Addition / Alteration To Strong Room At Reb ( E ) And Special Repair / Replacement Of Ber Electrical / Cooling Appliances At 19 Wing Under Ge ( Af ) Borjhar, borjhar-Assam

Military Engineer Services-MES has published Addition / Alteration To Strong Room At Reb ( E ) And Special Repair / Replacement Of Ber Electrical / Cooling Appliances At 19 Wing Under Ge ( Af ) Borjhar. Submission Date for this Tender is 23-06-2022. Air Conditioner Tenders in borjhar Assam. Bidders can get complete Tender details and download the document.




Tender Notice

32301363
Corrigendum : Addition / Alteration To Strong Room At Reb ( E ) And Special Repair / Replacement Of Ber Electrical / Cooling Appliances At 19 Wing Under Ge ( Af ) Borjhar
Open Tender
Indian
Assam
borjhar
23-06-2022

Tender Details

Addition / Alteration To Strong Room At Reb ( E ) And Special Repair / Replacement Of Ber Electrical / Cooling Appliances At 19 Wing Under Ge ( Af ) Borjhar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Jun-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-06-2022
2 13-Jun-2022 Date Corrigendum Date 20-06-2022
3 20-Jun-2022 Date corrigendum Date 23-06-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 58840.0 /-
Tender Value
INR 2.94 Crore /-

BOQ Items

Name of Work: ADDITION/ALTERATION TO STRONG ROOM AT REB (E) AND SPECIAL REPAIR/REPLACEMENT OF BER ELECTRICAL/COOLING APPLIANCES AT 19 WING UNDER GE (AF) BORJHAR
Sl. No. Item Description
1SCHEDULE "A"/BOQ OF B/R-I
2Surface dressing not exe. 15 cm deep in soft/loose soil complete all as specified and as directed..
3Excavating over areas not exe 1.50m deep and getting out in soft/ loose soil complete all as specified and as directed.
4Add additional 1.5m or part thereof in depth beyond the first 1.5m but not exe 3.00m complete all as specified and as directed.
5M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation as lean concrete for column footings, foundation below brick walls, etc. complete all as specified and as directed.
6M&L for RCC M-25 (using 20mm graded stone aggregates), design mix concrete as in Column footing, plinth beam, etc. complete all as specified and as directed.
7M&L for RCC M-25 (using 20mm graded stone aggregates), design mix concrete as in Column above footing up to bottom of roof beam complete all as specified and as directed..
8M&L for RCC M-25 (using 20mm graded stone aggregates), design mix concrete as in roof slab supported on beams, walls, etc. complete all as specified and as directed..
9M&L for RCC M-25 (using 20mm graded stone aggregates), design mix concrete as in roof beam complete all as specified and as directed.
10M&L for RCC M-25 (using 20mm graded stoneaggregates), design mix concrete as in lintel beam complete all as specified and as directed.
11M&L for RCC M-25 (using 20mm graded stone aggregates), design mix concrete as in chajja complete all as specified and as directed.
12M&L for formwork to sides of concrete foundations, footings, bases of columns, columns up to PB and plinth beams; and similar work; vertical or flat rough finished surfaces of concreate complete all as specified and as directed.
13M&L for formwork to sides of pillars, posts, struts, piers, columns, etc. rough finished surface complete all as specified and as directed.
14M&L for formwork to sides and soffits of lintel beam etc, rough finished surface complete all as specified and as directed.
15M&L for formwork to sides and soffit of chajja, etc. rough finished surface complete all as specified and as directed..
16M&L for formwork to sides and soffit of roofs, floor beams, etc rough finished flat concrete surface complete all as specified and as directed..
17M&L for formwork to sides and soffits of roofs, floor slabs, etc., finished surface not exc 200mm thick rough finished flat surface of concrete complete all as specified and as directed.
18M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
19All as per Serial item No. 18 here-in-before but 6mm to 8mm dia.
20All as per Serial item 18 here-in-before but 5mm dia and over upto and including 10mm dia as in stirrups, binders, etc.
21M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm each layer complete all as specified and as directed.
22M&L for removing excavated materials n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed
23M&L for brick work with sub class "B" bricks using old size bricks, exe 6m mean radious, built in cement mortar (1:6) complete all as specified and as directed.
24Forming embankments including raising (orlowering) earth, spreading in layers n. exc. 30cm thick; watering,ramming/rolling and finishingto requiredsize, shape, etc., n exc. 1.5m high from base complete all as specified and as directed.
25Sand filling under floors or in foundation includingwatering and consolidation complete all as specified and as directed.
26M&L for PCC (1:5:10) type E-2 (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and as directed.
27M&L for polythene film, 150 micron thick, laid on floor complete all as specified and as directed.
28M&L for rendering 15mm thick on other fair faces of brick work surfaces in cement mortar (1:6) as in internal plastering, finished even and fair without using extra cement complete all as specified and as directed.
29M&L for rendering 15mm thick on fair faces of brick work surfaces as in external plastering in two layers consisting 10mm thick in cement mortar (1:6) and top layer 5mm thick in cement mortar (1:4) with WPC @ 3% of cement by weight of cement or as per manufacturer"s instructions, finished fair and even without using extra cement complete all as specified and as directed. Note : WPC shall measured and paid separately.
30M&L for rendering 5mm thick on soffit of RCC ceiling and chajja surfaces in cement mortar (1:3), finished even and fair without using extra cement complete all as specified and as directed.
31M&L for preparing the new plasterd surfaces of ceiling and applying three coats of white washing complete all as specified and as directed.
32Supply only Integral water proofing compound, as per latest specification complete all as specified and as directed.
33M&L for preparing the new plasterd surfaces of external walls and applying two coats of exterior emulsion paint over and including one coat of primer (Camoflauge pattern) complete all as specified and as directed.
34M&L for preparing the new plasterd surfaces of Internal walls and applying two coats of oil bound distempering over and including one coat of primer complete all as specified and as directed.
35M&L for 40mm thick PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in sub base floorto receive tiling, etc. complete all as specified and as directed..
36M&L for 15mm thick screed bed or bedding in cement mortar (1:6) for laying floor finishes complete all as specified and as directed.
37M&L for 10mm thick plastering in cement mortar (1:4) for laying floor finishes as on vertical surfaces, such as dado, skirting, etc. complete all as specified and as directed.
38M&L for virified ceramic colured tiles, light shade 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sq.m, in floors, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
39All as per Serial item No. 39 here-in-before but as on vertical surfaces, such as dado, skirting, etc.
40M&L for preparation of roof surfaces for treatment and applying roof treatment complete all as specified and as directed as under : - (a) 10mm thick plastering in cement mortar (1:3) using 100% coarse sand on roof/ parapet wall with WPC @ 3% by weight of cement. (b) Applying a coat of bitumenous primer @ 0.40 litres/sq.m on prepared surfaces and allow to dry. (c) Applying a coat of hot blown bitumen 85/25 grade @ 1.2 Kgs/sq.m over primer. (d) Supply and laying of 3mm thick (minimum) APP based polymeric water proofing membrane weighing not less than 3 Kgs/Sqm, black finish reinforce with non woven plyster matt with help of torching with proplane or abutane gas using torch with min 75mm side overlap and 100mm end overlap as per manufactuers instruction. (e) Applying a tack coat of hot lown bitumen grade 85/35 @ 10.2 Kgs/sq.m. (f) Blinding wih dry coarse and @ 0.50 to 1.0 Kg/sqm dusted over bitumen. (g) The top surface shall be finished by a coat of aluminium paint @ 100 gms/sqm. Note : (i) Net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in grrove which sall be deemed to be included in quated rates. (ii) WPC shall measured and paid separately.
41M&L for anodised aluminium frame (Powder Coated) for doors, windows, ventilators, etc. with one or more rebates including joining cleats for fixing etc. complete all as specified and as directed.
42M&L for anodised aluminium door shutters (Powder coated), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws, etc.complete all as specified and as directed
43M&L for anodised aluminium window and ventilator shutters (Powder coated), side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings, such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified and as directed.
44S&F coloured sheet glass 4mm thick, ordinary quality and glazing with beads in square, not exc 0.5 sq.min each pane complete all as specified and as directed.
45S&F 5.5mm thick sheet glass,coloured and glazingin square in exc 0.5sq.m and n.exc 1.0sqm in each pane including solar control film 50 micron, non reflective type (greater sun control or equivalent)complete all as specified and as directed
46S&F for mortice lock, four lever aluminium body for aluminium door of size65mm complete all as specified and as directed
47S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor of size 140mm complete all as specified and as directed.
48S&F for door closer hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700mm in width and of weight not more than 35 kg and fixed aluminium (die cast) body complete all as specified and as directed.
49S&F for anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as per required and as directed.
50M&L for framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.n. exc. 10 kg each brackets, conforming to Fe-290, Gde-E-165 (brackets over 10 kg each to be measured under "Structural Steel") complete all as specified and as directed.
51M&L for surface preparation of new steel and iron and applying two coats of synthetic enamel paint over and including one coat of red oxide porimer complete all as specified and as directed.
52M&L broken stone or boulders for hard core of gauge n. exc. 63mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface as in plinth protection complete all as specified and as directed..
53M&L for 50mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection, finished even and smooth without using extra cement complete all as specified and as directed..
54Excavation in trenches n.exc 1.5m wide and n. exc. 1.5m in depth for foundations, etc. or manholes, pairholes, etc. n.exc 10sqm on plan and n. exc1.5min depth and getting out soft/loose soil complete all as specified and as directed.
55M&L for plain cement concrete (1:4:8) type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete, etc. complete all as specified and as directed.
56M&L for brick work with sub class "B" bricks, using old size bricks, straight or curved on plan exc. 6m mean radious, built in cement mortar (1:6)complete all as specified and as directed.
57M&L for rendering 10mm thick on cement mortar (1:6) onfair face of brick work of walls, finished even & smooth without using extra cementcomplete all as specified and as directed.
58M&L for rendering 15mm thick in cement mortar (1:4) onfair face of brick work of walls, etc. finished even & smooth without using extra cementcomplete all as specified and as directed.
59M&L for broken stone boulders of hard core of gauge n.exc 63mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to atrue surfaces complete all as specified and as directed.
60M&L for 100mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in sub base, surface finished fair and even complete all as specified and as directed.
61M&L for 50mm thick plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified and as directed.
62M&L for vitrified ceramic coloured tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36sqm, in floors, skirtings, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
63S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
64S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
65S&F steel work in tubular trusses including special shaped washers, etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 Grade St-240 complete all as specified and as directed.
66M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint complete all as specified and as directed.
67M&L preparation of newly untreated steel and iron surfaces of any description, not otherwise described, over 10 centimetre width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and as directed.
68M&L for perforated/semi-perforated 9mm thick ceiling tiles size 595mm x 595mm for insulation and acousic purpose including aluminium anodised section of size, wall angle 30mm x 25mm x 2mm thick, main/cross tee-section 15mm x 15mm x 1.4mm and suspended with 4.0mmdia GI wire of suitable length and including fixed and aluminium snap grid all as per clause 10.38.1 of SSR Part-I and as per manufacturer’s instructions complete all as specified and as directed.
69M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290.Gde-E-165 complete all as specified and as directed.
70M&L for mild steel flat iron of size 50x6mm for door and windows holdfast, etc. including necessary cutting, bending up to required size including necessary nut and bolt and drilling holes, etc. complete all as specified and as directed.
71M&L for angle iron of size 50x50x5mm for door and windows, etc. including necessary cutting, bending up to required size including necessary fixing or tee sections, fixed independently, without connection plate, etc. ofFe 410-W (Gde E-250) quality A complete all as specified and as directed.
72S&F butt hinges of size 100mm, medium weight, cold rolled mild steel complete all as specified and as directed.
73All as per Serial item No. 72 here-in-before but of size 75mm
74S&F mild steel barrel tower bolt of size 150mm long stove enamelled black with bright bolt complete all as specified and as directed.
75S&F mild steel pressed handle 150mm long oval type, stove enamelled black complete all as specified and as directed.
76S&F for collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with hold fasts and brackets complete all as specified and as directed.
77SCHEDULE "A"/BOQ OF E/M WORKS
78Supply and install digital voltage stabilizer wall mounted for automatic operation, single phase indoor type and designed for input variation between 170- 270 volt with output voltage 230-240 V ± 2.5% with digital voltmeter,time delay relay etc. for 2 TR AC complete all as specified and as directed. Make:-V-Guard/Microtek/Philips/Voltas or as recommended by OEM of AC"s.
79S&F fans ceiling bldc type, 5 star rated reulator compaitable with all accessories, down rod (length not less 400mm), connecting wire (length not less 650mm), 140- 285 V, 345 rpm, 1200mm sweep, air delivery 232.00 CMM, 0.9 Power Factor complete all as specified and as directed. Make- Atomberg (Type-Naveo)/Orient/Crompton/ Havells/Usha/Bajaj
80Supply and installation hi wall split units air conditioner indoor and outdoor complete with cordless remote control unit and with HD filter and anti virus protection for better indoor air quality of 1.5 TR capacity, minimum 5 star rated, inverter type, working in R-410a/R-32 refrigerant and making good disturbed surfaces of plastering plaster in cement mortar (1:6) and distempering/white washing to match the existing surface complete all as specified and as directed. Notes: (i) Cost of copper pipe of suitable size dia & thickness and copper cable of suitable sizes for connection with outdoor unit not exceeding 5.0m is deemed to be included in quoted rate. (ii) Cost of clamps alongwith fastner bolts for installation of outdoor unit of split ACs are deemed to be included in quoted rate
81Supply and installation hi wall split units air conditiner indoor and outdoor complete with cordless remote control unit and with HD filter and anti virus protection for better indoor air quality of 2.0 TR capacity, minimum 3 star rated, inverter type, working in R-410a/ R-32 refrigerant and making good disturbed surfaces of walls plaster in cement mortar (1:6) and distempering/white washing to match the existing surface complete all as specified and as directed. Make-Bluestar / Hitachi / Samsung/ Daikin/ LG Notes: (i) Cost of copper pipe of suitable size dia & thickness and copper cable of suitable sizes for connection with outdoor unit not exceeding 5.0m is deemed to be included in quoted rate. (ii) Cost of clamps alongwith fastner bolts for installation of outdoor unit of split ACs are deemed to be included in quoted rate.
82Supply and installation inverter type window AC with cordless remote control unit and anti-bacterial filter for better indoor air quality with minimum of 1.5 TR capacity and working in R-32/ R-410 A refrigerant, 220-240V, Single Phase, 50 Hz with ISEER not less than 3.50, 5 star rating and making good disturbed surfaces of wall with plastering in cement mortar(1:6) and distempering/white washing to match the existing surface complete all as specified and as directed .
83Supply and installation inverter type window AC with cordless remote control unit and anti-bacterial filter for better indoor air quality with minimum of 2.0 TR capacity and working in R-32/ R-410 A refrigerant, 220-240V, Single Phase, 50 Hz with ISEER not less than 3.50, 5 star rating and making good disturbed surfacesof wall with plastering in cement mortar(1:6) and distempering/white washing to match the existing surface complete all as specified and as directed .
84S&F storage type vertical water heater, capacity 25 litres, 2 kW, 230 V, 50 Hz, AC, with ultra thick super cold rolled steel plates and glass coated heating elements, 5 star rated on wall through fastener bolt complete and making good disturbed surfacesof wall with plasteringin cement mortar (1:6) and distempering/white washing to match the existing surface complete all as specified and as directed.
85S&F galvanized steel tubes of size 20mm bore, medium grade including all fittings and fixed on walls/ceilings/floors, etc. throgh MS clamp for AC"s drain water pipe complete all as specified and as directed.
86M&L for sub main wiring with two runs of single core PVC insulated unsheathed multi stranded copper conductor cable of size 4.0 Sq.mm 1100 volts grade and onerun of PVCinsulated unsheathed multistranded copper conductorcable of size4.0Sq.mm 1100 volts grade as earthcontinuity conductor drawn through in and including DLP U PVC trunking of 32x12.5mm size including all finishing accessories on roof/wall /ceiling, etc. complete and making good of wall/floor with cement plaster in cement mortar(1:6) and distempering /white washing to match the existing surface complete all as specified and as directed. Make : PVC Trunking- Legrand/Siemens/Indo Asian/Havells
87S&F PVC sheathed PVC insulated 4.0 sq.mm, 1100 volt, 4 core multistranded flexible copper conductor cable conforming to IS : 694or as recommeded by OEM for connection of indoor and out door unit ACs complete all as specified and as directed.
88S&F copper tube of size 1/2" or5/8" (suction) and1/4" or 3/8" dia (delivery, liquid) covered with 12mm thick PU Foam for outdoor and indoor unit connections or as per manufacturers recommendation for Split AC including all fittings and fixed on walls/ceilings through MS clamp complete all as specified and as directed.
89S&F industrial plug and socket enclosure (2 Pole and Earth) with MCB SP "C" Series, 6-32 Amps, 240 volt, 50 Hz, IP 43 on the wall complete by plastering in cement mortar(1:6) and making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified and as directed.
90S&F stainless steel flexi connection for geyser (45cm long) with check nut and washer complete including taking down the old unserviceable one complete all as specified and as directed. Make: Jaquar/AO Smith/Bajaj/Crompton Greaves/ Usha