}

Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engineering Department Of Rajiv Gandhi Institute Of Technology, Kottayam. Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engine, Kottayam-Kerala

Rajiv Gandhi Institute of Technology has published Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engineering Department Of Rajiv Gandhi Institute Of Technology, Kottayam. Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engine. Submission Date for this Tender is 26-05-2022. Laboratory Equipment Tenders in Kottayam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

32158606
Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engineering Department Of Rajiv Gandhi Institute Of Technology, Kottayam. Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engine
Open Tender
Indian
Kerala
Kottayam
26-05-2022

Tender Details

Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engineering Department Of Rajiv Gandhi Institute Of Technology, Kottayam. Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engineering Department Of Rajiv Gandhi Institute Of Technology, Kottayam. , Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architectureengineering Department , Temperature Humidity Meter Specifications Display: 3 1 / 2 Digit Lcd Range: -50 C~1300 C Resolution: 1º C Accuracy: ± 2 C~ -50 C To 0 C Battery: Standard 9 V Battery ( Neda 1604, Iec 6F22 ) , Solar Power Meter Specifications Display 3½ Digits, 2000 Readings Range 2000 W / M2, 634 Btu / ( Ft2xh ) Resolution 0.1 W / M2, 0.1 Btu / ( Ft2xh ) Sampling Time 0.25 Second Power Supply: 9 V Battery X1 , Globe Thermometer For The Measurement Of Radiant Heat Specifications Thermocouple Type K Measuring Range: 0 To + 120 O C , Digital Vane Anemometer 4 Digit Lcd Backlight Display. - Max - Hold Function. Measurement Units : Knots, Mph, Km / H, M / S, Ft / Min. Memory Of Maximum, Minimum And Average Record For Both Temperature And Wind Speed — Air Velocity Average Reading Upto 8 Multiple Points. — Auto Power Off Function — 2 Meters Coiled Cable Operating Temperature Meter :0°C To 50°C ( 32° F ~122° F ) , < 75 % Relative Humidity Vane : 0°C To 60°C ( 32° F ~140° F ) , Storage Temperature: - 20°C To 55°C At < 80 % Relative Humidity , Hotwire Thermal Anemometer With Temperature Measurement 0-500 C , Thermal Imager Ir Resolution ( Fpa Size ) 160 X 120 Epa Spectral Band 7.5?M To 14 ?M ( Long Wave ) Netd ( Thermal Sensitivity ) < Or= 0.08°C At 30°C Target Temp ( 80 Mk ) Fov ( Field Of View ) 22.5°H X 31°V Ifov ( Spatial Resolution ) 3.39 Mrad Ir Fusion Technology Pip ( 1.2 M ( 4 Ft ) To 4.6 M ( 15 Ft ) ) , Full Ir, Full Visible Minimum Ir Focus Distance 122 Cm ( 48 In ) Battery ( Field-Replaceable, Rechargeable ) Memory Storage Minimum 2 Gb Sd Memory Card , Sound Source Sound Power Level: 0 To 118 Db Re 1 Pw, Mains Operated 0 To 115 Db Re 1 Pw. Battery Operated Variable Attenuation From 0 To —40 Db In 10 Db Steps. Sound Power Spectrum :Wide Band: 100 Hz To 4 Khz +0 Db To —10 Db Re: Max. Level 63 Hz To 10 Khz, +0 Db To —30 Db Re: Max. Level Spectrum L: Fulfills Astm E 597 Spectrum Ii:Fulfills Astm E 597 Overload Indication: Indicates Max. Sound Power Level ( Overload ) And —3 Db Re Overload Pink Noise Output: ( To External Fitter Input ) : Pink Noise From 50 Hz To 10 Khz: 0.7 V Rms. Max. Load: 500 Ohm

Key Value

Document Fees
INR 2301 /-
EMD
INR 6720.0 /-
Tender Value
INR 6.72 Lakhs /-

BOQ Items

Name of Work:Supply of Various Lab Equipments for the use of Building science Lab I in ArchitectureEngineering Department
Sl. No. Item Description
1Supply of Various Lab Equipments for the use of Building science Lab I in ArchitectureEngineering Department
2Temperature humidity meter Specifications Display: 3 1/2 Digit LCD Range: -50 C~1300 C Resolution: 1º C Accuracy: ± 2 C~ -50 C to 0 C Battery: Standard 9 V battery( NEDA 1604, IEC 6F22)
3Solar power meter Specifications Display 3½ digits, 2000 readings Range 2000 W/m2, 634 BTU / (ft2xh) Resolution 0.1 W/m2, 0.1 BTU/ (ft2xh) Sampling time 0.25 second Power supply: 9 V battery x1
4Globe thermometer for the measurement of radiant heat Specifications Thermocouple type K Measuring range: 0 to + 120 o c
5Digital vane Anemometer 4 Digit LCD Backlight Display. - MAX - HOLD function. Measurement Units : knots, mph, Km/h, m/s, ft/min. Memory of maximum, minimum and average record for both temperature and wind speed — Air velocity average reading upto 8 multiple points. — Auto power off function — 2 meters coiled cable Operating Temperature Meter :0°C to 50°C (32° F ~122° F), < 75 % relative humidity Vane : 0°C to 60°C (32° F ~140° F), Storage Temperature: - 20°C to 55°C at < 80 % relative humidity
6Hotwire thermal anemometer with temperature measurement 0-500 C
7Thermal imager IR resolution (FPA size) 160 x 120 EPA Spectral band 7.5µm to 14 µm (long wave) NETD (Thermal sensitivity)< or= 0.08°C at 30°C target temp (80 mK) FOV(Field of view)22.5°H x 31°V IFOV (Spatial resolution) 3.39 mRad IR Fusion technology PIP (1.2 m (4 ft) to 4.6 m (15 ft)), FULL IR, FULL VISIBLE Minimum IR focus distance 122 cm (48 in) Battery (field-replaceable, rechargeable) Memory storage minimum 2 GB SD memory card
8Sound source SOUND POWER LEVEL: 0 to 118 dB re 1 pW, mains operated 0 to 115 dB re 1 pW. battery operated Variable attenuation from 0 to —40 dB in 10 dB steps. SOUND POWER SPECTRUM :Wide band: 100 Hz to 4 kHz +0 dB to —10 dB re: max. level 63 Hz to 10 kHz, +0 dB to —30 dB re: max. level Spectrum l: Fulfills ASTM E 597 Spectrum II:Fulfills ASTM E 597 OVERLOAD INDICATION: Indicates max. sound power level (overload) and —3 dB re overload PINK NOISE OUTPUT: (to external fitter input): Pink Noise from 50 Hz to 10 kHz: 0.7 V RMS. Max. Load: 500 Ohm
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail