| 1 | Wiring point for light with 1.5 sq.mm FRLSH P.V.C. insulated multistrandsingle core Copper Conductor cable in PVC conduit 2mm thick with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash.pvc conduit 2mm thick.SI No 138( C) +187(A). |
| 2 | Wiring point for fan with 1.5 sq.mm FRLSH P.V.C. insulated multistrandsingle core Copper Conductor cable in PVC conduit 2mm thick with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash. SI No 140( C) +187(A). |
| 3 | Wiring point for plug with 1.5 sq.mm FRLSH P.V.C. insulated multistrandsinglecore Copper Conductor cable in PVC conduit 2mm thick with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & socket etc, complete in all respect including matching colour wash. SI No 141( C) +187(C). |
| 4 | Supply and burying of 40 mm dia. x 4.5 metres long G.I. pipe vertically for earthing having 12 mm dia. holes spaced 75 mm apart drilled up to 2 metres from the bottom complete with earthing lead of no. 6 to 8 SWG GI wire in G.I. pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board ,30 cm square C.I. box with hinged cover masonary enclousure funnel at top ,alternate layers of charcoal/ coke and salt at least 150 mm thick alround etc. as per directions of engineer-in- charge complete in all respects as per drawing.SI No 701 |
| 5 | Supply and fixing of one number 8 to 6 SWG G.I. Wire in 15mm dia. G.I. Pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sandlabour. T and P other material required for proper completion of the work as directed at site. SI No 721 |
| 6 | SSupply and fixing of 6 to 32Amp Amp MCB (10 KA)C Curve. CatA SI No 1002 |
| 7 | Supply and fixingof 6 Amp to 32 Amp DPMCB (10KA). CCurve. CatA SI No 1009 |
| 8 | Supply and fixing surface/flush mounting 4 ways SPN distribution board with additional metal door withoutMCB complete in all respects, as directed at site by engineer in charge. Cat A. SI No 1022(A) |
| 9 | Supply and fixing surface/flush mounting 8 ways SPN distribution board with additional metal door withoutMCB complete in all respects, as directed at site by engineer in charge. Cat A. SI No 1024(A) |
| 10 | Supply and fixing of hexagonal/ round G.P. fan box of approved make made up of 1.0 mm thick ISI marked G.P. sheet spot welded four to eight holes 25.4 mm for pipe entry of tmm G.P. sheet made upper and lower cover duly screwed fitted with 300 mm round zink coated M.S. Bar x 12 mm and brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof beforeconcreting along with supply of all materials, labor, T & P etc. required forproper completion ofthe work .SI No 1149 |
| 11 | Supply and fixing of power plug with 20A/240 V flush typemodular switchand 5 pin 20 A/250 V flush type universal modular socket, switch on concealed M.S. box including supply of all materials labour T&C etc. required for proper Completion of work. SI No 1139(A) |
| 12 | Supply and fixing of electronic fan regulator(Modular) 120-280 V ISI Marked on the existing switch board including making connection, required, materials, labour T/P for proper completion of work to the satisfaction of engineer in chargeof work. SI No 1203(C) |
| 13 | Supply and wiring of submain with two number 2.5 sqmm FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in20 mm dia heavy gauge(2mm thick ) PVC conduit concealed in wall along with reinforcement befor concreting with one number 1.5 Sqmm FRLSHPVC insulated 1100 volt grade Multistand single core copper conductor cable as earth contunity wire including colour wash etc. complete in all respects. SI No 1304(C) |