}

Wbhf / Cms / Hst / 1P-114-2022 / Si-Rt ( 178 ) / 2022 / 198 / Group-Iii Re E Tender For Procurement Of Some Items For Two Years From The Date Of Award Of Contract ( Aoc ) , Diathermy, Short Wave Diathermy Unit ( Continuous And Pulsed ) Technical , kolkata-West Bengal

Health And Family Welfare Department has published Wbhf / Cms / Hst / 1P-114-2022 / Si-Rt ( 178 ) / 2022 / 198 / Group-Iii Re E Tender For Procurement Of Some Items For Two Years From The Date Of Award Of Contract ( Aoc ) , Diathermy, Short Wave Diathermy Unit ( Continuous And Pulsed ) Technical . Submission Date for this Tender is 15-06-2022. Tanks and Cylinders Tenders in kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

32282532
Corrigendum : Wbhf / Cms / Hst / 1P-114-2022 / Si-Rt ( 178 ) / 2022 / 198 / Group-Iii Re E Tender For Procurement Of Some Items For Two Years From The Date Of Award Of Contract ( Aoc ) , Diathermy, Short Wave Diathermy Unit ( Continuous And Pulsed ) Technical
Open Tender
Indian
West Bengal
kolkata
15-06-2022

Tender Details

Wbhf / Cms / Hst / 1P-114-2022 / Si-Rt ( 178 ) / 2022 / 198 / Group-Iii Re E Tender For Procurement Of Some Items For Two Years From The Date Of Award Of Contract ( Aoc ) , Diathermy, Short Wave Diathermy Unit ( Continuous And Pulsed ) Technical Specification: Output Of 400 To 500W In Continuous Mode And 800 To 1100 W In Pulse Mode Pulse Repetition Frequency Of 20 To 200 Hz Adjustable In 10 Steps Lcd Screen Display Of Parameter Treatment Timer With All Standard Accessories Condenser Pad With Cable Dis Electrodes With Arms And Cables. Patient Safety Switch. , Vdrl Shaker Table / Bench Top Centrifuge For Vdrl Shaker With 16 Socket : 1. Capacity 16X15ml. 2. Built In Time And Speed Regulator With Suitable Speed Indication And Lid Lock System. 3. Rpm 5000 To 6000 Rpm. 4. Power Supply 220 / 240 Volts, Single Phase, 50 Cycles Plus Minus 12 Ac. 5. A Line Voltage Corrector Of Suitable Rating Should Form Part Of The Configuration As Per Is. 9615 / 89. 6. Technical Literature The Firm Shall Submit Printed Illustrated Technical Literature / Leaflet Indicating The Model Number. If Quoted Model Is A Modified Version Of Their Any Standard Product That Also Be Indicated In The Offer. , Vdrl Shaker. 1. Feature For Rotating Slides For Vdrl Tests. 2. Specification Platform Size 300X300 Mm Spring Holder Which Can Accommodate Concave Slides Etc. 3. Rotation 180 Rpm Continuously Adjustable With Regulation. 4. Timer 0 To 30 Minutes For Control Of Shaking Duration With 1 Minute Interval. 5. Power Supply 220 - 240 Volts, 50 Cycles, Single Phase With Complete Chord And Plug. 6. Technical Literature The Firm Shall Positively Submit Printed, Illustrated Technical Literature / Leaflet Indicating The Model Quoted By Them. If Quoted Model Is A Modified Version Of Their Any Standard Product That Also Be Indicated In The Offer. , Ultrasound Therapy Unit ( Two Heads ) Technical Specification : Frequency Of 1 & 3 Mhz Intensity Of 0-3 W / Cm2 With Display Of Output Parameters Along With Timer And Two Water Proof Treatment Heads, One Large To 5 Cm Second Small Up To 1.0 Cm System Configuration Accessories Spares And Consumables : - All Standard Accessories Desired For Proper Functioning Of The Machine Jelly As Per Requirement. , Ventilator ( Specification As Per Nit Page Number 29-34 ) , Anesthesia Machine With Vaporizerrobust Structure Construction With Custom Aluminum Extrusions• & Formed Stainless Steel Work Surfacelarge Anti-Static Caster Wheels•Machine Should Be 3 Gas Delivery ( O2, N2o• & Air ) Systems With Pipeline Connections And Reserve Cylinder Yokesprovision To Mount Two O2• & One N2o Pin Indexed Cylinder With Gaugescolor Coded Ring Indexed Pipeline Fittings And Pressure Gauges For Each Gas•5 Tube ( Antistatic Coated ) Cascading Flow Meter Assembly With Back Lighting•Lever Operated Or Equally Effective Anti Hypoxic Device To Ensure Minimum 21% Oxygen Flow•Pneumatic Operated Oxygen Failure Alarm•Interlocking Mounting For Two Vaporizers•Pneumatic Audio• & Visual Alarm For Oxygen Failure When The Pressure Of The Gas Supply In The System Fails Below The Required Valueprovision To Cut Off Nitrous Oxide In Case Of Oxygen Failure•Main Switch For Switching On The System•3 Liter Oxygen Reservoir In Build The Main Unit•Non Return Valve Fitted To Back Bar To Protect Vaporizers From Back Pressure• 2Provision Of Patient Air Way Pressure Gauge•Three Numbers Of Storage Drawer Unit•Pin Indexed Yokes For Mounting 2 – Oxygen And 1- Nitrous Oxide Cylinders. Gauges To Be• Provided On The Front Panel With Color-Coding For Cylinder & Pipe Line Pressure.Auxiliary O2 Outlet With Flow Meter.•Overhead Monitor Shelf.•Common Gas Outlet With Emergency Oxygen Flush Button And 50 Cm / H2o Blow Off Valve•O2 Analysis ( Paramagnetic ) • Should Be Supplied With: Adult & Pediatric Brain Circuit, Circle Circuit ( Disposable ) , Pipeline Houses For O2, N2o & Air. Vaporizer- Isoflourane & Servoflourane .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-May-2022 CORRIGENDUM-1 Date 15-06-2022
2 03-Jun-2022 CORRIGENDUM-2 Other 15-06-2022

Key Value

Document Fees
Refer document
EMD
INR 100000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail