Internal Electrification Of New 20 Beded Covid Ward,Installation Of 30 Kva Dg Set And Supplying And Installation Of Fire Fighting System At New Covid Ward At Gorubathan Bphc.

Issued by Government Departments · gorubathan, West Bengal
Tender Value
24.62 Lakhs
Estimated cost
Bid Submission
21 May 2022
0 days left
EMD
49241
Bank guarantee accepted
Document Fee
2505
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
gorubathan → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Internal Electrification Of New 20 Beded Covid Ward,Installation Of 30 Kva Dg Set And Supplying And Installation Of Fire Fighting System At New Covid Ward At Gorubathan Bphc.

BOQ

Name of Work:Internal electrification of 20 beded covid ward,supplying and installation of 30 KVA DG set ,supplying and installation of fire fighting system at Gorubathan BPHC.Gorubathan Block ,Kalimpong.
Sl. No. Item Description
1Internal Electrification works:Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casing capping and Switch board both on surface](i) Average run 6 mtr
2(ii) Average run 8 mtr
3(iii) Average run 10 mtr
4Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping on surface and Switch board concealed] i) On Board
5Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required a) 2 x 22/0.3 (1.5 sqmm)
6s) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
7x) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
8Fixing only single/twin flourescent light fitting complete with all accessories directly on well/celling with HW block & suitable size MS fastener, ceiling plate, nipples etc as required.
9REGAL BATTEN FOR LED TUBE Universal batten for G13 T8 lamps. LHFYBYPNIA1W022
10REGAL BATTEN FOR LED TUBE Universal batten for G13 T8 lamps. LHFYBWP2TB1W020
11LED streetlight made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07.
12Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall ofthe building incl. making holes to building, S&F 40 mm dia GI pipe(ISI-Medium) 1.50 mts. average length, with GI socket at one endand thread at the other end & suitable bend to house the fitting &making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting
13Supplying Only 250 V A.C. Ceiling Fan (ES-NEO) White / Brown / Ivory of dia 1200mm Havells make.
14Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by (ii) 2x1.5 sqmm flexible copper wire
15Supplying only Ventilating Fan Ventil Air-DXR 150 mm, Havells make.
16Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: a) 23 cm (9\")
17Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
18Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works 25x10mm Size.
19Supplying and Fixing of multipal power point with all assories with necessari connection.
20Supplying only Electric call bell system includind indicator and necessary connection.
21Fixing only Call Bell/Buzzer on single HW board on wall incl. S&F single HW board
22Supply & Fixing 240 V, Modular socket (2 Module) type Fan Regulator (Step Type) (Brand approved by EIC) on existing Modular GI switch borad with top cover plate incl. making necy. connections etc.
23Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Legrand Make 2+4 Way)Legrand 2+12 way Enclosure (607712)
24Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand SP 6-32A MCB
25Supplying and fixing Sheet steel Main Switches on angle iron frame on wall
26Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Legrand Make 40 A DP) Legrand DP 40A MCB Isolator
27Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Legrand Make 100 A FP)
28Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode
29Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36cmX86.36cmX46cm deep (below ground level) complete with cemented brick work (1:6) of 25cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 35.56cmX35.56cm with locking arrangement, GI reducer including drilling of 46nos. 12mm dia. holes on the GI pipe.
30Extra for treatment of soil by using salt & charcoal or coke for plate electride (for soft soil / morrum soil)
31Supplying, fabrication and commissioning of L.T. Panel board with 16SWG MS sheet enclosure on MS Flat/ angle complete with fixing of TPN Switch Disconnector Fuse Unit, FP Changeover & 4 bar Busbar and making connection to equipments.(a) 5\" X 3\" = 15 sq.ft. @ Rs. 6000.00/sq.ft
32Three Phase Energy meter
3330 KVA DG set: Supplying, installation & commissioning of Kirloskar make 30 KVA Sound Attenuated Diesel Generator Set with AMF panel
34Supplying of the following 1.1 kV grade PVC insulated LT power cable aluminium conductor armoured cable as per IS- 7908 (Part 1) 1988, Havells make.a) 3.5 Core 50 sq.mm.
35Laying of cable as below, after cutting floor / pavement/wall/ and making holes incl. embeddingthe cable at an average depth as belowand mending good the damages to original finish incl. removing the rubbish. b ) Above 35 sqmm to 95 sqmm at an average depth of 100 mm infloor/pavement/wall etc.
36Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode
37Extra for providing masonary enclosure on the top of the earth electrode of overall size 86.36X86.36X46 cm. deep ( below ground level ) complete with cemented brick work ( 1:6) of 25 cm. width duly plastered with cement morter C.I. hinged inspection cover of size 36.56 X 35.56 cm. with locking arrangement, G.I. reducer including drilling of 46 no. 12mm. dia. holes on the G.I.Pipe.
38Extra for treatment of soil by using salt & charcoal or coke for plate electrode.
39Fire Fighting system,Fire hydrant parts:-a)Supplying and erection of Single headed hydrant valve (ISI marked)
40b) Supplying and erection of Signal house box metal
41c) Supplying onlyFirehouse with male female coupling
42d) Supplying and erection of short branch pipe with nozzle
43e) Supplying and erection of fire bridge inlet(2 ways)
44Main Fire Pump:- b) Supplying and installation of 10 HP electric motor driven jockey pump with working head of 45 mtrs or as required with all fittings and accessories of Kirloskar or equivalent make.
45Fire pump Control Panel Combined with all two pumps or combined with main fire pump and jockey pump with separate panel for diesel driven pump.(Depends upon the position and input power load of site)
46Piping with MSERW(Medium)pipes conforming TATA /Bansal/Jindal marked to IS:1239 (ISI marked)completed with all fittings,supports for paints of PO>Red shed. a) Supplying and erection of 150 NB size pipes with all fittings and necessary connectioncomplete including painting(red).
47b) Supplying and erection of 100 NB size pipes with all fittings and necessary connectioncomplete including painting(red).
48c) Supplying and erection of 80 NB size pipes with all fittings and necessary connectioncomplete including painting(red).
49Pipe Fittings Different sizes of nuts,bolts,flange,washers for gate valve socket,MS Releaser,one full roll of white gasket including labour cost etc.
50Valve Section:-Gate Valve a)Supplying and erection of Gate valve of size 150 NB with fittings,sockets etc.
51b)Supplying and installation of Gate valve of size 100 NB with fittings,sockets,nipple,connector, bends etc.
52c) Supplying and installation ofHigh loaded pressure gauge meter 10 kg/sq cm (Approved make)
53d) Supplying and installation of High loaded pressure switch(Approved make)
54e)Supplying and installation of High loaded pressure releaser of (Approved make).
55Installation of N-R Valve a)Supplying and installation of 100 NB,N-R Valve.
56b) Supplying and installation of 80 NB,N-R Valve
57c)Installation of Foot Valve
58Fire+C32:J41 safety branded house rell system fixed fire fighting water based system rolled on metal drum with all stranded fittings and ISI marked rubber hose pipe with PVC made shut up nozzle.
59Conventional Micro ProcessorMain Fire Alarm Control Panel complete with battery back up 18 devices/per zone. Capacity 2 Zone
60Conventional Photo Electric Smoke Dectector with base.
61Manual Call Point
62Hooter 35 DB
63Junction Box
64End connection module
65Cabling 2 x 1.5 sq.mm copper multi stranded wire in PVC condiut and other fittings
66Carbon-Di-Oxide type Fire Extinguisher, Complete with all necessary fittings, conforming to IS 2878 with ISI Marked of capacity 3 lts.
67ABC (Stored Pressure) type Fire Extinguisher, Complete with all necessary fittings, conforming to IS 13849 with ISI Marked of capacity 3 lts.
68Transportation (Fire fighting- 2.5%)

AI Tender Summary

OUR REF NO 32181663
AUTHORITY Government Departments
TENDER VALUE 24.62 Lakhs
LAST DATE 21-05-2022
Authority
Authority Name Gorkhaland Territorial Administration
Work Description Internal Electrification Of New 20 Beded Covid Ward,Installation Of 30 Kva Dg Set And Supplying And Installation Of Fire Fighting System At New Covid Ward At Gorubathan Bphc.
Basic Detail
Tender No 01 of 2022-23 (2nd call)
Bidding Type Tender
Location
City gorubathan
State West Bengal
Key Dates
Publish Date 11 May 2022
Submission Date 21 May 2022
Open Date 24 May 2022
Finance
Tender Value 24.62 Lakhs
Tender Fee 2505
EMD 49241
Exemption Not Available
Document List
a4e001d8-4085-4a5c-8e05-f523f3c34869.html
BOQ_741519.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 11, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
May 21, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 24, 2022

Bid Opening Date

Technical bids will be opened and evaluated.