| 1 | Supply and Erectionof 13 mtr Long ST Pole (ST-410SP-69) with base plate and top capincluding excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard |
| 2 | Erectionof 13 mtr Long ST Pole (ST-410SP-69) with base plate and top capincluding excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard (ST pole to be supplied by deparment) |
| 3 | Supply and Erectionof 11mtr Long ST Pole (ST-410SP-56) with base plate and top capincluding excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard |
| 4 | Erectionof 11 mtr Long ST Pole (ST-410SP-56) with base plate and top capincluding excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard (ST pole to be supplied by deparment) |
| 5 | Supply and Erectionof 9mtr Long ST Pole (ST-410SP-33) with base plate and top capincluding excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard |
| 6 | Erectionof 9 mtr Long ST Pole (ST-410SP-33) with base plate and top capincluding excavation of pit and back filling by boulders upto 1ft (as per latest specification and drawings adopted and approved by the department) as per REC construction Standard (ST pole to be supplied by deparment) |
| 7 | Dismantling of 13 mtr Long ST Pole (ST-410SP-69) with allied accessies: |
| 8 | Dismantling of 11mtr Long ST Pole (ST-410SP-56) with allied accessies: |
| 9 | Dismantling of 9mtr Long ST Pole (ST-410SP-33) with allied accessies: |
| 10 | Dismantling of wooden poles of different sizes complete with allied accessies: |
| 11 | Straightening of existing tilted 13 mtr Long ST Pole |
| 12 | Straightening of existing tilted 11 mtr Long ST Pole |
| 13 | Straightening of existing tilted 9mtr Long ST Pole |
| 14 | Straightening of existing tilted DW Wooden Pole |
| 15 | Providing and Painting of 13mtr Long S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade |
| 16 | Providing and Painting of 11mtr Long S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade |
| 17 | Providing and Painting of 9mtr Long S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade |
| 18 | Painting of 13mtr Long S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade |
| 19 | Painting of 11mtr Long S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade |
| 20 | Painting of 9mtr Long S.T Poles including fixtures with one coat of red-oxide and two coats of silver(aluminium) paint to give even shade |
| 21 | Providingand laying of Cement bottoming of13mtr Long ST Poles in mix 1:2:4 ( as per REC construction standard) using 20mm crush stone aggregate including shuttering ,form work etc. |
| 22 | Providingand laying of Cement bottoming of11mtr Long ST Poles in mix 1:2:4 ( as per REC construction standard) using 20mm crush stone aggregate including shuttering ,form work etc. |
| 23 | Providingand laying of Cement bottoming of9mtr Long ST Poles in mix 1:2:4 ( as per REC construction standard) using 20mm crush stone aggregate including shuttering ,form work etc. |
| 24 | Providing and fixing of Galvanisedspiral Earthing (in a separate pit) of8 SWG, G.I wire of 115 turns confirming to REC-J1 construction standard |
| 25 | Fixing of Galvanisedspiral Earthing (in a separate pit) of8 SWG, G.I wire of 115 turns confirming to REC-J1 construction standard |
| 26 | Providing and Fixing of Earthing complete with by GI Pipe 40mm or GI rod 20mm 2.5m long through GI strip |
| 27 | Fixing of Earthing complete with by GI Pipe 40mm or GI rod 20mm 2.5m long through GI strip |
| 28 | Providing and fixing of 33KV Galvanised Guy Set(Guy wire,Guy Rods,Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof (complete) |
| 29 | Fixing of 33KV Galvanised Guy Set(Guy wire,Guy Rods,Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof (complete) |
| 30 | Dismanteling of 33KV Galvanised Guy Set(Guy wire,Guy Rods,Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof (complete) |
| 31 | Providing and fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.1 ACSR |
| 32 | Providing and fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.15ACSR |
| 33 | Providing and fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.2 ACSR |
| 34 | Fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to (Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.1 ACSR |
| 35 | Fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to (Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.15 ACSR |
| 36 | Fixing of P.G Clamps /Pad Clamps/ T-Clamps heavy duty conforming to (Aluminium to Aluminium as 2848,Part 1 Standard, 4-bolt type suitable for 0.2ACSR |
| 37 | Laying,stringing ,tensioning and binding of 0.2 ACSR Conductor as per REC Construction standard (material to be provided by the department) |
| 38 | Laying,stringing ,tensioning and binding of 0.15 ACSR Conductor as per REC Construction standard (material to be provided by the department) |
| 39 | Laying,stringing ,tensioning and binding of 0.1 ACSR Conductor as per REC Construction standard (material to be provided by the department) |
| 40 | Laying,stringing ,tensioning and binding of 0.05ACSR Conductor as per REC Construction standard (material to be provided by the department) |
| 41 | Supply,Laying,stringing ,tensioning and binding of 0.2 ACSR Conductor as per REC Construction standard |
| 42 | Supply,Laying,stringing ,tensioning and binding of 0.15 ACSR Conductor as per REC Construction standard |
| 43 | Supply,Laying,stringing ,tensioning and binding of 0.1 ACSR Conductor as per REC Construction standard |
| 44 | Supply,Laying,stringing ,tensioning and binding of 0.05 ACSR Conductor as per REC Construction standard |
| 45 | Re-stringing of 0.2 ACSR Conductorincluding tensioning, binding etc |
| 46 | Re-stringing of 0.15 ACSR Conductorincluding tensioning, binding etc |
| 47 | Re-stringing of 0.1ACSR Conductorincluding tensioning, binding etc |
| 48 | Loading of 13 mtr Long ST Pole (ST-410SP-69)including manual carriage from stacking site upto loading site upto a lead of 25mtr |
| 49 | Loading of 11 mtr Long ST Pole (ST-410SP-56)including manual carriage from stacking site upto loading site upto a lead of 25mtr |
| 50 | Loading of 9 mtr Long ST Pole (ST-410SP-33)including manual carriage from stacking site upto loading site upto a lead of 25mtr |
| 51 | Unloading of 13 mtr Long ST Pole (ST-410SP-69)including manual carriage (manual) upto dumping site and then proper stacking upto a lead of 25mtr |
| 52 | Unloading of 11 mtr Long ST Pole (ST-410SP-56) including manual carriage (manual) upto dumping site and then proper stacking upto a lead of 25mtr |
| 53 | Unloading of 9mtr Long ST Pole (ST-410SP-33) including manual carriage (manual) upto dumping site and then proper stacking upto a lead of 25mtr |
| 54 | Manual Carriage of ST Poles Upto first 100mtr lead |
| 55 | Manual Carriage of ST Poles for every additional 50mtr or part there off |
| 56 | Loading of Steeland sundry items likeCGI sheet, nuts and bolts, Angle Iron, hardware fittings , cross arms etcincluding manual carriage,proper stacking and sorting etcupto loading siteupto 50mtr |
| 57 | Unloading of Steeland sundry items likeCGI sheet, nuts and bolts, Angle Iron, hardware fittings , cross arms etc including manual carriage,proper stacking and sorting etcupto loading site upto 50mtr |
| 58 | Manual Carriage of Sundry Items Upto first 100mtr lead |
| 59 | Manual Carriage of Sundry Items for every additional 50mtr or part there off |
| 60 | Loading of Conductor Reels ( 0.1ACSR/ 0.2 ACSR/ 0.15 ACSR) including manual carriage from dumping site and then proper stacking |
| 61 | Unloading of of Conductor Reels ( 0.1ACSR/ 0.2 ACSR/ 0.15 ACSR ) including manual carriagestacking site upto loading |
| 62 | Supply, installation,testing and commissioning of 33kV Polymeric composite Disc Insulator (36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm) suitable for0.1ACSR |
| 63 | Supply, installation,testing and commissioning of 33kV Polymeric composite Disc Insulator (36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm) suitable for 0.15ACSR |
| 64 | Supply, installation,testing and commissioning of 33kV Polymeric composite Disc Insulator (36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm) suitable for0.2ACSR |
| 65 | Installation,testing and commissioning of of 33kV Polymeric composite Disc Insulator (36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm) suitable for0.1ACSR |
| 66 | Installation,testing and commissioning of of 33kV Polymeric composite Disc Insulator (36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm) suitable for0.15ACSR |
| 67 | Installation,testing and commissioning of of 33kV Polymeric composite Disc Insulator (36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm) suitable for0.2ACSR |
| 68 | Supply,installation,Testing and commissioning of 33kV Polymeric composite Pin Insulator (36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm) suitablefor0.1ACSR |
| 69 | Supply,installation,Testing and commissioning of 33kV Polymeric composite Pin Insulator (36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm) suitable for0.15ACSR |
| 70 | Supply,installation,Testing and commissioning of 33kV Polymeric composite Pin Insulator (36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm) suitable for0.2ACSR |
| 71 | Installation,Testing and commissioning of 33kV Polymeric composite Pin Insulator (36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm) suitable for0.1ACSR |
| 72 | Installation,Testing and commissioning of 33kV Polymeric composite Pin Insulator (36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm) suitable for0.15ACSR |
| 73 | Installation,Testing and commissioning of 33kV Polymeric composite Pin Insulator (36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm) suitable for0.2ACSR |
| 74 | Supply,installation,Testing and commissioning of 11kV Polymeric composite Pin Insulator (12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm) suitable for0.1ACSR |
| 75 | Supply,installation,Testing and commissioning of 11kV Polymeric composite Pin Insulator (12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm) suitable for0.05ACSR |
| 76 | Installation,Testing and commissioning of of 11kV Polymeric composite Pin Insulator (12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm) suitable for0.1ACSR |
| 77 | Installation,Testing and commissioning of of 11kV Polymeric composite Pin Insulator (12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm) suitable for0.05ACSR |
| 78 | Providing and fixing of 11kV Polymeric composite Disc Insulator(12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm) suitable for0.1ACSR |
| 79 | Providing and fixing of 11kV Polymeric composite Disc Insulator(12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm) suitable for0.05ACSR |
| 80 | Fixing of 11kV Polymeric composite Disc Insulator (12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm) suitable for0.1ACSR |
| 81 | Fixing of 11kV Polymeric composite Disc Insulator (12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm) suitable for0.05 ACSR |
| 82 | Providing and fixing of 33kV tension fitting heavy duty type suitable for 0.1ACSR |
| 83 | Providing and fixing of 33kV tension fitting heavy duty type suitable for 0.15ACSR |
| 84 | Providing and fixing of 33kV tension fitting heavy duty type suitable for 0.2ACSR |
| 85 | Fixing of33kV tension fitting heavy duty type suitable for 0.1ACSR |
| 86 | Fixing of33kV tension fitting heavy duty type suitable for 0.15ACSR |
| 87 | Fixing of33kV tension fitting heavy duty type suitable for 0.2ACSR |
| 88 | Providing and fixing of 11kV tension fitting heavy duty type suitable for 0.1ACSR |
| 89 | Fixing of 11kV tension fitting heavy duty type suitable for 0.1ACSR |
| 90 | Providing and fixing of 11kV tension fitting heavy duty type suitable for 0.05ACSR |
| 91 | Fixing of 11kV tension fitting heavy duty type suitable for 0.05ACSR |
| 92 | Providing and fixing of danger plates (6\"X8\"X4mm thick) with clamps |
| 93 | Fixing of danger plates (6\"X8\"X4mm thick) with clamps |
| 94 | Providing and fixing of anti climbing devices with clamps |
| 95 | Fixing of anti climbing devices with clamps |
| 96 | Providing and fixing of fabricated GI Channel / Angle Iron of sorts as per site requirement |
| 97 | Fixing of fabricated GI Channel / Angle Iron of sorts as per site requirement |
| 98 | Providing and Fixing of jumper sets (3 pieces) for 33KV line |
| 99 | Fixing of jumper sets (3 pieces) for 33KV line |
| 100 | Supply,erection,testing and commissioning of 33KV, 185sqmm Single coreAluminium, round wire Armoured XLPE Cable , FRLS |
| 101 | Supply,erection,testing and commissioning of 33KV, 240sqmm Single coreAluminium, round wire Armoured XLPE Cable , FRLS |
| 102 | Supply,erection,testing and commissioning of 33KV, 300sqmm Single coreAluminium, round wire Armoured XLPE Cable , FRLS |
| 103 | Supply,erection,testing and commissioning of 33KV,400sqmm Single coreAluminium, round wire Armoured XLPE Cable , FRLS |
| 104 | Supply,erection,testing and commissioning of 33KV,630sqmm Single coreAluminium, round wire Armoured XLPE Cable , FRLS |
| 105 | Erection,testing and commissioningof 33KV, 185sqmm Single coreAluminium, round wire armoured XLPE Cable |
| 106 | Erection,testing and commissioningof 33KV, 240sqmm Single coreAluminium, round wire armoured XLPE Cable |
| 107 | Erection,testing and commissioningof 33KV, 300sqmm Single coreAluminium, round wire armoured XLPE Cable |
| 108 | Erection,testing and commissioningof 33KV, 400sqmm Single coreAluminium, round wire armoured XLPE Cable , |
| 109 | Erection,testing and commissioningof 33KV, 630sqmm Single coreAluminium, round wire armoured XLPE Cable , |
| 110 | Providing and Fixing of Cable Termination Kits (indoor/outdoor) for33KV, 185sqmm Single coreAluminium, round wire armoured XLPE Cable |
| 111 | Providing and Fixing of Cable Termination Kits (indoor/outdoor) for33KV, 240sqmm Single coreAluminium, round wire armoured XLPE Cable |
| 112 | Providing and Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 300sqmm Single coreAluminium, round wire armoured XLPE Cable |
| 113 | Providing and Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 400sqmm Single coreAluminium, round wire armoured XLPE Cable |
| 114 | Providing and Fixing of Cable Termination Kits (indoor/outdoor) for33KV, 630sqmm Single coreAluminium, round wire armoured XLPE Cable |
| 115 | Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 185sqmm Single coreAluminium, round wire armoured XLPE Cable |
| 116 | Fixing of Cable Termination Kits (indoor/outdoor) for33KV, 240sqmm Single coreAluminium, round wire armoured XLPE Cable |
| 117 | Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 300sqmm Single coreAluminium, round wire armoured XLPE Cable |
| 118 | Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 400sqmm Single coreAluminium, round wire armoured XLPE Cable |
| 119 | Fixing of Cable Termination Kits (indoor/outdoor) for 33KV, 630sqmm Single coreAluminium, round wire armoured XLPE Cable |
| 120 | Providng and fixing of guard netting of existing 33KV lineusing 8 SWG GI wire comprising of minimum of 10 No. crossing per span complete with eye bolts |
| 121 | Fixing of guard netting of existing 33KV lineusing 8 SWG GI wire comprising of minimum of 10 No. crossing per span complete with eye bolts |
| 122 | Providing and fixing of extension / risers of Angle Iron /Channel Iron |
| 123 | Fixing of extension / risers of Angle Iron /Channel Iron |
| 124 | Providing and fixing Aluminium Jointing Sleeves |
| 125 | Fixing Aluminium Jointing Sleeves |
| 126 | Supply, installation,testing and commissioning of 33 kV Isolator with Earthing Blade (36kV,800A, Outdoor,3 poles, 25 kA) |
| 127 | Supply, installation,testing and commissioning of 33 kV Isolator without Earthing Blade (36kV,800A, Outdoor,3 poles, 25 kA) |
| 128 | Installation,testing and commissioning of 33 kV Isolator with Earthing Blade (36kV,800A, Outdoor,3 poles, 25 kA) |
| 129 | Installation,testing and commissioning of 33 kV Isolator without Earthing Blade (36kV,800A, Outdoor,3 poles, 25 kA) |
| 130 | Extensive Branch cutting of trees coming in the coridor 33KV line including cutting of trees beneath the 33KV lineand stacking of serviceable material and disposal of unservicable material.(complete job) |
| 131 | Felling trees of the grith (measured at height of 1mtr above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unservicable material. |
| 132 | Beyond 30cm girth upto and including 60cm girth |
| 133 | Beyond 60cm girth upto and including 120cm girth |
| 134 | Beyond 120cm girth upto and including 240cm girth |
| 135 | Above 240cm grith |
| 136 | Note: The material utilized/works executed shall be stritctly as per REC Standards with Latest amendments there off. |