}

System Design, Engineering, Manufacturing, System Design, Engineering, Manufacturing, Supply, Eandc Pg Test Etc. Of Conveyor Package Including Lhp And Ghp For 3X800mw Patrathu Tps, Jharkhand. , Supply Part Comprising Of Design ( I.E. , Jharkhand-Jharkhand

Boards / Undertakings / PSU has published System Design, Engineering, Manufacturing, System Design, Engineering, Manufacturing, Supply, Eandc Pg Test Etc. Of Conveyor Package Including Lhp And Ghp For 3X800mw Patrathu Tps, Jharkhand. , Supply Part Comprising Of Design ( I.E. . Submission Date for this Tender is 16-05-2022. clocks Tenders in Jharkhand Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

32109977
System Design, Engineering, Manufacturing, System Design, Engineering, Manufacturing, Supply, Eandc Pg Test Etc. Of Conveyor Package Including Lhp And Ghp For 3X800mw Patrathu Tps, Jharkhand. , Supply Part Comprising Of Design ( I.E.
Open Tender
Indian
Jharkhand
Jharkhand
16-05-2022

Tender Details

System Design, Engineering, Manufacturing, System Design, Engineering, Manufacturing, Supply, Eandc Pg Test Etc. Of Conveyor Package Including Lhp And Ghp For 3X800mw Patrathu Tps, Jharkhand. , Supply Part Comprising Of Design ( I.E. Preparation And Submission Of Drawing / Documents Including As Built Drawings And O&M Manuals ) , Engineering, Manufacture, Fabrication, Assembly, Inspection & Testing At Vendors & Sub-Vendors Works, Painting, Maintenance Tools & Tackles, Mandatory Spares , Spares For Erection, Startup And Commissioning As Required, Fill Of Lubricants & Consumables And Till Cod Of The Units, Forwarding, Proper Packing, Shipment And Delivery At Site For Project And Package Complete With All Accessories For The Total Scope Defined As Per Bhel Nit & Tender Technical Specification, Amendment & Agreements Till Placement Of Order. , Coal Handling Plant , Complete Conveyor System ( 3500 Mtph Rated / 3850 Mtph Design, 2000Mm Belt Width, Belt Speed Of Conveyors Shall Not Be More Than 3.4 M / S Complete With Idlers ( With Frames, Brackets ) , All Types Of Pulleys With Plummer Blocks And Bearings, Deflector Rollers, Drive Chain System ( Gear Boxes, All Types Of Fluid Couplings ( Fluid Coupling, Scoop Coupling, Flexible Coupling, Geared Couplings, Other Input And Output Couplings ) , Brakes, Technological Structures, Including Gtu Towers ( Other Than With Tps And Conveyor Trestles ) , Gtu Travel Guide Pipes, Ci Counter Weights ( If Applicable ) , Cradles, Short Supports, Stringers, Stools, Skirt Board And Skirt Rubber, Deck Plates Throughout Conveyor Length , Maintenance Platforms, Inspection Doors, Inspection Stools, Ladders, Bolts, Anchor Fasteners, Templates, External Scrappers, Internal Scrappers, Foundation Bolts & Nuts, Rubber Sealing, Drive Base Frame, Base Plate, Shim Plate Etc. With All Electricals And C&I ( Except For Items Indicated Separately Under Electrical , C&I As Per Electrical Scope ( Section D Of This Spec. ) , Nylon-Nylon Belt For Conveyors ( As Applicable ) , With Splicing Kit As Per Requirement And Specification , Steel Cord Belt For Conveyors ( As Applicable ) , With Splicing Kit As Per Requirement And Specification , Complete Reversible Belt Feeders In Crusher House ( 2400 Bw, 20 Deg Troughing Idler Angle At 1.5 M / S Max. Speed ) Rated 1750Tph / Design 1925 Tph ( Including Supply Of Belt ) With All Electricals And C&I. , Complete Belt Feeders In Crusher House ( 2400 Bw, 20 Deg Troughing Idler Angle At 1.5 M / S Max. Speed ) Rated 1750Tph / Design 1925 Tph ( Including Supply Of Belt ) With All Electricals And C&I. , Inline Magnetic Separators With Belt, Drives, Fixing Lugs, Slings, Fixing Accessories, Tramp Iron Chute Up To Ground Level, Reject Trolley And With All Electricals And C&I Etc. , Metal Detectors Along With All Electricals And C&I. , Suspended Magnet Along With Fixing Lugs, Slings, Fixing Accessories, Tramp Iron Chute, Reject Trolley All Electricals And C&I. , Belt Weighers Along With All Electricals And C&I. , Chutes With Chute Support Structure, Chute Block Switches In Building & Tunnel, Transfer Points, Crusher House, Wagon Tippler Complex, Track Hopper Complex Etc. Including Liners In Crusher Supporting Rcc Deck, Tramp Iron Chutes Upto Ground Level And With All Electricals And C&I. , Complete Travelling Tripper Machine With Drives, Flap Gates ( Motorized ) With Actuator, Two-Way Chute, Including Supports, Rails, Rail Fixtures, Clamps And Other All Electricals And C&I, Drives & Accessories. Rated 3500 Tph / Design 3850 Tph ( For Drives Geared Motors Are Not Acceptable, So Bidder To Provide Conventional Electro Mechanical Drive I.E. Gearbox, Brake And Motor ) . Drive Rating Shall Be Min. 2 X 50 %. , Bunker Sealing Arrangement Complete With Idlers, Tensioning Arrangement, Etc. ( Including Supply Of Belt ) . , Complete Coal Sampling Unit At Crusher House, ( - ) 250 Mm , Occasional 400Mm Uncrushed Coal With All Electricals And C&I. , Complete Coal Sampling Unit At Tp-5, ( - ) 20 Mm Crushed Coal With All Electricals And C&I. , Flap Gates With Motorized Actuator Including Limit Switches, Fixing Supports, Maintenance Access And All Electricals And C&I. , Rack And Pinion Gates With Actuators, Fixing Supports, Maintenance Access And All Electricals And C&I. , Rod Gates, Fixing Supports, Maintenance Access. , Fixed Trippers With Belt Guards And Other Accessories. , Electrical Hoist With All Electricals And C&I For Entire Chp, Lhp & Ghp Transfer Points, Storage Sheds, Crusher House , Bunker Floors, Gtu, Wagon Tippler Complex, Track Hopper Complex, Pump Houses Etc. , Manual Hoist With Travelling Trolley And Chain Pulley Blocks For Entire Chp, Lhp & Ghp Transfer Points, Storage Sheds, Crusher House , Bunker Floors, Gtu, Wagon Tippler Complex, Track Hopper Complex, Pump Houses Etc. , 3 Ton Capacity Motorised Electric Winches At Ba Tp-5 For Gtu With All Electricals And C&I. , Sump Pumps Including Discharge Piping Valves, Accessories & Support Structure Along With All Electrics And C&I For Entire Chp, Lhp & Ghp. , 1000Kg Rope & Sheave Type Passenger Cum Goods Elevator Shall Be Provided Along With Electricals And C&I For Crusher House And Tp-5 ) . The Elevator Shall Be Designed As Per Clause No 5.17.0 And Data Sheet Of Elevator Of Sub Section-A-23, Of Part B Of Technical Specifications , Belt Vulcanizing Machine With Tool Kit For 2400Mm Belt Width With All Accessories, Consumables, Etc. With All Electricals And C&I. , Complete Online Coal Analyzer All Electricals And C&I. , Radiation Survey Meter , Complete Venturi Scrubber Type Wet Dust Collection System For Vibrating Feeder And Reversible Belt Feeders After Crusher In Crusher House With All Electricals And C&I. , Complete Manual Stone Picking Arrangement Along With Chutes & Other Accessories. , Rails & Rail Fixtures For Coal & Limestone Paddle Feeder Machine ( 1750Tph ) In Chp Track Hoppers For Paddle Feeder Travel. , Ring Granulator Crushers For Coal Complete With Scoop Couplings ( Air Cooled Type ) , Hydraulic Door Opening Mechanism, Vibration Isolation System, Drive Base Frames And Associated Electrical ( Except Ht Motor ) And Control & Instrumentation Equipment Along With Startup And Commissioning Spares. 1750Tph Rated / 1925Tph Design / 1925Tph Guaranteed Capacity. , Vibrating Feeders Before Crusher With Solid Deck With All Electricals And C&I. 1750Tph Rated / 1925Tph Design / 1925Tph Guaranteed Capacity. , Minimum Equipment To Be Considered For Chp Building And Workshop , 3 Phase Welding Machine , Bench Grinder , Bench Drilling M / C ( 20Mm ) , Bench Vice ( Size 100Mm -200Mm ) , Monorail Hoist 5 Mt , Induction Bearing Heater , Portable T&Ps Like Grinder, Drill Machine, Welding Machine, Mechanical And Hydraulic Jacks / Pullers, Cutting Set, Chain Pulley Blocks, Max Pullers, Electronic Weighing M / C , 10T Eot Crane Along With All Electricals And C&I For Chp Workshop Building With Rails And Rail Fixing Accessories For Eot Cranes. , Minimum Equipment To Be Considered For Dozer Shed , Air Compressor , Gas Cutting , Gas Welding , Brazing Set , 3 Phase Welding Machine , Bench Grinder , Bench Drilling M / C ( 20Mm ) - , Bench Vice ( Size 100Mm -200Mm ) , Minimum Tools And Tackles To Be Considered , Torque Wrench Required Up To M24 Bolts , Bearing Puller Set To Pull Up To Maximum Bearing Size In System , Hydraulic Jack 50 T , Lifting Trolley For Lt Circuit Breakers , Electrical Power Winch With Wire Rope 7.5 T & 1500 M Galvanized Wire Rope , Bearing Grease Gun , Complete Conveyor Tunnel Ventilation For Chp & Lhp And Ventilation Of Underground Transfer Points, Underground Portion Of Coal Track Hoppers, Underground Portion Of Wagon Tippler Complex, Underground Portion Of Limestone Reclaim Hopper Etc. For Chp & Lhp As Per Specification Complete With All Mechanical & Electrical Accessories. , Complete Dry Type Pressurized Ventilation System For Following Mcc Rooms / Switchgear Rooms As Per Specification Complete With All Mechanical & Electrical Accessories. - Chp Mcc-1 - Chp Mcc-2 - Chp Mcc-3 - Chp Mcc-4 - Chp Mcc-5 , Complete Ventilation System For Bunker Bay ( Housing Tripper Conveyors For Chp, Lhp, Ghp And Ash Conveyor System Ba Main Silos Top Floor ) , , Chp Workshop Building, Battery Room Of Control Rooms, Toilets, Roof Extractors For Lhp Over Ground Storage Shed, Roof Extractors For Ghp Over Ground Storage Shed Etc. Complete With All Mechanical & Electrical Accessories. , Complete Air Conditioning System For Following Buildings, As Per Specification Complete With All Mechanical & Electrical Accessories. - Chp Mcc-1 ( Near Track Hopper ) Rio Room - Chp Mcc-2 ( Near Tp 2A ) Rio Room - Chp Mcc-3 ( Near Crh ) Control Room - Chp Mcc-3 ( Near Crh ) Rio Room - Chp Main Office Room ( In Chp Mcc-3 ) - Chp Mcc-4 ( Near Tp 4 ) Rio Room - Chp Mcc-5 ( Near Tp 5 ) Rio Room - Wagon Tippler Control Room 1 - Wagon Tippler Control Room 2 - Split Acs For Office Rooms , Electrical & C&I For All Chp Equipment Above, As Per Electrical Scope ( Section D Of This Spec. ) Shall Be Considered Under This Head: Ht Motors, Lt Motors, Trailing / Flexible Cables, All Data Cables / Special Cables, Temperature Transmitters, Power & Control Junction Boxes, All Electrical Panels, All Field Devices, Limit Switches, Speed Control Devices, All Brakes And Clamps With Complete Accessories, Earthing & Lightning, , Dcs Logic & Hmi Development Documents, Chp Control Desk, Main Mcc, Lt Bus Ducts, Lt Transformers, Vibration Monitoring System For Crushers, Illumination, Cable Trays & Supports, Hooters, Power Distribution Boards, Plc, Ups, Cable Terminations, Brackets And Structural Steel, Maintenance Tools & Tackles, Ac, Ropes, Conduits Etc., As Per Electrical Scope Matrix. , Mechanical Mandatory Spares For Chp ( As Per Annexure-7 Total For Mechanical Mandatory Spares For Chp Conveyor System ------ ( A ) ) , Electrical C& I Mandatory Spares For Chp ( As Per Annexure-7 Total For Electrical C&I Mandatory Spares For Chp Conveyor System ------ ( B ) ) , Electrical C& I Mandatory Spares Common For All ( As Per Annexure-7 Total For Common Electrical C&I Mandatory Spares For All System ----- ( C ) ) , Limestone Handling Plant , Conveyor System ( 1200 Mtph Rated / 1320 Mtph Design, 1200Mm Belt Width, 2 M / S Approx. Speed And & Only For Ls Conv. 5A / B 200 Mtph Rated / 220 Mtph Design, 1200Mm Belt Width, 2 M / S Approx. Speed ) Complete With Idlers ( With Frames, Brackets ) , All Types Of Pulleys With Plummer Blocks And Bearings, Deflector Rollers, Drive Chain System ( Motors, Gear Boxes, All Types Of Fluid Couplings ( Fluid Coupling, Scoop Coupling, Flexible Coupling, Geared Couplings, Other Input And Output Couplings ) , Brakes, Technological Structures, Including Gtu Towers ( Other Than With Tps And Conveyor Trestles ) , Gtu Travel Guide Pipes, Ci Counter Weights ( If Applicable ) , Cradles, Short Supports, Stringers, Stools, Skirt Board And Skirt Rubber, Deck Plates Throughout Conveyor Length , Maintenance Platforms, Inspection Doors, Inspection Stools, Ladders, Bolts, Anchor Fasteners, Templates, External Scrappers, Internal Scrappers, Foundation Bolts & Nuts, Rubber Sealing, Drive Base Frame, Base Plate, Shim Plate Etc. With All Electricals And C&I ( Except For Items Indicated Separately Under Electrical , C&I As Per Electrical Scope ( Section D Of This Spec. ) . , Conveyor System ( 150 Mtph Rated / 165 Mtph Design, 650Mm Belt Width, 1 M / S Approx. Speed ) Complete With Idlers ( With Frames, Brackets ) , All Types Of Pulleys With Plummer Blocks And Bearings, Deflector Rollers, Drive Chain System ( Gear Boxes, All Types Of Fluid Couplings ( Fluid Coupling, Scoop Coupling, Flexible Coupling, Geared Couplings, Other Input And Output Couplings ) , Brakes, Technological Structures, Including Gtu Towers ( Other Than With Tps And Conveyor Trestles ) , Gtu Travel Guide Pipes, Ci Counter Weights, Cradles, Short Supports, Stringers, Stools, Skirt Board And Skirt Rubber, Deck Plates Throughout Conveyor Length , Maintenance Platforms, Inspection Doors, Inspection Stools, Ladders, Bolts, Anchor Fasteners, Templates, External Scrappers, Internal Scrappers, Foundation Bolts & Nuts, Rubber Sealing, Chutes, Drive Base Frame, Base Plate, Shim Plate Etc. With All Electricals And C&I ( Except For Items Indicated Separately Under Electrical , C&I As Per Electrical Scope ( Section D Of This Spec. ) . , Complete Set Of Plough Diverter Feeding The Limestone From 650Mm Belt To Limestone Day Silos Of Capacity 150Tph / 165Tph Along With All Accessories, Chute Work, Plough Actuators And Enclosures For Duct Control. , Inline Magnetic Separators With Belt, Drives, Fixing Lugs, Slings, Fixing Accessories, Tramp Iron Chute Up To Ground Level, Reject Trolley And With All Electricals And C&I Etc. , Metal Detectors Along With All Electricals And C&I For 1200Mm Belt Width , Metal Detectors Along With All Electricals And C&I For 650Mm Belt Width , Suspended Magnet Along With Fixing Lugs, Slings, Fixing Accessories, Tramp Iron Chute, Reject Trolley, All Electricals And C&I. , Belt Weighers Along With All Electricals And C&I. , Chutes With Chute Support Structure, Chute Block Switches In Tps, Crusher House, Reclaim Hopper Complex, Etc. Including Liners In Crusher Supporting Rcc Deck, Tramp Iron Chutes Upto Ground Level And With All Electricals And C&I. , Complete Travelling Tripper With Telescopic Chute & Dust Collector Arrangement, Drives, Flap Gates ( Motorized ) With Actuator, Two- Way Chute, Including Supports, For Each Limestone Travelling Tippler, Including Rails, Rail Fixtures, Clamps And Other All Electricals And C&I, Drives & Accessories. Rated / Design Capacity: - 1200 / 1320 Tph. ( For Drives Geared Motors Are Not Acceptable, So Bidder To Provide Conventional Electro Mechanical Drive I.E. Gearbox, Brake And Motor ) . Drive Rating Shall Be Min. 2 X 50 %. , Complete Limestone Sampling Unit With All Electricals And C&I , 200Tph / 220Tph Bulk Material Receiving Unit Or Box Feeder Or Surface Feeder With Dust Enclosures With All Electricals And C&I , Truck Tippler 60T Gross Capacity With All Electricals And C&I , Flap Gates With Motorized Actuator Including Limit Switches, Fixing Supports, Maintenance Access And All Electricals And C&I. , Rack And Pinion Gates With Actuators, Fixing Supports, Maintenance Access And All Electricals And C&I. , Rod Gates, Fixing Supports, Maintenance Access. , 1000Kg Rope & Sheave Type Passenger Cum Goods Elevator Shall Be Provided Along With Electricals And C&I For Limestone Crusher House. The Elevator Shall Be Designed As Per Clause No 5.17.0 And Data Sheet Of Elevator Of Sub Section-A-23, Of Part B Of Technical Specifications. , Belt Vulcanizing Machine With Tool Kit For 1400 Mm Belt Width With All Accessories, Consumables, Etc With All Electricals And C&I. , Rails & Rail Fixtures For Limestone Paddle Feeder Machine ( 150Tph ) In Lhp Reclaim Hoppers For Paddle Feeder Travel. , Complete Individual Dry Type Dust Extraction System For Following Lhp Buildings Comprising Of Dust Collection Hoods, Ducting & Duct Support, Centrifugal Fans, Stack, Stack Support, Bag Filter System With Sequential Controller, Rotary Air Lock, Bag Filter Support Structure, And Dust Collection Hopper, Including All Structures, Duct Supports, Supporting Structures, Bellows, Piping, Fittings, Gauges, Switches, Other Instrumentations, Valves, Drive Base Frames, Dampers ( Manual & Electrical ) Etc. With All Associated Electricals And C&I. The Extraction Capacity Of Dust Extraction System Shall Be Based On American Conference Of Governmental Industrial Hygienists ( Acgih ) . , De System For Limestone In Ls Jt-1 , De System For Lime Stone In Crusher House Of Limestone , Common De System For Lime Stone In Ls Jt-2 & Bulk Material Receiving / Box Feeder / Surface Feeder Unit , De System For Limestone In Ls Jt-3 , Common Compressed Air System For Lhp Building & Limestone Storage Area De System Comprising Of 2 Sets Of Screw Compressors ( 1W+1S ) To Be Located In Ph-A Complete Compressed Air Piping Network With Valves, Fittings And Air Receivers For Dry De System Along With All Associated Electricals And C&I. , Reversible Hammer Mill Crusher For Limestone, Direct Drive ( No Gear Box Or Belt Pulley Drive Is Acceptable ) With Air Cooled Scoop Coupling, Vibration Isolation System, Hydraulic Door Opening Mechanism Drive Base Frames And Associated Electrical ( Except Ht Motor ) And Control & Instrumentation Equipment Along With Startup And Commissioning Spares. 1200Tph Rated / 1320Tph Design / 1200Tph Guaranteed Capacity. , Vibrating Feeders Before Crusher With Solid Deck With All Electricals And C&I. 1200Tph Rated / 1320Tph Design / 1200Tph Guaranteed Capacity. , Nylon-Nylon Belt For Conveyors ( As Applicable ) , With Splicing Kit As Per Requirement And Specification. , Complete Set Of Plough Diverter For Tapping & Diverting The Limestone Flow From 2000Mm Belt Towards Limestone Crusher House Of Capacity 1200Tph / 1320Tph Along With All Accessories, Chute Work, Plough Actuators And Enclosures For Duct Control. , Electrical & C&I Of All Above Lhp Equipment’S As Per Electrical Scope ( Section D Of This Spec. ) Shall Be Considered Under This Head: Ht Motors, Lt Motors, Trailing / Flexible Cables, All Data Cables / Special Cables, Temperature Transmitters, Power & Control Junction Boxes, All Electrical Panels, All Field Devices, Limit Switches, Speed Control Devices, All Brakes And Clamps With Complete Accessories, Earthing & Lightning, Dcs Logic & Hmi Development Documents, Chp Control Desk, Main Mcc, Lt Bus Ducts, Lt Transformers, Vibration Monitoring System For Crushers, Illumination, Cable Trays & Supports, Hooters, Power Distribution Boards, Plc, Ups, Cable Terminations, Brackets And Structural Steel, Maintenance Tools & Tackles, Ac, Ropes, Conduits Etc., As Per Electrical Scope Matrix. , Mechanical Mandatory Spares For Lhp As Per Annexure-7 Total For Mechanical Mandatory Spares For Lhp Conveyor System------- ( D ) , Electrical C& I Mandatory Spares For Lhp As Per Annexure-7 Total For Electrical C&I Mandatory Spares For Lhp Conveyor System ------ ( E ) , Gypsum Handling Plant , Conveyor System ( 150 Mtph Rated / 165 Mtph Design, 650Mm Belt Width, 1 M / S Approx. Speed ) Complete With Idlers ( With Frames, Brackets ) , All Types Of Pulleys With Plummer Blocks And Bearings, Deflector Rollers, Drive Chain System ( Gear Boxes, All Types Of Fluid Couplings ( Fluid Coupling, Scoop Coupling, Flexible Coupling, Geared Couplings, Other Input And Output Couplings ) , Brakes, Technological Structures, Including Gtu Towers ( Other Than With Tps And Conveyor Trestles ) , Gtu Travel Guide Pipes, Ci Counter Weights ( If Applicable ) , Cradles, Short Supports, Stringers, Stools, Skirt Board And Skirt Rubber, Deck Plates Throughout Conveyor Length , Maintenance Platforms, Inspection Doors, Inspection Stools, Ladders, Bolts, Anchor Fasteners, Templates, External Scrappers, Internal Scrappers, Foundation Bolts & Nuts, Rubber Sealing, Drive Base Frame, Base Plate, Shim Plate Etc. With All Electricals And C&I ( Except For Items Indicated Separately Under Electrical , C&I As Per Electrical Scope ( Section D Of This Spec. ) , Chutes With Chute Support Structure, Chute Block Switches In Tps With All Electricals And C&I. , Flap Gates With Actuators With Supports, All Electricals And C&I. , Nylon-Nylon Belt For Conveyors ( As Applicable ) , With Splicing Kit As Per Requirement And Specification. , Complete Travelling Tripper With Drives, Flap Gates ( Motorized ) With Actuator, Two-Way Chute, Incl. Supports, Rails, Rail Fixtures, Clamps And Other All Electricals And C&I, Drives & Accessories. Rated / Design Capacity: - 150 / 165 Mtph. ( For Drives Geared Motors Are Not Acceptable, So Bidder To Provide Conventional Electro Mechanical Drive I.E. Gearbox, Brake And Motor ) . Drive Rating Shall Be Min. 2 X 50 %. , Belt Sealing Arrangement ( Including Supply Of Belt ) . , Electrical & C&I For All Above Ghp Equipment’S As Per Electrical Scope ( Section D Of This Spec. ) Shall Be Considered Under This Head: Ht Motors, Lt Motors, Trailing / Flexible Cables, All Data Cables / Special Cables, Temperature Transmitters, Power & Control Junction Boxes, All Electrical Panels, All Field Devices, Limit Switches, Speed Control Devices, All Brakes And Clamps With Complete Accessories, Earthing & Lightning, Dcs Logic & Hmi Development Documents, Chp Control Desk, Main Mcc, Lt Bus Ducts, Lt Transformers, Vibration Monitoring System For Crushers, Illumination, Cable Trays & Supports, Hooters, Power Distribution Boards, Plc, Ups, Cable Terminations, Brackets And Structural Steel, Maintenance Tools & Tackles, Ac, Ropes, Conduits Etc., As Per Electrical Scope Matrix. , Ash Handling Plant - Conveyor System , Conveyor System ( 267 Mtph Rated / 294 Mtph Design, 800Mm Belt Width, 2.2 M / S Approx. Speed ) Complete With Idlers ( With Frames, Brackets ) , All Types Of Pulleys With Plummer Blocks And Bearings, Deflector Rollers, Drive Chain System ( Gear Boxes, All Types Of Fluid Couplings ( Fluid Coupling, Scoop Coupling, Flexible Coupling, Geared Couplings, Other Input And Output Couplings ) , Brakes, Technological Structures, Including Gtu Towers ( Other Than With Tps And Conveyor Trestles ) , Gtu Travel Guide Pipes, Ci Counter Weights ( If Applicable ) , Cradles, Short Supports, Stringers, Stools, Skirt Board And Skirt Rubber, Deck Plates Throughout Conveyor Length , Maintenance Platforms, Inspection Doors, Inspection Stools, Ladders, Bolts, Anchor Fasteners, Templates, External Scrappers, Internal Scrappers, Foundation Bolts & Nuts, Rubber Sealing, Drive Base Frame, Base Plate, Shim Plate Etc. With All Electricals And C&I ( Except For Items Indicated Separately Under Electrical , C&I As Per Electrical Scope ( Section D Of This Spec. ) , Conveyor System ( 800 Mtph Rated / 880 Mtph Design, 1200Mm Belt Width, 2.8 M / S Approx. Speed ) Complete With Idlers ( With Frames, Brackets ) , All Types Of Pulleys With Plummer Blocks And Bearings, Deflector Rollers, Drive Chain System ( Gear Boxes, All Types Of Fluid Couplings ( Fluid Coupling, Scoop Coupling, Flexible Coupling, Geared Couplings, Other Input And Output Couplings ) , Brakes, Technological Structures, Including Gtu Towers ( Other Than With Tps And Conveyor Trestles ) , Gtu Travel Guide Pipes , Ci Counter Weights ( If Applicable ) , Cradles, Short Supports, Stringers, Stools, Skirt Board And Skirt Rubber, Deck Plates Throughout Conveyor Length , Maintenance Platforms, Inspection Doors, Inspection Stools, Ladders, Bolts, Anchor Fasteners, Templates, External Scrappers, Internal Scrappers, Foundation Bolts & Nuts, Rubber Sealing, Drive Base Frame, Base Plate, Shim Plate Etc. With All Electricals And C&I ( Except For Items Indicated Separately Under Electrical , C&I As Per Electrical Scope ( Section D Of This Spec. ) .Bidder To Note That For Conveyor Ba Bcn # 5A / B Ht Drive Shall Be Considered Irrespective Of Drive Rating Arrived After Calculation. Ht Motor Shall Be Provided By Bhel As Per Electrical & C&I Scope Matrix And As Mentioned Elsewhere But Bidder To Accordingly Consider Scoop Type Fluid Coupling And Gear Box For Ba Bcn # 5A / B. , Conveyor System ( 2600 Mtph Rated / 2860 Mtph Design, 1800Mm Belt Width, 3.25 M / S Approx. Speed ) Complete With Idlers ( With Frames, Brackets ) , All Types Of Pulleys With Plummer Blocks And Bearings, Deflector Rollers, Drive Chain System ( Gear Boxes, All Types Of Fluid Couplings ( Fluid Coupling, Scoop Coupling, Flexible Coupling, Geared Couplings, Other Input And Output Couplings ) , Brakes, Technological Structures, Including Gtu Towers ( Other Than With Tps And Conveyor Trestles ) , Gtu Travel Guide Pipes, Ci Counter Weights ( If Applicable ) , Cradles, Short Supports, Stringers, Stools, Skirt Board And Skirt Rubber, Deck Plates Throughout Conveyor Length , Maintenance Platforms, Inspection Doors, Inspection Stools, Ladders, Bolts, Anchor Fasteners, Templates, External Scrappers, Internal Scrappers, Foundation Bolts & Nuts, Rubber Sealing, Drive Base Frame, Base Plate, Shim Plate Etc. With All Electricals And C&I ( Except For Items Indicated Separately Under Electrical , C&I As Per Electrical Scope ( Section D Of This Spec. ) , Complete Belt Feeders Under Main Fly Ash Silo 1 To 6 ( 1200 Bw At 1.0 M / S Approx. Speed ) Rated 325Tph / Design 358Tph ( Including Supply Of Belt ) With All Electricals And C&I. , Complete Belt Feeders Under Main Bottom Ash Silo 1 To 3 ( 1400 Bw At 1.6 M / S Approx. Speed ) Rated 650Tph / Design 715Tph ( Including Supply Of Belt ) With All Electricals And C&I. , Complete Belt Feeders In Ba Tp-6 ( 1400 Bw At 2 M / S Approx. Speed ) Rated 800Tph / Design 880Tph ( Including Supply Of Belt ) With All Electricals And C&I. , Belt Weighers ( On Conveyor With 267 Mtph Rated / 294 Mtph Design, 800Mm Belt Width, 2.2 M / S Approx. Speed ) Along With All Electricals And C&I. , Belt Weighers ( On Conveyor With 800 Mtph Rated / 880 Mtph Design, 1200Mm Belt Width, 2.8 M / S Approx. Speed ) Along With All Electricals And C&I. , Belt Weighers ( On Conveyor With 2600 Mtph Rated / 2860 Mtph Design, 1800Mm Belt Width, 3.25 M / S Approx. Speed Along With All Electricals And C&I. , Chutes With Chute Support Structure, Chute Block Switches In Tps, Silo Buildings Etc With All Electricals And C&I. , Complete Set Of Plough Diverter For Feeding Bottom Ash Flow To Bottom Ash Main Silos From 1200Mm Belt Towards Of Capacity 800Tph / 880Tph Along With All Accessories, Chute Work, Plough Actuators And Enclosures For Duct Control. , Flap Gates ( Two Way & Three Way ) With Actuators With Supports, All Electricals And C&I. , Electrical Hoist With All Electricals And C&I. ( All Ash Conveyor Buildings Including Bottom Ash & Fly Ash Main Silo Floors ) , Manual Hoist With Travelling Trolley And Chain Pulley Blocks. , Sump Pumps Including Discharge Piping Valves, Accessories & Support Structure Along With All Electrics And C&I With All Electricals And C&I For Ash Conveyor System. , Nylon-Nylon Belt For Conveyors ( As Applicable ) , With Splicing Kit As Per Requirement And Specification , Electrical & C&I I Of All Above Ahp Conveyor System As Per Electrical Scope ( Section D Of This Spec. ) Shall Be Considered Under This Head: Ht Motors, Lt Motors, Trailing / Flexible Cables, All Data Cables / Special Cables, Temperature Transmitters, Power & Control Junction Boxes, All Electrical Panels, All Field Devices, Limit Switches, Speed Control Devices, All Brakes And Clamps With Complete Accessories, Earthing & Lightning, Dcs Logic & Hmi Development Documents, Chp Control Desk, Main Mcc, Lt Bus Ducts, Lt Transformers, Vibration Monitoring System For Crushers, Illumination, Cable Trays & Supports, Hooters, Power Distribution Boards, Plc, Ups, Cable Terminations, Brackets And Structural Steel, Maintenance Tools & Tackles, Ac, Ropes, Conduits Etc., As Per Electrical Scope Matrix. , Mechanical Mandatory Spares For Ash Conveyors ( As Per Annexure-7 Total For Mechanical Mandatory Spares For Ash Conveyor System ------ ( F ) ) , Electrical C& I Mandatory Spares For Ash Conveyors ( As Per Annexure-7 Total For Electrical C&I Mandatory Spares For Ash Conveyor System ------ ( G ) ) , Type Test Charges, As Per Contract Specifications , Installation Services, Erection & Commissioning, Pg Test , Installation Services For Entire Chp, Lhp, Ash Conveyor System & Ghp Including All Equipment / Systems As Per Scope Defined In Nit Specification Comprising Of Receipt, Unloading, Handling, Transportation & Storage At Site, Construction Of Stores At Site ( Open & Closed ) , Lifting / Shifting To Closed / Open Storage, In-Site Transportation, To Make Approach Road Wherever Required, Round The Clock Security At Open Storage Yard , Closed Storage Shed & Erected Material Till Completion Of Work, Assembly, Complete Erection, Alignment, Carrying Out Pre-Commissioning, Commissioning, Trial Run At Site And Carrying Out Performance Guarantee Tests, Reliability Test Run, Functional / Demonstration Tests At Site ( As Applicable Obtaining Provisional Acceptance Certificate ( Pac ) , Final Acceptance Certificate ( Fac ) And Handing Over Of The Equipment & Systems Under Chp, Lhp, Ash Conveyor System & Ghp Complete With All Accessories For The Total Scope Defined As Per Bhel Nit & Tender Technical Specification, Amendment & Agreements Till Placement Of Order. ( Except For Items Indicated Separately Under Electrical, C&I As Per Electrical Scope ( Section D Of This Spec ) , Receipt At Site, Unloading And Storage Of All Bhel Free Issue Items Like Ht Motor Etc. And Its Erection, Testing & Commissioning. , Construction Of Open Storage Yard And Closed Storage Shed: A. Closed Storage Shed :Construction Of Temporary Closed Covered Storage Shed For Storage & Preservation Of All Supplied Material For This Package ( Including Free Issue Items ) With Minimum Dimension - Length 40M X Width 20M X Height 8M ) With : 1. Brick Wall Construction, Concrete Flooring, Sloped Roof, Rolling Shutter, Rcc Column With Max. Span Of 6 Meters, Rcc Beams At Every 3M Height From Finished Floor Level, Brick Infill Up To Total Height Of Shed Or 2.With Bolted Rcc Column Foundation, Plinth Beams, Concrete Flooring, Steel Structure With Roof Truss And Covered With Color Coated Sheets In All Sides, Rolling Shutters. Windows And Access Doors Shall Be Provided And It Shall Be In The Scope Of Bidder. B. Open Storage Yard: Levelled And Graded Area Will Be Allotted For Construction Of Open Storage Yard Outside Plant Premises At Annex Storage Yard. Bidder Shall Make Ready Open Storage Yard Suitably To Obtain Storage Clearance From Customer. Bidder Shall Also Consider Fencing / Illumination Of Open Storage And Site Fabrication Area As And When Allocated At Site. , Touch- Up Painting At Site After Erection. , Operation & Maintenance ( As Defined In The Enquiry Specification ) , Training Module For Chp, Lhp, Ghp & Ash Conveyor System Comprising Following Aspect: - Product Design , - Basic Design Features - Theory & Principle Of Operation - Latest Technological Trends In Coal Handling Plant And Design Plant Visit - Testing Facilities - Operational Feedback - O&M History / Problems Related To Coal Handling Plant Visit To Manufacturer’S Work - Manufacturing Process Of Coal Handling Equipment Operation & Maintenance Of Plant - Trouble Shooting And Fault Analysis - Familiarization Of Special Maintenance Techniques - Special Tool And Tackles Familiarization , The Contractor Shall Provide Three ( 3 ) Years Of Comprehensive Annual Maintenance Contract Which Will Start After Defect Liability Period ( Defect Liability Period Is Defined In Contract Specifications ) As A Part Of Offer / Bid By The Bidder. This Shall Include Calibration Of Analyzers, Supply / Replacement Of Any Required Sensor / Material ( Including Nucleonic Source, If Applicable For Analyzer Technology, Which Requires Top Up / Replacement Up To Three Year Amc Period ) , Rectification Of Faults Reported ( Within 48 Hours ) , To Keep Analyzer Fully Functional, During Defect Liability Period / Amc Period. In Case Of Nucleonic Type Analyzers, All Regulations Required By Indian Law Including That By Aerb / Other Agencies Will Be Complied By Contractor. All Necessary Arrangements To Get Regulatory Clearances Will Be Responsibility Of Contractor. Ntpc Site Will Provide Necessary Documentation / Noc To Facilitate This Process. Any Other Requirement Related To Aerb Clearances Will Be Discussed & Tied Up Before Award Of Contract. The Contractor Shall Follow All Guidelines Of Aerb / Other Regulatory Agencies For Proper Installation / Operation Of Nucleonic Type Coal Analyzers. , Services Of All Items Indicated Separately Under Electrical , C&I As Per Electrical Scope Matrix Annexure-2 And ( Section D Of This Spec. ) For Chp, Lhp, Ash Conveyor System , Ghp System Including Bhel Free Supplied Items Starting From Its Receipt At Site, Unloading, Lifting / Shifting To Closed / Open Storage , Storage, Shifting To Erection Location, To Make Approach Road Wherever Required, Round The Clock Security Of Closed & Open Storage And Erected Material, Erection, Alignment, Carrying Out Pre-Commissioning, Commissioning, Performance Guarantee Tests, Reliability Test Run, Obtaining Provisional Acceptance Certificate ( Pac ) , Final Acceptance Certificate ( Fac ) And Handing Over Of The Equipment & System Which Is Under The Scope Of Supply And Service Of The Bidder And Bhel Free Supplied Items. Complete E&C For All Electrics, C&I Including Bhel Free Issue Items, Support For Dcs Logic & Hmi Fine Tuning In Line With Control Write Up As Per Annexure-2. , Cif Content Included In The Quoted Price. ( Bidder To Note That This Price Is For Information Only And The Same Will Not Be Added For Arriving At The Grand Total Price For Evaluation. )

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail