West Bengal Agro Industries Corporation Limited-WBAIC has published Lt Electrical Job At Seed Godown, Office, Fertiliser, Pesticide Stores Of Seed Corporation At Chinsurah, Hooghly. Submission Date for this Tender is 03-06-2022. Electrical Maintenance Tenders in chinsurah West Bengal. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Interconnection with 3x300 +1x150 sqmm single core copper Conductor incl finishing the ends with sockets in flexible conduit of suitable size from metering arrangement to LT PANEL NO 1 |
2 | SITC OF LT PANEL AS PER ESTIMATE SPECIFICATION As per annexure-A |
3 | PUSH BUTTON STARTERS for Street lights 4 nos 2.0/1.5 KW LT make 1.0 Ph DOL starter Type MF1 |
4 | SUPPLY OF 300 Sq mm 3.1/2 Core PVC/A ALUMINIUM CABLE from wbsedcl METER RM MCCB 250A TO LT PANEL & DG TO LT PANEL MAKE OF CABLE-HAVELLS/GLOSTER/NICCO 1NO CABLES IN ROUTE LENGTH OF 100M ie CABLE LENGTH=100 M |
5 | 3. 1/2C Core 95 Sqmm PVCIA ALUMINIUM CABLE from LT PANEL TO 7 SEGMENT MCCB DB AT PLANT ROOM MAKE OF CABLE HAVELLS/GLOSTER/NICCO |
6 | 95 Sq mm 31/2 Core PVCIA ALUMINIUM CABLE from 7 SEGMENT MCCB DB to Processing Plant PANEL MAKE OF CABLE-HAVELLS/GLOSTER/NICCO |
7 | 3.1/2C Core 25Sqmm PVCIA ALUMINIUM CABLE fromLT Panel TO DIFFERENT DBS MAKE OF CABLE - HAVELLS/GLOSTER/NICCO |
8 | 3 Core 10 Sqmm from LT Panel /SB TO Gates MAKE OF CABLE HAVELLS/GLOSTER/NICCO |
9 | 3Core 10Sqmm PVCIA ALUMINIUM CABLE from LT Panel TO Street lights 10 poles for circuit 1 MAKE OF CABLE HAVELLS/GLOSTER/NICCO |
10 | 3Core 10Sqmm PVCIA ALUMINIUM CABLE from LT Panel TO Street lights 8 poles for circuit 2- MAKE OF CABLE HAVELLS/GLOSTER/NICCO |
11 | 3 Core 10 Sqmm PVC/A ALUMINIUM CABLE from LT 2 TO OH LINE- MAKE OF CABLE -HAVELLS/GLOSTER/NICCO. |
12 | 4 Core 6 Sqmm PVCIA ALUMINIUM CABLE from VTPN DB at Office TO proposed submersible pump- |
13 | 3Core 1OSqmm PVCIA ALUMINIUM CABLE from DG TO SPN DBS-MAKE OF CABLE -HAVELLS/GLOSTER/NICCO |
14 | CABLE LAYING CABLE LAYING FOR 3.1/2 CORE 300SQMM PVCIA AL Laying of one No. cable above 185 Sqmm in underground trench 460 mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. |
15 | Laying of two cables above 35 sqmm and upto 185 sqmm in underground trench 680 mm wide x760 mm average depth with brick protection on top of each cable with 8 nos bricks per meter and 4 nos bricks per meter as separator between bricks and cables and also trench to be filled with shifted soil ,levelling up and restoring surface duly rammed |
16 | Laying of one no cable (above 35 sqmm and upto 185 sqmm)3.1/2C 95sqmm in underground trench 460mm wide x760mm average depth with brick protection on top of the cable with 8 nos bricks per meter including filling the space between the brick & cable with shifted soil,levelling up and restoring surface duly rammed(for 95sqmm cable) |
17 | Laying of one no cable above 3.1/2 C95 sqmm and upto and 150 sqmm on wall/surface incuding S&F MS clamp with earthing attachment in 2x 10SWG GI(Hot Dip) wire ,making hole etc as necy mending good damages and painting.(for 95 sqmm cable) |
18 | Laying of one no cable upto 3.1/2 C 35 sqmm in underground trench 460 mm wide x760mm average depth with brick protection on top of the cable with 8 nos bricks per meter including filling the space between the brick & cable with shifted soil levelling up and restoring surface duly rammed (for 25 sqmm cable) |
19 | Laying of one no cable 3 C 10 sqmm in underground trench 460 mm wide x760mm average depth with brick protection on top of the cable with 8 nos bricks per meter including filling the space between the brick & cable with shifted soil, levelling up and restoring surface duly rammed( from LT Panel TO 10 nos Streetlight poles ckt 1) |
20 | Laying of one no cable 3 C 10 sqmm in underground trench 460mm wide x760mm average depth with brick protection on top of the cable with 8 nos bricks per meter including filling the space between the brick & cable with shifted soil, levelling up and restoring surface duly rammed ( from LT Panel 2 TO Street lights 8 poles for circuit 2) |
21 | Laying of one no cable 3 C 10 sqmm in underground trench 460 mm wide x760mm average depth with brick protection on top of the cable with 8 nos bricks per meter including filling the space between the brick & cable with shifted soil, levelling up and restoring surface duly rammed( from LT Panel TO existing Street lights) |
22 | Laying of one no cable 3 C 10 sqmm in underground trench 460 mm wide x760mm average depth with brick protection on top of the cable with 8 nos bricks per meter including filling the space between the brick & cable with shifted soil, levelling up and restoring surface duly rammed( from LT Panel TO existing Street lights) |
23 | Laying of one no cable 4 C 6 sqmm in underground trench 460 mm wide x760mm average depth with brick protection on top of the cable with 8 nos bricks per meter including filling the space between the brick & cable with shifted soil,levelling up and restoring surface duly rammed( from VTPN DB at Office TO proposed submersible pump. |
24 | Laying of one no cable 3 C 10 sqmm in underground trench 460 mm wide x760mm average depth with brick protection on top of the cable with 8 nos bricks per meter including filling the space between the brick & cable with shifted soil, levelling up and restoring surface duly rammed( from DG TO SPN DBS) |
25 | CABLE GLAND Cable Gland and joints Supplying and Fixing Compression type Gland complete with Brass, Rubber Rings for Dust and Moisture proof entry of PVC Armoured Cables as below. 300 Sq mm 31/2 Core PVCIA ALUMINIUM CABLE from CSS LTSIDE MCCB 250A FIRE PUMP ROOM & FROM DG SET TO FIRE PUMP ROOM TO LT PANEL. upto 300 sqmm wide |
26 | For 3 1/2 Core 185Sqmm From LT PANEL 1 TO LT PANEL 2 |
27 | For 3 1/2 Core 95 Sqmm from LT PANEL 2 to 7 segment DB and from 7 segment DB to Processing Plant Panel |
28 | For 3.1/2 Core 25 Sqmm PWD from LT Panel TO Different TPN DBS. |
29 | For 3 Core 10 Sqmm( fromLT Panel TO Gates) |
30 | For 3 Core 10 Sqmm( fromLT Panel TO Street lights 10 poles for circuit 1) |
31 | For 3 Core 10 Sqmm( fromLT Panel TO Street lights 8poles for circuit 2) |
32 | For 3 Core 10 Sqmm LT Panel 2 TO existing OH Road light |
33 | For 4 Core 6 Sqmm (fromVTPN DB at Office TO proposed submersible pump |
34 | For 3 Core 10 Sqmm( LT Panel 2 TO existing OH Road light |
35 | FINISHING OF END OF CABLE FINISHING the end of CABLE by crimping method including supplying and fixing dowels, solderless socket, tapes and joining materials for 3.1/2 C 185sqmm PVCIA ALCable From LT Panel 1 to LT Panel 2 |
36 | FINISHING the end of CABLE by crimping method including supplying and fixing dowels, solderless socket, tapes and joining materials for 3.1/2C 95 sqmm PVCIA Cable LT Panel 2 to 7segment DB Panel and from 7segment DB to Plant Panel |
37 | FINISHING the end of CABLE by crimping method including supplying and fixing dowels, solderless socket, tapes and joining materials for 3.1/2C 25 sqmm PVCIA Cable from L.T Panel 2 TO Different TPN DBs |
38 | FINISHING the end of CABLE by crimping method including supplying and fixing dowels, solderless socket, tapes and joining materials for 3C 10sqmm PVCIA Cable from LT Panel 2 TO Gates |
39 | FINISHING the end of CABLE by crimping method including supplying and fixing dowels, solderless socket, tapes and joining materials for 3C 10sqmm PVCIA Cablefrom LT Panel TO Street lights 10 poles for circuit 1 |
40 | FINISHING the end of CABLE by crimping method including supplyinng and fixing dowels, solderless socket, tapes and joining materials for 3C 10 sqmm PVCIA Cable from LT Panel TO Street lights 8poles for circuit 2 |
41 | FINISHING the end of CABLE by crimping method including supply ing and fixing dowels, solderless socket, tapes and joining materialsFor 3 Core 10 Sqmm( LT Panel 2 TO existing OH Road light. |
42 | FINISHING the end of CABLE by crimping method including supplying and fixing dowels, solderless socket,tapes and joining materials For 4 Core 6 Sqmm (fromVTPN DB at Office TO proposed submersible pump |
43 | FINISHING the end of CABLE by crimping method including supplying and fixing dowels, solderless socket,tapes and joining materials For 3 Core 10 Sqmm |
44 | EARTHING Earthing with 50mm dia galvanised iron pipe 3.64mm thick x 3.04m long and 1 x 4 SWG GI(Hot Dip) wire (4Mtrs long)13mm dia x80 mm long GI bolts, doublenuts , doublewashers incl. S&F 15mm dia GI Pipe protection (1m long) to be flled with bítumen partly under the ground level and partly above ground level driven to average depth of 3.65M below the ground level and restoring the surface duly rammed as belowFOR SOFT SOIL by ISI-Medium GI PIPE |
45 | Extra for treatment of soil by using salt and charcoal /coke for pipe electrode for soft soil |
46 | Extra for providing masonry enclosure on top of earth electrode of overall size 86.36cmx86.36cmx46cm deep (below ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement mortar(inside) ,C.I hinged cover of size 36.56cmx35.56cm with locking arrangement, G I reducer including drilling of 46 nos 12 nos 12mm holes on the GI pipe. |
47 | Connecting body of 7 SEGMENT DB to earth busbar including S & F 25mmx6mm Galvanised ms flat on wall/floor with Gl saddles as required and making connection to equipments with bolts, nuts washers etc |
48 | Supply & Fixing of Earth Bus Bar of Galvanised MS flat( 50mmx6mm) on wall having clearance a clearance of 6mm from wall including providing drilled holes on the bus bar complete with GI bolts,nuts,washers, spacing insulators as required. near Main LT Panel |
49 | Supply & Fixing of Earth Bus Bar of Galvanised MS flat(25mmx6mm) on wall having clearance a clearance of 6mm from wall including providing drilled holes on the bus bar complete with Gl bolts, nuts, washers, spacing insulators as required. Near Seed Processing Plant Unit |
50 | Extra for connecting Earth Busbar to earth station including S& F 50mmx6mm Galvanised steel tape on wall/floor with Gl saddles & insulating the same by one layer of PVC tape over one layer of ampire tape |
51 | Connecting body of Main Panel to earth busbar including S & F 50mmx6mm Galvanised ms flat on wall/floor with GI saddles as required and making connection to equipments with bolts,nuts,washers etc |
52 | Connecting Earth Electrode to earth busbar with 20mmx3mm galvanised (Hot Dip)MS flat on wall/floor with Gl saddles as reqd for connection including drilling holes with bolts, nuts,washers,etc |
53 | Connecting the equiments to earth busbar including S&F GI (Hot Dip)8 SWG wire on wall/floor as required with stapples buried\ inside wall/floor as required and making connection to equipments with bolts,nuts,washers,cable lugs etc as required and mending good damages. |
54 | MECHANICAL PROTECTION FOR CABLES G.I PIPE PROTECTION Supplying and fixing medium gauge G.I Pipe (1SI-MEDIUM )Pipe protection 100 mm dia pipe with necessary fittings and jointing materials as required |
55 | LT SUBSTN ROOM ei conduit,piano type switches Wiring with 1.1KV grade single core PVC insulated stranded copper wire in E.I conduit and painting 2x6 sq mm wire in 19 mm dia El conduit incl S&F1x14SWG GI ECC SPN DB NORMALSupplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages to original finish incl. Interconnection with suitable size of copper wire and neutral link & provision for earthing attachment. (ATLT ROOM) NORMAL DB |
56 | Legrand make 2+8 WAY Enclosure |
57 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
58 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA& C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Interconnection with suitable size of copper wire and neutral link & provision for earthing attachment. |
59 | Legrand make 2+4 WAY Enclosure |
60 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBS and necessary connection. Legrand DP 40A |
61 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10KA& C characteristics on din rail of existing DBs and necessary connection. |
62 | SUPPLY& FIXING AUTOMATIC CHANGE OVER SWITCH SINGLE PHASE MAKE- ELECTRON -DG SIDE 2A,MAINS 6A Supplying and fixing 250V 4 WAY SPN MCB DB with SS enclosure double door Lgrand maketo accommodate abovee Electron make AUTO MATIC CHANGE OVER SWITCH concealed in wall after cutting the wall & mending good the damages to original finish incl inter connection with suitable size of copper wire and neutral link &provision of earthing attachment. (ATLT RM OF SUBSTN ROOM)ACO) |
63 | Legrand make 2+4 WAY ENCLOSURE(607710) |
64 | DISTRIBUTION WIRING Distribution wiring in 2x1.5 sqmm single core PVCinsulated stranded Copper wire in 19 mm in blackstove El conduit to 3 pin Plug Pointsincl. S&F 5 A Piano Key type switch with earthing attachment in 16 SWG GI Wire and painting at WBSEDCL RM & LT RM Light Point Av run 6M |
65 | Ceiling Fan point Av run 6M |
66 | Exhaust Fan Point Av run 6M |
67 | 6A Switch socket on board |
68 | 6A Switch socket at AV RUN 6M |
69 | FAN REGULATOR Supply & Fixing Socket type fan regulator (Step type)(Brand approved by EIC) on existing sheet metal switchboard with bakelite/ perspex top cover by screw incl.making necessary arrangment. |
70 | Distribution Wiring 2x1.5 sqmm Single core PVC insulated stranded copper wire in 19mm in Black Stove El conduit to 3 pin plug point incl S&F 5A Piano Key type switch with earthing attachment in 16 SWG GI Wire and painting [at Godown] Wiring with 1.1 KV grade single core PVC insulated stranded Copper wire in El conduit and painting ON BOARD with 2x1.5 sqmm wire in 19 mm conduit incl. S&F 1x14 SWG GI ECC at GODOWN |
71 | Average run 6 mtr with 2x1.5 sqmm wire in 19 mm conduit incl. S&F1x14 SWG GI ECC |
72 | 16A POWER SOCKET WIRING (Surface) IN EI CONDUIT Wiring with 1.1KV grade single core PVC insulated stranded copper wire in E.l conduit and painting wire in 19 mm dia El conduit incl 1x14SNG GI ECC |
73 | Distribution wiring in 2x2.5 sqmm single corePVC insulated stranded Copper wire in 19mm El conduit/Gl conduit from separate way of BDB to 3 Pin 15 A plug point with 1x14SWG GI ECC (wiring only) |
74 | Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheetmetal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws aftermaking housing for switch by cutting bakelite/perspex Coverand making necessary connections as required |
75 | JB CUM SWITCH BOARD Supplying & Fixing CRC sheet metal (16 SWG) JB-cum-Switch Board of the following sizes complete with three nosuitable size Copper bar with holes (for Ph, N & E) fixed onbakelite/Hard the Rubber insulator Over MS welded chairs incl.bakelite/Perspex/coloured Perspex (wall matching colour) topcover 3 mm thick flushed in wall for housing the board aftercutting the brick wall incl. making earthing attachment painting and mending good damages to building works.150 mm x 100 mm x 65 mm |
76 | Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by ElC) on sheet metal switcn board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass Screws aftermaking housing for Switch by cutting bakelite/perspex Cover and making necessary connections as required |
77 | ELECTRICAL METER ROOM ei conduit, piano key type switches Wiring with 1.1KV grade single core PVC insulated stranded copper wire in E.I conduit and painting 2x6sq mm wire in 19 mm dia El conduit incl S&F1x14SWG GI ECC |
78 | SPN DB LIGHTS, CEILING FANS,EXHAUST FANS ETC FOR METER ROOM,ELECTRICAL ROOM, Supplying of 1200mm TUBE LED light fittings surface mounting type MAKE PHILIPS TYPE Astra BN150W LED13S-6500 PSE OD GR complete with holders (Philips MAKE ) Essential LEDtube 1200mm 16W 865 T8 and with necessary materials duly interconnection |
79 | Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitablesize of MS fastener |
80 | Electrical worksPage no-C2 ltem 14b) Supplying of 1200 mm sweep Ceiling without regulator (Make- Crompton/Orient) |
81 | Fixing only ceiling fan complete with blades,canopy,fork,rubber,bush etc incl S&F connecting wire(2x1.5 sqmm flexible copper wire ) for down rod upto 30cm incl. painting the rod with approved paint and making necessary connection as required |
82 | Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, box with alkathene sheet, placed in order to prevent concrete fromntering the box.incl. S&F 12mm dia 600mm long MS roduly bent by heat treatment at the centre position of rod to grip fanbobbin properly, incl. binding the rod and fan boxd by 22 SWG steel binding wire, incl. supplying & covering the with reinforcement |
83 | Supplying of Exhaust fan 23cm sweep (Make-EPC) |
84 | Fixing exhaust fan after making hole in wall and making good damages and smooth cement finish etc as practicable as possible and providing necy length PVC insulated wire and making connection for Exhaust fan of dia23cm |
85 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6dia x 62 mm long) mm for 23 cm Exhaust fan (9") GI |
86 | 16A POWER SOCKET WIRING (Surface) IN EI CONDUIT Supplying & Fixing composite flush type 250V 3pin 15A plug Socket with 15A Piano key type (Anchor)switch on sheet metal box with bakelite top cover and earthing attachment incl S & Fsheet metal box 175mmx100mm of 16SWG with bakelite top cover 3 mm thick |
87 | ETPN MCB PDB AT OFFICE FF DB 7 Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good thedamages to original finish incl. Inter connection with suitable size of copper wire and neutral ink & provisionfor earthing attachment Legrand 4 way Enclosure (607715) |
88 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10KA & C characteristics on din rail ofexisting DBs and necessary connection Legrand make FP415V 63A MCB) |
89 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10KA& C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A |
90 | Wiring with 1.1KV grade single core PVC insulated stranded copper wire in E.l conduit and painting sq mm wire in 19 mm dia El conduit incl S&F1x14SWG GI ECC( vide PWD Schedule Nov 2017 for Electrical worksPage no-E-1 A Item 1d) from ETPN DB AT GODOWN |
91 | SPN DB Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Interconnection with suitable size of copper wire and neutral link & provision for earthing attachment. (AT GODOWN ROOM) NORMAL DBLegrand make 2+8 WAY Enclosure (607711) |
92 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBS and necessary connection. Legrand DP 40A |
93 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA& C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A |
94 | DISTRIBUTION WIRING Distribution wiring in 2x1.5 sqmm single core PVCinsulated stranded Copper wire in 19 mm in blackstove El conduit to 3 pin Plug Points incl. S&F 5 A Piano Key type switch with earthing attachment in 16 SWG GI Wire and painting at GODOWN ON BOARD |
95 | Light Point Av run 6M |
96 | Ceiling Fan point Av run 6M |
97 | Exhaust Fan Point Av run 6M |
98 | 6A Switch socket on board |
99 | 6A Switch socket at AV RUN 6M |
100 | WIRING (Surface) (from ETPN DB to 16A Switch Board and from 16A switch board to Bulk head fittings) Wiring building wires(Finolex/KDK) in 20mm dia El conduit (NEC/BIC)surface type wiring including supply and fixing of 16A piano key type switch on MS box with cover and painting . |
101 | 16A POWER SOCKET WIRING (Surface) IN El CONDUIT Distribution wiring in 2x2.5 sqmm single corePVC insulated stranded Copper wire in 19mm El conduit/Gl conduit from separate wayof BDB to 3 Pin 15 A plug point with 1x14SWG GI ECC (wiring only) |
102 | Supply & Fixing 240 V, 20A, plug socket with separate 20 APiano key type switch (Brand approved by ElC) on sheetmetalswitch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws aftermaking housing for switch by cutting bakelite/perspex coverand making necessary connections as required |
103 | LIGHTS, CEILING FANS,EXHAUST FANS ETC FOR GODOWN Supplying of 1200mm TUBE LED light fittings surface mounting type MAKE PHILIPS TYPE AStra BN150W LED13S-6500 PSE OD GR complete with holders (Philips MAKE) Essential LED tube 1200mm 16W 865 T8 and with necessary materials duly interconnection. |
104 | Fixing only single /twin fluorescent light fitting complete With all accessories directly on wall/ceiling/HW round block and Suitablesize of MS fastener |
105 | Supplying of 1200 mm sweep Ceiling without regulator (Make-Crompton/Orient) |
106 | Fixing only ceiling fan complete with blades,canopy,fork, rubber bush, etc incl S&F connecting wire(2x1.5 sqmm flexible copper Wire ) for down rod upto 30cm incl.painting the rod with approved paint and making necessary connection as required. |
107 | Supplying & Fixing of Box type fan clamp of 150mm dia & 80 mmdepth made of 16 SWG CRCA sheet with one end duly sealed bycover, properly welded, box with alkathene sheet, placed in order to prevent concrete from entering the box.incl. S&F 12mm dia 600mm long MS roduly bent by heat treatment at the centre position of rod to grip fanbobbin properly, incl. binding the rod and fan boxdby 22 SWG steel binding wire, incl. supplying & covering the with reinforcement |
108 | Supplying ofExhaust fan 38cm sweep (Make-EPC) |
109 | Supplying ofExhaust fan 38cm sweep (Make-EPC) Fixing exhaust fan after making hole in wall and making good damages and smooth cement finish etc as practicable as possible and providing necy length PVC insulated wire and making connection for Exhaust fan of dia38 cm (15") |
110 | Supply & Fixing Gl sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) GI for38 cm Exhaust fan (15") |
111 | Supplying of Bulk head fitting complete with 1 no Philips make7W LED BULB (Philips Cat no FXC101) |
112 | Fixing of Bulk head fitting on wall FERTILISER STORE i.e conduit,piano key switch |
113 | ETPN DB AT FERTILISER STORE Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good thedamages to original finish incl. Inter Connection withsuitable size of copper wire and neutral link & provisionfor earthing attachment Legrand 4 way Enclosure (607715) |
114 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA &C characteristics on din rail ofexisting DBs and necessary Connection Legrand make FP415V 63A MCB |
115 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A |
116 | wiring with 1.1KV grade single core PVC insulated stranded copper wire in E.l conduit and painting 2x6 sq mm wire in 19 mm dia El conduit incl S&F1x14SWG GI ECC from ETPN DB AT FERTILISER STORE |
117 | SPN DB NORMAL AT FERTILISER STORE Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages to original finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthing attachment. (AT FERTILISER STORE) NORMAL DB Legrand make 2+8 WAY Enclosure (607711) |
118 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
119 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A |
120 | SUPPLY& FIXING AUTOMATIC CHANGE OVER SWITCH SINGLE PHASE MAKE- ELECTRON-DG SIDE 2A, MAINS 6A SPN MCB DB Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthing attachment. ( AT FERTILISER STORE ) FOR EDB |
121 | Legrand make 2+4 WAY Enclosure (607710) |
122 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
123 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A |
124 | WIRING Wiring with 1.1KV grade single core PVC insulated stranded Copper wire in E.l conduit and painting 2x6Sq mm wire in 19 mm dia El conduit incl S&F 1x14 SWG GI ECC TO SPN DB |
125 | DISTRIBUTION WIRING IN FERTILISER STORE Distribution wiring in 2x1.5 sqmm single core PVC insulated Stranded Copper wire in 19 mm in blackstove El conduit to 3 pin Plug Pointsincl. S&F 5 A Piano Key type switch with earthing attachment in 16 SWG GI Wire and painting at FERTILISER STORE LIght Point Av run 6M |
126 | Exhaust Fan Point Av run 6M |
127 | Exhaust Fan Point Av run 6M[PWD Schedule NOV 2017 Page-E- Exhaust Fan Point Av run 6M |
128 | 6A Switch socket on board |
129 | 6A Switch socket at AV RUN 6M |
130 | WIRING Wiring with 1.1KV grade single core PVC insulated stranded copper wire in E.l conduit and painting 2x6sq mm wire in 19 mm dia El conduit incl S&F1x14SWG GI ECC |
131 | 16A POWER SOCKET WIRING (Surface) IN EI CONDUITAT FERTILISER BLD Distribution wiring in 2x2.5 sqmm single corePVC insulated stranded Copper wire in 19mm El cond uit/Gl conduit from separate wayof BDB to 3 Pin 15 A plug point with 1x14SWG GI ECC (wiring only) |
132 | Supply & Fixing 240 V, 20A, plug socket with separate 20 APiano key type switch (Brand apprOved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws aftermaking housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
133 | LIGHTS, CEILING, FANS, EXHAUST FANS FOR FERTILISER STORESupplying of 1200mm TUBE LED light fittings surface mounting type MAKE PHILIPS TYPEAstra BN150W LED13S-6500 PSE OD GR Complete with holders (Philips MAKE) Essential LED tube 1200mm 16W 865 T8 and with necessary materials duly interconnection |
134 | Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitablesize of MS fastener |
135 | Supplying of Bulk head fitting complete with 1 no Philips make7W LED BULB (Philips Cat no FXC101) |
136 | Fixing of Bulk head fitting on wall |
137 | Supplying of 1200 mm sweep Ceiling without regulator (Make- Crompton/Orient) |
138 | Fixing only ceiling fan complete with blades,canopy,fork, rubber bush etc incl S&F connecting wire(2x1.5 sqmm flexible copper wire) for down rod upto 30cm incl.painting the rod with approved paint and making necessary connection as required |
139 | Supplying of Exhaust fan 38cm sweep (Make-EPC) |
140 | Fixing exhaust fan after making hole in wall and making good damages and smooth cement finish etc as practicable as possible and providing necy length PVC insulated wire and making connection for Exhaust fan of dia38 cm (15") |
141 | Supply & Fixing Gl sheet (20SWG) metal Cowl with MS flat iron frame & Gl wire mesh on wall with necy. bolts & nuts (6 mm diax62 mm long)GI for38 cm Exhaust fan (15") |
142 | PESTICIDE BUILDING Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42143 protection, concealedin wall after cutting the wall &mending good thedamages to original finish incl. Inter Connection withsuitable size of copper wire and neutral link & provisionor earthing attachmentLegrand 4way Enclosure (607715) LEGRAND |
143 | 4P 63A,415V MCB 1OKA AS INCOMER AT ETPN DB Supplying and fixing 415 V63A 4P MCB of Breakingcapacity 10kA & C characteristics on din rail ofexisting DBs and necessary ConnectionLEGRANDvide PWD SCHEDULE NOV2017 D6 Legrand |
144 | SP 6-32A 240V MCB 10KA AS OUTGOING AT ETPN DB Supplying and fixing 240 V 6-32A SP MCB of Breaking capacity 10KA & C characteristics on din rail ofexisting DBs and necessary Connection LEGRAND |
145 | SPN DB NORMAL Supplying and fixing double-door SPN MCB DistributionBoard With IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection With suitable size ofcopper wire and neutral link & provision for earthingattach ment.Enclosure (607711 Legrand 2+8 way LEGRAND |
146 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.Legrand DP 40A |
147 | Supplying and fixing 240 V 10-32A SP MCB of Breakingcapacity 10kA & C characteristics on din rail ofexisting DBs and necessary Connection LEGRAND Supplying and fixing double-door SPN MCB DistributionBoard with 1P-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthing attachment. (AT FERTILISER STORE) FOR EDB Legrand make 2+8 WAY Enclosure (607710) |
148 | Legrand make 2+8 WAY Enclosure (607710) |
149 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection. Legrand DP 40A |
150 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary connectionLegrand SP 6-32A |
151 | WIRING (Surface) 16A switch board to Bulk head fittings ) for store building group control of 5 nos of light fittings Wiring with 1100 V olt grade PVC insulated flame guard single core 2x2.5sq mm +1x1.5 sq mm copper conductor wires(Finolex/KDK) in 20mm dia El conduit (NEC/BIC)surface type wiring including supply and fixing of 16A piano key type switch on MS box with cover and painting |
152 | 16A POWER SOCKET WIRING (Surface) IN EI CONDUIT Distribution wiring in 2x2.5 sqmm single core PvC insulated stranded Copper wire in 19mm El conduit/Gl conduit from separate wayof BDB to 3 Pin 15 A plug point with 1x14 SWG GI ECC (wiring only). |
153 | Supply & Fixing 240 V, 20A, plug socket with separate 20 APiano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by housing for switch by cutting Brass Screws after making bakelite/perspex coverand making necessary connections as required. |
154 | Distribution wiring in 2x2.5 sqmm single corePVC insulated stranded Copper wire in 19mm El conduit/Gl conduit from separate wayof BDB to 3 Pin 15 A plug point with 1x14SWG GI ECC (wiring only) |
155 | Supply & Fixing 240 V, 20A, plug socket with separate 20 APianob key type switch (Brand approved by EIC) on sheetmetalswitch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws aftermaking housing for switch by cutting bakelite/perspex coverand making necessary connections as required |
156 | LIGHTS,CEILING FANS,EXHAUST FANS ETC FOR PESTICIDE STORE Supplying of 1200 mm TUBE LED light fittings surface mounting type MAKE PHILIPS TYPE Astra BN 150 W LED 13 S-6500 PSE OD GR complete with holders .(Philips MAKE) Essential LED tube 1200 mm 16W 865 T8 and with necessary materials duly interconnection. |
157 | Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HN round block and suitablesize of MS fastener |
158 | Supplying of 1200 mm sweep Ceiling without regulator (Make- Crompton/Orient) |
159 | Fixing only ceiling fan complete with blades,canopy,fork, rubber bush etc inc S&F connecting wire(2x1.5 sqmm flexible copper wire ) for down rod upto 30cm incl.painting the rod with approved paint and making necessary connection as required |
160 | PROCESSING PLANT ei conduit,piano switch WIRING Wiring with 1.1KV grade single core PVC insulated stranded Copper wire in E.l conduit and painting 2 x6 sq mm wire in 19 mm dia El conduit incl S&F 1x14 SWG GI ECC.From 7 SEG DB 2 SPN DB. |
161 | Distribution wiring in 2x1.5 sqmm single core PVCinsulated stranded Copper wire in 19 mm in blackstove El conduit to 3 pin Plug Pointsincl. S&F 5 A Piano Key type switch with earthingattachment in 16 SWG GI Wire and painting at PROCESSING PLANT Light Point Av run 6M |
162 | Ceiling Fan point AV run 6M |
163 | Exhaust Fan Point Av run 6M |
164 | 6A Switch socket at AV RUN 6M |
165 | 6A Switch socket at AV RUN 6M |
166 | WIRING (Surface) (from DB to 16A Switch Board and from 16A switch board to Bulk head fittings) for GODOWN for group control 5 nos. of light fittings Wiring with 1100 V otl grade PVC insulated frame guard single core 2x 2.5 sqmm + 1x 1.5 sqmm copper conductor wires (Finolex DK) in 20 mm dia EI conduit (NEC/BIC) surface type wiring including supply and fixing of 16 A piano key type switch on MS box with cover and painting. |
167 | Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suítable size ofcopper wire and neutral link & provision for earthingattachment.Enclosure 607711 LEGRAND 2+8way,vide PWD SCHEDULE NOV2017 item no 13 page -D9 Legrand AT PROCESSING PLANT NORMAL DB |
168 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
169 | Supplying and fixing 240 V 6-32A SP MCB of Breakingcapacity 10kA & C characteristics on din rail of existing DBs and necessary connection LEGRAND |
170 | Supplying and fixing double-door SPN MCB DistributionBoard with IP-42143 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthingattachment. ( AT PLANT ROOM ) FOR EDBSUPPLY& FIXING AUTOMATIC CHANGE OVER SVWITCH SINGLE PHASE MAKE- ELECTRON-DG SIDE 2A,MAINS 6A |
171 | Legrand make 2+4 WAY Enclosure (607710) |
172 | 16A POWER SOCKET WIRING (Surface) IN EI CONDUIT Distribution wiring in 2x2.5 sqmm single corePVC insulated stranded Copper wire in 19mm El conduit/Gl conduit from separate wayof BDB to 3 Pin 15 A plug point with 1x14SWG GI ECC (wiring only) |
173 | Supply & Fixing 240 V, 20A, plug socket with separate 20 APiano key type switch (Brand approved by ElC) on sheetmetalswitch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws aftermaking housing for switch by cutting bakelite/perspex coverand making necessary connections as required |
174 | TPN 7 SEGMENT MCCB DB AT PROCESS PLANT ei conduit,piano type switch DB 18 Supplying &Fixing 415V TPN double door MCCB distribution Board(Make Siemens/Legrand/Schneider/ABB) in manufacturer"s MS enclosure incoming MCCB(25KA) and outgoing with "C curve MCBs (Make-siemens/LEGRAND/SCHNEIDER MG)includingrequired no of blank plates, interconnection, complete board FLUSHED on wall including cutting chase on wall and mending good damages and painting as follows (note :MCB shall have 1OKA with stand capacity and c curve characteristic. 6 WAY TPNMCCB DB ( 7 seven segment) at tPLANT ROOMwith the following- 1) 125A 4P MCCB (25KA)-1 no as incomer Outgoing,TPN 125A MCB (10KA) - 1 No. SP 32-2 NOS,16A MCB-10 nos. |
175 | GATE LIGHTSSupply and fixing of Post Top Lantern lightswith spherical cover Philips type no SPC 106 /70() incl 1xSON 70W (I) Sodium Vapour lamp with pipes&fixtures ,proper foundatlon ,necessary Civl work, structural work,pipe protection etc. |
176 | SWITCHING ARRANGEMENT FOR GATE LIGHTS SEF LEGRAND make Mosaic type grey IP 55 Plexo box cat no 069651 for 2 module |
177 | S&F LEGRAND make Mosaic type grey adaptor for IP 65 Plexo with smoked polycarbonate flap for 2 modules cat no 069580 |
178 | STREET LIGHTS Supplying at site swaged type tubular poles with sole plate and Cl cap of overall lengfh 9M as per 1S:2713 (Part-l) 1980 and designation 410-SP-30 approximate welght of 133 kg. (Calcutta Poles & Tube Co.) complete with holes at bottom for entry of cable /pipe and earth bolt. |
179 | Erection of the said pole with sole plate in CC foundation of 6.3:1 and 0.6M x 0,6M x 1.7M dimension as to GS having 600mm x 600mm x 150mm thick CC (4:2:1) base block below sole plate with hard jhama metal including CC (6:3:1) muffing 0.3 mts dia and o.3mt above ground level including 3 mm thick neat cemented finish and Gl earth bolt after making drilled holes etc on pole & carriage of pole upto 1.6Km from store to work site including up the excavated earth pit with shifted soil and ramming properly. |
180 | Supplying & Fixing Cl waterproof type looping cable box size 200 x 150 x 100mm deep having 4mm thick comprising one 250 V 15A kitkat fuse unit ,one NL on porcelain insulator,one compression type brass cable gland for upto 2-core 16 sqmm PVC/A cable and having lined with gasketted Gl top cover withh brass machine screws etc, earthing terminal with lug on steel tubular pole near base , including S &F 40x6mm thick ,MS clamps with bolts,nuts, etc including painting with anticorrosive paint. |
181 | Supply to the site "Philips" make 150 W HPSV Luminaireof Pot optics reflector and toughened glass cover complete with all the accessories and HPSV lamp of SON-I 150W lamp Cat. No. SRX 51/150. |
182 | Fixing of outdoor type fluorescent /SV/MV light fitting on pole including S&F 40mm dia x 1.68mts long Gl Pipe (1SI-Medium) bracket 4Ommx10 mm thick MS clamp etc, and providing wiring with 2x1/1.40 PVC insulated and sheathed wire (single core) from loop box at the base of pole to light fitting through pole and bracket ( without control switch & painting |
183 | Painting the entire length of the pole and the arm bracket by ready mixed paint/primer of superior make and brand including preparation of the surfaces of both by sand/emery paper, cleaning, etc., by 2 coats of aluminjum paint on 1 coat of RO primer |
184 | Individual earthing of each pole by 1 x 25mm dia 10" long Gl rod driven to the ground and connecting with the earth bolt of the pole by 1 x4 SWG- GI wire, when the other end of the Gl wire connected with the Earth electrode by Gl nut, bolt and washer, etc, of suitable size and providing 15mm dia x 1M long Gl pipe for protection of the earth wire by fixing the pipe by compound. |
185 | Supplying of 1200mm TUBE LED light fittings surface mounting type MAKE PHILIPS TYPEAstra BN150W LED13S-6500 PSE OD GR complete with holders (Philips MAKE )Essential LEDtube 1200mm 16W 865 T8 and with necessary materials duly interconnection |
186 | FIxing only fluorescent light fitting suspended 25 cm below the celling with 2 nos 20mm dia E.l conduit (14SWG) supports incl S&F El conduit ball socket/socket type ceiling plate and connecting the length of 2x24/0.20 mm pvc insulated flexible copper wire of 1.10mt long and painting as required. |
187 | Extra for suspension exceeding 25cm with S&F additional 2x20 mm dia E.I conduit (14 SWG) supports and necy pvc insulated 2x 24/0.20mm flexible copper wireof 1.1mt length and painting |
188 | Supplying of Bulk head fitting complete with 1 no Philips make LED 2W lamp (Philips Cat no FXC101) |
189 | Fixing of Bulk head fitting on wall |
190 | Supplying of Exhaust fan 38 cm sweep (Make-EPC) |
191 | Fixing exhaust fan after making hole in wall and making good damages and smooth cement finish etc as practicable as possible and providing necy length length o PVC insulated wire and making connection for Exhaust fan of dia 38 cm |
192 | Fixing only louver shutter/cowl on wall with necy. Bolts& nuts (6mmx62mm long) for 38 cm exhaust fan |
193 | Supplying and Fixing of 6" Alarm bell with gong metal clad type make "NATIONAL"230 V on MS box flush mounted |
194 | Supplying of 1200 mm sweep Ceiling without regulator (Make- Crompton/Orient) |
195 | Fixing only ceiling fan complete with blades,canopy,fork, rubber bush , etc incl S&F connecting wire(2x1.5 sqmm flexible copper wire ) for down rod upto 30cm incl.painting the rod with approved paint and making necessary connection as required |
196 | Supplying & Fixing of Box type fan clamp of 150mm dia & 80 mmdepth made of 16 SWG CRCA sheet with one end duly Sealed bycover, properly welded, boxwith alkathene sheet, placed in order to prevent Concrete fromntering the box.incl. S&F 12mm dia 600mm long MS roduly bent by heat treatment at the centre posiftion of rod fo grip fanbobbin properly, Incl. binding the rod and fan boxdby 22 SWG steel binding wire, incl. supplying & covering the with reinforcement |
197 | FAN CLAMPS Supplying &Fixing MS fan clamp of two plece type for RC ceiling as per approved specification, fabricated from 40mmx9mm MS at including making good the damage s to building roof with Sallactory finishing and painting(As per Drawing no 475 of PWD SPECIFICATION BOOK-May 1991)(( vide PWD Schedule April 2014 for Electrical worksPage no-G-2Supplying &FXIng electonic step regulator of make Anchor for 1200mm Ceiling fan in the prelaid SB for lights and fans Item 4c) 1 |
198 | IN OFFICE BUILDING Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43protection, on angle iron frame on wall & mending goodthe damages to original finish incl. Inter connection withsuitable size of copper wire and neutral link & provisionfor earthing attachmentLegrand 8 way make Enclosure (607914) |
199 | Supplying and fixing 415 V Four Pole MCCB ofBreaking capacity magnetic adjustable 25kA/35kA with fixed thermaand fixed magnetic adjustable DBs/ enclosure thermal and fixedmagnetic setting in existing DBs enclosure Schedule and nnecessary connectionLegrand125 A |
200 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA & C characteristics on din rail ofexisting DBs and necessary connection Legrand |
201 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA & C characteristics on din ral ofexisting DBs and necessary DBs and necessary connection Legrand SP 6-32A |
202 | ETPN DB AT OFFICE ESSENTIAL Supplying and fixing double door Horizontal TPN MCBDistribution board with IP-42/43 protection, concealedin wall after cutting the wall & mending good thedamages to original finish incl. Inter connection withsuitable size of copper wire and neutral link & provisionfor earthing attachment Legrand 4 way Enclosure (607715) |
203 | Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the dam ages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthingattachment. (AT FERTILISER STORE ) FOR EDB Legrand make 2+4 WAY Enclosure (607710)FOR EDB |
204 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
205 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary connectionLegrand SP 6-32/A |
206 | SPN DB Supplying and fixing 250V,6-10A per way, SPN MCB DB with SS enclosure double door with DPP isolators as incomer and SPMCBs (C Curve, 10A) as outgoing concealed in wall after cutting the wall & mending good the damages to original finish incl inter connection withsuitable size of copper wire and neutral link (AT OFFICE & provision of earthing attachment Legrand make 2+8WAY Enclosure (607711) 40A |
207 | SUPPLY& FIXING AUTOMATIC CHANGE OVER SWITCH SINGLE PHASE MAKE- ELECTRON -DG SIDE 2A,MAINS 6A |
208 | Supplying and fixing 250V SPN MCB DB with SS enclosure double door to accommodate above Electron make AUTO MATIC CHANGE OVER SWITCH concealed in wall after cutting the wall & mending good the damages to original finish incl inter connection with suitable size of copper wire and neutral link & provision of earthing attachment. |
209 | INTERNAL WIRING FOR LIGHT/FAN ETC. Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded"FR" PVC insulated & unsheathed single core stranded copper wire (Brand approved by ElC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finishlight point controlled by one way 6A switch av run 6 M. |
210 | Wall fan 6m av run |
211 | Exhaust fan 6m av run |
212 | Call bell point 6m av run |
213 | 6A SWITCH AND SOCKET Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded "FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module Gl switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. IN OFFICE BUILDING On Board |
214 | Av run 6M |
215 | OFFICDE BUILDING, SUB MAIN WIRING (From ETPN DB AT OFFICE at G Floor to SPNDB EDB at first floor Supplying and fixing polythene pipe complete with fittings as necy under celing/beam, bound with 22 SWG GI binding wire indi. Supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of lMS sheet (20 SWG) having colour paint at one face fastened with fish wire a the load point end of the polythene pipe with fish wire (Synchronizing with roof/beam casting work of building Construction) for 19mm dia 3mm thick Polythene Pipe. |
216 | Cutting channel of 40mmx40mm size masonry wall incl S&F heavy gauge polythene pipe 19mm dia 3mm thick polythene pipe without earth continuity wire by means of iron hooks and supplying and drawing 18 swg Gl wire as fish wire incl mending good damages to building works |
217 | Supplying and Drawing 1.1 KV single core stranded "FRPVC insulated & unsheathed single core stranded copper wire(Brand approved by ElC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and makingnecy. connection as required 2 x8 4/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC |
218 | LIGHTS, CEILING FANS,EXHAUST FANS ETC FOR OFFICE Supply of (i) Natural cool daylight (500 5900K), (i) CRCA Metal sheet recess mounted LED Luminaire (make -Philips) suitable for 2x2 grid ceiling (40OW). Crompoton Greaves |
219 | Fixing of recess mounted LED Luminaire (make -Philips) suitable for 2x2 grid ceiling (40W) or Equivalent Brand: Havells/Wipro including cutting the ceiling,S &F steel conduitinstaller ,other materials, etc, wherever necessaryand Wiring with termination |
220 | Supply of recessed mounted BBS170 1XDLED -5000 PSU WH round DOWN LIGHTER,15N (make -Philips) LED Light Fixtures The price includes suplly of lamps also.Equivalent Brand: Havells I Wipro / Crompton Greaves. |
221 | Fixing of BBS170 1XDLED -5000 PSU WH round DOWN LIGHTER,15W (make -Philips) LED LIght Fixtures or Equivalent Brand: Havells / Wipro including cutting the ceiling,S &F steel conduit/installer ,other materials, etc, wherever necessaryand Wiring with termination. |
222 | Supplying of 1200mm TUBE LED light fittings surface mounting type MAKE PHILIPS TYPEAstra BN150W LED13S-6500 PSE OD GR complete with holders .(Philips MAKE ) Essential LEDtube 1200mm 16W 865 T8 and with necessary materials duly interconnection |
223 | Fixing only fluorescent light fitting only single/twin fluorescent directly on wall/ceiling by screws etc. |
224 | Supplying of Philips make surface mounted LED DOWN LIGHTER TYPE DN17 OC LEDIOS-6500 PSU WH |
225 | Fixing only surfacemounted ceiling fitting on wall lceiling by Screws etc. Philips make LED DOWN LIGHTER TYPE DN17 OC LEDIOS-6500 PSU WH |
226 | Supplying of Exhaust fan 23cm sweep (Make-EPC) |
227 | Fixing exhaust fan after making hole in wall and making good damages and smooth cement finish etc as practicable as possible and providing necy length PVC insulated wire and making connection for Exhaust fan of dia 23cm |
228 | Fixing only louver shutter/cowl on wall with necy. Bolts & nuts (6mmx62mm long) for 23 cm exhaust fan. |
229 | Supplying &Fixing of250V AC Buzzer (Make-Anchor-821 7) on on HW board on wall incl S&F HW board |
230 | Supplying of 1200 mm sweep Ceiling without regulator (Make- Crompton/Polar) |
231 | Fixing only ceiling fan complete with blades,canopy, fork, rubber bush, etc incl S&F connecting wire (2x1.5 sqmm flexible copper wire) for down rod upto 30cm incl.painting the rod with approved paint and making necessary connection as required. |
232 | Supplying of 400 mm sweep wall fan (Make- Crompton/Polar) |
233 | Fixing of 400 mm sweep wall fan(Make- Crompton/Orient)on wall by S&F rag bolts, nuts & washers (6mm dia x 62mm long) or as required incl S&F 24/0.2 PVC insulated flexible copper wire 0.5 mt long no-G-2 Item 4c) |
234 | FAN CLAMPS Supplying &Fixing MS fan clamp of two piece type for RC ceiling as per approved specification , fabricated from 40mmx9mm MS flat including making good the damage s to building roof with satifactory finishing and painting -(As per Drawing no 475 of PWD SPECICIFICATION BOOK-May 1991) |
235 | Supplying &Fixing electonic step regulator of make Anchor for 1200 mm Ceiling fan in the prelaid SB for lights and fans. |
236 | 16A PONER SOCKET WIRING (concealed) IN POLYTHENE PIPE Supplying and fixing rigid pvc pipe/polythene pipe of size 19mm bore, 3mm thickcomplete with fitting as necyunder celling/beam/over false ceiling ,bound with 22SWG GI binding Wire incl supplying and drawing 1x18 SWG GI wire as fish wire inside the pipes fittings and providing 50mm dia disc of ms sheet (20SWG) having colour paint at one face fastened at the load point end of polythene pipe with fish wire (synchronising with roof/beam casting work of building construction) |
237 | Cutting channel of 40mmx40mm size masonry wall incl S&F heavy gauge polythene pipe 19mm dia 3mm thick polythene pipbe without earth continuity wire by means of iron hooks and Supplying and drawing 18 swg G wire as fish wire incl mending good damages to building works. |
238 | Supplying and Drawing 1.1KV single core stranded FR PVC insulated & unsheathed single core stranded copper Wire(approved make) of the following in prelaid polythene pipe and by the prelaid fish GI wireand making necy connection as required2x36/0.3(2.5sqmm )+1x22/0.3 (1.5 sqmm) as ECC |
239 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by ElC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire |
240 | Wiring in 1.1KV grade single core stranded FR" PVC insulated & unsheathed copper wire (approved make) of following sizes 2x36/0.3(2.5sq mm +1x22/0.3(1.5 sq mm) 19mm bore 3 mm thick polythene pipe concealed in wall/floor with all necessary materials cutting chase/groove and mending good the damages to original finish |
241 | Supplying & Fixing 250V 3 pin 16A Piano key type (Anchor)switch on sheet metal box with bakelite top cover and earthing attachment incl S & F sheet metal box of size175mm x100mm (16SWG) with 3 mm thick bakelite top cover at office |
242 | A/C POWER UNIT WIRING Wiring with 1100 V olt grade PVC insulated flame guard single core 2x4 sq mm +1x2.5 sq mm copper conductor Wires (Finolex/KDK) in 19mm bore 3mm thick polythene pipe Concealed in wall /floor by cutting chase/groove with all necessary materials and mending good the damages to original finish |
243 | Supplying of A/C Power Units ( North West Cat no ACPU 6M -BT) flush type with DP MCB,Single Phasestarter with overload relay 11-18 A range,25A socket& plug with indicating lamp complete with PVC Modular box for 1.5 T A/C Make North West |
244 | Fixing of A/C Power Units for 1.5 TA/C Make North West |
245 | Supplying of Window A/C M/C for 1.5 T AIC Make Blue Star/Hitachi/Voltas |
246 | Installation of Window A/C M/C for 1.5 T A/C Make Blue Star/Hitachi/Voltas |
247 | WATER COOLER CUM PURIFIER Supply of Water Cooler cum Purifierof storage capacity 80ltrs,50 Itrs/hr make Eureka Fobes,type Eureka Fobes Aquaguard Pro Chill RO 80 PSS/Blue star water cooler SDLx 480 with combination of Alfaa Water Purifier |
248 | Installation ,Testing and commissioning of Water Cooler cum Purifierof storage capacity 80ltrs,50 ltrs/hr make Eureka Fobes,type Eureka Fobes Aquaguard Pro Chill RO 80 PSS/Blue star water cooler SDLx 480 with combination of Alfaa Water Purifier |
249 | DBS DB1 AT PUMP HOUSE 4WAY ETPN MCB DB Supplying and fixing double door Horizontal TPN MCBDistribution board with IP-42/43 protection, concealedin wall after cutting the wall & mending good thedamages to original finish incl. Inter connection withsuitable size of copper wire and neutral link & provisionfor earthing attachment |
250 | Legrand 4 way Enclosure (607715) |
251 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary connectionLegrand SP 6-32A |
252 | 8WAY SPN MCB LDB at processing plant & LT ROOMS-2NOS Supplying and fixing double-door SPN MCB DistributionBoard with IP-42143 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthing attachment. ENCLOSURE (607711) LEGRAND 2+8 way LEGRAND at PRESTISIDE Building. |
253 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
254 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A |
255 | 8 WAY SPN MCB LDB at PESTICIDE BLD DB17 Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthing attachment Enclosure (607711) Legrand 2+8 way LEGRAND |
256 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
257 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A |
258 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A. Lagrand 4 way Enclosour (607715) |
259 | Lagrade make FP415V 63 A MCB |
260 | Supplying and fixing 240/415V MCB Mreaking Capacitor 10KV & C Charecteristicon din rail of existing DB s and necessaryconnectionLegrand SP 6-32A |
261 | 4W TPN MCB PDB AT OFFICEAT GROUND FLR DB7Supplying and fixing doudle door Horizontal TPN MCB Distribution board with IP-42/43 protection , conceledin wall after cutting the wall & mending good the damages to original finish incl. the inter connection with suitable size of copper wire and neutral link & provision for earthening attachment. Legrand 4 way Enclosure (607715) |
262 | Legrand make FP415V 63A MCB) |
263 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DEBs and necessary ConnectionLegrand SP 6-32A |
264 | 4W TPN MCB LDB AT OFFICE AT GROUND FLR DB9 Supplying and fixing double door Horizontal TPN MCBDistribution board with IP-42/43 protection, concealedin wall after cutting the wall & mending good thedamages to original finish incl. Inter connection withsuitable size of copper wire and neutral link & provisionfor earthing attachment Legrand 4 way Enclosure (607715) |
265 | Legrand make FP415V 63A MCB) |
266 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A. |
267 | 4W TPN MCB PDB AT FERTILISER BUILDING DB10 Supplying and fixing double door Horizontal TPN MCBDistribution board with IP-42/43 protection, concealedin wall after cutting the wall & mending good thedamages to original finish incl. Inter connection withsuitable size of copper wire and neutral link & provisionfor earthing attachment Legrand 4 way Enclosure (607715) |
268 | Legrand make FP415V 63A MCB) |
269 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary |
270 | 4W TPN MCB PDB AT FERTILISER BUILDING DB19 Supplying and fixing double door Horizontal TPN MCBDistribution board with IP-42/43 protection, concealedin wall after cutting the wall & mending good thedamages to original finish incl. Inter connection withsuitable size of copper wire and neutral link & provisionfor earthing attachment Legrand 4 way Enclosure (607715) |
271 | Legrand make FP415V 63A MCB) |
272 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary connectionLegrand SP 6-32A |
273 | 8WAY SPN MCB LDB at office RM FF DB 11 Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthing attachment. Enclosure (607711 Legrand 2+8 way LEGRAND Legrand at PRESTICIDE BUILDING. |
274 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
275 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A |
276 | 8WAY SPN MCB LDB at PESTICIDE BLD DB17 Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthing attachment. Enclosure (607711)Legrand 2+8 way LEGRAND |
277 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
278 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A |
279 | 8WAY SPN MCB LDB at FERTILISER BLD DB20 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthing attachment. ENCLOSURE (607711 LEGRAND 2+8 way LEGRAND |
280 | Supplying and fixing 2401415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
281 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA& C Charecteristic on din rail of existing DGs and necessary connectionLegrandSP-32 A. |
282 | 8WAY SPN MCB LDB at GODOWN Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthing attachment. Enclosure (607711Legrand 2+8 wayL.EGRAND |
283 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
284 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A |
285 | 8WAY SPN MCB LDB at PESTICIDE BLD DB17 Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthing attachment |
286 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
287 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A |
288 | 8WAY SPN MCB LDB at FERTILISER BLD DB20 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthing attachment. Enclosure (607711Legrand 2+8 wayLEGRAND |
289 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
290 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& |
291 | 8 WAY SPN MCB PDB at CONFERENCE&REST RMS FF OFFICE DB15 FOR AC DB15 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed In wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection With suitable size ofcopper wire and neutral link & provision for earthing attachment. Enclosure (607711) Legrand 2+8 way LEGRAND. |
292 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBS and necessary connection.Legrand DP 63A |
293 | Supplying and fixing 240/415 V MCB of Breakingcapacity 100kA & C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A |
294 | 8WAY SPN MCB LDB at GOOMTI 2 DB16 Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for Enclosure (607711)Legrand 2+8 way LEGRAND |
295 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
296 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary Connection Legrand SP 6-32A |
297 | 8WAY SPN MCB LDB at GOOMTI1 DB8 8 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthing attachment. Enclosure (607711) Legrand 2+8 way LEGRAND |
298 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Legrand DP 40A |
299 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA& C characteristics on din rail of existing DBs and necessary connectionLegrand SP 6-32A |
300 | SUPPLY OF BULK LIGHT PHILIPS MAKE WT202W LED6S NW PSU S2 PC |
301 | Fixing of Bulk head fitting on wall |
302 | Supplying of 25W circular CFL DECOTWIST(Philips Cat no Deco Twist Ridge BCS 1901) |
303 | Fixing of 25W circular CFL DECOTWIST(Philips Cat no Deco Twist Ridge BCS 1901) |
304 | Supplying of Exhaust fan 23cm sweep (Make-EPC) |
305 | Fixing exhaust fan after damages and smooth cement finish etc as practicable as possible and providing necy length PVC insulated wire and making connection for Exhaust fan of dia 23 cm |
306 | Fixing only louver shutter/cowl on wall with necy, Bolts& nuts (6mmx62mm long) for 23 cm exhaust fan. |
307 | Supplying of 1200 mm sweep Ceiling without regulator (Make Crompton/Orient) |
308 | FIXing only ceiling fan complete with blades,canopy,fork, rubber bush, etc incl S&F connecting wire(2x1.5 sqmm flexible copper Wire) for down rod upto 30cm incl.painting the rod with approved paint and making necessary connection as required. |
309 | FAN CLAMPS Supplying &Fixing MS fan clamp of two piece type for RC ceiling as per approved specification , fabricated from 40mmx9mm MSS flat including making good the damage s to building roof with satifactory finishing and painting |
310 | Supplying &Fixing electonic step regulator of make Anchor for 1200 mm Celing fan in the prelaid SB for lights and fans |
311 | Supplying &Fixing of250V AC Buzzer (Make-Anchor-8217) on onHW boardon wallinclS&FHW board |
312 | Wiring in 1.1KVgrade single core stranded `FR" PVC insulated & unsheathed copper wire (approved make) of following sizes in suitable sizePVC casing-capping (Precision make) incl. necy PVC clips,fittings etc. 2x36/0.3(2.5 sq mm )+1x22/0.3(1.5 sq mm ) |
313 | Supplying & Fixing composite flush type250V 3pin 15A plug socket with 15A Piano key type (Anchor)switch on sheet metalboxwith bakelite top cover and earthing attachment incl S & F sheet metal box 175mmx100mm of16SWG with bakelite top cover3 mm thick |
314 | WIRING (Surface)(from DB to 16A Switch Board and from 16A switch board to Bulk head fittings)forstaff quarters buildings for group controlof 5 nos of light fittings Wiring with 1100 Volt grade 3 core 2.5 sqmm copper conductorpvc insulated (Havells/Nicco) armoured cable withms saddles/clamps etc including supply and fixing of 16A piano key type switch on MS box with cover and painting |
315 | Distribution board with IP-42/43 protection, concealedin wall after cutting the wall & mending good thedamages to original finish incl. Inter connection withsuitable size of copper wire and neutral link & provisionor earthing attachment MAKE Legrand 8 way Enclosure (607717) |
316 | Group control operation of the street/security lights by installing 1 x 10A SPN MCB (C-Series, 240V, 10KA, Havell"s make) and 1 x 2.0/1.5 KW LT make1.0 Ph DOL starter Type MF1 in a 16 SWG MS sheet metal enclosure including painting and installation on the iron leg on wall after completing the inner connection. |
317 | Supplyingand fixing rigid pvc pipe/polythene pipeof size 19mm bore,3mm thickcomplete with fitting as necy under ceiling/beam/over false ceiling ,bound with 22SWG GI bindingwire incl supplying and drawing 1x18 SWGGIwire as fish wire inside the pipes fittings and providing 50mm dia disc of ms sheet (20SWG) having colour paintat one facefastened at the load point end of polythene pipe with fish wire (synchronising with roof/beam casting work of building de PWD SCHEDULE NOV2017item no1bpage -E-2 |
318 | Cutting channel of 40 mm x 40 mm size on masonry wall incl.S&F heavy gauge polythene pipe dia as stated below, bymeans of iron hooks and supplying and drawing 18 SWG GIWire as fish wire incl. mending good damages to building works(a)19 mm dia 3 mm thick polythene pipe without earth continuity wire vide |
319 | Supplying and Drawing 1.1 KV single core stranded "FR"PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) of the following sizes in the prelaidpolythene pipe and by the prelaid GI fish wire and making necy. connection as required2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC |
320 | Supplying of A/C Power Units( North West Cat no ACPU 6M -BT) flush type with DP MCB,Single Phasestarter with overload relay 11-18 A range,25A socket& plug with indicating lamp complete with PVC Modularbox for 1.5 T A/C Make North West |
321 | Fixing of A/C Power Units for 1.5 T A/C Make North West |
322 | GYSER POINT WIRINGSupplyingand fixingpolythene pipeof size 19mm bore,3mm thickcomplete with fitting as necyunder ceiling/beam ,bound with 22SWG GI bindingwire incl supplying and drawing 1x18 SWGGIwire as fish wire inside the pipes fittings and providing 50mm dia disc of ms sheet (20SWG) having colour paintat one facefastened at the load point end of polythene pipe with fish wire (synchronising with roof/beam casting work of building construction)vide PWD SCHEDULE NOV2017item no 1b page -E-2 |
323 | Cutting channel of 40mmx40mm size masonrywallincl S&F heavy gauge polythene pipe 19mm dia 3mm thick polythene pipewithout earth continuity wireby means of iron hooks and supplying and drawing 18 swg GI wire as fish wire incl mending good damages to building works . |
324 | Supplyingand Drawing1.1KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire(approved make) of the followingin prelaid polythene pipe and by the prelaid fishGI wireand making necy connection as required 2x36/0.3(2.5sqmm )+1x22/0.3 (1.5 sqmm ) as ECC |
325 | Supply ,Installation ,Testing & Commissioning of 16A modulartype Switch on separate board outside toilet and 16/6A modular typesocket with modular type front plate mounted on separate modular typeconcealed metal box mounted flushed on wal inside toiletlincluding all accessories ,.Make of switch/sockets,metal box,front plate etc -Crabtree/Legrand |
326 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC1 light point controlled by one way 6A switch av run 6M |
327 | wall fan6m av run |
328 | exhaust fan 6m av run |
329 | call bell point 6m av run |
330 | 1 light point controlled by TWOWAY way 6A switch ide PWD SCHEDULE NOV2017item no 2a page -E24 for 9M run |
331 | 6A SWITCH AND SOCKETDistn. wiring in 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC On Boardof light |
332 | av run 1.5m |
333 | av run 4.5m |
334 | Supplyingand fixingrigid pvc pipe/polythene pipeof size 19mm bore,3mm thickcomplete with fitting as necyunder ceiling/beam/over false ceiling ,bound with 22SWG GI bindingwire incl supplying and drawing 1x18 SWGGIwire as fish wire inside the pipes fittings and providing 50mm dia disc of ms sheet (20SWG) having colour paintat one facefastened at the load point end of polythene pipe with fish wire (synchronising with roof/beam casting work of building construction) |
335 | Cutting channel of 40mmx40mm size masonrywallincl S&F heavy gauge polythene pipe 19mm dia 3mm thick polythene pipewithout earth continuity wireby means of iron hooks and supplying and drawing 18 swg GI wire as fish wire incl mending good damages to building works |
336 | Supplyingand Drawing1.1KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire(approved make) of the followingin prelaid polythene pipe and by the prelaid fishGI wireand making necy connection as required2x36/0.3(2.5sqmm )+1x22/0.3 (1.5 sqmm ) as ECC |
337 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wirevide |
338 | Supply and fixing of ws with 3nos 6A switch sockets with wiringfrom RAW POWER SPN DBwith 2x2.5+1x1.5 sqmm pvc insulated copper wire concealed pvc pipe without 600VA UPS 240V ,50C/S A BUT WITH SUPPLY AND FIXING OFEXTENTION CORD WITH 4NOS 6A swich socket |
339 | SUPPLY& FIXING LIGHTS,FANS LIGHTS Supply and fixing of night lamps(led) 3W Philips makeor similar reputed make in metal box with transparent cover to be mounted recessed in wall |
340 | SupplyofRC366B LED33-5000 OD WHrecess mounted LED Luminaire (make -Philips) for2"x2" on false ceiling (43W) The price includes suply of lamps also. Equivalent Brand : Havells / Osram/Wipro |
341 | FIXING ofRC366B LED33-5000 OD WHrecess mounted LED Luminaire (make -Philips) 2"X2"recessed infalseceiling (43W) |
342 | Supplyofrecessedmounted BBS1701XDLED -5000 PSU WHround DOWN LIGHTER,15W (make -Philips) LEDLight FixturesThe price includes suply of lamps also.Equivalent Brand : Havells / Osram/Wipro |
343 | FIXINGofrecessedmounted BBS1701XDLED -5000 PSU WHround DOWN LIGHTER,15W (make -Philips) LEDLight Fixtures |
344 | Supplyofrecessedmounted 3x1W (make -Philips) LEDWHITE Light30692 40K 12 NC NO 91500394701 FixturesThe price includes suplly of lamps also.Equivalent Brand : Havells / Osram/Wipro |
345 | FIXING ofrecessedmounted 3X1W (make -Philips) LEDWHITE Light30692 40K 12 NC NO 91500394701 Fixtures |
346 | Supplyingof Philips make slim line LED TUBE 18W appr length 4" complete on wallnecessary materials and wiring |
347 | FIXING only single/double tube light fitting complete with all accessoriesdirectly wall/ceiling by screws |
348 | Supplyingof Philips make slim line LED TUBE9 W appr length 2" complete on wallwith necessary materials and wiring |
349 | FIXING only single tube light fitting complete with all accessoriesdirectly wall/ceiling by screws |
350 | SUPPLY ofsurfacemounted round fitting with 7W (make -Philips) LEDllamp |
351 | Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener for 7w LEDLIGHT |
352 | EXHAUST FAN Supplying of Exhaust fan 30 cm sweep (Make-EPC) with louver shutter |
353 | Fixing exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possibleandproviding necylengthof PVC insulated wireand making connection for exhaust fan of dia 30 cm |
354 | Fixing only louver shutter /cowl with necy bolts,nuts(6mm dia x62mm long for 30cm exhaust fan |
355 | CALL BELL &BELL PUSHSupplying &fixing of AC/DC superior type DING DONG Call Bell (Anchor) on HWboardincl. S&FHW board |
356 | Supplying & FixingBELL push on board |
357 | WALL FAN Supplyof wall fan400 mm sweep makeCROMPTONcomplete with regulator, etc., |
358 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20PVC insulated flexible copperwire 0.5 mt. length |
359 | Sub Total |
360 | GST 12% |
361 | CESS 1% |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail