Military Engineer Services-MES has published Maintenance Repair To Summer Appliances And Other Connected Items Under Age Em I Of Ge North Meerut Cantt. Submission Date for this Tender is 03-06-2022. Air Conditioner Tenders in meerut Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 17-May-2022 | BOQ Amendment | BOQ | 27-05-2022 |
2 | 27-May-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-06-2022 |
Sl. No. | Item Description |
1 | M&L for servicing, repair and replacement ofunserviceable parts at E/M yard including opening offan body, cleaning, separating serviceable parts for reuse / refixsame after repairing andreplacing defecive parts witth new one (new spares followed below shall be measured and paid seperately, minor spares and consumables like screws, washers, grease, cleaning agents, consumables etc. is deemed to be included in the cost ) reassembling, greasing completeall as specified and directed for the following:- (a) Ceiling Fan 1200mm Sweep of any make or model |
2 | All as per Srl item No 01 here-in-before but Ceiling Fan 1400mm Sweep of any make or model |
3 | All as per Srl item No 01 here-in-before butWall / Cabin Fan 400 / 450mm Sweep of any make or model |
4 | All as per Srl item No 01 here-in-before but Exhaust Fan 250/ 300mm Sweep of any make or model |
5 | All as per Srl item No 01 here-in-before but Exhaust Fan 380mm Sweep of any make or model |
6 | All as per Srl item No 01 here-in-before but Exhaust Fan 450mm Sweep of any make or model |
7 | All as per Srl item No 01 here-in-before but Pedestal Fan 400 / 450mm Sweep of any make or model |
8 | All as per Srl item No 01 here-in-before but Air Circulator Fan 600mm Sweep of any make or model |
9 | M & L for rewinding the fans of any make, any model, from a reputed workshop, removing the burnt winding, cleaning slots, re-winding the motor with super enameled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc, replacement of body screws, testing and commissioning on full load for 4 hrs continuous running all as directed for the following:- (a) Ceiling Fan 1200mm Sweep of any make or model |
10 | All as per Srl item No 09 here-in-before but Ceiling Fan 1400mm Sweep of any make or model |
11 | All as per Srl item No 09 here-in-before but Wall / Cabin Fan 400 / 450mm Sweep of any make or model |
12 | All as per Srl item No 09 here-in-before bu tExhaust Fan 300mm Sweep of any make or model |
13 | All as per Srl item No 09 here-in-before but Exhaust Fan 380mm Sweep of any make or model |
14 | All as per Srl item No 09 here-in-before but Exhaust Fan 450mm Sweep of any make or model |
15 | All as per Srl item No 09 here-in-before but Pedestal Fan 400 / 450mm Sweep of any make or model |
16 | All as per Srl item No 09 here-in-before but Air Circulator Fan 600mm Sweep of any make or model |
17 | M & L for Preparing the surface, removethe existing painting by scraping, cleaning, filling the cavities and applying 2 coats of spray paint of synthetic enamel white / Brown paint over a coat of red oxide primer, including writing the MES Nos. all as directed for the following:- (a) Ceiling Fan 1200mm Sweep of any make or model |
18 | All as per Srl item No 17 here-in-before but Ceiling Fan 1400mm Sweep of any make or model |
19 | All as per Srl item No 17 here-in-before but Wall / Cabin Fan 400 / 450mm Sweep of any make or model |
20 | All as per Srl item No 17 here-in-before but Exhaust Fan 300mm Sweep of any make or model |
21 | All as per Srl item No 17 here-in-before but Exhaust Fan 380mm Sweep of any make or model |
22 | All as per Srl item No 17 here-in-before but Exhaust Fan 450mm Sweep of any make or model |
23 | All as per Srl item No 17 here-in-before but Pedestal Fan 400 / 450mm Sweep of any make or model |
24 | All as per Srl item No 17 here-in-before but Air Circulator Fan 600mm Sweep of any make or model |
25 | S&F, Condensor / Capacitor, 240V, AC, suitable for fans all as directed for the following:- a)2.5 mfd |
26 | All as per Srl item No 25 here-in-before but3.15 mfd |
27 | All as per Srl item No 25 here-in-before but4.0 mfd |
28 | S&F, Ball bearing made out of high carbon steel, equivalent to the original, 6201/6202/6203/6204/NF-8/6205, suitable for any type, any make, any size fans completeall as specified and directed. Make: SKF / NBC / FAG . |
29 | S&F, GM Bush bearing, equivalent to the original, X-I, X-2, X-3, X-4, suitable for any type, any make, any size, fan completeall as specified and directed |
30 | S&F, Nickel plated mild steel clamps,rubber reel insulator Nuts, Bolts, Washers and split pin suitable for ceiling fansany type, any make, any size completeall as specified and directed |
31 | S&F, Down rod, suitably threaded and holed, made out of 15mmdia GI tubes, duly painted, 300mm long, suitable for ceiling fansany type, any make, any size completeall as specified and directed |
32 | All as per Srl item No 31 here-in-before but600mm long |
33 | All as per Srl item No 31 here-in-before but900mm long |
34 | S&F, Fan canopy with tightening screw/check nut, made out of PVC, suitable for ceiling fansany type, any make, any size completeall as specified and directed |
35 | S&F, Rubber reel insulator, suitable for ceiling fansany type, any make, any size completeall as specified and directed |
36 | S&F, Bakelite body Nichrome connectors, 2 way with fixing screws of suitable size for ceiling fans of any type, any make completeall as specified and directed |
37 | PVC condenser holder /rubber condenser holderwith PVC connector for ceiling/ Exhaust fanscompleteall as specified and directed |
38 | MS nut bolt 50 mm long 8 mm dia for ceiling fanscompleteall as specified and directed |
39 | All as per Srl item No 38 here-in-before but 100 mm long - Ditto - |
40 | MS screw for fixing ceiling fan bladescompleteall as specified and directed |
41 | Clutchfor ceiling fan made out of GI heavy both end threaded as per sample suitable for 1200 /1400 mm sweep ceiling fancompleteall as specified and directed |
42 | Metal bottom cover of ceiling fan complete with bearing holder suitable for any type,any make or model completeall as specified and directed |
43 | All as per Srl item No 42 here-in-before buttop cover of ceiling fans. |
44 | Magnetic ring of ceiling fans for any type,any make or model completeall as specified and directed |
45 | S&F, Fan blades made out of 1.2mm thick Aluminium alloy and MS screws duly balanced & spray painted with White or Brown colour, Set of three, suitable for ceiling fans of any type, any make all as directed for the following:- (a) 1200mm Sweep |
46 | All as per Srl item No 45 here-in-before but 1400mm Sweep |
47 | S&F, Fan blades made out of Acrylic / PVC alloy and MS screws duly balance suitable for 450mm wall / cabin fans of any type, any make, completeall as specified and directed |
48 | S&F, Fan blades made out of thick Aluminium alloy and MS screws duly balanced & spray painted with approved colour, suitable for Exhaust fans of any type, any make all as directed for the following:- (a) 300mm Sweep |
49 | All as per Srl item No 48 here-in-before but380mm Sweep |
50 | All as per Srl item No 48 here-in-before but450mm Sweep |
51 | S&F, Fan blades made out of Acrylic / PVC alloy and MS screws duly balance suitable for 400 / 450mm Pedestal fan of any type, any make, all as directed. |
52 | S&F, Fan blades made out of thick Aluminium alloy and MS screws duly balanced & spray painted with approved colour, suitable for 600mm Air Circulator fan of any type, any make completeall as specified and directed |
53 | S&F, 1100V grade PVC sheathed PVCinsulated flexible 3 core cable with multistranded copper conductor of size 1.5Sqmm, ISI Marked completeall as specified and directed |
54 | Supply & fixing in repair base plate for wall mounting fan any type/ size as per existing size of fan completeall as specified and directed |
55 | Supply & fixing in repair regulator for wall mounting fan any type/ size as per existing size of fan completeall as specified and directed |
56 | Supply & fixing in repair protection cover (jali) complete front and backfor wall mounting fan any type/ size as per existing size of fan completeall as specified and directed |
57 | M&L for making hole in wall, Grouting 4Nos Rag Bolts of size 125mm long x 12mmm dia in PCC on wall including suitable nuts and washers for fixing / hanging geysers, completeall as specified and directed |
58 | S&F PVC sheathed,PVC insulated multi stranded copper conductor, 3 core, flexible cable, 1100 V grade, 2.5Sqmm, AC, connecting completeall as specified and directed |
59 | S&F in repair for plug top 3 pin 15 Amps capacity complete all as specified and directed . |
60 | Supply onlyZebra fastner of size 12x100 mm complete all asspecified and directed . |
61 | S&F in repair modular Power Unit 20A, 3pin, AC, 240V ISI Marked incl FRP Box and 01 No"s 16 Amps MCB SP completeall as specified and directed |
62 | S&F in repair SPN metallic enclosure with a two pin and earth plug and socket with one MCB SP 25 Amps completeall as specified and directed |
63 | S&F in repairs, Wall fan, 450mm sweep, AC,230V incl T/D old u/s one and depositing to MES store complete all as specified and directed. |
64 | S&F in reapirs, PVC fresh air fan, 250mm sweep with louvers, AC, 230V incl T/D old u/s one and depositing to MES complete all as specified and directed. |
65 | AlAll as per Srl item No 64 here-in-before but 200mm sweep |
66 | M&L for making opening in the wall for fixing exhaust fan upto 250mm /200mm, including plastering work & making good the surfaces completeall as specified and directed |
67 | Window Type AC / Split AC :-Disconnection of suction and discharge line connection of sealed unit and taking out the defective sealed unit compressor from window type AC/Split AC of any make any type / any model replacing the defective compressor with any repaired one from any of the authorised workshop//manufacture of Make : Kirloskar/Tecumsch/Carrier refixing the compressor in the original position of window/split type AC making all existing connectionfor 1.5 ton Air conditioner incl OLP / Relay. completeall as specified and directed |
68 | S&F in replacement of new compressor hermetically sealed type equipped with suitable rated capacity electric motor and over load protection making all existing connection complete all as directed for 1.5 ton Window type/split Air conditioners.Make : Kirloskar/Tecumsch completeall as specified and directed |
69 | All as per Srl item No 68 here-in-before but of capacity 2 ton. |
70 | All as per Srl item No 68 here-in-before butInvertor type of capacity 1.5 ton |
71 | M&L for Gas refrigerant R12/R22/R410A/R 134 in the sealed system of window/Split type Air conditioners 1.5/2 Ton capacity after checking leakage / pressure vacumising flushing the sealed unit including replacement of filter drier and capillary tube completeall as specified and directed |
72 | Taking down of window/Split AC 1.5/2.0 any /any modelton capacity and cleaning / serving of AC, overhauling of blower motor replacement of worn out parts, preparation of body for painting one coat of black paint inner side and one coat synthatic enameled paint on the outer cover of AC and making of SM/MES No and testing of full load of summer season and reinstallation at site. Note : Worn out parts shall be measured & paid seperately. completeall as specified and directed |
73 | S&F in repairsplit / window AC of capacity 1.5 / 2 TR (a) Blower motor 1/6 HP with base / rubber bush complete Make AUE / GE Suitable for any make / model completeall as specified and directed |
74 | All as per Srl item No 73 here-in-before butCondensor fan motor 1/5 HP Make : AUE/GE |
75 | All as per Srl item No 73 here-in-before butCondensor fan metallic blade. |
76 | All as per Srl item No 73 here-in-before butDrum type blower fan PVC type. |
77 | All as per Srl item No 73 here-in-before but Running capacitor 36 mfd make EPCOS/Havells/TESLA. |
78 | All as per Srl item No 73 here-in-before butStarting capacitor 100 to 120 mfd make : EPCOS/Havells/TESLA. |
79 | All as per Srl item No 73 here-in-before but Selector switch. Any make / any model |
80 | All as per Srl item No 73 here-in-before butThermostate make : Indfoss / EPCOS |
81 | All as per Srl item No 73 here-in-before but with plastic / juite Air filter. |
82 | All as per Srl item No 73 here-in-before butcooling coil assembly suitable for any make / any model as per site requirement |
83 | All as per Srl item No 73 here-in-before butCondensor coil assembly. |
84 | All as per Srl item No 73 here-in-before butWiring kit. |
85 | All as per Srl item No 73 here-in-before butFront grill plastic type as per sample |
86 | All as per Srl item No 73 here-in-before butCapacitor 6 mfd Make : EPCOS/Havells/TESLA. |
87 | All as per Srl item No 73 here-in-before butBlower motor 1/3 HP for indoor unit split type AC suitable for any Make / any model as per site requirement. |
88 | All as per Srl item No 73 here-in-before butRunning capacitor 45 mfd Make : EPCOS/Havells/TESLA. |
89 | All as per Srl item No 73 here-in-before butBlower fan 3 Ft long suitable for split AC USHA SHRIRAM/LG (as per sample) |
90 | All as per Srl item No 73 here-in-before but Copper wire 3 core 4 sqmm |
91 | Supply and fix in replacement of electronic circuit plate (PCB) including necessary repairs to electronic circuit for remote operation suitable for 1.5 / 2.0 ton split type AC for LG / USHA / SRIRAM. completeall as specified and directed |
92 | Supply and fix in replacement of remote suitable for 1.5 / 2 ton split type AC operation for LG/Usha Sriram completeall as specified and directed |
93 | Supply and fix in replacement Air break contactor relay 6.2 Amps, 415 Volts AC suitable for split type AC. Make:SIEMENS/L&T completeall as specified and directed |
94 | Labour for shifting of split AC 1.5 , 2 ton capacitor one place to another places as required at site and disconnecting of copper tubing, PVC pipe connection and installation of New location indoor/outdoor unit complete with Gas charging tested on full load on summer season. completeall as specified and directed |
95 | M&L for replacement with new indoor unit of capacity 1.5 / 2 ton with cooling coil, blower motor complete with all accessories Make : LG/Voltas / Samsung as per site requirement completeall as specified and directed |
96 | M&L for replacement with new outdoorunit of capacity 1.5 / 2 ton with condensor coil, blower motor 1/6 HP , single phase, including fixing in old serviceable compressor and connection of copper tubing suction / discharge all as specified and directed complete. Make : LG/Voltas / Samsung as per site requirement. completeall as specified and directed |
97 | REFRIGERATOR : Disconnection of unserviceable compressor from suction discharge line and taking out compressor from refrigerator of capacity 300 to 320 ltrs any make and replace the defective compressor with a repaired compressor from anyof the authorised repair workshop / manufacture Make : Godraj / Techmsch with OLP / relay of making all existing connection complete all as directed. completeall as specified and directed |
98 | All as per Srl item No 97 here-in-before but165 to 210 ltrs. |
99 | S&F in replacement of new compressor hermetically sealed type type compressor suitable for 300 to 320 ltrs capacity refrigerator with suitable rated capacity electric motor and shall be equipped with relay / over load protection 230 Volt, 50 Hz, single phase suitable for any make or model. completeall as specified and directed |
100 | All as per Srl item No 99 here-in-before but 300 ltrs |
101 | All as per Srl item No 99 here-in-before but165 ltrs to 260 ltrs. |
102 | M&L for filling/charging Gas refrigerant R22/R134/R438Ain the sealed system of refrigerator of any make /capacity after checking leakage / pressure vacumising flushing the sealed unit including replacement of filter drier and capillary tube completeall as specified and directed |
103 | S&F starting relay with OLP kit suitable for any make Suitable for any / model refrigerator complete with testing and commissioning completeall as specified and directed |
104 | Supply and fix in replacement of thermostat switch suitable for any model / model completeall as specified and directed |
105 | S&F electricLamp 15 watt 230 volt AC thread / pin type suitable for any make / capacity of refrigerator, make : Philips/Bajaj completeall as specified and directed |
106 | M&L for replacement of lamp holder suitable for any make/capacity model of refrigerator completeall as specified and directed |
107 | M&L for replacement of door switch push type suitable for any make/capacity model of refrigerator completeall as specified and directed |
108 | S&F Door handle suitable for Refrigerator any make / model / any cap of any completeall as specified and directed |
109 | S&F PVC bottle guard suitable for 165 to 310 ltr Refrigerator suitable for any make /model/any capacity completeall as specified and directed |
110 | S&F in replacement of condensing coil suitable for any make / model / refrigerator for the following capacity ( As per Sample ) :- (a) 300 / 310 ltrs |
111 | All as per Srl item No 110 here-in-before but165 ltrs to 210 ltrs. |
112 | S&F in replacement chilled tray plastic for suitable for any make / any model / any capacity refrigerator completeall as specified and directed |
113 | S&F in replacement of PVC gaskit magnetic type for suitable for any make / any model / any capacity refrigerator completeall as specified and directed |
114 | S&F in replacement of cooling fan motor with metallic blade for any cap / any type completeall as specified and directed |
115 | S&F Ice cube tray plastic complete all as specified and directed. |
116 | S&F vegetable tray plastic suitable for any make/any model/any capacity completeall as specified and directed |
117 | S&F toughened glass partition for any cap / any make / any model completeall as specified and directed |
118 | S&F timer switch for suitable for any make / any model /any size completeall as specified and directed |
119 | M&L for painting to refrigerator 310/300/316/165 ltrs by scraping the old paint and applying one coat of red oxide as primer and applying two coats of synthatic enamel paint of approved colour including writing SM No completeall as specified and directed |
120 | WATER COOLER : Disconnection of the compressor from suction and discharge line and taking out the sealed unit compressor from water cooler of any make , replacing the defective compressor with repaired compressor from any of the authorised repair workshop / manufacturer refixing the repaired compressor in the original position of the water cooler making all existing connection for following capacities :- (a) 40/80 , 60/120 ltrs capacity |
121 | All as per Srl item No 120 here-in-before but150 ltrs |
122 | S&F in replacement of new compressor hermetically sealed type with suitable rated capacity electric motor and shall be equipped with over load and relay, 230Volt, 50 Hz, single phase and confirming to IS-10617, suitable for water cooler 40/80 ltr capacity.Make: KIRLOSKAR/TECHUMSH/EMERSON COPLAND completeall as specified and directed |
123 | All as per Srl item No 122 here-in-before but60/120 ltr capacity. |
124 | All as per Srl item No 122 here-in-before but150 ltr capacity. |
125 | M&L cleaning of water cooler tank from inner side with soda / Acid and de-scaling of water cooler to remove by brushing and soldering the leaking places and prepare the leak proof and completeall as specified and directed |
126 | M&L for painting to water cooler of any capacity by applying two coats of synthetic enamel paint over a coat of red oxide primer of approved colour by spray machine after preparation of old surface and writing machine No with black paint completeall as specified and directed |
127 | Dismantling the blower motor of water cooler 1/32 HP capacity, 230 volts single phase and taking out burnt out copper winding wire from motor and M&L for rewinding the electric motor with super enameled copper winding wire of same size and gauge including insulation material, varnish and bush, shaft and refixing the motor complete & testing on full load including replacement of unserviceable spares completeall as specified and directed |
128 | All as per Srl item No 127 here-in-before but1/6HP for 150 ltr water cooler / AC |
129 | S&F in replacement of starting relay No. 522 / 1622 for water cooler Make : Tesla /Havells/EPCOS completeall as specified and directed |
130 | S&F in replacement of starting capacitor 40-60 mfd 220 Volts.Make : Tesla /Havells/EPCOS completeall as specified and directed |
131 | All as per Srl item No 130 here-in-before butfor capacitor 60-80 mfd 220 Volts.Make : Tesla /Havells/EPCOS |
132 | All as per Srl item No 130 here-in-before butfor Running capacitor 15 mfd, 415 volts .Make : Tesla /Havells/EPCOS |
133 | All as per Srl item No 130 here-in-before butforcapacitor 10 mfd, 415 volts .Make : Tesla /Havells/EPCOS |
134 | All as per Srl item No 130 here-in-before butforcapacitor 36 mfd, 415 volts .Make : Tesla /Havells/EPCOS |
135 | S&F in replacement of PVC float valve with rod and plastic ball suitable for 1/2" bore of water cooler. Make : Prayag / Pearl completeall as specified and directed |
136 | S&F in replacement of LDPE 25 mm dia flexible pipe heavy duty with suitable clamp completeall as specified and directed |
137 | S&F PVC pipe flexible type 32 mm dia for waste water draining completeall as specified and directed |
138 | S&F in replacementover load protector (OLP) for water cooler of any capacity completeall as specified and directed |
139 | S&F in replacement self closing push cock 15mm bore chromium plated brass heavy duty long body inner threaded completeall as specified and directed |
140 | S&F in replacement aluminium blade for blower motor of water cooler 80 ltrs to 150 ltrs completeall as specified and directed |
141 | S&F in replacementopen type relay : CAJ-2612 complete all as specified and directed |
142 | All as per Srl item No 141 here-in-before butCAJ-3612 |
143 | S&F in replacementthermostat of water cooler of any type make INDFOSS completeall as specified and directed |
144 | S&F in replacementblower motor 1/32 HP 230 volt suitable for water cooler complete with base frame/and rubber bush make AUE/GE for 60 to 150 ltrs completeall as specified and directed |
145 | Repair & rewinding blower motor 1/32 HP 230 volt suitable for water cooler for 60 to 150 ltrs water cooler and refixing the same position completeall as specified and directed |
146 | S&F in replacementdrip tray made of stainless steel complete suitable for water cooler any make of 40 to 150 ltr capacity completeall as specified and directed |
147 | Supply and fix water tank gasket for water cooler 40/80 ltr cap completeall as specified and directed |
148 | S&F wiring kit complete for water cooler completeall as specified and directed |
149 | DEEP FREEZER : Disconnection of the compressor from suction and discharge line and taking out the sealed unit compressor from Deep freezer of any make , replacing the defective compressor with repaired compressor from any of the authorised repair workshop / manufacturer refixing the repaired compressor in the original position of the Deep freezer making all existing connection for following capacities ;- (a) 200 / 300 Ltrs |
150 | All as per Srl item No 149 here-in-before but 400 / 500ltrs capacity. |
151 | Supply and fix in replacement of new compressor hermetically sealed with suitable rated capacity electric motor and shall be equipped with over load and relay, 230 volt , 50 Hz , single phase and confirming to IS-10617 , suitable for Deep freezer of capacity 200 / 300 Ltrs. Make : KIRLOSKAR/TECHUMSH/EMERSON COPLAND. |
152 | All as per Srl item No 151 here-in-before but400 / 500ltrs capacity. |
153 | M&L for Filling gas refrigerent R12/R22/R-404A in the sealed system of Deep Freezer any make and capacity after checking the leakage / pressure vacuminising flushing the sealed system including replacement of capacity Tube, copper pipe for jointing, Gas filter completeall as specified and directed |
154 | Supply & Fixing Voltage Stabilizer for 2 Ton AC Make : V-Guard VG 500 or equivalent in Microtek completeall as specified and directed |
155 | Supply & Fixing Voltage Stabilizer for 1.5 Ton AC Make : V-Guard VG 400 or equivalent in Microtekcompleteall as specified and directed |
156 | S&F in replacement starting relay as per sample completeall as specified and directed |
157 | S&F in replacement of main transformer 5 KVA capacity completeall as specified and directed |
158 | All as per Srl item No 157 here-in-before but2 / 3 / 4 KVA |
159 | All as per Srl item No 157 here-in-before but0.5 / 1KVA |
160 | WATER PURIFIER : Taking out of water purifier (Aqua guard) or any other make / modeland servicing , repair / over hauling of water puriferinstalled at cantt area for maintenance. (Spare parts will be measure and paid separetelly relevant items) completeall as specified and directed |
161 | S&F in replacement of pre filter candle (as per sample) completeall as specified and directed |
162 | S&F in replacement of Activated Carbon completeall as specified and directed |
163 | S&F in replacement of PCB circuit electric plate completeall as specified and directed |
164 | S&F in replacementultra violet lamp unit completeall as specified and directed |
165 | S&F in replacement of PVC pipe nylon braided heavy duty suitable for water partition inletconnection and as required at site completeall as specified and directed |
166 | S&F in replacement of chromomum plate tee 15/8 mm for existing GI pipe connection completeall as specified and directed |
167 | DESERT COOLER: Servicing / Disconnection desert cooler of kit fan from desert cooler for repairing including cleaning,greasing,oiling , welding or M"seal at leaking place and refixing back after repair in original position including replacement of unserviceable spares. ( parts to be replaced will be measured and paid separately under elevant items) completeall as specified and directed |
168 | S&F in repair desert cooler fan motor any type/any model/make completeall as specified and directed |
169 | S&F in replacement of capacitor 4 mfd for kit fan / Exhaust fan completeall as specified and directed |
170 | S&F in replacement of PVC water distributer 3 way / 4 way for desert cooler of any size / capacity completeall as specified and directed |
171 | S&F in replacement of PVC elbow suitable for desert cooler of any size / capacity completeall as specified and directed |
172 | S&F in replacement of PVC flexible pipe 15 mm dia suitable for water distribution system of Desert cooler of any size / capacity completeall as specified and directed |
173 | S&F in replacement of front grill plastic type desert cooler with necessary nut,bolts, and washers etc, all as directed. Make : conark completeall as specified and directed |
174 | S&F in replacement of Vertical lifting pumps 1/70 HP, 230 Volts single phase. Make : CG / Bajaj completeall as specified and directed |
175 | S&F in replacement of Sumersible pump suitable for desert cooler complete upto 4000 cumMake : CG / Bajaj completeall as specified and directed |
176 | S&F in replacement of wood wool padding of desert cooler of suitable size in wire net complete weight not less than 450 gms completeall as specified and directed |
177 | S&F in replacement of wood wool padding of Industrial desert cooler of suitable size in wire net complete weight not less than 450 gms. completeall as specified and directed |
178 | S&F in replacement side shutter (set of three) for desert cooler of as per sample 22 gauge PGI sheets grill type completeall as specified and directed |
179 | Supply &installnewdesert cooler 4000 cum per hour,electric driven, 1 phase, 240 volts, AC heavy duty long body exhaust fan motor with , submersible water pump, ISI marked 3 core 1.50 sqmm pvc copper cable of minium 2 mtr long with plug top and control switches etc completeall as specified and directed |
180 | Supply and fix fan motor copper wounded suitable for desert cooler 230 volts, 50 Hz, single phase AC supply four speed 180 watts of 450 mm sweep complete with fan blade and legs, 4000 Cum complete. Make : CG/Bajaj/Havells completeall as specified and directed |
181 | Supply and fix fan motor copper wounded suitable for Industrial desert cooler 230 volts, 50 Hz, single phase AC supply four speed 180 watts of 450 mm sweep complete with fan blade and legs 6000 Cum completeall as specified and directed Make : CG/Bajaj/Havells |
182 | S&F in replacement of Mettalic fan blade for desert cooler motor 4000 Cum completeall as specified and directed |
183 | S&F in replacement of Mettalic fan blade for Industrial desert cooler motor 6000 Cum completeall as specified and directed |
184 | S&F in replacement of 3 pin plug top 5 Amps. Make : Anchor / Kinjal completeall as specified and directed |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy