Repair, Maintenance, Servicing, Overhauling And Connected Works For Summer Appliances Including Replacement Of Old Unserviceable Point Wiring And Sub Main Wiring, Ceiling Fan, Exhaust Fan And Connected Work At Af Stn, gurgaon-Haryana

Military Engineer Services-MES has published Repair, Maintenance, Servicing, Overhauling And Connected Works For Summer Appliances Including Replacement Of Old Unserviceable Point Wiring And Sub Main Wiring, Ceiling Fan, Exhaust Fan And Connected Work At Af Stn. Submission Date for this Tender is 01-06-2022. Electrification Work Tenders in gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

32094911
Corrigendum : Repair, Maintenance, Servicing, Overhauling And Connected Works For Summer Appliances Including Replacement Of Old Unserviceable Point Wiring And Sub Main Wiring, Ceiling Fan, Exhaust Fan And Connected Work At Af Stn
Open Tender
Indian
Haryana
gurgaon
01-06-2022

Tender Details

Repair, Maintenance, Servicing, Overhauling And Connected Works For Summer Appliances Including Replacement Of Old Unserviceable Point Wiring And Sub Main Wiring, Ceiling Fan, Exhaust Fan And Connected Work At Af Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-May-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-06-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 96000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR, MAINTAINANCE, SERVICING, OVERHAULING AND CONNECTED WORKS FOR SUMMER APPLIANCES INCLUDING REPLACEMENT OF OLD UNSERVICABLE POINT WIRING AND SUB MAIN WIRING CEILING FAN,EXHAUST FAN, AIR CIRCULATOR,ELECTRIC METER AND CONNECTED WORK AT AF STNGURGAON UNDER GE (P) AF GURGAON.
Sl. No. Item Description
1Schedule of Works
2Taking down and serviceing of ceiling fan1200/1400 mm sweep at site and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt, rubber real bush gun metal ball bearing capacitor split and reassembling the fan complete including testing after assembling and connecting to electric systemcomplete all as specified and as directed by Engr-in-Charge.NOTE:- Rates of bearing, capacitor, blades & painting will be paid seperately in the concered item of schedule.
3All as per srl item No 1 above but for wall mounting fan plastic type of size 400/450mm sweep complete.
4All as per srl item No 1 above but for exhaust fan of any size complete.
5Taking down carefully AC single phase 220/230volt ceiling fan 1200/1400mm sweep single phase complete at site for rewinding and replacement of unserviceable parts i.e Capacitor, PVC connector, MS galvanised check nut, ball bearing, rubber pads, PVC strip clamps includingservicing such as removing dust & dirt brushing, rubbing with cotton waste, , washing with detergent powder to fan blades, greasing bearing with ball bearing grease & washer packing, checking of bolts/nuts, washer check nuts split pin rubber packing and rubber seal etcincluding testing after assembling and connecting to electric systemcomplete all as specified and as directed by Engr-in-Charge. Note :1.Rates of winding and replacement of any unserviceable parts mentioned above required to make the fan in serviceable condition are include in the quoted rate.2. Old winding of the fans will be destroyed/damaged by the department before handing over the fan to contractor for repair.3.After repair contractor will be fully responsible for checking of copper winding and thereafter the same will be assembed, re-hanging and electric connection complete. 4. Rates of bearing, bush, capacitor, blades & painting will be paid seperately in the concered item of schedule.
6All as per srl item No 4 above but for wall mounting fan plastic type of size 400mm sweep complete.
7All as per srl item No 4 above but for wall mounting fan plastic type of size 450mm sweep complete.
8All as per srl item No 4 above but for exhaust fan of size 250mm sweep plastic type square/round shape complete .
9All as per srl item No 4 above but forexhaust fan300mm sweep complete.
10All as per srl item No 4 above but forexhaust fan 450mm sweep complete.
11All as per srl item No 4 above but for exhaust fan 600mm sweep complete.
12All as per srl item No 4 above but for air circulator wall mounting fan metallic type 450mm sweep complete.
13All as per srl item No 4 above but for air circulator wall mounting fan metallic type 600mm sweep complete.
14S&F in replacement capacitor 2.5 mfd + 5%, 220/230 volts AC, 50 c/s complete all as specified and as directed by Engr-in-Charge. Make: Usha/Epcos/Tibcon.
15S&F in replacement capacitor 3.15 mfd + 5%, 220/230 volts AC, 50 c/s complete all as specified and as directed by Engr-in-Charge. Make: Usha/Epcos/Tibcon.
16S&F in replacement capacitor 4 mfd + 5%, 400/440 volts AC, 50 c/s complete all as specified and as directed by Engr-in-Charge. Make: Usha/Epcos/Tibcon.
17S&F in replacement Electric cable PVC insulated with copper conductor (flexible cable) size 23/0.0076 twin core for connecting fan to electric system, complete all as specified and as directed by Engr-in-Charge.
18M & L in replacement for Remetaling to worn out shaft of fan motor turning complete to obtain the standard dia of shaft for fixing standard size bearing/bushes to ceiling fan of 1200/1400mm sweep of any make complete all as specified and as directed by Engr-in-Charge.
19Taking down and Spray painting to AC ceiling fan 1200/1400mm sweep any make complete to motor assy, down rods, blades with ISI marked white/brown synthetic enamel paint as approved by Engr-in-Charge after preparation of surface including filling cavities with filler, writing of MES No complete and refixing the same in existing location after painting complete all as specified and as directed by Engr-in-charge.
20Taking down metallic type wall mounting fan of size 400/450mm sweep in situ for spray painting with ISI marked OG/brown/black synthetic enamel paint as directed by Engr-in-charge after preparation of surface and refixing the same in existing location after painting complete all as specified and as directed by Engr-in-charge.
21All as per item No 19 hereinbefore but for exhaust fan 300mm.
22All as per item No 19 hereinbefore but for exhaust fan exceeding 300mm and upto 450mm.
23All as per item No 19 hereinbefore but for exhaust fan exceeding 450mm and upto 600mm.
24All as per item No 19 hereinbefore but for air circulator wall mounting fan of size 450 to 600mm .
25S&F in replacement Canopies for AC ceiling fan of size 1200/1400mm sweep for any make of fan complete all as specified and as directed by Engr-in-charge.
26S&F in replacement down rods for ceiling fan 1200/1400mm sweep of size 2.5" long duly painted with white synthetic enamel paint complete all as specified and as directed by Engr-in-Charge.
27S & F in replacement Hanging clamp suitable for ceiling fan of size 1200/1400mm of any make complete with nuts, bolts, rubber reel and locking pin complete all as directed by Engr-in-Charge.
28S&F in replacement steptype elctronic fanregulator in replacement Modulartype 2 Module, single phase 220 V, complete all as specified and as directed by Engr-in-Charge.
29S&F in replacement steptype elctronic fan regulator in replacement Flush type, single phase 220 V, complete all as specified and as directed by Engr-in-Charge.
30S&F in replacement louvers only for exhaust fan of size 300mm sweep made out of MS sheet22 gauge complete all as specified and as directed by Engr-in-Charge.
31S&F in replacement louvers only for exhaust fan of size 450mm sweep made out of MS sheet22 gauge complete all as specified and as directed by Engr-in-Charge.
32M&L in replacement fan blade (set of 03) suitable for 1200 mm sweep complete all as specified and as directed by Engr-in-Charge.
33M&L in replacement fan blade (set of 03) suitable for 1400 mm sweep complete all as specified and as directed by Engr-in-Charge.
34S&F in replacement wall mountedfans blades (set of 03) suitable for400/450 mm sweep any make and suitable colour including taking down complete all as specified and as directed by Engr-in-Charge.
35S&F in replacement exhaust fans blades suitable for300/450 mm sweep any make and suitable colour including taking down complete all as specified and as directed by Engr-in-Charge.
36Supply and fix in replacement Ball bearing suitable size of ceiling fan any type and size complete all as specified and as directed by Engr-in-Charge. Make : SKF/PNB/TATA
37Supply and fix in replacement Ball bearing suitable size of Exhaust fan any type and size complete all as specified and as directed by Engr-in-Charge. Make : SKF/PNB/TATA
38Supply and fix in replacement Ball bearing suitable size of wall maunted fan any type and size complete all as specified and as directed by Engr-in-Charge. Make : SKF/PNB/TATA
39Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody for re-use at site/Sch of credit and making good disturbed surface of walls, floors, etc., complete all as specified and as directed by Engineer-in-Charge.
40M&Lforpoint wiring complete with 1.5 Sqmm (nominal area) PVC insulated, multi stranded, HRFR copper conductor cable unsheathed in and including PVC conduit with all fittingsmedium grade ISI Marked and PVCinsulated HRFR copperconductor cable of size 1.5 sq mm as earth wire, connected to common earth dolly suitable formounting modular switches including modular metal flush boxes and modular face plate complete all as specified and as directed by Engr-in-charge, (The works includes cutting of chasis and making good disturbed surfaces and rate deemed to included in quated rate):-
41One light pointcontrolled by one way one switch SP 5 Amps , 240 V.
42One ceiling fan / Exhaust point controlled by one way one switch SP 5 Amps, 240 V.
43One light point controlled by two 2 wayswitch SP 5 Amps ,240 V.
44One switch socket outlet 3 Pin, 5 Amps, SP on independent board.
45One switch socket outlet 3 Pin, 5 Amps, SP on sameboard.
46One bell point controlled by one way one switch SP 5 Amps , 240 V.
47All as per the item No 39 here in before but with 2.5 Sqmm cable for 3 pin 15 Amps socket complete all as specified and as directed by Engineer-in-Charge.
48S&F in replacement modular socket outlet 6A, 2/3 pin combined 2 module, complete all as specified and as directed by Engineer-in-Charge.
49S&F in replacement modular socket outlet 6A/16A, 2/3 pin combined 2 module, complete all as specified and as directed by Engineer-in-Charge.
50S&F in replacement modular switch 1 way 6 Amps 1 module, complete all as specified and as directed by Engineer-in-Charge.
51S&F in replacementmodular switch 2 way 6 Amps 1 module complete all as specified and as directed by Engineer-in-Charge.
52S&F in replacementmodular switch 1 way 16 Amps 1 module, complete all as specified and as directed by Engineer-in-Charge.
53S&F in replacement ceiling rose 3 phase/PVC/ polycarbonate isolated body,complete all as specified and as directed by Engineer-in-Charge.
54S&F in replacement modular bell push switch 1 way 6 Amps 1 module, complete all as specified and as directed by Engineer-in-Charge.
55M&L for Point wiring complete with HRFR PVC insulated unsheathed , 1100 V grade conforming to IS 694 ,1.5 Sqmm (Norminal area) multistranded , copper conductor cable drawn through in non metallic rigid PVC conduit medium grade , minimum 20 mm dia conceled in wall , ISI Marked, and connect accessories, mounting onsuface of walls / ceilings /roofs etc with shunken boxanodised concealed in suface of wall , 3 mm thick laminatedplastic sheet cover for mounting of switches, sockets outlets, regulators etc,fixed by suitable size of 04 Nos cadmium screwes including provision of HRFR PVC insulated unsheathed 1.5 Sqmm muiltistranded green colour copper conductor cableas earth connectivityand connecting to common earth dolly complete all as specified and as directed by Engineer-in-Charge, (The works includes cutting of chasis and making good disturbed surfaces and rate deemed to included in quated rate):-
56One light pointcontrolled by one way one switch SP 5 Amps , 240 V.
57One ceiling fan/Exhaustpoint controlled by one way one switch SP 5 Amps, 240 V.
58One switch socket outlet 3 Pin, 5 Amps, SP on independent board.
59One switch socket outlet 3 Pin, 5 Amps, SP on sameboard.
60One bell point controlled by one way one switch SP 5 Amps , 240 V.
61One light point controlled by two 2 wayswitch SP 5 Amps , 240 V.
62All as per the item No 48 here in before but with 2.5 Sqmm cable for 3 pin 15 Amps socket complete all as specified and as directed by Engineer-in-Charge.
63S&F in replacement switch piano flush type single pole one way , 5 Amps , 240V grade ISI marked , complete all as specified and as directed by Engineer-in-Charge.
64S&F in replacement switch piano flush type single pole oneway , 15 Amps , 240V grade ISI marked, complete all as specified and as directed by Engineer-in-Charge.
65S&F in replacement socket outlet 2 in 1 ,3 pin 5 Amps flush type ISI marked, complete all as specified and as directed by Engineer-in-Charge.
66S&F in replacementsocket outlet 2 in 1 ,3 pin 5 and15 Amps flush typeISI marked, complete all as specified and as directed by Engineer-in-Charge.
67S&F in replacement switch bell push piano flush type single pole one way , 5 Amps , 240V grade ISI marked, complete all as specified and as directed by Engineer-in-Charge.
68S&F in replacement switch piano flush type single pole two way , 5 Amps , 240V grade ISI marked, complete all as specified and as directed by Engineer-in-Charge.
69Taking out old U/S submain wiring of any size and removing materials to store or as sch of credit including making good of existing surfaces complete all as specified and as directed.
70M&L in replacement of sub main wiring with multistranded FR copper conductor cable PVC sheathed in and including concealed suitable size PVC conduit medium grade with fittings and two runs of6 Sqmm andone run of 4 Sqmm FR copper conductor as earth wire and connected to earth dollyall as specified and as directed by Engr-in-Charge. ( The item includes cutting Chasis and making good the disturbed surfaces).
71M&L in replacement of sub main wiring with multistranded FR copper conductor cable PVC sheathed in and including concealed suitable size PVC conduit medium grade with fittings and two runs of10 Sqmm andone run of 6 Sqmm FR copper conductor as earth wire and connected to earth dollyall as specified and as directed by Engr-in-Charge. ( The item includes cutting Chasis and making good the disturbed surfaces).
72S&F in replacement of Gong Bell, singlephase 12Inch, 230 volt AC, 50 HZ, complete all as specified and as directed by Engineer-in-Charge. .
73S&F in replacement of Ding DongBell, singlephase, 230 volt AC, 50 HZ, complete all as specified and as directed by Engineer-in-Charge.
74S&F in replacement,Battenholderbakelite AC, 220 V, complete all as specified and as directed by Engineer-in-Charge.
75S&F in replacement of sheet metal enclosure single pole and neutral 4 way Double door with two pin and earth plug & socket complete with one single pole MCB 240 Volts 20 Amps, complete all as specified and as directed by Engineer-in-Charge.
76S&F in replacement of sheet metal enclosure single pole and neutral 8 way Single door with two pin and earth plug & socket complete with one single pole MCB 240 Volts 20 Amps, complete all as specified and as directed by Engineer-in-Charge.
77S&F in replacement of metal enclosure for MCB"s (D.B) 12 way (SPN) 200 Amps rated bus bar complete all as specified and as directed. Cat No- DHDPSHODRW08 MakeHavells or equivalent out of makes specified in list of makes.
78S&F in replacement of sheet metal enclosure triple pole and neutral415 Volts 6 way 200 amp rated Double door, complete all as specified and as directed by Engineer-in-Charge. Cat N0- DHDLVDRWG OFO04 MakeHavells or equivalent out of makes specified in list of makes.
79S&F in repairs sheet metal enclosure triple pole and neutral vertical Loadline 415 Volts 8 way (TPN) Double door Cat N0- DHDLVDRWGOFO08 MakeHavells or equivalent out of makes specified in list of makes.
80S&F in replacement MCB 240 volts SPN 06- 32 amp10KA breaking, capacity, ISI marked,complete all as specified and directed. Cat No- DHMCCSNF006-032 Make Havells or equivalent out of makes specified in list of make.
81S&F in replacement MCB 240 volts 2 pole (DP) - 40 amp10KA breaking, capacity, ISI marked,complete all as specified and directed. Cat No- DHMCCSNF006-032 Make Havells or equivalent out of makes specified in list of make.
82S&F in replacement MCB 240 volts SP 6- 32 amp10KA breaking, capacity, ISI marked, complete all as specified and directed. Cat No- DHMCCSPF006-032 Make Havells or equivalent
83S&F in replacement MCB 415volts TPN 63 amp10KA breaking, capacity, ISI marked, complete all as specified and directed, Cat No- DHMCCTNF063 of Make Havells or equivalent out of makes specified in list of make.
84Supply & Fix in replacement of MCCB 4 pole 415 V fixed type 63 Amps with breaking capacity 16 KA complete all as specified and directed
85S&F in replacement MCCB 100 Amps 4 pole 415 Volts10 KA breaking capacity complete all as specified and directed, Cat No- 0270 39 of Make Legrand or equivalent out of makes specified in list of make.
86S&F in replacement Blanking plates suitable for MCB DB"s of Make Havells or equivalent out of makes specified in list of make.
87Supply and fixing in replacement industrial panel mounting Socket Splash proof 16 amp protection degree 44 , code DHQCA65016 of Havells PIN 3P+N+E or equivalent out of makes specified in list of make
88Supply and fixing in replacement industrial panel mounting Plug Splash proof 16 amp protection degree 44 , code DHQBA65016 of Havells PIN 3P+N+E or equivalent out of makes specified in list of make
89S&F in replacement in replacement false ceiling light fittings with new energy saving LED ceiling lightfitting of capacity 34 /36 Wattof size 600X600mm including 3 core PVC insulated copper conductor upto ceiling rose and testing complete all as directed by Engr-in-charge. Make : Havells cat part No :- DROPDOWNFLAT2X2PLR34WLED840S or equivalent out of makes specified in list of makes.
90S & F in replacementLEDsurfase light square 16 watt size 1"x1" with cover complete all as directed by Engr-in-charge. Make crompton/havells/Evereadyor equivalent out of makes specified in list of makes.
91Supply and fixing in replacement LEDsurfase light square 22 watt size 225 X225 X 40(H) with cover complete all as directed by Engr-in-charge. Make crompton/havells/Eveready or equivalent out of makes specified in list of makes.
92Supply and fixing in replacementnew energy saving LEDT 8Tubelight Fitting 4 feet clear cool white 20 Wattwith inbuilt LED Driver complete all as directed by Engr-in-charge. Make crompton/havells/Eveready or equivalent out of makes specified in list of makes.
93Supply only Self ballasted Led Retrofit Bulbs with PBT Body shell and PC diffuser LED LAMP 7 Watt BC 6500 K Make - Crompton /eveready/Havells
94Supply only in replacement of indoor decorative LED batten light fitting 1x9/10W tube light fitting with 2 feet long LED Tube of 9/10W complete with all accessories internally prewired complete all as specified and directed by Engineer-in-Charge. Make:- Eveready/ crompton/rhino
95Supply only Self ballasted Led Retrofit Bulbs with PBT Body shell and PC diffuser LED LAMP 14 Watt BC 6500 K Make - Cromption / phillips/rhino/eveready
96S&F in replacement of Gang box for 15 Amps socket complete including 15 Amps switch socket combination complete all as specified and directed by Engineer-in-Charge.
97S&F in replacement of Gang box for 5 Amps socket complete including 5 Amps switch socket combination complete all as specified and directed by Engineer-in-Charge.
98M&L for checking of Energy Meters single/three phase 2/4 wire of any Make /type including testing , checking and reporting any tempering and intimate meter reading at time of electric meter testing & re-sealing all as specified and directed. (NOTE: Necessary transportation upto building testing and checking arrangements with equipment and metre calibration certificate will be provided by contactor)
99M&L for taking down unserviceable energy meter 1 phase from meter box after disconnecting all incoming and outgoing connection complete all as specified and as directed by Engr-in-charge.
100M&L fortaking down unserviceable energy meter 3 phase from meter box after disconnecting all incoming and outgoing connectioncomplete all as specified and as directed by Engr-in-charge.
101S&F in replacement single phase electronic energy meter 10-40A in poly carbonate body with LCD display in class 1.0 only kwh in meter box including making necessary electrical (incoming and outgoing) connectioncomplete all as specified and as directed by Engr-in-charge. Make HPL/ L&T/Secure.
102S&F in replacement three phase electronic energy meter 10-60A in poly carbonate body with LCD display in class 1.0 only kwh in meter box including making necessary electrical (incoming and outgoing) connectioncomplete all as specified and as directed by Engr-in-charge. Make HPL/ L&T/Bentex.
103S & F in repalacement service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed of size 6 Sqmm, 2 core complete all as specified and directed by Engr-in-Charge.
104S & F in repalacement service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed of size 10 Sqmm, 2 core complete all as specified and directed by Engr-in-Charge.
105S & F in replacement of Exhaust fan iron body type 300-350mm Sweep including making necessary well finished hole for fixing complete all as directed by Engg-in-charge. Make Crompton/Bajaj/Havells or equivalent out of makes specified in list of makes.
106S & F in replacement of Exhaust fan PVC body type 300-350mm Sweep including making necessary well finished hole for fixing complete all as specified and directed. Make Crompton/Bajaj/Havells or equivalent out of makes specified in list of makes.
107S & F in replacement of ceiling fan 1200mm BLDC complete all as specified and directed. Make Crompton/Bajaj/Havells or equivalent out of makes specified in list of makes.
108S& F in replacement of 15 Amp plug top complete as specified and as directed Make: Anchor/Havells or equivalent out of makes specified in list of makes.
109Note:- The amount of Rs 2,57,120/- against Schedule of Credit on Page No 117 shall be deducted from the total amount quoted against Sch "A"while deriving the Contract Sum for Acceptance