}

Various Civil Works And Maintenance Works In Sub Division I Of Division Ii-B ( Arc ) Civil WorksClearing and grubbing road land including uprooting rank vegetation, grass, brush, shrubs, saplings and trees of girth upto 300mm, removal of stumps, dispo, kota-Rajasthan

Urban Improvement Trust-UIT has published Various Civil Works And Maintenance Works In Sub Division I Of Division Ii-B ( Arc ) Civil WorksClearing and grubbing road land including uprooting rank vegetation, grass, brush, shrubs, saplings and trees of girth upto 300mm, removal of stumps, dispo. Submission Date for this Tender is 06-06-2022. Coats and Jackets Tenders in kota Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

32265199
Various Civil Works And Maintenance Works In Sub Division I Of Division Ii-B ( Arc ) Civil WorksClearing and grubbing road land including uprooting rank vegetation, grass, brush, shrubs, saplings and trees of girth upto 300mm, removal of stumps, dispo
Open Tender
Indian
Rajasthan
kota
06-06-2022

Tender Details

Various Civil Works And Maintenance Works In Sub Division I Of Division Ii-B ( Arc ) Civil WorksClearing and grubbing road land including uprooting rank vegetation, grass, brush, shrubs, saplings and trees of girth upto 300mm, removal of stumps, disposal of unserviceable Material and stacking of serviceable Material upto 1000m from road boundary. (MoRTH Specification : Clause 201).BY MANUAL MEANS : In area of Light Jungle 2 Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. 3 Silt clearance of drains, channels and canals with lift 1.5 Mtr. and lead up to 50 Mtr. 4 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils 5 Add extra over item no. 1.8 and 1.9 (Sechedule Item No-1) for every additional lift of 1.5 m or part thereof : 6 Above 1.50 To 3.00M 7 M-35,60mm thick to be used in light traffic (Light traffic is defined as a daily traffic up to 150 commercial vehicles exceeding 30 KN laden weight, or an wquivalent up to 0.5 million standerd axles (MSA) for a design life of 20 years (A standerd axle is defind as a single axle load of 81.6 KN ) like pedestrain plazes, shopping complexes ramps, car Parks, office drveways , housing colonies , office complexes , rural roads with low volume traffic ,fram houses, beach sites, tourist resorts, local authority footwys ,residential roads, etc. 8 Category Bdenated only two side like I,Z,T shape etc. as per IRC SP 63:2004 9 Random rubble dry stone Kharanja under floor. 10 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 11 M10 grade Nominal Mix, 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 12 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix 13 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor Three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix 14 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor Three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix 15 Centering and Shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 16 Anti termite treatment of floor using Imidacloprid 30.5% EC non repellent, odorless, low dose, environimentally safe terniticide with rapid action non corrosive stain free manufactured by Bayer or equivalent company by drilling 12mm diameter holes 300mm apart injecting the emulsion as specified by the manufacturer and plugging with cement mortar 1:2 ( 1 cement : 2 coarse sand) in the whole floor area DPE 12mm dia termitube system with required number of junction boxes are to be installed. The termitube will run all along the perimeter wall both inside and outside. In the middle area the termitube to be installed at an interval of 1.00 Mtr. or less both ways as required with sufficient number of junction boxes to pump the emulsion. After successful testing of termitube, pesticide emulsion of imidacloprid 30.5% EC mixed with water in the ration of 1:474 will be pumped by a motorized spray pump from the junction box in specified manner. The plinth area of the area treated will be measured for payment. 17 Centering & shuttering with plywood or steel Plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor Three level for : 18 Columns, pillars, posts and struts etc. 19 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: 20 Cement Mortar 1:6 ( 1-Cement : 6-Sand). 21 Cement Mortar 1:4 ( 1-Cement : 4-Sand). 22 Cement Mortar 1:3 ( 1-Cement : 3-Sand). 23 Random Rubble stone masonry with hard stone in superstructure aboveplinth level and upto Three Levelabove 30cm. thick walls in : 24 Cement Mortar 1:3 ( 1-Cement : 3-Sand). 25 Cement Mortar 1:4 ( 1-Cement : 4-Sand). 26 Cement Mortar 1:6 ( 1-Cement : 6-Sand). 27 Pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) : 28 Flush / Ruled/ Struck or weathered pointing. 29 Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete and not applying 2 coats of hot bitumen complete as per specifications. 75mm thick 30 50mm thick 31 75 mm thick 32 Centering & shuttering with plywood or steel Plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor Three level for : 33 Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 34 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor Three level. 35 Thermo-mechanically Treated bars (Conforming of relevent IS code) 36 Flyash Flyash Brick work with flyash Flyash Bricks of class designation 75 in superstructure above plinth level upto floor Three Level in all shapes and sizes in : 37 Cement mortar 1 : 4 (1 cement : 4 coarse sand) 38 Cement mortar 1 : 6 (1 cement : 6 coarse sand) 39 Half Flyash Brick masonry in foundation & plinth using Flyash Bricks of designation 75 40 Cement mortar 1 : 4 (1 cement : 4 coarse sand) 41 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 42 12mm thick. 43 20mm thick. 44 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 45 Making grooves as per design in plaster 10mm to 20mm wide. 46 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 47 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : 48 Two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 49 Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. 50 New Work 51 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 52 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 53 Two or more coats on new work 54 150cm high fencing with angle iron 50x50x6mm. placed at every 3Mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with 50x50x6mm. angle iron provided with 6 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete. 55 Grading roof for water proofing treatment withwater proffing compound 56 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 57 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : 58 Profile B 59 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 30 mm thick . 60 Decorative teak veneer both side 61 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). : For fixed portion 62 Polyester Powder coating aluminum( minimum thickness of powder coating 50 micron) 63 Providing and fixing of Plastic shutter Infill made from extruded multi chamber hollow P.V.C. section having cross section of 200 x 20 x 1 mm and shutter frame made from extrude P.V.C. section in the configuration of double walled C section having an overall cross section of 40 x 37 mm and door fittings such as hinges, aldrop, Handles, stopper, locking bolt will be provided. 64 Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Partly fixed and partly openable [ fixed area not to exceed 33%] 65 For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). 66 Polyester Powder coating aluminum( minimum thickness of powder coating 50 micron) 67 Providing and Fixing superior quality like Hardvyn or equivalent hydraulic door closure. 68 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 69 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 70 Providing and fixing 15 to 20 mm thick Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12 mm (Av.) thick base of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointing with white cement mortar 1 : 2 (1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of : 71 Good quality South Black Above 3601 Cm2 Slabs 72 Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 73 Granite Work (Full Edge moulding ) 74 P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. 75 size600 mm X 1200mm 76 Providing & fixingBrown Kota/ Mandana / Dholpur/ slate stone incladding / Flooring Structuralbase with white cement & Tinex chemical& SS Clamp and Fasteners (of approved brand) laid and jointed with white cement slurry mixed with pigment to match the shade of the slab as per drawing attachedcomplete in all respect as per direction of Engineer- In- Charge & Architect with all lead & lift. The Stone measurement will be done of outer most dimension. Thickness of stone 25-30mm. 77 Polished Blue Kota stone flooring skirting, laid over 20 mm thick base of C.M. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :For area of each slab from 901 to 2000 Sq.Cm : 78 25 mm thick slab. 79 S/F of fire bricks on edg flooring with fire bricks suitable for 1300 degree centigrade safe working temperature as per IS :8 specification laid on & filling of joint by fire resistant mortar/adhesive of required thickness as per directed on a bed of 20 mm thick 1:2 cement mortar of bricks 9 x 4.5x 3 (Rate approved year 2008) 80 Providing and fixing of glass moisac tiles ( Bisseze Marke ) size 20 x 20 x 4 mm applied with aaproved adhesive as per specification and direction of Engineer in charge 81 Providing and fixing Staincase railing 90 cm high from nosing of made offollowing specifications. 82 50 mm outer dia (2 mm thick) S.S. pipe hand rail. 83 40 mm outer dia (2 mm thick) S.S. pipe baluster @ 1.00 Mtr. 84 4 Nos. 20 mm fS. S pipe intermediate runners parallel to hand. 85 S.S. shoe 1.60 mm thick 75 mm outer dia. At each baluster 86 Baluster to be welded with S.S. plate 50 mm dia (3 mm thick) anchored in C.C. block with suitable dash fastners 87 50 mm dia & 2 mm thick S.S. pipe for start and end vertical ornamental posts to be provided as per direction of Engineer-in-charge 88 The stainless steel work shall be brushed steel finish with all joints/welds properly grinded to final finish. The stainless steel shall be 304 grade and shall confirm to relevant I.S. 89 Providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.Extra if square,rectangular hollow tubularsections are used or grill made by flats only 90 Decorative plaster work with spectrum textured coating as per approved colour and shade complete as per manufactures specifications. 91 Grit Textured @ 2.5 to 3.0 mm thick. 92 Ornamental cement plaster in cement sand mortar1 : 4 making Kangooras etc. as per JaipurPractice. 93 Supplying and fixing machine cutdressed 75 mm Pinksand stone (Bansi Paharpur) dasa/ coping wth ornamental shape having moulding and PAN Shape engraving as per required pattern with engraving depth of 5 mm (average) in single piece of length 90 cm to be laid on cement mortar 1:4 (12 to 20mm thick) including pointing with admixture of pigment matching with the stone shade. 94 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 95 0.63 mm thick with zinc coating not less than 275 gm/m2 96 Supply & Spreading ofgood earth at site complete including loading unloading & transportation etc. 97 Supply of dry manure including loading unloading,transportation & stacking at site. 98 Farm yard manure(organic) 99 Spreading of manure and good earth in required thickness (cost of manure and good earth to be paid separately). 100 Laying of lawns including ploughing levelling breaking of clods manuring & removal of stones etc.(Cost of manure or extra good earth to be paid seperately) Maintenance of lawns for 30 daysor more till the grass forms a thick lawns free from weeds & fit fo 101 In rows 7.5 Cms. apart in either direction 102 Construction of embankment with approved Material obtained from borrow-pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8-10 tonne to meet requirement of Table 300-2 including cost of compensation for earth taken from private land with lead upto 1 km as per MoRTH Specification : Clause No. 305. 103 Rough chisel dressed stone flooring over 20 mm (Av.) thick base in CM 1 : 6 including pointing with cement mortar 1 : 2 (1 cement : 2 stone dust) with and admixture of pigment to match the shade of stone with joint thickness upto 15 mm : 35 mm thick red sand stone. 104 P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark) with P or S trap including cutting and making good the wall and floor 105 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: 106 Size 580x440mm. 107 P & F low level Flushing Cistern of 10 ltr. Capacity (IS : 2556 Mark) o9f approved make with colplete fitting ,C.I. brackets duly painted , brass ball cock with ball, (IS :1703 mark)complete including cutting and making good the wall. 108 WVC with C.P. brass bend. 109 P & F WVC wash basin (1st quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (IS : 8934 Mark) &32 mm C.P. brass waste coupling of approved make, 25 mm G.I. waste pipe complete including cutting & making good the wall.: 110 Size 550 mm x 400 mm dia for counter top 111 1.0 mm thick Salem stainless steel AISI -304 & IS 13983-1994kitchen sink of approved make (Nirali, Neel – kanth, Jaina, Faber-Castell )with large waste coupling. 112 (24 x 18 x 8) (20x16x8) 113 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. 114 C.P. Inlet connection 15mm.Brass (IS : 8931 marked) with 37 cm long pipe and nut. 115 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 116 1000 litres capacity. 117 Providing and fixingSuperior quality (Jaguar Contiental ) CP Brassfittings complete as per direction of EI 118 Bib Cock with long thread 15 mm nominal size 119 Brass / GunmetalHalf-turnwt. 1 Kg.ofapprovedquality / make,25mmnominalbore. 120 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make 121 Gun-metal 32mm nominal bore. 122 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 123 20mm nominal outer dia pipes 124 32mm nominal outer dia pipes 125 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 126 110 mm dia 127 160 mm dia 128 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant: 129 Coupler (socket) 130 110mm dia 131 160 mm dia 132 Plain Tee 133 110mm dia 134 160mm dia 135 Door Tee 136 110mm dia 137 Bend 45 138 110mm dia 139 Vent Cowel 140 110mm dia 141 Door Bend (Left & Right) 142 110mm dia 143 Pipe Clip 144 110mm dia 145 Plain floor trap 146 110mm dia 147 P- Trap 148 110mm dia 149 Socket plug 150 110mm dia 151 Door Cap 152 110mm dia 153 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. 154 -do- size 450 x 450mm depth upto0.5 M Cement cover with frame 155 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked medium duty PVC conduit & its accessories, round tiles,Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch,Modular plate with grid plate,screws,making connections, testing etc. as required. 156 Short point (up to 3 mtr.) 157 Medium point (up to 6 mtr.) 158 Long point(up to 10 mtr..) 159 Wiring of twin control light point with 1.5 Sq.mm FR PVC insulated unsheathed flexiable copper conductor 1.1 KV grade and 1.5 sq.mm.FR PVC insulated unsheathed flexiable copper earth conductor 1.1 KV grade(IS: 694) of approved make in surface/ recessd ISI marked medium duty PVC conduit & its Accessories, round tiles, 18 SWG M.S. box with earthing terminal, 6 Amp two way switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 160 Medium Point (up to 6 Mtr) 161 Wiring of 3 pin 6 Amp light plug point with 1.5 Sq.mm FR PVC insulated unsheathed flexiable copper conductor 1.1 KV grade and 1.5 sq.mm.FR PVC insulated unsheathed flexiable copper conductor 1.1 KV grade(IS: 694) of approved make in surface/ recessd ISI marked medium duty PVC conduit & its Accessories, round tiles, 18 SWG M.S. box with earthing terminal, 6 Amp switch & 6 Amp socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 162 On Board 163 Medium Point (up to 6 Mtr) 164 Long Point (up to 10 Mtr) 165 S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall, covering conduit and making good the same as required. 166 25 mm 167 32 mm 168 50 mm 169 Supplying and fixing of power plug point Modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost ofmodular 16 amp. Switch and socket outlet, making connection , testing , etc. as required. 170 P&F metal clad industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in sheet steel enclosure (without MCB) including making connections, testing etc.as required 171 Single / Double Pole(Three pin) 172 32 A 173 Providing & Fixing ISI marked 6 Amp bakelite batten/angle holder including making connection testing etc. as required. 174 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. 175 2 x 2.5 sq. mm. + 1x1.5sqmm 176 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 177 P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. 178 Single pole MCB 179 6 A to 32 A rating 180 Four pole MCB 181 40 A 63 A rating 182 Four pole MCB 183 6 A to 32 A rating 184 P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DBterminations with copper lugs , testing etc. as required. 185 Double door (single phase) 186 12 Way 187 Double door (Three phase) 188 8 Way 189 P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 190 25.0 Sq.mm 191 4 core 192 50.0 Sq.mm 193 120.0 Sq,mm 194 3.5 core 195 150.0 Sq,mm 196 Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. 197 3.5 x 120.0 sq.mm 198 4 x 25.0 sq.mm 199 P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 200 10.0 Sq.mm 201 4 core 202 Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. 203 4 x 10.0 sq.mm 204 SITC of wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel made out of CRCA sheet , required hardware,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shadeThe panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear. Thickness of sheet shallnot be less than 1.6 mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall beof 2.0 mmthick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / withoutdetachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator) 205 Supplying and fixing of Aluminium / Copper bus barby means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. 206 Electrolytic grade Aluminium bus bar 207 SF of (0-500) V range Volt meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. 208 Analog type ( 96mm x 96mm ) 209 SF of CT operated direct reading typeAmpere meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. 210 Analog type ( 96mm x 96mm ) 211 Below 500 A 212 SF ofCurrent Transformer, with all necessary support in existing panel including connection etc. as required . 213 up to 150/5 Ratio, 10 VA, class 1 accuracy 214 SF of selector switch of 10 A for voltmeter (4 position ) including making connection etc.as required . 215 SF of CT linked selector switch of 10 AforAmpere meter (4 position ) including making connection etc.as required . 216 SF of110/220 V, LED (22.5 mm dia ) Indicatinglamp with integral circuit, terminal block, including connection etc. as required. 217 Red/yellow/Green colour 218 Supplying and drawing FR PVC insulated & unsheathed flexiable copper conductor ISI marked (IS:694) of 1.1 KV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 219 1 x 1.5 sq.mm 220 1 x 2.5 sq.mm 221 1 x 4.0 sq.mm 222 1 x 6.0 sq.mm 223 SITC of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR . including making connections with suitable capacity conductors/cables testing etc. as required. 224 Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) 225 SITC of microprocessor based three phase sensingpower factor correction relay having following sensing capacitysecondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR,metering facility as required. 226 6 to 8 Stage 227 Sensitivity upto 50 milli Amp 228 P & F ofCam operated rotary switchs on existing panel with 2 way and off postion 229 One pole 230 16 Amp 231 P & F of440 Volt 3 pole capacitor(AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. 232 Up to 6 KVAR 233 7 to 10 KVAR 234 P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. 235 Triple pole MCB 236 6 A to 32 A rating 237 P&F on load change over switch, front handle operated, four pole 415 V conforming to IS:13947 P-III including connections , testing etc. as required in the following rating: 238 Open execution Type 239 200 Amp 240 SITC of quick make and quick break4 POLEcurrent limiting MCCB having following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push( test) to trip , including making connections with lugs & spreaders,etc. as required. 241 With Thermal Magnetic release 242 up to 160 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 243 Plate Earthing as per IS:3043 withcopper Earth plate of size 600mm x 600mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 25mm dia. G.I. B class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 244 S & Laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 245 8 SWG copper Wire 246 Providing & fixing of Heavy duty capacitor start 900/1400 RPM single phase ISI marked exhaust Fan IS:2312 marked in existing opening making connections, testing etc. as required 247 300 mm sweep (900/1400 RPM) 248 P & F double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. 249 1400 mm sweep 250 P & F of IP 20 LED tube light 20 watt with external batten made from CRCA sheet steel suitable to replace T-8/T-12 tube light, integral driver, 2000 luman + 5% tolerarrce system luman efficiacy of 100 Lm/ watt minimum expected life time of 25000 burning hours, CCT 5700 K ANSI, CRI 80, driver efficiency >85%, Life expectancy of driver rnin 30000 hrs. PF 0,95 at full load/ 230 volt AC. 251 P & Laying XLPE insulated IS:7098/II/85 of Group1 and approved make H.T.cable for working voltage 11 K.V.Earthed direct in ground including excavation of 30cmx100cm size trench, 25cmlayer of river sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size. 252 3 core 185.0 Sq.mm

Key Value

Document Fees
INR 7500 /-
EMD
INR 800000.0 /-
Tender Value
INR 4 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail