Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 0 days TDR #32063639

Electrical Wiring Works For Providing Ups Power Points To Desktops Electrical Wiring Works For Providing Ups Power Points To Desktops At Cpcl Corporate Office, Chennai , Supplying And Fixing Of 6 - Way Three Pole And Neutral Sheet Steel Mcb Distribution

Issued by Boards / Undertakings / PSU · Chennai, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 May 2022
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Electrical Wiring Works For Providing Ups Power Points To Desktops Electrical Wiring Works For Providing Ups Power Points To Desktops At Cpcl Corporate Office, Chennai , Supplying And Fixing Of 6 - Way Three Pole And Neutral Sheet Steel Mcb Distribution Board, 240 Volts, On Surface / Recess Complete With Tinned Copper Busbar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Inter Connections Including Painting, Earthing, Etc. As Required ( With Ip 42 Protection - Accrylic Door ) . , Supply And Fixing Of Metal Box Of 200 Mm X 150 Mm X 100 Mm Deep On Surface With Suitable Size Of Phenolic Laminated Sheet Cover In The Front Including Painting, Etc. As Required. , Supplying And Fixing Of 5-32 A Rating 240 Volts, 50Hz, 10Ka, B Curve, Miniature Circuit Breacker ( Suitable For Lighting And Other Domestic Loads And Conforming To Is 8828: 19 ) Of Single Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning, Etc. As Required. Note: Isi Marked Mcbs Of Havells / Loadster / Indo Kopp / Equivalent Make Shall Be Used As Per Direction Of Engineer-In-Charge. , Supplying And Fixing 40 Amps. Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning, Etc. As Required. Note: Isi Marked Isolators Shall Be Used. , Supplying And Drawing Following Size Of Frls Pvc Insulated, Copper Conductor, Single Core Cable In The Existing Surface / Recessed, Pvc / Steel Conduit / Pvc Casing And Capping As Required. Note: Only Isi Marked Cables Shall Be Used. , 1 X 1.5 Sq.Mm , 2 X 2.5 Sq.Mm , 2 X 4 Sq.Mm , Supply And Fixing Of 25 Mm Pvc Conduit Alongwith The Accessories In Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed, Conduit As Required: Note: Only Isi Marked Conduits Shall Be Used. , Providing And Fixing 50 Mm X 20 Mm Pvc Casing And Caping On Surface As Required. Note: Only Isi Marked Caping And Casing Shall Be Used. , Providing And Fixing 25 Mm X 10 Mm Pvc Casing And Caping On Surface As Required. Note: Only Isi Marked Caping And Casing Shall Be Used. , Supply And Fixing Of 6 Module Plastic / Metal Surface Boxes To Accommodate Mosaic Wiring Accessories Of M / S Mds Or Approved Equivalent Including Supply And Fixing Of Nuts, Bolts, Etc. Complete With Labour And Materials As Per Direction Of The Engineer-In-Charge. , Supply And Fixing Of 6 Module White Cover Plate With Frame For Mosaic Wiring Accessories Of M / S Mds Or Approved Equivalent Including Supply And Fixing Of Nuts, Bolts, Etc. Complete With Labour And Materials As Per Direction Of The Engineer-In-Charge. , Supply, Fixing And Connection Of Modular Type Of Anchor Make ( Roma ) Or Approved Equivalent Switch, Socket Bell Push, Etc. In Havells / Siemens / Anchor / L&T, Complete With Labour And Materials As Per Direction Of The Engineer-In-Charge. , 10 A, 1Way Switch , 3 Pins 10 / 20A, Heavy Duty Uni Socket Outlet With Isi Mark , Dismantling Of Tube Light Fittings Of All Types / Makes Including Single / Double Tube Light Fittings And Bulk Head Fittings Installed At Different Places In Free Zones Without Damage And Returning Them To Our Stores Or Any Other Place Or Site Within The Premises As Decided By The Engineer-In-Charge, All Complete With Labour And Materials Including Dismantling Of Supports Of Any Type, Down Rods, Chokes, Condensers And Any Other Accessories As Per The Directions Of The Engineer-In-Charge. , Fixing Of Recessed Tubelight Fitting On Ms Hanger / Supports / Concrete Wall Structure / Steel Structure Completed With Lead In Wires And Other Accessories All Complete With Labour And Materials As Per Direction Of The Engineer-In-Charge. ( Cost Of Light Fittings / Lamp Control Gears And Other Fittings Shall Be Excluded ) . , The Scope Of Work Includes Stencilling Of Letter / Number Of Size Up To 2 On Panels, Cable Drums, Etc., As Per The Directions Of Engineer-In-Charge And System - Viii Of Cpcl, Including Labour And Materials. , Supply Of 4C *6 Sqmm Pvc Insulated And Fr Pvc Round Sheathed, Copper Conductor ( Flexible ) Industrial Cable, 1100 Volt, Conforming To Is 694 => Limited

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-May-2022 Corrigendum No.1 Date 16-May-2022

BOQ

Name of Work: Electrical Wiring Works for providing UPS Power Points to Desktops at CPCL Corporate Office, Chennai
Sl. No. Item Description
1Supplying and fixing of 6 - Way three pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess complete with tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, inter connections including painting, earthing, etc. as required (with IP 42 protection - accrylic door).
2Supply and fixing of metal box of 200 mm x 150 mm x 100 mm deep on surface with suitable size of phenolic laminated sheet cover in the front including painting, etc. as required.
3Supplying and fixing of 5-32 A rating 240 volts, 50Hz, 10KA, \"B\" Curve, miniature circuit breacker (suitable for lighting and other domestic loads and conforming to IS 8828: 19) of single poles in the existing MCB DB complete with connections, testing and commissioning, etc. as required.Note: ISI marked MCBs of Havells / Loadster / Indo Kopp/equivalent make shall be used as per direction of Engineer-in-Charge.
4Supplying and fixing 40 amps. Four Pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning, etc. as required.Note: ISI marked isolators shall be used.
5Supplying and drawing following size of FRLS PVC insulated, copper conductor, single core cable in the existing surface / recessed, PVC / steel conduit / PVC casing and capping as required.Note: Only ISI marked cables shall be used.
61 X 1.5 sq.mm
72 X 2.5 sq.mm
82 X 4 sq.mm
9Supply and fixing of 25 mm PVC conduit alongwith the accessories in recess including cutting the wall and making good the same in case of recessed, conduit as required:Note: Only ISI marked conduits shall be used.
10Providing and fixing 50 mm x 20 mm PVC casing and caping on surface as required.Note: Only ISI marked caping and casing shall be used.
11Providing and fixing 25 mm x 10 mm PVC casing and caping on surface as required.Note: Only ISI marked caping and casing shall be used.
12Supply and fixing of 6 module Plastic / metal surface boxes to accommodate mosaic wiring accessories of M/s MDS or approved equivalent including supply and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.
13Supply and fixing of 6 module white cover plate with frame for mosaic wiring accessories of M/s MDS or approved equivalent including supply and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.
14Supply, fixing and connection of modular type of Anchor make (Roma) or approved equivalent switch, socket bell push, etc. in Havells/Siemens/Anchor/L&T, complete with labour and materials as per direction of the Engineer-in-Charge.
1510 A, 1way switch
163 pins 10/20A, heavy duty uni socket outlet with ISI mark
17Dismantling of Tube light fittings of all types/makes including single/double tube light fittings and bulk head fittings installed at different places in free zones without damage and returning them to our stores or any other place or site within the premises as decided by the Engineer-in-Charge, all complete with labour and materials including dismantling of supports of any type, down rods, chokes, condensers and any other accessories as per the directions of the Engineer-in-Charge.
18Fixing of RECESSED TUBELIGHT FITTING on MS hanger / supports / concrete wall structure / steel structure completed with lead in wires and other accessories all complete with labour and materials as per direction of the Engineer-in-Charge. (cost of light fittings/lamp control gears and other fittings shall be excluded).
19The scope of work includes stencilling of Letter / Number of size up to 2\" on panels, cable drums, etc., as per the directions of Engineer-in-Charge and System - VIII of CPCL, including labour and materials.
20Supply of 4C *6 sqmm PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694

AI Tender Summary

OUR REF NO 32063639
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 16-05-2022
Authority
Authority Name Chennai Petroleum Corporation Limited
Work Description Electrical Wiring Works For Providing Ups Power Points To Desktops Electrical Wiring Works For Providing Ups Power Points To Desktops At Cpcl Corporate Office, Chennai , Supplying And Fixing Of 6 - Way Three Pole And Neutral Sheet Steel Mcb Distribution Board, 240 Volts, On Surface / Recess Complete With Tinned Copper Busbar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Inter Connections Including Painting, Earthing, Etc. As Required ( With Ip 42 Protection - Accrylic Door ) . , Supply And Fixing Of Metal Box Of 200 Mm X 150 Mm X 100 Mm Deep On Surface With Suitable Size Of Phenolic Laminated Sheet Cover In The Front Including Painting, Etc. As Required. , Supplying And Fixing Of 5-32 A Rating 240 Volts, 50Hz, 10Ka, B Curve, Miniature Circuit Breacker ( Suitable For Lighting And Other Domestic Loads And Conforming To Is 8828: 19 ) Of Single Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning, Etc. As Required. Note: Isi Marked Mcbs Of Havells / Loadster / Indo Kopp / Equivalent Make Shall Be Used As Per Direction Of Engineer-In-Charge. , Supplying And Fixing 40 Amps. Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning, Etc. As Required. Note: Isi Marked Isolators Shall Be Used. , Supplying And Drawing Following Size Of Frls Pvc Insulated, Copper Conductor, Single Core Cable In The Existing Surface / Recessed, Pvc / Steel Conduit / Pvc Casing And Capping As Required. Note: Only Isi Marked Cables Shall Be Used. , 1 X 1.5 Sq.Mm , 2 X 2.5 Sq.Mm , 2 X 4 Sq.Mm , Supply And Fixing Of 25 Mm Pvc Conduit Alongwith The Accessories In Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed, Conduit As Required: Note: Only Isi Marked Conduits Shall Be Used. , Providing And Fixing 50 Mm X 20 Mm Pvc Casing And Caping On Surface As Required. Note: Only Isi Marked Caping And Casing Shall Be Used. , Providing And Fixing 25 Mm X 10 Mm Pvc Casing And Caping On Surface As Required. Note: Only Isi Marked Caping And Casing Shall Be Used. , Supply And Fixing Of 6 Module Plastic / Metal Surface Boxes To Accommodate Mosaic Wiring Accessories Of M / S Mds Or Approved Equivalent Including Supply And Fixing Of Nuts, Bolts, Etc. Complete With Labour And Materials As Per Direction Of The Engineer-In-Charge. , Supply And Fixing Of 6 Module White Cover Plate With Frame For Mosaic Wiring Accessories Of M / S Mds Or Approved Equivalent Including Supply And Fixing Of Nuts, Bolts, Etc. Complete With Labour And Materials As Per Direction Of The Engineer-In-Charge. , Supply, Fixing And Connection Of Modular Type Of Anchor Make ( Roma ) Or Approved Equivalent Switch, Socket Bell Push, Etc. In Havells / Siemens / Anchor / L&T, Complete With Labour And Materials As Per Direction Of The Engineer-In-Charge. , 10 A, 1Way Switch , 3 Pins 10 / 20A, Heavy Duty Uni Socket Outlet With Isi Mark , Dismantling Of Tube Light Fittings Of All Types / Makes Including Single / Double Tube Light Fittings And Bulk Head Fittings Installed At Different Places In Free Zones Without Damage And Returning Them To Our Stores Or Any Other Place Or Site Within The Premises As Decided By The Engineer-In-Charge, All Complete With Labour And Materials Including Dismantling Of Supports Of Any Type, Down Rods, Chokes, Condensers And Any Other Accessories As Per The Directions Of The Engineer-In-Charge. , Fixing Of Recessed Tubelight Fitting On Ms Hanger / Supports / Concrete Wall Structure / Steel Structure Completed With Lead In Wires And Other Accessories All Complete With Labour And Materials As Per Direction Of The Engineer-In-Charge. ( Cost Of Light Fittings / Lamp Control Gears And Other Fittings Shall Be Excluded ) . , The Scope Of Work Includes Stencilling Of Letter / Number Of Size Up To 2 On Panels, Cable Drums, Etc., As Per The Directions Of Engineer-In-Charge And System - Viii Of Cpcl, Including Labour And Materials. , Supply Of 4C *6 Sqmm Pvc Insulated And Fr Pvc Round Sheathed, Copper Conductor ( Flexible ) Industrial Cable, 1100 Volt, Conforming To Is 694 => Limited
Basic Detail
Tender No CPCL CBRP 0822
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 09 May 2022
Submission Date 16 May 2022
Open Date 16 May 2022
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
6781ce56-0bd5-456b-907f-25f05d86dd9d.html
BOQ_8805.xls
General_Conditions_of_Con.pdf
Tendernotice_1.pdf
Tender_Document_Electrica.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 09, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
May 16, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 16, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 16, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

6781ce56-0bd5-456b-907f-25f05d86dd9d.html

xls

BOQ_8805.xls

pdf

General_Conditions_of_Con.pdf

pdf

Tendernotice_1.pdf

pdf

Tender_Document_Electrica.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders