Military Engineer Services-MES has published Comprehensive Repair To Flooring , Boundary Walls , Path And Periodical Services Under Ge Nagrota.. Submission Date for this Tender is 02-06-2022. Flooring Work Tenders in nagrota Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Taking down cement plaster on brick or stone walls, etc .including raking out joints, hacking for key, scrubing down with water etc . |
2 | M & L 15mm thick rendering onbrick work or concrete surface in cm 1:4 to be fair and even with out using extra cement. NOTE:-PLASTER SHALL BE DONE AT ANY HEIGHT.RATES ARE INCLUDING SCAFFOLDING . |
3 | M & L preparation of new decorated surfaces of external walls and applying two coat of PREMIUM QUALITY OF cement base paint over a coat of primer complete as specified and directed. MAKE:-ASIAN,NEROLAC (FIRST QUALITY) NOTE:-1.SHADE SHALL BE APPROVED BY GE. 2.NO EXTRA PAYMENT SHALL BE MADE IF EXTRA COAT WILL BE REQUIRED TO MATCH APPROVED SHADE. |
4 | M&L for preparing old plastered surfaces of wall and applying one coat of PREMIUM QUALITYcement based paint all as specified . MAKE:-ASIAN,NEROLAC (FIRST QUALITY) NOTE:-1.SHADE SHALL BE APPROVED BY GE. 2.NO EXTRA PAYMENT SHALL BE MADE IF EXTRA COAT WILL BE REQUIRED TO MATCH APPROVED SHADE. |
5 | M&L for preparing old plastered surfaces of wall and applying Two coat of cement based paint all as specified . MAKE:-ASIAN,NEROLAC (FIRST QUALITY) NOTE:-1.SHADE SHALL BE APPROVED BY GE. 2.NO EXTRA PAYMENT SHALL BE MADE IF EXTRA COAT WILL BE REQUIRED TO MATCH APPROVED SHADE. |
6 | M&L for preparation of new/old plastered wall surface and applying two coats of exterior emulsion paint (Comoflized pattern) Over a Coat ofWall Care Putty1-2 MmAll Complete all as specified and directed. NOTE:-1.SHADE SHALL BE APPROVED BY GE. 2.NO EXTRA PAYMENT SHALL BE MADE IF EXTRA COAT WILL BE REQUIRED TO MATCH APPROVED SHADE. |
7 | M&L for preparation of new/old plastered wall surface and applying two coats of exterior emulsion paint Over a Coat ofWall Care Putty 2 MMAll Complete all as specified and directed. |
8 | Preparation of old painted steel surfacesof any description not otherwise described over 10cm width or girth, and applying one coat of synthetic enamel paint complete all as specified. |
9 | Demolition of brick work or stone masonry, built in CM including all quoins, arches, pillars etc. but excluding ashlar facing, dressed stone work and precast concrete articles. |
10 | Brick work with sub class B (old size) brick straight or curved on plan exc 6 mmean radius in CM 1:4 complete all as specified. |
11 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for like MH cover, bdrain pipe bed, hard standing etc complete all as specified. |
12 | M&LPcc type 1:3:6 (40 mm graded aggregate ) as in surface channel and drains |
13 | M & L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends, complete all as specified and directed. |
14 | M & L PCC ,Type B-0,1:2:4 (using 12.5 mm graded aggregate) as in plinth courses,kneelers, coping, etc. water troughs and the like including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. |
15 | M&L walling of RR masoanry, uncooursed, well bonded, bedded and solidly hearted built in CM 1:6. |
16 | Ditto-of item No abovebutexcept stone . |
17 | Extra over stone walling for hammer dressing to face stones and dressing of face stones and dressing of face beds and joints , as specified , of random rubble walling , uncoursed or brought upto courses, hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40 mm, Lime or Sand stone, all as specified . |
18 | Raised pointing to Random rubble masonry, uncoursedor brought upto course in CM 1:4. |
19 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for like MH cover, bdrain pipe bed, hard standing etc complete all as specified. |
20 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
21 | M/L 100 mm thick Cement concrete type B2, 1:2:4 (using 40 mm graded granite stone aggregate) in base of flooring/ hard standing finished evern & smooth w/o using extra cement.. |
22 | M/L 75 mm thick Cement concrete type B2, 1:2:4 (using20mm graded granite stone aggregate) in base of flooring/ hard standing finished evern & smooth w/o using extra cement.. |
23 | S & F Factory made 18 mm thick celuka PVC ply of density 600kg/cbm for KICTHEN CABINETS and drawers including all Hettic fittings like Hydraulic channels,slowmotion hinges,Hydraulic shockers and 300 mm stainless steel handles as per site reqirements and manufacturer test certificate is required at the time of PAYMENT. MAKE:- RAJSHRI PLASTIWOOD,ECOCEL BY ECHON. NOTE:-1. WORK SHALL BE EXECUTED BY COMPANY REPRESENTIVES ONLY WITH GUARANTEE CERTIFICATE. 2.PVC ADHESIVE SHALL BE USED FOR PASTING THE PLY APPROVED BY MANUFACTURER 3. ONLY FRONT ELEVATION SHALL BE CONSIDERED FOR MEASUREMENT PURPOSE |
24 | M & L 75mm thick PCC1:3:6Type B2 ( 40 mm graded aggregsate) as in subbase and pavings etc all as specified. |
25 | M&L for Sand filling under floors or in foundations including watering and consolidation all as specified and as directed |
26 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100 mm thickness., M-40 Grade etc all as specified. NOTE:- 1. INTERLOCK PAVER SHALL BE MADE OF 100% WHITE CEMENT AND TESTING SHALL BE DONE BY IIT JAMMU OR APPROVED TEST LABS BEFORE COMMENCEMENT OF WORK. 2. COMPRESSIVE STRENGTH OF INTERLOCK PAVER SHALL BE FULLY CHECKED BEFORE COMMENCEMENT OF WORK. 3.SAMPLE HAS BEEN KEPT IN GE OFFICE. |
27 | M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thicknessM-40 Grade etc all as specified NOTE:- 1. INTERLOCK PAVER SHALL BE MADE OF 100% WHITE CEMENT AND TESTING SHALL BE DONE BY IIT JAMMU OR APPROVED TEST LABS BEFORE COMMENCEMENT OF WORK. 2. COMPRESSIVE STRENGTH OF INTERLOCK PAVER SHALL BE FULLY CHECKED BEFORE COMMENCEMENT OF WORK. 3.SAMPLE HAS BEEN KEPT IN GE OFFICE. |
28 | M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thicknessM-40 Grade etc all as specified NOTE:- 1. INTERLOCK PAVER SHALL BE MADE OF 100% WHITE CEMENT AND TESTING SHALL BE DONE BY IIT JAMMU OR APPROVED TEST LABS BEFORE COMMENCEMENT OF WORK. 2. COMPRESSIVE STRENGTH OF INTERLOCK PAVER SHALL BE FULLY CHECKED BEFORE COMMENCEMENT OF WORK. 3.SAMPLE HAS BEEN KEPT IN GE OFFICE. |