Repair Work At Police Station Bindapur New Delhi Repair Work At Police Station Bindapur New Delhi
BOQ
| Sl. No. | Item Description |
| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 2 | 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). |
| 3 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 4 | 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size) |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 6 | Mild steel and Medium Tensile steel bars |
| 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 8 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 9 | Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): |
| 10 | 18 mm thick |
| 11 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 12 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 13 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 14 | In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 15 | Providing and fixing Ist quality ceramic glazed wall riles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burggundy, bottle green, blck of any size as approved by Engineer-in-Charge, in shirting, risers of steps and dados, over 12 mm thick bed of cemnent mortar 1:3 (1 cement : 3 coarse sand) and joining with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 16 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 17 | Providing sand stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : |
| 18 | Red sand stone slab |
| 19 | 40 to 50 mm thick |
| 20 | 12 mm cement plaster of mix : |
| 21 | 1:4 (1 cement: 4 coarse sand) |
| 22 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. |
| 23 | Two or more coats on new work |
| 24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 25 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 26 | In mud mortar |
| 27 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 28 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 29 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 30 | W.C. pan with ISI marked white solid plastic seat and lid |
| 31 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 32 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 34 | Internal work - Exposed on wall |
| 35 | 20 mm nominal dia Pipes |
| 36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 37 | 32 mm nominal dia Pipes |
| 38 | 75 mm nominal inner dia Pipes |
| 39 | 100 mm nominal inner dia Pipes |
| 40 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 41 | External work |
| 42 | 15 mm dia nominal bore |
| 43 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 44 | 30 cm length |
| 45 | 15 mm nominal bore |
| 46 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 47 | 15 mm nominal bore |
| 48 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931: |
| 49 | 15mm nominal bore |
| 50 | Providing and fixing PTMT pillar cock of approved quality and colour. |
| 51 | 15 mm nominal bore, 107 mm long, weighing not less than 110 gms |
| 52 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 53 | Group A |
| 54 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 55 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 56 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 57 | (i)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 58 | (ii)2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 59 | Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 60 | i) 3 x 1.5 sq. mm |
| 61 | ii) 3 x 4 sq. mm |
| 62 | iii) 3 X 6 sq. mm |
| 63 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 64 | (i) 20 mm |
| 65 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 66 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 67 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 68 | Supplying and fixing call bell/buzzer suitable for DC/AC single phase 230 volts, complete as required as per the direction of engg -in- charges. |
| 69 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. |
| 70 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 71 | Supply, installation, testing and commissioning of 1200 mm (nominal size), 30 watt / 36 watt LED batten luminaire in aluminium housing with minimum light output 100 lumen/watt complete with all accessories, electronic driver,diffuser, directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.( Makes : Philips / GE/ Havells/ Wipro/ Crompton/Jaquar ) |
| 72 | Supply, installation, testing and commissioning of 12 Watt /15 Watt surface mountedLED downlighter luminairecomplete with all accessories and electronic driver, directly on ceiling / wall, including connections etc. as required. Makes : Philips / GE/ Havells/ Wipro/ Crompton/Jaquar) |
| 73 | Supply, installation, testing and commissioning ofwallmounted light fixture complete with B22 base, diffuser and15 watt LED blub etc as requireddirectly onwall, including connections etc. as required.(Approved Makes:- Havells City 3 Wall light /orequivalent model Philips / Wipro/ Crompton /Jaquar) |
| 74 | Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 75 | 6 Module |
| 76 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 77 | 10 Amp Modular switch |
| 78 | 20 Amp Modular switch |
| 79 | 3 pin 10 Amp socket outlet |
| 80 | 6 pin 20/25 Amp Socket outlet |
| 81 | Supplying and fixing PolycarbonateBattan/Angle holder with 8/10 watt LED bulbincluding connection etc. as required. |
| 82 | Supply, installation, testing and commissioning of 10 watt LED bulkhead fittings with IP 66 ingress protection complete with all accessories and electronic driver, etc as requireddirectly onwall, including connections etc. as required.Makes : Philips / CG/ Havells/ Wipro/ Crompton/Jaquar ) |
| 83 | Supply, installation, testing and commissioning of 300 mm (nominal size) 9/10 watt LED batten luminaire with minimum light output 100 lumen/watt complete with all accessories, electronic driver,diffuser, directly on ceiling/ wall, including connectionsetc. as required.( Approved Makes :- Wipro Garnet 10W LED Batten or equivalent model of Havells/ Crompton / Philpis / GE) |
| 84 | Supplying, Installation, testing and commissioning ofBEE 5 star rated, 1200 mm sweepceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. Makes :- Crompton /Havell\"s / Usha / Orient ) |
| 85 | Supplying and installation of 300 mm sweep, 1400 RPM heavy dutyexhaust fan complete with louvers/shutters in the existing opening, including making the hole to suit the size of the above fan and making good the damage, connection, testing, commissioning etc. as required.(Havells makeISI markHeavy Duty Exhaust Fan or with similar specifications Crompton/Havells / Orient / Usha / Almonard) |
| 86 | Supplying, installation, testing and commissioning of 30 W LED based Flood light luminaire,housing made up of pressure die cast aluminium / aluminium alloy, complete withdriver, cover andmountingbracket etc including installation directly onwall andconnection with 3 X1.5 sq.mm FRLS PVC insulated copper wire etc as required. The fixture should have a minimum system efficacy of 100 lumen/Watt, ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK >=05.The fixture driver should have an operating voltage range of 140-270 V, surge protection of >=3KV, PF >0.9 and THD<20%. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance.LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. (Approved Make: Phillips MODEL NO.BVP120 LED 35 CW FG S1 PSU GR OR similar in Schreder/ Lighting Science / GE/ Philips/ Jaquar ) |
| 87 | Supplying and installation of fresh air fanwith louver shutter 250 mm sweep in the existing opening including making the hole to suit the size of the above fan and making good the damage, connection, testing , commissioning etc as required.(Havells make Ventil Air-DX with self opening louvers or with similar specifications CG / Orient / Usha / Almonard/Havells ) |
| 88 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 89 | 12 way , Double door |
| 90 | Supplying and fixing 5 amps to 32 amps, 240 Volts \"C\" series MCB\"s suitable for lighting and other loads of following poles in the existing MCB DB complete with connection, testing and commissioning etc as reqd. . |
| 91 | a) Single Pole |
| 92 | b) Double Pole |
| 93 | Dismentling of old surface / recessed wiring and distribution board of 01 no Type - III qtr and making the damage good etc as required as per direction of engg.-in-charge. |
| 94 | Less for cost of dismental material retrieve from the Qtr/ buildings which will be kept by the contractor i.c Cu/Al conductor PVC insulated wire, switch box, PVC/MS conduit pipe, accessories, Old fans and other electrical fitments etc complete as reqd. |
AI Tender Summary
Tender Timeline
May 11, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedMay 18, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 20, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender