system(corner-1)
77Fuel firing control system(corner-2)
78Fuel firing control system(corner-3)
79Fuel firing control system(corner-4)
80Site equipment of SCP1 to SCP15
81Sequential control system of APH
82Sequential control system of ID Fan
83Sequential control system of FD Fan
84Sequential control system of PA fan
85Sequential control system of BFP
86Annunciation system CP1 TO CP12
87Annunciation system power supply
88ACS System power supply
89Furnace draft high left side protection
90Furnace draft high right side protection
91Furnace draft low left side protection
92Furnace draft low right side protection
93Primary air header pressure low protection
94Primary air header pressure very low protection
95HP heater 5 level control loop
96HP heater 6 level control loop
97LP heater-1 level control loop
98LP heater-2 level control loop
99LP heater-3 level control loop
100DM-15 Control valve system
101DM-16 Control valve system
102Dearator level control loop
103Minimum recirculation control loop
104Repairing, Servicing and Reconditioning of Hydramotor Valves actuator with limit switch assemblies.
105Rewinding, Varnishing, Servicing and Reconditioning of defective and burnt solenoid of DW-109/110 valve.
106Replacement of various types of actuator diaphragms
107Repairing of defective discrepancy switch
108Repairing of definite time delay relay (VTT).
109Replacement of defective level switch
110Repairing of control relay (VAJC).
111Repairing of defective pressure switch.
112Repairing of defective air filter cum regulator.
113Repairing of AC/DC regulated power supply 240VAC/24VDC.
114Welding/cutting/grinding of oil & air pipe line of 16 to 20mm size (Rate given for replacement of pipe line per meter/attending leakage point).
115Rewinding/varnishing of defective transformer 110V/24V,1 Phase.
116Replacement of defective hot air gate power cylinder.
117Repairing of defective retractor assembly.
118Repairing of defective hot air gate solenoid valve.
119Repairing of defective heavy duty cum operated limit switch.
120Repairing of defective hot air gate power cylinder.
121Replacement of defective vane control/burner tilt power cylinder
122Replacement of defective BFPs positioned along with its power cylinder and accessories.
123Repairing of defective BFPs scoop tube actuator’s positioned along with its power cylinder.
124Replacement of defective/old PU Tube/Teflon Tube of BFPs scoop tube actuator’s
125Repairing of defective HOTV solenoid valve..
126Repairing of defective HOTV limit switch.
127Repairing of defective CRL/CR relay.
128Repairing of defective boiler manual trip push button cum indicator.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail