}

Fixing Of Rates For Hitech Semihitech Green Houses And Related Structures Works , Manufacturing, Providing And Installation Of “Hi –Techgreen House-Cum- Mist Chamber Structure Soft Soil With Buffer Room ”-Successful Commissioning Thereof. Technical , bemina-Jammu And Kashmir

Jammu And Kashmir Small Scale Industries Development Corporation Limited has published Fixing Of Rates For Hitech Semihitech Green Houses And Related Structures Works , Manufacturing, Providing And Installation Of “Hi –Techgreen House-Cum- Mist Chamber Structure Soft Soil With Buffer Room ”-Successful Commissioning Thereof. Technical . Submission Date for this Tender is 09-06-2022. Coats and Jackets Tenders in bemina Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

32278378
Fixing Of Rates For Hitech Semihitech Green Houses And Related Structures Works , Manufacturing, Providing And Installation Of “Hi –Techgreen House-Cum- Mist Chamber Structure Soft Soil With Buffer Room ”-Successful Commissioning Thereof. Technical
Open Tender
Indian
Jammu And Kashmir
bemina
09-06-2022

Tender Details

Fixing Of Rates For Hitech Semihitech Green Houses And Related Structures Works , Manufacturing, Providing And Installation Of “Hi –Techgreen House-Cum- Mist Chamber Structure Soft Soil With Buffer Room ”-Successful Commissioning Thereof. Technical / Operational Parameters Structure Size ( Working Area ) : 20M X5mx4mx 2.5 M ( L X W X Ch: Sh ) Total Area100sqm. Buffer Room- 2M X 2M X 3M X2m ( L X W X Ch : Sh ) Provided With Air Curtain ( A ) .G.I. Structure 20 M X 5M With Buffer Room 2M X 2M: 1.Gi Pipe ( 50X50mm ) Specification: A / Gi Pipe Isi Standard: - Is 1239 B Class Construction Use. B / - Thickness: - 2Mm C / - Gi Coat Isi Standard: - Is 4736-1968 / Iso65-1973 D / - Weight 50Mm X50mm: - 20Kg / Length Of 20’. Gi ( 50X50mm ) Isi Standard Is 1239 Class B Anti-Corrosive, Humidity Resistant Pipe With Is 4736-1968 / Iso 65-1973 Zinc Coat As Approved For Maximum Indian Wind Load Conditions, Structural Trusses Be Provided For Absolute Strengthwind Load 160Km / Hr ( Bl3-P Rigid, Wind Resistant Frame. ) Reinforced Rigid Frame Walls And Ceiling Sealed With Internal Shell. A / -Trusses : -50Mm X 50Mm B / -Vertical Supports50mm X 50Mm C / -Purline50mm X 50Mm Trusses:- 11 Nos. ( 15 Meter Each ) , Vertical Supports:-23 Nos. ( 3 Meters Each ) , Centre Vertical Supports:-22 Nos. ( 2 Meters Each ) , Purlines ( Side Wise ) :-4Nos. ( 20 Meters Each ) , Purlin ( Roof Top ) :-5Nos. ( 20 Meters Each ) , Purlin Front / Back:-4 Nos. ( 5 Meter Each ) Buffer Room Trusses:- 2 Nos. ( 5 Meter Each ) , Vertical Supports:-8 Nos. ( 3 Meters Each ) , Purlines ( Side Wise ) :-6Nos. ( 2 Meters Each ) , Purlin ( Roof Top ) :-3Nos. ( 2 Meters Each ) , Purlin Front & Back:-2 No. ( 2 Meter Each ) :- 2-Aluminium Strips / Profile ( Side & Top ) 2” -Weight 0.35 Kg / Mtr Perforated Anti Dust :-300Mtr 3-Aluminium Angle 2”X2” ( Front& Back ) - Weight 0.35 Kg / Mtr Perforated Anti Dust :-100Mtr 4-Aluminium Door Of Size -2M X 1M Of Aluminum Section With Polycarbonate Sheet 6Mm Thick As Cladding Material With Proper Locking System And Hydraulic Door Closeralso Be Provided:- 02 Nos Job. 5-Aluminium Windows Of Size – 1Mtr X 0.5Mtr Of Aluminum Section With Polycarbonate Sheet 6Mm Thick 6 Nos 6-Poly Carbonate Sheet 8Mm; Specifications Multi Walled Impact Resistant, Energy Saving. Unbreakable, ( Impact Resistant Upon Thickness And Color Selection. Excellent Weather Resistance: 10 Yearswarranty ( Protection Against The Damaging Effects Of Uv Radiation In Sunlight ) Safe Fire Performance:Self-Extinguishing And Difficult To Ignite. Light Weight:Weight Ranging From 1.3 Kgs / Sqm For 6Mm. Sound Insulation As Per Din 52210 ( Db ) : 18 Db Dura Tuf Make :- 3080 Sq Feet. 7- Air Curtain: Size: 3’ Wide Heavy Duty, Cabinets Of Air Curtain Are Made Of Cold Rolled Mild Steel Sheets. The Blowers Are Made Of High Quality Alu. Sheets With ½ Hp Motor & Double Blower System, Powder Coated Finish At Pre Entry Point, Entry With Automatic Main On / Off Operation At The Time Of Door Opening / Closing:- 1 Nos. ( B ) Microprocessor Photosynthesis Monitor Panel: Heating, Cooling & Humidity Microclimatic Temperature Controller Specifications: Real Time Microprocessor Based Pid Controller , 4 Digit Led Display For Displaying Measured ( 14Mm, 8Mm ) / Displaying Settings, Soft Touch Operation , Platinum Sensor Probe Pt-100 Set Point Lock Within The Setting Panel To Protect Setting Changes, Level Lock To Ensure That The Parameter Can Be Read But Cannot Be Changed, Sensor Failure Indication, Display Resolution 0.1 % C, Automatic Hysteresis Control. Wide Selectable Temperature Ranges From 0%. Accuracy + 0.1 % C, 4.4 Kva Load Can Be Directly Connected To The Powered Output, Input – 200-240 Vac, 50 Hz. Single Phases. , Ambient 5 Degree -50 Degree C, Rh Up To 90%. Microclimatic Humidity Controller Specification: Microprocessor Based, On / Off Control For Humidifying / Dehum, Hysteresis / Differential 1% - 9%, Delay Timer 0-240 Sec, Direct / Reverse Selectable, Lock Functions To Prevent Miss Operating, Feather Touch Operation, Fast Response Sensor – Line Resistance < 100, Display Accuracy – Indicating Value + 0.2 % + 0.2 % + 1 Digit. Piltz / Cyclic Timer For Humidity: Specific For Fogging, Misting System, Controlled By Timer. To Reduce Water Logging Condition In The Transgenic Greenhouse Each. Specification: 0.999 Min / Sec On, 0-999 Min / Sec Off, Automatic Cycling Accuracy Quartz, Power Output Can Be Directly Drive Misting Unit Load Up To 4.4 Kva, Input 200 V To 240 Va.C, Phase- Single, 50 Hz, Ambient 4 Degree C To 50 Degree C, Rh U [ To 90%:- 1 Nos. ( C ) Evaporative Cooling System ( Ecs ) : 1.Pad Size: ( 16Ft X5ftx4” Thick ) With Cellulose Pads To Acquire Proper Cfm Of Air Movement Per Sq.Ft Of Area Will Be Provided.. Even Water Delivery Through Distribution Pipe Will Be Ensured. Technical Parameters Of Cellulose Pad: Paper Ambient Condition 25°- C -45 °- C Estimated Cooling Load: 101, 520 Btus / Hrs. Total Water Flow 7.56 Lpm Per Sq. Ft.Of The Top Pad Surface. Bleed Of Equal To 10% Of Total Water Rate. Eco Friendly.High Saturation Efficiency Self-Cleaning Feature No Setting Or Shrinkage Of Product Low Pressure Drop Characteristics. Impregnation Makes The Material Stiff And Self-Supporting Make: ( Standard ) Colling Pad Accessories:- Tray Material: - Tray Side, Top Etc. Over: - 20Mm Pvc Drain: - 32 Mm Standard Pvc. Construction Material: 20 Ga Gi / Ai Sheets: Tray Side, Top Etc. Cooling Media: 100 Mm Thick At Velocity Of 1 To 3 Micro Sleves To Give Efficiency From 60 To 95%. 2.Filtration : Screen Filter. 3.Miscellaneous: Fasteners, Galvanized, Rivet- Aluminum. 4.Pump : 1 Hp Monoblock ( Standard Make ) =1No 5.Co-Axial Flow Fan 48”:2 Nos 6.40 X40 Mesh ` : For Extra Protection From Deserts Sand / Dust Fitted ( D ) Heating System: - Providing Heavy Duty Forced Heat Convection System Which Is Ideal For Heating In Biotech Work And Green House. Automatic Thermal Cut Off Device, Biotech Grade 2.5Kw. It Has Isi Standard Make Heating Element And Isi Standard 900Rpm Speed Fan. Input 200-240 Vac, 50 Hz, Single Phase.No Of 1.Heaters-4Nos. ( E ) Lighting System:- Providing Of 8 Nos Of Flurecent Tubes High Luminous Of Standard Make. These Lamps Are Provided For Increasing Day Length With Specific Wave Length & Spectrum And Using In Green House Globally For Best Production In Floriculture / Horticulture / Forestry Etc Technical Specification Of Par Lamps: Lamp Wattage ( W ) 36 Luminous Flux1350 Luminous Efficacy ( Lm / U ) 19.3 Photosynthesis Watt ( W ) ( Photosynthetic Effects Of Lamp ) 5.58 Efficacy ( Mw / W ) ( Results Of Effectiveness ) Photosynthetic Radiation 79.7 Photosynthesi ( W / M2 ) Capability Of Photosynthetic Radiation Which Adjusted Light Lux4.13 Flurecent Tubes ( Effectiveness Of Light Beam Area ) 5.45 400-700Nm 25.5 350-500Nm 7.26 600-700Nm 13.2 1 / - Totalflurecent Tubes 22Watt: 8 Nos. 2 / - Normal Fluorescent Lights: 1 Nos. ( F ) Humidity System:Through Micro Humidification To Create The 60-80% Accuracy + 3-5% Humidity: - Installation Of High Pressure Foggers Does Not Drip During The Function. Working Pressure: -4 Bar At This Pressure, The Average Droplet Size: 50 To 100Mm. Density: - One Fogger To 0.3M-0.4Mfor Propagation. 1. Fogger: -Cross Way Nozzle, Hanging Type = 45 Nos. Fogger Discharge Range: -7.0 Lph. 2.Pipe: -16Mm Lldpe ( Class 2 ) 3.Motor: - 1 Hp Monoblock Pump ( Isi Make ) 1 No. 4.Filter ( Screen ) :-Isi Standard = 1 No. 5.Tank: - 1000 Ltr ( Isi Make ) 1No 6.Pvc / Astmd Pipe ( 32Mmx25mm ) 12Mtr ( G ) Shading System:- Providing Of Shade Net 50%:-120Sq Mtr. ( H ) Civil Work:- Cc Foundation ( 1:3:6 ) 1’ Feet Below And 2’ Above Ground Level To Check Lateral Moments Of Water, Base Pcc 2” Thick, 9” Wide Curtain Wall ( 3Feet Height ) Duly Plastered. Earth Work Excavation Of Size 1.25’ X 125’ X 1’ = 5 Cum , Stone Soling Hand Paced 5Cum& Concreting For Structure 55M X 1M X 0.3M, Alongwith Concrete Base For Water Tank 4’X4’X3”, Buffer Room Concrete Base 2M X2m = 1Nos = 18 Cum. ( I ) Electrification:- Mcb Box, Mcb, Wire, Conduit 1”, Service Line ( 15 Meter Of 16Mm, 2 Core Aluminium ) Of Standard Make :-01 Job , Manufacturing, Providing And Installation Of “Hi –Techgreen House-Cum- Mist Chamber Structure With Buffer Room, Hard Soil ( Concrete Floor ) .”-Successful Commissioning Thereof. Technical / Operational Parameters Structure Size ( Working Area ) : 20M X5mx4mx 2.5 M ( L X W X Ch: Sh ) Total Area100sqm. Buffer Room- 2M X 2M X 3M X2m ( L X W X Ch : Sh ) Provided With Air Curtain ( A ) .G.I. Structure 20 M X 5M With Buffer Room 2M X 2M: 1.Gi Pipe ( 50X50mm ) Specification: A / Gi Pipe Isi Standard: -Is 1239 B Class Construction Use. B / - Thickness: - 2Mm C / - Gi Coat Isi Standard: -Is 4736-1968 / Iso65-1973 D / - Weight 50Mm X50mm: -21Kg / Length Of 20’. Gi ( 50X50mm ) Isi Standard Is 1239 Class B Anti-Corrosive, Humidity Resistant Pipe With Is 4736-1968 / Iso 65-1973 Zinc Coat As Approved For Maximum Indian Wind Load Conditions, Structural Trusses Be Provided For Absolute Strengthwind Load 160Km / Hr ( Bl3-P Rigid, Wind Resistant Frame. ) Reinforced Rigid Frame Walls And Ceiling Sealed With Internal Shell. A / -Trusses : -50Mm X 50Mm B / -Vertical Supports50mm X 50Mm C / -Purline50mm X 50Mm Trusses:- 11 Nos. ( 15 Meter Each ) , Vertical Supports:-23 Nos. ( 3 Meters Each ) , Centre Vertical Supports:-22 Nos. ( 2 Meters Each ) , Purlines ( Side Wise ) :-4Nos. ( 20 Meters Each ) , Purlin ( Roof Top ) :-5Nos. ( 20 Meters Each ) , Purlin Front / Back:-4 Nos. ( 5 Meter Each ) Buffer Room Trusses:- 2 Nos. ( 5 Meter Each ) , Vertical Supports:-8 Nos. ( 3 Meters Each ) , Purlines ( Side Wise ) :-6Nos. ( 2 Meters Each ) , Purlin ( Roof Top ) :-3Nos. ( 2 Meters Each ) , Purlin Front & Back:-2 No. ( 2 Meter Each ) :- 2-Aluminium Strips / Profile ( Side & Top ) 2” -Weight 0.35 Kg / Mtr Perforated Anti Dust :-300Mtr 3-Aluminium Angle 2”X2” ( Front& Back ) - Weight 0.35 Kg / Mtr Perforated Anti Dust :-100Mtr 4-Aluminium Door Of Size -2M X 1M Of Aluminum Section With Polycarbonate Sheet 6Mm Thick As Cladding Material With Proper Locking System And Hydraulic Door Closeralso Be Provided:- 02 Nos Job. 5-Aluminium Windows Of Size – 1Mtr X 0.5Mtr Of Aluminum Section With Polycarbonate Sheet 6Mm Thick 6 Nos 6-Poly Carbonate Sheet 8Mm; Specifications Multi Walled Impact Resistant, Energy Saving. Unbreakable, ( Impact Resistant Upon Thickness And Color Selection. Excellent Weather Resistance: 10 Yearswarranty ( Protection Against The Damaging Effects Of Uv Radiation In Sunlight ) Safe Fire Performance:Self-Extinguishing And Difficult To Ignite. Light Weight:Weight Ranging From 1.3 Kgs / Sqm For 6Mm. Sound Insulation As Per Din 52210 ( Db ) : 18 Db Dura Tuf Make :- 3080 Sq Feet. 7- Air Curtain: Size: 3’ Wide Heavy Duty, Cabinets Of Air Curtain Are Made Of Cold Rolled Mild Steel Sheets. The Blowers Are Made Of High Quality Alu. Sheets With ½ Hp Motor & Double Blower System, Powder Coated Finish At Pre Entry Point, Entry With Automatic Main On / Off Operation At The Time Of Door Opening / Closing:- 1 Nos. ( B ) Microprocessor Photosynthesis Monitor Panel: Heating, Cooling & Humidity Microclimatic Temperature Controller Specifications: Real Time Microprocessor Based Pid Controller , 4 Digit Led Display For Displaying Measured ( 14Mm, 8Mm ) / Displaying Settings, Soft Touch Operation , Platinum Sensor Probe Pt-100 Set Point Lock Within The Setting Panel To Protect Setting Changes, Level Lock To Ensure That The Parameter Can Be Read But Cannot Be Changed, Sensor Failure Indication, Display Resolution 0.1 % C, Automatic Hysteresis Control. Wide Selectable Temperature Ranges From 0%. Accuracy + 0.1 % C, 4.4 Kva Load Can Be Directly Connected To The Powered Output, Input – 200-240 Vac, 50 Hz. Single Phases. , Ambient 5 Degree -50 Degree C, Rh Up To 90%. Microclimatic Humidity Controller Specification: Microprocessor Based, On / Off Control For Humidifying / Dehum, Hysteresis / Differential 1% - 9%, Delay Timer 0-240 Sec, Direct / Reverse Selectable, Lock Functions To Prevent Miss Operating, Feather Touch Operation, Fast Response Sensor – Line Resistance < 100, Display Accuracy – Indicating Value + 0.2 % + 0.2 % + 1 Digit. Piltz / Cyclic Timer For Humidity: Specific For Fogging, Misting System, Controlled By Timer. To Reduce Water Logging Condition In The Transgenic Greenhouse Each. Specification: 0.999 Min / Sec On, 0-999 Min / Sec Off, Automatic Cycling Accuracy Quartz, Power Output Can Be Directly Drive Misting Unit Load Up To 4.4 Kva, Input 200 V To 240 Va.C, Phase- Single, 50 Hz, Ambient 4 Degree C To 50 Degree C, Rh U [ To 90%:- 1 Nos. ( C ) Evaporative Cooling System ( Ecs ) : 1.Pad Size: 16Ft X5ftx4” Thick ) With Cellulose Pads To Acquire Proper Cfm Of Air Movement Per Sq.Ft Of Area Will Be Provided.. Even Water Delivery Through Distribution Pipe Will Be Ensured. Technical Parameters Of Cellulose Pad: Paper Ambient Condition 25°- C -45 °- C Estimated Cooling Load: 101, 520 Btus / Hrs. Total Water Flow 7.56 Lpm Per Sq. Ft.Of The Top Pad Surface. Bleed Of Equal To 10% Of Total Water Rate. Eco Friendly.High Saturation Efficiency Self-Cleaning Feature No Setting Or Shrinkage Of Product Low Pressure Drop Characteristics. Impregnation Makes The Material Stiff And Self-Supporting Make: ( Standard ) Colling Pad Accessories:- Tray Material: - Tray Side, Top Etc. Over: - 20Mm Pvc Drain: - 32 Mm Standard Pvc. Construction Material: 20 Ga Gi / Ai Sheets: Tray Side, Top Etc. Cooling Media: 100 Mm Thick At Velocity Of 1 To 3 Micro Sleves To Give Efficiency From 60 To 95%. 2.Filtration : Screen Filter. 3.Miscellaneous: Fasteners, Galvanized, Rivet- Aluminum. 4.Pump : 1 Hp Monoblock ( Standard Make ) =1No 5.Co-Axial Flow Fan 48”:2 Nos 6.40 X40 Mesh ` : For Extra Protection From Deserts Sand / Dust Fitted ( D ) Heating System: - Providing Heavy Duty Forced Heat Convection System Which Is Ideal For Heating In Biotech Work And Green House. Automatic Thermal Cut Off Device, Biotech Grade 2.5Kw. It Has Isi Standard Make Heating Element And Isi Standard 900Rpm Speed Fan. Input 200-240 Vac, 50 Hz, Single Phase.No Of 1.Heaters-4Nos. ( E ) Lighting System:- Providing Of 8 Nos Of Flurecent Tubes High Luminous Of Standard Make. These Lamps Are Provided For Increasing Day Length With Specific Wave Length & Spectrum And Using In Green House Globally For Best Production In Floriculture / Horticulture / Forestry Etc Technical Specification Of Par Lamps: Lamp Wattage ( W ) 36 Luminous Flux1350 Luminous Efficacy ( Lm / U ) 19.3 Photosynthesis Watt ( W ) ( Photosynthetic Effects Of Lamp ) 5.58 Efficacy ( Mw / W ) ( Results Of Effectiveness ) Photosynthetic Radiation 79.7 Photosynthesi ( W / M2 ) Capability Of Photosynthetic Radiation Which Adjusted Light Lux4.13 Flurecent Tubes ( Effectiveness Of Light Beam Area ) 5.45 400-700Nm 25.5 350-500Nm 7.26 600-700Nm 13.2 1 / - Totalflurecent Tubes 22Watt: 8 Nos. 2 / - Normal Fluorescent Lights: 1 Nos. ( F ) Humidity System:Through Micro Humidification To Create The 60-80% Accuracy + 3-5% Humidity: - Installation Of High Pressure Foggers Does Not Drip During The Function. Working Pressure: -4 Bar At This Pressure, The Average Droplet Size: 50 To 100Mm. Density: - One Fogger To 0.3M-0.4Mfor Propagation. 1. Fogger: -Cross Way Nozzle, Hanging Type = 45 Nos. Fogger Discharge Range: -7.0 Lph. 2.Pipe: -16Mm Lldpe ( Class 2 ) 3.Motor: - 1 Hp Monoblock Pump ( Isi Make ) 1 No. 4.Filter ( Screen ) :-Isi Standard = 1 No. 5.Tank: - 1000 Ltr ( Isi Make ) 1No 6.Pvc / Astmd Pipe ( 32Mmx25mm ) 12Mtr ( G ) Shading System:- Providing Of Shade Net 50%:-120Sq Mtr. ( H ) Civil Work:- Cc Foundation ( 1:3:6 ) 1’ Feet Below And 2’ Above Ground Level To Check Lateral Moments Of Water, Base Pcc 2” Thick, 9” Wide Curtain Wall ( 3Feet Height ) Duly Plastered. Earth Work Excavation Of Size 1.25’ X 125’ X 1’ = 5 Cum , Stone Soling Hand Paced 5Cum& Concreting For Structure 55M X 1M X 0.3M, Alongwith Concrete Base For Water Tank 4’X4’X3”, Buffer Room Concrete Base 2M X2m = 1Nos = 18 Cum. Concreting Of Floor ( 20Mx5mx0.10M ) And Path ( 0.75Mx55x0.10M ) :-15 Cum Earth Work Excavation Of Soil Forfloor ( 20Mx5mx0.15M ) And Path ( 0.75Mx55x0.15M ) :-21 Cum, Stone Soiling Hand Paced Infloor ( 20Mx5mx0.15M ) And Path ( 0.75Mx55x0.15M ) :-21 Cum ( I ) Electrification:- Mcb Box, Mcb, Wire, Conduit 1”, Service Line ( 15 Meter Of 16Mm, 2 Core Aluminium ) Of Standard Make :- 01 Job , P / F G I Rized Benches For Plants ( 8’ X 4’ X 2.5’ ) :Made Of G I 25Mm X25mm And 32Mm X 32Mm Square Pipe With G I Sheet18swg , Mesh ¾”Holeon Top Table Covered By Aluminum Angle 1”. , P / F Voltage Stabliser , Manual Control 20 Kva, Oil Cooled , Single Phase With Digital Volt And Amperemeter, Including Connection Wiring Complete Job , Manufacturing, Providing And Installation “Semi Hi-Tech Poly Green House Structure With Buffer Room: ”-Successful Commissioning Thereof.- Structure Size:-16M X5m X 4M: 2.5M ( L X W X Ch X Sh ) Total Working Floor Area- 80 Sqm Buffer Room Size:- 1.5M X1.5M X3m X2m ( L X W X Ch X Sh ) Single Span, Tubular Shape, Square Gi Pipe 32X32mm, 2Mm Thick Isi Standard Humidity Resistant Pipe For Maximum Indian Wind Load Conditions Capacity Of 140 / Kms / Hour, As Per Detailes Hereunder. 1-----G.I. Structure Of 32X32mm Square Pipe Of Thickness 2Mm: - Trusses:- 6 Nos. ( 15 Meter Each ) , Vertical Supports:-15 Nos. ( 3.25 Meters Each ) , Purlines ( Side Wise ) :-6Nos. ( 16 Meters Each ) , Purlin ( Roof Top ) :-3Nos. ( 16 Meters Each ) , Purlin Front / Back:-4 Nos. ( 5 Meter Each ) , Gi Door Of Size: 1 Meter X 2 Meter Of 25X25mm Gi Square Pipe 2.3Mm Thickness 1 No ( 08 Meters ) . Buffer Room Trusses:- 2 Nos. ( 5 Meter Each ) , Vertical Supports:-4 Nos. ( 3.25 Meters Each ) , Purlines ( Side Wise ) :-6Nos. ( 1.5 Meters Each ) , Purlin ( Roof Top ) :-3Nos. ( 1.5 Meters Each ) , Purlin Front:-1 No. ( 1.5 Meter Each ) , Gi Pillar Post 40X40mm:- 19 Nos. ( 0.6 Meter Each ) . 2- Aluminum Door Of Size 1 Meter X 2 Meter Made Of Pc Sheet 6Mm With Locking Arrangement And Handle :- 01 Job. 3------Humidity & Irrigation System Fogger: - 20 Nos., Lldp Pipe 16Mm:- 45 Meters, Pvc Pipe 40Mm:- 12 Meters, Filter:- 1 No., I Hp Water Pump Motor:- 1 No., Water Tank 500 Liters:- 01 No. With Fitting, Control Assembly Valve:-2Nos., Drip System Kit;- 1 No., Uv Stabilized Sagging Wire & Accessories: - 80 Meters, Timer Controller:- 1 No. 4-----Shading System Poly Film 200 Micron: - 01 Job = 300 Sqm, Insect Net ( 1.5Mx16m ( 40Mesh ) :-2 Nos. Job= 50 Sqm, Shading Net 16Mtrx6mtr:-01 Job = 96 Sqm., Aluminum Locking Profile With Screws:- 170 Meters, 5----Civil Work Earth Work Excavation For 19 No. Pits / Trenches Of Size 1’ X 1’ X 2’ = 1 Cum , Stone Soling Hand Packed 1 Cum& Concreting Alongwith Concrete Base For Water Tank 4’X4’X3”, Buffer Room Concrete Base 5’X5’X3” & Water Motor Concrete Base 1’X’1.5’X3” =1.3Cum. 6----Electrification Mcb Box, Mcb, Wire, Conduit 1”, Lamp, Holder, Service Line ( 10 Meter Of 4Mm ) Of Standard Make :- 01 Job , Manufacturing, Providing And Installation “Semi Hi-Tech Insect Net House Structure With Buffer Room: ”-Successful Commissioning Thereof.- Structure Size:-16M X5m X 4M: 2.5M ( L X W X Ch X Sh ) Total Working Floor Area- 80 Sqm Buffer Room Size:- 1.5M X1.5M X3m X2m ( L X W X Ch X Sh ) Single Span, Tubular Shape, Square Gi Pipe 32X32mm, 2Mm Thick Isi Standard Humidity Resistant Pipe For Maximum Indian Wind Load Conditions Capacity Of 140 / Kms / Hour, As Per Detailes Hereunder. 1-----G.I. Structure Of 32X32mm Square Pipe Of Thickness 2Mm: - Trusses:- 6 Nos. ( 15 Meter Each ) , Vertical Supports:-15 Nos. ( 3.25 Meters Each ) , Purlines ( Side Wise ) :-6Nos. ( 16 Meters Each ) , Purlin ( Roof Top ) :-3Nos. ( 16 Meters Each ) , Purlin Front / Back:-4 Nos. ( 5 Meter Each ) , Gi Door Of Size: 1 Meter X 2 Meter Of 25X25mm Gi Square Pipe 2.3Mm Thickness 1 No ( 08 Meters ) . Buffer Room Trusses:- 2 Nos. ( 5 Meter Each ) , Vertical Supports:-4 Nos. ( 3.25 Meters Each ) , Purlines ( Side Wise ) :-6Nos. ( 1.5 Meters Each ) , Purlin ( Roof Top ) :-3Nos. ( 1.5 Meters Each ) , Purlin Front:-1 No. ( 1.5 Meter Each ) , Gi Pillar Post 40X40mm:- 19 Nos. ( 0.6 Meter Each ) . 2- Aluminum Door Of Size 1 Meter X 2 Meter Made Of Pc Sheet 6Mm With Locking Arrangement And Handle :- 01 Job. 3------Humidity & Irrigation System Fogger: - 20 Nos., Lldp Pipe 16Mm:- 45 Meters, Pvc Pipe 40Mm:- 12 Meters, Filter:- 1 No., I Hp Water Pump Motor:- 1 No., Water Tank 500 Liters:- 01 No. With Fitting, Control Assembly Valve:-2Nos., Drip System Kit;- 1 No., Uv Stabilized Sagging Wire & Accessories: - 80 Meters, Timer Controller:- 1 No. 4-----Shading System Insect Net ( 40Mesh ) :-2 Nos. Job= 300 Sqm, Poly Film 200 Micron: - 01 Job = 20 Sqm, Aluminum Locking Profile With Screws:- 170 Meters, 5----Civil Work Earth Work Excavation For 19 No. Pits / Trenches Of Size 1’ X 1’ X 2’ = 1 Cum , Stone Soling Hand Packed 1 Cum& Concreting Alongwith Concrete Base For Water Tank 4’X4’X3”, Buffer Room Concrete Base 5’X5’X3” & Water Motor Concrete Base 1’X’1.5’X3” =1.3Cum. 6----Electrification Mcb Box, Mcb, Wire, Conduit 1”, Lamp, Holder, Service Line ( 10 Meter Of 4Mm ) Of Standard Make :- 01 Job , Manufacturing, Providing And Installation “Semi Hi-Tech Shade Net Green House Structure With Buffer Room: ”-Successful Commissioning Thereof.- Structure Size:-16M X5m X 4M: 2.5M ( L X W X Ch X Sh ) Total Working Floor Area- 80 Sqm Buffer Room Size:- 1.5M X1.5M X3m X2m ( L X W X Ch X Sh ) Single Span, Tubular Shape, Square Gi Pipe 32X32mm, 2Mm Thick Isi Standard Humidity Resistant Pipe For Maximum Indian Wind Load Conditions Capacity Of 140 / Kms / Hour, As Per Detailes Hereunder. 1-----G.I. Structure Of 32X32mm Square Pipe Of Thickness 2Mm: - Trusses:- 6 Nos. ( 15 Meter Each ) , Vertical Supports:-15 Nos. ( 3.25 Meters Each ) , Purlines ( Side Wise ) :-6Nos. ( 16 Meters Each ) , Purlin ( Roof Top ) :-3Nos. ( 16 Meters Each ) , Purlin Front / Back:-4 Nos. ( 5 Meter Each ) , Gi Door Of Size: 1 Meter X 2 Meter Of 25X25mm Gi Square Pipe 2.3Mm Thickness 1 No ( 08 Meters ) . Buffer Room Trusses:- 2 Nos. ( 5 Meter Each ) , Vertical Supports:-4 Nos. ( 3.25 Meters Each ) , Purlines ( Side Wise ) :-6Nos. ( 1.5 Meters Each ) , Purlin ( Roof Top ) :-3Nos. ( 1.5 Meters Each ) , Purlin Front:-1 No. ( 1.5 Meter Each ) , Gi Pillar Post 40X40mm:- 19 Nos. ( 0.6 Meter Each ) . 2- Aluminum Door Of Size 1 Meter X 2 Meter Made Of Pc Sheet 6Mm With Locking Arrangement And Handle :- 01 Job. 3------Humidity & Irrigation System Fogger: - 20 Nos., Lldp Pipe 16Mm:- 45 Meters, Pvc Pipe 40Mm:- 12 Meters, Filter:- 1 No., I Hp Water Pump Motor:- 1 No., Water Tank 500 Liters:- 01 No. With Fitting, Control Assembly Valve:-2Nos., Drip System Kit;- 1 No., Uv Stabilized Sagging Wire & Accessories: - 80 Meters, Timer Controller:- 1 No. 4-----Shading System Shading Net 16Mtrx6mtr:-01 Job = 300 Sqm., Poly Film 200 Micron: - 01 Job = 20 Sqm, Aluminum Locking Profile With Screws:- 170 Meters, 5----Civil Work Earth Work Excavation For 19 No. Pits / Trenches Of Size 1’ X 1’ X 2’ = 1 Cum , Stone Soling Hand Packed 1 Cum& Concreting Alongwith Concrete Base For Water Tank 4’X4’X3”, Buffer Room Concrete Base 5’X5’X3” & Water Motor Concrete Base 1’X’1.5’X3” =1.3Cum. 6----Electrification Mcb Box, Mcb, Wire, Conduit 1”, Lamp, Holder, Service Line ( 10 Meter Of 4Mm ) Of Standard Make :- 01 Job , Supply Of Uvs Poly Fill Micronblack / Coloured Sheets Of 500Micron Of Standard Make , I ) Optional Item:-1.Collapsible Over Head Top Of Size 0.5 Mtr X 20 Mtr And Sides Of Windows ( 1+1 ) Of Size 1Mtr X 18 Mtr Each Side Fitted With Gare System ( Liftable Separately One By One-Three Pieces ) Fabricated Out Of Gi 25Mm Pipe With Pc Sheet Of Thickness 6Mm. 1 Complete Job.=46 Sqmts. , Supply Of Green House Steel Structure ( Fabricated Pieces ) For Over Allsizeof Theg / House8 X 5 Meters As Per Specifications As Under: 8’ Height ( Consisting Of 11 Arches ) Duly Fabricated Out Of 31 / 32 Mm Round Conduit Pipe 18 Gauge With 1” Square Pipe Of 18 Guage For Doors & Top With Belt 2.5’ Longof 25X5mm / 25X6mm Flat Iron Including 22 Nos. Side Legs 2.5’ Each Leg Of 18 Guage C / Pipewith Internal Pipe Of 20Mm Dia 6” Pieces 22 Nos.Including22 Nos. Of 4” Pieces Of Flat Iron 25X5mm / 25X6mm. 31 / 32Mm 18 Guage Conduit Pipe As Purlins 5 Nos. 8 Meter Longeach And A Centre Support Pole / Post Of 8’ Height, All Fabricated Pieces Duly Red Oxide Primed Including Cost Of Nuts, Bolts & Other Necessary Required Hardware Items Complete Job. , Supply Of Green House Structure ( Fabricated Peices ) Made Out Of G.I Pipeof Size 10 X4 Meter , Height 8 Pipe 31 ( Od ) 18 ( Swg ) 1. Arch 11 Nos2. Purlins 05 No.3. Grouting Rod Length 2’X6” 22 No. 4. Central Support 8’ Length =2No5.Doors 2’X6”X5’ Fitted With Arch Made Of 1”X1”89 Section Pipe 6.Windows 2’X2’ 89 Sqm 1”X1” Pipe 7.Complete Set Of Net And Bolts 8. Hardware Items Like Hinges, Sheet Items Etc Weight ( 143To 145 Kgs )

Key Value

Document Fees
INR 25 /-
EMD
INR 5000.0 /-
Tender Value
Refer document

BOQ Items

Description: Rate Contract for Hi-TECH/Semi-Hitech Green Houses and Related Structures/Works
Sl. No. Item Description
1Manufacturing, providing and installation of “HI –TechGreen House-cum- Mist Chamber structure soft soil with buffer room ”-Successful Commissioning thereof. Technical /Operational Parameters Structure Size (Working area) : 20m x5mx4mx 2.5 m (L x W x CH: SH) Total area100Sqm. Buffer Room- 2m x 2m x 3m x2m (L x W x CH : SH) provided with air curtain (A).G.I. Structure 20 m x 5m with buffer room 2m x 2m: 1.GI Pipe(50x50mm) Specification: a/ GI Pipe ISI Standard: - IS 1239 B Class construction use. b/- Thickness: - 2mm c/- GI coat ISI standard: - IS 4736-1968/ISO65-1973 d/- Weight 50mm x50mm: - 20Kg/length of 20’. GI (50x50mm) ISI standard IS 1239 class B anti-corrosive, humidity resistant pipe with IS 4736-1968/ISO 65-1973 Zinc coat as approved for maximum indian wind load conditions, structural trusses be provided for absolute strengthwind load 160km/hr (BL3-P rigid, wind resistant frame.) Reinforced rigid frame walls and ceiling sealed with internal shell. a/-Trusses : -50mm x 50mm b/-Vertical Supports50mm x 50mm c/-Purline50mm x 50mm Trusses:- 11 Nos. (15 meter each),Vertical supports:-23 Nos.(3 meters each), Centre Vertical supports:-22 Nos.(2 meters each),Purlines (side wise):-4Nos.(20 meters each),Purlin (roof top):-5Nos. (20 meters each), Purlin front/Back:-4 Nos. (5 meter each) Buffer room Trusses:- 2 Nos. (5 meter each),Vertical supports:-8 Nos.(3 meters each), Purlines (side wise):-6Nos.(2 meters each),Purlin (roof top):-3Nos. (2 meters each), Purlin front & Back:-2 No. (2 meter each) :- 2-Aluminium strips/profile(Side & top) 2” -Weight 0.35 Kg / mtr Perforated Anti dust :-300mtr 3-Aluminium Angle 2”x2”(front& Back)- Weight 0.35 Kg / mtr Perforated Anti dust :-100mtr 4-Aluminium Door of size -2m x 1m of aluminum section with polycarbonate sheet 6mm thick as cladding material with proper locking system and hydraulic door closeralso be provided:- 02 Nos Job. 5-Aluminium Windows of size – 1mtr x 0.5mtr of aluminum section with polycarbonate sheet 6mm thick 6 Nos 6-Poly carbonate sheet 8mm; Specifications Multi walled Impact resistant, Energy saving. Unbreakable, (Impact resistant upon thickness and color selection. Excellent Weather Resistance: 10 yearswarranty (protection against the damaging effects of UV radiation in sunlight) Safe Fire Performance:self-extinguishing and difficult to ignite. Light Weight:Weight ranging from 1.3 Kgs/Sqm for 6mm. Sound Insulation as Per DIN 52210 ( dB) : 18 dB Dura Tuf Make :- 3080 Sq feet. 7- Air curtain: Size: 3’ wide heavy duty, cabinets of AIR curtain are made of cold rolled Mild Steel Sheets. The blowers are made of high quality Alu. sheets with ½ HP motor & double blower system, powder coated finish at pre entry point, entry with automatic main ON /OFF operation at the time of door opening / closing:- 1 Nos. (B) MICROPROCESSOR PHOTOSYNTHESIS MONITOR PANEL: Heating, Cooling & Humidity Microclimatic Temperature Controller Specifications: Real time microprocessor based PID Controller , 4 digit LED display for displaying measured (14mm, 8mm) / displaying settings, soft touch operation , platinum sensor probe Pt-100 set point lock within the setting panel to protect setting changes, level lock to ensure that the parameter can be read but cannot be changed, sensor failure indication, display resolution 0.1 % C, automatic hysteresis control. Wide selectable temperature ranges from 0%. Accuracy + 0.1 % C, 4.4 KVA load can be directly connected to the powered output, input – 200-240 VAC, 50 Hz. Single phases. , Ambient 5 degree -50 degree C, RH up to 90%. Microclimatic Humidity Controller Specification: Microprocessor based, on /off control for humidifying / Dehum, Hysteresis / Differential 1% - 9%, Delay timer 0-240 sec, direct / Reverse selectable, lock functions to prevent miss operating, feather touch operation, fast response sensor – line resistance < 100, Display Accuracy – indicating value + 0.2 % + 0.2 % + 1 digit. Piltz / Cyclic Timer for Humidity: Specific for fogging, misting system, controlled by timer. To reduce water logging condition in the transgenic greenhouse each. Specification: 0.999 Min / sec on, 0-999 Min/ Sec off, automatic cycling accuracy quartz, power output can be directly drive misting unit load up to 4.4 KVA, input 200 V to 240 VA.C, phase- single, 50 Hz, Ambient 4 degree C to 50 degree C, RH u[to 90%:- 1 Nos. (C) Evaporative Cooling System (ECS): 1.Pad size: (16ft x5ftx4” thick)With cellulose pads to acquire proper CFM of air movement per sq.ft of area will be provided.. Even water delivery through distribution pipe will be ensured. Technical Parameters of Cellulose Pad: Paper ambient condition 25°- C -45 °- C Estimated cooling load: 101,520 BTUs/Hrs. Total water flow 7.56 LPM per sq. ft.of the top pad surface. Bleed of equal to 10% of total water rate. Eco friendly.High saturation efficiency Self-cleaning feature No setting or Shrinkage of product Low pressure drop characteristics. Impregnation makes the material stiff and self-supporting Make: (Standard) COLLING PAD ACCESSORIES:- Tray Material: - Tray Side, top etc. Over: - 20mm PVC Drain: - 32 mm standard PVC. Construction Material: 20 GA GI / AI Sheets: Tray Side, top etc. Cooling Media: 100 mm thick at velocity of 1 to 3 Micro Sleves to give Efficiency from 60 to 95%. 2.Filtration : screen filter. 3.Miscellaneous: Fasteners, Galvanized, Rivet- Aluminum. 4.Pump : 1 Hp Monoblock ( Standard make) =1No 5.Co-Axial Flow fan 48”:2 Nos 6.40 x40 Mesh ` : For extra protection from deserts sand/ dust fitted (D) Heating System: - Providing Heavy duty forced heat convection system which is ideal for heating in biotech work and green house. Automatic thermal cut off device, Biotech Grade 2.5KW. it has ISI standard make heating element and ISI standard 900rpm speed fan. Input 200-240 VAC, 50 HZ, Single phase.No of 1.Heaters-4Nos. (E) Lighting System:- Providing of 8 Nos of Flurecent Tubes High Luminous of Standard make. These lamps are provided for increasing day length with specific wave length & spectrum and using in green house globally for best production in floriculture/ Horticulture/ Forestry etc Technical Specification of PAR Lamps: Lamp Wattage (W) 36 Luminous Flux1350 Luminous Efficacy (Lm/U) 19.3 Photosynthesis Watt (W) (photosynthetic effects of Lamp)5.58 Efficacy (mw/w) (Results of Effectiveness) Photosynthetic radiation 79.7 Photosynthesi (w/m2) Capability of Photosynthetic radiation which adjusted light lux4.13 Flurecent tubes (Effectiveness of light Beam area)5.45 400-700nm 25.5 350-500nm 7.26 600-700nm 13.2 1/- TotalFlurecent Tubes 22Watt: 8 Nos. 2/- Normal fluorescent lights: 1 Nos. (F) Humidity System:Through Micro Humidification to create the 60-80% accuracy + 3-5% Humidity: - Installation of High Pressure foggers does not drip during the function. Working pressure: -4 bar at this pressure, the average droplet size: 50 to 100mm. Density: - One fogger to 0.3m-0.4mfor propagation. 1. Fogger: -Cross way nozzle, hanging type = 45 Nos. Fogger discharge range: -7.0 LPH. 2.Pipe: -16mm LLDPE (Class 2) 3.Motor: - 1 HP monoblock pump (ISI Make) 1 No. 4.Filter (Screen) :-ISI Standard = 1 No. 5.Tank: - 1000 ltr (ISI make) 1No 6.PVC/ ASTMD pipe (32mmx25mm) 12mtr (G) Shading System:- Providing of shade net 50%:-120sq mtr. (H) Civil Work:- CC foundation (1:3:6)1’ feet below and 2’ above ground level to check lateral moments of water, base PCC 2” thick, 9” wide curtain wall ( 3feet height) duly plastered. Earth work excavation of size 1.25’ x 125’ x 1’ = 5 cum , Stone soling hand paced 5cum& Concreting For Structure 55m x 1m x 0.3m, alongwith concrete base for water tank 4’x4’x3”, Buffer Room Concrete Base 2m x2m = 1Nos = 18 cum. (I) Electrification:- MCB Box, MCB, wire, conduit 1”,Service Line(15 meter of 16mm, 2 core aluminium) of standard make :-01 job
2Manufacturing, providing and installation of “HI –TechGreen House-cum- Mist Chamber structure with buffer room, Hard Soil (Concrete Floor).”-Successful Commissioning thereof. Technical /Operational Parameters Structure Size (Working area) : 20m x5mx4mx 2.5 m (L x W x CH: SH) Total area100Sqm. Buffer Room- 2m x 2m x 3m x2m (L x W x CH : SH) provided with air curtain (A).G.I. Structure 20 m x 5m with buffer room 2m x 2m: 1.GI Pipe(50x50mm) Specification: a/ GI Pipe ISI Standard: -IS 1239 B Class construction use. b/- Thickness: - 2mm c/- GI coat ISI standard: -IS 4736-1968/ISO65-1973 d/- Weight 50mm x50mm: -21Kg/length of 20’. GI (50x50mm) ISI standard IS 1239 class B anti-corrosive, humidity resistant pipe with IS 4736-1968/ISO 65-1973 Zinc coat as approved for maximum indian wind load conditions, structural trusses be provided for absolute strengthwind load 160km/hr (BL3-P rigid, wind resistant frame.) Reinforced rigid frame walls and ceiling sealed with internal shell. a/-Trusses : -50mm x 50mm b/-Vertical Supports50mm x 50mm c/-Purline50mm x 50mm Trusses:- 11 Nos. (15 meter each),Vertical supports:-23 Nos.(3 meters each), Centre Vertical supports:-22 Nos.(2 meters each),Purlines (side wise):-4Nos.(20 meters each),Purlin (roof top):-5Nos. (20 meters each), Purlin front/Back:-4 Nos. (5 meter each) Buffer room Trusses:- 2 Nos. (5 meter each),Vertical supports:-8 Nos.(3 meters each), Purlines (side wise):-6Nos.(2 meters each),Purlin (roof top):-3Nos. (2 meters each), Purlin front & Back:-2 No. (2 meter each) :- 2-Aluminium strips/profile(Side & top) 2” -Weight 0.35 Kg / mtr Perforated Anti dust :-300mtr 3-Aluminium Angle 2”x2”(front& Back)- Weight 0.35 Kg / mtr Perforated Anti dust :-100mtr 4-Aluminium Door of size -2m x 1m of aluminum section with polycarbonate sheet 6mm thick as cladding material with proper locking system and hydraulic door closeralso be provided:- 02 Nos Job. 5-Aluminium Windows of size – 1mtr x 0.5mtr of aluminum section with polycarbonate sheet 6mm thick 6 Nos 6-Poly carbonate sheet 8mm; Specifications Multi walled Impact resistant, Energy saving. Unbreakable, (Impact resistant upon thickness and color selection. Excellent Weather Resistance: 10 yearswarranty (protection against the damaging effects of UV radiation in sunlight) Safe Fire Performance:self-extinguishing and difficult to ignite. Light Weight:Weight ranging from 1.3 Kgs/Sqm for 6mm. Sound Insulation as Per DIN 52210 ( dB) : 18 dB Dura Tuf Make :- 3080 Sq feet. 7- Air curtain: Size: 3’ wide heavy duty, cabinets of AIR curtain are made of cold rolled Mild Steel Sheets. The blowers are made of high quality Alu. sheets with ½ HP motor & double blower system, powder coated finish at pre entry point, entry with automatic main ON /OFF operation at the time of door opening / closing:- 1 Nos. (B) MICROPROCESSOR PHOTOSYNTHESIS MONITOR PANEL: Heating, Cooling & Humidity Microclimatic Temperature Controller Specifications: Real time microprocessor based PID Controller , 4 digit LED display for displaying measured (14mm, 8mm) / displaying settings, soft touch operation , platinum sensor probe Pt-100 set point lock within the setting panel to protect setting changes, level lock to ensure that the parameter can be read but cannot be changed, sensor failure indication, display resolution 0.1 % C, automatic hysteresis control. Wide selectable temperature ranges from 0%. Accuracy + 0.1 % C, 4.4 KVA load can be directly connected to the powered output, input – 200-240 VAC, 50 Hz. Single phases. , Ambient 5 degree -50 degree C, RH up to 90%. Microclimatic Humidity Controller Specification: Microprocessor based, on /off control for humidifying / Dehum, Hysteresis / Differential 1% - 9%, Delay timer 0-240 sec, direct / Reverse selectable, lock functions to prevent miss operating, feather touch operation, fast response sensor – line resistance < 100, Display Accuracy – indicating value + 0.2 % + 0.2 % + 1 digit. Piltz / Cyclic Timer for Humidity: Specific for fogging, misting system, controlled by timer. To reduce water logging condition in the transgenic greenhouse each. Specification: 0.999 Min / sec on, 0-999 Min/ Sec off, automatic cycling accuracy quartz, power output can be directly drive misting unit load up to 4.4 KVA, input 200 V to 240 VA.C, phase- single, 50 Hz, Ambient 4 degree C to 50 degree C, RH u[to 90%:- 1 Nos. (C) Evaporative Cooling System (ECS): 1.Pad size: 16ft x5ftx4” thick)With cellulose pads to acquire proper CFM of air movement per sq.ft of area will be provided.. Even water delivery through distribution pipe will be ensured. Technical Parameters of Cellulose Pad: Paper ambient condition 25°- C -45 °- C Estimated cooling load: 101,520 BTUs/Hrs. Total water flow 7.56 LPM per sq. ft.of the top pad surface. Bleed of equal to 10% of total water rate. Eco friendly.High saturation efficiency Self-cleaning feature No setting or Shrinkage of product Low pressure drop characteristics. Impregnation makes the material stiff and self-supporting Make: (Standard) COLLING PAD ACCESSORIES:- Tray Material: - Tray Side, top etc. Over: - 20mm PVC Drain: - 32 mm standard PVC. Construction Material: 20 GA GI / AI Sheets: Tray Side, top etc. Cooling Media: 100 mm thick at velocity of 1 to 3 Micro Sleves to give Efficiency from 60 to 95%. 2.Filtration : screen filter. 3.Miscellaneous: Fasteners, Galvanized, Rivet- Aluminum. 4.Pump : 1 Hp Monoblock ( Standard make) =1No 5.Co-Axial Flow fan 48”:2 Nos 6.40 x40 Mesh ` : For extra protection from deserts sand/ dust fitted (D) Heating System: - Providing Heavy duty forced heat convection system which is ideal for heating in biotech work and green house. Automatic thermal cut off device, Biotech Grade 2.5KW. it has ISI standard make heating element and ISI standard 900rpm speed fan. Input 200-240 VAC, 50 HZ, Single phase.No of 1.Heaters-4Nos. (E) Lighting System:- Providing of 8 Nos of Flurecent Tubes High Luminous of Standard make. These lamps are provided for increasing day length with specific wave length & spectrum and using in green house globally for best production in floriculture/ Horticulture/ Forestry etc Technical Specification of PAR Lamps: Lamp Wattage (W) 36 Luminous Flux1350 Luminous Efficacy (Lm/U) 19.3 Photosynthesis Watt (W) (photosynthetic effects of Lamp)5.58 Efficacy (mw/w) (Results of Effectiveness) Photosynthetic radiation 79.7 Photosynthesi (w/m2) Capability of Photosynthetic radiation which adjusted light lux4.13 Flurecent tubes (Effectiveness of light Beam area)5.45 400-700nm 25.5 350-500nm 7.26 600-700nm 13.2 1/- TotalFlurecent Tubes 22Watt: 8 Nos. 2/- Normal fluorescent lights: 1 Nos. (F) Humidity System:Through Micro Humidification to create the 60-80% accuracy + 3-5% Humidity: - Installation of High Pressure foggers does not drip during the function. Working pressure: -4 bar at this pressure, the average droplet size: 50 to 100mm. Density: - One fogger to 0.3m-0.4mfor propagation. 1. Fogger: -Cross way nozzle, hanging type = 45 Nos. Fogger discharge range: -7.0 LPH. 2.Pipe: -16mm LLDPE (Class 2) 3.Motor: - 1 HP monoblock pump (ISI Make) 1 No. 4.Filter (Screen) :-ISI Standard = 1 No. 5.Tank: - 1000 ltr (ISI make) 1No 6.PVC/ ASTMD pipe (32mmx25mm) 12mtr (G) Shading System:- Providing of shade net 50%:-120sq mtr. (H) Civil Work:- CC foundation (1:3:6)1’ feet below and 2’ above ground level to check lateral moments of water, base PCC 2” thick, 9” wide curtain wall ( 3feet height) duly plastered. Earth work excavation of size 1.25’ x 125’ x 1’ = 5 cum , Stone soling hand paced 5cum& Concreting For Structure 55m x 1m x 0.3m, alongwith concrete base for water tank 4’x4’x3”, Buffer Room Concrete Base 2m x2m = 1Nos = 18 cum. Concreting of Floor(20mx5mx0.10m) and path (0.75mx55x0.10m):-15 cum Earth work excavation of Soil forFloor(20mx5mx0.15m) and path (0.75mx55x0.15m):-21 cum, Stone soiling hand paced inFloor(20mx5mx0.15m) and path (0.75mx55x0.15m):-21 cum (I) Electrification:- MCB Box, MCB, wire, conduit 1”,Service Line(15 meter of 16mm, 2 core aluminium) of standard make :- 01 job
3P/F G I Rized benches for Plants(8’ x 4’ x 2.5’) :Made of G I 25mm x25mm and 32mm x 32mm Square Pipe with G I sheet18swg , Mesh ¾”holeon top table covered by Aluminum angle 1”.
4P/F Voltage stabliser ,Manual control 20 KVA, oil Cooled , Single phase with digital volt and amperemeter, including connection wiring complete job
5Manufacturing, providing and installation “Semi Hi-Tech Poly Green house Structure with Buffer room: ”-Successful Commissioning thereof.- Structure Size:-16m x5m x 4m: 2.5m ( L x W x CH x SH) Total Working floor area- 80 sqm Buffer room size:- 1.5m x1.5m x3m x2m( L x W x CH x SH) Single Span, tubular shape, Square GI Pipe 32x32mm, 2mm thick ISI Standard humidity resistant pipe for maximum Indian wind load conditions capacity of 140/Kms/hour, as per detailes hereunder. 1-----G.I. Structure of 32x32mm Square Pipe of thickness 2mm: - Trusses:- 6 Nos. (15 meter each),Vertical supports:-15 Nos.(3.25 meters each), Purlines (side wise):-6Nos.(16 meters each),Purlin (roof top):-3Nos. (16 meters each), Purlin front/Back:-4 Nos. (5 meter each), GI Door of Size: 1 meter x 2 meter of 25x25mm GI Square pipe 2.3mm thickness 1 No( 08 meters). Buffer room Trusses:- 2 Nos. (5 meter each),Vertical supports:-4 Nos.(3.25 meters each), Purlines (side wise):-6Nos.(1.5 meters each),Purlin (roof top):-3Nos. (1.5 meters each), Purlin front:-1 No. (1.5 meter each), GI Pillar Post 40x40mm:- 19 Nos. (0.6 meter each). 2- Aluminum Door of size 1 meter x 2 meter made of PC Sheet 6mm with locking arrangement and handle :- 01 Job. 3------Humidity & Irrigation System Fogger: - 20 Nos., LLDP Pipe 16mm:- 45 meters, PVC Pipe 40mm:- 12 meters, Filter:- 1 No., I HP Water Pump Motor:- 1 No., Water tank 500 liters:- 01 No. with fitting, Control Assembly Valve:-2Nos., Drip System Kit;- 1 No., UV Stabilized sagging wire & accessories: - 80 meters, timer Controller:- 1 No. 4-----Shading System Poly film 200 Micron: - 01 job = 300 Sqm, Insect Net (1.5mx16m(40Mesh):-2 Nos. job= 50 Sqm, Shading Net 16mtrx6mtr:-01 job = 96 sqm., Aluminum locking profile with screws:- 170 meters, 5----Civil work Earth work excavation for 19 No. pits/trenches of size 1’ x 1’ x 2’ = 1 cum , Stone soling hand packed 1 cum& concreting alongwith concrete base for water tank 4’x4’x3”, Buffer Room Concrete Base 5’x5’x3” & Water Motor Concrete base 1’x’1.5’x3” =1.3Cum. 6----Electrification MCB Box, MCB, wire, conduit 1”, lamp, Holder, Service Line(10 meter of 4mm) of standard make :- 01 job
6Manufacturing, providing and installation “Semi Hi-Tech Insect Net house Structure with Buffer room: ”-Successful Commissioning thereof.- Structure Size:-16m x5m x 4m: 2.5m ( L x W x CH x SH) Total Working floor area- 80 sqm Buffer room size:- 1.5m x1.5m x3m x2m( L x W x CH x SH) Single Span, tubular shape, Square GI Pipe 32x32mm, 2mm thick ISI Standard humidity resistant pipe for maximum Indian wind load conditions capacity of 140/Kms/hour, as per detailes hereunder. 1-----G.I. Structure of 32x32mm Square Pipe of thickness 2mm: - Trusses:- 6 Nos. (15 meter each),Vertical supports:-15 Nos.(3.25 meters each), Purlines (side wise):-6Nos.(16 meters each),Purlin (roof top):-3Nos. (16 meters each), Purlin front/Back:-4 Nos. (5 meter each), GI Door of Size: 1 meter x 2 meter of 25x25mm GI Square pipe 2.3mm thickness 1 No( 08 meters). Buffer room Trusses:- 2 Nos. (5 meter each),Vertical supports:-4 Nos.(3.25 meters each), Purlines (side wise):-6Nos.(1.5 meters each),Purlin (roof top):-3Nos. (1.5 meters each), Purlin front:-1 No. (1.5 meter each), GI Pillar Post 40x40mm:- 19 Nos. (0.6 meter each). 2- Aluminum Door of size 1 meter x 2 meter made of PC Sheet 6mm with locking arrangement and handle :- 01 Job. 3------Humidity & Irrigation System Fogger: - 20 Nos., LLDP Pipe 16mm:- 45 meters, PVC Pipe 40mm:- 12 meters, Filter:- 1 No., I HP Water Pump Motor:- 1 No., Water tank 500 liters:- 01 No. with fitting, Control Assembly Valve:-2Nos., Drip System Kit;- 1 No., UV Stabilized sagging wire & accessories: - 80 meters, timer Controller:- 1 No. 4-----Shading System Insect Net (40Mesh):-2 Nos. job= 300 Sqm, Poly film 200 Micron: - 01 job = 20 Sqm,Aluminum locking profile with screws:- 170 meters, 5----Civil work Earth work excavation for 19 No. pits/trenches of size 1’ x 1’ x 2’ = 1 cum , Stone soling hand packed 1 cum& concreting alongwith concrete base for water tank 4’x4’x3”, Buffer Room Concrete Base 5’x5’x3” & Water Motor Concrete base 1’x’1.5’x3” =1.3Cum. 6----Electrification MCB Box, MCB, wire, conduit 1”, lamp, Holder, Service Line(10 meter of 4mm) of standard make :- 01 job
7Manufacturing, providing and installation “Semi Hi-Tech Shade Net Green house Structure with Buffer room: ”-Successful Commissioning thereof.- Structure Size:-16m x5m x 4m: 2.5m ( L x W x CH x SH) Total Working floor area- 80 sqm Buffer room size:- 1.5m x1.5m x3m x2m( L x W x CH x SH) Single Span, tubular shape, Square GI Pipe 32x32mm, 2mm thick ISI Standard humidity resistant pipe for maximum Indian wind load conditions capacity of 140/Kms/hour, as per detailes hereunder. 1-----G.I. Structure of 32x32mm Square Pipe of thickness 2mm: - Trusses:- 6 Nos. (15 meter each),Vertical supports:-15 Nos.(3.25 meters each), Purlines (side wise):-6Nos.(16 meters each),Purlin (roof top):-3Nos. (16 meters each), Purlin front/Back:-4 Nos. (5 meter each), GI Door of Size: 1 meter x 2 meter of 25x25mm GI Square pipe 2.3mm thickness 1 No( 08 meters). Buffer room Trusses:- 2 Nos. (5 meter each),Vertical supports:-4 Nos.(3.25 meters each), Purlines (side wise):-6Nos.(1.5 meters each),Purlin (roof top):-3Nos. (1.5 meters each), Purlin front:-1 No. (1.5 meter each), GI Pillar Post 40x40mm:- 19 Nos. (0.6 meter each). 2- Aluminum Door of size 1 meter x 2 meter made of PC Sheet 6mm with locking arrangement and handle :- 01 Job. 3------Humidity & Irrigation System Fogger: - 20 Nos., LLDP Pipe 16mm:- 45 meters, PVC Pipe 40mm:- 12 meters, Filter:- 1 No., I HP Water Pump Motor:- 1 No., Water tank 500 liters:- 01 No. with fitting, Control Assembly Valve:-2Nos., Drip System Kit;- 1 No., UV Stabilized sagging wire & accessories: - 80 meters, timer Controller:- 1 No. 4-----Shading System Shading Net 16mtrx6mtr:-01 job = 300 sqm., Poly film 200 Micron: - 01 job = 20 Sqm, Aluminum locking profile with screws:- 170 meters, 5----Civil work Earth work excavation for 19 No. pits/trenches of size 1’ x 1’ x 2’ = 1 cum , Stone soling hand packed 1 cum& concreting alongwith concrete base for water tank 4’x4’x3”, Buffer Room Concrete Base 5’x5’x3” & Water Motor Concrete base 1’x’1.5’x3” =1.3Cum. 6----Electrification MCB Box, MCB, wire, conduit 1”, lamp, Holder, Service Line(10 meter of 4mm) of standard make :- 01 job
8Supply of UVS Poly fill MicronBlack /Coloured Sheets of 500micron of standard make
9I) Optional Item:-1.Collapsible over head top of size 0.5 mtr x 20 mtr and sides of windows(1+1)of size 1mtr x 18 mtr each side fitted with gare system (liftable separately one by one-three pieces ) fabricated out of GI 25mm pipe with PC Sheet of thickness 6mm. 1 complete job.=46 Sqmts.
10Supply of Green House Steel Structure (fabricated pieces) for over allsizeof theG/House8 x 5 meters as per specifications as under: 8’ height (consisting of 11 Arches ) duly Fabricated out of 31/ 32 mm round conduit pipe 18 gauge with 1” Square pipe of 18 guage for doors & top with belt 2.5’ longof 25x5mm/25x6mm flat iron including 22 Nos. side legs 2.5’ each leg of 18 guage c/pipewith internal pipe of 20mm dia 6” pieces 22 Nos.including22 Nos. of 4” pieces of flat iron 25x5mm/25x6mm. 31/32mm 18 guage conduit pipe as purlins 5 Nos. 8 meter longeach and a centre support pole/ post of 8’ height, all fabricated pieces duly red oxide primed including cost of nuts, bolts & other necessary required hardware items complete job.
11Supply of Green House Structure (fabricated peices) made out of G.I Pipeof size 10 x4 meter ,height 8" pipe 31(OD)18 (SWG)1. Arch 11 Nos2. Purlins 05 No.3. Grouting Rod length 2’x6” 22 No. 4. Central Support 8’ Length =2No5.Doors 2’x6”x5’ fitted with arch made of 1”x1”89 section Pipe 6.windows 2’x2’ 89 sqm 1”x1” pipe 7.complete set of net and bolts 8. hardware items like hinges, sheet items etc weight (143to 145 Kgs)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail