Development Of Distribution Infrastructure Of Package Varanasi 1 At Varanasi District Of Puvvnluttar Pradesh Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme= 1 Supply Of Consumer Service Cable 2 Supply Of Armored Service, varanasi-Uttar Pradesh

Purvanchal Vidyut Vitaran Nigam Limited has published Development Of Distribution Infrastructure Of Package Varanasi 1 At Varanasi District Of Puvvnluttar Pradesh Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme= 1 Supply Of Consumer Service Cable 2 Supply Of Armored Service. Submission Date for this Tender is 03-06-2022. Crushers Breakers and Grinders Tenders in varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32319297
Development Of Distribution Infrastructure Of Package Varanasi 1 At Varanasi District Of Puvvnluttar Pradesh Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme= 1 Supply Of Consumer Service Cable 2 Supply Of Armored Service
Open Tender
Indian
Uttar Pradesh
varanasi
03-06-2022

Tender Details

Development Of Distribution Infrastructure Of Package Varanasi 1 At Varanasi District Of Puvvnluttar Pradesh Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme= 1 Supply Of Consumer Service Cable 2 Supply Of Armored Service Cable For Consumer Service Connection With Accessories As Per Technical Specifications, Scope Of Works And Approved Drawings 3 Supply Of Single Phase Armored Al Cable Size 2Cx 6 Sq Mm 4 Supply Of Three Phase Armored Al Cable Size 4Cx 16 Sq Mm 5 Supply Of 10 Swg Gi Wire 6 Supply Of 8 Swg Gi Wire 7 Conversion Of Existing Lt Lines On Bare Conductor To Areal Bunch Xlpe Cable 8 Conversion Of Existing Lt Lines With Bare Conductor To Ab Xlpe Cable Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 9 Supply Of 8.5 M / 180 Kgs Pcc Poles ( Pcc Pole As Per State Practice ) 10 Galvanized Stay Set For Lt Line With Anchor Plate ( 200X200x6mm ) , 50X8mm Stay Clamp, Stay Guy Insulator, Nut Bolts, 1 Nos Turn Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 11 Conversion Of Existing Lt Lines Using New Earthing As Per Approved Drawings, Technical Specifications And Scope Of Work 12 Supply Of Spike Earthing Made Of 20Mm X 2500 Mm Gi Solid Rod 13 Supply Of 8 Swg Gi Wire For Earthing And Guarding 14 Supply Of Following Lt Ab Xlpe Cable For Conversion Of Existing Lt Bare Conductor Line With Ab Xlpe Cable As Required As Per Technical Specification, Approved Drawings And Scope Of Work: 15 Supply Of Aerial Bunchedxlpe Cable 3 X 50 Sqmm+1X35 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 16 Supply Of Aerial Bunchedxlpe Cable 3 X 70 Sqmm.+1X50 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 17 Supply Of Aerial Bunchedxlpe Cable 3 X 95 Sqmm.+1X70 Sqmm. ( Bare Messenger Wire ) + 1X16 Sqmm. 18 Supply Of Aerial Bunchedxlpe Cable 3 X 120 Sqmm. + 1X95 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 19 Supply Of Pole Mounted Lt Distribution Box As Per Approved Drawings, Technical Specifications And Scope Of Work 20 Supply Of Three Phase Smc Distribution Box With Clamps 21 Supply Of Single Phase Smc Distribution Box With Clamps 22 Supply Of Xlpe Insulated Al. Cable For Energisation Of Distribution Box / Kiosk As Per Approved Drawings, Technical Specifications And Scope Of Work 23 Supply Of 1X25 Mm2 Xlpe Insulated Al.Cable 24 Supply Of Stone Pad ( 300X300x75 ) 25 Supply Of Accessories For Ab Xlpe Cable As Per Approved Drawings, Technical Specifications And Scope Of Work 26 Stainless Steel Strap 27 Hdg Lt Pole Clamp With Nut & Bolt For Laying Abc 28 Dead End Clamp With I-Hook ( Insulated ) 29 Suspension Clamp With I-Hook ( Insulated ) 30 95 / 35 Sqmm - 70 / 25 Sqmm Pg Clamps ( For Line To Line Jumpering & Energizing Db Neutral ) 31 120 / 50 Sqmm - 95 / 25 Sqmm Pg Clamps ( For Line To Line Jumpering & Energizing Db Neutral ) 32 Lt Insulation Piercing Connector 120-50 Sqmm - 50-25 Sqmm Size ( For Energizing Distribution Box ) 33 Lt Insulation Piercing Connector 120-50 Sqmm - 120-50 Sqmm Size ( For Line To Line Jumpering ) 34 Lt Insulation Piercing Connector 16 - 25Sqmmsize Suitable For Street Light Connection 35 Pre-Insulated Compression Connectors Size 16 Sqmm Suitable For Ab Xlpe Cable 36 Pre-Insulated Compression Connectors Size 50 Sqmm Suitable For Ab Xlpe Cable 37 Pre-Insulated Compression Connectors Size 70 Sqmm Suitable For Ab Xlpe Cable 38 Pre-Insulated Compression Connectors Size 95 Sqmm Suitable For Ab Xlpe Cable 39 Pre-Insulated Compression Connectors Size 120 Sqmm Suitable For Ab Xlpe Cable 40 Heat Shrinkable Type End Cap For Ab Xlpe Cable 41 Supply Of New 11 Kv Lines : Feeder Segregation ( Agriculture Feeder ) 42 Supply Of Support For 11 Kv Overhead Line As Per Technical Specification, Approved Drawings And Scope Of Work 43 Supply Of 8.5M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 44 Supply For 3 Phase 11 Kv Line Using New Pre-Fabricated Hot Dip Galvanized Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Ms Angle, Ms Transformer Base Channel, Ms Flats Pole Extension Canal With Welded Plate, Anti Climbing Device Clamp Etc Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 45 Supply Of Hot Dip Galvanized Ms Nuts, Bolts With Washers And Turn Buckle For Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 46 Supply Of Pole Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 47 Supply Of 11 Kv Danger Board 48 Supply Of Stone Pad 300X300x75 49 Supply Of Barbed Gi Wire 12 Swg 50 Supply Of Stay Set ( Galvanized ) With 50X8 Mm Stay Clamp, Stay Insulator ( 1 Nos. ) , Anchor Plate ( 200X200x6 ) , Nut Bolts, 1 Nos Turn-Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. 51 Supply Of Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work. 52 Supply Of 11 Kv45 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 53 Supply Of 11 Kv 5 Kn Polymer Pin Insulators 54 Supply Of Earthing Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 55 Supply Of Spike Earthing 20Mm X 2500 Mm Solid Rod 56 Supply Of 8 Swg Gi Wire For Earthing And Guarding 57 Supply Of 6 Swg Gi Wire For Earthing And Guarding 58 Supply Of Acsr Conductors Of Following Sizes With Jointing Sleeves, Binding Materials, Pg Clamps, Bi-Metallic Clamp, Hardware Etc For Overhead Line And Jumpers As Required As Per Technical Specification, Approved Drawings And Scope Of Work 59 Supply Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel 60 Supply Of 11 Kv, 600A, 3-Ph, 3 Pin Type, Vertical Mounting Type, Gang Operated, Ab Switch Along With Support Insulators, Base Channel Down Pipe, Arcing Horns Etc. Complete Asper Technical Specifications, Scope Of Works And Approved Drawings 61 Supply Of 12 Kv 3Ph Indoor Type Switch Gear And 11 Kv Xlpe Cable As Per Technical Specifications, Approved Drawings And Scope Of Works: 62 Supply Of Indoor Type 12 Kv 3 Ph 1250 A Vcb With Control And Protection System For Out Going Feeder Consisting Ofct, A-Meter, Volt-Meter, Relays, Energy Meter ( Tvm ) Dlms Compliant & Accessories Complete As Per Specifications For Feeder Breaker Protection 63 11 Kv 3X 185 Sqmm Xlpe Armored Power Cable, Aluminum Stranded Conductor, Including Their Termination Materials Like Indoor And Outdoor Termination Kit, Glands, Lugs, Tagging, Cable Path Marker Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of The Works. 64 Supply For Augmentation Of Lines 65 Supply For Augmentation Of 33 Kv Line 66 Supply For Augmentation Of 3 Phase 33 Kv Line Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 67 Supply Of 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 68 Supply New Pre-Fabricated Hot Dip Galvanized Steel Item, For Augmentation Of 33 Kv Line, Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Ms Angle ( 65X65x6mm ) , Ms Flats ( 65X8mm ) Anti Climbing Device Clamp Etc Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 69 Supply Of Hot Dip Galvanized Ms Nuts, Bolts With Washers And Turn Buckle For Guarding Etc. As Per Technical Specification, Approved Drawings And Scope Of Work. 70 Supply Of Pole Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 71 Supply Of 33 Kv Danger Board 72 Supply Of Gi Barbed Wire 12 Swg 73 Supply For Augmentation Of 3 Phase 33 Kv Line Replacing Existing Conductor With Following Type Of New Acsr Conductor Including Jointing Sleeves, Binding Material, Aluminum Tape And Helical Preformed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 74 Supply Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog Replacing Existing Racoon Conductor 75 Supply Of 30 / 3.00 + 7 / 3.00 Mm ( 200 Mm² Al. Area ) - Panther Replacing Existing Dog / Racoon Conductor 76 Supply Of 33 Kv Under Ground Cable As Per Technical Specification, Approved Drawings And Scope Of Work. 77 Supply Of 3Cx300 Sqmm 33 Kv Xlpe Armored Cable 78 Supply Of Accessories For 33 Kv3cx300 Sqmm Xlpe Armored Cable ( 2 Nos Including One Spare ) , Like 160Mm Dia Hdpe Pipes For Road Crossing And 150 Mm Dia Gi Pipegrade B For Pole Support Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, Cablepath Markers, Bi Metallic Clamps, 7 / 20 Gi Wireas Per Technical Specification, Approved Drawing And Scope Of Work 79 Supplyof New Insulator And Hardware For Augmentation Of33 Kv Line As Per Technical Specification, Approved Drawings And Scope Of Work 80 Supply Of 33 Kv 70 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 81 Supply Of 33 Kv 10 Kn Polymer Pin Insulators 82 Supply Of New Earthing Arrangement For Augmentation Of33 Kv Line As Per Technical Specifications, Approved Drawings And Scope Of Work. 83 8 Swg Gi Coil 115 Turns ( 1.85 Kg ) 84 Supply Of New Stay Set ( Galvanized ) For 33 Kv Line With 50X8 Mm Stay Clamp, Guy Insulator, Anchor Plate ( 300X300x8mm ) , Nut Bolts, Turn-Buckles, 1.8 M Long, 20 Mm Diameter Solid Gs Stay Rod & 7 / 4.00 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. 85 Supply Of New Gi Wire For Earthing And Guarding For Augmentation Of33 Kv Line As Per Technical Specification, Approved Drawings And Scope Of Work. 86 Supply Of 6 Swg Gi Wire 87 Supply Of 8 Swg Gi Wire 88 Supply Of Conductor Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 89 Supply Of Pg Clamp For Dog To Dog Conductor 90 Supply Of Pg Clamp For Panther To Panther Conductor 91 Supply For Augmentation Of 11 Kv Lines 92 Supply For Augmentation Of 3 Phase 11 Kv Line Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 93 Supply Of 8.5 Meter Long / 180 Kg Pcc Poles ( Pcc Pole As Per State Practice ) 94 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Pre-Fabricated Hot Dip Galvanized Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Ms Angle, Ms Flats Pole Extension Canal With Welded Plate, Anti Climbing Device Clamp Etc Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 95 Supply Of Hot Dip Galvanized Ms Nuts, Bolts With Washers And Turn Buckle For Guarding Etc.As Per Technical Specification, Approved Drawings And Scope Of Work. 96 Supply Of Pole Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 97 Supply Of 11 Kv Danger Board 98 Stone Pad ( 300X300x75mm ) 99 Supply Of Gi Barbed Wire 12 Swg 100 Supply For Augmentation Of 3 Phase 11 Kv Line Replacing Existing Conductor With Following Type Of New Acsr Conductor Including Jointing Sleeves, Binding Material And Helicon Formed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 101 Supply Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel By Replacing Existing Weasel / Squirrel Conductor 102 Supply Of 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit By Replacing Existing Weasel / Squirrel Conductor 103 Supply Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog By Replacing Existing Racoon / Rabbit Conductor 104 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work 105 Supply Of 11 Kv 45 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 106 Supply Of 11 Kv 5 Kn Polymer Pin Insulators 107 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Earthing Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 108 Supply Of Gi Earthing Spike Made Of 20X2500mm Solid Rod 109 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Stay Set ( Galvanized ) With 50X8 Mm Stay Clamp, Guy Insulator, Anchor Plate ( 200X200x6mm ) , Nut Bolts, 1 No Turn-Buckles, 1.8 M Long 16 Mm Diameter Solid Gi Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. 110 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Gi Wire For Earthing And Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 111 Supply Of 6 Swg Gi Wire 112 Supply Of 8 Swg Gi Wire 113 Supply Of Conductor Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 114 Supply Of Pg Clamp For Weasel To Weasel Conductor 115 Supply Of Pg Clamp For Dog To Dog Conductor 116 Supply Of Pg Clamp For Rabbit To Rabbit Conductor 117 Installation Of Dt Capacitor 118 Supply Of Dt Capacitor With Fitting As Per Technical Specification, Approved Drawing And Scope Of Work 119 Supply Of Lt Shunt Capacitor 440 Volt 10 Kvar 3Phase 50Hz Ip65 120 Supply Of Lt Shunt Capacitor 440 Volt 16 Kvar 3Phase 50Hz Ip65 121 Supply Of Lt Shunt Capacitor 440 Volt 25 Kvar 3Phase 50Hz Ip65 122 Supply Of Lt Shunt Capacitor 440 Volt 40 Kvar 3Phase 50Hz Ip65 123 Supply Of Lt Shunt Capacitor 440 Volt 63 Kvar 3Phase 50Hz Ip65 124 Supply Of Lt Shunt Capacitor 440 Volt 100 Kvar 3Phase 50Hz Ip65 125 Erection Part 126 Installation Of Consumer Service Cable 127 Installation Of Armored Consumer Service Cable With Accessories Including Dismantling Of Existing Service Cable As Per Technical Specifications, Scope Of Works And Approved Drawings 128 Installation Of Single Phase Armored Al Cable Size 2Cx 6 Sq Mm 129 Installation Of Three Phase Armored Al Cable Size 4Cx 16 Sq Mm 130 Gi Wire 8 Swg 131 Gi Wire 10 Swg 132 Erection For Conversion Of Existing Lt Lines On Bare Conductor To Aerial Bunch Xlpe Cable 133 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil Of Following Pole As Per Scope Of Work, Approved Drawings And Specifications: 134 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 135 Erection Of Following Types Of Poles For Lt Overhead Line With Stone Pad, Pole Numbering By Paint With Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 136 Erection Of 8.5 M / 180 Kgs Pcc Poles With Base Stone Pad As Required - ( State Practices Of Pcc Pole And Stone Pad To Be Used ) 137 Excavation Of Lt Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 138 Normal Soil 139 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.2 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 140 Removal Of Existing Lt Bare Line Conductor & Fixtures, Depositing To Stores Of Employer And Erection, Testing & Commissioning Of New Areal Bunched Xlpe Cable, Fixing Tension Clamps For Dead End, Suspension Clamps, Clamps For Neutral, Piercing Connectors Type-I & Type-Ii, Pre- Insulated Compression Connectors, 16 Mm Dia Ms Nuts & Bolts, Pole Clamps, Stainless Steel Strap, Single And Three Phase Pole Mounted Distribution Board, Energisation Of Distribution Box Through 1X25 Sqmm Xlpe Cable Fixing End Cap Etc. As Required As Per Technical Specification, Approved Drawings And Scope Of Work: 141 Erection Of Aerial Bunched Xlpe Cable3 X 50 Sqmm +1X35 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 142 Erection Of Aerial Bunched Xlpe Cable 3 X 70 Sqmm +1X50 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 143 Erection Of Aerial Bunched Xlpe Cable 3 X 95 Sqmm +1X70 Sqmm ( Bare Messenger Cum Neutral ) + 1X16 Sqmm 144 Erection Of Aerial Bunched Xlpe Cable 3 X 120 Sqmm+ 1X95 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 145 Erection, Testing & Commissioning Of Earthing By Inserting Gi Earthing Spike Made Of 20Mm Solid Rod As Per Approved Drawings, Scope Of Work And Technical Specifications 146 Erection Of 8 Swg Gi Wire For Earthing By Providing Gi Nut, Bolts & Washers, Turn Buckle Etc As Per Approved Drawings, Scope Of Work And Technical Specifications 147 Erection, Testing And Commissioning Of New 11 Kv Lines: Feeder Segregation ( Agriculture Feeder ) 148 Survey, Route Alignment & Pole Spotting, Preparation Of Survey Report And Uploading In The Web Portal After Approval Of Project Manager 149 Excavation Of Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil For Following Type Pole As Per Scope Of Work, Approved Drawings And Specifications: 150 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 151 Erection Of Following Types Of Poles For 11 Kv Overhead Line By Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Painting With Red Oxide & Aluminumto Stp Poles Inluding Paint, Numberingof Poleby Paint Including Cement Concrete Foundation Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 152 Erection Of 8.5 M / 180 Kgs Pcc Poles With Base Pad Including Cement Concreting, ( State Practices Of Pcc Pole, Stone To Be Used ) 153 Erection, Testing & Commissioning Of Pre-Fabricated Hdg Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures And Ms Nuts, Bolts & Washersas Per Technical Specification, Approved Drawings And Scope Of Work. 154 Earthing Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 155 Erection, Testing & Commissioning Of Spike Earthing 20Mm X 2500Mm Solid Rod 156 Excavation Of Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 157 Normal Soil 158 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator ( 1 Nos. ) And 0.2 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 159 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 160 Erection Of 5 Kn 11 Kv Polymer Pin Insulator 161 Erection Of 45 Kn 11 Kv Polymer Disc Insulator With Strain Hardware 162 Laying Out, Tensioning, Binding Of Conductor And Tightening Of Stays And Stringing, Testing And Commissioning Of Acsrconductor Of Following Sizes Including Jointing Sleeves, Helical Formed Fittings, Jumpering And By Providing & Erecting Pg Clamps Etc As Required As Per Approved Drawings, Scope Of Work And Technical Specifications 163 Stringing Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel 164 Erection, Testing And Commissioning Of Vertical Type 11 Kvab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete Asper Technical Specifications, Scope Of Works And Approved Drawings 165 Erection Of 12 Kv, 1250 A, 25Ka For 3 Seconds, 3-Ph, Indoor Typevacuum Circuit Breaker With Adopter Panel For Out Going Feeder By Leveling, Alignment And Welding On Existing Cable Trench In Control Room. Testing & Commissioning Of Indoor Vcb Panel Including 3 Nos Indoor Type Current Transformer, A-Meter, Volt-Meter, Relay & Accessories Protection As Per Approved Drawings, Technical Specifications And Scope Of The Work.: 166 Laying, Erection, Termination Using Indoor & Outdoor Termination Kit, 11Kv 3X 185 Sqmm Xlpearmored Power Cablesas Per Technical Specifications, Approved Drawings And Scope Of Works. : 167 Erection, Testing & Commissioning Of New Gi Wire For Earthing And Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 168 Erection Of 6 Swg Gi Wire 169 Erection Of 8 Swg Gi Wire 170 Extension Of Control Room Of 33 / 11 Kv Substation To Accommodate Vcb For New 11 Kv Feeders As Per Technical Specification, Approved Drawing And Scope Of Work. 171 Design, Engineering Construction Of Control Room Building Extension 300 Sq Feet Including Cost Ofall Materials, T&P And Labour, Etc. As Per Technical Specification And Approved Drawing As Per Direction Of Employer 172 Shifting Of Following Distribution Transformer Along With Fixture Including Dismantling , Shifting And Erection From One Location To Another Location As Per Approved Survey. 173 Single Phase Transformer 174 Three Phase Transformer 175 Erection For Augmentation Of Lines 176 Erection For Augmentation Of 33 Kv Line 177 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 178 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 179 Erection Of Following Types Of Additional Poles Matching With Existing Line Supports By Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Painting With Red Oxide & Aluminum Including Paint, Pole Numbering Including Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 180 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 181 Excavation Of Stay Pit For 33 Kv Stay In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 182 Normal Soil 183 Erection Of Complete Stay Set With Gi Stay Wire ( 7X4.00 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.3 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 184 Erection, Testing And Commissioning Of 33 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 185 Erection Of 33 Kv 10 Kn Pin Insulator With Gi Pin 186 Erection Of 33 Kv 70 Kn Disc Insulator With Strain Hardware ( Set Of 3, 11 Kv Disc Insulators ) 187 Erection, Testing & Commissioning Of New Pre-Fabricated Hdg Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 188 Dismantling Of Existing Overhead Line Conductor And Fittings, Depositing The Dismantled Material To EmployerS Store And Laying Out & Stringing Of New Acsr Conductor Of Following Sizes By Providing Jointing Sleeves, Binding Wire & Tape & Helical Formed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 189 Stringing Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog Replacing Existing Racoon Conductor 190 Stringing Of 30 / 3.00 + 7 / 3.00 Mm ( 200 Mm² Al. Area ) - Panther Replacing Existing Dog / Racoon Conductor 191 Erection, Testing & Commissioning Of 33 Kvunder Ground Cable By2 Nos ( Including One Spare ) 3Cx300 Sqmm Xlpe Armored Cable, Using 160 Mm Hdpe Pipe At Road Crossing, 150Mm Dia Gi Pipes For Cable Support, Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, Cable Markers, Clamps, Jumpering And 7 / 20 Gi Wire Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of He Work. 192 Erection For Augmentation Of 3 Phase 33 Kv Line Using New Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work 193 Erection Of 33 Kv 70 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 194 Erection Of 33 Kv 10 Kn Polymer Pin Insulators 195 Erection, Testing & Commissioning Of Earthing As Per Technical Specifications, Approved Drawings And Scope Of Work. 196 8 Swg Gi Coil 115 Turns ( 1.85 Kg ) 197 Erection, Testing & Commissioning Of New Gi Wire For Earthing And Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 198 Erection Of 6 Swg Gi Wire 199 Erection Of 8 Swg Gi Wire 200 Erection For Augmentation Of 11 Kv Lines 201 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 202 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 203 Erection Of Following Types Of Poles For 11 Kv Overhead Line By Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Pole Numbering Including Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 204 Erection Of 8.5 M / 180 Kgs Pcc Poles Withbase Stone Pad ( State Practices Of Pcc Pole And Base Plate / Stone To Be Used ) 205 Excavation Of Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 206 Normal Soil 207 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.2 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 208 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 209 Erection Of 11 Kv Pin Insulator With Gi Pin 210 Erection Of 11 Kv Disc Insulator With Strain Hardware 211 Dismantling Of Existing Overhead Line Conductor & Fittings And Depositing To EmployerS Store, Laying Out, Tensioning, Binding Of New Conductor And Tightening Of Stays And Stringing, Testing And Commissioning Of Acsrconductor Of Following Sizes Including Jointing Sleeves, Helical Formed Fittings, Jumpering And By Providing & Erecting Pg Clamps Etc As Required As Per Approved Drawings, Scope Of Work And Technical Specifications 212 Stringing Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel By Replacing Existing Weasel / Squirrel Conductor 213 Stringing Of 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit By Replacing Existing Weasel / Squirrel Conductor 214 Stringing Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog By Replacing Existing Racoon / Rabbit Conductor 215 Erection, Testing & Commissioning Of Pre-Fabricated Hdg Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures And Hdg Ms Nuts, Bolts & Washers As Per Technical Specification, Approved Drawings And Scope Of Work. 216 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 217 Erection Of 5 Kn 11 Kv Polymer Pin Insulator 218 Erection Of 45 Kn 11 Kv Polymer Disc Insulator With Strain Hardware 219 Earthingand Guarding Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 220 Erection, Testing & Commissioning Of Spike Earthing 20Mm Solid Rod 221 Erection Of 8 Swg Gi Wire For Earthing And Guarding 222 Erection Of 6 Swg Gi Wire For Earthing And Guarding 223 Erection Of Dt Capacitor 224 Erection, Testing & Commissioning Offollowing 440 Volt Lt Shunt Capacitor Including Mounting Structure And Accessories As Required As Per Technical Specifications, Approved Drawings And Scope Of Work. 225 Erection Of Lt Shunt Capacitor 440 Volt 10 Kvar 3Phase 50Hz Ip65 226 Erection Of Lt Shunt Capacitor 440 Volt 16 Kvar 3Phase 50Hz Ip65 227 Erection Of Lt Shunt Capacitor 440 Volt 25 Kvar 3Phase 50Hz Ip65 228 Erection Of Lt Shunt Capacitor 440 Volt 40 Kvar 3Phase 50Hz Ip65 229 Erection Of Lt Shunt Capacitor 440 Volt 40 Kvar 3Phase 50Hz Ip65 230 Erection Of Lt Shunt Capacitor 440 Volt 40 Kvar 3Phase 50Hz Ip65 231 Words

Key Value

Document Fees
INR 29500 /-
EMD
INR 50000000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: DEVELOPMENT OF DISTRIBUTION INFRASTRUCTURE OF PACKAGEVARANASI 1 AT VARANASI DISTRICT OF PuVVNLUTTAR PRADESHUNDERREVAMPED REFORMS-BASED AND RESULTS-LINKED, DISTRIBUTION SECTOR SCHEME
Sl. No. Item Description
1Supply of Consumer Service Cable
2Supply of Armored service cable for consumer service connection with accessories as per technical specifications, scope of works and approved drawings
3Supply of Single Phase armored AL cable size 2CX 6 Sq mm
4Supply of Three Phase armored AL cable size 4CX 16 Sq mm
5Supply of 10 SWG GI wire
6Supply of 8 SWG GI wire
7Conversion of existing LT lines on bare conductor to Areal bunch XLPE cable
8Conversion of existing LT lines with bare conductor to AB XLPE cable using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings
9Supply of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice)
10Galvanized Stay Set for LT line with anchor plate (200x200x6mm), 50x8mm stay clamp, Stay guy insulator, nut bolts, 1 Nos turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work.
11Conversion of existing LT lines using new Earthing as per approved drawings, technical specifications and scope of work
12Supply of Spike Earthing made of 20mm X 2500 mm GI solid Rod
13Supply of 8 SWG GI wire for earthing and guarding
14Supply of following LT AB XLPE Cable for Conversion of existing LT bare conductor line with AB XLPE Cable as required as per technical specification, approved drawings and scope of work:
15Supply of Aerial bunchedXLPE cable 3 X 50 sqmm+1x35 sqmm.(bare messenger wire)+1x16 sqmm.
16Supply of Aerial bunchedXLPE cable 3 X 70 sqmm.+1x50 sqmm.(Bare messenger wire)+1x16 sqmm.
17Supply of Aerial bunchedXLPE cable 3 X 95 sqmm.+1x70 sqmm.( bare messenger wire)+ 1x16 sqmm.
18Supply of Aerial bunchedXLPE cable 3 X 120 sqmm. + 1x95 sqmm.(bare messenger wire) +1x16 sqmm.
19Supply of Pole mounted LT Distribution box as per approved drawings, technical specifications and scope of work
20Supply of Three phase SMC Distribution box with clamps
21Supply of Single phase SMC Distribution box with clamps
22Supply of XLPE insulated Al. cable for energisation of distribution box/ Kiosk as per approved drawings, technical specifications and scope of work
23Supply of 1x25 mm2 XLPE insulated Al.cable
24Supply of Stone pad (300x300x75)
25Supply of Accessories for AB XLPE Cable as per approved drawings, technical specifications and scope of work
26Stainless steel Strap
27HDG LT Pole Clamp with nut & bolt for laying ABC
28Dead end Clamp with I-Hook( Insulated)
29Suspension Clamp with I-Hook ( Insulated)
3095/35 Sqmm - 70/25 sqmm PG Clamps( for line to line jumpering & energizing DB neutral)
31120/50 Sqmm - 95/25 sqmm PG Clamps( for line to line jumpering & energizing DB neutral)
32LT Insulation piercing connector 120-50 sqmm - 50-25 sqmm size (for energizing distribution box)
33LT Insulation piercing connector 120-50 sqmm - 120-50 sqmm size (for line to line jumpering)
34LT Insulation piercing connector 16 - 25sqmmsize suitable for street light connection
35Pre-Insulated Compression connectors size 16 sqmm suitable for AB XLPE cable
36Pre-Insulated Compression connectors size 50 sqmm suitable for AB XLPE cable
37Pre-Insulated Compression connectors size 70 sqmm suitable for AB XLPE cable
38Pre-Insulated Compression connectors size 95 sqmm suitable for AB XLPE cable
39Pre-Insulated Compression connectors size 120 sqmm suitable for AB XLPE cable
40Heat shrinkable type end cap for AB XLPE cable
41Supply of New 11 KV Lines : feeder Segregation ( Agriculture Feeder)
42Supply of Support for 11 KV overhead line as per technical specification, approved drawings and scope of work
43Supply of 8.5m/180 kgs PCC Poles - (PCC Pole as per state practice)
44Supply for 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top clamp, Cross arm, Bracket, Clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS transformer base channel, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
45Supply of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
46Supply of Pole accessories as per technical specification, approved drawing and scope of work
47Supply of 11 KV danger board
48Supply of Stone Pad 300X300X75
49Supply of Barbed GI wire 12 SWG
50Supply of Stay Set (Galvanized) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
51Supply of Insulator and hardware as per technical specification, approved drawings and scope of work.
52Supply of 11 KV45 KN polymer Disc insulator along with suitable hardware fittings
53Supply of 11 KV 5 KN Polymer Pin Insulators
54Supply of Earthing arrangement as per technical specifications,approved drawings and scope of work.
55Supply of Spike Earthing 20mm X 2500 mm solid Rod
56Supply of 8 SWG GI wire for earthing and guarding
57Supply of 6 SWG GI wire for earthing and guarding
58Supply of ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work
59Supply of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel
60Supply of 11 kV, 600A,3-ph, 3 Pin type, Vertical Mounting type, Gang Operated,AB Switch along with Support Insulators, Base Channel down Pipe, Arcing Horns etc. complete asper technical specifications, scope of works and approved drawings
61Supply of 12 KV 3ph Indoor type switch gear and 11 KV XLPE cable as per technical specifications, approved drawings and scope of works:
62Supply of Indoor type 12 KV 3 Ph 1250 A VCB with control and protection system for out going feeder consisting ofCT, A-meter, volt-meter, Relays, energy meter (TVM) DLMS compliant & accessories complete as per specifications for feeder breaker protection
6311 KV 3X 185 sqmm XLPE armored Power cable, aluminum stranded conductor, including their termination materials like indoor and outdoor termination kit, glands, lugs, tagging, cable path marker etc as required as per technical specifications, approved drawings and scope of the works.
64Supply for Augmentation of lines
65Supply for Augmentation of 33 KV Line
66Supply for Augmentation of 3 phase 33 kV line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings
67Supply of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
68Supply New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
69Supply of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding etc. as per technical specification, approved drawings and scope of work.
70Supply of Pole accessories as per technical specification, approved drawing and scope of work
71Supply of 33 KV danger board
72Supply of GI Barbed wire 12 SWG
73Supply for Augmentation of 3 phase 33 kV line replacing existing conductor with following type of new ACSR conductor including jointing sleeves, binding material, aluminum tape and helical Preformed fittings etc as required as per technical specification, approved drawings and scope of work.
74Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog replacing existing racoon conductor
75Supply of 30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther replacing existing dog/racoon conductor
76Supply of 33 KV Under ground cable as per technical specification, approved drawings and scope of work.
77Supply of 3CX300 Sqmm 33 KV XLPE Armored Cable
78Supply of Accessories for 33 KV3Cx300 Sqmm XLPE Armored Cable (2 Nos including one spare),like 160mm dia HDPE pipes for road crossing and 150 mm dia GI pipegrade B for pole support outdoor heat shrinkable cable jointing kits, Lugs,CablePath markers, bi metallic clamps, 7/20 GI wireas per technical specification, approved drawing and scope of work
79Supplyof new Insulator and hardware for Augmentation of33 kV line as per technical specification, approved drawings and scope of work
80Supply of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings
81Supply of 33 KV 10 KN Polymer Pin Insulators
82Supply of new Earthing arrangement for Augmentation of33 kV line as per technical specifications,approved drawings and scope of work.
838 SWG GI Coil 115 turns (1.85 kg)
84Supply of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, guy insulator, anchor plate (300x300x8mm) , nut bolts, turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
85Supply of new GI wire for earthing and guarding for Augmentation of33 kV line as per technical specification, approved drawings and scope of work.
86Supply of 6 SWG GI wire
87Supply of 8 SWG GI wire
88Supply of Conductor accessories as per technical specification, approved drawing and scope of work
89Supply of PG Clamp for Dog to Dog conductor
90Supply of PG Clamp for Panther to Panther conductor
91Supply for Augmentation of 11 KV lines
92Supply for Augmentation of 3 phase 11 kV line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings
93Supply of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice)
94Supply for Augmentation of 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
95Supply of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding etc.as per technical specification, approved drawings and scope of work.
96Supply of Pole accessories as per technical specification, approved drawing and scope of work
97Supply of 11 KV danger board
98Stone Pad(300x300x75mm)
99Supply of GI Barbed wire 12 SWG
100Supply for Augmentation of 3 phase 11 kV line replacing existing conductor with following type of new ACSR conductor including jointing sleeves, binding material and helicon formed fittings etc as required as per technical specification, approved drawings and scope of work.
101Supply of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel by replacing existing weasel/squirrel conductor
102Supply of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit by replacing existing weasel/squirrel conductor
103Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit conductor
104Supply for Augmentation of 3 phase 11 kV line using new Insulator and hardware as per technical specification, approved drawings and scope of work
105Supply of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings
106Supply of 11 KV 5 KN Polymer Pin Insulators
107Supply for Augmentation of 3 phase 11 kV line using new Earthing arrangement as per technical specifications,approved drawings and scope of work.
108Supply of GI Earthing spike made of 20x2500mm solid Rod
109Supply for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 No turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
110Supply for Augmentation of 3 phase 11 kV line using new GI wire for earthing and guarding as per technical specification, approved drawings and scope of work.
111Supply of 6 SWG GI wire
112Supply of 8 SWG GI wire
113Supply of Conductor accessories as per technical specification, approved drawing and scope of work
114Supply of PG Clamp for Weasel to Weasel conductor
115Supply of PG Clamp for Dog to Dog conductor
116Supply of PG Clamp for Rabbit to Rabbit conductor
117Installation of DT Capacitor
118Supply of DT Capacitor with Fitting as per Technical Specification, Approved Drawing and scope of work
119Supply of LT Shunt capacitor 440 Volt 10 KVAr 3Phase 50Hz IP65
120Supply of LT Shunt capacitor 440 Volt 16 KVAr 3Phase 50Hz IP65
121Supply of LT Shunt capacitor 440 Volt 25 KVAr 3Phase 50Hz IP65
122Supply of LT Shunt capacitor 440 Volt 40 KVAr 3Phase 50Hz IP65
123Supply of LT Shunt capacitor 440 Volt 63 KVAr 3Phase 50Hz IP65
124Supply of LT Shunt capacitor 440 Volt 100 KVAr 3Phase 50Hz IP65
125Erection Part
126Installation of Consumer Service Cable
127Installation of Armored consumer service cable with accessories including dismantling of existing service cable as per technical specifications, scope of works and approved drawings
128Installation of Single Phase armored AL cable size 2CX 6 Sq mm
129Installation of Three Phase armored AL cable size 4CX 16 Sq mm
130GI Wire 8 SWG
131GI Wire 10 SWG
132Erection for Conversion of existing LT lines on bare conductor to Aerial bunch XLPE cable
133Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil of following pole as per scope of work, approved drawings and specifications:
1348.5 m/180 kgs PCC Poles - (PCC Pole as per state practice)
135Erection of following types of poles for LT overhead line with Stone pad, pole numbering by paint with cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications:
136Erection of 8.5 m/180 Kgs PCC Poles with base stone Pad as required - (state practices of PCC pole and stone Pad to be used)
137Excavation of LT stay pit in following type of soils,as per scope of work, approved drawings and specifications:
138Normal soil
139Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
140Removal of existing LT bare line conductor & fixtures, depositing to stores of employer and erection, testing & commissioning of new areal bunched XLPE cable, Fixing tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type-I & type-II, Pre- insulated compression connectors, 16 mm dia MS nuts & bolts, pole clamps, stainless steel strap, Single and three phase pole mounted distribution board, energisation of distribution box through 1x25 sqmm XLPE cable fixing end cap etc. as required as per technical specification, approved drawings and scope of work:
141Erection of Aerial Bunched XLPE Cable3 X 50 sqmm +1x35 sqmm ( bare messenger cum neutral ) +1x16 sqmm
142Erection of Aerial Bunched XLPE Cable 3 X 70 sqmm +1x50 sqmm ( bare messenger cum neutral )+1x16 sqmm
143Erection of Aerial Bunched XLPE Cable 3 X 95 sqmm +1x70 sqmm ( bare messenger cum neutral )+ 1x16 sqmm
144Erection of Aerial Bunched XLPE Cable 3 X 120 sqmm+ 1x95 sqmm ( bare messenger cum neutral ) +1x16 sqmm
145Erection, testing & commissioning of earthing by inserting GI Earthing spike made of 20mm solid Rod as per approved drawings, scope of work and technical specifications
146Erection of 8 SWG GI wire for earthing by providing GI nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications
147Erection, testing and Commissioning of New 11 KV lines: Feeder Segregation (Agriculture Feeder)
148Survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of Project Manager
149Excavation of pole pit (of depth 1/6th of pole length) in normal soil for following type pole as per scope of work, approved drawings and specifications:
1508.5 m/180 kgs PCC Poles - (PCC Pole as per state practice)
151Erection of following types of poles for 11 KV overhead line by installing danger plate, anti-climbing devices (barbed wire), Painting with red oxide & aluminumto STP poles inluding paint, numberingof poleby paint including cement concrete foundation using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4)etc as per scope of work, approved drawings and specifications:
152Erection of 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used)
153Erection, testing & commissioning of pre-fabricated HDG steel items like V cross arm, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures and MS nuts, bolts & washersas per technical specification, approved drawings and scope of work.
154Earthing arrangement as per technical specifications,approved drawings and scope of work.
155Erection, testing & commissioning of Spike Earthing 20mm x 2500mm solid Rod
156Excavation of stay pit in following type of soils,as per scope of work, approved drawings and specifications:
157Normal soil
158Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 Nos.) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
159Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.
160Erection of 5 KN 11 kV Polymer Pin insulator
161Erection of 45 KN 11 kV Polymer Disc insulator with strain hardware
162Laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of ACSRConductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications
163Stringing of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel
164Erection, Testing and Commissioning of vertical type 11 kVAB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete asper technical specifications, scope of works and approved drawings
165Erection of 12 kV, 1250 A, 25kA for 3 seconds, 3-ph, indoor typeVacuum Circuit breaker with adopter panel for out going feeder by leveling, alignment and welding on existing cable trench in control room. Testing & commissioning of indoor VCB panel including 3 Nos indoor type Current Transformer,A-meter, volt-meter, Relay & accessories protection as per approved drawings, technical specifications and scope of the work.:
166Laying, erection, termination using indoor & outdoor termination kit, 11KV 3x 185 sqmm XLPEarmored Power cablesas per technical specifications, approved drawings and scope of works. :
167Erection, testing & commissioning of new GI wire for earthing and guarding as per technical specification, approved drawings and scope of work.
168Erection of 6 SWG GI wire
169Erection of 8 SWG GI wire
170Extension of Control room of 33/11 KV Substation to accommodate VCB for new 11 KV feeders as per technical specification, approved drawing and scope of work.
171Design, Engineering construction of Control room building extension 300 Sq feet including cost ofall materials, T&P and Labour,etc. as per Technical specification and approved drawing as per direction of Employer
172Shifting of following Distribution Transformer along with fixture including dismantling , shifting and erection from one location to another location as per approved survey.
173Single Phase Transformer
174Three Phase Transformer
175Erection for Augmentation of lines
176Erection for Augmentation of 33 KV Line
177Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil as per scope of work, approved drawings and specifications:
17811 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
179Erection of following types of additional poles matching with existing line supports by installing danger plate, anti-climbing devices (barbed wire), Painting with red oxide & aluminum including paint, pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications:
18011 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
181Excavation of stay pit for 33 KV Stay in following type of soils,as per scope of work, approved drawings and specifications:
182Normal soil
183Erection of complete stay set with GI stay wire (7x4.00 mm dia), binding of stay wire, by providing Guy stay insulator and 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
184Erection, testing and commissioning of 33 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.
185Erection of 33 kV 10 KN Pin insulator with GI pin
186Erection of 33 kV 70 KN Disc insulator with strain hardware (set of 3, 11 KV disc insulators)
187Erection, testing & commissioning of new Pre-fabricated HDG steel items like V cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures as per technical specification, approved drawings and scope of work.
188Dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employer"s store and laying out & stringing of new ACSR conductor of following sizes by providing jointing sleeves, binding wire & tape & helical formed fittings etc as required as per technical specification, approved drawings and scope of work.
189Stringing of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog replacing existing racoon conductor
190Stringing of 30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther replacing existing dog/racoon conductor
191Erection, testing & commissioning of 33 KVunder ground Cable by2 Nos (including one spare) 3Cx300 Sqmm XLPE Armored Cable, using 160 mm HDPE pipe at road crossing, 150mm dia GI pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, cable markers, clamps, jumpering and 7/20 GI wire etc as required as per technical specifications, approved drawings and scope of he work.
192Erection for Augmentation of 3 phase 33 kV line using new Insulator and hardware as per technical specification, approved drawings and scope of work
193Erection of 33 KV 70 KN polymer Disc insulator along with suitable hardware fittings
194Erection of 33 KV 10 KN Polymer Pin Insulators
195Erection, testing & commissioning of earthing as per technical specifications,approved drawings and scope of work.
1968 SWG GI Coil 115 turns (1.85 kg)
197Erection, testing & commissioning of new GI wire for earthing and guarding as per technical specification, approved drawings and scope of work.
198Erection of 6 SWG GI wire
199Erection of 8 SWG GI wire
200Erection for Augmentation of 11 KV lines
201Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil as per scope of work, approved drawings and specifications:
2028.5 m/180 kgs PCC Poles - (PCC Pole as per state practice)
203Erection of following types of poles for 11 KV overhead line by installing danger plate, anti-climbing devices (barbed wire),pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications:
204Erection of 8.5 m/180 Kgs PCC Poles withBase stone pad(state practices of PCC pole and base plate/stone to be used)
205Excavation of stay pit in following type of soils,as per scope of work, approved drawings and specifications:
206Normal soil
207Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
208Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.
209Erection of 11 kV Pin insulator with GI pin
210Erection of 11 kV Disc insulator with strain hardware
211Dismantling of existing overhead line conductor & fittings and depositing to Employer"s store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of ACSRConductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications
212Stringing of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel by replacing existing weasel/squirrel conductor
213Stringing of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit by replacing existing weasel/squirrel conductor
214Stringing of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit conductor
215Erection, testing & commissioning of pre-fabricated HDG steel items like V cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures and HDG MS nuts, bolts & washers as per technical specification, approved drawings and scope of work.
216Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.
217Erection of 5 KN 11 kV Polymer Pin insulator
218Erection of 45 KN 11 kV Polymer Disc insulator with strain hardware
219Earthingand guarding arrangement as per technical specifications,approved drawings and scope of work.
220Erection, testing & commissioning of Spike Earthing 20mm solid Rod
221Erection of 8 SWG GI wire for earthing and guarding
222Erection of 6 SWG GI wire for earthing and guarding
223Erection of DT Capacitor
224Erection, Testing & Commissioning offollowing 440 Volt LT shunt Capacitor including mounting Structure and accessories as required as per technical specifications,approved drawings and scope of work.
225Erection of LT Shunt capacitor 440 Volt 10 KVAr 3Phase 50Hz IP65
226Erection of LT Shunt capacitor 440 Volt 16 KVAr 3Phase 50Hz IP65
227Erection of LT Shunt capacitor 440 Volt 25 KVAr 3Phase 50Hz IP65
228Erection of LT Shunt capacitor 440 Volt 40 KVAr 3Phase 50Hz IP65
229Erection of LT Shunt capacitor 440 Volt 40 KVAr 3Phase 50Hz IP65
230Erection of LT Shunt capacitor 440 Volt 40 KVAr 3Phase 50Hz IP65
231Words