Repair And Maint Of Summer Appliances Including Desert Cooler And Water Cooler At Dipac Area Of Delhi Cantt And Repair And Maint To Servo Voltage Stabilizer, Voltage Stabilizer Of Window / Split Acs And Other Misc Works Under Ge Utility P And M Delhi, delhi-Delhi

Military Engineer Services-MES has published Repair And Maint Of Summer Appliances Including Desert Cooler And Water Cooler At Dipac Area Of Delhi Cantt And Repair And Maint To Servo Voltage Stabilizer, Voltage Stabilizer Of Window / Split Acs And Other Misc Works Under Ge Utility P And M Delhi. Submission Date for this Tender is 07-06-2022. Voltage Stabiliser Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

32140973
Corrigendum : Repair And Maint Of Summer Appliances Including Desert Cooler And Water Cooler At Dipac Area Of Delhi Cantt And Repair And Maint To Servo Voltage Stabilizer, Voltage Stabilizer Of Window / Split Acs And Other Misc Works Under Ge Utility P And M Delhi
Open Tender
Indian
Delhi
delhi
07-06-2022

Tender Details

Repair And Maint Of Summer Appliances Including Desert Cooler And Water Cooler At Dipac Area Of Delhi Cantt And Repair And Maint To Servo Voltage Stabilizer, Voltage Stabilizer Of Window / Split Acs And Other Misc Works Under Ge Utility P And M Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-May-2022 Corrigendum No 1 BOQ 31-05-2022
2 18-May-2022 Corrigendum No 1 Date 31-05-2022
3 31-May-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-06-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 81060.0 /-
Tender Value
INR 40.53 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINTENANCE OF SUMMER APPLIANCES INCLUDING DESERT COOLER AND WATER COOLER AT DIPAC AREA OF DELHI CANTT AND REPAIR AND MAINTENANCE TO SERVO VOLTAGE STABILIZER, VOLTAGE STABILIZER OF WINDOW / SPLIT ACS AND OTHER MISC WORKS UNDER GE(U) P&M DELHI CANTT-10.
Sl. No. Item Description
1Taking downfor servicingof split type AC 1.5/2 TR Capacityincluding cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing connections from heating mode to cooling mode or vice-versa and keepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed.
2Taking downfor servicingofWindow type AC 1.5/2 TR Capacityincluding cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa andkeepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing positioncomplete all specified and as directed. Notes for Ser Item No 1 & 2 :- (i) Replacement of defectivespares for making the AC units in satisfactory working conditionwill be measured & paidseparately under relevant items and Labour charges for taking out old spares & refixing of new sparesshall deemed to be included in unit quoted rate. (ii) Penaltywill be charged for not attending complaint from 12 Hoursto 24 hours Rs. 500/- each complaint. Furtherif complaint not attended and rectifiedwithin 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioningtime of complaint,for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues.
3Supply onlyPVC pipemedium grade 15mm bore including fittings.
4Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for window AC of capacity 1.5/2/4 TR.
5Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for indoor of inverter type split AC of capacity 1.5/2 TR .
6Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for outdoor of inverter type split AC of capacity 1.5/2 TR.
7Supply only Starting capacitor 80-100 MFD .
8Supply only Starting capacitor 100-120 MFD.
9Supply only Running capacitor 50+6 MFD.
10Supply only Running capacitor 45+5 MFD.
11Supply only condenser motor 1/3 HP suitable for window type AC double shaft.
12Supply only Starting Relay 1622.
13Supply only Running capacitor 36 MFD.
14Supply only Thermostat switch 2059/2064/2054 .
15Supply only copper filter double capilary pencil type.
16Supply only regulator knob suitable for 1.5TR/2.0TR capacity AC.
17Supply only flexible copper conductor cable, 3 corePVC insulated & PVC sheathed of size 1.5sqmm. Note for item No 3 to 17:- Labours of item Nos 3 to 17 to be incorporated in item Nos 1 & 2 here-in-before.
18Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the window type Air Conditioner of Cap2 Ton,of any make any type from any locationandSupply , Installingand testing of new sealed unit compressoralongwith test certificate from manufacturer includingcleaning and removing dust/dirt from the cooling coil condenser coilwith necessary modification capillary tube etc&Charging of Gas R-22/R-134A/R-32 and commissioning complete all as specified & as directed. Note :- Transportation Charges from siteto trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted.
19-ditto- all as per item No. 18 abovebut window type Air Conditioner ofCapacity 1.5 TR complete all as specified & as directed.
20-ditto- all as per item No. 18 abovebut spilt type Air Conditioner ofCapacity 2 TR complete all as specified & as directed.
21-ditto- all as per item No. 18 abovebut spilt type Air Conditioner ofCapacity 1.5 TR complete all as specified & as directed.
22Supply and fixing in repairs of 1.5 TR capacity window type AC kit including condenser coil, cooling coil, front grill blower motor, chasis, base plate complete set except compressor complete all as specified & as directed.
23-ditto- all as per item No. 22 above but spilt/window type Air Conditioner of capacity2 TR complete all as specified & as directed.
24Taking down unserviceable indoor unitof split type AC of any make andsupply & fixing new indoor unit complete set suitable for 1.5 TRcapacity complete all as specified & as directed.
25-ditto- all as per item No. 24 above but spilt type Air Conditioner of capacity2 TR complete all as specified & as directed.
26Supply and fixing in repairs of1.5TR capacity split type Air Conditioner outdoor kit including condenser coil, blower motor, chasis, base plate complete set except compressor complete all as specified & as directed.
27-ditto- all as per item No. 26 above but spilt type Air Conditioner of capacity2 TR complete all as specified & as directed.
28Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded,unsheathed1100 volts grade in PVC casing caping(heavy grade) of adequate size with all fittings and casing capingaccessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694)as earth wire including taking down old unserviceable sub main wiring complete all as specified and as directed. {Notes :-(i) Two runs of cable with one run earth wire and PVC casing capping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing capping. (iv) Suitable color code of wire must be ensured for phase/ neutral/ earth.}
29Supply & fixing in repairs metal clad plug with two pin of capacity 20 Ampscomplete all as specified & as directed.
30Supply and fixing in repairs of metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps including taking down old unserviceable metal clad socket complete all as specified & as directed.
31Supply and fixing in repairs of MCB SP 240 volts 6 to 32 Amps, 10 kA, "C" curve complete all as specified and as directed.
32Material and labour for detecting leakages of gases in window type/ split type AC unit of capacity 1.5/ 2TR at any location, checking the leakages of gas and rectify the leakages by brazing of copper tubes testing and commissioning complete all as specified & as directed.
33Supply and fillingrefrigerant gas R-22/R-410A/R-32/ R-134A in window type /Split Type AC unit of capacity 1.5/2TR,Deep Freezer, Refrigerator, Water Cooler of any capacitycomplete in satisfactory working condition complete all as specified & as directed.
34Supply and fixing in repairs of front grill of 1.5 TR capacity window type AC approved make complete all as specified & as directed.
35Supply and fixing in repairs of front grill of 2 TR capacity window type AC approved make complete all as specified & as directed.
36Taking down unserviceable reversible valve for split/ window type AC of capacity 1.5TR and supply & fixing new reversible valve with solenoid coil including required copper pipe complete all as specified and as directed. (Make:- As per sample) (Note:- Supply & filling of refrigerant gasshall be measured and paid under relevent item.)
37-ditto- all as per item No. 37 abovebut split/ window type Air Conditioner ofCapacity 2 TR complete all as specified & as directed.
38Supply & fixing in repairs heavy duty copper pipe of size 6mm (1/4") dia/ bore complete including insulation brazing, welding, nuts,bolts and screws of required size complete all as specified and as directed.
39-ditto- all as per item No. 39 above but copper pipe of size 12mm (1/2") dia/ bore complete all as specified and as directed.
40-ditto- all as per item No. 39 above but copper pipe of size 15mm (5/8") dia/ bore complete all as specified and as directed.
41Supply and fixing of out door stand for split type AC/ desert cooler of any capacity made up of angle iron frame of any size grouting on wall or floor as directed and applying of two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer including taking down old unserviceable one complete all as specified and as directed.
42Supply & fixing in repair Indoor Air blower motor for Split type AC 1.5 TR & 2 TR capacity complete all as specified & as directed.
43Supply & fixing in repair Window AC air blower motor for 1.5 TR & 2 TR capacity AC complete all as specified & as directed.
44Supply & fixing in repairs Window AC condenser fan blade plastic body for 1.5 TR & 2 TR capacity AC complete all as specified & as directed.
45Supply & fixing in repairsSplit AC Condenser fanblade plastic body for 1.5 TR & 2 TR capacity AC complete all as specified & as directed.
46Supply & fixing in repairs running capacitor of 2.5 MFD capacitycomplete all as specified & as directed.
47Supply & fixing in repairs running capacitor of 4 MFD capacitycomplete all as specified & as directed.
48Supply & fixing in repairsrunning capacitor of 6 MFDcapacitycomplete all as specified & as directed.
49Supply only remote control including battery for split AC Cap 1.5/2 TR of make as per site requirement and replacement of old one.
50Supply & fixing in repairs plastic louvers (Front panel)for Window type AC of capacity 1.5/2 TR complete all as specified & as directed.
51Supply & fixing in repairs of selector switch for fan/cooling of Window AC 1.5/2 Ton complete all as specified & as directed.
52Supply & fixing in repairs of suctionand discharge valve set of size 15mm (5/8""), 6mm (1/4"") and 12mm (1/2"")for Split AC 1.5/2 TR capacity complete all as specified & as directed. {Note:-(i) 15mm (5/8"") or 6mm (1/4"") and 12mm (1/2"") make one set (ii) Supply & filling of refrigerant gasshall be measured and paid under relevent item.}
53M&L for 4 mm thick plywood of grade BWR, type BB including necessary fixing accessories and taking down old one and applying two coat of synthetic enamel paint(1st grade quality) over a coat of pink primer complete all as specified & as directed.
54Disconnecting the mains and taking out the unserviceable condenser coilof window type AC of capacity 1.5/ 2TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns complete all as specified & as directed.
55-ditto- all as per item No. 54 above but spilt type Air Conditioner Capacity 1.5/ 2 TR.
56Dismantling the evaporator/cooling coil of window type Air Conditioner of capacity 1.5/ 2TR, checking the leakages of gas and rectify the leakages by brazing or as other manner and refixing the same complete all as specified & as directed.
57-ditto- all as per item No. 57 above but spilt type Air Conditioner Capacity 1.5/ 2 TR complete all as specified & as directed.
58Taking down unserviceable insulation for copper pipe of any dia, supply and fixing new insulation for copper pipes suitable for Split AC of capacity from 1.5 to 2.0 TR complete all as specified and as directed.
59Taking down unserviceable contactor for split type AC of capacity 1.5 TR/ 2.0TR, supply and fixing new contactor single phase suitable for split type ACcomplete allas specified and as directed.
60Disconnecting and removing of serviceable window type AC of capacity 1.5 TR/ 2.0TR of any make and model along with stabilizer from its position and fixing the same in other location including all other fixing accessories and testing complete allas specified and as directed.
61Disconnecting and removing of serviceable split type AC of capacity 1.5 TR/ 2.0TR of any make and model along with stabilizer (Indoor & Outdoor Unit) from its position and fixing the same in other location including all other fixing accessories and testing complete allas specified and as directed.
62Disconnecting the unserviceable PCB compatible from existing Window/ Split type AC of capacity 1.5/ 2TR and refixing after necessary repair for satisfactory functioning of the AC unit complete allas specified and as directed.
63Dismantling and removing defective burnt blower unit motor ofcapacity 1.5/ 2.0 TR of any make ofwindow type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete allas specified and as directed.
64Dismantling and removing defective burnt blower unit motor ofcapacity 1.5/ 2.0 TR of any make of indoor units of split type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete allas specified and as directed.
65Dismantling and removing defective burnt blower unit motor ofcapacity 1.5/ 2.0 TR of any make of outdoor units of split type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete allas specified and as directed.
66Supply & fixing in repairs of blower fan blade of indoor unit for Split 1.5 TR & 2 TR capacity complete all as specified & as directed.
67Supply & fixing in repairs of metal clad socket of 20 Amps complete all as specified & as directed.
68Disconnecting from mains and taking downfor servicingofWater Cooler ofCapacity 40/80, 60/120,Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs,fan andblower, etc., andkeepingthe Water coolerunit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed. Note :- 1. Replacement of defectivespares for making the water cooler units in satisfactory working condition will be measured & paidseparately under relevant items as "Supply only" and Transportation & labour charges for taking down old spares and fixing of new sparesshall deemed to be included in unit rate quoted above.
69Supply onlyfollowing new spare parts of Water cooler unit ofcapacity 40/80 to 60/120 Ltrs:-
70Starting relay suitable for 40/80 , 60/120 Ltr.
71Starting Capacitor 25 MFD.
72Running Capacitor 10 MFD .
73PVC flexible drain Hose pipe 40 mm.
74Condenser fan blade aluminium body for Motor 1/32HP, 1/35HP.
75Over load protector device for 60/120 ltrs capacity water cooler.
76Over load protector device for 40/80 ltrs capacity water cooler.
77Thermostatswitch.
78Self closing chromium plated push taps for water cooler Capacity 40/80,60/120 Ltr . Note for item No 69.01 to 69.09 :- Labour of item No 69.01 to 69.09 to be incorporated in item No 68 here-in-before
79Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity60/120 Ltrs from any location andsupply installation & testing of new sealed unit compressorof similar capacity in same locationalongwith test Certificate from manufacturer and cleaning of condenser by machine doing vaccum on the fully system and supply and charging of oil gas and other necessary lubricants including reconnecting the electric and water connections, transportaion& testing complete all as specified and as directed.
80-ditto- all as per item No. 76 above butWater coolerofcapacity 40/80 Ltrs.
81Disconnecting the electric mains and taking out unserviceable condenser fan motor1/16 HP from water cooler cap.60/120 Ltr and supply and fixing of new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as specified and as directed.
82All as per item No. 78 above but 1/32 HP Water coolerofCapacity 40/80 Ltrs.
83Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water/Coolers of capacity 60/120 Ltrs complete all as specified & as directed.
84-ditto- all as per item No. 80 aboveWater/Coolers of capacity 40/80Ltrs.
85Dismantling the evaporator/cooling coil of water cooler capacity 60/120 & 40/80 Ltrs, checking the leakages of gas and rectify the leakages by brazing or as other manner and refixing in same position complete all as specified & as directed.
86Cleaning & removing the existing paint ofWater Coolers capacity60/120 & 40/80 Ltrs by rubbing & preparing the surface smooth & applying one coat of zinc chrome primer and two coats of synthetic enamel paint (1st grade quality) by spray gun machine of colour as complete all as specified & as directed.
87Taking up or down GI steel tubing and connections and removing off site15mm bore of pipecomplete all as specified and as directed.
88Supply and fixinggalvanised steel tubing 15 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.)fixed on wall or floor complete all as specified and as directed.
89Supplying and fixing in repairs stop valve 15mm bore dia, fancy type chromium plated with long shank and cup (concealed type), screwed both ends for iron pipe or for unionscomplete all as specified and as directed.
90Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections pipe of 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed.
91Material and labour for detecting of leakages of gases in Water cooler, Refrigerator, deep freezer of any capacity at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition complete all as specified & as directed.
92Disconnecting from mains and taking downfor servicingof Refrigerator/Deep freezerofCapacity 165/180/195/310/330/450 and 500 Ltrsincluding detecting the leakage of gas and refilling of refrigerant,cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., andkeepingthe Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed. Note :- 1. Replacement of defectivespares for making the Refrigerator/ Deep Freezer units in satisfactory working condition will be measured & paidseparately under relevant items as "Supply only" and Labour charges for taking out old spares and fixingof new sparesshall deemed to be included in unit rate quoted.
93Supply onlyfollowing new spare parts of Refrigerator/Deep freezer 165/180/195/310/330/450 and 500 Ltrs capacity:-
94Thermostat switchwith Knob.
95Starting relay 1/6 H.P.Open type with O.L.P.
96Starting relay 1/8 H.P. open type with O.L.P.
97Copper filter single capilary pencil type.
98Vegetable tray PVC for 165 to 330 Ltr capacity.
99Defrost tray for refrigerator capacity 165 to 330 Ltr.
100PVC ice tray flexible.
101Refrigerator bottle shelf for 165 to 330 ltr capacity .
102Waste water tray suitable for different type of Refrigerator.
103Freezer door for 165/180/195 Ltr capacity .
104Freezer door for 280/300/330 Ltr capacity .
105Door Lock for refrigerator 165 to 330 ltrs.
106Door switch for refrigerator 165 to 330 ltrs.
107Interior light fittings with bulb.
108Door handle suitable for 165 to 330 Ltrs.
109Refrigerator Glass shelves of capacity 165/180/195 Ltrs.
110Refrigerator Glass shelves of capacity 280/300/310/330 Ltrs. Note for item No 84.01 to 84.17 :- Labour of item No 84.01 to 84.17 to be incorporated in item No 83. here-in-before
111Disconnecting from mains and taking down the unserviceable compressorunit of Refrigerator of any make and type and providing New Compressor suitable for 165 to 195 ltr capacityalongwith test certificate from manufacturer including supply of therefrigerant gas R-134A and filling and replacement of filter and put in working condition complete all as specified & as directed. Note :-The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor"s repair workshop and back.
112All as per item No. 85above but for following capacity of Refrigerator:-
113Refrigerator 280/300/310/330 Ltrs capacity.
114Deep Freezer 400 Ltrs capacity.
115Deep Freezer 500 Ltrs capacity.
116Taking out unserviceable evaporator /freezer from the refrigerator & supply & fixing evaporator/freezer made out of aluminium press type of capacity 280/300/310/330/400 and 500 ltrwith freezer frame and door including connection, complete all as specified & as directed.
117-ditto- all as per item No. 87 but capacity of the refrigerator 165 to 195Ltrs capacity complete all as specified & as directed.
118Taking down desert cooler of any type (Steel body/Plastic body) and any capacity from any height / floor andrefixing the same in same location after repair work/ overhauling all as required at site. Note:- Repair work not included in the quoted rate.
119Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface.Repainting the complete desert coolers ie side panel, bracket, body & desert cooler stand with two coats of synthetic enameled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “ GE(U) P&M (MES)” letter size of 50mm height in stencil in black/white including servicingandgreasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as per site requirement.
120Supply and fixing in repairs wood wool padapproximate weight 800 - 900gms of size 24” sweep desert cooler as per existingcomplete all as specified and directed.
121-ditto- all as per item No 96 above but approximate weight 700 - 800gms and20” sweep.
122Supply and fixing in repairs submersible pump motor 230 Volts , single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified & as directed.
123Supply and fixing in repairs of exhaust fan motor copper woundedhaving 1400 RPM, 150 watts with 500mm sweep suitable for operation on 230 volts, 50Hz, AC supply including fan brackets/ clamps of suitable size and all fixing accessories complete all as specified & as directed.
124Supply and fixing in repairs of desert cooler copper wounded kitfan motor of capacity 90 Watt complete all as specified & as directed.
125Supply and fixing in repairs front grill for desert cooler of approved make complete with 5 Amp switch, three speed regulator including indicator lamp complete all as specified and directed.
126Supply & fixingin repairs GI wire mesh for desert cooler pad.
127Supply & fixing in repairsPVC pipe for connecting pump and water distributor of size 15 mm complete all as specified & as directed complete all as specified and directed.
128Supply & fixingin repairsPVC elbow for desert cooler of suitable size complete all as specified & as directed.
129Supply & fixingin repairs PVC 4 Way distribution cross for desert cooler complete all as specified & as directed.
130S&Fin repairs flexible copper conductor cable, 3 corePVC insulated & PVC sheathed of size 1.5sqmm complete all as specified and as directed.
131S&F in repairs desert cooler fan blade of 18 inch sweep of plastic bodycomplete all as specified & as directed.
132-ditto- all as per item No 102 here-in-before but 20 inch sweep complete all as specified & as directed.
133Supply and fixing in repairs side panel of desert cooler of 20” sweep made out with GI sheet of 20 SWG duly painted with two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer complete all as specified & as directed
134Supply and fixing in repairs switch piano, flush type, single pole, one way 5Amp / 6 Amp 230 V for desert cooler complete all as specified & as directed.
135Supply and fixing in repairs 3 pin plug top 5 Amp, 230V for desert cooler complete all as specified and directed
136Supply and fixing in repairs 3 pin plug top 15 Amp, 230V for desert cooler complete all as specified and directed.
137Supply and fixing in repairs cooler fan motor bracket sets made up as existing includingpaintingcomplete all as specified and directed.
138S&F in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 20 SWG PGI Sheet alongwith PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e, side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with "GE (U) P&M (MES)" letter size of 50mm height in stencil in black/white complete all as specified and as directed.
139Disconnecting from mains and taking downfor servicingof Aqua guard and RO water purifier of Capacity 20 to 50 LPH including detecting the leakage of water and refilling,cleaning of unserviceable items including checkingthe serviceability of electrical/electronic circuits relays, wiring kit, etc., andkeepingthe Aqua guard and RO system unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed. Note :- 1. Replacement of defectivespares for making the Aqua Guard and RO units in satisfactory working condition will be measured & paidseparately under relevant items as "Supply only" and Labour charges for taking out old spares and fixingof new sparesshall deemed to be included in unit rate quoted.
140Supply onlyfollowing new spare parts of Aqua guard and RO water purifier of 20 to 50 LPH capacity:-
141Circuit plate PCB for RO water purifier complete all as specified and as directed.
142Compact switch for RO water purifier complete all as specified and as directed.
143Carbon block for RO water purifier complete all as specified and as directed.
144Candle filter for RO water purifier complete all as specified and as directed.
145Cuno candle for RO water purifier complete all as specified and as directed.
146SV valve for RO water purifier complete all as specified and as directed.
147UV tube for RO water purifier complete all as specified and as directed.
148Membrane for RO water purifier complete all as specified and as directed.
149Pump K48 for RO water purifier complete all as specified and as directed.
150Adopter 48/24 volts for RO water purifier complete all as specified and as directed.
151SS fittings (diverter valve) for RO water purifier complete all as specified and as directed.
152Sediment filter for RO water purifier complete all as specified and as directed.
153Carbon filter (Impoted) for RO water purifier complete all as specified and as directed.
154Adopter 36/24 volts for RO water purifier complete all as specified and as directed.
155Adopter kent 24 volts SMPS for RO water purifier complete all as specified and as directed. Note for item No 111.01 to 111.15 :- Labour of item No 111.01 to 111.15 to be incorporated in item No 110 here-in-before
156Supply and fixing in repairs of 15mm dia PTMTball valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (Minimum weight 142 gms)complete all as specified and as directed.
157Disconnecting and taking down faulty and defective Servo Voltage Stablizers of capacity 1000 KVA , 418 Volts from Plinth with the help of Hydra (Crane) and transporting to Contractor"s workshop from DGIS and opening the top cover of the servo stablizer, carrying out the repairs /works listed at serial No. (i) to (xii) and transporting back to the site (DGIS) for installation including making all the electrical connections complete all as specified and as directed. (i)Decanting of the Servo Volatge Stablizer oil (Transformer Oil)into separate Container /barrel. (ii)Taking out the core/coil of Stablizer (iii)Painting inside of the Stablizer Tank with yellow paint and outside body with synthetic enamel paint of existing tint/colour Cleaning inside of the Stablizer using Stablizer oil. (iv)Fixing only the existing/new buck boost transformer & Dimmer (Variable Transformer) in Stablizer including heating up the core assembly to remove moisture after carrying out the repair works . (v) Renewal of rubberised gasket set for top cover, Brass spindles, LT bushes, etc. (vi)Filling of new Stablizer oil after centrifuging and testing for requird di-electric strength. (vii)Re-fixing the top cover of the stablizer with nuts, bolts and washers. (viii) Preparing Inspection report for renewal of parts etc in presence of EIC and Contractor. (ix)The contractor shall arrange factory visit for the EIC or his representative as and when requried, testing of stablizer to be done on full load at factory. (x) Soldering/ brazing or connecting LV bus bars with sutable size nuts, bolts and washers (xi)Providing necessary insulation papers, sleeves, PVC pipes insulation sheet etc. (xii)Renewal of worn out nuts, bolts and washers. (xiii) Disconnecting the existing old unserviceable On Load Change over switch and fixing new switch. (Note :-Stablizer Oil, Centrifuging of Oil, On Load Change Over Switch & buck boost transformer & Dimmer (Variable Transformer) shall be measured and paid separately under relevant items)
158-ditto- All as item No. 113 above but of capacity 600 KVA
159-ditto- All as item No. 113 above but of capacity 250 KVA
160Supply only buck boost transformerforServo Voltage Stablizer for 1000 KVA.
161Supply only buck boost transformerforServo Voltage Stablizer for 600 KVA.
162Supply only buck boost transformerforServo Voltage Stablizer of capacity 250 KVA.
163M&L for reconditioning of buck boost transformer of Servo Voltage Stablizer of capacity 1000 KVA complete all as specified and as directed.
164M&L for repair to Dimmer (Variable transformer) of Servo Voltage Stablizer complete of capacity 1000KVA complete all as specified and as directed.
165M&L for repair to Dimmer (Variable transformer) of Servo Voltage Stablizer complete of capacity 600KVA complete all as specified and as directed.
166M&L for repair to Dimmer (Variable transformer) of Servo Voltage Stablizer complete of capacity 250KVA complete all as specified and as directed.
167Supplyand fixing in repairs Servomotor synchronus motor for Servo Voltage Stablizer of capacity 1000 KVA including takingdown old unserviceable burnt motor complete all as specified and as directed.
168Supplyand fixing in repairs Servomotor synchronus motor for Servo Voltage Stablizer of capacity 600 KVA including takingdown old unserviceable burnt motor complete all as specified and as directed.
169Supplyand fixing in repairs Servomotor synchronus motor for Servo Voltage Stablizer of capacity 250 KVA including takingdown old unserviceable burnt motor complete all as specified and as directed.
170Supply only On Load Manual Changeover Switch Disconnector 1600 A, Open Execution, 4 Pole, 415 V AC, suitable for fixing with the existining Servo Volatge Stablizer of 1000 KVA Capacity.
171M&L for on line Dehydration/filteration of Servo Voltage Stablizer oil including filteration using automatic centrifuging machine minimum three cycles to achieve dielectric strength 40 to 60 KV breaking capacity at 2.5mm gap by absorbing and abolishing all sludge particles as per BS-66-1963 including topping up with new transformer oil as required complete all as specified and as directed. Note- (i)Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arrange by contractor. (ii) Oil required for topping up the stablizer will be measured & paid separately as supply only under respective item of this Sch.
172Supplying and filling/topping up transformer oil low viscocity, dielectric strength 35 to 40 KV breaking voltage for topping up servo voltage stablizers duly centrifuging including filter action by using automatic centrifuging machine to achieve min 35 to 40 KV breaking capacity at 4 mm gap by absorbing and abolishing all sludge particles for use as per BS-B-66-1983 complete all as specified and as directed..
173Disconnecting from mains/taking out existing unserviceable/defective Servo Voltage of capacity 10 KVA of any size, type, and make removing from foundation transporting to repair workshop drain out old stablizer oil, taking out core taking out the unserviceable burnt out transformer, re-winding with super enameled copper wire of existing size applying proper insulation,varnish drying in oven,painting inside of the Stablizer Tank with yellow paint and outside body with synthetic enamel paint of existing tint/colour assembling and filling up the transformer oil transporting back to site, re-installating, testing and commissioning complete all as specified and as directed. (i) Oil required for filling in the stablizer shall be measured & paid separately as supply only under respective item of this Sch.
174Collecting of unserviceablevoltage stabilizerof capacity 2 to 5 KVA from the MES store yard of AGE E/M (AC) or dismantlingthe same from site and transporting to contractors workshopfor locating the fault includingcheckingthe serviceability of electrical/electronic circuits relays andreplacement of defective spare parts , reassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to MES store yard complete all as specified and as directed. Note :- 1. Replacement of defectivespares and rewinding of transformer of voltage stabilizerwill be measured & paidseparately under relevant items and Labour charges for taking out old spares & fixing of new sparesshall deemed to be included in unit rate quoted.
175Supply onlyfollowing new spare partsof Voltage stabilizerofcapacity 2 to 5 KVA :-
176Voltmeter (Analog) 0 to 300 volts any type shape single phase 50 Hz AC supply.
177Digitaltype Voltmeter0 to 300 volts any type shape single phase 50 Hz AC supply.
178Printer circuit control card for 2 to 5 KVA voltage stabilizer
179Input/output switch.
180Push on switch.
181Indicator with neon bulbs.
182Trigger Transformer for 2 to 5 KVA voltage stabilizer
183Relay for 2 to 5 KVA voltage stabilizer.
184Time relay and High/low voltage cut off circuit with relay suitable for 2 to 5 KVA voltage stabilizer Note for item Nos 131.01 to 131.09 :- Labour of item Nos 131.01. to 131.09 to be incorporated in item No 130 here-in-before
185Taking out the burnt winding of transformer of voltage stabilizer and preparing core after cleaning by suitable cleaning agent and rewinding the transformer of voltage stabilizer with super enameld copper wire of existing gauge including varnishing, heating and refitting of capacity 3KVA voltage stabilizer, complete all as specified and as directed.
186-ditto- all as per item No. 132 here-in-before but 4 KVA complete all as specified and as directed.
187-ditto- all as per item No. 132 here-in-before but 5 KVA complete all as specified and as directed.
188Disconnecting all electrical connections of existing unserviceable voltage stablizers of any make and capacity and Supply, Installation & commissioning in repairs new voltage stabilizers for automatic operation single phase naturally air cooled indoor type with copper wounded transformer designed for input variation between 160 Volts to 260 Volts with output voltage stablized at 230 Volt with accuracy + 9% with time delay facility and of capacity 4.0 KVA complete all as specified and as directed.
189Disconnecting all electrical connections of existing unserviceable voltage stablizers of any make and capacity and Supply, Installation & commissioning in repairs new voltage stablizers for automatic operation single phase naturally air cooled indoor type with copper wounded transformer designed for input variation between 160 Volts to 260 Volts with output voltage stablized at 230 Volt with accuracy + 9% with time delay facility and of capacity 5.0 KVA complete all as specified and as directed.
190Supply & fixing PVC insulated 4 core copper conductor cable of size 4 sqmm for connections in LT Panels including copper thimbles including taking down old unserviceable onecomplete all as specified and as directed.
191-ditto- all as per item No. 137 here-in-before but of size 6 sqmm three core complete all as specified and as directed.
192Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level,connected to the galvanised earth lead 25x4mm by means of bolts, nuts check nuts and washers of galvanised iron wire 4mm as earth lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation andearth work insoft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregatepit, funnel,20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including taking down old unserviceable one complete all as specified and as directed. Note:- Each protection pipe and earthing lead upto and including 7.5 meter length is deemed to be included in the qouted rate of this item.
193Supply and fixing earth continuity conductor or main earthing lead (GI strip) of size 25 x 4 mm fixed to plinth or buried in ground or drawn in GI pipe or any other situation as indicated for loop earthing etc including taking down old unserviceable one complete all as specified and as directed.