Internal Electrical Works For Block Public Health Unit For Bangitola R.H Kaliachak-Ii Block, Malda.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Jun 2022
0 days left
EMD
15000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kaliachak → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Internal Electrical Works For Block Public Health Unit For Bangitola R.H Kaliachak-Ii Block, Malda.
BOQ
| Sl. No. | Item Description |
| 1 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish i)Average run 8 mtr |
| 2 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper condutor single core cable in surface / recessed PVC conduit 2 way modular switch,modular plate,suitable GI box and earthing the point with 1.5 sq.mm .FRLS PVC insulated copper conductor single core cable etc as required. |
| 3 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.b) 3 x 22/0.3 (1.5 sqmm) |
| 4 | s)2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 5 | v)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC |
| 6 | y) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC |
| 7 | g1) 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC [UPS] |
| 8 | Supplying and fixing polythene pipe complete with fittings as necy.. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction).b)19mm dia 3mm thick Polythene Pipe |
| 9 | c)25mm dia 3mm thick Polythene Pipe |
| 10 | d) 32mm dia 3mm thick Polythene Pipe |
| 11 | Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI \"U\" hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.6a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire |
| 12 | Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI \"U\" hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles,.7a)25 mm dia 3 mm thick polythene pipe without earth continuity wire |
| 13 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. a)100 mm x 100 mm x 65 mm |
| 14 | b)150 mm X 100 mm X 65 mm |
| 15 | c)415 mm X 200 mm X 65 mm |
| 16 | Supply & Fixing Bakelite / Perspex top cover on existing Inspection board by Brass screws. a)100 mm x 100 mm x 65 mm |
| 17 | b)150 mm X 100 mm X 65 mm |
| 18 | c)415 mm X 200 mm X 65 mm |
| 19 | Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy.. PVC fittings etc. and mending good damages to building works. a).20x10mm Size |
| 20 | 25x10mm Size |
| 21 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. i)On Board |
| 22 | Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Separate 6A Plug Point] |
| 23 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [CPU Board] |
| 24 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required [CPU Board] |
| 25 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Separate 16A Plug Point] |
| 26 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [CPU Board] |
| 27 | Supply & Fixing 240 V 16 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required [CPU Board] |
| 28 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [AC Socket Board] |
| 29 | Supply & Fixing 240 V, 20A/25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Brand approved by EIC) type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Autoclav & Biochem Analyzer Board] |
| 30 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc [AC Starter Board] |
| 31 | Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 12 Module GI Modular type switch board with 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Separate 6/16A Board] |
| 32 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [AC Socket Board] |
| 33 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.(a) 2 Module |
| 34 | (b) 4 Module |
| 35 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. (f) 2 Row 18 Module ( for CPU Board--3 Nos. 6A 5 Pin Socket with Switch+1 No. 16A Socket With Swich) |
| 36 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand / Havells / Siemens). 8 way |
| 37 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand / Havells/Siemens). 6 way |
| 38 | 8 way |
| 39 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 4 Way |
| 40 | Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachmenta) 6 Way Horizontal |
| 41 | b)8 Way Horizontal |
| 42 | c)8 Way Vertical |
| 43 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (Legrand / Havells/Siemens). 160 A [Make-Legrand/Siemens/Havells] [VTPN I/C] |
| 44 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Havells / Siemens).6 amps to 32 ampsa)Single pole 6-32A |
| 45 | b)Four pole 6-32A |
| 46 | c)Triple Pole 20A [[VTPN O/G] |
| 47 | d)Triple Pole 40A [VTPN O/G to UPS] |
| 48 | e)Triple Pole 63A [VTPN O/G to NDB 1,2] |
| 49 | f)TPN MCB 40A [EDB I/C] |
| 50 | g)TPN MCB 63A [NDB 1,2 I/C] |
| 51 | Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nutsbolts etc (L&T/Havells/HPL) 160A |
| 52 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 53 | Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. |
| 54 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessaryconnection as required by 2x1.5 sqmm flexible copper wire. |
| 55 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 30 cm (12\") |
| 56 | Supply & Fixing louver shutter on wall with necy.. bolts & nuts (6 mm dia x 62 mm long) a) For Al :30 cm Exhaust fan (12\") |
| 57 | Supplying & Fixing 240 V AC Buzzer (Ancho) on HW board incl. S&F HW board |
| 58 | a) Supply of Fans : Supply of 48 inch sweep ceiling fan Similar to --Crompton Greaves make (UD & MA Page-23 item no-70) |
| 59 | b)Supply of Fans :Supply of 12inch sweep heavy duty exhaust fan Similar to-Crompton Greaves make (UD & MA Page-14 item no-5) |
| 60 | Laying on Wall / surface with Saddles / clamps Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting |
| 61 | CABLE TERMINATIONSupplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a) For 3½ core upto 35 sqmm |
| 62 | b) For 3½ core upto 50 sqmm |
| 63 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials a) 3½ core 35 sqmm cable |
| 64 | b) 3½ core 50 sqmm cable |
| 65 | a) Supplying of 1.1 KV. Grade PVC insulated conductor of following cables (make: Polycab/Gloster/Havells) 35 sqmm3½ core |
| 66 | b) Supplying of 1.1 KV. Grade PVC insulated conductor of following cables (make: Polycab/Gloster/Havells) 50 sqmm3½ core |
| 67 | EARTHING: Soil Excavation :Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil |
| 68 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By TATA-Medium GI pipe |
| 69 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 70 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode |
| 71 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 72 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. a) Solid GI wire. No. 8 SWG |
| 73 | b) Solid GI wire. No. 6 SWG |
| 74 | SOCKETSupply & Fixing RJ45 sitable for CAT6 cable (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required |
| 75 | SOCKET Supply & Fixing Telephone socket (RJ11) Modular type (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required. |
| 76 | GI BOX Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages tobuilding works (a) 4 Module |
| 77 | CABLE Supplying & Drawing 2-pair Telephone cables with high density polyethylene insulated solid annealed high conductivity bare copper of dia 0.5mm in prelaid PVC rigid conduit / in polythene pipe embeded in wall. |
| 78 | Supplying & Drawing LAN cable (CAT6) (Brand approved by EIC) in prelaid PVC rigid conduit/ in polythene pipe embeded in wall. |
| 79 | Supplying and fixing of the following sheet steel clad wall / recess mounting telephone tag blocks of krone make constructed from 14 SWG sheet steel finished with red oxide coating of two coats of paint with hinged gasketted powder coated door and complete.a) 05 pairs |
| 80 | b) 15 pairs |
| 81 | Supplying of LED Batten light fitting (Philips make, model - BN021C LED20S PSU CW GR S2 (KMDA Vetted) |
| 82 | Supply & Delivery at site 15 watt LED Bulb (Philips/havells make model-New Adore 15W E27 CDL Ball Lamp), as per direction of EIC. (Analysed rate) [KMDA Vetted] |
| 83 | Supplying of 36watt LED Outdoor Type Luminiares along with all accessories complete as required.(Similar to Philips-model no- BRP046 LED 36W MR SI PSU) (Approved Rate) |
| 84 | Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener |
| 85 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 86 | Fixing only lamp |
| 87 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 88 | WBSEDCL Service change |
| 89 | Applicable GST @ 12% |
| 90 | Labour wellfare CESS @ 1% |
AI Tender Summary
Tender Timeline
May 19, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJun 03, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJun 06, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender