Kanpur Electricity Supply Co Limited-KESCO has published Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme Infrastructure Work Under Loss Reduction In Kesco, Kanpur- 1 Supply Of1.1_Kv Xlpe Insulated Pvc Sheathed Armoured Aluminum Cable In High Loss Area 2 2Cx6 Sqmm 3 2Cx10 Sqmm 4 . Submission Date for this Tender is 26-05-2022. Crushers Breakers and Grinders Tenders in kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supply of1.1_KV XLPE insulated PVC sheathed armoured Aluminum Cable in high loss area |
2 | 2Cx6 sqmm |
3 | 2Cx10 sqmm |
4 | 4Cx16 sqmm |
5 | 4Cx25 Sqmm |
6 | Supply of 9.5 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 37 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) |
7 | Supply of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) |
8 | Supply of New Galvanised Stay Set with anchor plate (200x200x6mm), 50x8mm stay clamp, Stay guy insulator, nut bolts, 2 Nos turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work. |
9 | Supply of Spike Earthing 2540mm longmade of 20mm GI solid Rod. |
10 | Supply of Hot Dip galvanized G.I. Wire Earthing Coil |
11 | Supply of 6 SWG GI wire |
12 | Supply of 8 SWG GI wire |
13 | Supply of AERIAL BUNCHED XLPECABLE 3x95+1x70+1x16 sqmm |
14 | Supply of AERIAL BUNCHED XLPECABLE 3x120+1x70+1x16 sqmm |
15 | Supply of AERIAL BUNCHED XLPECABLE 3x150+1x120+1x16 sqmm |
16 | Supply of LT Pole Clamps with nut & bolts for Laying ABC |
17 | Supply of Dead End clamps with Eye-Hook (Insulated) |
18 | Supply of Suspension clamps with Eye-Hook (Insulated) |
19 | Supply of LT insulation Piercing Connectors of 25-150 sqmm size for energizing distribution Kiosk/box |
20 | Supply of LT insulation Piercing Connectors of 25-120sqmm size for energizing distribution Kiosk/box |
21 | Supply of LT insulation Piercing Connectors of 25-95sqmm size for energizing distribution Kiosk/box |
22 | Supply of L.T. Neutral Bare Connector. |
23 | Supply of 1X25 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk |
24 | Supply of Single Phase Distribution Box with clamps with lug. |
25 | Supply of Three Phase Distribution Box with clamps with lug. |
26 | Supply of Pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, transformer mounting structure etc made of MS Channels (100x50x6mm), MS angle (65x65x6mm), MS flats (65x8mm) of given size duly galvanisedfor over head structures as per technical specification, approved drawings and scope of work. |
27 | Supply ofMS Nuts, Bolts with Washers duly galvanised as per technical specification, approved drawings and scope of work (off size). |
28 | Supply of 11 KV polymer/porcelain Disc insulator 70 KN along with suitable hardware fittings |
29 | Supply of 11 KV Polymer /porcelain Pin Insulators 10 KN with GI PIN |
30 | Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog |
31 | Supply of CI Packing (Galvanised) as per site requirement. |
32 | Supply ofDanger Plate |
33 | Supply ofG.I. Barbed Wire |
34 | Supply of 12 kV, 1600 A, 350MVA, 25kA for 3 seconds, 3-ph, indoor typeVacuum Circuit breaker along with 12 kV, 1-Phase, 400-200/5-5 3 Nos indoor type Current Transformer, indoor mounting type control panel for feeder protection, control cabling between VCB and indoor control panel (SCADA Compatible & 61850 protocol compliant protection relays)and required accessories, bi-metallic clamps, A-meter, volt-meter, 3-phase electronic energy meter, Relay & accessories complete for feeder breaker protection along with adapter panel/complete mechanism to connect with existing busbaras per technical specifications, approved drawings and scope of works (Outgoing Panel) |
35 | Supply of G.I. Pipe 6" dia. with Clamps etc. |
36 | Supply of11KV XLPE 3 phase power cable armored,aluminium conductor,standard as per technical specification,approved drawing and scope of works 3Cx185 sqmm |
37 | Supply of Heat Shrinkable Jointing Kit Outdoor /indoor for 11 KV 3x185 sq. mm XLPE Cable |
38 | Supply of Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable |
39 | Supply of Heat Shrinkable Jointing Kit indoor for 11 KV 3x185 sq. mm XLPE Cable |
40 | Supply of 11KV Straight through Joint 3x185 sqmm XLPE Cable |
41 | Supply of L.T Aluminum armored XLPE single core cable size |
42 | 1X630 Sq mm. |
43 | 1X400 Sq mm. |
44 | Supply of Al Crimping lugs (630/400/) Sq mm. for all cables ofDistribution Transformers (Any rating) |
45 | Supply of 1100 Grade. PVC sheathed steel strip armored, aluminum conductorLT XLPE insulated cable size |
46 | 3.5 CX240 Sq mm. XLPE |
47 | 3.5 CX120 Sq mm. XLPE |
48 | 3.5 CX70 Sq mm. XLPE |
49 | Supply of Cable end termination using total double compersation Brassglands and crimping type aluminum thimbles size for L.T. cables. |
50 | 3.5 CX240 Sq mm. XLPE |
51 | 3.5 CX120 Sq mm. XLPE |
52 | 3.5 CX70 Sq mm. XLPE |
53 | Supply ofHDPE pipe 110 mm dia to be laid by horizontal drilling for under ground piping (trenchless) at road cross of above cable. |
54 | Supply of GI Pipe for external area of small cable to houses |
55 | 50mm dia |
56 | 40 mm dia |
57 | Supply of PVC pipe heavy gauge 40 mm dia (under ground area) pipe for small cable to houses |
58 | Supply of G.I. Strip of size 25x3 sqmm for making connection between Type-B/C Panel and earth rod |
59 | Supply ofType LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubical should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2 mm CRCA Sheet Steel & Provided with 2 mm Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 1000 & 630 KVA (Type A-1) Incomer - 1 No. 1250 Amp. TP MDO ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 4 sets of 400 amp. TP MCCB with spreader & Extended handle) (2 sets of 250amp. TP MCCB with spreader & Extended handle)(2 sets of 100 0amp. TP MCCB with spreader & Extended handle) |
60 | Supply of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubicle should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2 mm CRCA Sheet Steel & Provided with 2 mm Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 400 KVA (Type A-2) (Incomer - 1 set of 800 amp.ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 6 sets of 250 amp. TP MCCB with spreader & Extended handle (5No.+1No. Capacitor panel)) (2 sets of 100 amp. TP MCCB with spreader & Extended handle) |
61 | Supply of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubical should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2 mm CRCA Sheet Steel & Provided with 2 mmHinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 250 KVA (Type A-3) (Incomer - 1 set of 630 amp. ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs)) (Outgoing - 5 sets of 250 amp. TP MCCB with spreader & Extended handle (4No.+1No. Capacitor panel)) (2 sets of 100 amp. TP MCCB with spreader & Extended handle) |
62 | Supply of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubical should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2 mm CRCA Sheet Steel & Provided with 2 mm Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 160 KVA (Type A-4) (Incomer - 1 set of 400 amp. ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 4 sets of 250 amp. TP MCCB with spreader & Extended handle (3No.+1No. Capacitor panel)) (2 sets of 100 amp. TP MCCB with spreader & Extended handle) |
63 | Supply of Outdoor type feeder pillar panel to be made of 2mm. CRCA sheet & covers will be 2 mm CRCA sheet duly powder coated paint including suitable foundation with 400 amp. Aluminum Bus bar(Type B-1) with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM)having : 1 no Incomer 250amp. TP MCCB and 6 No.out-going 100 amp. TP MCCB with spreader & Extended handle. |
64 | Supply of Outdoor type feeder pillar panel to be made of 2mm. CRCA sheet & covers will be 2 mm CRCA sheet duly powder coated paint including suitable foundation with 300 amp. Aluminum Bus bar (Type B-2) with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM)having :1 no Incomer 250amp. TP MCCB and 5 No.out-going 100 amp. TP MCCB spreader & Extended handle. |
65 | Supply of Outdoor type feeder pillar panel to be made of 2mm. CRCA sheet & covers will be 2 mm CRCA sheet duly powder coated paint including suitable foundation with 300 amp. Aluminum Bus bar(Type B-3) with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM)having :1 no Incomer 250 amp. TP MCCB and 4 No.out-going 100amp. TP MCCB spreader & Extended handle. |
66 | Supply of lockable distribution box along withbar lock of size 450x450mm including suitable foundation with bus baramp. 140TPN to feed up to 10 houses (Type C). Panel to be made of 2mm. CRCA sheet |
67 | Supplyof GI pipe of 40 mm dia under ground (For street light) |
68 | Supply junction box on STP/PCC pole with 900 mm long GI pipe 25 mm dia with clamp (for street light connection) |
69 | Supply ofGI Pipe 40mm dia B-Class 40 feet longfor earthing of Type A and B panels |
70 | Supply of G.I . Pipe Chemical Earthing (electrode 3 mtr long 80 mm inner dia along with Chemical powder) |
71 | Supply of G.I.Strip of Size 50X6mmfor connecting the Panels A& B type Panels. |
72 | Supply of M.S Flat of Size 25X3mmfor connecting the Panels C- type Panels. |
73 | Supply of Steel Structure of size 65x65x6 mm (M.S. Angle ) |
74 | Supply of Single phase polycarbonate meter box |
75 | Supply of Three Phase polycarbonate meter box |
76 | Supply of 11 KVCAPACITOR BANK INCLUDING MOUNTING STEEL GALVANISED STRUCTURE AND ACCESSORIES AS REQUIRED AS PER DETAILED TECHNICAL SPECIFICATIONS, DRAWING AND SCOPE OF WORKS IN FOLLOWING ARRANGEMENTS: |
77 | CAPACITOR BANK 1200 KVAR - AUTO TYPE SUBSTATION MOUNTED WITH ALL ASSOCIATED EQUIPMENT LIKE 11 KV VCB ALONG WITH ADAPTER PANEL/COMPLETE MECHANISM FOR CONNECTION WITH EXISTING BUSBAR, C&R PANEL, CTs, 11 KV 200A ISOLATORS WITH EARTH SWITCH, RVT, 11 KV STATION CLASS LA, RED OXIDE / ALUMINIUM PAINTING, 2.5 SQ.MM. PVC ARMOURED STRANDED COPPER CONTROL CABLES, PROTECTION CIRCUIT AND EQUIPMENT, EARTHING, 16 MM DIA MS NUTS & BOLTS ETC AS REQUIRED AS PER APPROVED TECHNICAL SPECIFICATIONS, DRAWING AND SCOPE OF WORKS |
78 | CAPACITOR BANK 1500 KVAR - AUTO TYPE SUBSTATION MOUNTED WITH ALL ASSOCIATED EQUIPMENT LIKE 11 KV VCB ALONG WITH ADAPTER PANEL/COMPLETE MECHANISM FOR CONNECTION WITH EXISTING BUSBAR,, C&R PANEL, CTs, 11 KV 200A ISOLATORS WITH EARTH SWITCH, RVT, 11 KV STATION CLASS LA, RED OXIDE / ALUMINIUM PAINTING, 2.5 SQ.MM. PVC ARMOURED STRANDED COPPER CONTROL CABLES, PROTECTION CIRCUIT AND EQUIPMENT, EARTHING, 16 MM DIA MS NUTS & BOLTS ETC AS REQUIRED AS PER APPROVED TECHNICAL SPECIFICATIONS, DRAWING AND SCOPE OF WORKS |
79 | Supply of 11 kV ACS dog covered conductor with all accessories. |
80 | ERECTION PART |
81 | Armoured Consumer Cabling in High Loss Areas |
82 | Erection/Laying of 1.1_KV XLPE insulated PVC sheathed armoured Aluminum Cablefrom exisitng LT line/pole to Consumer meter including proper lugging. |
83 | 2Cx6 sqmm |
84 | 2Cx10 sqmm |
85 | 4Cx16 sqmm |
86 | 4Cx25 Sqmm |
87 | Replacement of Bare conductors/ Damaged A.B. Cable with AB cables |
88 | Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil as per scope of work, approved drawings and specifications: |
89 | 9.5 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 37 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) |
90 | Excavation of additional pole pit (of depth 1/6th of pole length) in soft rock/ mettalic road/ RCC / khranjaas per scope of work, approved drawings and specifications: |
91 | 9.5 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 37 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) |
92 | Erection of following types of poles for LT overhead line by providing and installingred oxide & aluminium paint, pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) or/and 200 mm average size bolders mixed with excavated earth etc as per scope of work, approved drawings and specifications: |
93 | 9.5 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 37 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) cement concreting 0.5 cmt |
94 | Excavation of stay pit in following type of soils,as per scope of work, approved drawings and specifications: |
95 | Normal soil |
96 | Soft rock soil/soft rock/ mettalic road/ RCC / kharanja |
97 | Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works. |
98 | Dismantling/Removal of existing LT bare conductor line or damaged A.B. cable & fixtures including damaged poles, depositing to stores of employer and erection, testing & commissioning of new aerial bunched XLPE cable,tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type-I & type-II, 16 mm dia MS nuts & bolts, pole clamps, etc. as required as per technical specification, approved drawings and scope of work: |
99 | Erection of AERIAL BUNCHED XLPECABLE 3x95+1x70+1x16 sqmm with all assecessiories. |
100 | Erection of AERIAL BUNCHED XLPECABLE 3x120+1x70+1x16 sqmm with all assecessiories. |
101 | Erection of AERIAL BUNCHED XLPECABLE 3x150+1x120+1x16 sqmm with all assecessiories. |
102 | Erection of Single Phase Distribution Box with clamps, Lug and all accessories. |
103 | Erection of Three Phase Distribution Box with clamps Lug and all accessories. |
104 | Erection, testing & commissioning of earthing by inserting GI Earthing spike 2540 mm long made of 20mm solid Rod as per approved drawings, scope of work and technical specifications |
105 | Erection, testing & commissioning of earthing coil |
106 | Erection of 6 SWG GI wire for earthing by providing GI nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications |
107 | Shifting of Existing consumer connection from existing bare conductor line/damaged A.B. cable line to newly erected AB Cable line |
108 | Single Phase Connection |
109 | Three Phase Connection |
110 | Strengthening of existing damaged pole by providing and welding 1.2mtr long 3 No MS angle 65*65*6mm and carrying out required grouting and pole plinth activities as per approved drawing and technical specification. |
111 | 11 KV Feeder Bifurcation by constructing 11 KV Over Head Line |
112 | Survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of Project Manager |
113 | Excavation of pole pit (of depth 1/6th of pole length) in normal soil as per scope of work, approved drawings and specifications: |
114 | 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) |
115 | 9.5 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 37 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) |
116 | Excavation of pole pit (of depth 1/6th of pole length) in soft rock/ metallic road/ RCC / kharanjaas per scope of work, approved drawings and specifications: |
117 | 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) |
118 | 9.5 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 37 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) |
119 | Erection of following types of poles for 11 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire), earthing material (coil and 8SWG GI wire), red oxide & aluminium paint, pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) or/and 200 mm average size bolders mixed with excavated earth etc as per scope of work, approved drawings and specifications: |
120 | 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) cement concreting 0.65 cmt |
121 | 9.5 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 37 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) cement concreting 0.5 cmt |
122 | Erection, testing & commissioning of pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures and MS nuts, bolts & washers all (galvanized)including painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work. |
123 | Earthing arrangement as per technical specificatons,approved drawings and scope of work. |
124 | Excavation, erection, testing & commissioning of Spike Earthing of 2540 mm long with 20mm solid Rod |
125 | Excavation, erection, testing & commissioning of Earthing Coil |
126 | Erection of 8 SWG GI wire for earthing and guarding by providing GI nut, bolts & washers, turn buckle etc |
127 | Erection of 6 SWG GI wire for earthing and guarding by providing GI nut, bolts & washers, turn buckle etc |
128 | Excavation of stay pit in following type of soils,as per scope of work, approved drawings and specifications: |
129 | Normal soil |
130 | Soft soil/soft rock/ metallic road/ RCC / khranja |
131 | Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works. |
132 | Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work. |
133 | 11 kV Pin insulator with GI pin |
134 | 11 kV Disc insulator 70KN with strain hardware |
135 | Laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of ACSRConductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications |
136 | 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog |
137 | Erection of 12 kV, 1600 A, 350MVA, 25kA for 3 seconds, 3-ph, indoor typeVacuum Circuit breaker along with 12 kV, 1-Phase, 400-200/5-5 3 Nos indoor type Current Transformer, indoor mounting type control panel for feeder protection, control cabling between VCB and indoor control panel (SCADA Compatible & 61850 protocol compliant protection relays)and required accessories, bi-metallic clamps, A-meter, volt-meter, 3-phase electronic energy meter, Relay & accessories complete for feeder breaker protection along with adapter panel/complete mechanism to connect with existing busbaras per technical specifications, approved drawings and scope of works . |
138 | 11 KV Feeder Bifurcation by laying Under Ground Cable |
139 | Survey, route alignment & pole spotting and detection of existing electrical/telephonic cable/and other utilites of public utilites departments with the help of utilitiy dectector andpreparation of survey report and uploading in the web portal after approval of Project Manager. |
140 | Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil as per scope of work, approved drawings and specifications: |
141 | 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) |
142 | Excavation of additional pole pit (of depth 1/6th of pole length) in soft rock/soft rock/ mettalic road/ RCC / khranjaas per scope of work, approved drawings and specifications: |
143 | 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) |
144 | Erection of following types of poles for 11 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire), earthing material (coil and 8SWG GI wire), red oxide & aluminium paint, pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) or/and 200 mm average size bolders mixed with excavated earth etc as per scope of work, approved drawings and specifications: |
145 | 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) cement concreting 0.65 cmt |
146 | Excavation of stay pit in following type of soils,as per scope of work, approved drawings and specifications: |
147 | Normal soil |
148 | Soft rock soil/soft rock/ mettalic road/ RCC / khranja |
149 | Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works. |
150 | Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work. |
151 | 11 kV Pin insulator with GI pin |
152 | 11 kV Disc insulator 70KN with strain hardware |
153 | Erection, testing & commissioning of pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures and MS nuts, bolts & washers including painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work. |
154 | Earthing arrangement as per technical specificatons,approved drawings and scope of work. |
155 | Excavation, erection, testing & commissioning of Spike Earthing of2540 mm long with 20mm solid Rod |
156 | Excavation, erection, testing & commissioning of Earthing Coil |
157 | Erection of 8 SWG GI wire for earthing and guarding by providing GI nut, bolts & washers, turn buckle etc |
158 | Laying of 11kV cable through HDD method (including cable length mounted upto pole top minus cable length laid inside G.I. Pipe)including digging of pit |
159 | Digging of Trench .6 mtr wide .9 mtr to 1.5 mtr deep for laying of Pipe and Cable |
160 | NORMAL SOIL |
161 | SOFT ROCK /kharanja |
162 | HARD ROCK/metallic road/RCC |
163 | Laying of GI Pipe 6" dia in above digged trench and also for raising Cable on double Pole/Structure Laying of 11 KV Cable 3x185 sqmm |
164 | Laying of 11 kv Cable through above Pipe |
165 | Laying of Cable in above digged trench and also mounting Upto line by using bricks/ sand &stone pad as per REC norms |
166 | Making andMounting of heat shrinkable jointing kit outdoor/ indoor for 11 KV 3x185 sqmm XLPE Cable |
167 | Digging suitable Pit and making straight through and joint 11 KV 3x185 sqmm |
168 | Making of Straight Through joint and Construction of RB Pit 3x1x1 mtr. with 9 inch thick side wall and 6 inch thick RCC bed along with RCC Trench Cover in Three Parts duly plastered and finsihed for housing St. through joint. box and filled with sand. |
169 | Road restoration Charges against thepermission from concerning department like nagar nigam, pwd, NHAI etc |
170 | NORMAL SOIL |
171 | SOFT ROCK /khranja |
172 | HARD ROCK/metallic road/RCC |
173 | Erection of 12 kV, 1600 A, 350MVA, 25kA for 3 seconds, 3-ph, indoor typeVacuum Circuit breaker along with 12 kV, 1-Phase, 400-200/5-5 3 Nos indoor type Current Transformer, indoor mounting type control panel for feeder protection, control cabling between VCB and indoor control panel (SCADA Compatible & 61850 protocol compliant protection relays)and required accessories, bi-metallic clamps, A-meter, volt-meter, 3-phase electronic energy meter, Relay & accessories complete for feeder breaker protection along with adapter panel/complete mechanism to connect with existing busbaras per technical specifications, approved drawings and scope of works . |
174 | Conversion of Exisiting LT Bare Conductor Line into LT Under Ground Network. |
175 | Erection ofL.T Aluminum armored XLPE single core cable |
176 | Installation of L.T Aluminum armored XLPE single core cable size 1X630 Sq mm. |
177 | Installation of L.T Aluminum armored XLPE single core cable size 1X400 Sq mm. |
178 | Al Crimping lugs (630/400/240/120/70) Sq mm. |
179 | Erectionof Cable end termination using total double compersation Brassglands and crimping type aluminum thimbles size |
180 | 3.5 CX240 Sq mm. XLPE |
181 | 3.5 CX120 Sq mm. XLPE |
182 | 3.5 CX70 Sq mm. XLPE |
183 | Laying, testing and commissioning of 1100 volts grade, PVC sheathed steel strip armored aluminum conductor LT XLPE Insulated Cable of sizes 3.5 CX70/3.5 CX120/3.5 CX240 Sq mm.to be laid under ground in HDPE Pipes |
184 | Digging of trenchbyMaking pits after due survey with the help of utility detector of existing electrical/telephonic cable/and other utilites of public utilites departmentand laying of cables of size 3.5 CX70/3.5 CX120/3.5 CX240 Sq mm. XLPE by manual drill (by making moles) |
185 | Digging of trenchbyMaking pits after due survey with the help of utility detector of existing electrical/telephonic cable/and other utilites of public utilites departmentand laying of cables of size 3.5 CX70/3.5 CX120/3.5 CX240 Sq mm. XLPE through HDD method with the help of HDD Machine |
186 | Digging of trench by open trench method after due survey with the help of utility dectector of existing /telephonic cable and other utilites of public utilites departmentand laying of cables of size 3.5 CX70/3.5 CX120/3.5 CX240 Sq mm. XLPE |
187 | Back filling and restoring the road to make as original including supply of all material and RoW permission required from the land owner authority(nagar nigam, PWD, NHAI etc) for all L.T. cables, pipe and service cables concerned with a single D.T. |
188 | Laying of HDPE pipe of various sizes by horizontal drilling for under ground piping (trenchless) for above cable at road crossing min. depth of pipe shall be 1.5 mtr. Below surface 110 mm. dia. |
189 | Laying of GI Pipe of 50mm dia (External area) |
190 | Laying of GI Pipe of 40mm dia (External area) |
191 | Laying of PVC pipe heavy gauge 40 mm dia (under ground area) |
192 | Erection of G.I. Strip/M.S. Strip of size 25x3/50x6 sqmm connecting Type A/B/C pannel with spike rod/ chemical earthing/deep bore earthing arrangement including required bolting/welding |
193 | Dismantling of Existing LT overhead line including STP poles, bare conductor/A.B. Cable, pole accessories and transportation of Dismantled materials to KESCO Store. |
194 | Laying of Aluminum armored XLPEs cables size 2X6 Sq mm. upto consumer meter |
195 | Laying of Aluminum armored XLPEs cables size 2X10 Sq mm. upto consumer meter |
196 | Laying of Aluminum armored XLPEs cables size 4X16 Sq mm. upto consumer meter |
197 | Laying of Aluminum armored XLPEs cables size 4X25Sq mm. upto consumer meter |
198 | Installation, Testing & Commissioning of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubical should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2 mm CRCA Sheet Steel & Provided with 2 mmHinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 1000 & 630 KVA (Type A-1) Incomer - 1 No. 1250 Amp. ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 4 sets of 400 amp. TP MCCB with spreader & Extended handle) (2 sets of 250amp. TP MCCB with spreader & Extended handle)(2 sets of 100 0amp. TP MCCB with spreader & Extended handle) |
199 | Installation, Testing & Commissioning of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubicle should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2mmCRCA Sheet Steel & Provided with 2 mm Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 400 KVA (Type A-2) (Incomer - 1 set of 800 amp.ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 6 sets of 250 amp. TP MCCB with spreader & Extended handle (5No.+1No. Capacitor panel)) (2 sets of 100 amp. TP MCCB with spreader & Extended handle) |
200 | Installation, Testing & Commissioning of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubical should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2mm Sheet Steel & Provided with2mmHinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 250 KVA (Type A-3) (Incomer - 1 set of 630 amp. ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs)) (Outgoing - 5 sets of 250 amp. TP MCCB with spreader & Extended handle (4No.+1No. Capacitor panel)) (2 sets of 100 amp. TP MCCB with spreader & Extended handle) |
201 | Installation, Testing & Commissioning of Outdoor Type LT Distribution Box with a rupturing capacity of 50 KA at 415 volt Called for Individual items (CPRI approved manufacturer) Openable in front & back suitable for 3 Phase, four wire, 50 Hz AC Supply & an ambient temperature of 45 deg. C. The Cubical should be weather proof, Dust proof, Bremen proof and in closer protection shall be IP-65 as per IS 2147- 1962 and IS-8623 the panels & switches boards shall be fabricated out of 2 mm CRCA Sheet Steel & Provided with 2 mm Hinged door Including suitable Foundation, MAIN LT PANEL AT SUBSTATION- 160 KVA (Type A-4) (Incomer - 1 set of 400 amp. ACB with inbuilt MPR Released with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM) with control MCBs) (Outgoing - 4 sets of 250 amp. TP MCCB with spreader & Extended handle (3No.+1No. Capacitor panel)) (2 sets of 100 amp. TP MCCB with spreader & Extended handle) |
202 | Installation, Testing & Commissioning of Outdoor type feeder pillar panel to be made of 2mm. CRCA sheet & covers will be 2 mm CRCA sheet duly powder coated paint including suitable foundation with 400 amp. Aluminum Bus bar(Type B-1) with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM)having : 1 no Incomer 250amp. TP MCCB and 6 No.out-going 100 amp. TP MCCB with spreader & Extended handle. |
203 | Installation, Testing & Commissioning of Outdoor type feeder pillar panel to be made of 2mm. CRCA sheet & covers will be 2 mm CRCA sheet duly powder coated paint including suitable foundation with 300 amp. Aluminum Bus bar (Type B-2) with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM)having :1 no Incomer 250amp. TP MCCB and 5 No.out-going 100 amp. TP MCCB spreader & Extended handle. |
204 | Installation, Testing & Commissioning of Outdoor type feeder pillar panel to be made of 2mm. CRCA sheet & covers will be 2 mm CRCA sheet duly powder coated paint including suitable foundation with 300 amp. Aluminum Bus bar(Type B-3) with (On/Off Indicating light) (Metering on Incomer- 1 set of Digital Ammeter with ASS) (1 set of Digital Voltmeter with VSS) (1 set of LED type Phase Indication light (22.5 MM)having :1 no Incomer 250 amp. TP MCCB and 4 No.out-going 100amp. TP MCCB spreader & Extended handle. |
205 | Installation, Testing & commissioning of lockable distribution box along with bar lock of size 450x450 mm including suitable foundation with bus bar 140 amp. TPN to feed up to 10 houses (Type C).Panel to be made of 2mm. CRCA sheet |
206 | Installation of2x10 sq mm. XLPE cable (for street light) |
207 | Installation and laying of GI pipe of 40 mm dia under ground (For street light) |
208 | Installation of junction box on STP/PCC pole with 900 mm long GI pipe 25 mm dia with clamp (for street light connection) |
209 | Boring upto 39 feet and erection of GI Pipe 40mm dia B-Class 40 feet long for connection with Type-A and B panel along with supply of G.I. Strip of size 50x6 sqmm |
210 | Erection/Pegging of M.S.EARTH spike ROD 2540X20 MM |
211 | Erection of G.I. Pipe chemical earthing electrode 3 mtr long 80 mm inner dia along with Chemical powder |
212 | Preparation and submission of 2 sets of detailed printed drawing/auto cad drawing / PDF (along with digital copy) of L.T. network of each D.T. depicting location of L.T. cables and all panels(Type-A,B and C) and separate list for all connections on Type C panels in excel format |
213 | Erection of Single phase poly carbonate meter box after removal of existing meter box and connections of meters with armoured cable laid along with resealing of meter with seals provided by Kesco |
214 | Erection of Three phase poly carbonate meter box after removal of existing meter box and connections of meters with armoured cable laid along with resealing of meter with seals provided by Kesco |
215 | Reconductoring of 11 kV OH line. |
216 | Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil as per scope of work, approved drawings and specifications: |
217 | 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) |
218 | Excavation of additional pole pit (of depth 1/6th of pole length) in soft rock/soft rock/ mettalic road/ RCC / khranjaas per scope of work, approved drawings and specifications: |
219 | 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) |
220 | Erection of following types of poles for 11 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire), earthing material (coil and 8SWG GI wire), red oxide & aluminium paint, pole numbering excluding cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) or/and 200 mm average size bolders mixed with excavated earth etc as per scope of work, approved drawings and specifications: |
221 | 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) cement concreting 0.65 cmt |
222 | Excavation of stay pit in following type of soils,as per scope of work, approved drawings and specifications: |
223 | Normal soil |
224 | Soft rock soil/soft rock/ mettalic road/ RCC / khranja |
225 | Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works. |
226 | Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work. |
227 | 11 kV Pin insulator with GI pin |
228 | 11 kV 70KN Disc insulator with strain hardware |
229 | Dismantling of existing overhead line conductor & fittings and depositing to KESCo store, Laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of ACSRConductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications |
230 | 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit condcutor |
231 | Erection, testing & commissioning of pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures and MS nuts, bolts & washers all galvanized including painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work. |
232 | Earthing arrangement as per technical specificatons,approved drawings and scope of work. |
233 | Excavation, erection, testing & commissioning of Spike Earthing of 2540 mm long with 20mm solid Rod |
234 | Excavation, erection, testing & commissioning of Earthing Coil |
235 | Erection of 8 SWG GI wire for earthing and guarding by providing GI nut, bolts & washers, turn buckle etc |
236 | Strengthening of existing damaged pole by providing and welding 1.2mtr long 3 No MS angle 65*65*6mm and carrying out required grouting and pole plinth activities as per approved drawing and technical specification. |
237 | Reconductoring of 11 kV UG line. |
238 | Survey, route alignment & pole spotting and detection of existing electrical/telephonic cable/and other utilites of public utilites departments with the help of utilitiy dectector andpreparation of survey report and uploading in the web portal after approval of Project Manager. |
239 | Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil as per scope of work, approved drawings and specifications: |
240 | 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) |
241 | Excavation of additional pole pit (of depth 1/6th of pole length) in soft rock /soft rock/ mettalic road/ RCC / khranjaas per scope of work, approved drawings and specifications: |
242 | 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) |
243 | Erection of following types of poles for 11 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire), earthing material (coil and 8SWG GI wire), red oxide & aluminium paint, pole numbering excluding cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) or/and 200 mm average size bolders mixed with excavated earth etc as per scope of work, approved drawings and specifications: |
244 | 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) and bottom Galvanized as perIS 2629 (1985) cement concreting 0.65 cmt |
245 | Excavation of stay pit in following type of soils,as per scope of work, approved drawings and specifications: |
246 | Normal soil |
247 | Soft rock soil/soft rock/ metallic road/ RCC / kharanja |
248 | Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works. |
249 | Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work. |
250 | 11 kV Pin insulator with GI pin |
251 | 11 kV Disc insulator 70 KN with strain hardware |
252 | Erection, testing & commissioning of pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures and MS nuts, bolts & washers duly galvanizedincluding painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work. |
253 | Earthing arrangement as per technical specificatons,approved drawings and scope of work. |
254 | Excavation, erection, testing & commissioning of Spike Earthing 2540 mm long with 20mm solid GI Rod |
255 | Excavation, erection, testing & commissioning of Earthing Coil |
256 | Erection of 8 SWG GI wire for earthing and guarding by providing GI nut, bolts & washers, turn buckle etc |
257 | Laying of 11kV cable through HDD method including digging of pit |
258 | Digging of Trench .6 mtr wide .9 mtr to 1.5 mtr deep for laying of Pipe and Cable |
259 | NORMAL SOIL |
260 | SOFT ROCK/ kharanja |
261 | HARD ROCK / metallic road/ RCC |
262 | LAYING OF GI Pipe 6" dia in above digged trench and also for raising Cable on double Pole/Structure Laying of 11 KV Cable 3x185 sqmm |
263 | Laying of 11 kv Cable through above Pipe |
264 | Laying of Cable in above digged trench and also mounting Upto line by using bricks/ sand &stone pad as per REC norms |
265 | Making andMounting of heat shrinkable jointing kit for 11 KV 3x185 sqmm XLPE Cable |
266 | Digging suitable Pit and making straight through joint 11 KV 3x185 sqmm |
267 | Making of Straight Through joint andConstruction of RB Pit 3x1x1 mtr. with 9 inch thick side wall and 6 inch thick RCC bed along with RCC Trench Cover in Three Parts duly plastered and finsihed for housing St. through joint. box and filled with sand. |
268 | Road restoration Charges |
269 | NORMAL SOIL |
270 | SOFT ROCK / kharanja |
271 | HARD ROCK / metallic road/ RCC |
272 | Installationof 11 KVCAPACITOR BANK INCLUDING MOUNTING STEEL GALVANISED STRUCTURE AND ACCESSORIES AS REQUIRED AS PER DETAILED TECHNICAL SPECIFICATIONS, DRAWING AND SCOPE OF WORKS IN FOLLOWING ARRANGEMENTS: |
273 | CAPACITOR BANK 1200 KVAR - AUTO TYPE SUBSTATION MOUNTED WITH ALL ASSOCIATED EQUIPMENT LIKE 11 KV VCB ALONG WITH ADAPTER PANEL/COMPLETE MECHANISM FOR CONNECTION WITH EXISTING BUSBAR, C&R PANEL, CTs, 11 KV 200A ISOLATORS WITH EARTH SWITCH, RVT, 11 KV STATION CLASS LA, RED OXIDE / ALUMINIUM PAINTING, 2.5 SQ.MM. PVC ARMOURED STRANDED COPPER CONTROL CABLES, PROTECTION CIRCUIT AND EQUIPMENT, EARTHING, 16 MM DIA MS NUTS & BOLTS ETC AS REQUIRED AS PER APPROVED TECHNICAL SPECIFICATIONS, DRAWING AND SCOPE OF WORKS |
274 | CAPACITOR BANK 1500 KVAR - AUTO TYPE SUBSTATION MOUNTED WITH ALL ASSOCIATED EQUIPMENT LIKE 11 KV VCB ALONG WITH ADAPTER PANEL/COMPLETE MECHANISM FOR CONNECTION WITH EXISTING BUSBAR,, C&R PANEL, CTs, 11 KV 200A ISOLATORS WITH EARTH SWITCH, RVT, 11 KV STATION CLASS LA, RED OXIDE / ALUMINIUM PAINTING, 2.5 SQ.MM. PVC ARMOURED STRANDED COPPER CONTROL CABLES, PROTECTION CIRCUIT AND EQUIPMENT, EARTHING, 16 MM DIA MS NUTS & BOLTS ETC AS REQUIRED AS PER APPROVED TECHNICAL SPECIFICATIONS, DRAWING AND SCOPE OF WORKS |
275 | Erection of 11 Kv XLPE insulated 3x185 sqmm Armoured |
276 | Erection of Heat shrinkable Jointing Kit for 11 KV 3x185 sqmm XLPE Cable |
277 | Heat shrinkable Jointing kit for 11 KV 3x185 XLPE Cable-Indoor/Outdoor termination Kit |
278 | Layingof11 kV ACS dog covered conductor with all accessories. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy