Housing Urban and Rular Development Government Departments Closing in 0 days TDR #32280938

Balance Renovation And Misc. Works Of Main Academic, Administrative And Printing Blocks Ic Class Rooms And Laboratories, Co Security Guards Rooms And Toilet Water Proofing Treatment Of Existing Building Roofs Of Pit, Dseu Campus, Pusa, New Delhi.

Issued by Government Departments · safdarjung, Delhi
Tender Value
4.36 Crore
Estimated cost
Bid Submission
26 May 2022
0 days left
EMD
8.72 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
safdarjung → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Balance Renovation And Misc. Works Of Main Academic, Administrative And Printing Blocks Ic Class Rooms And Laboratories, Co Security Guards Rooms And Toilet Water Proofing Treatment Of Existing Building Roofs Of Pit, Dseu Campus, Pusa, New Delhi.

BOQ

Name of Work: -Balance Renovation and Misc. works of Main Academic, Administrative and Printing Blocks i/c Class Rooms &Laboratories, C/o Security Guards rooms and Toilet Water Proofing Treatment of existing building roofs of PIT, DSEU Campus, Pusa, New Delhi.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
2Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soilPipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
4Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
5Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20 mm nominal size)
61:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
7Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
8Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
9Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
10Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform
11Lintels, beams, plinth beams, girders, bressumers and cantilevers.
12Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo-Mechanically Treated bars of grade Fe-500 D or more.
13Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars
14Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
15Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
16Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V levelCement mortar 1:4 (1 cement :4 coarse sand) For partition wall
17Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab over 0.50 sqm.
18Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
19Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I), core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters and factory lamminated with 1.00 mm thickboth side decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.:37 (35+2=37) mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
20Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete.
21Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300x16 mm
22Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :200x10 mm
23Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :125 mm
24Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade with necessary screws etc. complete.Single rubber stopper
25Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
26Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes.
27Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
29Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15 x 3mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides.
30Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick.
31Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
32Providing and fixing digital ceramic glazed wall tiles size 300x450 mm conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
33Providing and laying rectified Glazed Ceramic floor tiles of size 400x400mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
34Providing and laying double charges vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1000x1000 mm
35Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling/grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 1000x1000 mm
36Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i)Single socketed pipes.110 mm diameter
37Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion.Bend 87.5°110 mm bend
38Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
39Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm ( + 0.05 %), total coated thickness with zinc coating 120 gm per sqm as per IS:277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
40Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 gm per sqm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Gutter .(600 mm over all girth).
4112 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
42Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm.
43Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work.
44Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work.
45Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
46Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge.With cement mortar 1:4 (1cement: 4 coarse sand).
47Demolishing mud phaska in terracing and disposal of material within 50 metres lead. .
48Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
49Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
50Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
51Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer\"s specifications & direction of Engineer in-Charge.60mm thick Cement concrete paver block of M-35 grade with approved colour, design & pattern
52Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever requiredWhite Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
53Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
54Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
55Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern
56Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap.
57Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
58Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm
59Providing and fixing soil, waste and vent pipes :100 mm dia.Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989.
60Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :For 100 mm dia. Pipe
61Providing and fixing plain bend of required degree.100 mm diaSand cast iron S&S as per IS - 3989
62Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100x100x100 mmSand cast iron S&S as per IS - 3989
63Providing and fixing single equal plain junction of required degree :100x100x100 mmSand cast iron S&S as per IS - 3989
64Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter:100 mm
65Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 100 mm outletSand cast iron S&S as per IS: 3989.
66Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal Work - Exposed on Wall. 20 mm nominal outer dia Pipes
67Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia .Pipes.
68Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore
69Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20 mm nominal bore
70Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
71Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Circular tank
72Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931:15 mm nominal bore.
73Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore.
74Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
75Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore.
76Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore15mm nominal bore
77Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
78Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length
79Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :150 mm diameter
80Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:150 mm diameter S.W. pipe
81Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
82Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete250 mm dia. R.C.C. pipe
83Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
84Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved qualityL D - 2.5Rectangular shape 600x450 mm internal dimensions
85Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
86For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
87Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination on both sides.
88Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness
89Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors ,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness.
90Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in-chargePowder coated minimum thickness 50 micron aluminium
91Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
92Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately).
93Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with waterproofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabsc) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.d)Finishing the surface with 20 mm thick joint less cement mortar of mix1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120mm and minimum thickness at khurra as 65 mm.
94Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
95Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
96Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part-4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm.Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall SS screws. The work shall be carried out as per specifications, drawing and as per directions of Engineer-in-Charge.With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles.
97Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge75mm average thickness
9850mm average thickness
99Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust freesteel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. Bars upto 12 mm diameter
100Bars above 12 mm diameter
101Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
102Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make
103Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/ mm2).50 mm average thickness in 3 layers.
104Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge. Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument. 75mm thick in Grade M 25 with cement content not less than 330 kg per cum
105Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of \"L\" shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by engineer-in-charge.
106Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mmi and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge Note: For WPC solid door/window frames, minus Smm tolerance in dimensions i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 45 x 70 mm
107Frame size 45 x 85 mm
108Providing andfixingfactory madesingleextrudedWPC(Wood PolymerComposite)soliddecorativetypeflushdoorshutterof required size comprising o/ virgin polymer of K value 58-60 (SuspensionGrade),calciumcarbonateand naturalfibers(wood powder/rice husk/wheathusk) and non toxic additives(maximum toxicityindexof12for100gms)havingminimumdensityof650 kg/cumandscrewwithdrawalstrengthof 1800 N(Face)& 900N (Edge),minimumcompressivestrength50N/mm2,modulusof elasticity850 N/mm2 and resistanceto spread offlame of Class A categorywith propertyof being termite/borerproof, water/moistureproofandfireretardant.WPCtobelaminated withPVCfoilofminimum14micronsthickofapproveddesign pastedwith hot melt adhesiveon bothfaces of shutterand fixing with stainlesssteel butt hinges of required size with necessaryfull bodythreadedstarheadedcountersunkS.Sscrews,allasper directionof Engineer-In-Charge.(Note: stainlesssteel butt hinges and necessary S.S screws shall be paid separately) 30m mm thick
109Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white colour and other side of board laminated with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm*, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.18 mm thick
110Dismantling wall tiles including dismantling plaster and raking out joints complete and preparing the surface for new plaster as per direction of Engineer-in-Charge. The cost inclusive of disposal of unserviceable material at suitable place outside the building campus as suggested by the client.
111Dismantling old Trafelt/ APP sheet and cleaning the roof surface including collecting malba and carrying level for disposal from top floor to ground floor within 50 metrer lead oras per direction of Engineer-in-Charge
112Providing and applying 12 mm thick(average) premixed formulated ready mix polymer ,modified cement plaster such as \"Ready Plast\",\"Silco Plast\",Perma plast mix\",Insta-plast\" or equavalent having polymer & fibre additives in required proportion produced at automated dry mix plant,applied on hacked/uneven/plain back ground such as RCC/AAC blocks/brickwork on external walls for all height from ground level,finished in smooth lineand level etc.,complete .the ready mix plaster should confirm to following properties:-(A) Adhesion of concrete(after 28 days)>1.0 N/mm2(B)compressive strength (after 28 days)> 13.0 N/mm2 (C) Split tensile strength (after 28 days0> 2.50N/mm2 (D)Dryinh shrinkage 9after 35 days)< 0.022%. The average consumption should not be less than 30.50 kg/sqm and work should be done as per directions of Engineer-in-Charge&Specification by manufacturer.
113Providing and applying 15 mm thick(average) premixed formulated ready mix polymer ,modified cement plaster such as \"Ready Plast\",\"Silco Plast\",Perma plast mix\",Insta-plast\" or equavalent having polymer & fibre additives in required proportion produced at automated dry mix plant,applied on hacked/uneven/plain back ground such as RCC/AAC blocks/brickwork on external walls for all height from ground level,finished in smooth lineand level etc.,complete .the ready mix plaster should confirm to following properties:-(A) Adhesion of concrete(after 28 days)>1.0 N/mm2(B)compressive strength (after 28 days)> 13.0 N/mm2 (C) Split tensile strength (after 28 days0> 2.50N/mm2 (D)Dryinh shrinkage 9after 35 days)< 0.022%. The average consumption should not be less than 30.50 kg/sqm and work should be done as per directions of Engineer-in-Charge&Specification by manufacturer.
114Providing and fixing 18mm thick gang saw cut mirror polished for wall lining (vaneer work) including dado, skirting, risers of steps etc. in required design and pattern wherever required stone on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.30 kg / sqm including pointing with white cement slurry admixture with pigment of matching shade including rubbing curring, polishing etc. all complete as per direction of Engineer-in-Charge. (a) 18mm thick granite of any colour and shade.
115Providing and placing highstrength, non shrink pre-packed free flow micro concrete having compressive strength of 35 NPa at 28 days (compressive strength of one day should not less than 15 NPa} as per specifications. The micro concrete mix shall be prepared by mixing non shrink prepacked free flow micro concrete powder with well graded cleaned crushed, aggregate 6 mm & down in proponion of 1: 0.32 1 part prepack micro concrete powder : 0.32 pan stone aggregale) by weight for repairing excessively damaged area of structural elements excluding reinforcement but including scaPolding, centering, fixing watenig ht for work, shuttering, curing inclusive of all labour, materials, equipment etc. complete as per specifications and instructions of Engineer-in- charge. This item includes submission of design mix for compresive strength of 3 S NPa at 28 days from any Government approved laboratoary / innitution for approval of Engineer-in charge. The charges for the shift shall be borne by agency. Note: - I\Ion shrink prepacked micro concrete powder content considered in this item is 1648 kg / cum. Excess / less micro concrete powder used as perdesign mixis payable / recoverable se aratel.
116Providing and fixing 15 mm dia C.P. BrassSwan neck pillar cock of approved quality complete as per direction of Engineer-in-charge
117Providing and fixing in position wall paneling of approved make as per direction of engineer-in-charge grooved wood panels esto of width 192mm, thickness of 16mm and length 2440 mm made up of high density fibre board with minimum density of 800 Kg/m3 substrate with a laminated facing as per the approved shade/species & finish with melamine balancing layer on the reverse side. The boards shall have a special perforation pattern of 3 mm grooves at 21mm pitch. The panels shall have fire resistance of Class I, BS 476 part 7. The edges of the panels shall be “tongued-and-grooved” to receive special clips for installation. The back of the perforated panels shall have sound absorbing non-woven acoustical fleece and backed with 50 mm thick rock wool layer as directed by the Engineer-in-Charge. The panels shall be mounted on special channels using clips as approved by the Engineer -in-charge. Install G.I stud of section 48X34X36 mm or as approved by the Engineer -in- Charge on the solid wall using screws at spacing of 600mm centre-to-centre. Screw the aluminium channel (keel) on channelled G.I stud 600mm centre to centre. Install the first set of wooden panels by inserting the clips. For border channel insert the groove of the panel in to the projecting flange of the clip. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing clips for inside channel into the next aluminium channel (keel) and simultaneously fill the gap between wall & panel with 50 mm thick rock wool having density of 48 kg/m3. Continue the process till the actual height is achieved. Use clips for border channel to finish off the installation, finish the edges and joints using wood moulding of matching colour (to be provided by others) as approved by Engineer-in- Charge. The installed panels should give an NRC of 0.9.:
118Providing and fixing oval shaped wash basin of approved make such as Cera, Hindware, Perryware or equivalent with 15 mm CP brass swan pillar cock, kington/GEM/Techno/Parko, 32 mm CP brass wate of standard pattern, i/c cutting and making good the walls wherever required : coloured vitreous china : Oval shaped wash basin size 550x450 mm with with a single 15 mm CP brass swan pillar cock.
119Providing and fixing 1mm thick M.S./G.I.Deck profile sheet (Size, shape and pitch of corrugation as approved by Engineer-in-charge) on existing steel frame all complete as per direction of Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
120Credit for taking away ofwooden windows/Doors,partition & wooden wall liningetc. and the like received from the dismantling window/ventilators. The material so received shall be properly of the contractor after dismantling duely weighted/measured before removing from the site in the presence of Engineer-in-Charge or his authorised representative all complete.
121Credit for takingawayof Window/Ventilators MSgrilletc.Roundor squaresteel bars , flatetc. andthe likereceivedfromthedismantlingwindow/ventilators. Thematerial shallbe properlyofthecontractorafterdimantlingduely weighted /Measuredbeforeremovingfromthe sitein the presence of engineer-in-charge
122Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
123Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C
124Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1252 X 4 sq. mm + 1 X 4 sq. mm earth wire
1262 X 6 sq. mm + 1 X 6 sq. mm earth wire
1274 X 4 sq. mm + 2 X 4 sq. mm earth wire
1284 X 6 sq. mm + 2 X 6 sq. mm earth wire
129Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
1306 x 1.5 sq. mm
1313 x 4 sq. mm
1323 x 6 sq. mm
133Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm
13425 mm
13532 mm
136Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100 mmX75 mm)
1376 Module (200 mmX75 mm)
1388 Module (125 mmX125 mm)
13912 Module (200 mmX150 mm)
140Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
14115/16 A switch
1426 pin 15/16 A socket outlet
143Supplying, installation, testing &Commissioning of surface/wall mounted 38W to 40W integrated LED 4 feet fitting with epoxy powder coated white/grey extruded aluminium channel housing for efficient heat issipation. Total system Lumen of 38W to 40W Led should be 3600 or above in cool daylight (5700K to 6500K), power factor>0.95, CRI>80, complete with mounting brackets & accessories as required with connections.
144Supplying, installation, testing & Commissioning of surface/recess type 34W to 36W Full window glarefree opal Diffuser LED Panel of size 600X600mm suitable for Armstrong/POP/GB ceiling with MS Powder coated White Housing. Total system Lumen of 34W to 36W LED should be 3400 or above in Cool day Light(5600K to 6500K), Power factor>0.95, CRI (Ra) >80, LED Lamp Efficacy>130 Lm/W. Complete with all accessories as required with connections etc. complete as reqd.
145SITC of 15-18 watt surface mounted Square Down lighter LED fittings size 1 ft x 1 ft. having minimum system efficacy of 100 lumens/watt and colour temperature of 5500-6500 kelvin and CRI of >80 and having power factor of >0.95, THD <10% i/c fixing on the surface with the help of suitable size of screw and fastners i/c connections with 3x1.5 Sq mm FRLS PVC Insulated copper conductor cable etc. complete as reqd.
146Supplying Installation, testing and commissioning of 1200 mm sweep ceiling fan with copper binding including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, complete etc. as required.
147SITCof 1400mm nominal size ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
148Supplying ,installation& testing & commissioning of 400 mm Wall Fan Oscillating type with speed regulator with string, Aerodynamically designed & balanced blades complete with all accessories i/c connection, testing, commissioning etc. as required.
149Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
150Supplying & Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade aluminium armoured cable of following size on wall surface as required. 3 x 10 sqmm
1513.5 x 50 sqmm
1524 x 16 sqmm
1534 x 25 sqmm
154Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3 X 10 sq. mm (22mm)
1553½ X 50 sq. mm (35 mm)
1564 X 16 sq. mm (28mm)
1574 X 25 sq. mm (28mm)
158Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
159Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 kA,TPMCCB
160Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
161Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
162Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
163Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door
164Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
165Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
166Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
167Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
168Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
169Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
170Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
171Fabrication, supplying and fixing of indoor cubical type panel board, dust, damp and vermin proof, compartmentalized, free floor standing, made out of 2.0 mm thick CRCA sheet minimum 30 cm deep (NS) duly powder coated & painted (CPRI approved) complete with 4 strips alu. bus bar of 1.5 time of incomer capacity complete with solid connection, interconnections, internal wiring with copper conductor cable of suitable sizes, earthing i/c testing & commissioning etc. as reqd. (Main panel)
172Providing & Fixing of following electrical accessorries/switches etc in the above existing panel board including testing, commissioning etc. as reqd. 250 A, 25 KATPMCCB
173125 A, 16 KATPMCCB
17463 A, DP MCB
17540 A, DP MCB
176Digital Volt Meter (0-500) V 96 sq. mm with selector switch
177Digital Ammeter (0-250) with selector switch
178CT (250/5)
179Indicator Lamp
180Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
181Supplying & Fixing modular type Internet Socket outlet existing modular plate & switch box i/c connection etc excluding modular plate etc as reqd.
182Supplying & fixing of electronic Ding Dong Door bell suitable for single phase 230V i/c connections with 1.5 sqmm copper conductor cable, testing & commissioning etc complete as reqd.
183Supplying & fixing remote bell having range upto 100 mm (open area)1.36 selectable tunes, tune selector & volume controller button, operating frequency 315mHz, compact size & long operating life etc complete as reqd.
184Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt) as required.
185Providing and fixing of the commercial PVC DLP trunking of following nominal size complete with end cover, flexible cover, separation partition bend (internal/ external) wherever required at the site etc. complete as reqd. (Make AKG) Size 100mm (W) x 50mm (D) (N.S.)
186Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
187Supply and Installation. Of premium quality electromechanical swing type Barrigate L-3 to 6 Meter Data 1. Opening and closing time - (3 Sec to 9 sec) noiceless with auto cooling system with reflecting LED lights and tapes in length, rated power, 100 w/40 Kg, 40 NM-50/60 Hz, CE-Certified, i/c of following details: a) PC Safety Anti Accident Device b) Loop Control c) 3 Way Opening Switch Controller d) 2 Way road light 8\" Dia e) 1 Grade concrete cement work in platform construction
188Supply, Installation. Testing & commissioning ofinverter type Split AC unit of 2 TR capacity and having minimum cooling capacity not less then 7000 watts complete with Indoor unit & condensing unit, filtering, dehumidifying etc suitable for operation on 230 volts AC supply single phase 5 star and drain connector pipe complete with minor repairing of civil work at site complete etc as required.
189Providing & fixing of MS powder coated outdoor wall mounting Stand suitable for 1.5/2.0 TR capcity spilit AC outdoor unit complete etc as reqd.
190Supplying and fixing of 4 KVA voltage stabilizer with TDR suitable for input 145-280 V & output 195-245V, three step with high voltage Trip & MCB on surface complete with connections testing & commissioning etc. as reqd.
191Supply, Installation, testing and commissioningfollowing nominal sizes of soft/hard drawn copper refrigerant piping for 2.0/1.5 TR Split AC Suction & Discharge , complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required
192Providing & laying of 3 x 2.5 sqmm copper flexible FRLS PVC insulated PVC sheathed copper conductor cable unarmoured for split AC making connection complete etc as reqd.
193Supplying & fixing of 15 Amp Plug Top for main supply of AC making connection complete etc as reqd.
194Supplying & fixing of 25mm dia PVC heavy duty pipe drainage in the existing split type AC unit with supporting clamps etc complete as reqd.
195Credit for old dismantle material as and where basis etc as reqd. Old Assorted Tube fitting 40 w
196Old Assorted 1200/1400 mm Ceiling Fan
197Old Assorted Copper wire
198Old Assorted SP/DP/TP MCB
199Old Assorted 5/16 Amp Switch/Socket
200Old Assorted DB
201Add CPWD Cost [email protected]%(On Civil work)
202Deduct PWD Cost [email protected]%(On Civil work)

AI Tender Summary

OUR REF NO 32280938
AUTHORITY Government Departments
TENDER VALUE 4.36 Crore
LAST DATE 26-05-2022
Authority
Authority Name Public Works Department
Work Description Balance Renovation And Misc. Works Of Main Academic, Administrative And Printing Blocks Ic Class Rooms And Laboratories, Co Security Guards Rooms And Toilet Water Proofing Treatment Of Existing Building Roofs Of Pit, Dseu Campus, Pusa, New Delhi.
Basic Detail
Tender No 19/EE/CBMD M-121(N)/2022-23
Bidding Type Tender
Location
City safdarjung
State Delhi
Key Dates
Publish Date 18 May 2022
Submission Date 26 May 2022
Open Date 26 May 2022
Finance
Tender Value 4.36 Crore
Tender Fee Ref. Documents
EMD 8.72 Lakhs
Exemption Not Available
Document List
7336f245-1c8f-4de9-83f8-4d31efa6224b.html
BOQ_287179.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 18, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
May 26, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 26, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

7336f245-1c8f-4de9-83f8-4d31efa6224b.html

xls

BOQ_287179.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender