Health and Family Welfare Government Departments Closing in 0 days TDR #32282532

Wbhf / Cms / Hst / 1P-114-2022 / Si-Rt ( 178 ) / 2022 / 198 / Group-Iii Re E Tender For Procurement Of Some Items For Two Years From The Date Of Award Of Contract ( Aoc ) , Diathermy, Short Wave Diathermy Unit ( Continuous And Pulsed ) Technical

Issued by Government Departments · kolkata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
15 Jun 2022
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Wbhf / Cms / Hst / 1P-114-2022 / Si-Rt ( 178 ) / 2022 / 198 / Group-Iii Re E Tender For Procurement Of Some Items For Two Years From The Date Of Award Of Contract ( Aoc ) , Diathermy, Short Wave Diathermy Unit ( Continuous And Pulsed ) Technical Specification: Output Of 400 To 500W In Continuous Mode And 800 To 1100 W In Pulse Mode Pulse Repetition Frequency Of 20 To 200 Hz Adjustable In 10 Steps Lcd Screen Display Of Parameter Treatment Timer With All Standard Accessories Condenser Pad With Cable Dis Electrodes With Arms And Cables. Patient Safety Switch. , Vdrl Shaker Table / Bench Top Centrifuge For Vdrl Shaker With 16 Socket : 1. Capacity 16X15ml. 2. Built In Time And Speed Regulator With Suitable Speed Indication And Lid Lock System. 3. Rpm 5000 To 6000 Rpm. 4. Power Supply 220 / 240 Volts, Single Phase, 50 Cycles Plus Minus 12 Ac. 5. A Line Voltage Corrector Of Suitable Rating Should Form Part Of The Configuration As Per Is. 9615 / 89. 6. Technical Literature The Firm Shall Submit Printed Illustrated Technical Literature / Leaflet Indicating The Model Number. If Quoted Model Is A Modified Version Of Their Any Standard Product That Also Be Indicated In The Offer. , Vdrl Shaker. 1. Feature For Rotating Slides For Vdrl Tests. 2. Specification Platform Size 300X300 Mm Spring Holder Which Can Accommodate Concave Slides Etc. 3. Rotation 180 Rpm Continuously Adjustable With Regulation. 4. Timer 0 To 30 Minutes For Control Of Shaking Duration With 1 Minute Interval. 5. Power Supply 220 - 240 Volts, 50 Cycles, Single Phase With Complete Chord And Plug. 6. Technical Literature The Firm Shall Positively Submit Printed, Illustrated Technical Literature / Leaflet Indicating The Model Quoted By Them. If Quoted Model Is A Modified Version Of Their Any Standard Product That Also Be Indicated In The Offer. , Ultrasound Therapy Unit ( Two Heads ) Technical Specification : Frequency Of 1 & 3 Mhz Intensity Of 0-3 W / Cm2 With Display Of Output Parameters Along With Timer And Two Water Proof Treatment Heads, One Large To 5 Cm Second Small Up To 1.0 Cm System Configuration Accessories Spares And Consumables : - All Standard Accessories Desired For Proper Functioning Of The Machine Jelly As Per Requirement. , Ventilator ( Specification As Per Nit Page Number 29-34 ) , Anesthesia Machine With Vaporizerrobust Structure Construction With Custom Aluminum Extrusions• & Formed Stainless Steel Work Surfacelarge Anti-Static Caster Wheels•Machine Should Be 3 Gas Delivery ( O2, N2o• & Air ) Systems With Pipeline Connections And Reserve Cylinder Yokesprovision To Mount Two O2• & One N2o Pin Indexed Cylinder With Gaugescolor Coded Ring Indexed Pipeline Fittings And Pressure Gauges For Each Gas•5 Tube ( Antistatic Coated ) Cascading Flow Meter Assembly With Back Lighting•Lever Operated Or Equally Effective Anti Hypoxic Device To Ensure Minimum 21% Oxygen Flow•Pneumatic Operated Oxygen Failure Alarm•Interlocking Mounting For Two Vaporizers•Pneumatic Audio• & Visual Alarm For Oxygen Failure When The Pressure Of The Gas Supply In The System Fails Below The Required Valueprovision To Cut Off Nitrous Oxide In Case Of Oxygen Failure•Main Switch For Switching On The System•3 Liter Oxygen Reservoir In Build The Main Unit•Non Return Valve Fitted To Back Bar To Protect Vaporizers From Back Pressure• 2Provision Of Patient Air Way Pressure Gauge•Three Numbers Of Storage Drawer Unit•Pin Indexed Yokes For Mounting 2 – Oxygen And 1- Nitrous Oxide Cylinders. Gauges To Be• Provided On The Front Panel With Color-Coding For Cylinder & Pipe Line Pressure.Auxiliary O2 Outlet With Flow Meter.•Overhead Monitor Shelf.•Common Gas Outlet With Emergency Oxygen Flush Button And 50 Cm / H2o Blow Off Valve•O2 Analysis ( Paramagnetic ) • Should Be Supplied With: Adult & Pediatric Brain Circuit, Circle Circuit ( Disposable ) , Pipeline Houses For O2, N2o & Air. Vaporizer- Isoflourane & Servoflourane .

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 24-May-2022 CORRIGENDUM-1 Date 15-Jun-2022
2 03-Jun-2022 CORRIGENDUM-2 Other 15-Jun-2022

BOQ

Name of Work:RE E TENDER FOR PROCUREMENT OF SOME ITEMS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC)
Sl. No. Item Description
1DIATHERMY, Short wave Diathermy Unit (Continuous and Pulsed )Technical Specification: Output of 400 to 500w in continuous mode and 800 to 1100 w in pulse mode pulse repetition frequency of 20 to 200 Hz adjustable in 10 steps LCD Screen display of parameter Treatment timer with all standard accessories condenser pad with cable Dis electrodes with arms and cables. Patient safety switch.
2VDRL Shaker Table/Bench top Centrifuge for VDRL Shaker with 16 socket : 1. Capacity 16X15ml. 2. Built in time and speed regulator with suitable speed indication and lid lock system. 3. RPM 5000 to 6000 rpm. 4. Power supply 220/240 volts, single phase, 50 cycles plus minus 12 AC. 5. A line voltage corrector of suitable rating should form part of the configuration as per IS. 9615/89. 6. Technical literature the firm shall submit printed illustrated technical literature/leaflet indicating the model number. If quoted model is a modified version of their any standard product that also be indicated in the offer.
3VDRL Shaker. 1. Feature for rotating slides for VDRL tests. 2. Specification Platform size 300X300 mm spring holder which can accommodate concave slides etc. 3. Rotation 180 rpm continuously adjustable with regulation. 4. Timer 0 to 30 minutes for control of shaking duration with 1 minute interval. 5. Power Supply 220 - 240 volts, 50 cycles, single phase with complete chord and plug. 6. Technical Literature the firm shall positively submit printed, illustrated technical literature/leaflet indicating the model quoted by them. If quoted model is a modified version of their any standard product that also be indicated in the offer.
4ULTRASOUND THERAPY UNIT (TWO HEADS)Technical Specification : Frequency of 1 & 3 MHz Intensity of 0-3 w/Cm2 with display of output parameters along with timer and two water proof treatment heads, one large to 5 cm second small up to 1.0 cmSystem configuration Accessories spares and consumables : - All standard accessories desired for proper functioning of the machine jelly as per requirement.
5VENTILATOR( Specification as per NIT Page number 29-34)
6ANESTHESIA MACHINE WITH VAPORIZERRobust structure construction with custom aluminum extrusions• & formed stainless steel work surfaceLarge anti-static caster wheels•Machine should be 3 gas delivery (O2, N2O• & Air) systems with pipeline connections and reserve cylinder yokesProvision to mount two O2• & one N2O pin indexed cylinder with gaugesColor coded ring indexed pipeline fittings and pressure gauges for each gas•5 Tube (antistatic coated) cascading flow meter assembly with back lighting•Lever operated or equally effective Anti hypoxic device to ensure minimum 21% Oxygen flow•Pneumatic operated Oxygen failure alarm•Interlocking mounting for two vaporizers•Pneumatic Audio• & Visual alarm for Oxygen failure when the pressure of the gas supply in the system fails below the required valueProvision to cut off Nitrous Oxide in case of Oxygen failure•Main switch for switching on the system•3 Liter Oxygen reservoir in build the main unit•Non return valve fitted to back bar to protect vaporizers from back pressure• 2Provision of Patient Air way pressure gauge•Three numbers of storage Drawer unit•Pin indexed yokes for mounting 2 – Oxygen and 1- Nitrous oxide Cylinders. Gauges to be• provided on the front panel with color-coding for Cylinder & Pipe line pressure.Auxiliary O2 outlet with flow meter.•Overhead monitor shelf.•Common gas outlet with emergency oxygen flush button and 50 cm / H2O blow off valve•O2 analysis (paramagnetic)• Should be supplied with: Adult & pediatric Brain circuit, Circle circuit (Disposable), pipeline houses for O2, N2O & Air. Vaporizer- Isoflourane & Servoflourane .

AI Tender Summary

OUR REF NO 32282532
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 15-06-2022
Authority
Authority Name Health And Family Welfare Department
Work Description Wbhf / Cms / Hst / 1P-114-2022 / Si-Rt ( 178 ) / 2022 / 198 / Group-Iii Re E Tender For Procurement Of Some Items For Two Years From The Date Of Award Of Contract ( Aoc ) , Diathermy, Short Wave Diathermy Unit ( Continuous And Pulsed ) Technical Specification: Output Of 400 To 500W In Continuous Mode And 800 To 1100 W In Pulse Mode Pulse Repetition Frequency Of 20 To 200 Hz Adjustable In 10 Steps Lcd Screen Display Of Parameter Treatment Timer With All Standard Accessories Condenser Pad With Cable Dis Electrodes With Arms And Cables. Patient Safety Switch. , Vdrl Shaker Table / Bench Top Centrifuge For Vdrl Shaker With 16 Socket : 1. Capacity 16X15ml. 2. Built In Time And Speed Regulator With Suitable Speed Indication And Lid Lock System. 3. Rpm 5000 To 6000 Rpm. 4. Power Supply 220 / 240 Volts, Single Phase, 50 Cycles Plus Minus 12 Ac. 5. A Line Voltage Corrector Of Suitable Rating Should Form Part Of The Configuration As Per Is. 9615 / 89. 6. Technical Literature The Firm Shall Submit Printed Illustrated Technical Literature / Leaflet Indicating The Model Number. If Quoted Model Is A Modified Version Of Their Any Standard Product That Also Be Indicated In The Offer. , Vdrl Shaker. 1. Feature For Rotating Slides For Vdrl Tests. 2. Specification Platform Size 300X300 Mm Spring Holder Which Can Accommodate Concave Slides Etc. 3. Rotation 180 Rpm Continuously Adjustable With Regulation. 4. Timer 0 To 30 Minutes For Control Of Shaking Duration With 1 Minute Interval. 5. Power Supply 220 - 240 Volts, 50 Cycles, Single Phase With Complete Chord And Plug. 6. Technical Literature The Firm Shall Positively Submit Printed, Illustrated Technical Literature / Leaflet Indicating The Model Quoted By Them. If Quoted Model Is A Modified Version Of Their Any Standard Product That Also Be Indicated In The Offer. , Ultrasound Therapy Unit ( Two Heads ) Technical Specification : Frequency Of 1 & 3 Mhz Intensity Of 0-3 W / Cm2 With Display Of Output Parameters Along With Timer And Two Water Proof Treatment Heads, One Large To 5 Cm Second Small Up To 1.0 Cm System Configuration Accessories Spares And Consumables : - All Standard Accessories Desired For Proper Functioning Of The Machine Jelly As Per Requirement. , Ventilator ( Specification As Per Nit Page Number 29-34 ) , Anesthesia Machine With Vaporizerrobust Structure Construction With Custom Aluminum Extrusions• & Formed Stainless Steel Work Surfacelarge Anti-Static Caster Wheels•Machine Should Be 3 Gas Delivery ( O2, N2o• & Air ) Systems With Pipeline Connections And Reserve Cylinder Yokesprovision To Mount Two O2• & One N2o Pin Indexed Cylinder With Gaugescolor Coded Ring Indexed Pipeline Fittings And Pressure Gauges For Each Gas•5 Tube ( Antistatic Coated ) Cascading Flow Meter Assembly With Back Lighting•Lever Operated Or Equally Effective Anti Hypoxic Device To Ensure Minimum 21% Oxygen Flow•Pneumatic Operated Oxygen Failure Alarm•Interlocking Mounting For Two Vaporizers•Pneumatic Audio• & Visual Alarm For Oxygen Failure When The Pressure Of The Gas Supply In The System Fails Below The Required Valueprovision To Cut Off Nitrous Oxide In Case Of Oxygen Failure•Main Switch For Switching On The System•3 Liter Oxygen Reservoir In Build The Main Unit•Non Return Valve Fitted To Back Bar To Protect Vaporizers From Back Pressure• 2Provision Of Patient Air Way Pressure Gauge•Three Numbers Of Storage Drawer Unit•Pin Indexed Yokes For Mounting 2 – Oxygen And 1- Nitrous Oxide Cylinders. Gauges To Be• Provided On The Front Panel With Color-Coding For Cylinder & Pipe Line Pressure.Auxiliary O2 Outlet With Flow Meter.•Overhead Monitor Shelf.•Common Gas Outlet With Emergency Oxygen Flush Button And 50 Cm / H2o Blow Off Valve•O2 Analysis ( Paramagnetic ) • Should Be Supplied With: Adult & Pediatric Brain Circuit, Circle Circuit ( Disposable ) , Pipeline Houses For O2, N2o & Air. Vaporizer- Isoflourane & Servoflourane .
Basic Detail
Tender No WBHF/CMS/HST/1P-114-2022/ SI-RT(178)/2022/198
Bidding Type Tender
Location
City kolkata
State West Bengal
Key Dates
Publish Date 03 Jun 2022
Submission Date 15 Jun 2022
Open Date 09 Jun 2022
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 1 Lakhs
Exemption Not Available
Document List
69ce7c8a-77c6-4122-97cb-61c52ed29c5e.html
BOQ_743897.xls
Technical_Data_Sheet_198.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 03, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 15, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 15, 2022
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 15, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 09, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

69ce7c8a-77c6-4122-97cb-61c52ed29c5e.html

xls

BOQ_743897.xls

xls

Technical_Data_Sheet_198.xls

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders