Provn Of Iron Cage For Oh Water Tank Of Otm And Md Accn At 506 Abw And Spl Repair / Replacement Of Oh Lt Line To Lt Ug Cable In Ordnance Road At Cod Under Age B / R-Ii And Age E / M Of Ge ( East ) Jabalpur As Per Boq, jabalpur-Madhya Pradesh

Military Engineer Services-MES has published Provn Of Iron Cage For Oh Water Tank Of Otm And Md Accn At 506 Abw And Spl Repair / Replacement Of Oh Lt Line To Lt Ug Cable In Ordnance Road At Cod Under Age B / R-Ii And Age E / M Of Ge ( East ) Jabalpur As Per Boq. Submission Date for this Tender is 09-06-2022. Shelving and Storage Tenders in jabalpur Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32188265
Corrigendum : Provn Of Iron Cage For Oh Water Tank Of Otm And Md Accn At 506 Abw And Spl Repair / Replacement Of Oh Lt Line To Lt Ug Cable In Ordnance Road At Cod Under Age B / R-Ii And Age E / M Of Ge ( East ) Jabalpur As Per Boq
Open Tender
Indian
Madhya Pradesh
jabalpur
09-06-2022

Tender Details

Provn Of Iron Cage For Oh Water Tank Of Otm And Md Accn At 506 Abw And Spl Repair / Replacement Of Oh Lt Line To Lt Ug Cable In Ordnance Road At Cod Under Age B / R-Ii And Age E / M Of Ge ( East ) Jabalpur As Per Boq

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Jun-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-06-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 84000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : PROVN OF IRON CAGE FOR OH WATER TANK OF OTM AND MD ACCN AT 506 ABW AND SPL REPAIR/REPLACEMENT OF OH LT LINE TO LT UG CABLE IN ORDNANCE ROAD AT COD UNDER AGE B/R-II AND AGE E/M OF GE (EAST) JABALPUR
Sl. No. Item Description
1S&F rolled mild steel in framing for cladding glazing framing work or similar work including necessary cutting drilling welding etc fixed with angle cleatsand connecting plates confirmimg to FE 290 (GDE E-165) Complete all as specified.
2S&F weldedsteel wire fabric and fixed complete to steel members weights not exceeding 4 kg/Sqm Complete all as specified.
3Mild steel screw bolts (machine made) 5 mm to 10 mmwith hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long.
4M&L plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone agg) as in filling under undulation of roof top/chajja/beamincl necessary formwork complete all as specified and directed.
5S&F Butt hinges 75 mm size, medium weight, cold rolled mild steel.
6S&F M Shandles 100mm size, cast type, anodised.
7S&F M Sbarrel tower bolts 150mm long of extruded section.
8Cutting hole by drilling for fixing of boltsof fix the cage plate4 nos holeforcage by of the monkey cage and filling with epoxy grouting as per complete and matching with exiting surface all as specified and directed.
9Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately under relevant items here-in-before.
10Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc.
11M&L Preparation of new steel sufaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved shadeover one coat of red oxide primer not otherwise described including rubbing out and cleaning rust on new steel surfacesComplete all as specified and as directed by the Engineer-in-Charge.
12Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
13Taking up or down 25 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
14Taking up or down 40 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
15S&F 20 mm bore GI tubes, "medium grade" galvanised, with all fitting and fixed complete including cutting, chaising, pinning and making good to walls and ceiling or laid in floors.
16Refixing old 20 mm dia steel tubing including cleaing and connections with all fitting in new or old position (wall, ceilling, floor etc).
17S&F 25 mm boreGI tubes, "medium grade" galvanised, with all fitting and fixed complete including cutting, chaising, pinning and making good to walls and ceiling or laid in floors.
18Refixing old25 mm dia steel tubingincl cleaing and connections with all fitting in new or old position (wall, ceilling, floor etc).
19S&F 40 mm boreGI tubes, "medium grade" galvanised, with all fitting and fixed complete tincl cutting chaising pinning and making good to walls and ceiling or laid in floors.
20Refixing old40 mm dia steel tubingincl cleaing and connections with all fittingin new or old position (wall, ceilling, floor etc).
21S&F Ball valves 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe & fixed. (minimum weight 20mm-210 gms).
22S&F 20 mm diaGun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
23S&F 25mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
24S&F 40 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
25Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size120 sq mm 3.5 core Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE.
26Supply andlayingcable XLPE insulated screened PVC bedded, galvanisedsteel strip or wire, armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminiumconductor 95 Sqmm 3.5 core. Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE.
27Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size70 sq mm 3.5 core Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE.
28Supply andlayingcable XLPE insulated screened PVC bedded, galvanisedsteel strip or wire, armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor 50 Sqmm 3.5 core. Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE.
29Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 50 to 70 sqmm, Indoor/Outdoor type. Make:- Denson, M,seal,Raychem.
30Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 95 to 120 sqmm, Indoor/Outdoor type. Make:- Denson, M,seal,Raychem.
31Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out all as specified.
32Returning filling including spreading and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified.
33Removal of surplus/spoil on a distance n.exc 25 cm thick in soft loose soil all as specified.
34Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm laid in trenches for under ground cable all as specified.
35M&L for Sand cushioning trenches using fine sand to under ground cable, laid in two layers 15 cm before laying the cable & 8cm after laying the cable complete all as specified.
36M&L for cable protection GI tubinglight grade fixed long the pole/under road/along the wall of size 80 mm bore with necessary clamps all as directed.
37M&L for Earthing complete with galvanized steel earth plate electrods of size 60cm x 60cm x 6mm thick burried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to galvanised iron strip 32 x 6 mm as earthing lead by means of bolts nuts check nuts and GI washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No. 3 of SSR Part-I and connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and commansalt in alternate layers 25 mm dia light grade GI pipe, funnel, wire mesh. concrete 1:3:6 type C-1 for pit and RCC pit cover. PCC pit shall be provided 50 cm away from earth pit and not on the earth pit itself. The extra cost of the watering pipe, bends, elbows shall be included in the unit rate.Note : RCC pit cover shall be precast of RCC 1:2:4 type B-1 80mm thick reinforced with XPM weighing not less than 4 Kg/Sqm.
38Schedule of credit amount of Rs. 8,550.00to be deducted during AOC.