Defect Rectification On Various Hullequipment Onboard Icgs Samudra Prahari At Goa - Defect Rectificationon Various Hull Equipment Onboard Icgs Samudra Prahari At Goa 2 H-1044:Sampling Cock Of Dispersant Tank Not Holding And Leaking At Ac Compartment. T, South Goa-Goa

Indian Coast Guard has published Defect Rectification On Various Hullequipment Onboard Icgs Samudra Prahari At Goa - Defect Rectificationon Various Hull Equipment Onboard Icgs Samudra Prahari At Goa 2 H-1044:Sampling Cock Of Dispersant Tank Not Holding And Leaking At Ac Compartment. T. Submission Date for this Tender is 18-05-2022. Coats and Jackets Tenders in South Goa Goa. Bidders can get complete Tender details and download the document.




Tender Notice

32189816
Defect Rectification On Various Hullequipment Onboard Icgs Samudra Prahari At Goa - Defect Rectificationon Various Hull Equipment Onboard Icgs Samudra Prahari At Goa 2 H-1044:Sampling Cock Of Dispersant Tank Not Holding And Leaking At Ac Compartment. T
Limitted
Indian
Goa
South Goa
18-05-2022

Tender Details

Defect Rectification On Various Hullequipment Onboard Icgs Samudra Prahari At Goa - Defect Rectificationon Various Hull Equipment Onboard Icgs Samudra Prahari At Goa 2 H-1044:Sampling Cock Of Dispersant Tank Not Holding And Leaking At Ac Compartment. To Be Renewed As Per The Sample Along With Flanges. Dia-25 Mm, Mat Gm. 3 H-1131:Fire Fighting Arrangement On Both Boats Had Lived Its Fair Life.Both Co2 Cylinders To Be Renewed Along With Its Operating Mechanism And Proved.Cylinder Cap- 09 Ltr 4 H-1152Captain’S Bath Shower Cubicle Sliding Door Uprooted From Channels. 08 No Sliding Wheels To Be Renewed With Holding Bracket. Mat- Brass. Concealed Shower Panel Tower With Shower Head / Hand Shower And Multi-Function Nozzle ( 06 Nos ) To Be Renewed As Per Sample. Mat- Ss. Top Side Panel Cracked, To Be Renewed. Mat – Marine Ply Laminate With Water Proof Coating. 5 H-1158:Fresh Water Cu Line Of Wash Basin Broken At Q Deck Cu Line ( Dia 15 Mm ) Wall Thick- 1.2 Mm, To Be Renewed With Stop Cock / End Fittings And Helo Deck Fresh Water Line Corrode / Deteriorated To Be Renewed As Per The Sample Mat- Cu, Length -6 Mtrs Including The Securing Of Fresh Water Line Brackets To Be Welded. Fresh Water Lines Of Bath Rooms / Wc’S Securing Brackets Uprooted / Deteriorated To Be Renewed As Per The Sample.Qty-20 Nos. 6 H-1159:Life Raft Stands Deteriorated. To Be Renewed As Per Sample. Qty -02 Stands Mat- Ms, Angle – 50X 50X 6 Mm- 50 Mtr, Pipe Dia- 65 Mmx 10 Mtr, Sche-80 Pipe Dia -120 Mm, 9 Mtr. 7 H-1163:80 No U Clamps With Angle Bracket For Securing Deluge Pipes And Fire Main / Hydraulic Pipes At Weather Deck And Q’ Deck Pilot Entrance And Exit Door Hinges Corroded And Perished. To Be Renewed As Per Sample. Mat- U Clamp Ss-306, Angle Bracket- Ms With Rubber Padding. Job Involves Removal And Refitment Of Insulation Below Bracket. Material –Ms-04 No’S 8 H-1179:Water Leakage On One No Bridge Widow Glass To Be Renewed Glass Rubber Beading And Refitted Asper Sample. Lxb -5X3.8 Feet 9 H-1186;0 No’S Fire Man Securing Brackets Rubber Beading Perished To Be Renewed As Per The Sample Includes 03 No’S Glass To Be Renewed As Per The Sample. 15 No’S Fire Extinguishers Securing Stands Uprooted From The Brackets To Be Repaired As Per The Sample And Stbd Side Fire Man Securing Buckets Corroded To Be Renewed As Per The Sample. 10 H-1189:08 No’S Pc Boat Ores Decay To Be Fabricated As Per The Sample And Securing Arrangement To Provide On Pc Boats And 02 No’S Flag Stanchions Shoe And Flag Stanchions To Be Fabricated As Per The Sample. 11 H-1190:Ship’S Galley, Sr Sailor Dining Hall And Jr Sailor Dining Hall Storage Lockers Hinges And Locking Arrangement Uprooted From Base. Hinges To Be Renewed As Per The Sample And Locker To Be Repaired. ( Qty-10 No’S, Mat Hinges - Ss, Locker - Ss 12 H-1191:08 In No’S Awning Supporting Stanchions In Bridge Wing ( Port And Stbd ) Corroded / Deteriorated. To Be Renewed As Per Sample. Awning To Be Stitched. Mat Stanchion -Alawning Size- 200Cm X 130Cm 13 H-1192:Ship’S Galley Wash Basin Drain Pipe Corroded. To Be Repaired / Renewed As Per The Sample. Mat-Ms, 14 H-1193;Ship’S Galley Fcu Drain Pipe Tray Corroded. Insulation, Galley Fresh Water Tap And Non-Return Valve To Be Renewed As Per The Sample. Drain Pipe Size - 1 / 2-Inch And Fuc Pipe Length - 1 Mtr. 15 H-1199:Ship’S Office, Regulating Office, Ops Room, Mso Metallic Drawers Channels Not Working Properly. To Be Repaired / Renewal As Per The Sample. Qty-25 No’S Lockers

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: DEFECT RECTIFICATIONON VARIOUS HULLEQUIPMENT ONBOARD ICGS SAMUDRA PRAHARI AT GOA
Sl. No. Item Description
1DEFECT RECTIFICATIONON VARIOUS HULL EQUIPMENT ONBOARD ICGS SAMUDRA PRAHARI AT GOA
2H-1044:Sampling cock of dispersant tank not holding and leaking at AC compartment. To be renewed as per the sample along with flanges. dia-25 mm, Mat GM.
3H-1131:Fire fighting arrangement on both boats had lived its fair life.Both CO2 cylinders to be renewed along with its operating mechanism and proved.Cylinder Cap- 09 Ltr
4H-1152Captain’s bath shower cubicle sliding door uprooted from channels. 08 no sliding wheels to be renewed with holding bracket. Mat- Brass. Concealed Shower panel tower with shower head/ hand shower and multi-function nozzle (06 nos) to be renewed as per sample. Mat- SS. Top side panel cracked, to be renewed. Mat – Marine ply laminate with water proof coating.
5H-1158:Fresh water Cu line of wash basin broken at Q deck Cu line (dia 15 mm) wall thick- 1.2 mm, to be renewed with stop cock /end fittings and helo deck fresh water line corrode/deteriorated to be renewed as per the sample Mat- Cu, length -6 Mtrs including the securing of fresh water line brackets to be welded. Fresh water lines of bath rooms/ WC’S securing brackets uprooted/deteriorated to be renewed as per the sample.Qty-20 nos.
6H-1159:Life raft stands deteriorated. To be renewed as per sample. Qty -02 stands mat- MS, angle – 50x 50x 6 mm- 50 mtr, pipe dia- 65 mmx 10 mtr, sche-80 pipe dia -120 mm, 9 mtr.
7H-1163:80 no U clamps with angle bracket for securing deluge pipes and fire main/ hydraulic pipes at weather deck and Q’ deck Pilot entrance and exit door hinges corroded and perished. To be renewed as per sample. Mat- U clamp SS-306, angle bracket- MS with rubber padding. Job involves removal and refitment of insulation below bracket. Material –MS-04 no’s
8H-1179:Water leakage on one no bridge widow glass to be renewed glass rubber beading and refitted asper sample. LxB -5x3.8 feet
9H-1186;0 no’s fire man securing Brackets rubber beading perished to be renewed as per the sample includes 03 no’s glass to be renewed as per the sample. 15 no’s fire extinguishers securing stands uprooted from the brackets to be repaired as per the sample and stbd side fire man securing buckets corroded to be renewed as per the sample.
10H-1189:08 no’s PC boat ores decay to be fabricated as per the sample and securing arrangement to provide on pc boats and 02 no’s flag stanchions shoe and flag stanchions to be fabricated as per the sample.
11H-1190:Ship’s galley, Sr sailor dining hall and Jr sailor dining hall storage lockers hinges and locking arrangement uprooted from base. Hinges to be renewed as per the sample and locker to be repaired. (Qty-10 no’s, Mat Hinges - SS, Locker - SS
12H-1191:08 in no’s awning supporting stanchions in bridge wing (Port and Stbd) corroded/deteriorated. To be renewed as per sample. Awning to be stitched. Mat Stanchion -ALAwning size- 200cm x 130cm
13H-1192:Ship’s galley wash basin drain pipe corroded. To be repaired/ renewed as per the sample. Mat-MS,
14H-1193;Ship’s galley FCU drain pipe tray corroded. Insulation, galley fresh water tap and non-return valve to be renewed as per the sample. Drain Pipe size - 1/2-inch and FUC pipe length - 1 Mtr.
15H-1199:Ship’s office, Regulating office, OPS room, Mso Metallic drawers channels not working properly. To be repaired/ renewal as per the sample. Qty-25 no’s lockers