Repair To Summer Appliances (Ceiling Fans, Exhaust Fans Etc) And Repair/ Maint Of Water Coolers, Deep Freezers And Air Conditioners At Mil Stn Patiala And Nabha Under Ge (South) Patiala As Per Tender Documents, patiala-Punjab

Military Engineer Services-MES has published Repair To Summer Appliances (Ceiling Fans, Exhaust Fans Etc) And Repair/ Maint Of Water Coolers, Deep Freezers And Air Conditioners At Mil Stn Patiala And Nabha Under Ge (South) Patiala As Per Tender Documents. Submission Date for this Tender is 09-06-2022. Air Conditioner Tenders in patiala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

32236514
Corrigendum : Repair To Summer Appliances (Ceiling Fans, Exhaust Fans Etc) And Repair/ Maint Of Water Coolers, Deep Freezers And Air Conditioners At Mil Stn Patiala And Nabha Under Ge (South) Patiala As Per Tender Documents
Open Tender
Indian
Punjab
patiala
09-06-2022

Tender Details

Repair To Summer Appliances (Ceiling Fans, Exhaust Fans Etc) And Repair/ Maint Of Water Coolers, Deep Freezers And Air Conditioners At Mil Stn Patiala And Nabha Under Ge (South) Patiala As Per Tender Documents

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Jun-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-06-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repair to summer appliances (Ceiling fans, exhaust fans etc) and Repair/ maint of water coolers, deep freezers and Air Conditioners at Mil Stn Patiala and nabha under GE (South) Patiala.
Sl. No. Item Description
1Dismantling of ceiling fan 1200 /1400 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire ISI marked including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins,body/blade screws and testing on full speed, as per the direction of Engineer-in-Charge complete all as specified and directed .
2All as per item No 1 here- in- before but exhaust fans up to and incl. 230/300 mm sweep.
3All as per serial item No 1 here-in-before butexhaust fans of sweep more than 300 mm and upto 480 mm.
4All as per serial item No 1 here-in-before butwall fansfans of sweep up to 450 mm.
5Replacement of gun metal bush suitable for ceiling fans, exhaust fans and wallfans of any makes/size complete all as specified and directed by Engineer-in-Charge.
6Replacement of ball bearing of suitable for ceiling fans/wall fans/exhaust fans/desert cooler motor of any size/make complete all as specified and directed by Engineer-in-Charge.
7Replacement of capacitor 2.5 mfd, 230 Volts + 5% dry type complete all as specified and directed by Engineer-in-Charge.
8All as per item No 07 here-in-before but 3.15 mfd.
9All as per item No 07 here-in-before but 4 mfd.
10Replacement of rubber reel, nut and bolts, spring washer, split pin for ceiling fans of any Make/Size, complete all as specified and directed by Engineer-in-Charge.
11Taking down ceiling fan /wall fans (any size, make, type) from any position, opening for and including greasing, cleaning, complete overhauling including split pins, body/blade screws , refixing in its original position and testing on full speed complete all as specified and directed incl provn of newcable flexible of copper conductor twin core, PVC insulated of size 23/.0076 ,750 mm long and one run of earth wire and tapping rubber insulating all as directed by Engineer-in-Charge.
12Taking down exhaust fan (any size, make, type) from any position, opening for and including greasing, cleaning, complete overhauling including split pins, body/blade screws , refixing in its original position and testing on full speed complete all as specified and directed incl provn of newcable flexible of copper conductor twin core, PVC insulated of size 23/.0076 ,750 mm long and one run of earth wire and tapping rubber insulating all as directed by Engineer-in-Charge.
13Replacement of ceiling fan blade ( Set of 3) of 1200 mm sweep ceiling fan including nuts, washers etc complete all as specified and directed by Engineer-in-Charge suitable for any make of fan. (white/Browm colour/as per site requirement).
14All as per Serial item No 13 here-in-before but for 1400 mm sweep ceiling fan.
15Turning, grinding and making good seat to ball bearing in proper position ( Ball bearing not included in this item ) complete all as specified and directed by Engineer-in-Charge.
16Supplyand connecting flexible copper wire Cable flexible of copper wire 0.5 sq mm (white colour)complete all as specified and directed by Engineer-in-Charge.
17Supply & fixing as in repair louvers made out of 0.63 mm galvanised iron sheet for Exhaust Fan of any make andsize upto 300 mm complete all as specified and directed by Engineer-in-Charge.
18Supply & fixing as in repair louvers made out of 0.63mm galvanised iron sheet for exhaust fan of any make andsize 380mm/450mmcomplete all as specified and directed by Engineer-in-Charge.
19Replacement ofPVC canopy (upper/bottom) for ceiling fan of any make andsize complete all as specified and directed by Engineer-in-Charge.
20Supply & fixing down rodfor ceiling fans made out of MS pipe 15mm bore medium grade 60 cm long duly threaded, holes drilled and spray painted with synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
21Spray painting on outside body of the ceiling fan incl blades any size with synthetic enamel paint (white colour)including scrapping existing paint and incl writing MES Number with black paint complete all as specified and directed by Engineer-in-Charge.
22Spray painting on outside body of the exhaustfan incl blades any size with synthetic enamel paint(smoke gray colour) including scrapping wxisting paint and incl writing MES Number with black paint complete all as specified and directed by Engineer-in-Charge.
23Taking down desert cooler fixed at any position cleaning internally and externally by scraping all scales dirt etc and repair to desert cooler to stop any typeof leakage, tightening& replacing of screws, nuts and bolts etc all as directed including painting of desert cooler with spray machine with synthetic enamel hammer tone paint over one coat of red oxide primer and refixing of the desert cooler after necessary oiling and greasing of fan and water lifting pump complete all as specified and directed by Engineer-in-Charge.
24Supply and replacement of water lifting pump, 230 volt 50 C/S single phase suitable for desert coolers complete all as specified and directed by Engineer-in-Charge.
25Supplying and replacement wood wool pads of suitable size and providing wire netting of GI wire 1.4 mm dia 25 mm mesh for holding pads complete all as specified and directed by Engineer-in-Charge.
26Supplying and replacement high density polythene pipe 15 mm dia for desert coolers complete all as specified and directed by Engineer-in-Charge.
27Dismantling and taking out old, unserviceable fan motor from the desert cooler andrewinding with supper enamel winding copper wire of suitablesize varnishing etc including replacement of bushes, bearings, washers etc. and assembling testing and refixing in existing position complete all as specified and directed by Engineer-in-Charge.
28Supply and replacement complete steel body of desert cooler of capacity 4000cfm with front grill, side & back panels duly spray painted with synthetic enamel hammer tone paint over one coat of red oxide primer including dismantling and refixing the old parts i.e fan motor, pump etc in new body, replacing the defective wires, PVC pipes and water distributor, making connections and testing complete all as specified and directed by Engineer-in-Charge. The body of desert cooler will be fabricated as under:- (a)The top and bottom made out of 1.25 mm thick GI sheet. (b)Side panels (set of three)made out of 1.00 mm thick GI sheet. (c)Front grill of suitable size and of approved quality.
29Supply & replacementAir direction grill of suitable size with name plate made of iron including fixing to the desert cooler body by means of nut & bolts complete all as specified and directed by Engineer-in-Charge.
30Supply & replacementof ready made PVC copper wire lead of 2 mtr length with 3 pin plug top 5 Amp having Single Phase, Neutral & earth wire of size .75 sqmm including connecting fan motor to regulator/switch complete all as specified and directed by Engineer-in-Charge.
31Supply & replacement of regulator knob type switch, 3 step control of speed of Desert cooler motor 230 volts, 50 Hz complete all as specified and directed by Engineer-in-Charge.
32Supply & replacement of 5 A switch offan motor & water lifting pump 230 volts, 50 Hz complete all as specified and directed by Engineer-in-Charge.
33Supply & replacement of exhaust fan motor holding clamps made out of iron of suitable size complete all as specified and directed by Engineer-in-Charge.
34Supply & replacement of motor holding ring made of metal fixing with nut bolts complete all as specified and directed by Engineer-in-Charge.
35Supply & replacementof side & rear panes (1.0 mm GI sheet) made of iron of suitable size for desert cooler complete all as specified and directed by Engineer-in-Charge.
36Supply & replacementof metal body bottom water storage tank of suitable size (storage cap 40 ltr) for desert cooler duly painted with two coats including fixing/riveting to the existing upper body of desert cooler complete all as specified and directed by Engineer-in-Charge.
37Supply & replacement of Elbow PVCto the existing water PVC pipe complete all as specified and directed by Engineer-in-Charge.
38Supply & replacement of PVC water distributor (three mouth type) including fixing to the body of desert coller complete all as specified and directed by Engineer-in-Charge.
39Supply & replacement PVC Fan Blades of superior quality (having 3 branches) including fixing to the desert cooler motor complete all as specified and directed by Engineer-in-Charge.
40Dismantling and taking out old, unsv exhaust fan motor holding frame, S&F in replacement metal frame suitable for upto 300 mm sweep exhaust fan complete all as specified and directed by Engineer-in-Charge.
41Dismantling and taking out old, unsv exhaust fan motor holding frame, S&F in replacement metal frame suitable for upto 380/400 mm sweep exhaust fan complete all as specified and directed by Engineer-in-Charge.
42Dismantling of fresh air fan of any sweep (any make and type) , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire ISI marked including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins,body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed by Engineer-in-Charge.
43M&L for Servicing of installed Window type Air conditioner of any make 1.5/2.00 TR ton capacity including taking down , dismantling from grill , taking out air conditioner, removing all electrical components, cleaning the AC coils & fin using bubble method by applying chemical solution,cleaning with brush, washing with pressure water, oiling/greecing moving parts and reassembling complete all as specified and directed by Engineer-in-Charge. Note :- Various check to be doneduring servicing of Window type Ac 1.5/2.0 TR and spares/items required for replacement of unsv spare/item will be measured under relavant items.
44M&L for Servicing of installed SplitAir conditioner of any make 1.5/2.0 TR capacity indoor and out door units including taking down , dismantling from grill , taking out air conditioner , removing all electrical components, cleaning with brush , condenser, washing with presure water , oiling moving parts and reassembling complete all as specified and directed by Engineer-in-Charge. Note :- Various check to be doneduring servicing of Split type Ac 1.5/2.0 TR and spares/items required for replacement of unsv spare/item will be measured under relavant items.
45Carrying out gas leakage check and rectifrying /arresting the same by brazing and recharging refrigerant gas, comissioning and testingto entire satisfaction of Engr-in-charge for 1.5/2.0 TR capaity Window/ Split AC complete all as specified and directed by Engineer-in-Charge.Note :- Gas wiil be measured under relevant item.
46Recharging of Refrigerant Gas F-22 complete including testing of leakage and testing the AC unit of any capacity and typefor satisfactory performance complete all as directed by Engineer-in-Charge.
47Supply and replacement of defective front grill decorative suitable forwindow type AC"s 1.5/2.00 ton capacity of any make mentioned hereinafter as per the original/existing model of air conditioner complete all as specified and directed by Engineer-in-Charge.
48Supply and replacement of operating knobsof window type AC"s of any make of make and modelas per the existing model/size complete all as specified and directed by Engineer-in-Charge.
49Supply and replacement of selector switch on / off having five stepping for window type AC 1.5 /2 ton capacity complete all as specified and directed by Engineer-in-Charge.
50Supplying and replacement of air filter as per original sample complete all as specified for AC"s 1.5/2.0 Ton of any type/any make complete all as specified and directed by Engineer-in-Charge.
51Taking downunserviceable Air Conditioner cap. 1.5/2.0 ton from any posn. and removing unserviceable burnt sealed unit (compressor) from AC and S & Fixnew compressor unit and testing on required pressure and installing at its original posn. complete all as specified and directed by Engineer-in-Charge. Note : Cost offilling with refrigerant gas is included in unit rate of this item.
52Disconnecting & Taking downunserviceable Automatic Voltage Stabilizer 4/5 KVA rating (provided for AC only.Checking & Reair of Operating Relays, Timer Relay, Relay Coil & its coneections, PCB Circuit Board, Rectifier circuit, Copmarators, Switching Circuit, Transformer, high/low voltage output fault.Installing at its original position after repair and testing complete all as specified and directed by Engineer-in-Charge. Note :- Major Items for repair will be measured under relavant items.
53Supply in replacement of set of Relay 04P. Relay 25 Amp - Qty 04 Nos & 01P. Relay 25 Amp(12volts)-Qty 01 No. complete all as specified and directed by Engineer-in-Charge.
54Supply in replacement of Timer relay for 1.5/2.0 TR AC complete all as specified and directed by Engineer-in-Charge.
55Supply in replacement of Auto Swing Synchronous Motor having 5-6 rpm, 230 Volts, 50 Hz, 3 W suitable for 1.5/2.0 TR AC complete all as specified and directed by Engineer-in-Charge.
56Supply in replacement of Blower/Condensor Fan PVC body matching to existing blower, suitable for window typeAC 1.5/2.0 TR complete all as specified and directed by Engineer-in-Charge.
57Supply in replacement of Blower/Condensor Fan 708/102 mm PVC body matching to existing blower, suitable for Split type AC 1.5/2.0 TR complete all as specified and directed by Engineer-in-Charge.
58Supply in replacement of Capacitor AC 40-45 mfd matching to existing rating capacitor, suitable for compressor of window AC 1.5/2.0 TR complete all as specified and directed by Engineer-in-Charge.
59M&L for checking of unsv PCB board of window/Split type AC 1.5/2.0 TR for cleaning of PCB by applying cleaning solution, testing of circuits, replacement of transistor/IC"s, soldering work, AC to DC converter etc. and assembling the same after testing and working satsfactory complete all as specified and directed by Engr-in-Charge.
60Supply in replacement of remote of original company suitable to existing one or match to Split/Window AC,complete all as specified and directed by Engr-in-Charge.
61M&L for Servicing of installed Water Cooler of capacity 40/40, 40/80 &150 Ltr of any make including taking down, dismantling from any position, disconnecting all electricl/water connections, testing of compressor functionability, testing for gas leakage/arrest of leakage, pressure of refrigerant, testing of Fan Motor, checking of flexible drain pipe, water inlet/outlet PVC pipe,checking of float valve, checking of Thermostate, operating knobs & Copper Capillary tubes, Cleaning of Cooling Coils & Fin using Bubble method by applying chemical solution,cleaning with brush, washing with pressure water, oiling/ greecing of moving parts and reassembling the same complete all as specified and directed by Engr-in-Charge. Note :- Various check to be done during servicing of Water Cooler any type any capacity and spares/items required for replacement of unsv spare/item will be measured under relavant items.
62Taking down unserviceable water cooler 40/80 litre cap from any posn and removing unserviceable burnt sealed unit ( compressor ) from water cooler and Supply & Fixnew compressor unit and testing on required pressure and installing cooler at its original posn. complete all as specified and directed by Engr-in-Charge. Note : Cost offilling with refrigerant gas is included in unit rate of this item
63Taking downunserviceable water cooler 120/150 litre cap. from any posn. and removing unserviceable burnt sealed unit ( compressor ) from cooler and S & Fnew compressor unit and testing on required pressure and installing cooler at its original posn. complete all as specified and directed by Engr-in-Charge. Note : Cost offilling with refrigerant gas is included in unit rate of this item.
64Supply & replacement ofthermostat switch suitable for water coolers including knobs, plate and screws for40/80/120/150 ltr capacity complete all as specified and directed by Engr-in-Charge.
65Supply and replacement Running Capacitor suitable for water cooler 40/80/150 ltr capacity complete all as specified and directed by Engr-in-Charge.
66Supply & replacement ofstarting relay assembly including replacement of cover and clips suitable for water coolers of capacity 120/150 ltr complete all as specified and directed by Engr-in-Charge.
67Supply & replacement ofstarting relay assembly including replacement of cover and clips suitable for water coolers of capacity 40/80 ltr complete all as specified and directed by Engr-in-Charge.
68Supplying and replacement of Over Load Protection Relay for Water cooler 120/150litre cap. complete all as specified and directed by Engr-in-Charge.
69Supplying and replacement of Over Load Protection Relay for Water cooler 40/ 80 litre cap. complete all as specified and directed by Engr-in-Charge.
70Supplying and replacement of Starting Capacitor for Water Cooler 120/150 litre cap. complete all as specified and directed by Engr-in-Charge.
71Supplying and replacement of Starting Capacitor for Water Cooler 40/80 litre cap. complete all as specified and directed by Engr-in-Charge.
72Taking down unserviceable Fan Motor of Water Cooler of 150 litres capacity and rewinding with suitable size of super enamelled copper winding wire including replacement of bushes, rubber mounting , clips and commissioning and testing complete all as specified and directed by Engr-in-Charge.
73Taking down unserviceable fan motor of water cooler of 40/80 ltr capacity and rewinding with suitable size of super enamelled copper winding wire including replacement of bushes, rubber mounting, clips and commissioning and testing complete all as specified and directed by Engr-in-Charge.
74Taking down old unserviceable Fan Motor & S&F new Fan Motor suitable for water cooler ofcap 40/80 ltrs capacity complete all as specified and directed by Engr-in-Charge.
75Taking down old unserviceableFan Motor of Water Cooler 150 Ltr.S&F new fan motor suitable for the same Water Cooler complete all as specified and directed by Engr-in-Charge. NOTE : All items retrieved from this sec of sch. shall be property of contractor and contractor shall lafford credit for this account as per sch of credit.
76Supply and replacement stainless steel water tap 15 mm dia, pressing type, self releasing, chromium plated push cock heavy duty (as per existing) complete all as specified and directed by Engr-in-Charge.
77Cleaning of water cooler body of capacity 40/40, 40/80/150 ltrs internally and externally including scraping and removing all scales and dirt etc. Repair to body to stop leakage and replacing unserviceable screws, nut & bolts etc. spraypainting of water cooler withsynthetic enamel paint hammer tone paint including prepairation of surfaces and applying red oxide primer complete all as specified and directed by Engr-in-Charge.
78Supplying and replacement PVC flexible copper cable 3 core 40/0.0076 length complete all as specified and directed by Engr-in-Charge.
79Recharging of Refrigerant Gas F-22 complete including testing of leakage and testing the Compressor of Water Cooler of any capacity and typefor satisfactory performance complete all as directed by Engineer-in-Charge.
80supply in replacement of Stailless Steel Basin Tray of water Cooler 40/80/150 Ltr.complete all as specified and directed by Engr-in-Charge.
81Supply in replacement of Drain pipe flexible of size 1.5 inches long upto 1.5 mtr suitable for 40/80/150 Ltr capacity water cooler complete all as specified and directed by Engr-in-Charge.
82Supply in replacement of Water Inlet PVC pipe of 15 mm size including connecting to the water supply point to water cooler storage tank inlet point & ensure for no leakage of water from both points, suitable for 40/80/150 Ltr capacity water cooler complete all as specified and directed by Engr-in-Charge.
83Supply in replacement of Float Ball & Valve Assembely matching to the existing unsv float Ball & Assembely including fixing suitable for 40/80/150 Ltr capacity water cooler complete all as specified and directed by Engr-in-Charge.
84Supply in replacement of Copper Capilary tube of dia 0.026 mm upto 8 to 10 feet length including High/Low Pressure convertor device, matching to the existing unsv device & capilary tubes including fixing suitable for 40/80/150 Ltr capacity water cooler complete all as specified and directed by Engr-in-Charge.
85M&L for Servicing of installed Refrigerator 180/200/250/280/300/310/315 Ltr capacity and Deep Freezer of capacity 320 Ltr of any make including taking down, dismantling from site, disconnecting all electricl connections, testing of compressor for functionability, pressure of refrigerant, checking of Thermostate, operating buttons, testing of PCB Board & Copper Capillary tubes, Cleaning of Condensor Coils from inner sideusing Bubble method by applying chemical solution,cleaning with brush, washing with pressure water, oiling/greecing of moving parts icludingprovinding minor nut/screws et.c and reassembling the same complete all as specified and directed by Engr-in-Charge. Note :- Various check to be done during servicing of Refrigerator & Deep Freezer any type any capacity and spares/items required for replacement being unsv will be measured under relavant items.
86Taking down unserviceable Refrigerator 300/310/315 Ltr capacity from the site and transporting to workshop for repair, removing unserviceable burnt sealed unit (compressor) fromthe refrigerator and supply & fix new compressor including testing on required pressure and transporting back to its site and fix in original position complete all as directed by Engr-in-Charge.
87Taking down unserviceable Refrigerator 180/200/250/280 Ltr capacity from the site and transporting to workshop for repair ,removing unserviceable burnt sealed unit (compressor) fromthe refrigerator and supply & fix new compressor including testing on required pressure and transporting back to its site and fix in original position complete all as directed by Engr-in-Charge.
88Taking down unserviceable Deep Freezer300/320 Ltr capacity from the site and transporting to workshop for repair ,removing unserviceable burnt sealed unit (compressor) fromthe refrigerator and supply & fix new compressor including testing on required pressure and transporting back to its site and fix in original position complete all as directed by Engr-in-Charge.
89Recharging of Refrigerant Gas R-134A complete including testing of leakage and testing the Compressor of Refrigerator/Deep freezer of any capacity and typefor satisfactory performance complete all as directed by Engineer-in-Charge.
90Supply in replacement of Copper Capilary tube of dia 0.031 mm having lenth upto 8 to 10 feet including High/Low Pressure convertor device, matching to the existing unsv device including fixing of the same suitable for 310/315/320 Ltr capacity Refrigerator/Deep Freezer complete all as specified and directed by Engr-in-Charge.
91Supply & Fixing as inrepairs of Refrigerator door (plastic) complete with tension spring as per original complete all as directed by Engr-in-Charge.
92Supply & Fixing as in repairs of 320 Ltr acpacity Deep Freezer door (Plastic) complete with tension spring as per original complete all as directed by Engr-in-Charge.
93Supply & Fixing as in repairslce Tray plastic as per original complete all as specified and directed by Engr-in-Charge.
94Supply &Fixing as in repairsfruit/ vegitable Tray as per original complete all as specified and directed by Engr-in-Charge.
95Supply & Fixing as in repairsfruit/vagitable Glass cover complete as per original complete all as specified and directed by Engr-in-Charge..
96Supply and replacement of pigmy Lamps (bulb) of refrigerator complete as per existing complete all as specified and directed by Engr-in-Charge.
97Supply & Fixing as in repairsRefrigerator door seal (gasket)/flexible elastic strip attached to the outer edge of refrigerator or freezer compartment in the Refrigerator/Deep Freezer of cap 180/310/315/320 Ltr.complete all as specified and directed by Engr-in-Charge.
98Supply & Fixing as in repairsdoor megmetic gasket complete as per original make for refrigerator 300/310 ltr capacity complete all as directed by Engr-in-Charge.
99Supplying and replacement Relay Box type for 310/315 Ltr capacity refrigerator complete all as specified and directed by Engr-in-Charge.
100Supplying and replacement of Over Load Protector Single Phase 230 Volts, 50 Hzsuitable for Refrigerator/Deep Freezer 180/300/310/315 Ltr capacity complete all as directed by Engr-in-Charge.
101Supplying and replacement of door lock with two keys as per original specification for Refrigerator 180/310/315 Ltr complete all as directed by Engr-in-Charge.
102Supplying and replacement of drian water Collector container made of PVC suitable for Refrigerator 180/300/310/315 Ltr Capacity complete all as directed by Engr-in-Charge.
103Supplying and replacement of Copper Filter Drier in Refrigerator 180/310/315 Ltr capacity complete all as directed by Engr-in-Charge.
104Disconnecting & Taking downunserviceable Automatic Voltage Stabilizer upto 2 KVA rating connected to Refrigerator/Deep Freezer/Water Coolers.Carry out repair to Operating Relays, Timer Relay, Relay Coil & its connections, PCB Circuit Board, Rectifier circuit, Copmarators, Switching Circuit, Soldering work, Transformer, high/low voltage output fault.Installing at its original position after repair and testing all as specified and directed. Note :-Cost of spares/parts required to be replacement will be included in quoted rate.
105Supplying and replacement of voltmeter of range 0-500 volts single phase 230/240 volts, 50 Hz suitable for Refrigerator/Deep Frizeer 180/310/315 Ltr capacity complete all as directed by Engr-in-Charge.
106Supplying and replacement PVC flexible copper cable 3 core 40/0.0076 length suitable for 50 Hz, 240 volts equipments alongwith Indian type 3 pin Plug top duly compacted with copper cable for Refrigerators/Deep Freezers/Water coolers complete all as specified and directed by Engr-in-Charge.
107Supplying and replacement of Indian Thermostate for single door/double door Refigerator 180/310/315 Ltr/Deep Freezer 320 Ltr as per existing rating of thermostate compatible for Voltas/Samsung/Usha/Blue Star/Kelvinator/Godrej/Whirlpool complete all as directed by Engr-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy