Supply, Installation, Testing And Commissioning Of Mri 3T Scan System Along With Required Turnkey Works. Supply, Installation, Testing And Commissioning Of Mri 3T Scan System Along With Required Turnkey Works. , Cat (A) -Supply, Installation, Testing And , kharghar-Maharashtra

Tata Memorial Centre has published Supply, Installation, Testing And Commissioning Of Mri 3T Scan System Along With Required Turnkey Works. Supply, Installation, Testing And Commissioning Of Mri 3T Scan System Along With Required Turnkey Works. , Cat (A) -Supply, Installation, Testing And . Submission Date for this Tender is 17-08-2022. Dustbin Tenders in kharghar Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

32137972
Corrigendum : Supply, Installation, Testing And Commissioning Of Mri 3T Scan System Along With Required Turnkey Works. Supply, Installation, Testing And Commissioning Of Mri 3T Scan System Along With Required Turnkey Works. , Cat (A) -Supply, Installation, Testing And
Open Tender
Indian
Maharashtra
kharghar
17-08-2022

Tender Details

Supply, Installation, Testing And Commissioning Of Mri 3T Scan System Along With Required Turnkey Works. Supply, Installation, Testing And Commissioning Of Mri 3T Scan System Along With Required Turnkey Works. , Cat (A) -Supply, Installation, Testing And Commissioning Of Mri 3T Scan System As Per Tendered Specifications At Actrec, Kharghar, Navi-Mumbai Quantity – 1 No. , Supply, Installation, Testing And Commissioning Of Mri 3T Scan System As Per Tendered Specifications At Actrec Kharghar, Navi-Mumbai , Cat (B) - Turnkey Works Required Forinstallation, Testing And Commissioning Of Mri 3T Scan System At Actrec Kharghar, Navi-Mumbai , Civil Work , Dismantling Existing Brick Masonary With Plaster,Tile Etc Complete Including Required Scaffolding Etc Complete , Removing Existing Tile Flooring And Loose Material Below Tiling , Removing Existing Dado Tile And Loose Material , Removing Existing Plaster , Removing Existing Doors,Windows And With Frame , Removing Of Existing Ducts Handing Over To Department , Removing Of Existing Light,Power Pooints,Wiring Etc Handing Over To Department , Carting Away Debries Outside Hospital Premises To Permitted Location As Per Existing Norms Of Dumping. Capacity Of Each Truck Load Will Be Calculated Against Each Gate Bass Issued By Actrec. , Providing And Laying6 Brick Wall In Cement Mortar 1:6 , Providing And Laying4 Brick Wall In Cement Mortar 1:6 With Patly In Concrte And Stell @ 4Feet Height , Providing And Laying Factory Made Precast Concrete Solid Blocks Of 100Mm/150Mm/200Mmthickness Of Grade M10 Grade In Superstructure Above Plinth Level Up To Floor V Level In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Providing 12Mm Tk Cement Plaster In Cm 1:6 , Providing And Applying3 Or More Coats Of Plastic Emulsion Paint On Walls As Per The Manufacturers Directions Including Scaffolding Etc. Complete. , Providing And Applying Vement Based Wall Putty Minimum 2Mm Thick , Wall/Floor Chasing (Upto 200 Mm Thick Concerete ) , Trench Work As Perdrawing Cutting Down Floor Finishing With Tiles At Bottom Side And Covering With Ply And Tile On Top Removable Type , Supply And Laying Concrete M20 Flooring,Lintels,Slabs At All Heights , Reinforcement For Reinforced Cement Concrete At All Floors And Levels Including Supplying Cutting Bending Fixing And Binding In Position With 1.6Mm Dia Soft Drawn Annealed Binding Wire Including Cost Of Binding Wire Labour Etc. Complete All As Per Specifications And As Directed By The Engineer-In-Charge. (Laps Will Not Be Measured). With High Yield Strength Deformed Bars (Tmt Bars) & Ms Round Bars , Supply And Fixing 35 Mm Thick Flush Door Panel With 1Mm Thick Laminate Both Sidewith Hinges,Aldrop,Door Closer,Door Stopper Etc Complete , 1.5Mx2.1M , 1Mx2.1M , 0.8Mx2.1M , Supply And Fixing Of Door Frame Teak Wood 125Mm X 100Mm Size 1St Class Teak Wood With T.W. Moulding Of 75 X 12Mm On Wall & Frame Junction. , 1.5Mx2.1M , 1Mx2.1M , 0.8Mx2.1M , Fixing Door Frame : Fixing Available Wooden Frame Workfor Door/Windows Of Any Size By Providing M.S. Hold Fastof Size 40Mm X 3Mm X 150Mm Long Bend To Shape Andexternal Face To Be Painted By Two Coats Of Bitumestic Paint. Filling The Gap With Brick Work /Cement Concrete By Side Finishing Plastering And Making Good The Same Tc. Complete. , Removing & Re-Fixing Available Door Shutter With Necessary Modification Including Cutting The Existing Shutter Providing Leeping Patti All Around The Shutter If Required Including Removing & Refixing Availbale Old Hinges, Mortice Lock, Tower Bolts Ect. Fixing Aligning The Door Shutter In Proper Plumb And Level Etc. Complete All As Per Specified And Directed By Engineer-In-Charge , Supply And Fixing Sliding Window With Glass,Film,Aluminium Section, Track Etc Complete , Removing Of Old False Ceiling , Providing And Fixing Tiled Metal False Ceiling Of Size 595X595mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams/ Sqm, Both Side Inclusive) Consisting Of Main “T” Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross “T” Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main “T” At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross “T” Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main “T” Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All Tsections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge.Gi Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of Aluminum Sheet Having Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending. , Providing And Fixing 2Mm Thick Vinyl Floor,With Surface Preparation ,Pasting Etc Complete , Providing And Fixing Acp Wall Paneling With Aluminium Faming ,Pasting Etc Complete , Supply & Fixing Vetrified Tile 600Mmx600mm Flooring & Skirtingover Sand Cement Cm 1: 6 Bedding. , Providing Fixing Trap Door In Min 2Mm Thick Acp With Aluminum Framing Supported With Necessarry Ms Struructreetc Complete As Directed And Instructed. , Providing & Fixing 46Mm Thick Fully Flush Double Skin Fire Door Shutter Of 120 Minutes Fire Rating Confirming To Is:3614(Part 11),Tested & Certified By Nabl Accredated Laboratory Door Frame & Leaf Shall Be Manufactured From 1.6Mm (16 Gauge) & L.2Mm (18Guage) Minimum Thick Galvanised Steel Sheet.The Internal Construction Of The Door Should Be Rigid Reinforcement Pads For Receiving Appropriate Hardware. The Infill Material S~All Be Resin Bonded Honeycomb Core. The Edges Should Be Interlocked With Lock Seam. All Doors Shall Be Finished With Polyurethane Aliphatic Grade Paint Of Approved Colour. The Door Shall Have Passed Minimum 250 Hours Of Salt Spray Test. , Supply And Fixing Gi Chain Link 4Mmm Dia Mesh With Ms Angle Frame Of 50X50x6mm With Flat Forchiller Enclosure With Access Ms Door Complete As Directed And Instructed With 2 Coat Of Enamel Paint Over A Coat Of Metal Primer. , Providing Structural Steel (Mild Steel As Defined In Is 800-2007 Clause 2.2)For Frame Work Of The Proposed Structure Including Fabricating, Cutting, Welding, Rivetting, Bolting, Erection And Oilpainting With One Coat Of Primer And Two Finishing Coats , Providing Corrugated G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Ofsteel Primer And Two Coats Of Enamel Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces), Excluding The Cost Of Purlins, Rafters And Trusses : 0.80 Mm Thick With Zinc Coating Not Less Than 275 Gm/M² . This Includes Ridges, Valleys, Long Line Crimps. , Supply And Fixing Pcc (M25 Grade) Chiller Foundation , Design Detailing Of Chiller Shade , Furniture , Providing And Placing In Position Following Furniture , 1600Mm X 600Mm Work Station Tables With 18Mm Thick Plywood One Drawer And One Storage Shelf With Fully Laminated Of Approved Design And Pattern. , 1800Mmx600 Mm Console Table 18Mm Play Wood With Fully Laminated Finish. , Providing And Placing Revolving Chairs With User-Adjustable Height, Medium Backrest Height, With Hand-Rest Manufactured By Reputed Furniture Co Which Is Widely Used In And Matching Exisitng Design Pattern Complete As Directed & Instructed. , Chairs For Patient Waiting Area Ms Three-Seater Manufactured By Repurted Co And Matching Exisitng Design Patterns Complete As Directed & Instructed. , Providing And Placing Overhead Storage With 18Mm Playwood Fully Laminate Door Shutters For Storageas Per Requirement With Ms Bracket Nicely Designed & Installed Below Storege Units. , Providing And Placing Below Counter Storage With 18Mm Playwood & Fully Laminate Door Shutters,Drawers For Storageas Per Requirement With Granite Top (1800X750)In Mm , Providing And Placing Cupboard With 18Mm Playwood With Fully Laminate Door Shutters For Storage Of Spare Parts, Accessories And Records, As Per Requirement (1800X900x600) , Name Boards For All Rooms Arcylic Matching Existing Design Patterns. , Dustbins (Plastic With Lid) , Change Room Locker Ms Powder Coated With Stand Manufactured By Reputed Co Matching Exisitng Design Pattern Complete As Directed And Instructed. , Curtains With Aluminnum Powder Coated Track With Suspened Supports From Ceiling For Patient Changing, Complete As Directed And Instructed. , Electrical Works , Wiring For 5/15 Amp Poweroutlet With2.5 Sqmm 660/1100V Pvc Insulated, Frls, Copper Conductor Wiresin Recessed/Surface Ms Conduit Including Cost Of Cutting And Filling Chases Supply Andfixing Of6 Pin 16Ampsshuttered Modular Switchsocket, Switch Plate With Internal Wiringin G.I. Box, Earthing Of 3Rd Pin With Pvc Insulated, Green Colour 2.5 Sqmm Copper Wire, Complete With All Accessories As Required. (Power Socket). , One 16A Outletonone Circuit With Switch Socket To Match Existing Design Patterns. , 5A/15Aoutletsonone Circuit With Two Switch Sockets To Match Existing Design Patterns. , Wiring For Radiation Lamo,Emergency Stop,Push Button On Off With Supply Of Switches,And Lamp , Supply And Laying 2.5 Sqmm Light Wiring For Radiation Lamp And Radiation Lamp , Supply And Laying 2.5 Sqmm Light Wiring For Emmergency Stop With Emmergency Stop Supply , Supply And Laying 2.5 Sqmm Light Wiring For Push Button On Off With Push Button On Off Suppy , Supply Installation Testing And Commissioning Of Tpn Mcb Double Door Distribution Boards Dust And Vermin Protected And Rated For 415V.Three Phase Ac Supply Operation Including Incoming Mccb/Mcb/Rcbo As Per Specifications And Required Capacity Neutral Bar And Earth Terminal Complete As Required And Installed In Flush With Wall Including All Fixing Materials Required. Mcbs Shall Conform : 8828 And Rcbo/Rccb Shall Conform To Is : 12640. , 8 Way Tpn Mcb Db With 63A, Tpnmcb As Incomer 3-Nos. 100 A Copper Bus Bars Of Equal Ratings And 24Nos. Sp Mcbas Outgoings . , Supply, Testing & Commissioning Of Factory Finished Powder Coated Modular/ Compartmentalised Panel Fabricated Out Of 14/16 Swg Ms Sheet, Dust & Vermin Proof With Minimum Ip 52(Main Panel) Degree Or Protection, Voltmeter, Meter, Indicating Lamps, Busbars, Terminal Blocks Etc Complete As Required. As Per Single Line Diagram.Tpn/Spn Dbs Shall Have Ip-42 Degree Of Protection, Panel/Dbs Shall Have Space For 20% Addition / Deletion Of Feeders And With Incomer 4C Of 1C Flexible Copper Conductor Of Appropriate Sizevolt Meter ( 0- 500V)- 1No. Ammeter (0-250 Amp)- 1No. Phase Indicator Lamps .All Mccb Microprocessor Type.Busbars 400Amp Tpn Busbar Of Copper Alloy. 400 Amp/ 440V Tp Mccb- 1No. Mains .200 Amp/ 440V Tp Mccb- 1No. To Ups . 200Amp/ 440V Tp Mccb With Contactor- 1No. To Ct. 100 Amp/440V Tp Mccb For Light And Ac100 Amp/440V Tp Mccb For Chiller , 3.5 Core 150 Sqmm Aluminum Armoured Cable With End Termination , Supply And Fixing Galvanised Cable Tray 900Mm Wide , Supply, Laying In Trenches/On Trays/ On Racks/ On Wall/ Structure, Testing & Commissioning Of The Pvc Insulatedflexible Copper Conductor Power Cables Of The Following Sizes Complete As Required Including Cable Marker And End Termination With Brass Compression Gland And Copper Lugs Etc. , 1Cx 95 Sq Mm Flexible Copper Wire And End Termination , 1Cx 70 Sq Mm Flexible Copper Wire And End Termination , 4Cx10 Sqmm Flexible Copper Wire For Db , 4Cx16 Sqmm Flexible Copper Wire For Chiller , 4 Sqmm Copper Insulated Flexible , 2.5 Sqmm Copper Insulated Flexible Wire , 1.5 Sqmm Copper Insulated Flexible Wire , Wiring For 6A 5/6 Pin Lightpoint With 1.5 Mm2 660/1100V Pvc Insulated, Frls,Copper Conductor Cable In Recessed Ms Conduit Including Cost Of Cutting And Filling Chases As Required With Fixing Of Plate, Gi Box, 6A Modular Switch Shuttered Socket And Earthing Complete With All Accessories As Required (First Point Shall Be Wired From 2.5 Mm2660v Grade Pvc Insulated Copper Wires & Looping With 1.5Mm2). , Supply And Fixing Mr Compatible Led Lights To Match Existing Design Patterns. , Providing Lights With Fitting 600Mmx600mm Led Type 40W To Match Existing Design Patterns. , Supply And Fixing Data Points Rj45 , Supply And Fixing For Telephone Points Rj45 , Supply And Laying Network Cable Cat 6 Supply Fixingconduiting Complete , Supply And Laying Telephone Cable Cat 6 Supply Fixingconduiting Complete , Supply And Providing Network Switch 16 Port , Supply And Providing Electrical Point For Split Ac6 Sqmm Cable Pahse Neutral Earthingfrom Db Up To Ac And Its Switch Socket , Providing Earthing Pit Copper Earthing Chemical Typewith Bore And Conductor Or Conventional Type With Pit Salt,Coal , Laying Earthing Conductor From Earthpit To Ups ,Electrical Room , Two Door Interlock System With Controller, In/Out Ss Pb, Em Lock, Door Position Sensor, Emergency Release Switch, Control And Signal Cable, Etc. , Sitc Of 2 Runs 3.50 X 150 Sq Mm Aluminum Armoured Cabel From Sub Station To Mri Inclduing Excavation, Back Filling Dismantling Concrete Making Good Surface Complete As Directed & Instructed. , Sitc Of 400 A Tpn Mccb With Enclosure. , Termination Of 3.50 X 150 Mm For Aluminum Armoured Cable As Directed & Instructed. , Fire Fighting System , Addressablesmoke Detector , Conventional Hotter With Flasher , 2 Zone Fire Alarm Panelinbuilt Power Supply Battery Charger & Battery Backup Relay Interface (Common Fire) , 2X1.5 Sqmm Copper Cable Armoured , Response Indicator , Fire Extinguisher 5Kg , Mr Compatible Fire Extinguisher , Hvac Work , Uninstalled Existing Hi Wall Ac Including Indoor, Outdoor Units, Copper Piping, Cables Etc From Reporting Room, Consultant Room Console Room Etc As Per Instruction And As Directed By Oic-Es. , Reinstalltion And Commissioning Of Above Mentioned Units As Per Instruction And As Directed By Oic-Es , All Refrigerant Piping Shall Be Of Copper, Complete With Supports Between Indoor & Outdoor Units Duly Insulated With 13Mm Nitrile Rubber Insulation.Rmt Indicated Is For Set Of Piping Between Indoor And Outdoor Machine, Individual Piping Will Not Be Measured. , 1/2,1/4 Or Equivelant To The Units , 5/8,3/8 Orequivelant To The Units , Sitc Pvc Drain Pipe Having Pressure Holding Of 6Kg/Cm2 Drain Piping Complete With All Accessories With 6Mm Nitrile Rubber Insulation 25 Mm Dai , Sitc Control Cables Between Indoor And Outdoor Unit And To The Main Supply Cables As Per Instructed And As Directed By Oic-Es.All Exposed Cable Should Be Laid In Ladder Type Tray , Central Ac , Design, Supply, Fabrication And Installation Of G.S.S. Ducting With Volume Control Dampers On Every Branch If There Is, Powder Coated Supply/Return Air Diffusers With Required Hardware’S, Supports, Wooden Frame And Painting On Ducts, Ms Parts Etc With Acoustic Insulation 19 Mm(Supply)/13 Mm(Return)Nitrile Rubberinsulation As Per The Smacna Standard, Approved Drawings And Instructions Of Engineer-In-Charge With The Following Gauges. Note:- All Exposed Duct Insulation Should Be With Al Cladding. , 24 Gauge G.S.S. Rectangular Duct With Necessaryinsulation And Metallic Foil. , Dismatling Of Existing Duct With All Necessary Hardeware As Per Instruction And As Directed By Oic-Es , Grills And Damper , Sitc Of Extruded Aluminium Powder Coated Diffuser/Grill With Volume Control Damper With All Necessary Supports As Per Directed And As Instructed By Oic-Es , Sitc Of Extruded Aluminium Powder Coated Diffuser/ Grill Without Volume Control Damper With All Necessary Supports As Per Directed And As Instructed By Oic-Es , Sitc Of Dehumidifier With Capacity Of 50L/Day. , Mgps Works , Copper Pipes Specifications Of Mgps System Medical Gases Supply System Distribution Piping Copper Pipeline.The Piped Distribution System Must Use Copper Pipes Manufactured From Phosphorus Deoxidized Non Arsenical Copper. All Pipelines Used Along With Flow Meter Etc. Should Be Isi Mark Preferably Size, , 12Mm & 15 Mm And Thickness Of 0.7 & 0.9Mmshould Be Drawn, Seamless, Deoxidized, Nonarsenical, Half-Hard Tempered And Degreased Materials Conforming To Bs6017/1981 And Manufactured As Per Bs-2871/The New European Standard En 1057.All Copper Pipes Are To Be Certified By Authorized Test House Services For Physical Properties And Chemical Properties.Copper To Copper Joints Shall Be Made On Site Using A Silver Copper Phosphorus Brazing Alloy. Copper To Brass Or Gun Metal Joints Shall Not Be Made On Site.Pipe Lines Should Be Supported At The Intervals Specified In Htm 2022 Using Suitable Metallic, Non Ferrous Material. Plastic Supports May Be Used Only For The Drown Drops To The Terminal Units.Fitting Shall Be End Feed Type, Manufactured From The Same Grade Of Copper On The Pipes.Fittings Shall Be Degreased Suitable For Oxygen Use And Supplied Sealed In Protective Bags , 12Mm Pipeline , 15Mm Pipeline For Oxygen , High Pressure Tubing , Non Magnetic Connector , Medical Gas Outlets Non Magnetic Bs Standard And Duly Ce Marked. Medical Gas Outlets With Probes. , Self Sealing Valve Outlet For Oxygennon Magnetic , Self Sealing Valve Outlet For Vacuum Non Magnetic , Isolation Valve :-15 Mm Isolation Valve With Suitable Fittings , Handle Without Teflon Tape. Easy To Close And Operate , Oxygen Flow Meter With Humidifier Bottle , It Should Have Humidifying Bottle With Whole Flow Meter Assembly, Should Be Of Light Weight Material. It Should Have Backpressure Compensated Flow Meter. It Should Provide Accurate Gas Flow Measure By 0-15 Liter/M Flow Meter. Flow Tube Should Be Of Good Quality, Transparent With Measuring Humidifying Bottle. Flow Meter Should Be Fitted With Matching Adaptor (Probe) For Oxygen Outlet Point , Ward Vacuum Unit , It Should Include Vacuum Pressure Regular Up To 760 Mm Hg With Dial Gauge . Should Have Re-Usable Collection Bottle 1000 Ml Made With A Wall Bracelet. Or Unbreakable Polycarbonate Materials, Fully Auto-Clavable Along With Safety Device To Prevent Overflow And With A Wall Bracetk. Should Be Wall Mounted And Back Flow Resistance Should Have 600Ml Capacity With Play Contracted Jar The Controller Should Be Operated By Means Of A 180 Degree On/Off Switch And A Bonnet Adjustment , Cat (B) - Buy Back Items , Buy-Back (Ie Minus)Amount Of Old Mri System At Actrec Kharghar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Jun-2022 EXTENSION OF DUE DATE Date 22-06-2022
2 16-Jun-2022 2CORRIGENDUM Date 04-07-2022
3 04-Jul-2022 Due Date Extension Date 14-07-2022
4 12-Jul-2022 Modification in Technical Specification Technical Bid 28-07-2022
5 12-Jul-2022 Due Date Extension 2 Date 28-07-2022
6 27-Jul-2022 Due date extended Date 08-08-2022
7 03-Aug-2022 Technical Specification modified Technical Bid 08-08-2022
8 06-Aug-2022 Due date extension Date 17-08-2022

Key Value

Document Fees
Refer document
EMD
INR 500000.0 /-
Tender Value
Refer document