| 1 | CIVIL WORK. |
| 2 | Dismantling of brick masonry works under 3.00 Mtr. Height, stacking the useful materials for re-use & removing the debris within 50M. Initial lead, including cost of all labour, T&P, sundries, scafolding etc. completein all respectexcluding GST as directed by the Engineer- in- charge. |
| 3 | Dismantling and removing of lime concrete flooring 7.5 cm to 10 cm thick including stacking the useful materials for reuse and removing the debris within 50m lead, conveying and depositing the materials away from the site, including cost of all labour, T&P, sundries etc completein all respectexcluding GST as directed by the Engineer- in- charge. |
| 4 | Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m leadconveying and depositing the materials away from the site, including cost of all labour, T&P, sundries etc completein all respectexcluding GST as directed by the Engineer- in- charge. |
| 5 | Earth work in excavation of foundation trenches in all kinds of soil within50m.Initial lead and 1.5m initial lift including rough dressingand breakingclods to maximum5cm to 7cm and laying in layers not exceeding 0.3m in depth and and depositing the excavated materials away from the work site with all lead and lift, including shoring, shuttering & dewatering (if required) with cost of alllabour, hire & running charges of thewater pumps, sundries, T & P required for the work complete excluding GST as directed by the Engineer- in- charge. |
| 6 | Providing and layingPlain Cement Concreteof proportion (1:3:6)infoundation and floors (i.e. below the base course of the flooring) using cement ,40 mm size crusher broken H.G Stone Metaland screened & washed sharpriver sand for mortar of approved quality & from approved quarry including hoisting, lowering and laying concrete to the required level, ramming, watering & curing etc complete to required levels, laid in layers not exceeeding 15cm thick in each layerincluding cost, conveyance , loading,unloading,royalties of all materials, cost of all labour, Sundries, T&Prequired for the work including shoring, shuttering and dewatering ( if required) including hire and running charges of water pumprequired for the worketc complete excluding GST in all respect as directed by the Engineer-in-charge. |
| 7 | Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25Grade inall type of Concrete works( i.efooting, Plinth Band, Lintels, Chajja, Shelf fins, Roof slabs, Balconies, Staircase, Column, Beam Parapets, Window sills, Lofts, Railings etc. )as per approved designs and drawings having a minimum compressive strength ( in work test) 25 N/mm2 in 15 cm. cubes at28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleanedto be mixed in concrete mixturewith approved quality of cementincluding hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, including cost of requiredsteelcentering and shuttering thereafter dismantling and removing thedebrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary |
| 8 | including cost, conveyance, loading, unloading,stacking, royaltiesof all materials, cost of all labours, scaffolding, sundries, T&P required for the work etc. completeinall respect butthe excluding cost &conveyanceof M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc.ofM.S. rods or Tor steel and binding wires and tying the grills and placing in proper position excluding GSTas directed by the Engineer-in-charge. |
| 9 | Providing & fixing Thermo mechanically treated bars (Fe-500 ) Reinforcement bars of approved makefor RCC work of required diameter& of approved quality including straightening, cutting, bending, binding, welding , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings with provision for fan hooks where required including the cost, conveyanceof reinforcement bars or tor steel and binding wires of 18 to 20 gauge, cost of all labour,loading, unloading, labour cess, T&P, etc. required for the work complete for the workin all heights as per the specification & excluding GST as direction of Engineer-in-Charge. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement. No payment will be made for overlap, couplings, welded joints spacer bars,stays, hangers and wastage. Cost of these items shall be deemed to be included in the rates for reinforcement) |
| 10 | Providing strong, rigid, leveled and plumbed centering and shuttering to required shape and size for all kinds of R.C.C. works in the items mentioned below with wooden or steel centering materials with all necessary bracing, ties and supports for level centering covered with bituminous paper including provision of necessary holes and pockets, electrical conduit pipe, P.H. pipes, fan hooks or boxes, switch board insert plates, clamps and extension bars etc., dismantling and removing the shuttering after the required interval from the date of casting (not less than 3 weeks) including the cost of all materials, cost of all labour, labour cess, conveyance,shoring, shuttering and dewatering, loading and unloading, sundries, T&P scaffolding, etc. completein all respectexcluding GST as directed by the Engineer- in- charge. |
| 11 | Foundation & plinth |
| 12 | Beam |
| 13 | Disposal of cleaning waste materials mixed with earth with Transportation by mechanical means with in 5km from the road side including cost of all labour,loading and un loading at site,T&P, sundries etc completein all respectexcluding GST as directed by the Engineer- in- charge. |
| 14 | Fly Ash. brick masonryof size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use ,including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the workscomplete in all respect excluding GST as directed by the Engineer-in-charge. |
| 15 | Foundation & plinth |
| 16 | Super structure |
| 17 | Supplying & Filling in foundation trenches and plinth, ditches with river sand well watered and rammed in layers not exceeding23 c.mindepthwith all lead and lift, including cost, conveyance, loading, unloading,stacking,royalties of all materials, cost of all labour, sundries, T&P required for the work etc. complete excluding GST in all respect as directed by the Engineer- in -charge. (Measurement will be taken on finished compacted section only) |
| 18 | Providing, fixing & laying of precast interlocking paver block of 60mm thick made out of M-35 grade concrete with minimum compressive strength of 35 N/sqmm at 28 days as per IS 15658: 2006 Clause 5 and 9.1.4 over 50mm thick bed of well compacted sand including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. completein all respectexcluding GST as directed by the Engineer- in- charge. |
| 19 | Providing Granite stone prepolished 20mm thick of areaabove 0.40 Sqm in flooring of approved quality, ccolour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if requiredwatering and curing for 21 days, including cost, conveyance, loading, unloading, royaltiesof all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically and wax polishing etc. complete in all respect excluding GST as directed by Engineer-in-charge(Note- Sample of tiles shall be approved before procurement and use.) |
| 20 | Providing , Fitting &Fixing16 mm thickKota stone tile (above.10sqm) inflooring using specialgradeof Kota stone tileconfirming to I.S 13755 of approved quality and shadein floors, treads on steps and landings in all floors at all height on 20 m.m thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened & washed sharp riversand for mortar andgrouted with neat white cement slurry, joining the kota stonetilewith neat white cement slurry, including cost, conveyance, loading, unloading, stacking, royaltiesof all Materials, cost of all Labour, Sundries, T&P required for the work, Watering , Curing for requireddays , cleaningthe flooring space manually etc. complete in all respectexcluding GST as directed by the Engineer-in-Charge. |
| 21 | Providing & Fixing tiles of size20 x 30cmglazed ceramic wall tiles of premium grade of approved quality and shade having thickness 8mm to 10mm confirming to IS 13755in dados skirting and risers of steps on 12mm thick cement plaster (1:3) to proper slope, line and level including cutting to required size and shape, fixing at corners and splays etc including filling thejoints with neat whitecement slurry mixed with pigments to match the shade of the tilesincluding cost, conveyance,loading,unloading,stacking, royalities of all materials, cost of all labour,T&P, sundries, watering and curing for the required period for the work complete in all respect excluding GSTas directed by Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.) |
| 22 | Providing and fixing colour coated galvanized steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self-drilling/ self-tapping screws complete: Ridges plain (500 - 600mm) and cost, coveyance, loading , unloading of all Materials, cost of all Labour, Sundries ,Scafffolding ,Stagingand T&P etc. required for the work completein all respectexcluding GST as directed by the Engineer- in- charge. |
| 23 | Supply and fixing of Mikasa Pristine (Wooden Flooring), Plank Thickness 15 mm, Top Layer 3 mm Veneer/Hardwood, Middle Layer 10 mm Pine Wood having Density 650 kg/m3, Bottom Layer 2 mm Balancing Veneer, Plank Size (1800 to 2400mm X 135 to 210)mm, 1,2 & 3 Stip,Natural/ Stained/ Smoked, Satin lacquered/ Matt lacquered/ Brushed, Square Edge/ Micro-Bevelled Edge/Bevelled Edge, PlankLok Joint, Glueless Installation, Prefinished Surface with 7 times UV hardened acrylic lacquered, free from formaldehyde emission as strictly following EU E1 norms, Resanding and Refinishing 2 times after 10 years interval, Moisture Content 7-9%, Free of insects, woodworms as secured by process temperatures, Fire Class G, highest Fire classification as per Swedish Building Code BBR 94,on top of 2mm moisture barrier and a substrate of smoothly finished cement and sand plastered surface with cement slurry coating including wastage, as per approved specification including cost, coveyance, loading , unloading ,stackingof all Materials, cost of all Labour, Sundries ,Scafffolding ,Stagingand T&P etc. required for the work completein all respectexcluding GST as directed by the Engineer- in- charge. |
| 24 | Providing and fixing 12 mm thick frameless toughfened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting Hydraulic Floor Spring type fixing arrangement and making necessary holes etc. for fixing required door fittings,all complete as per direction of Engineer-in-Charge (Excluding GST) The edges will be high polish all the side with cutting hole for top patch, bottom patch. (The patch fitting- Godrej make L connect patch- Godrej make - Code -5755, SS 304 grade pull handed D type -25x300 mm -code - 2802 with high quality Floor spring make -Godrej -B-710-80kg- Code-8341 as per ISI certification. The price including of lifting of glass to 3rd floor, transportation and installation (Sample of all materials with make/ brand should be approved before precurement and use in work). |
| 25 | Supplying, Diluting &SpreadingChemical Emulsion like CHLORPYRIPHOSOROther Chemical approved bythe Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional anti- termite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floorsalong with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) completeincludingcost, conveyance, loading, unloading and taxes of all materials,cost of all labour, T&P, sundries and scaffoldingwhere required for the work etc. complete in all respect as per specificationas directed by the Engineer -in -charge. |
| 26 | a) Treatment to soil below raft: Before laying the rubble soling and pcc the compacted and leveled soil shall be treated at 5 litre / sq.m. |
| 27 | b)Treatment to soil along the retaining wall:The soil coming in contact with the retaining wall shall be treated at 5 litre per sq. m. The treatment shall follow the backfilling as backfilling is done in stages of 30 cms but not to exceed a depth of 1metre. Rodding may be carried out to facilitate the treatment. |
| 28 | c)Treatment to soil along the external perimeter of the building:The soil around the external perimeter of the building up to a depth of 30 cm shall be treated at 2.25 litres per linear metre. Rodding may be carried out to facilitate this treatment. |
| 29 | d) Treatment of soil surrounding pipes, wastes and conduits:When pipes, wastes and conduits enter the soil inside the area of the foundation, the soil surrounding the point of entry must be loosened around each such pipe, waste or conduit for a distance of 15 cm and upto a depth of 7.5cm and loosened soil shall be treated with chemical emulsion. |
| 30 | e)Spraying equipment:A pressure pump shall be used to carry out spraying operations to facilitate proper distribution of chemical in the soil. |
| 31 | Note: All the Anti-termite treatment shall be executed through a recognisedagency approved by the Engineer-in-charge. A written guarantee on non-judicial stamp paper shall be submitted by the Contractor for a minimum period of 10( ten ) years from the certified date of completion for the satisfactory performance of the entire Anti-termite treatment system. The Defect Liability Period of the Anti-termite treatment is Five years.The contractor has to furnish bank guarantee amounting toRs 7,500/- which will be released after10(ten) years from the date of completion of the whole work. In case,the contactor fails to furnish the B.G.,equalamont i.e. Rs 7,500/- will be kept withheld from the Security Deposit till the end of the Defect Liability Period. |
| 32 | 12 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all heightusingscreened &washed sharp river sand for mortar with approved quality of cement, finished smooth to the even surface ofthe brick masonry walls after racking out the joints properly ,providing grooves wherever necessaryincludingcost, conveyance, loading, unloading,stacking, royaltiesof all Materials,cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc.required for the workcomplete in all respect excluding GST as directed by the Engineer- in- charge. |
| 33 | 16 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all heightusingscreened &washed sharp river sand for mortar with approved quality of cement, finished smooth to the even surface ofthe brick masonry walls after racking out the joints properly ,providing grooves wherever necessaryincludingcost, conveyance, loading, unloading,stacking, royaltiesof all Materials,cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc.required for the workcomplete in all respect excluding GST as directed by the Engineer- in- charge. |
| 34 | Painting2 (Two) or morecoats with Weather CoatPaint of premium brand Such as Asian/ Berger/ ICI paints or equivalent of approved quality & colour, using required quantities of paint as specified by the manufacturer to give an even shade over a coat ofwall priming(water based)on the finished externalplastered surfaceat all height , watering the surface before applying theWeather CoatPaint and curing for the required periodincluding cost, coveyance, loading , unloading ,stacking andall taxes , cost of all Labour, Labour cess, Sundries ,Scafffolding ,Stagingand T&P etc. required for the work complete in all respect as directed by the Engineer-in-charge. |
| 35 | Providing suplying ,instaling,fixing and fitting the gallery chair with all material including all charges and taxes etc as per direction of EIC |
| 36 | Auditorium Chair, Push Back, PU Foam, PU Arm, Fabric, Tepestry, of size 550(L) X 660(D) X 965(H) (Model AUDI1) |
| 37 | Conference Table, Particle board and MDF top of size W1500 X D750 X H750 (Model CONFERENCE 8) |
| 38 | Water ponding for minimum 48 hours and 50mm height shall be done to observe weak points in the concrete. Providing cementitious based injection grouting at construction joints, leaking spots and honey combs with 40 psi pump using Cebex 100 @ 225gms of Fosroc Chemicalsmixed to 50 kg bag of cement including joints packing using polymer modified mortar. Fixing of nozzles and chipped portions of nozzles shall be reinstated using Renderoc Plug of Fosroc Chemicalsas per manufacturer\"s specification |
| 39 | Surface Preparation : |
| 40 | The cleaning and preparation of the substrate to which waterproofing barrier is applied must be carried out thoroughly to leave a sound base for the application. Any laitance present on the surface must be removed mechanically. Release oil and other contaminants which may impair adhesion must be removed prior to the application. Surface shall be maintained in SSD condition before applying waterproof coating. |
| 41 | Coving at Right Angle Junctions : |
| 42 | All the right angle junctions between floor and wall shall be provided with coving of size 75mm x 75mm minimum 15mm thickness in cement mortar 1:4 admixed with Nitobond SBR of Fosroc Chemicals@ 2 litres per 50 kg bag of cement after saturating the surface with water and applying a slurry primer coat with Nitobond SBR. |
| 43 | Down Take Pipe Packing : |
| 44 | The pipes to be fixed should be filed in order to provided a proper bond and the same to be alligned by the respective agency. The annular space around the drain pipe shall be packed using Conbextra GP2 of Fosroc Chemicals , a high strength free flow non shrink grout mixed water in ratio 0.16 The surface shall be suitably prepared using wire brush, primed with Nitobond SBR on the core surface fixing leak free form work as per manufacturer\"s specification. |
| 45 | Waterproof coating : |
| 46 | Providing and applying waterproof coating using Nitoproof 725 One-component cold-applied water based modified polyurethane hybrid elastomeric waterproof membrane of Fosroc Chemicalsat minimum 0.8mm dft. in one coat having Solids by Volume : 62% , Tensile strength ASTM D412 : 1.75MPa , Elongation, ASTM D412 : >350% , Tear strength, ASTM D624 : 13N/mm , Adhesion to substrate : 1.9MPa concrete, Crack bridging, static/dynamic : 2mm ASTM C836 , Resistance to water : 10mpressure & SRI value 106 for whiteto be used on the Roof including parapet wall surface as per manufacturer direction. |
| 47 | Auditorium roof, octagonal roof, Hexagonal room, Office, baside room |
| 48 | PH Portion of works : |
| 49 | Supplying all labour, T&P and earth work in excavation in all kinds of soil in pipe trenchs etc including dressing and levelling the bed and depositing the soil within 50M initial lead and 1.5M initial lift, as per the direction of the Engineer-in-charge. |
| 50 | Filling foundation trenches and Plinth with excavated & selected earth, laying in layers not exceeding 23cm thick well watered & rammed etc. complete including labour, T&P, lead & lift cost & conveyance, loading, unloading etc. complete as per specification & direction of EIC. |
| 51 | Filling the sand encasing all around the PVC pipe :including supply of all material, labour, T&P etc all copmlete. |
| 52 | Supplying all materials, labour, taxes for fitting and fixing of uPVC Schedule-80 pipes of 100% lead free conforming to ASTM D-1785 including fitting conforming to ASTM D-2467 of following nominal size including earth work in excavation in all kinds of soil, laying in trenches over a bed of sand layer including testing the pipe line and back filling the trenches with selected earth as per the direction of Engineer in-charge. Make: ASTRAL/ASHIRBAD/EQUIVALENT. |
| 53 | 40mm (NB) Dia Pipe:- |
| 54 | 25mm (NB) Dia Pipe:- |
| 55 | 15mm (NB) Dia Pipe:- |
| 56 | Supplying all materials, labour, taxes for fitting and fixing of CPVC Ball valves confirming to IS codein all floor & fixing with the pipes after cutting the pipes to required shape & size including wastage etc .Of following nominal diameter , all complete icluding testing the joints with requred water pressure . The cost inclusive of all duties , transportation , scafolding etc . All complete as per the direction of Engineer in-charge. Make: ASTRAL/ASHIRBAD/EQUIVALENT. |
| 57 | 25mm ball valve |
| 58 | 40mm dia ball valve |
| 59 | Supplying all materials, labour & T&P for fitting and fixing of Flat back urinal. Make: jauare -URS-WHT-13261 |
| 60 | Providing all materials, labour and T&P for fixing of C.P FLUSH Cocks with adjustable wall flange. (Make-Jaquare of Cat no: FLV-1085 N ) |
| 61 | Providing all materials, labour and T&P for fixing of C.P Angle stop Cock with wall flange.(Make-Jaquare of Cat no:CON-053 KN) |
| 62 | Providing all materials, labour and T&P for fixing of CP Long Body Bib Cocks with wall Flange (Make-Jaquar cat no- CON-107KN) |
| 63 | Providing all materials, labour and T&P for fixing of C.P Pillar cock . (Make-Jaquare of Cat no: CON-021 KN) |
| 64 | Providing all materials, labour and T&P for fixing of CP2 wayBib Cocks with wall Flange (Make-Jaquar cat no- CON-041KN) |
| 65 | Providing all materials, labour and T&P for fixing of O.H. Shower with Shower Arm & Wall Flange. (Make-Jaquare of Cat no: OHS-1709) |
| 66 | Supplying all materials, labour & T&P for fitting and fixing of white glazed vitreous china HALF PEDESTAL WALL HUNG wash hand Basin. Make:JAQUARE (CNS-WHT-305+CNS-WHT-801) |
| 67 | Fixing 600mm x 450mm bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with chromium plated brass screws and washers complete as per specification.(Make:Saint Gobain)SR 3.4.26 |
| 68 | Providing all materials, labour and T&P for fixing of CP soap dish Holder.(MAKE-Jaquare of Cat no:ACN-1131N ) |
| 69 | Providing all materials, labour and T&P for fixing of CP Towel rail (Make-Jaquare of Cat no:ACN-1111SM ) |
| 70 | Providing all materials, labour and T&P for fixing of CP Towel ring (Make-Jaquare of Cat no:ACN-1121N ) |
| 71 | Providing all materials, labour and T&P for fixing of Double Robe hook. (Make:jaquare of cat no: ACN-1171N |
| 72 | Providing all materials, labour and T&P for fixing of C.P Glass -shelf .(Make Jaquare of Cat no: ACN-1171N). |
| 73 | Health Faucet ABS SS braided hose with 1.00m with CP hook (Make-Jaquare of Cat no:ALD-579 ). |
| 74 | Supply all material , labour, T&P for installation and commissioning of popup sprinklers capable of covering 12m at 3kg/sqcm pressure discharge rate of 0.18lps having SS retracts springincluding service saddle and popup shield made of heavy duty and UV resistant plastic as per specification & direction of EIC |
| 75 | Electrical Installation : |
| 76 | Wiring to Light, Ceiling Fan and 5 A Plug Points with 1.5-sqmm PVC Insulated 1100 Volt Grade Multi-Stranded Copper Conductor Wire for Phase, Neutral & Earth Continuity conductor and Loop Earth to Fitting & Fixture run inside 2mm thick PVC Conduit Pipe Recessed in Wall/ Column/Ceiling of the Building including Supply of Materials such as Clip-In Modular Type Switches of Legrand make (Myrius), Sockets, Modular PVC Switch Boxes, Cover, FRLS (Fire Retardant Low Smoke) Wire, Ceiling Rose, Angle / Batten Holder,Junction Box etc. complete with making good the damages caused as required and as per the direction of EIC. |
| 77 | Single Light Point Controlled by One 6A Switch or First Light Point of Group Control. |
| 78 | Ceiling Fan Point Based |
| 79 | Supply, Delivery, Installation and Testing of following types LED Fixtures directly on Wall/Ceiling of Building with all accessories such as Electronics Driver, Stove Enamelled Box, Perpex Sheet Cover etc. complete assembly including Supply and Fixing of PVC Round/Square Box & Making Connection from the suitable point outlet as per the direction of EIC. |
| 80 | Supply, Delivery, Installation, Testing and Commissioning of 100W Flood Light. |
| 81 | Supply, Delivery, Installation, Testing and Commissioning of 35W Gate Light. |
| 82 | Supply, Delivery, Installation, Testing and Commissioning Bollard 11Watt LED Type. |
| 83 | Supply, Delivery, Installation, Testing and Commissioning of 20W LED Tube Light. |
| 84 | Supply, Delivery, Installation, Testing and Commissioning 9W LED Lamp. |
| 85 | Supply, Delivery, Installation, Testing and Commissioning 60W LED Post Top Light with 10Ft Long &3\" GI Pole. |
| 86 | Supply, Delivery, Installation, Testing and Commissioning 3W LED Step Light (At Conference Hall). |
| 87 | Supply, Delivery, Installation, Testing and Commissioning of 40W LED 2.5mtr Dia Centre Light. |
| 88 | Supply, Delivery, Installation, Testing and Commissioning 10WLED Spot Light. |
| 89 | Supply, Delivery, Installation, Testing and Commissioning 10W LED Bulk Head Fitting. |
| 90 | Supply, Delivery, Installation, Testing and Commissioning of GI Pipe Earthing complete with 3 mtr x 40-mm dia GI Perforated Earth Electrode complete with required Charcoal, Salt, Inspection Chamber and Cover complete etc. as required Technical Specification and as per the direction of EIC. |
| 91 | Supply, Fixing and Laying of following GI Flat for Earth Connection to all Electrical Equipments and Iron Parts as required Technical Specification and as per the direction of EIC. |
| 92 | 25 x 5mm GI Flat |
| 93 | Replacing of 32A SP Rotary Switch |
| 94 | Supply, Laying and Testing of following size of XLPE Insulated, PVC Sheathed, CopperConductor Power Cable of 1100 Volt Grade laid directly Underground with Sand Cushioning, Brick Protection, Clamped on Surface of Wall/Column/Existing GI Pipe/Hume Pipe/PVC Pipe inside Masonry Cable Trench/On the Cable Trey as the case may be including cost of Saddles/Clamps/Cable Markers etc. but excluding the cost of GI Pipe/Hume Pipe/PVC Pipe compete with making good the damages caused as required and as per the direction of EIC. |
| 95 | 3 core X 4sqmmCopper Flexible Cable |
| 96 | Wiring for Circuits and Submain with following number & sizes of PVC Insulated 1100 Volt Grade Multi-stranded Copper Conductor Wire run inside 2mm thick PVC Conduit Pipe Recessed in Ceiling/Column/ Walls of Building including supply of all materials such as Wires, Conduit, Junction Box & Pull Box etc. complete with making good the damages caused as required and as per the direction of EIC. |
| 97 | 3 numbers Single Core 2.5 sqmm Copper Wire for Phase and Neutral Earth Continuity Conductor |
| 98 | 2 numbers Single Core 4 sqmm Copper Wire for Phase, Neutral and 1 number Single Core 4.0 sqmm Copper Wire for Earth Continuity Conductor |
| 99 | Supply, Installation and Testing of L.T. Outdoor/Indoor Wall/ Floor Mounted type Distribution Boards made out of 2mm / 1.6mm thick CR Sheet Metal Cubicle, duly acid treated for derusting, primered and painted with 2 coats of Enamel Paint of Approved Shade, Dust, Damp And Vermin Proof; having Hinged Door and Compartmental Arrangementfor eachequipmentand Busbar Chamber onthe top of the panel running horizontally; having provision for Cable/Conduit Entry, Earthing Studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of EIC. |
| 100 | Incoming: 1 No. 160-A25 KA MCCB |
| 101 | Outgoing : 4 Nos. 63A4P MCB, 3 Nos. 40AMP 4P MCB, 4 Nos. 25A DP MCB |
| 102 | 18W Fountain Light with Motor Repair and New Starter |