Annual Maintenance And Repair Of Electrical Works At Bijlighar Kesco, Kanpur.-2 Wiring Point For Light With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Pvc Conduit With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand C, Kanpur Nagar-Uttar Pradesh

Kanpur Electricity Supply Co Limited-KESCO has published Annual Maintenance And Repair Of Electrical Works At Bijlighar Kesco, Kanpur.-2 Wiring Point For Light With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Pvc Conduit With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand C. Submission Date for this Tender is 25-05-2022. Electrical Maintenance Tenders in Kanpur Nagar Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32108556
Annual Maintenance And Repair Of Electrical Works At Bijlighar Kesco, Kanpur.-2 Wiring Point For Light With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Pvc Conduit With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand C
Open Tender
Indian
Uttar Pradesh
Kanpur Nagar
25-05-2022

Tender Details

Annual Maintenance And Repair Of Electrical Works At Bijlighar Kesco, Kanpur.-2 Wiring Point For Light With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Pvc Conduit With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit On Surface, Gp Box, Piano Type Switch And Ceiling Rose / Angle / Batten Holder On 3 Mm. Thick Phenolic Laminated Backelite Sheet Etc. Complete In All Respect As Per Direction Of E / I. ( Pwd 121-C ) 3 Wiring Point For Fan / Fresh Air Fan ( Light Duty Exhaust Fan ) With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In But In Pvc Conduit With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit On Surface, Piano Type Switch And Ceiling Rose / Angle / Batten Holder On 3 Mm. Thick Phenolic Laminated Backelite Sheet Etc. Complete In All Respect As Per Direction Of E / I. ( Pwd 123-C ) 4 Wiring Point For Plug With 1 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Pvc Conduit With 1.5 Sq. Mm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit On Surface, Piano Type Switch And Ceiling Rose / Angle / Batten Holder On 3 Mm. Thick Phenolic Laminated Backelite Sheet Etc. Complete In All Respect As Per Direction Of E / I. ( Pwd 124-C ) 5 Wiring Point For Call Bell With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In But In Pvc Conduit With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit On Surface, Piano Type Switch And Ceiling Rose / Angle / Batten Holder On 3 Mm. Thick Phenolic Laminated Backelite Sheet Etc. Complete In All Respect As Per Direction Of E / I. ( Pwd 125-C ) 6 Wiring Point For Exhaust Fan With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Pvc Conduit With 1.5 Sq. Mm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit On Surface, 15A Piano Type Switch And Ceiling Rose / Angle / Batten Holder On 3 Mm. Thick Phenolic Laminated Backelite Sheet Etc. Complete In All Respect As Per Direction Of E / I. ( Pwd 127-C ) 7 Wiring Point For Light With 1.5 Sq. Mm. Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Existing Concealed Conduit With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit On Surface, Gp Box, Piano Type Switch And Ceiling Rose / Angle / Batten Holder On 3 Mm. Thick Phenolic Laminated Backelite Sheet Etc. Complete In All Respect As Per Direction Of E / I. ( Pwd 174-C ) 8 Wiring Point For Ceiling Fan With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Existing Concealed Conduit With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit On Surface, Gp Box, Piano Type Switch And Ceiling Rose / Angle / Batten Holder On 3 Mm. Thick Phenolic Laminated Backelite Sheet Etc. Complete In All Respect As Per Direction Of E / I. ( Pwd 177-C ) 9 Supply And Wiring Of Submain With Two Number 4 Sq.Mm. Frlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Pvc Conduit On Surface, With One Number 2.5 Sq. Mm. Multistrand Copper Drawn In Conduit Complete In All Respect. ( Pwd 211-C ) 10 Supply And Wiring Of Submain With Two Number 6 Sq.Mm. Frlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Pvc Conduit On Surface, With One Number 2.5 Sq. Mm. Multistrand Copper Drawn In Conduit Complete In All Respect. ( Pwd 212-C ) 11 Supply And Wiring Of Submain With Two Number 4 Sq.Mm. Frlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In Existing Pvc Conduit On Surface, With One Number 2.5 Sq. Mm. Multistrand Copper Drawn In Conduit Complete In All Respect. ( Pwd291-A ) 12 Supply And Wiring Of Submain With 4 Number 16 Sq.Mm. Frlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In Existing Pvc Conduit On Surface Complete In All Respect. ( Pwd 291-L ) 13 S&F Of 32 Amp. Double Pole Change Over Switch On 25Mm X 25Mm X 3Mm Angle Iron Frame, Including The Cost Of Labour, T&P, Painting And Other Material Required For Proper Completion Of The Work As Per Direction And Satisfaction Of Engineer In Charge. ( Pwd 374 ) 14 S&F Of 32 Amp. Four Pole Change Over Switch On 25Mm X 25Mm X 3Mm Angle Iron Frame, Including The Cost Of Labour, T&P, Painting And Other Material Required For Proper Completion Of The Work As Per Direction And Satisfaction Of Engineer In Charge. ( Pwd 376 ) 15 S&F Of 63 Amp. Four Pole Change Over Switch On 40Mm X 40Mm X 6Mm Angle Iron Frame, Including The Cost Of Labour, T&P, Painting And Other Material Required For Proper Completion Of The Work As Per Direction And Satisfaction Of Engineer In Charge. ( Pwd 377 ) 16 S&F Of 100 Amp. Four Pole Change Over Switch On 40Mm X 40Mm X 6Mm Angle Iron Frame, Including The Cost Of Labour, T&P, Painting And Other Material Required For Proper Completion Of The Work As Per Direction And Satisfaction Of Engineer In Charge. ( Pwd 378 ) 17 S&F Of 200 Amp. Four Pole Change Over Switch On 50Mm X 50Mm X 6Mm Angle Iron Frame, Including The Cost Of Labour, T&P, Painting And Other Material Required For Proper Completion Of The Work As Per Direction And Satisfaction Of Engineer In Charge. ( Pwd 379 ) 18 Erection And Testing Of Exhaust Fan On The Existing Hole With Suitable Size Of Rag Bolts, Nuts And Washers Etc., Complete In All Respect. ( Pwd 1120 ) 19 Making Hole In The Wall For Exhaust Fan And Finishing Properly Complete In All Respect. ( Pwd 1121 ) 20 Supply And Fixing Of Power Plug With 15A / 250 Volt Flush Type Switch And 5 Pin 15A / 250V Flush Type Universal Socket In Suitable M.S. Box Of 175Mm X 100Mm X 50Mm Size With Phenolic Laminated Bakelite Sheet Cover 3Mm Thick Fixed With Brass Machine Screw And Cup Washer. ( Pwd 1139 ) 21 Erection And Testing Of Ceiling Fan And Regulator Etc. Excluding Supply Of Down Rod, Complete In All Respect. ( Pwd 1115 ) 22 Supply And Fixing Of Call Bell Of Approved Make On Polished Mdfeg / Teak Ply Board Including Making Connections Etc. Complete In All Respect. ( Pwd 1101 ) 23 S&F Of 6 Amp To 32 Amp. Mcb ( 10 Ka ) C Curve. ( Pwd 1002-B ) 24 S&F Of 40 Amp. Dp Mcb ( 10 Ka ) C Curve. ( Pwd 1010-B ) 25 S&F Of 63 Amp. 4 Pole Mcb ( 10 Ka ) C Curve. ( Pwd 1020-B, Cat-B ) 26 S&F Of 80 To 100 Amp 4 Pole Mccb ( 16 Ka ) Thermal Magnetic Release. ( Pwd 1021-B ) 27 S&F Of 32 Amp. 240 V Spn Metal Clad Rewireable Type Switch Fuse Unit On M.D.F.E.G. / Teak Wood Board Complete In All Respects. ( Pwd 302 ) 28 S / F Of 32 Amp , 415 Volt Metal Clad T, P, Rewireable Type Switch Fuse Unit On Angle Iron Bracket Complete In All Respect. ( Pwd 321 ) 29 S&F Of 63 Amp. 415 V Metal Clad Tp Hrc Type Switch Fuse Unit Complete With Hrc Fuse On Angle Iron Bracket Complete In All Respect. ( Pwd 323 ) 30 S&F Of 100 Amp. 415 V Metal Clad Tp Hrc Type Switch Fuse Unit Complete With Hrc Fuse On Angle Iron Bracket Complete In All Respect. ( Pwd 324 ) 31 S / R Of 40 Watts H.D. Electronic Ballast ( Choke ) Having Minimum 06 Months Guarantee Silvania Laxman / Bajaj Or Equivalent Make As Per Isi Including Cost Of All Labour Material, As Per Approved Sample. T&P Etc. Required For Proper Completion Of The Work. ( C.S.I. 22.48 ) 32 S / R Of 40 Watts 4’ Long Tube Light Silvania Laxman / Bajaj Or Equivalent Make As Per Isi Including Cost Of All Labour Material, T&P Etc. Required For Proper Completion Of The Work. ( C.S.I. 22.47 ) 33 Supply & Fixing Of Led Tube Light Fitting 18Watt -4Ft. Of Crompton Or Equivalent Make Including Labour T&P Etc. ( Nsi ) 34 S / R Tube Light Holder Of Heavy Quality Including Cost Of All Labour Material, T&P Etc. Required For Proper Completion Of The Work. ( C.S.I. 22.49 ) 35 S / R Of Bakelite Angle Holder Of Ssk Or Equivalent Make Of Approved Quality Including Cost Of All Labour Material, T&P Etc. Required For Proper Completion Of The Work. ( C.S.I 22.51 ) 36 Supply And Fixing Of Led Street Light Fitting Having Dia Cast Aluminum Body And Diffuser With Driver Set Suitable For 110 To 130 Watt. Confirming To Ip 66 Production Complete In All Respect. ( Pwd 1424 ) 37 S / R Of Regulator For Ceiling Fan Of Gec Or Equivalent Make Including Cost Of All Labour Material, T&P Etc. Required For Proper Completion Of The Work. ( C.S.I. 22.60B ) 38 Rewinding Of Burnt Ceiling Fan With Approved Copper Wire Including Cost Of All Materials, Labourand T&P Etc. Complete ( Burnt Wire Will Not Be Taken Back. ) ( C.S.I. 22.102 ) 39 S / R Of Burnt Damaged Condenser Of Approved Quality Including Cost Of All Labour Material, T&P Etc. Required For Proper Completion Of The Work. ( C.S.I. 22.61 ) 40 ( A ) 2.5 M.Fd 41 ( B ) 4.5 M.Fd 42 Disconnecting And Opening Of The Ceiling Fan, Its Greasing After Cleaning The Bearing Or Bush And Shaft With Oil / Petrol, Its Testing And Fixing Of The Same Including Cost Of All Materials, Labour And T&P Etc. Required For Proper Completion Of Work. ( C.S.I.22.59 ) 43 S / R Of Damage Bearing Of Ceiling Fan Including Cost Of All Labour Material, T&P Etc.Required For Proper Completion Of The Work. ( C.S.I. 22.62 ) 44 S / R Of 250 Watts Sodium Lamp Of Approved Quality And Sample Including Cost Of All Labour Material, T&P Etc. Required For Proper Completion Of The Work. ( C.S.I.22.66 A ) 45 S / R Of 250 Watt Sodium Choke Including Cost Of All Labour Material, T&P Etc. Required For Proper Completion Of The Work. ( C.S.I. 22.67 ) 46 Supply & Fixing Ceiling Fan Of High Speed 48” Of Crompton Or Equivalent Make Including Labour & Tp Etc. ( Nsi ) 47 Supply & Fixing Fresh Air Fan Of 200Mm Of Crompton Or Equivalent Make Including Labour & Tp Etc. ( Nsi ) 48 Supply & Fixing Wall Fan Of High Flow Wave 400Mm Of Crompton Or Equivalent Make Including Labour & Tp Etc. ( Nsi ) 49 Supply & Fixing A.C Box With M.C.B. Of L&T Or Equivalent Make Including Labour & Tp Etc. ( Nsi ) 50 Supply & Fixing Of Led Bulb Of 9 Watt Of Crompton Or Equivalent Make Including Labour T&P Etc. ( Nsi ) 51 Supply & Fixing Of Led False Ceiling Light Of 12 Watt Of Crompton Or Equivalent Make Including Labour & Tp Etc. ( Nsi ) 52 Supply & Fixing Chord Less Call Bell Of Approved Quality As Per Direction Of Engineer In Charge. ( N.S.I. ) 53 Attending To Petty Maintenance Service Like Plumbing Service, Welder Service, Mason Service And Carpenter Service Required As Below. ( C.S.I22.109 ) 54 ( A ) Job Attending By One No. Plumber / Welder / Mason / Carpenter With One No. Helper Per Hour Or Part Of An Hour. 55 ( B ) Job Attending By One No. Plumber / Welder / Mason / Carpenter With Two No. Helper Per Hour Or Part Of An Hour.

Key Value

Document Fees
INR 1180 /-
EMD
INR 2000.0 /-
Tender Value
INR 1.93 Lakhs /-

BOQ Items

Name of Work: < ANNUAL M AND R OF ELECTRICAL WORKS AT BIJLIGHAR, KESCo, KANPUR..>
Sl. No. Item Description
1Civil work:
2Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit on surface, GP Box, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD 121-C)
3Wiring point for fan /fresh air fan (light duty exhaust fan)with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit on surface, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD 123-C)
4Wiring point for plug with 1 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit on surface, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD 124-C)
5Wiring point for call bell with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit on surface, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD 125-C)
6Wiring point for exhaust fan with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit on surface, 15A piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD 127-C)
7Wiring point for light with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable in existing Concealed conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit on surface, GP Box, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD 174-C)
8Wiring point for ceiling fan with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in existing Concealed conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit on surface, GP Box, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD 177-C)
9Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia PVC conduit on surface, with one number 2.5 sq. mm. multistrand copper drawn in conduit complete in all respect. (PWD 211-C)
10Supply and wiring of submain with two number 6 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia PVC conduit on surface, with one number 2.5 sq. mm. multistrand copper drawn in conduit complete in all respect. (PWD 212-C)
11Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in existing PVC conduit on surface, with one number 2.5 sq. mm. multistrand copper drawn in conduit complete in all respect. (PWD291-A)
12Supply and wiring of submain with 4 number 16 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in existing PVC conduit on surface complete in all respect. (PWD 291-L)
13S&F of 32 Amp. double pole change over switch on 25mm x 25mm x 3mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. (PWD 374)
14S&F of 32 Amp. four pole change over switch on 25mm x 25mm x 3mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. (PWD 376)
15S&F of 63 Amp. four pole change over switch on 40mm x 40mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. (PWD 377)
16S&F of 100 Amp. four pole change over switch on 40mm x 40mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. (PWD 378)
17S&F of 200 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. (PWD 379)
18Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts, nuts and washers etc., complete in all respect. (PWD 1120)
19Making hole in the wall for exhaust fan and finishing properly complete in all respect. (PWD 1121)
20Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. (PWD 1139)
21Erection and testing of ceiling fan and regulator etc. excluding supply of down rod, complete in all respect. (PWD 1115)
22Supply and fixing of call bell of approved make on polished MDFEG / Teak ply board including making connections etc. complete in all respect. (PWD 1101)
23S&F of 6 Amp to 32 Amp. MCB (10 KA) C Curve. (PWD 1002-B)
24S&F of 40 Amp. DP MCB (10 KA) C Curve. (PWD 1010-B)
25S&F of 63 Amp. 4 pole MCB(10 KA) C Curve. (PWD 1020-B, CAT-B)
26S&F of 80 to 100 Amp 4 pole MCCB (16 KA) Thermal Magnetic release. (PWD 1021-B)
27S&F of 32 Amp. 240 V SPN metal clad rewireable type switch fuse unit on M.D.F.E.G. / Teak wood board complete in all respects. (PWD 302)
28S/F of 32 Amp ,415 volt metal clad T,P,rewireable type switch fuse unit on angle iron bracket complete in all respect. (PWD 321)
29S&F of 63 Amp. 415 V metal clad TP HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect. (PWD 323)
30S&F of 100 Amp. 415 V metal clad TP HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect. (PWD 324)
31S/R of 40 watts H.D. electronic ballast (choke) having minimum 06 months guarantee Silvania Laxman / Bajaj or equivalent make as per ISI including cost of all labour material, as per approved sample. T&P etc. required for proper completion of the work. (C.S.I. 22.48)
32S/R of 40 watts 4’ long tube light Silvania Laxman / Bajaj or equivalent make as per ISI including cost of all labour material, T&P etc. required for proper completion of the work. (C.S.I. 22.47)
33Supply & fixing of LED Tube light fitting 18watt -4Ft. of Crompton or equivalent make including labour T&P etc. (NSI)
34S/R tube light holder of heavy quality including cost of all labour material, T&P etc. required for proper completion of the work. (C.S.I. 22.49)
35S/R of bakelite angle holder of SSK or equivalent make of approved quality including cost of all labour material, T&P etc. required for proper completion of the work. (C.S.I 22.51)
36Supply and fixing of LED street light fitting having dia cast aluminum body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 production complete in all respect. (PWD 1424)
37S/R of regulator for ceiling fan of GEC or equivalent make including cost of all labour material, T&P etc. required for proper completion of the work. (C.S.I. 22.60b)
38Rewinding of burnt ceiling fan with approved copper wire including cost of all materials, labourand T&P etc. complete (Burnt wire will not be taken back.) (C.S.I. 22.102)
39S/R of burnt damaged condenser of approved quality including cost of all labour material, T&P etc. required for proper completion of the work. (C.S.I. 22.61)
40(a) 2.5 M.Fd
41(b) 4.5 M.Fd
42Disconnecting and opening of the ceiling fan, its greasing after cleaning the bearing or bush and shaft with oil/petrol, its testing and fixing of the same including cost of all materials, labour and T&P etc. required for proper completion of work. (C.S.I.22.59)
43S/R of damage bearing of ceiling fan including cost of all labour material, T&P etc.required for proper completion of the work. (C.S.I. 22.62)
44S/R of 250 watts sodium lamp of approved quality and sample including cost of all labour material, T&P etc. required for proper completion of the work. (C.S.I.22.66 a)
45S/R of 250 watt sodium choke including cost of all labour material, T&P etc. required for proper completion of the work. (C.S.I. 22.67)
46Supply & fixing ceiling fan of high speed 48” of Crompton or equivalent make including labour & TP etc. (NSI)
47Supply & fixing fresh air fan of 200mm of Crompton or equivalent make including labour & TP etc. (NSI)
48Supply & fixing wall fan of high flow wave 400mm of Crompton or equivalent make including labour & TP etc. (NSI)
49Supply & fixing A.C box with M.C.B. of L&T or equivalent make including labour & TP etc. (NSI)
50Supply & fixing of LED Bulb of 9 watt of Crompton or equivalent make including labour T&P etc. (NSI)
51Supply & fixing of LED false ceiling light of 12 watt of Crompton or equivalent make including labour & TP etc. (NSI)
52Supply & Fixing Chord less call bell of approved quality as per direction of Engineer in charge. (N.S.I.)
53Attending to petty maintenance service like plumbing service, welder service, mason service and carpenter service required as below. (C.S.I22.109)
54(a) Job attending by one no. Plumber/welder/mason/ carpenter with one no. helper per hour or part of an hour.
55(b) Job attending by one no. Plumber/welder/mason/ carpenter with two no. helper per hour or part of an hour.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail