Development Of Distribution Infrastructure Of Package Mirzapur At Mirzapur, Sonbhadra And Sant Ravidas Nagar District Of Puvvnluttar Pradeshunderrevamped Reforms-Based And Results-Linked, Distribution Sector Scheme- 1 Supply Of Consumer Service Cab, mirzapur-Uttar Pradesh

Purvanchal Vidyut Vitaran Nigam Limited has published Development Of Distribution Infrastructure Of Package Mirzapur At Mirzapur, Sonbhadra And Sant Ravidas Nagar District Of Puvvnluttar Pradeshunderrevamped Reforms-Based And Results-Linked, Distribution Sector Scheme- 1 Supply Of Consumer Service Cab. Submission Date for this Tender is 03-06-2022. Crushers Breakers and Grinders Tenders in mirzapur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32208463
Corrigendum : Development Of Distribution Infrastructure Of Package Mirzapur At Mirzapur, Sonbhadra And Sant Ravidas Nagar District Of Puvvnluttar Pradeshunderrevamped Reforms-Based And Results-Linked, Distribution Sector Scheme- 1 Supply Of Consumer Service Cab
Open Tender
Indian
Uttar Pradesh
mirzapur
03-06-2022

Tender Details

Development Of Distribution Infrastructure Of Package Mirzapur At Mirzapur, Sonbhadra And Sant Ravidas Nagar District Of Puvvnluttar Pradeshunderrevamped Reforms-Based And Results-Linked, Distribution Sector Scheme- 1 Supply Of Consumer Service Cable 2 Supply Of Armored Service Cable For Consumer Service Connection With Accessories As Per Technical Specifications, Scope Of Works And Approved Drawings 3 Supply Of Single Phase Armored Al Cable Size 2Cx 6 Sq Mm 4 Supply Of Three Phase Armored Al Cable Size 4Cx 16 Sq Mm 5 Supply Of 10 Swg Gi Wire 6 Supply Of 8 Swg Gi Wire 7 Conversion Of Existing Lt Lines On Bare Conductor To Areal Bunch Xlpe Cable 8 Conversion Of Existing Lt Lines With Bare Conductor To Ab Xlpe Cable Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 9 Supply Of 8.5 M / 180 Kgs Pcc Poles ( Pcc Pole As Per State Practice ) 10 Galvanized Stay Set For Lt Line With Anchor Plate ( 200X200x6mm ) , 50X8mm Stay Clamp, Stay Guy Insulator, Nut Bolts, 1 Nos Turn Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 11 Conversion Of Existing Lt Lines Using New Earthing As Per Approved Drawings, Technical Specifications And Scope Of Work 12 Supply Of Spike Earthing Made Of 20Mm X 2500 Mm Gi Solid Rod 13 Supply Of 8 Swg Gi Wire For Earthing And Guarding 14 Supply Of Following Lt Ab Xlpe Cable For Conversion Of Existing Lt Bare Conductor Line With Ab Xlpe Cable As Required As Per Technical Specification, Approved Drawings And Scope Of Work: 15 Supply Of Aerial Bunchedxlpe Cable 3 X 50 Sqmm+1X35 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 16 Supply Of Aerial Bunchedxlpe Cable 3 X 70 Sqmm.+1X50 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 17 Supply Of Aerial Bunchedxlpe Cable 3 X 95 Sqmm.+1X70 Sqmm. ( Bare Messenger Wire ) + 1X16 Sqmm. 18 Supply Of Aerial Bunchedxlpe Cable 3 X 120 Sqmm. + 1X95 Sqmm. ( Bare Messenger Wire ) +1X16 Sqmm. 19 Supply Of Pole Mounted Lt Distribution Box As Per Approved Drawings, Technical Specifications And Scope Of Work 20 Supply Of Three Phase Smc Distribution Box With Clamps 21 Supply Of Single Phase Smc Distribution Box With Clamps 22 Supply Of Xlpe Insulated Al. Cable For Energisation Of Distribution Box / Kiosk As Per Approved Drawings, Technical Specifications And Scope Of Work 23 Supply Of 1X25 Mm2 Xlpe Insulated Al.Cable 24 Supply Of Stone Pad ( 300X300x75 ) 25 Supply Of Accessories For Ab Xlpe Cable As Per Approved Drawings, Technical Specifications And Scope Of Work 26 Stainless Steel Strap 27 Hdg Lt Pole Clamp With Nut & Bolt For Laying Abc 28 Dead End Clamp With I-Hook ( Insulated ) 29 Suspension Clamp With I-Hook ( Insulated ) 30 95 / 35 Sqmm - 70 / 25 Sqmm Pg Clamps ( For Line To Line Jumpering & Energizing Db Neutral ) 31 120 / 50 Sqmm - 95 / 25 Sqmm Pg Clamps ( For Line To Line Jumpering & Energizing Db Neutral ) 32 Lt Insulation Piercing Connector 120-50 Sqmm - 50-25 Sqmm Size ( For Energizing Distribution Box ) 33 Lt Insulation Piercing Connector 120-50 Sqmm - 120-50 Sqmm Size ( For Line To Line Jumpering ) 34 Lt Insulation Piercing Connector 16 - 25Sqmmsize Suitable For Street Light Connection 35 Pre-Insulated Compression Connectors Size 16 Sqmm Suitable For Ab Xlpe Cable 36 Pre-Insulated Compression Connectors Size 50 Sqmm Suitable For Ab Xlpe Cable 37 Pre-Insulated Compression Connectors Size 70 Sqmm Suitable For Ab Xlpe Cable 38 Pre-Insulated Compression Connectors Size 95 Sqmm Suitable For Ab Xlpe Cable 39 Pre-Insulated Compression Connectors Size 120 Sqmm Suitable For Ab Xlpe Cable 40 Heat Shrinkable Type End Cap For Ab Xlpe Cable 41 Supply Of New 11 Kv Lines : Feeder Segregation ( Agriculture Feeder ) 42 Supply Of Support For 11 Kv Overhead Line As Per Technical Specification, Approved Drawings And Scope Of Work 43 Supply Of 8.5M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 44 Supply Of 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 45 Supply For 3 Phase 11 Kv Line Using New Pre-Fabricated Hot Dip Galvanized Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Ms Angle, Ms Transformer Base Channel, Ms Flats Pole Extension Canal With Welded Plate, Anti Climbing Device Clamp Etc Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 46 Supply Of Hot Dip Galvanized Ms Nuts, Bolts With Washers And Turn Buckle For Guarding Etc. As Per Technical Specification, Approved Drawings And Scope Of Work. 47 Supply Of Pole Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 48 Supply Of 11 Kv Danger Board 49 Supply Of Stone Pad 300X300x75 50 Supply Of Barbed Gi Wire 12 Swg 51 Supply Of Stay Set ( Galvanized ) With 50X8 Mm Stay Clamp, Stay Insulator ( 1 Nos. ) , Anchor Plate ( 200X200x6 ) , Nut Bolts, 1 Nos Turn-Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. 52 Supply Of Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work. 53 Supply Of 11 Kv45 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 54 Supply Of 11 Kv 5 Kn Polymer Pin Insulators 55 Supply Of Earthing Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 56 Supply Of Spike Earthing 20Mm X 2500 Mm Solid Rod 57 Chemicalrod Earthing Including Electrode, Chemical, With 2000Mm Long, 50 Mm Diametergi Pipe, Gi Strip Of 24X3mm Minimum In Hard Rock Locations Only. 58 Supply Of 8 Swg Gi Wire For Earthing And Guarding 59 Supply Of 6 Swg Gi Wire For Earthing And Guarding 60 Supply Of Acsr Conductors Of Following Sizes With Jointing Sleeves, Binding Materials, Pg Clamps, Bi-Metallic Clamp, Hardware Etc For Overhead Line And Jumpers As Required As Per Technical Specification, Approved Drawings And Scope Of Work 61 Supply Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel 62 Supply Of 11 Kv, 600A, 3-Ph, 3 Pin Type, Vertical Mounting Type, Gang Operated, Ab Switch Along With Support Insulators, Base Channel Down Pipe, Arcing Horns Etc. Complete Asper Technical Specifications, Scope Of Works And Approved Drawings 63 Supply Of 11 Kv Lineunderground Railway Crossing Ensuring Statutory Clearances As Required As Per Technical Specification, Approved Drawings And Scope Of Work 64 Supply For 11 Kv Lineunder Ground Railway Crossing With 2 Nos ( Including One Spare ) 3Cx185 Sqmm Xlpe Armored Cable ( 0.3 Km Each ) Using 150Mm Dia Gi Pipes ( Grade A For Underground Laying And Grade B For Pole Support ) , Outdoor Heat Shrinkable Cable Jointing Kit, 11 Kv Lightening Arrestor Station Class 10Ka ( 6 Nos. ) , Lugs, 4 Nos Gi 3-Meters Long Pipe Earthing, 6 Swg Gi Wires, Cable Markers, Bi Metallick Clamps And Jumpering Etc As Required As Per Technical Specifications, Drawings And Scope Of The Work. 65 Supply Of 11 Lv Line Underground Highway Crossing Ensuring Statutory Clearancesas Required As Per Technical Specification, Approved Drawings And Scope Of Work 66 Supply Of 11 Kv Lineforunder Ground Highway Crossing By 2 Nos ( Including One Spare ) 3Cx185 Sqmm Xlpe Armored Cable ( 0.3 Km Each ) Using 160 Mm Hdpe Pipe At Road Crossing And 150Mm Dia Gi Pipes ( Gradeb For Pole Support ) , Outdoor Heat Shrinkable Cable Jointing Kits, 11 Kv Lightening Arrestor Station Class 10Ka ( 6 Nos. ) , Lugs, 4 Nos Gi 3-Meters Long Pipe Earthing, 6 Swg Gi Wires, Cable Markers, Bi Metallick Clamps And Jumpering Etc As Required As Per Technical Specifications, Drawings And Scope Of The Work. 67 Supply Of 12 Kv 3Ph Indoor Type Switch Gear And 11 Kv Xlpe Cable As Per Technical Specifications, Approved Drawings And Scope Of Works: 68 Supply Of Indoor Type 12 Kv 3 Ph 1250 A Vcb With Control And Protection System For Out Going Feeder Consisting Ofct, A-Meter, Volt-Meter, Relays, Energy Meter ( Tvm ) Dlms Compliant & Accessories Complete As Per Specifications For Feeder Breaker Protection 69 11 Kv 3X 185 Sqmm Xlpe Armored Power Cable, Aluminum Stranded Conductor, Including Their Termination Materials Like Indoor And Outdoor Termination Kit, Glands, Lugs, Tagging, Cable Path Marker Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of The Works. 70 Supply For Augmentation Of Lines 71 Supply For Augmentation Of 33 Kv Line 72 Supply For Augmentation Of 3 Phase 33 Kv Line Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 73 Supply Of 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 74 Supply New Pre-Fabricated Hot Dip Galvanized Steel Item, For Augmentation Of 33 Kv Line, Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Ms Angle ( 65X65x6mm ) , Ms Flats ( 65X8mm ) Anti Climbing Device Clamp Etc Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 75 Supply Of Hot Dip Galvanized Ms Nuts, Bolts With Washers And Turn Buckle Etc. As Per Technical Specification, Approved Drawings And Scope Of Work. 76 Supply Of Pole Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 77 Supply Of 33 Kv Danger Board 78 Supply Of Gi Barbed Wire 12 Swg 79 Supply For Augmentation Of 3 Phase 33 Kv Line Replacing Existing Conductor With Following Type Of New Acsr Conductor Including Jointing Sleeves, Binding Material, Aluminum Tape And Helical Preformed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 80 Supply Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog Replacing Existing Racoon Conductor 81 Supply Of 30 / 3.00 + 7 / 3.00 Mm ( 200 Mm² Al. Area ) - Panther Replacing Existing Dog / Racoon Conductor 82 Supply Of 33 Kv Under Ground Cable As Per Technical Specification, Approved Drawings And Scope Of Work. 83 Supply Of 3Cx300 Sqmm 33 Kv Xlpe Armored Cable 84 Supply Of Accessories For 33 Kv3cx300 Sqmm Xlpe Armored Cable ( 2 Nos Including One Spare ) , Like 160Mm Dia Hdpe Pipes For Road Crossing And 150 Mm Dia Gi Pipegrade B For Pole Support Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, Cablepath Markers, Bi Metallic Clamps And 7 / 20 Gi Wire As Per Technical Specification, Approved Drawing And Scope Of Work 85 Supplyof New Insulator And Hardware For Augmentation Of33 Kv Line As Per Technical Specification, Approved Drawings And Scope Of Work 86 Supply Of 33 Kv 70 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 87 Supply Of 33 Kv 10 Kn Polymer Pin Insulators 88 Supply Of New Earthing Arrangement For Augmentation Of33 Kv Line As Per Technical Specifications, Approved Drawings And Scope Of Work. 89 8 Swg Gi Coil 115 Turns ( 1.85 Kg ) 90 Chemicalrod Earthing Including Electrode, Chemical, With 2000Mm Long, 50 Mm Diametergi Pipe, Gi Strip Of 24X3mm Minimum In Hard Rock Locations Only. 91 Supply Of New Stay Set ( Galvanized ) For 33 Kv Line With 50X8 Mm Stay Clamp, Guy Insulator, Anchor Plate ( 300X300x8mm ) , Nut Bolts, Turn-Buckles, 1.8 M Long, 20 Mm Diameter Solid Gs Stay Rod & 7 / 4.00 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. 92 Supply Of New Gi Wire For Earthing And Guarding For Augmentation Of33 Kv Line As Per Technical Specification, Approved Drawings And Scope Of Work. 93 Supply Of 6 Swg Gi Wire 94 Supply Of 8 Swg Gi Wire 95 Supply Of Conductor Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 96 Supply Of Pg Clamp For Dog To Dog Conductor 97 Supply Of Pg Clamp For Panther To Panther Conductor 98 Supply For Augmentation Of 11 Kv Lines 99 Supply For Augmentation Of 3 Phase 11 Kv Line Using Additional Supports Matching With Length And Type Of Existing Support Asper Technical Specifications, Scope Of Works And Approved Drawings 100 Supply Of 8.5 Meter Long / 180 Kg Pcc Poles ( Pcc Pole As Per State Practice ) 101 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Pre-Fabricated Hot Dip Galvanized Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Ms Angle, Ms Flats Pole Extension Canal With Welded Plate, Anti Climbing Device Clamp Etc Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 102 Supply Of Hot Dip Galvanized Ms Nuts, Bolts With Washers And Turn Buckle For Guarding Etc. As Per Technical Specification, Approved Drawings And Scope Of Work. 103 Supply Of Pole Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 104 Supply Of 11 Kv Danger Board 105 Stone Pad ( 300X300x75mm ) 106 Supply Of Gi Barbed Wire 12 Swg 107 Supply For Augmentation Of 3 Phase 11 Kv Line Replacing Existing Conductor With Following Type Of New Acsr Conductor Including Jointing Sleeves, Binding Material And Helicon Formed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 108 Supply Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel By Replacing Existing Weasel / Squirrel Conductor 109 Supply Of 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit By Replacing Existing Weasel / Squirrel Conductor 110 Supply Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog By Replacing Existing Racoon / Rabbit Conductor 111 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work 112 Supply Of 11 Kv 45 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 113 Supply Of 11 Kv 5 Kn Polymer Pin Insulators 114 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Earthing Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 115 Chemicalrod Earthing Including Electrode, Chemical, With 2000Mm Long, 50 Mm Diametergi Pipe, Gi Strip Of 24X3mm Minimum In Hard Rock Locations Only. 116 Supply Of Gi Earthing Spike Made Of 20X2500mm Solid Rod 117 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Stay Set ( Galvanized ) With 50X8 Mm Stay Clamp, Guy Insulator, Anchor Plate ( 200X200x6mm ) , Nut Bolts, 1 No Turn-Buckles, 1.8 M Long 16 Mm Diameter Solid Gi Stay Rod & 7 / 3.15 Mm Dia Gi Strandedwire Complete As Per Technical Specification, Approved Drawings And Scope Of Work. 118 Supply For Augmentation Of 3 Phase 11 Kv Line Using New Gi Wire For Earthing And Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 119 Supply Of 6 Swg Gi Wire 120 Supply Of 8 Swg Gi Wire 121 Supply Of Conductor Accessories As Per Technical Specification, Approved Drawing And Scope Of Work 122 Supply Of Pg Clamp For Weasel To Weasel Conductor 123 Supply Of Pg Clamp For Dog To Dog Conductor 124 Supply Of Pg Clamp For Rabbit To Rabbit Conductor 125 Installation Of Dt Capacitor 126 Supply Of Dt Capacitor With Fitting As Per Technical Specification, Approved Drawing And Scope Of Work 127 Supply Of Lt Shunt Capacitor 440 Volt 10 Kvar 3Phase 50Hz Ip65 128 Supply Of Lt Shunt Capacitor 440 Volt 16 Kvar 3Phase 50Hz Ip65 129 Supply Of Lt Shunt Capacitor 440 Volt 25 Kvar 3Phase 50Hz Ip65 130 Supply Of Lt Shunt Capacitor 440 Volt 40 Kvar 3Phase 50Hz Ip65 131 Supply Of Lt Shunt Capacitor 440 Volt 63 Kvar 3Phase 50Hz Ip65 132 Supply Of Lt Shunt Capacitor 440 Volt 100 Kvar 3Phase 50Hz Ip65 133 Erection Part 134 Installation Of Consumer Service Cable 135 Installation Of Armored Consumer Service Cable With Accessories Including Dismantling Of Existing Service Cable As Per Technical Specifications, Scope Of Works And Approved Drawings 136 Installation Of Single Phase Armored Al Cable Size 2Cx 6 Sq Mm 137 Installation Of Three Phase Armored Al Cable Size 4Cx 16 Sq Mm 138 Gi Wire 8 Swg 139 Gi Wire 10 Swg 140 Erection For Conversion Of Existing Lt Lines On Bare Conductor To Aerial Bunch Xlpe Cable 141 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil Of Following Pole As Per Scope Of Work, Approved Drawings And Specifications: 142 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 143 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Soft Rock Where Blasting Is Not Required As Per Scope Of Work, Approved Drawings And Specifications: 144 Erection Of 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 145 Erection Of Following Types Of Poles For Lt Overhead Line With Stone Pad, Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Pole Numbering By Paint With Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 146 Erection Of 8.5 M / 180 Kgs Pcc Poles With Base Stone Pad As Required - ( State Practices Of Pcc Pole And Stone Pad To Be Used ) 147 Excavation Of Lt Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 148 Normal Soil 149 Erection Of Soft Rock Soil Where Blasting Is Not Required 150 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.2 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 151 Removal Of Existing Lt Bare Line Conductor & Fixtures, Depositing To Stores Of Employer And Erection, Testing & Commissioning Of New Areal Bunched Xlpe Cable, Fixing Tension Clamps For Dead End, Suspension Clamps, Clamps For Neutral, Piercing Connectors Type-I & Type-Ii, Pre- Insulated Compression Connectors, 16 Mm Dia Ms Nuts & Bolts, Pole Clamps, Stainless Steel Strap, Single And Three Phase Pole Mounted Distribution Board, Energisation Of Distribution Box Through 1X25 Sqmm Xlpe Cable Fixing End Cap Etc. As Required As Per Technical Specification, Approved Drawings And Scope Of Work: 152 Erection Of Aerial Bunched Xlpe Cable3 X 50 Sqmm +1X35 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 153 Erection Of Aerial Bunched Xlpe Cable 3 X 70 Sqmm +1X50 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 154 Erection Of Aerial Bunched Xlpe Cable 3 X 95 Sqmm +1X70 Sqmm ( Bare Messenger Cum Neutral ) + 1X16 Sqmm 155 Erection Of Aerial Bunched Xlpe Cable 3 X 120 Sqmm+ 1X95 Sqmm ( Bare Messenger Cum Neutral ) +1X16 Sqmm 156 Erection, Testing & Commissioning Of Earthing By Inserting Gi Earthing Spike Made Of 20Mm Solid Rod As Per Approved Drawings, Scope Of Work And Technical Specifications 157 Erection Of 8 Swg Gi Wire For Earthing By Providing Gi Nut, Bolts & Washers, Turn Buckle Etc As Per Approved Drawings, Scope Of Work And Technical Specifications 158 Erection, Testing And Commissioning Of New 11 Kv Lines: Feeder Segregation ( Agriculture Feeder ) 159 Survey, Route Alignment & Pole Spotting, Preparation Of Survey Report And Uploading In The Web Portal After Approval Of Project Manager 160 Excavation Of Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil For Following Type Pole As Per Scope Of Work, Approved Drawings And Specifications: 161 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 162 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) - Cement Concreting 0.65 Cmt 163 Excavation Of Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Soft Rock For Following Type Pole Where Blasting Is Not Required As Per Scope Of Work, Approved Drawings And Specifications: 164 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 165 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) - Cement Concreting 0.65 Cmt 166 Excavation Of Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Hard Rock For Following Type Pole Where Blasting Is Required As Per Scope Of Work, Approved Drawings And Specifications: 167 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 168 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) - Cement Concreting 0.65 Cmt 169 Erection Of Following Types Of Poles For 11 Kv Overhead Line By Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Red Oxide & Aluminum Painting To Stp Poles Including Paint, Numberingof Poleby Paint Including Cement Concrete Foundation Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 170 Erection Of 8.5 M / 180 Kgs Pcc Poles With Base Pad Including Cement Concreting, ( State Practices Of Pcc Pole, Stone To Be Used ) 171 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) - Cement Concreting 0.65 Cmt 172 Erection, Testing & Commissioning Of Pre-Fabricated Hdg Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures And Ms Nuts, Bolts & Washersas Per Technical Specification, Approved Drawings And Scope Of Work. 173 Earthing Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 174 Erection, Testing & Commissioning Of Spike Earthing 20Mm X 2500Mm Solid Rod 175 Excavation, Erection, Testing & Commissioning Of Chemicalrod Earthing Including Electrode, Chemical, With 2000Mm Long, 50 Mm Diametergi Pipe, Gi Strip Of 24X3mm Minimum In Hard Rock Locations Only. 176 Excavation Of Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 177 Normal Soil 178 Erection Of Soft Rock Soil Where Blasting Is Not Required 179 Erection Of Hard Rock Soil Where Blasting Is Required 180 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator ( 1 Nos. ) And 0.2 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 181 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 182 Erection Of 5 Kn 11 Kv Polymer Pin Insulator 183 Erection Of 45 Kn 11 Kv Polymer Disc Insulator With Strain Hardware 184 Laying Out, Tensioning, Binding Of Conductor And Tightening Of Stays And Stringing, Testing And Commissioning Of Acsrconductor Of Following Sizes Including Jointing Sleeves, Helical Formed Fittings, Jumpering And By Providing & Erecting Pg Clamps Etc As Required As Per Approved Drawings, Scope Of Work And Technical Specifications 185 Stringing Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel 186 Erection, Testing And Commissioning Of Vertical Type 11 Kvab Switch Along With Support Insulators, Base Channel, Down Pipe, Arcing Horns Etc. Complete Asper Technical Specifications, Scope Of Works And Approved Drawings 187 Erection, Testing & Commissioning Of 11 Kv Line For Under Ground Railway Crossing By2 Nos ( Including One Spare ) 3Cx185 Sqmm Xlpe Armored Cable ( 0.3 Km Each ) , Using 150Mm Dia Gi Pipes, Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, 4 Nosgi 3-Meters Long Earthing Pipe, 6 Swg Gi Wires, Cable Markers, Clamps, Jumpering And 11 Kv Station Type Lightening Arrestors ( 6 Nos. ) , Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of He Work. 188 Erection, Testing & Commissioning Of 11 Kv Line For Under Ground Highway Crossing By2 Nos ( Including One Spare ) 3Cx185 Sqmm Xlpe Armored Cable ( 0.3 Km Each ) , Using 160 Mm Hdpe Pipe At Road Crossing, 150Mm Dia Gi Pipes For Cable Support, Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, 4 Nosgi 3-Meters Long Earthing Pipe, 6 Swg Gi Wires, Cable Markers, Clamps, Jumpering, 11 Kv Station Type Lightening Arrestors ( 6 Nos. ) , Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of He Work. 189 Erection Of 12 Kv, 1250 A, 25Ka For 3 Seconds, 3-Ph, Indoor Typevacuum Circuit Breaker With Adopter Panel For Out Going Feeder By Leveling, Alignment And Welding On Existing Cable Trench In Control Room. Testing & Commissioning Of Indoor Vcb Panel Including 3 Nos Indoor Type Current Transformer, A-Meter, Volt-Meter, Relay & Accessories Protection As Per Approved Drawings, Technical Specifications And Scope Of The Work.: 190 Laying, Erection, Termination Using Indoor & Outdoor Termination Kit, 11Kv 3X 185 Sqmm Xlpearmored Power Cablesas Per Technical Specifications, Approved Drawings And Scope Of Works. : 191 Erection, Testing & Commissioning Of New Gi Wire For Earthing And Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 192 Erection Of 6 Swg Gi Wire 193 Erection Of 8 Swg Gi Wire 194 Extension Of Control Room Of 33 / 11 Kv Substation To Accommodate Vcb For New 11 Kv Feeders As Per Technical Specification, Approved Drawing And Scope Of Work. 195 Design, Engineering Construction Of Control Room Building Extension 300 Sq Feet Including Cost Ofall Materials, T&P And Labour, Etc. As Per Technical Specification And Approved Drawing As Per Direction Of Employer 196 Shifting Of Following Distribution Transformer Along With Fixture Including Dismantling , Shifting And Erection From One Location To Another Location As Per Approved Survey. 197 Single Phase Transformer 198 Three Phase Transformer 199 Erection For Augmentation Of Lines 200 Erection For Augmentation Of 33 Kv Line 201 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 202 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 203 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Soft Rock Where Blasting Is Not Required As Per Scope Of Work, Approved Drawings And Specifications: 204 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 205 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Hard Rock Where Blasting Is Required As Per Scope Of Work, Approved Drawings And Specifications: 206 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 207 Erection Of Following Types Of Additional Poles Matching With Existing Line Supports By Providing And Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Painting With Red Oxide & Aluminum Including Paint, Pole Numbering Including Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 208 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) 209 Excavation Of Stay Pit For 33 Kv Stay In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 210 Normal Soil 211 Soft Rock Soil Where Blasting Is Not Required 212 Hard Rock Soil Where Blasting Is Required 213 Erection Of Complete Stay Set With Gi Stay Wire ( 7X4.00 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.3 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 214 Erection, Testing And Commissioning Of 33 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 215 Erection Of 33 Kv 10 Kn Pin Insulator With Gi Pin 216 Erection Of 33 Kv 70 Kn Disc Insulator With Strain Hardware ( Set Of 3, 11 Kv Disc Insulators ) 217 Erection, Testing & Commissioning Of New Pre-Fabricated Hdg Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 218 Dismantling Of Existing Overhead Line Conductor And Fittings, Depositing The Dismantled Material To EmployerS Store And Laying Out & Stringing Of New Acsr Conductor Of Following Sizes By Providing Jointing Sleeves, Binding Wire & Tape & Helical Formed Fittings Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 219 Stringing Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog Replacing Existing Racoon Conductor 220 Stringing Of 30 / 3.00 + 7 / 3.00 Mm ( 200 Mm² Al. Area ) - Panther Replacing Existing Dog / Racoon Conductor 221 Erection, Testing & Commissioning Of 33 Kvunder Ground Cable By2 Nos ( Including One Spare ) 3Cx300 Sqmm Xlpe Armored Cable, Using 160 Mm Hdpe Pipe At Road Crossing, 150Mm Dia Gi Pipes For Cable Support, Outdoor Heat Shrinkable Cable Jointing Kits, Lugs, Cable Markers, Clamps, Jumpering 7 / 20 Gi Wire Etc As Required As Per Technical Specifications, Approved Drawings And Scope Of He Work. 222 Erection For Augmentation Of 3 Phase 33 Kv Line Using New Insulator And Hardware As Per Technical Specification, Approved Drawings And Scope Of Work 223 Erection Of 33 Kv 70 Kn Polymer Disc Insulator Along With Suitable Hardware Fittings 224 Erection Of 33 Kv 10 Kn Polymer Pin Insulators 225 Erection, Testing & Commissioning Of Earthing As Per Technical Specifications, Approved Drawings And Scope Of Work. 226 8 Swg Gi Coil 115 Turns ( 1.85 Kg ) 227 Excavation, Erection, Testing & Commissioning Of Chemicalrod Earthing Including Electrode, Chemical, With 2000Mm Long, 50 Mm Diametergi Pipe, Gi Strip Of 24X3 Mm Minimum In Hard Rock Locations Only. 228 Erection, Testing & Commissioning Of New Gi Wire For Earthing And Guarding As Per Technical Specification, Approved Drawings And Scope Of Work. 229 Erection Of 6 Swg Gi Wire 230 Erection Of 8 Swg Gi Wire 231 Erection For Augmentation Of 11 Kv Lines 232 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 233 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 234 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Soft Rock Where Blasting Is Not Required As Per Scope Of Work, Approved Drawings And Specifications: 235 8.5 M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 236 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Hard Rock Where Blasting Is Required As Per Scope Of Work, Approved Drawings And Specifications: 237 Erection Of 8.5M / 180 Kgs Pcc Poles - ( Pcc Pole As Per State Practice ) 238 Erection Of Following Types Of Poles For 11 Kv Overhead Line By Providing And Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Pole Numbering By Paint Including Cement Concrete Foundation Using 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Etc As Per Scope Of Work, Approved Drawings And Specifications: 239 Erection Of 8.5 M / 180 Kgs Pcc Poles Withbase Stone Pad ( State Practices Of Pcc Pole And Base Plate / Stone To Be Used ) 240 Excavation Of Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 241 Normal Soil 242 Soft Rock Soil Where Blasting Is Not Required 243 Hard Rock Soil Where Blasting Is Required 244 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator And 0.2 Cmt Concreting 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 245 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 246 Erection Of 11 Kv Pin Insulator With Gi Pin 247 Erection Of 11 Kv Disc Insulator With Strain Hardware 248 Dismantling Of Existing Overhead Line Conductor & Fittings And Depositing To EmployerS Store, Laying Out, Tensioning, Binding Of New Conductor And Tightening Of Stays And Stringing, Testing And Commissioning Of Acsrconductor Of Following Sizes Including Jointing Sleeves, Helical Formed Fittings, Jumpering And By Providing & Erecting Pg Clamps Etc As Required As Per Approved Drawings, Scope Of Work And Technical Specifications 249 Stringing Of 6 / 2.59 + 1 / 2.59 Mm ( 30 Mm² Al. Area ) - Weasel By Replacing Existing Weasel / Squirrel Conductor 250 Stringing Of 6 / 3.35 + 1 / 3.35 Mm ( 50 Mm² Al. Area ) - Rabbit By Replacing Existing Weasel / Squirrel Conductor 251 Stringing Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog By Replacing Existing Racoon / Rabbit Conductor 252 Erection, Testing & Commissioning Of Pre-Fabricated Hdg Steel Items Like V Cross Arm, Top Clamp, Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures And Hdg Ms Nuts, Bolts & Washers As Per Technical Specification, Approved Drawings And Scope Of Work. 253 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 254 Erection Of 5 Kn 11 Kv Polymer Pin Insulator 255 Erection Of 45 Kn 11 Kv Polymer Disc Insulator With Strain Hardware 256 Earthingand Guarding Arrangement As Per Technical Specifications, Approved Drawings And Scope Of Work. 257 Erection, Testing & Commissioning Of Spike Earthing 20Mm Solid Rod 258 Excavation, Erection, Testing & Commissioning Of Chemicalrod Earthing Including Electrode, Chemical, With 2000Mm Long, 50 Mm Diametergi Pipe, Gi Strip Of 24X3mm Minimum In Hard Rock Locations Only. 259 Erection Of 8 Swg Gi Wire For Earthing And Guarding 260 Erection Of 6 Swg Gi Wire For Earthing And Guarding 261 Erection Of Dt Capacitor 262 Erection, Testing & Commissioning Offollowing 440 Volt Lt Shunt Capacitor Including Mounting Structure And Accessories As Required As Per Technical Specifications, Approved Drawings And Scope Of Work. 263 Erection Of Lt Shunt Capacitor 440 Volt 10 Kvar 3Phase 50Hz Ip65 264 Erection Of Lt Shunt Capacitor 440 Volt 16 Kvar 3Phase 50Hz Ip65 265 Erection Of Lt Shunt Capacitor 440 Volt 25 Kvar 3Phase 50Hz Ip65 266 Erection Of Lt Shunt Capacitor 440 Volt 40 Kvar 3Phase 50Hz Ip65 267 Erection Of Lt Shunt Capacitor 440 Volt 63 Kvar 3Phase 50Hz Ip65 268 Erection Of Lt Shunt Capacitor 440 Volt 100 Kvar 3Phase 50Hz Ip65 269 Words

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-May-2022 Corrigendum Other 20-05-2022
2 18-May-2022 TIME EXTENSION Date 03-06-2022
3 20-May-2022 Re-Corrigendum Other 03-06-2022

Key Value

Document Fees
INR 29500 /-
EMD
INR 50000000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: DEVELOPMENT OF DISTRIBUTION INFRASTRUCTURE OF PACKAGEMIRZAPUR AT MIRZAPUR, SONBHADRA AND SANT RAVIDAS NAGAR DISTRICT OF PuVVNLUTTAR PRADESHUNDERREVAMPED REFORMS-BASED AND RESULTS-LINKED, DISTRIBUTION SECTOR SCHEME
Sl. No. Item Description
1Supply of Consumer Service Cable
2Supply of Armored service cable for consumer service connection with accessories as per technical specifications, scope of works and approved drawings
3Supply of Single Phase armored AL cable size 2CX 6 Sq mm
4Supply of Three Phase armored AL cable size 4CX 16 Sq mm
5Supply of 10 SWG GI wire
6Supply of 8 SWG GI wire
7Conversion of existing LT lines on bare conductor to Areal bunch XLPE cable
8Conversion of existing LT lines with bare conductor to AB XLPE cable using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings
9Supply of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice)
10Galvanized Stay Set for LT line with anchor plate (200x200x6mm), 50x8mm stay clamp, Stay guy insulator, nut bolts, 1 Nos turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work.
11Conversion of existing LT lines using new Earthing as per approved drawings, technical specifications and scope of work
12Supply of Spike Earthing made of 20mm X 2500 mm GI solid Rod
13Supply of 8 SWG GI wire for earthing and guarding
14Supply of following LT AB XLPE Cable for Conversion of existing LT bare conductor line with AB XLPE Cable as required as per technical specification, approved drawings and scope of work:
15Supply of Aerial bunchedXLPE cable 3 X 50 sqmm+1x35 sqmm.(bare messenger wire)+1x16 sqmm.
16Supply of Aerial bunchedXLPE cable 3 X 70 sqmm.+1x50 sqmm.(Bare messenger wire)+1x16 sqmm.
17Supply of Aerial bunchedXLPE cable 3 X 95 sqmm.+1x70 sqmm.( bare messenger wire)+ 1x16 sqmm.
18Supply of Aerial bunchedXLPE cable 3 X 120 sqmm. + 1x95 sqmm.(bare messenger wire) +1x16 sqmm.
19Supply of Pole mounted LT Distribution box as per approved drawings, technical specifications and scope of work
20Supply of Three phase SMC Distribution box with clamps
21Supply of Single phase SMC Distribution box with clamps
22Supply of XLPE insulated Al. cable for energisation of distribution box/ Kiosk as per approved drawings, technical specifications and scope of work
23Supply of 1x25 mm2 XLPE insulated Al.cable
24Supply of Stone pad (300x300x75)
25Supply of Accessories for AB XLPE Cable as per approved drawings, technical specifications and scope of work
26Stainless steel Strap
27HDG LT Pole Clamp with nut & bolt for laying ABC
28Dead end Clamp with I-Hook( Insulated)
29Suspension Clamp with I-Hook ( Insulated)
3095/35 Sqmm - 70/25 sqmm PG Clamps( for line to line jumpering & energizing DB neutral)
31120/50 Sqmm - 95/25 sqmm PG Clamps( for line to line jumpering & energizing DB neutral)
32LT Insulation piercing connector 120-50 sqmm - 50-25 sqmm size (for energizing distribution box)
33LT Insulation piercing connector 120-50 sqmm - 120-50 sqmm size (for line to line jumpering)
34LT Insulation piercing connector 16 - 25sqmmsize suitable for street light connection
35Pre-Insulated Compression connectors size 16 sqmm suitable for AB XLPE cable
36Pre-Insulated Compression connectors size 50 sqmm suitable for AB XLPE cable
37Pre-Insulated Compression connectors size 70 sqmm suitable for AB XLPE cable
38Pre-Insulated Compression connectors size 95 sqmm suitable for AB XLPE cable
39Pre-Insulated Compression connectors size 120 sqmm suitable for AB XLPE cable
40Heat shrinkable type end cap for AB XLPE cable
41Supply of New 11 KV Lines : feeder Segregation ( Agriculture Feeder)
42Supply of Support for 11 KV overhead line as per technical specification, approved drawings and scope of work
43Supply of 8.5m/180 kgs PCC Poles - (PCC Pole as per state practice)
44Supply of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
45Supply for 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top clamp, Cross arm, Bracket, Clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS transformer base channel, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
46Supply of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding etc. as per technical specification, approved drawings and scope of work.
47Supply of Pole accessories as per technical specification, approved drawing and scope of work
48Supply of 11 KV danger board
49Supply of Stone Pad 300X300X75
50Supply of Barbed GI wire 12 SWG
51Supply of Stay Set (Galvanized) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
52Supply of Insulator and hardware as per technical specification, approved drawings and scope of work.
53Supply of 11 KV45 KN polymer Disc insulator along with suitable hardware fittings
54Supply of 11 KV 5 KN Polymer Pin Insulators
55Supply of Earthing arrangement as per technical specifications,approved drawings and scope of work.
56Supply of Spike Earthing 20mm X 2500 mm solid Rod
57Chemicalrod earthing including electrode, chemical, with 2000mm long, 50 mm diameterGI pipe, GI Strip of 24x3mm minimum in hard rock locations only.
58Supply of 8 SWG GI wire for earthing and guarding
59Supply of 6 SWG GI wire for earthing and guarding
60Supply of ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work
61Supply of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel
62Supply of 11 kV, 600A,3-ph, 3 Pin type, Vertical Mounting type, Gang Operated,AB Switch along with Support Insulators, Base Channel down Pipe, Arcing Horns etc. complete asper technical specifications, scope of works and approved drawings
63Supply of 11 KV Lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work
64Supply for 11 KV lineunder ground Railway crossing with 2 nos (Including one spare) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) using 150mm dia GI pipes (grade A for underground laying and grade B for pole support), Outdoor heat shrinkable cable jointing kit, 11 KV LIGHTENING ARRESTOR STATION CLASS 10KA (6 NOS.), LUGS, 4 Nos GI 3-Meters LONG pipe EARTHING, 6 SWG GI WIRES, CABLE MARKERS, BI METALLICK CLAMPS and JUMPERING etc AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK.
65Supply of 11 LV Line underground Highway crossing ensuring statutory clearancesas required as per technical specification, approved drawings and scope of work
66Supply of 11 KV LINEFORUNDER GROUND Highway CROSSING BY 2 Nos (INCLUDING ONE SPARE) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) USING 160 mm HDPE pipe at road crossing and 150MM DIA GI PIPES (gradeB for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS, 11 KV LIGHTENING ARRESTOR STATION CLASS 10KA (6 NOS.), LUGS, 4 Nos GI 3-Meters LONG pipe EARTHING, 6 SWG GI WIRES, CABLE MARKERS, BI METALLICK CLAMPS and JUMPERING etc AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK.
67Supply of 12 KV 3ph Indoor type switch gear and 11 KV XLPE cable as per technical specifications, approved drawings and scope of works:
68Supply of Indoor type 12 KV 3 Ph 1250 A VCB with control and protection system for out going feeder consisting ofCT, A-meter, volt-meter, Relays, energy meter (TVM) DLMS compliant & accessories complete as per specifications for feeder breaker protection
6911 KV 3X 185 sqmm XLPE armored Power cable, aluminum stranded conductor, including their termination materials like indoor and outdoor termination kit, glands, lugs, tagging, cable path marker etc as required as per technical specifications, approved drawings and scope of the works.
70Supply for Augmentation of lines
71Supply for Augmentation of 33 KV Line
72Supply for Augmentation of 3 phase 33 kV line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings
73Supply of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
74Supply New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
75Supply of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle etc. as per technical specification, approved drawings and scope of work.
76Supply of Pole accessories as per technical specification, approved drawing and scope of work
77Supply of 33 KV danger board
78Supply of GI Barbed wire 12 SWG
79Supply for Augmentation of 3 phase 33 kV line replacing existing conductor with following type of new ACSR conductor including jointing sleeves, binding material, aluminum tape and helical Preformed fittings etc as required as per technical specification, approved drawings and scope of work.
80Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog replacing existing racoon conductor
81Supply of 30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther replacing existing dog/racoon conductor
82Supply of 33 KV Under ground cable as per technical specification, approved drawings and scope of work.
83Supply of 3CX300 Sqmm 33 KV XLPE Armored Cable
84Supply of Accessories for 33 KV3Cx300 Sqmm XLPE Armored Cable (2 Nos including one spare),like 160mm dia HDPE pipes for road crossing and 150 mm dia GI pipegrade B for pole support outdoor heat shrinkable cable jointing kits, Lugs,CablePath markers, bi metallic clamps and 7/20 GI wire as per technical specification, approved drawing and scope of work
85Supplyof new Insulator and hardware for Augmentation of33 kV line as per technical specification, approved drawings and scope of work
86Supply of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings
87Supply of 33 KV 10 KN Polymer Pin Insulators
88Supply of new Earthing arrangement for Augmentation of33 kV line as per technical specifications,approved drawings and scope of work.
898 SWG GI Coil 115 turns (1.85 kg)
90Chemicalrod earthing including electrode, chemical, with 2000mm long, 50 mm diameterGI pipe, GI Strip of 24x3mm minimum in hard rock locations only.
91Supply of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, guy insulator, anchor plate (300x300x8mm) , nut bolts, turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
92Supply of new GI wire for earthing and guarding for Augmentation of33 kV line as per technical specification, approved drawings and scope of work.
93Supply of 6 SWG GI wire
94Supply of 8 SWG GI wire
95Supply of Conductor accessories as per technical specification, approved drawing and scope of work
96Supply of PG Clamp for Dog to Dog conductor
97Supply of PG Clamp for Panther to Panther conductor
98Supply for Augmentation of 11 KV lines
99Supply for Augmentation of 3 phase 11 kV line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings
100Supply of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice)
101Supply for Augmentation of 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
102Supply of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding etc. as per technical specification, approved drawings and scope of work.
103Supply of Pole accessories as per technical specification, approved drawing and scope of work
104Supply of 11 KV danger board
105Stone Pad(300x300x75mm)
106Supply of GI Barbed wire 12 SWG
107Supply for Augmentation of 3 phase 11 kV line replacing existing conductor with following type of new ACSR conductor including jointing sleeves, binding material and helicon formed fittings etc as required as per technical specification, approved drawings and scope of work.
108Supply of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel by replacing existing weasel/squirrel conductor
109Supply of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit by replacing existing weasel/squirrel conductor
110Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit conductor
111Supply for Augmentation of 3 phase 11 kV line using new Insulator and hardware as per technical specification, approved drawings and scope of work
112Supply of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings
113Supply of 11 KV 5 KN Polymer Pin Insulators
114Supply for Augmentation of 3 phase 11 kV line using new Earthing arrangement as per technical specifications,approved drawings and scope of work.
115Chemicalrod earthing including electrode, chemical, with 2000mm long, 50 mm diameterGI pipe, GI Strip of 24x3mm minimum in hard rock locations only.
116Supply of GI Earthing spike made of 20x2500mm solid Rod
117Supply for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 No turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work.
118Supply for Augmentation of 3 phase 11 kV line using new GI wire for earthing and guarding as per technical specification, approved drawings and scope of work.
119Supply of 6 SWG GI wire
120Supply of 8 SWG GI wire
121Supply of Conductor accessories as per technical specification, approved drawing and scope of work
122Supply of PG Clamp for Weasel to Weasel conductor
123Supply of PG Clamp for Dog to Dog conductor
124Supply of PG Clamp for Rabbit to Rabbit conductor
125Installation of DT Capacitor
126Supply of DT Capacitor with Fitting as per Technical Specification, Approved Drawing and scope of work
127Supply of LT Shunt capacitor 440 Volt 10 KVAr 3Phase 50Hz IP65
128Supply of LT Shunt capacitor 440 Volt 16 KVAr 3Phase 50Hz IP65
129Supply of LT Shunt capacitor 440 Volt 25 KVAr 3Phase 50Hz IP65
130Supply of LT Shunt capacitor 440 Volt 40 KVAr 3Phase 50Hz IP65
131Supply of LT Shunt capacitor 440 Volt 63 KVAr 3Phase 50Hz IP65
132Supply of LT Shunt capacitor 440 Volt 100 KVAr 3Phase 50Hz IP65
133Erection Part
134Installation of Consumer Service Cable
135Installation of Armored consumer service cable with accessories including dismantling of existing service cable as per technical specifications, scope of works and approved drawings
136Installation of Single Phase armored AL cable size 2CX 6 Sq mm
137Installation of Three Phase armored AL cable size 4CX 16 Sq mm
138GI Wire 8 SWG
139GI Wire 10 SWG
140Erection for Conversion of existing LT lines on bare conductor to Aerial bunch XLPE cable
141Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil of following pole as per scope of work, approved drawings and specifications:
1428.5 m/180 kgs PCC Poles - (PCC Pole as per state practice)
143Excavation of additional pole pit (of depth 1/6th of pole length) in soft rock where blasting is not required as per scope of work, approved drawings and specifications:
144Erection of 8.5 m/180 kgs PCC Poles - (PCC Pole as per state practice)
145Erection of following types of poles for LT overhead line with Stone pad, danger plate, anti-climbing devices (barbed wire), pole numbering by paint with cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications:
146Erection of 8.5 m/180 Kgs PCC Poles with base stone Pad as required - (state practices of PCC pole and stone Pad to be used)
147Excavation of LT stay pit in following type of soils,as per scope of work, approved drawings and specifications:
148Normal soil
149Erection of Soft rock soil where blasting is not required
150Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
151Removal of existing LT bare line conductor & fixtures, depositing to stores of employer and erection, testing & commissioning of new areal bunched XLPE cable, Fixing tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type-I & type-II, Pre- insulated compression connectors, 16 mm dia MS nuts & bolts, pole clamps, stainless steel strap, Single and three phase pole mounted distribution board, energisation of distribution box through 1x25 sqmm XLPE cable fixing end cap etc. as required as per technical specification, approved drawings and scope of work:
152Erection of Aerial Bunched XLPE Cable3 X 50 sqmm +1x35 sqmm ( bare messenger cum neutral ) +1x16 sqmm
153Erection of Aerial Bunched XLPE Cable 3 X 70 sqmm +1x50 sqmm ( bare messenger cum neutral )+1x16 sqmm
154Erection of Aerial Bunched XLPE Cable 3 X 95 sqmm +1x70 sqmm ( bare messenger cum neutral )+ 1x16 sqmm
155Erection of Aerial Bunched XLPE Cable 3 X 120 sqmm+ 1x95 sqmm ( bare messenger cum neutral ) +1x16 sqmm
156Erection, testing & commissioning of earthing by inserting GI Earthing spike made of 20mm solid Rod as per approved drawings, scope of work and technical specifications
157Erection of 8 SWG GI wire for earthing by providing GI nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications
158Erection, testing and Commissioning of New 11 KV lines: Feeder Segregation (Agriculture Feeder)
159Survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of Project Manager
160Excavation of pole pit (of depth 1/6th of pole length) in normal soil for following type pole as per scope of work, approved drawings and specifications:
1618.5 m/180 kgs PCC Poles - (PCC Pole as per state practice)
16211 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.65 cmt
163Excavation of pole pit (of depth 1/6th of pole length) in soft rock for following type pole where blasting is not required as per scope of work, approved drawings and specifications:
1648.5 m/180 kgs PCC Poles - (PCC Pole as per state practice)
16511 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.65 cmt
166Excavation of pole pit (of depth 1/6th of pole length) in hard rock for following type pole where blasting is required as per scope of work, approved drawings and specifications:
1678.5 m/180 kgs PCC Poles - (PCC Pole as per state practice)
16811 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.65 cmt
169Erection of following types of poles for 11 KV overhead line by installing danger plate, anti-climbing devices (barbed wire), red oxide & aluminum painting to STP poles including paint, numberingof poleby paint including cement concrete foundation using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4)etc as per scope of work, approved drawings and specifications:
170Erection of 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used)
17111 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.65 cmt
172Erection, testing & commissioning of pre-fabricated HDG steel items like V cross arm, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures and MS nuts, bolts & washersas per technical specification, approved drawings and scope of work.
173Earthing arrangement as per technical specifications,approved drawings and scope of work.
174Erection, testing & commissioning of Spike Earthing 20mm x 2500mm solid Rod
175Excavation, erection, testing & commissioning of Chemicalrod earthing including electrode, chemical, with 2000mm long, 50 mm diameterGI pipe, GI Strip of 24x3mm minimum in hard rock locations only.
176Excavation of stay pit in following type of soils,as per scope of work, approved drawings and specifications:
177Normal soil
178Erection of Soft rock soil where blasting is not required
179Erection of Hard rock soil where blasting is required
180Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 Nos.) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
181Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.
182Erection of 5 KN 11 kV Polymer Pin insulator
183Erection of 45 KN 11 kV Polymer Disc insulator with strain hardware
184Laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of ACSRConductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications
185Stringing of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel
186Erection, Testing and Commissioning of vertical type 11 kVAB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete asper technical specifications, scope of works and approved drawings
187Erection, testing & commissioning of 11 KV line for under ground railway crossing by2 Nos (including one spare) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) , using 150MM dia GI pipes, outdoor heat shrinkable cable jointing kits, lugs,4 NosGI 3-meters long earthing pipe, 6 SWG GI wires, cable markers, clamps, jumpering and 11 KV station type lightening arrestors(6 NOS.), etc as required as per technical specifications, approved drawings and scope of he work.
188Erection, testing & commissioning of 11 KV line for under ground highway crossing by2 Nos (including one spare) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) , using 160 mm HDPE pipe at road crossing, 150MM dia GI pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs,4 NosGI 3-meters long earthing pipe, 6 SWG GI wires, cable markers, clamps, jumpering, 11 KV station type lightening arrestors(6 NOS.), etc as required as per technical specifications, approved drawings and scope of he work.
189Erection of 12 kV, 1250 A, 25kA for 3 seconds, 3-ph, indoor typeVacuum Circuit breaker with adopter panel for out going feeder by leveling, alignment and welding on existing cable trench in control room. Testing & commissioning of indoor VCB panel including 3 Nos indoor type Current Transformer,A-meter, volt-meter, Relay & accessories protection as per approved drawings, technical specifications and scope of the work.:
190Laying, erection, termination using indoor & outdoor termination kit, 11KV 3x 185 sqmm XLPEarmored Power cablesas per technical specifications, approved drawings and scope of works. :
191Erection, testing & commissioning of new GI wire for earthing and guarding as per technical specification, approved drawings and scope of work.
192Erection of 6 SWG GI wire
193Erection of 8 SWG GI wire
194Extension of Control room of 33/11 KV Substation to accommodate VCB for new 11 KV feeders as per technical specification, approved drawing and scope of work.
195Design, Engineering construction of Control room building extension 300 Sq feet including cost ofall materials, T&P and Labour,etc. as per Technical specification and approved drawing as per direction of Employer
196Shifting of following Distribution Transformer along with fixture including dismantling , shifting and erection from one location to another location as per approved survey.
197Single Phase Transformer
198Three Phase Transformer
199Erection for Augmentation of lines
200Erection for Augmentation of 33 KV Line
201Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil as per scope of work, approved drawings and specifications:
20211 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
203Excavation of additional pole pit (of depth 1/6th of pole length) in soft rock where blasting is not required as per scope of work, approved drawings and specifications:
20411 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
205Excavation of additional pole pit (of depth 1/6th of pole length) in hard rock where blasting is required as per scope of work, approved drawings and specifications:
20611 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
207Erection of following types of additional poles matching with existing line supports by providing and installing danger plate, anti-climbing devices (barbed wire),painting with red oxide & aluminum including paint, pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications:
20811 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
209Excavation of stay pit for 33 KV Stay in following type of soils,as per scope of work, approved drawings and specifications:
210Normal soil
211Soft rock soil where blasting is not required
212Hard rock soil where blasting is required
213Erection of complete stay set with GI stay wire (7x4.00 mm dia), binding of stay wire, by providing Guy stay insulator and 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
214Erection, testing and commissioning of 33 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.
215Erection of 33 kV 10 KN Pin insulator with GI pin
216Erection of 33 kV 70 KN Disc insulator with strain hardware (set of 3, 11 KV disc insulators)
217Erection, testing & commissioning of new Pre-fabricated HDG steel items like V cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures as per technical specification, approved drawings and scope of work.
218Dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employer"s store and laying out & stringing of new ACSR conductor of following sizes by providing jointing sleeves, binding wire & tape & helical formed fittings etc as required as per technical specification, approved drawings and scope of work.
219Stringing of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog replacing existing racoon conductor
220Stringing of 30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther replacing existing dog/racoon conductor
221Erection, testing & commissioning of 33 KVunder ground Cable by2 Nos (including one spare) 3Cx300 Sqmm XLPE Armored Cable, using 160 mm HDPE pipe at road crossing, 150mm dia GI pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, cable markers, clamps, jumpering 7/20 GI wire etc as required as per technical specifications, approved drawings and scope of he work.
222Erection for Augmentation of 3 phase 33 kV line using new Insulator and hardware as per technical specification, approved drawings and scope of work
223Erection of 33 KV 70 KN polymer Disc insulator along with suitable hardware fittings
224Erection of 33 KV 10 KN Polymer Pin Insulators
225Erection, testing & commissioning of earthing as per technical specifications,approved drawings and scope of work.
2268 SWG GI Coil 115 turns (1.85 kg)
227Excavation, erection, testing & commissioning of Chemicalrod earthing including electrode, chemical, with 2000mm long, 50 mm diameterGI pipe, GI Strip of 24x3 mm minimum in hard rock locations only.
228Erection, testing & commissioning of new GI wire for earthing and guarding as per technical specification, approved drawings and scope of work.
229Erection of 6 SWG GI wire
230Erection of 8 SWG GI wire
231Erection for Augmentation of 11 KV lines
232Excavation of additional pole pit (of depth 1/6th of pole length) in normal soil as per scope of work, approved drawings and specifications:
2338.5 m/180 kgs PCC Poles - (PCC Pole as per state practice)
234Excavation of additional pole pit (of depth 1/6th of pole length) in soft rock where blasting is not required as per scope of work, approved drawings and specifications:
2358.5 m/180 kgs PCC Poles - (PCC Pole as per state practice)
236Excavation of additional pole pit (of depth 1/6th of pole length) in hard rock where blasting is required as per scope of work, approved drawings and specifications:
237Erection of 8.5m/180 kgs PCC Poles - (PCC Pole as per state practice)
238Erection of following types of poles for 11 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire),pole numbering by paint including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications:
239Erection of 8.5 m/180 Kgs PCC Poles withBase stone pad(state practices of PCC pole and base plate/stone to be used)
240Excavation of stay pit in following type of soils,as per scope of work, approved drawings and specifications:
241Normal soil
242Soft rock soil where blasting is not required
243Hard rock soil where blasting is required
244Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
245Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.
246Erection of 11 kV Pin insulator with GI pin
247Erection of 11 kV Disc insulator with strain hardware
248Dismantling of existing overhead line conductor & fittings and depositing to Employer"s store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of ACSRConductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications
249Stringing of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel by replacing existing weasel/squirrel conductor
250Stringing of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit by replacing existing weasel/squirrel conductor
251Stringing of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit conductor
252Erection, testing & commissioning of pre-fabricated HDG steel items like V cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of MS Channels, MS angle, MS flats of given sizes for over head structures and HDG MS nuts, bolts & washers as per technical specification, approved drawings and scope of work.
253Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.
254Erection of 5 KN 11 kV Polymer Pin insulator
255Erection of 45 KN 11 kV Polymer Disc insulator with strain hardware
256Earthingand guarding arrangement as per technical specifications,approved drawings and scope of work.
257Erection, testing & commissioning of Spike Earthing 20mm solid Rod
258Excavation, erection, testing & commissioning of Chemicalrod earthing including electrode, chemical, with 2000mm long, 50 mm diameterGI pipe, GI Strip of 24x3mm minimum in hard rock locations only.
259Erection of 8 SWG GI wire for earthing and guarding
260Erection of 6 SWG GI wire for earthing and guarding
261Erection of DT Capacitor
262Erection, Testing & Commissioning offollowing 440 Volt LT shunt Capacitor including mounting Structure and accessories as required as per technical specifications,approved drawings and scope of work.
263Erection of LT Shunt capacitor 440 Volt 10 KVAr 3Phase 50Hz IP65
264Erection of LT Shunt capacitor 440 Volt 16 KVAr 3Phase 50Hz IP65
265Erection of LT Shunt capacitor 440 Volt 25 KVAr 3Phase 50Hz IP65
266Erection of LT Shunt capacitor 440 Volt 40 KVAr 3Phase 50Hz IP65
267Erection of LT Shunt capacitor 440 Volt 63 KVAr 3Phase 50Hz IP65
268Erection of LT Shunt capacitor 440 Volt 100 KVAr 3Phase 50Hz IP65
269Words
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail