Ioaod Engg Rate Contract For Site Survey, Soil Investigation, Structural Designing, Quantity Surveying For Development, Modernization, Upgradation Of New Existing Retail Outlets, Consumer Pump, Afss Under Ioaodso Ioaod Engg Rate Contract For Site S
Tender Overview
Project Description
Ioaod Engg Rate Contract For Site Survey, Soil Investigation, Structural Designing, Quantity Surveying For Development, Modernization, Upgradation Of New Existing Retail Outlets, Consumer Pump, Afss Under Ioaodso Ioaod Engg Rate Contract For Site Survey, Soil Investigation, Structural Designing, Quantity Surveying For Development, Modernization, Upgradation Of New Existing Retail Outlets, Consumer Pump, Afss Under Ioaodso
BOQ
| Sl. No. | Item Description |
| 1 | 1.0: Preliminary Works comprising of following activities with 3 Copies/Prints of all documents. |
| 2 | 1.1: Site visit by qualified engineers/main consultant upon finalization of land. Ascertaining jurisdiction of area and doing General Survey of land as per standard practice and verification of boundaries as per the key plan submitted by the IOC. |
| 3 | 1.2:Carrying out Total Station Survey of finalized piece of land & based on revenue documents provided by IOCL by qualified Engineer and with the help of instruments such as TS, GPS, etc. complete.Item includes, providing detailed layout drawings of Existing Levels, proposed Finished Driveway Levels (FDL) in discussion with IOCL officers, Perma nent Bench Mark (PBM) or Temporary Bench Mark (TBM), Boundaries of the plot, Contours, Major References (Govt. building / Public building / Culvert / HT lines / Chimneys) within 300 m, nearest road intersection, front road, etc. complete. Item also includes providing quantities for cutting & filling based on FDL suggested by IOCL.The grid for levels should be spaced at 3 M on both the directions and area covered is up to 5000 Sqm including minimum 10 M wide strip beyond plot boundaries & up to front road. Rate is inclusive of submission of complete report in three sets along with soft copy in CD.Payment will be made for each site. |
| 4 | For additional area of 1000 sqm or part thereof |
| 5 | Soil investigation by approved agency (ISO certified / Govt. approved / any other approved by IOCL) including all applicable field investigations such as boring two holes 150 NB up to 6 M depth / refusal strata (N value greater than 50) whichever earlier,Standard Penetration Test at every 1.5 M or as per site conditions, collecting disturbed & undisturbed soil samples at every 1.5 M depth or as per site conditions, determination depth of water table, etc. and laboratory investigations such as testing of samples collected from field (disturbed / undisturbed soil samples), Sieve Analysis, Atterberg\"s Limit, Particle Size Analysis, Natural Moisture Content, Wet & dry density, Specific Gravity, Tri-axial Compression, Consolidation, Testing of water sample for construction purpose including for harmful salts, CBR value, etc. or any other required tests but not mentioned here for deriving Soil Bearing Capacity (SBC), Allowable Bearing Capacity (ABC) for designing Sales Building, Boundary Wall / Retaining Wall, Culverts, Trenches, Canopy Foundation, Driveway, etc. complete.All tests will be carried as per latest & relevant IS codes of practice as applicable.Item also includes comments / Recommendations of Expert on type of foundation based on soil investigations.Rate is inclusive of submission of complete report in three sets along with soft copy in CD. |
| 6 | For each additional bore hole up to 6 m depth or refusal strata (N value greater than 50) whichever earlier |
| 7 | Core cutter test of the existing driveway & recommending modifications. Item includes cost of three samples of core cutter, testing & submission of test report.Test will be carried as per latest & relevant IS codes of practice as applicable.Rate is inclusive of sample collection , submission of complete report in three sets along with soft copy in CD.Payment will be made for each site. |
| 8 | Designing |
| 9 | :Sales Building having RCC framed structure (considering two storey) including Schedule of Doors, Windows, Ventilators, Layout Plan, Foundation details, RCC details, Reinforcements details, various Sections, Joinery details, Sanitary details & line sketch, Electrical details & line sketch, Drainage details & line sketch, Flooring schedule, etc. complete. Item incudes designing of buiding upto 80 Sqm for all type of bearing capacity including estimation |
| 10 | Sales Building having RCC framed structure (considering two storey) including Schedule of Doors, Windows, Ventilators, Layout Plan, Foundation details, RCC details, Reinforcements details, various Sections, Joinery details, Sanitary details & line sketch, Electrical details & line sketch, Drainage details & line sketch, Flooring schedule, etc. complete. Item incudes designing of buiding frabove 80 to 250 Sqm for all type of bearing capacityas per requirement including necessary two storey foundation |
| 11 | Boundary wall / retaining wall, sloping shoulders, main drain/Culvert , pipe line trench, kerb walls, toe walls, electric panel room, etc. All requisite detailed drawings including foundation, RCC, reinforcement, etc. complete for tendering & execution of the work in all respect including submission of design calculation and structural stability certificate . Area up to 3000 Sqm is incuded in the Item. Maximum 5 sections of boundary wall. |
| 12 | Design for each additional section of boundary wall |
| 13 | 3.0 : Preperation of File/Drawingfor new RO or existing RO including Soft copy (Pdf and AutoCAD file) of all documents mentioned herewith (one complete set), with all required Affidavits/ Undertakings/ Bonds/ Declarations/ Documents/ Drawings for submission to various Statutory Authorities with necessary color coding for submission to: |
| 14 | District Authority for NOC |
| 15 | Highway Authority for Approval, 3 original sets & 6 xerox sets . Item includes visit to the site and survey of 1.5 km on each side of site as per NHAI requirement. |
| 16 | PESO for Construction Approval |
| 17 | Local Authority for Building Plan Approval |
| 18 | PESO for Licence |
| 19 | CCOE for Amendments |
| 20 | Digitization of layout from hard copy |
| 21 | Ammonia prints |
| 22 | Size A0 |
| 23 | Size A1 |
| 24 | Size A2 |
| 25 | Size A3 |
| 26 | Black & white prints (Lessor printer) |
| 27 | Size A0 |
| 28 | Size A1 |
| 29 | Size A2 |
| 30 | Size A3 |
| 31 | Colured prints (thick glossy paper) |
| 32 | Size A0 |
| 33 | Size A1 |
| 34 | Size A2 |
| 35 | Size A3 |
| 36 | Size A4 |
| 37 | Liasinoing and Follow UP with PESO |
| 38 | Arranging Tank TestingCertificate through competent person recognised from CCOE Nagpur. |
| 39 | Arranging Safety Certificate through competent person recognised from CCOE Nagpur ). |
| 40 | Structural design of canopy, Tank Lorry Filling Bay or any other structures including all required details of joints & bill of materials for structural steel, layout plan, foundation details, RCC details, reinforcement details, various sections, joinery details, eletrical cables & line sketch, drainage details & line sketch etc complete in all respect including submission of design calculation and structural stability certificate.Item rate is inclusive of submission of design calculations, structural stability certificate, soft copy of drawings (both auto CAD & pdf) & 3 set of greyscale printout of drawings in ISO A3 size |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender