}

Niq For Minority Residential Niq For Minority Residential School Margo Munda, Deoghar , Phartiha, Garhwa District. Barhate, Sahebganj District NAME OF WORK :- .(3.) Construction of School with Residential Building for Minority community at Margo M, deoghar-Jharkhand

Jharkhand State Building Construction Corporation Limited has published Niq For Minority Residential Niq For Minority Residential School Margo Munda, Deoghar , Phartiha, Garhwa District. Barhate, Sahebganj District NAME OF WORK :- .(3.) Construction of School with Residential Building for Minority community at Margo M. Submission Date for this Tender is 24-05-2022. Footwears Tenders in deoghar Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

32287667
Niq For Minority Residential Niq For Minority Residential School Margo Munda, Deoghar , Phartiha, Garhwa District. Barhate, Sahebganj District NAME OF WORK :- .(3.) Construction of School with Residential Building for Minority community at Margo M
Open Tender
Indian
Jharkhand
deoghar
24-05-2022

Tender Details

Niq For Minority Residential Niq For Minority Residential School Margo Munda, Deoghar , Phartiha, Garhwa District. Barhate, Sahebganj District NAME OF WORK :- .(3.) Construction of School with Residential Building for Minority community at Margo Munda, Deoghar District.(4.) Construction of School with Residential Building for Minority community at Phartiha, Garhwa District.(6)PROPOSED CONSTRUCTION OF RESIDENTIAL SCHOOL FOR MINORITY GROUP AT BARHATE, SAHIBGANJ, JHARKHAND MR Fabrication, Supplying, Installation, Testing & Commissioning of electrical control panel of cubical construction, wall mounted type, fabricated out of 2mm. thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection, and accessories mounting and internal wiring, earth terminals, numbering etc. complete in all respects, suitable for operation on 415 V, 3 phase 50 HZ AC supply with enclosure protection class IP 42. For Terrace Pump MR Fabrication, Supplying, Installation, Testing & Commissioning of electrical control panel of cubical construction, wall mounted type, fabricated out of 2mm. thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection, and accessories mounting and internal wiring, earth terminals, numbering etc. complete in all respects, suitable for operation on 415 V, 3 phase 50 HZ AC supply with enclosure protection class IP 42. For Terrace Pump MR Supplying fitting fixing Pressure Gauge Assemble with Gate/Ball Valve all complete with labor and material as per engineer in charge. MR Supplying fitting fixing Air release Valve / Drain Valve all complete with labor and material as per engineer in charge. MR Supplying fitting fixing MS Structure support for piping all complete with labor and material as per engineer in charge. MR Supplying and fixing of hose cabinet of size 450mm x 450mm x 250mm made of 2mm thick M.S. sheet with 6mm thick glazed glass door including necessary locking arrangment suitable to accomodate 1 nos. 15 mtr. long hose pipe, 1 no. branch pipe mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect. MR Providing , fixing Dry Chemical Powder (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 20oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (4 Kg Capacity) MR Stainless Steel Text (Text Height 250 mm ) at Pergola Slab with Grouting all Complete Including matrial & Labour as pet E/I MR Carbon Di-oxide Type , Gas Confirming to IS ‘15222’ , Cylinder Confirming to ‘IS 7285’ & PESO approved ,Controllable Discharge Mechanism, Discharge Hose & Horn As per ‘IS 15683’ & ‘IS 2878’ ISI mark Fire Extinguishers (Wheel Type or Squeeze Grip Type). Operating Temperature :- (-)20oC to (+)55oC Suitable for ‘B’ ‘C’ Class of FIRE (4.5 Kg Capacity) MR Providing , fixing Modular type Fire Extinguishers for electrical rooms (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 10oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (5 Kg Capacity) MR Providing and fixing 25 mm nominal gun metal gate valve class I with CI wheel of approved quality with union (Screwed end) MR Main LT Panel for Main Building :- Supplying, designing, manufacturing, installation, testing and commissioning of LT Panel of 14 SWG CRCA sheet (2 mm) steel , dust and vermin proof with reinforcement of suitable size iron channel , with proper lifting arrangement effecting proper connection of all incomers and outgoing(IP-43) fully compartmentalized cubical type, floor mounted , totally enclosed, extendable on both sides, switch board and suitable for operation on 415V, 50Hz, 3 Ph. AC supply and fault level 50 kA with front operated construction including separate fabrication arrangement for fixing MCCBs and Bus Coupler. The sheet steel under go minimum 7 tanks treatment followed by finishing powder coating of minimum 60 micron thickness duly compartmentalized having accessories mounted inside the cubical panel, earthing with 2 Nos. earth studs.The panel includes 415V, 200A, 3Ph, 50kA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) Aluminium, Earth Bus for main supply, removable glands plates, cable glands and sending and receiving ends, including connection with outgoing Feeders complete in all respects. All inter connections shall be made with 2.5 4, 6, 10 Sq mm PVC Cu. wire. Main LT Panel for Main Building :- Supplying, designing, manufacturing, installation, testing and commissioning of LT Panel of 14 SWG CRCA sheet (2 mm) steel , dust and vermin proof with reinforcement of suitable size iron channel , with proper lifting arrangement effecting proper connection of all incomers and outgoing(IP-43) fully compartmentalized cubical type, floor mounted , totally enclosed, extendable on both sides, switch board and suitable for operation on 415V, 50Hz, 3 Ph. AC supply and fault level 50 kA with front operated construction including separate fabrication arrangement for fixing MCCBs and Bus Coupler. The sheet steel under go minimum 7 tanks treatment followed by finishing powder coating of minimum 60 micron thickness duly compartmentalized having accessories mounted inside the cubical panel, earthing with 2 Nos. earth studs. The panel includes 415V, 200A, 3Ph, 50kA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) Aluminium, Earth Bus for main supply, removable glands plates, cable glands and sending and receiving ends, including connection with outgoing Feeders complete in all respects. All inter connections shall be made with 2.5 4, 6, 10 Sq mm PVC Cu. wire.All incomer MCCB and bus coupler shall be mechanically operated . All 4 pole MCCB with thermomagnetic based release must have following character: Icu=100% Ics with adjustable S/C and O/LProvision for inbuilt earth leakage module & provision for inbuilt measuring unit. The panel consisting of the followings, 4 pole MCCB 160 A, 35 kA with fixed thermal magnetic setting- 1 no, Provision of Mechnical interlocking between 125A/FP/25KA MCCB as common incoming and 1 No. of 125A on load Change over for D.G incomer, in such a way so that the two supplies are not parallel at any time.1 No. 125A TPN on load Change over panel mounted open execution type and suitable bus arrangement for Cable termination. Make- L&T/Sucomo. 1 No. 125A/FP/16kA/ MCCB thermomagnetic release type, and S/C, O/L protection, with Rotary Handle & Spreader links. MCB TPN 40A- 10 nos, MCB DP 40A- 2nos( oter light+Spare), MCB DP 63A- 6 nos( PDB+UPS+Spare),Electronic On timer delay -30 sec, 200 amp 415 V heavy duty three phase with neutral busbar chamber, Indicator switch- 3 nos, Selector switch, Analog Voltmeter-3 nos, Analog Ameter, C.T. Coil MR Main LT Panel for Hostel Building :- Supplying, designing, manufacturing, installation, testing and commissioning of LT Panel of 14 SWG CRCA sheet (2 mm) steel , dust and vermin proof with reinforcement of suitable size iron channel , with proper lifting arrangement effecting proper connection of all incomers and outgoing(IP-43) fully compartmentalized cubical type, floor mounted , totally enclosed, extendable on both sides, switch board and suitable for operation on 415V, 50Hz, 3 Ph. AC supply and fault level 50 kA with front operated construction including separate fabrication arrangement for fixing MCCBs and Bus Coupler. The sheet steel under go minimum 7 tanks treatment followed by finishing powder coating of minimum 60 micron thickness duly compartmentalized having accessories mounted inside the cubical panel, earthing with 2 Nos. earth studs. The panel includes 415V, 200A, 3Ph, 50kA, 50Hz Electrolytic Aluminium Bus Bar (E91EWP) Aluminium, Earth Bus for main supply, removable glands plates, cable glands and sending and receiving ends, including connection with outgoing Feeders complete in all respects. All inter connections shall be made with 2.5 4, 6, 10 Sq mm PVC Cu. wire.All incomer MCCB and bus coupler shall be mechanically operated . All 4 pole MCCB with thermomagnetic based release must have following character: Icu=100% Ics with adjustable S/C and O/LProvision for inbuilt earth leakage module & provision for inbuilt measuring unit. The panel consisting of the followings 4 pole MCCB 160 A, 35 kA with fixed thermal magnetic setting- 1 no 1 No. 125A TPN on load Change over panel mounted open execution type and suitable bus arrangement for Cable termination. Make- L&T/Sucomo. 1 No. 125A/FP/16kA/ MCCB thermomagnetic release type, and S/C, O/L protection, with Rotary Handle & Spreader links. MCB TPN 40A- 10 nos, MCB DP 40A- 6nos( outer light+Spare) , MCB DP 63A- 4 nos( UPS+Spare), Electronic On timer delay -30 sec , 200 amp 415 V heavy duty three phase with neutral busbar chamber , Indicator switch- 3 nos , Selector switch, Analog Voltmeter-3 nos, Analog Ameter, C.T Coil MR SITC of 24x ports 10/100/1000BASE-T Ports,4x 1G SFP ports, Supports PoE Standards IEEE 802.3af, 802.3at,1x USB-C Console Port,1x USB,Up to 370 W of Class 4 PoE Power, Fanless Design, with Dual Core ARM Cortex A9 @ 1016 Mhz CPU, Memory-4 GB DDR3 16 GB eMMC , Packet Buffer Size of 12.38MB (4.5MB Ingress/7.875MB Egress),IPv6 Ready Certified MAC address table size: 16000 entries;Average Latency-1 GbPs Latency: < 1.5 µs (LIFO 64-byte packets), Throughput: up to 41.6 Mpps (64-byte packets), Switching capacity: 56 Gbps, Operating Temperature 32°F to 113°F (0°C to 45°C) up to 5000 ft (1.5 km), Certifications-UL,EN,FCCI, Preferred Make- HP/Aruba/Allied Telesis/Cisco/Netgear or as approved by E/I MR SITC of 12x ports 10/100/1000BASE-T Ports,2x 1G SFP ports,2x 1GbE ports , Supports PoE Standards IEEE 802.3af, 802.3at,1x USB-C Console Port,1x USB,Up to 139W of Class 4 PoE Power, Fanless Design,with Dual Core ARM Cortex A9 @ 1016 Mhz CPU, Memory-4 GB DDR3 16 GB eMMC , Packet Buffer Size of 12.38MB (4.5MB Ingress/7.875MB Egress),IPv6 Ready Certified MAC address table size: 16000 entries;Average Latency-1 GbPs Latency: < 1.5 µs (LIFO 64-byte packets), Throughput: up to 23.8 Mpps (64-byte packets), Switching capacity: 32 Gbps, Operating Temperature 32°F to 113°F (0°C to 45°C) up to 5000 ft (1.5 km), Certifications-UL,EN,FCCI, Preferred Make- HP/Aruba/Allied Telesis/Cisco/Netgear or as approved by E/I MR SITC of 24 port UTP jack panel (24 port RJ-45 Loaded CAT-6 UTP 19 rackmountable patch panel preferbaly with 6 blocks). (Make:Legrand/Panduit/RIT/Siemon) Detailed Specs for 19 1U 24 port unsheilded, Patch Panel Patch panel should be modular design, populates up to 24 UTP keystone-type jacks in 1U, Patch panel should be Enhanced with cable strain relief with retention tray; It should be single metal both front panel and rear tray, Material: sub-rack made of MS Steel with dimension 44.4 mm : 482.6 mm : 105 mm (h:w:d) tray, Information Outlet or connectin module should comply with the specification mentioned above in 2, Standard : Conforms to IEC-60603-7 (603-7) for keystone-type, snap-on apertures, Should be RoHS complied MR SITC of Straight LAN Patch Chord-1 Mtr (Make:Legrand/Panduit/RIT/Siemon) ,Detailed Specs for Patch Cord, U/UTP 4P, Cat.6, length  1/3 Metre, Standardization: Compliant with Cat.6, Class E requirements: ISO/IEC 11801 2nd Edition Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5 , Cable shield:  U/UTP, Number of conductors : 8 , Stranding: 7 x 0.20 mm (24 AWG), Cable jacket characteristics: cable, metal-free Cable overall diameter: 6.5±0.2 mm, Tube / Wire type: stranded conductor, Insulation: solid polyolefin, 0.97±0.02 mm diameter ,Plug: Feature cable retension, with enhanced pull strength., Cat 6 patch cord plug to have round cable holder and strain relief boot to avoid bending. Jacket: PVC with 8 different color options,Plug should have high repeatability cross talk performance MR SITC of Fully Loaded 9U 19 600*500 Wall Mounted Rack with all required accessories -2 Nos. of Fan,6A 6 Plug PDU-1 Nos. ,Cable Manager-2 Nos., Mounting Screws-20 Pcs ; Preffered Make-Legrand/APW/President/Valrack/Netrack MR SITC of EPABX SYSTEM: IP based 100% non-blocking EPABX System should be a IP Compatible with rich feature set of the system and can be connected with pure Voice over IP (VoIP) communication network across corporate Local and Wide Area Networks (LAN and WAN) as & when required. Central Processing Unit: The system main software should be open architecture based. The CPU of main system shall be 32 bit processor working at 2.0 GHz or better. The system should be Wall mountable. • System Architecture should be latest pure IP and should be wall Mountable; Meet-me conference 30 party X 2 from day 1 must be available. Must Support Unified Communications Equipped with 16 Analog Extensions expandable upto 48 Extensions,4 Analog Trunk Ports,EPABX Make: Avaya/NEC/Unify MR Analog Basic Push Button Telephone: SITC of analog telephone- Make: Panasonic/ BPL/Beetel MR SITC of Telephone Tag Block): IP-65( weather proof). Preffered Make-Krone 50 pair krone Box fully loaded without IPM MR Supply, fitting, fixing, commissioning and testing of 16 Sq. MM Copper Conductor Multi strand PVC Sheilded FRLS Wire with suitable Copper LUGS for Battery Interconnection and suitable 16 Sq. mm copper wire of 2 length of 10 mtrs each for UPS to Battery excluding cable from PANEL to UPS and UPS to panel. Make- Polycab/Havells/KEI MR Chemical Earthing:-Supply, errection, fitting, fixing, commissioning and testing along with earth cutting, digging, earth refilling for chemical earthing of the building except G.I. Strips (25mmX5mm) Each earth pit has to be tested with earth tester 1000 V/1000 Ohms & the test report has to be submitted by the contractor to the department after certification of the same by the consultant. The above chemical earthing includes the provision of masonary enclosure and HDPE Earth Pit Cover 300mm X 300 mm (Under-floor earth inspection pit) having locking arrangement as earth chamber.The above chemical earthing includes the following items (3 Mtr Earthing) ; Each chemical earthing shall have following details:- Supply of Pollution free Earthcon Compound 4 bags of 25 Kg each ; Supply of 17.2 mm dia, 250 micron,molecularly bounded copper coated 3 Mtr long electrode. Tested as per IEC 62561-2. Meets the requirement of IS 3043 & IEC 60364-5-54. Tested for short circuit withstanding capacity. High Tensile strength. (UL Listed).; Supply of Stainless Steel U Bolt Clamp; Supply of HDPE Earth Pit Cover for earth chamber (Capacity of 5 ton) ; Sub-total-C( UPS System & Accessories) MR SITC of 5MP Fixed Lens Network Bullet Camera with following Technical Specifications; Preffered Make: Honeywell/Bosch/Hikvision/Pelco/Sony Image Sensor :- 1/2.7 Progressive Scan CMOS, Min. Illumination :- Color: 0.003 Lux @ (F1.4, AGC ON), B/W: 0 Lux with IR Preferred recording Resolution:- 5MP (2592x1944) or better ,Day & Night:- IR Cut Filter , Shutter speed:-1/3 s to 1/100,000 s, Digital Noise Reduction;- 3D DNR ,WDR:- 120dB True WDR or better, Lens;- 4mm , IR range :- 40m IR or higher ,Streaming Type:- Should Support quad video streams or better ,Video Compression:- H.265,H.264, H.264+,H.265+,MJPEG and Main stream supports H.264+/H.265 , Audio Compression:- G.711ulaw/G.711alaw/G.722.1/G.726/MP2L2/PCM/MP3 , Image Enhancement:- BLC, HLC, 3D DNR, EIS, Defog,ROI , (5 fixed regions for main stream and sub-stream). Image settings:- Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser , Day/Night Switch:- Day, Night, Auto, Schedule , Network Protocol :-TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, NTP, UPnP, SMTP, IGMP, 802.1X, QoS, IPv4, IPv6, UDP, Bonjour, SSL/TLS, PPPoE, ARP, SNMP,Open Network Video Interface (PROFILE S, PROFILE G, PROFILE T),ISAPI. Simultaneous Live View:- 6 channelUser Host:- 32 users. 3 user levels: administrator, operator and userSecurity:- Password protection, complicated password, HTTPS encryption, IP address filter, Security Audit Log, basic and digest authentication for HTTP/HTTPS, TLS 1.2, WSSE and digest authentication for Open Network Video Interface, memory card encryption.Edge base Recording storage:-Built-in memory card slot, support microSD card, up to 256 GB ,Preferable analytics features:- Motion detection, video tampering alarm, Line crossing detection, intrusion detection,scene change detection, video quality diagnosis.Event Alarm:- Notify surveillance center, trigger recording, trigger capture, send email, audible warning,network disconnected, illegal login.Ethernet Port:-1 x RJ45 10M/100M Ethernet port, Audio interface;- 1x input, 1x output , Power Supply:- DC12V, PoE (802.3af) , Operating Conditions:- -30° C ~ + 60° C Ingress Protection:-IP67 , Certifications:- CE, FCC, UL,BIS. MR SITC of 32 Channel NVR Processor : Dual-core embedded processor, Operating System : Pre-loaded Licensed OS,IP Camera Support Up to 32-ch , should support H.265+/H.265/H.264+/H.264 video formats, Up to 2-ch @ 8MP or 4-ch @ 4MP or 8-ch @ 1080P decoding capacity,1 HDMI and 1 VGA interfaces: both interfaces support independent video output,4 HDDs for continuous video recording, Up to 256 Mbps incoming bandwidth, Outgoing Bandwidth-160 Mbps, Audio Output-1-ch, RCA (2.0 Vp-p, 1 KΩ, using the audio input ),Two-Way Audio 1-ch, RCA (2.0 Vp-p, 1 KΩ, using the audio input ),Video Output Mode-HDMI/VGA independent output, Recording Resolution-12 MP/8 MP/6 MP/5 MP/4 MP/3 MP/1080p/UXGA/ 720p/VGA/4CIF/DCIF/2CIF/CIF/QCIF,SATA-4 SATA interfaces of Capacity Up to 10TB capacity for each HDD, Serial Interface-2 RS-485 (half-duplex), 1 RS-232, USB Interface Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Smart Phone Connectivity through app or browser : iPhone, iPad, Android, Windows Phone, Should Support- multiple VCA (Video Content Analytics) events, Configurable special camera smart functions, such as VCA detection (motion, line crossing, intrusion, etc.), heat map, ANPR, and people counting Power SITC : AC 100V~240V, 50/60Hz,Regulatory : CE, FCC,UL and RoHS; Preferred Make: Honeywell/Bosch/Hikvision/Pelco/Sony MR SITC of 16 Channel NVR Processor : Dual-core embedded processor, Operating System : Pre-loaded Licensed OS,IP Camera Support Up to 16-ch , should support H.265+/H.265/H.264+/H.264 video formats, Up to 2-ch @ 8MP or 4-ch @ 4MP or 8-ch @ 1080P decoding capacity,1 HDMI and 1 VGA interfaces: both interfaces support independent video output,4 HDDs for continuous video recording, Up to 256 Mbps incoming bandwidth, Outgoing Bandwidth-160 Mbps, Audio Output-1-ch, RCA (2.0 Vp-p, 1 KΩ, using the audio input ),Two-Way Audio 1-ch, RCA (2.0 Vp-p, 1 KΩ, using the audio input ),Video Output Mode-HDMI/VGA independent output, Recording Resolution-12 MP/8 MP/6 MP/5 MP/4 MP/3 MP/1080p/UXGA/ 720p/VGA/4CIF/DCIF/2CIF/CIF/QCIF,SATA-4 SATA interfaces of Capacity Up to 10TB capacity for each HDD, Serial Interface-2 RS-485 (half-duplex), 1 RS-232, USB Interface Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Smart Phone Connectivity through app or browser : iPhone, iPad, Android, Windows Phone, Should Support- multiple VCA (Video Content Analytics) events, Configurable special camera smart functions, such as VCA detection (motion, line crossing, intrusion, etc.), heat map, ANPR, and people counting Power SITC : AC 100V~240V, 50/60Hz,Regulatory : CE, FCC,UL and RoHS; Preferred Make: Honeywell/Bosch/Hikvision/Pelco/Sony MR SITC of 6TB Surveillance Grade Hard Disk for NVR for 30 Days Back up; Make-Seagate/WD MR 43 4k LED Panel,Preffered Make-LG/Samsung/Panasonic MR Supplying and fixing of hose cabinet of size 450mm x 450mm x 250mm made of 2mm thick M.S. sheet with 6mm thick glazed glass door including necessary locking arrangment suitable to accomodate 1 nos. 15 mtr. long hose pipe, 1 no. branch pipe mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail