Textiles Statutory Bodies & Commissions/Committees Closing in 0 days TDR #32127743

Work Of Electrification For Garment Making Centre At Payynnur In Kannur District

Issued by Statutory Bodies & Commissions/Committees · kerala, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 May 2022
0 days left
EMD
12800
Bank guarantee accepted
Document Fee
1200
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kerala → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Work Of Electrification For Garment Making Centre At Payynnur In Kannur District

BOQ

Name of Work: Work of Electrification for Garment Making Centre at Payynnur in Kannur DistrIct
Sl. No. Item Description
1APPENDIX-A
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.GROUPA ( D S RELECTRICAL1.10.1)
3Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). ( D S RELECTRICAL1.31)
4Wiring for Twin controllight pointwith 1.5 sq.mm FRLS PVC insulated copper conductor singlecore cable in surface / recessed medium class PVC conduit,with2Way modular switch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable etc. as required. ( D S RELECTRICAL2016 1.11)
5Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)( D S RELECTRICAL1.27.1)
6Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)( D S RELECTRICAL1.27.2)
7Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12Module (200mmX150mm)(D S RELECTRICAL1.27.6)
8Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch(D S RELECTRICAL1.24.1)
9Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TwoWay 5/6 amps switch(D S RELECTRICAL1.24.2)
10Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch( D S RELECTRICAL1.24.3)
11Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet(D S RELECTRICAL1.24.4)
12Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet(D S RELECTRICAL1.24.5 )
13Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(D S RELECTRICAL1.26)
14Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 MM( D S RELECTRICAL1.21.1)
15Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25MM( D S RELECTRICAL1.21.2)
16Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm (D S RELECTRICAL1.17.3)
17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm(D S RELECTRICAL1.17.12)
18Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm( D S RELECTRICAL1.17.21)
19Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4x 6 sq. mm( D S RELECTRICAL1.17.31)
20Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 6 way,( 4+18) Double door(D S RELECTRICAL2.4.2 )
21Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SinglePole( D S RELECTRICAL2.10.1)
22Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required (D S RELECTRICAL2.11)
23Supplying and fixing following rating,Four pole,415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps(D S RELECTRICAL2.13.2)
24Supplying and fixing following rating,Four pole, ( Three phase and neutral), 415volts, Residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63Amps(D S RELECTRICAL2.15.3.)
25Supply , conveyance, installation, testing and commissioning Wall mounting fan of400mmSweep withOscillation systemand Pull Cord, using mounting brackets supplied along with the fan and giving connection with existing wire.
26Supply, conveyance installation testing and commissioning ofSleekCompactSURFACE Mounting LEDSlimPanellight fitting 12 W , square or round,Cool orWarm,size 155 mm ( or nearest availablesize)with light Weight Body,energy efficient drive ,complete with all accessories , fixingdirectly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required.
27Provision for cable trayworkSupplying and fixing cable tray including all cost

AI Tender Summary

OUR REF NO 32127743
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 16-05-2022
Authority
Authority Name Kerala Khadi And Village Industries Board
Work Description Work Of Electrification For Garment Making Centre At Payynnur In Kannur District
Basic Detail
Tender No KB.801/2022/Engg
Bidding Type Tender
Location
City kerala
State Kerala
Key Dates
Publish Date 07 May 2022
Submission Date 16 May 2022
Open Date 18 May 2022
Finance
Tender Value Ref. Documents
Tender Fee 1200
EMD 12800
Exemption Not Available
Document List
Tendernotice_1.pdf
Tendernotice_2.pdf
1e763d4f-e852-495c-832a-59438435f027.html
BOQ_702926.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 07, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
May 16, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 18, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

html

1e763d4f-e852-495c-832a-59438435f027.html

xls

BOQ_702926.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders