Repair Maintenance Of Electrical And Mechanical Services At Trade , Taxes, Vyapar Bhawan Building, I.P. Estate New Delhi. Providing / Replacement Of Outlived Electrical Accessories And Equipments- Wiring For Light Point / Fan Point / Exhaust F, delhi-Delhi

Public Works Department-PWD has published Repair Maintenance Of Electrical And Mechanical Services At Trade , Taxes, Vyapar Bhawan Building, I.P. Estate New Delhi. Providing / Replacement Of Outlived Electrical Accessories And Equipments- Wiring For Light Point / Fan Point / Exhaust F. Submission Date for this Tender is 12-05-2022. Electromechanical Services Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

32083258
Repair Maintenance Of Electrical And Mechanical Services At Trade , Taxes, Vyapar Bhawan Building, I.P. Estate New Delhi. Providing / Replacement Of Outlived Electrical Accessories And Equipments- Wiring For Light Point / Fan Point / Exhaust F
Open Tender
Indian
Delhi
delhi
12-05-2022

Tender Details

Repair Maintenance Of Electrical And Mechanical Services At Trade , Taxes, Vyapar Bhawan Building, I.P. Estate New Delhi. Providing / Replacement Of Outlived Electrical Accessories And Equipments- Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Pointwith 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Corecable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etcas Required. A ) Group C 2 Supplying And Fixing Of Pvc Cable Management System / Wall Trunking With Cover Of Following Sizes Including Internal, External , Flat Single Cover And T- Cover , End Cap And Other Accessories On The Wall So As To Make Complete As Reqd. A ) 105 Mm X 50Mm 3 B ) 50 Mm X 50Mm 4 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel Conduit As Required.A ) 3 X 1.5 Sq.Mm 5 B ) 3 X 4 Sq.Mm 6 C ) 3 X 6 Sq.Mm 7 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Requireda ) 20 Mm 8 Supplying, Installation, Testing & Commissioning Of Following Capacity Energy Saving Ip-66 Led Flood Light Fitting On Angle Iron Frame Suitable To Work 230 Volt Ac Supply Complete With Connection Etc. With 1.5 Sq.Mm Pvc Insulated Copper Conductor Wire As Reqd At Site. A ) 150 Watt Flood Light 9 Supplying, Installation, Testing And Commissioning Of Stainless Steel Storage Type Water Cooler 150 / 150 Ltr. Capacity Fully Stain Less Steel Suitable For Operation On 230 V + 10% 50 Hz Single Phase Ac Supply I / C Making Water Line And Electrical Connection Etc As Reqd. ( Blue Star / Voltas / Usha Make ) 10 Supplying & Fixing Of 2 Mm Thick Galvanized Iron Raceway Of Size 150 Mmx 38 Mm With Single Partitionall Gi Nut Boltsi / C Bends & Elbows Direct In Ground By Chasing The Ground Level Upto 250 Mm Deep And Making The Surface Same With Sand Cushinioning Etc Complete As Reqd. 11 Supplying & Fixing Of 2 Mm Thick Galvanized Iron Raceway Of Size 50 Mmx 38 Mm With Single Partitionall Gi Nut Boltsi / C Bends & Elbows Direct In Ground By Chasing The Ground Level Upto 250 Mm Deep And Making The Surface Same With Sand Cushinioning Etc Complete As Reqd. 12 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection Etc. As Required. 13 Supply, Installation, Testing Andcommissioning Of 1200Mm Sweep, Bee 5 Star Rated, Ceiling Fan Wih Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cmm / W ) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nutbolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230V, 50 Hz, Single Phase Ac Supply, Earthing Etc Complete As Required. 14 Supplying, Installation, Testing & Commissioning Of 400Mm Steel Sweep Size Oscillating Type Wall Fan With Fan Regulator And Fixing With The Help Of Dash Fasteners Including Connections Etc As Required. 15 Supplying, Installation, Testing & Commissioning Of 6000K ( 1200 Mm ) Energy Efficient Led Wall Mounted Light Luminaries, Extruded Aluminum Heat Sink Provided For Efficient Heat Dissipation & Integrated Electronic Driver, Suitable To Work On 230 Volts, Ac Supply Complete With Connection Etc. With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required At Site The Luminaries Shall Be Submitted With Lm-80 Report With A Life Of 50000 Hours @ L-70 And Led Photo Biological Safety Report Conforming To Iec 62471 & Led Source Manufacturer And Lm-79 Report From Nabl Accredited Lab. The Led Chip Should Be Of Cree, Nichia, Philips Lumiled, Osram. 16 Supplying, Installation, Testing & Commissioning Of Energy Efficient 2 Tr Capacity Split Inverter Type Air Conditioner Unit ( Minimum 3 Star Bee Rating ) Having Copper Condenser Coil Suitable For Operation On 230 Volts, 50Hz, Single Phase Capable Of Performing Cooling, Dehumidifying, Air Circulating & Filtering Complete Connection With Upto 4 Meters Length Refrigerant Copper Pipe Heavy Gauge 2 / 8 / 3 / 8 & 5 / 8 Covered With Minimum 10Mm Thickness Insulation Including 3 X 2.5 Sq.Mm Flexible Copper Conductor Wire Wrapped In Flexible Pipe And Also Providing 25Mm Diameter Pvc Drain Connection Including Accessories, Fixing On Surface With Clamp To The Nearest Drain Connection Pipe Complete With Repairing Of Wall With Minor Civil Work At Site Etc As Required. 17 Supplying, Installation, Testing & Commissioning Of Energy Efficient 1.5 Tr Capacity Split Inverter Type Air Conditioner Unit ( Minimum 3 Star Bee Rating ) Having Copper Condenser Coil Suitable For Operation On 230 Volts, 50Hz, Single Phase Capable Of Performing Cooling, Dehumidifying, Air Circulating & Filtering Complete Connection With Upto 4 Meters Length Refrigerant Copper Pipe Heavy Gauge 2 / 8 / 3 / 8 & 5 / 8 Covered With Minimum 10Mm Thickness Insulation Including 3 X 2.5 Sq.Mm Flexible Copper Conductor Wire Wrapped In Flexible Pipe And Also Providing 25Mm Diameter Pvc Drain Connection Including Accessories, Fixing On Surface With Clamp To The Nearest Drain Connection Pipe Complete With Repairing Of Wall With Minor Civil Work At Site Etc As Required. 18 Supplying, Installation, Testing And Commissioning Of Energy Efficient Cassette Type Air Conditioner Unit Of Minimum 2 Tr Capacity, 6000 K Cal / Hour Capacity Complete With Outdoor Condensing Unit & Ceiling Mounted Evaporating Unit Having Cordless Remote Control With Angle Iron Rod, Clamp & Fastner Type Hook For Supporting Of Indoor Unit, Capable Of Cooling, Filtering & Dehumidifying, Suitable For Operation On 230Volts, Single Phase, Ac Supply Complete With Copper Refrigeration Pipe Up To 4 Meters Length And Suitable Length Of Drain Pipe With Outdoor Unit Stand Etc. As Required 19 Supplying, Installation, Testing & Commissioning Of Surface Type 15 W To 18 Wfull Window Glarefree Opal Diffuser Led Fitting Of Size 300 Mm X 300 Mm Complete With All Accessories I / C Connections With 3 X 1.5 Sq.Mm Pvc Insulated Frls Copper Conductor Cable Etc. As Reqd. 20 Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A, Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Requireda ) 8 Way ( 4 + 24 ) , Double Door 21 Supplying And Fixing Cable End Box ( Loose Wire Box ) ( Ip 43 ) Suitable For Following Triple Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Testing And Commissioning Etc. As Required 22 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.A ) Single Pole 23 Sitc Of Energy Efficient Recess Mounted Type 34W To 38W Full Window Glare Free Opal Diffuser Led Panel Luminaries Of Size 595Mm X 595Mm ( Nominal Size ) Suitable For Both Armstrong / Pop / Geypsum Board Or Grid False Ceiling Fabricated With Ms Powder Coated White Crca Housing Including Mounting With The Help Of Chain / Other Suitable Method, Hanging From The Ceiling Including Connections With 3 X 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. The Total System Lumen Of 34W To 38W Led Should Be 3600 With Minimum System Efficacy Of 100 Lumen / Watt Colour Temperature 5500K To 6500K, Power Factor>0.95, Cri ( Ra ) >75, Thd <10%, With Apfc Driver Having Driver Efficiency >85%, Operating Voltage 150-270 Volts With Minimum 2.5Kv Surge Protection. The Luminaries Shall Be Submitted With Lm-80 Report With A Life Of 50000 Hours @ L-70 And Led Photo Biological Safety Report Conforming To Iec 62471 & Led Source Manufacturer And Lm-79 Report From Nabl Accredited Lab. 24 Sitc Of Energy Efficient Surface Mounted Type 34W To 38W Full Window Glare Free Opal Diffuser Led Panel Luminaries Of Size 595Mm X 595Mm ( Nominal Size ) Suitable For Both Armstrong / Pop / Geypsum Board Or Grid False Ceiling Fabricated With Ms Powder Coated White Crca Housing Including Mounting With The Help Of Chain / Other Suitable Method, Hanging From The Ceiling Including Connections With 3 X 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. The Total System Lumen Of 34W To 38W Led Should Be 3600 With Minimum System Efficacy Of 100 Lumen / Watt Colour Temperature 5500K To 6500K, Power Factor>0.95, Cri ( Ra ) >75, Thd <10%, With Apfc Driver Having Driver Efficiency >85%, Operating Voltage 150-270 Volts With Minimum 2.5Kv Surge Protection. The Luminaries Shall Be Submitted With Lm-80 Report With A Life Of 50000 Hours @ L-70 And Led Photo Biological Safety Report Conforming To Iec 62471 & Led Source Manufacturer And Lm-79 Report From Nabl Accredited Lab. 25 Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb In Existing Tpn Db Including, Making Connections, Etc. As Required.A ) 100 Amp, 16 Ka, Tpmccb With Thermal Megnatic Release ( Icu= 100% Ics ) 26 Suppying And Layingof One Number Pvc Insulated And Al. Conductor Armored Power Cable Of 1.1 Kv Grade Of Following Size Direct On Surface / Wall As Required. A ) 4 X 25 Sq.Mm 27 B ) 3.5 X 35 Sq.Mm 28 C ) 3 X 10 Sq. Mm 29 Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. ( A ) 3.5 X 35 Sq.Mm ( 35Mm ) 30 ( B ) 4X25 Sq Mm ( 28 Mm ) 31 ( C ) 3 X 10 Sq. Mm ( 22Mm ) 32 Sitc Of Exhaust Fan Of 300 Mm Sweep, 900 Rpm Speed With Shutter & Louvers In The Existing Opening I / C , Making Good The Damages, Connection, Testing & Commissioning Etc. As Reqd. 33 Supplying, Installation, Testing & Commissioning Of Surface Type 15 Wdown Lighter Glarefree Opal Diffuser Led Fittingcomplete With All Accessories I / C Connections With 3 X 1.5 Sq.Mm Pvc Insulated Frls Copper Conductor Cable Etc. As Reqd. 34 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc. As Required. ( A ) 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Meter 35 ( B ) 375 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Meter 36 Supplying And Replacement Of Following Capacity Smf Batteries 12 Volts With Battery Connecting Cables, Bolted Terminal, Low Self Discharge, Excellent Charge Retention And Recovering Ability, 24 Monthes Warranty Including Connection With Suitable Lead As Per Engineer-In-Charge Including Credit Of Old Dismantle Material Under Buy Back Etc As Required. ( A ) 200 Ah For Ups 37 ( B ) 180 Ah For Dg Sets 38 Credit For Following Items A ) Assorted Luminaries 39 B ) Wire Pvc Insulated Assorted 40 C ) Assorted Ceiling Fans / Exhaust Fans 41 D ) Assorted Tpndb With Spmcb 42 E ) Wall Fan 43 F ) Cables 44 G ) 1.5 Ton Split Ac 45 H ) 2 Ton Split Ac 46 I ) 2 Ton Cassette Ac 47 J ) Water Cooler 150 Litres

Key Value

Document Fees
Refer document
EMD
INR 127822.0 /-
Tender Value
INR 63.91 Lakhs /-

BOQ Items

Name of Work: RMO Electrical and Mechanical Services at Trade & Taxes, Vyapar Bhawan Building, I.P. Estate New Delhi. (SH: Providing/ Replacement of outlived electrical accessories and equipments).
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell pointwith 1.5 sq.mm FRLS PVC insulated copper conductor single corecable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etcas required. a) Group C
2Supplying and fixing of PVC cable management system /wall trunking with cover of following sizes including internal, external , flat single cover and T- cover , end cap and other accessories on the wall so as to make complete as reqd. a) 105 mm X 50mm
3b) 50 mm X 50mm
4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel conduit as required. a) 3 x 1.5 Sq.mm
5b) 3 x 4 Sq.mm
6c) 3 x 6 Sq.mm
7Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required a) 20 mm
8Supplying, installation, testing & commissioning of following capacity energy saving IP-66 LED flood light fitting on angle iron frame suitable to work 230 volt AC supply complete with connection etc. with 1.5 sq.mm PVC insulated copper conductor wire as reqd at site. a)150 watt Flood light
9Supplying, Installation, Testing and commissioning of stainless steel storage type water cooler 150/150 ltr. Capacity fully stain less steel suitable for operation on 230 V + 10% 50 Hz single phase AC supply i/c making water line and electrical connection etc as reqd. (Blue star/ Voltas/ Usha make)
10Supplying & Fixing of 2 mm thick Galvanized Iron Raceway of size 150 mmX 38 mm with Single partitionall GI nut boltsi/c bends & elbows direct in ground by chasing the ground level upto 250 mm deep and making the surface same with sand cushinioning etc complete as reqd.
11Supplying & Fixing of 2 mm thick Galvanized Iron Raceway of size 50 mmX 38 mm with Single partitionall GI nut boltsi/c bends & elbows direct in ground by chasing the ground level upto 250 mm deep and making the surface same with sand cushinioning etc complete as reqd.
12Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
13Supply, Installation, Testing andCommissioning of 1200mm sweep, BEE 5 star rated, ceiling fan wih Brush Less Direct current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85,Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nutbolts, washers, temperature rise=75 degree C (max.),insulation resistance more than 2 mega ohm, suitable for 230V, 50 Hz, single phase AC Supply, earthing etc complete as required.
14Supplying, installation, testing & commissioning of 400mm steel sweep size Oscillating type wall fan with fan regulator and fixing with the help of dash fasteners including connections etc as required.
15Supplying, installation, testing & commissioning of 6000K (1200 mm) energy efficient LED wall mounted light luminaries, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver, suitable to work on 230 volts, AC supply complete with connection etc. with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required at site The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram.
16Supplying, installation, testing & commissioning of energy efficient 2 TR capacity Split inverter type Air Conditioner unit(Minimum 3 star BEE Rating) having copper condenser coil suitable for operation on 230 Volts, 50Hz, single phase capable of performing Cooling, Dehumidifying, Air Circulating & Filtering complete connection with upto 4 meters length refrigerant copper pipe heavy gauge 2"/8" / 3"/8" & 5/8" covered with minimum 10mm thickness insulation including 3 x 2.5 sq.mm flexible copper conductor wire wrapped in flexible pipe and also providing 25mm diameter PVC drain connection including accessories, fixing on surface with clamp to the nearest drain connection pipe complete with repairing of wall with minor civil work at site etc as required.
17Supplying, installation, testing & commissioning of energy efficient 1.5 TR capacity Split inverter type Air Conditioner unit(Minimum 3 star BEE Rating) having copper condenser coil suitable for operation on 230 Volts, 50Hz, single phase capable of performing Cooling, Dehumidifying, Air Circulating & Filtering complete connection with upto 4 meters length refrigerant copper pipe heavy gauge 2"/8" / 3"/8" & 5/8" covered with minimum 10mm thickness insulation including 3 x 2.5 sq.mm flexible copper conductor wire wrapped in flexible pipe and also providing 25mm diameter PVC drain connection including accessories, fixing on surface with clamp to the nearest drain connection pipe complete with repairing of wall with minor civil work at site etc as required.
18Supplying, Installation, Testing and Commissioning of energy efficient cassette type Air Conditioner unit of minimum 2 TR capacity, 6000 k cal/hour capacity complete with outdoor condensing unit & ceiling mounted evaporating unit having cordless remote control with angle iron rod, clamp & fastner type hook for supporting of indoor unit, capable of cooling, filtering & dehumidifying, suitable for operation on 230Volts, single phase, AC supply complete with copper refrigeration pipe up to 4 meters length and suitable length of drain pipe with outdoor unit stand etc. as required
19Supplying, installation, testing & commissioning of surface type 15 W to 18 Wfull window glarefree opal diffuser LED fitting of size 300 mm x 300 mm complete with all accessories i/c connections with 3 x 1.5 sq.mm PVC insulated FRLS copper conductor cable etc. as reqd.
20Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required a) 8 way (4 + 24), Double door
21Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required
22Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) Single pole
23SITC of energy efficient recess mounted type 34W to 38W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size) suitable for both Armstrong/POP/Geypsum Board or grid false ceiling fabricated with MS powder coated white CRCA housing including mounting with the help of chain/other suitable method, hanging from the ceiling including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. The Total system Lumen of 34W to 38W LED should be 3600 with minimum system efficacy of 100 lumen /watt colour temperature 5500K to 6500K, power factor>0.95,CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab.
24SITC of energy efficient surface mounted type 34W to 38W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size) suitable for both Armstrong/POP/Geypsum Board or grid false ceiling fabricated with MS powder coated white CRCA housing including mounting with the help of chain/other suitable method, hanging from the ceiling including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. The Total system Lumen of 34W to 38W LED should be 3600 with minimum system efficacy of 100 lumen /watt colour temperature 5500K to 6500K, power factor>0.95,CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab.
25Providing and fixing following rating and breaking capacity and pole MCCB in existing TPN DB including, making connections, etc. as required. a) 100 Amp, 16 KA,TPMCCB with thermal megnatic release(ICU= 100% ICS)
26Suppying and layingof one number PVC insulated and Al. Conductor armored power cable of 1.1 KV grade of following size direct on surface /wall as required. a) 4 X 25 Sq.mm
27b) 3.5 X 35 Sq.mm
28c) 3 X 10 sq. Mm
29Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. (a) 3.5 X 35 Sq.mm (35mm)
30(b) 4x25 sq mm(28 mm)
31(c) 3 X 10 sq. mm (22mm)
32SITC of exhaust fan of 300 mm sweep, 900 rpm speed with shutter & louvers in the existing opening i/c , making good the damages, connection, testing & commissioning etc. as reqd.
33Supplying, installation, testing & commissioning of surface type 15 Wdown lighter glarefree opal diffuser LED fittingcomplete with all accessories i/c connections with 3 x 1.5 sq.mm PVC insulated FRLS copper conductor cable etc. as reqd.
34Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (a) 300 mm width X 50 mm depth X 1.6 mm thickness meter
35(b) 375 mm width X 50 mm depth X 1.6 mm thickness meter
36Supplying and Replacement of following capacity SMF Batteries 12 volts with battery connecting cables, bolted terminal, Low self discharge, Excellent charge retention and recovering ability, 24 monthes warranty including connection with suitable lead as per Engineer-in-Charge including credit of old dismantle material under buy back etc as required. (a) 200 AH for UPS
37(b) 180 AH for DG sets
38Credit for following items a) assorted luminaries
39b) Wire PVC Insulated Assorted
40c) Assorted ceiling fans/Exhaust Fans
41d) Assorted TPNDB with SPMCB
42e) Wall fan
43f) Cables
44g) 1.5 ton split ac
45h) 2 ton split ac
46i) 2 ton cassette ac
47j) water cooler 150 litres