Providing And Installing Tubewell Of 150Mm I / D Straight Upto 170 Mtr. Depth , Tubewell In Place Of Failed Tubewell In Rural Drinking Water Supply Scheme Village Paharipur , Block Bhunerheri, District Patiala. , Patiala-Punjab

Water Supply And Sanitation Department-WSSD has published Providing And Installing Tubewell Of 150Mm I / D Straight Upto 170 Mtr. Depth , Tubewell In Place Of Failed Tubewell In Rural Drinking Water Supply Scheme Village Paharipur , Block Bhunerheri, District Patiala. . Submission Date for this Tender is 26-05-2022. Tube Well Tenders in Patiala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

32161822
Providing And Installing Tubewell Of 150Mm I / D Straight Upto 170 Mtr. Depth , Tubewell In Place Of Failed Tubewell In Rural Drinking Water Supply Scheme Village Paharipur , Block Bhunerheri, District Patiala.
Open Tender
Indian
Punjab
Patiala
26-05-2022

Tender Details

Providing And Installing Tubewell Of 150Mm I / D Straight Upto 170 Mtr. Depth , Tubewell In Place Of Failed Tubewell In Rural Drinking Water Supply Scheme Village Paharipur , Block Bhunerheri, District Patiala.

Key Value

Document Fees
INR 1000 /-
EMD
INR 18896.0 /-
Tender Value
INR 9.44 Lakhs /-

BOQ Items

Name of Work:DNIT for Providing & Installing Tubewell of 150mmi/dstraight upto 170 mtr. depth ,Tubewell in place of failed tubewell in rural drinking water supply scheme village PAHARIPUR , Block Bhunerheri, District Patiala.
Sl. No. Item Description
1Drilling of 500mm dia bore with Reverse Rotary Rig in all kinds of soil including the cost of consumable sores, fuel, oil and transportation of Rig to the site. Complete in all respects.
2Drilling of 500mm dia bore with Reverse Rotary Rig upto 150m Depth BGL.
3Drilling of 500mm dia bore with Reverse Rotary Rig from 150m Depth upto 300mtr.
4Supplying & lowering MS Pipe as per IS 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strenght to lower the pipe into tubewell bore. Weight 33.6kg per mtr.
5150mm nominal diametero/d 5.40 mm thickness (weight 21.6kg)
6Supplying, lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest with SS socket to connect Strainer to Strainer Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore
7150mm i/d5.00 mm thickness(Slot size 0.75)
8Supplying & fixing and lowering strainless steel socket as per IS 8110-2000 or latest, ISI Marked duly welded with suitable garde SS Welding electrode to lower strainer into tubewell bore complete in all respect.
9150mm internal diameter
10Supplying, lowering & fixing of MS Special socket to connect SS Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respects. 150MM I/D
11Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
12Supplying and fixing M.S well cap having thread to fix on housing pipe complete in all respect
13150 mminternal diameter
14Collection of Water sample from different strata and testing of sample from approved laboratory (physical & chemical Analysis)
15Supplying & fixing of bail plug of M.S. pipe complete with inverted U-hook attached to the bottom plug complete in all respect.
16150mm internal diameter (weight 21.6kg p/mtr)5.40mm thickness.
17Supplying & fixing of M.S. Clamp of size 150mm x 12mm made out of MS Flat 1.52 m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
18Making electric Logging of borehole with electronic well logger including cost of equipment at site etc.complete in all respect
19Supplying & fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects.
20Supplying at site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipe assembly and the bore. The gravel should be free from, dust, dirt, or the vegetable manner as per IS 4097/1967 with latest amendments
21Development of stabilizing of the tube well with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
22Capacity of Air compressor 300 cfm at 250 PSI
23Development of stabilizing of the tube well with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
24Sanitary seal in Gravel pack.
25Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide Uranium etc.)
26Load Tibha sand
27P/F Clay Seal
28Provision of sterilization of well on completion of tubewell as per BIS:2800:2019
29Providing & Installing Testing & Commissioning of one No. Electrically driven Submersible Pumping set of (Reputed make) capable of delivering 133LPM against a head of 90mtrcomplete in all respects as per specifications.
30PITC Electric control panel Complete as per specifications
31PITC of 2.50 mm2 size incoming cable complete as per specifications to pump chamber
32PITC of 2.50 mm2 size outgoing cable complete as per specifications to pump chamber
33PITC of Double Flanged MS Column Pipe of 50mm i/d size approximately 3 mtr long pieces 60 mtr including specials ISI marked (Medium Class) installing complete as per specification
34Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, V-Notch for V Notch houdi, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects as Annexure A12 – 2 & Drawings D-12 & D-17.
35Credit of old Material
36Providing, Laying fixing & Jointing of P.V.C. as per ISI:4985 (ISI Marked) with the prior approval of Engineer-in-Charge)along the trenches and laying the same in trenches to correct alignment and gradient,cutting jointing and testing complete as per specifications
37110 o/d PVC Pipe 10kg/cm2
38Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
39100mm i/d
40Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health departmentsize 0.6m x 0.6m
41Providing, installing, testing & commissioning of one No. Electronically actuated, Diaphragm Operated, Metering system, Chemical Doshing Chlorinator, suitabel for delivering 0.5 to 6 Liters of Bleaching Powder Solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 kg.cm2, and suction lift not less then 1.5, as per DWSS standard specifications.