Military Engineer Services-MES has published Cleaning Of Overhead Tank, Ug Sump Other Misc Work At Different Pump Houses Including Repair / Replacement Of Automation System In The Area Of Age E / M Ext ( Ws ) Under Ge ( E / M ) Lucknow. Submission Date for this Tender is 26-05-2022. Industrial Cleaning Work Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 12-May-2022 | Corrigendum1 | Financial Bid | 19-05-2022 |
2 | 12-May-2022 | Corrigendum1 | BOQ | 19-05-2022 |
3 | 19-May-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-05-2022 |
Sl. No. | Item Description |
1 | Wash out complete water by pumping set/manually of existing Underground sump/ static water tank up to50000 gallons capacity including removing deposited sand from inside the tank, scrubbing and washing side walls and bottom with bleaching powder solution and making surface free from any fungus deposits stains using wire brush, filling of cavaties inside of tank with CM 1:1 with quick setting cement and applying two coat of white wash inside & writing date of cleaning complete all as specified and directed. Note:-1. All type of T & P, Labour & pumping set etc shall be arranged by the contractor and rate for the same will be deemed to be included in the quoted rate. 2. Contractor will dispose off the material taken out from the sump at a distance upto 50 Mtr as ddirected by Engieneer-in-Charge. 3. Contractor will clean the surroundings of Tank upto 3 mtr around the plinth of the tank. |
2 | All as per item No 01 above but cap upto 100000 GLNS |
3 | All as per item No 01 above but cap upto 200000 GLNS |
4 | All as per item No 01 above but cap upto 400000 GLNS |
5 | Cleaning inside RCC OH reservoirs capacity 375000 gallons at 22 metre staging including removing deposit sand from inside the tank scrubbing and washing side walls and bottom with bleaching powder solution and making surface free from any fungus deposits starins using wire brush filling of cavaties inside of tank with cm 1:1with quick cement and applying one coat of white washinside including dome & writing date of cleaning complete all as specified and directed including repair to wash out system if required for proper flushing of over head tank. Note :-1. All type of T&P and Labour etc shall be arranged by the contractor and rate for the same will be deemed to be included in the quoted rate. 2. Contractor will dispose off the material taken out from the Tank at a distance upto 50 Mtr as directed by Engieneer-in-Charge. 3. Contractor will clean the surroundings of Tank upto 5 mtr around from the plinth of the tank. |
6 | All as per item No 05 above but tank capacity 100000 gallons |
7 | All as per item No 05 above but capacity up to 50000 gallons. |
8 | M&L in repair aviation Light fitting 100 Watt 230 Volts 50 Hz yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories, complete all as specified and directed. |
9 | S&F in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240V,of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCBand with enclosure blank plates for unused way suitable for 02 way complete all as specified and directed. |
10 | S&F in repair MCB single pole & neutral16 Amps rating "C" Series 240 Volt complete all as specified and directed. |
11 | Supply and fixing PVC insulated & sheathed , heavy duty electric cable on RCC Piller /Dome of overhead tank at hight of 25 meter approximatelly from normal ground level incluiding fixing arrangementwith Copper conductor, multi stranded 1100 volts grade Flate 2 core 04 Sqmm and taking out of existing unserviceable cable complete all as specified and directed. Make : Havells/Plaza/ Rallison / Nicco / National. (Note : Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers andpipe shall be measured and paid separately under appropriate items.) |
12 | Taking out monoblock Pump set / Horizontal submersible pumping set upto 5 HP for FOUNTAIN at varrious location in catonment lucknowwith connected item such assuction pipe cable etc including disconnecting mechanically and electrically complete all as specified and directed. |
13 | Transportation ofmonoblock Pump set / Horizontal submersiblepumping set upto 5 HP from site (Lucknow Cantt) to contractor workshop and vice versa complete all as specified and directed. |
14 | Dismantlingmonoblock Pump set / Horizontal submersiblepumping set upto 5 HP for repair and reassembling after repair complete all as specified and directed. |
15 | Rewinding ofmonoblock Pump set / Horizontal submersiblemotor capacity 5 HP with Copper wire /PVC insulated copper wire of appropriate size, packing material etc including removal of unserviceable winding cleaning slots etc complete all as specified and directed. |
16 | All as per item No 15 above but cap 3 HP |
17 | All as per item No 15 above but cap 2 HP |
18 | All as per item No 15 above but cap 1 HP |
19 | Supply and fixing only in replacement of PVC insulated three core submersible cable 2.5 Sqmm complete all as specified and directed. Make : Finolex / L&T./PLAZA. (Note : Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers andpipe shall be measured and paid separately under appropriate items.) |
20 | Supply & fixing only in replacement of PVC insulated three core submersible cable 4.0 Sqmm complete all as specified and directed. Make : Finolex / L&T./PLAZA. (Note : Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers andpipe shall be measured and paid separately under appropriate items.) |
21 | Supply & replacement of DOL starter for three phase motor, 220 V upto 3 HP Motor complete all as specified and directed. Make : L&T / BCH. |
22 | Supply & replacement of DOL starter for three phase motor, 220 V5 HP Motor complete all as specified and directed. Make : L&T / BCH. |
23 | S&F GI nut, bolts each with 01 Nut and two Nos washers of any size and length complete all as specified and directed. |
24 | S&F terminal plate 3 phase six wire bakelite, star/delta connection as required at site with brass studs three nuts and two washers size 6 to 8 mm as per site requirement complete all as specified and directed. |
25 | S&F PVC fiber blades with split pin suitable for cooling system of motor to match with the fan cover as required at site for 3 HP to 5 HP motor complete all as specified and directed. |
26 | S&F ball/roller/thurst bearing of electric motor/pump sets including turning, polishing and greasing etc for Thurst bearing No. 6220/6218 sizes complete all as specified and directed. (Make of bearing - SKF/NMC) :- |
27 | All as per item No 26 above but Ball bearing No. 6314, 6315 ,6316. |
28 | All as per item No 26 above but Ball bearing No. 6311, 6312 ,6313. |
29 | All as per item No 26 above but Ball bearing No. 6308, 6309 ,6310. |
30 | All as per item No 26 above but Ball bearing No. 6201, 6202, 6203. |
31 | All as per item No 26 above but Ball bearing No. 6204, 6205, 6206. |
32 | Supply & replacement of gun metal bush bearing for the the following size of induction motor/pump including turning, polishing, greasing and remetaling of shaft etc for the Upto 3 HP sizes complete all as specified and directed. |
33 | All as per item No 32 above but 5/7.5 HP |
34 | All as per item No 32 above but 10 HP & above |
35 | Supply & fixing only Cast iron non return valve PN-1 flanged ends suitable for 150 mm bore including jointing material complete all as specified and directedMake : Zoloto/Leader/BIR/Upadhaya. |
36 | Supply and fixing Cast iron non return valve PN-1 flanged ends suitable for 200 mm bore including jointing material complete all as specified and directedMake : Zoloto/Leader/BIR/ Upadhaya |
37 | Supply and fixing cast iron Sluice valve PN-1.6 flanged ends suitable for 150 mm bore including jointing material complete all as specified and directed. |
38 | Painting of pipe lines with two coat of synthetic enamell paint as per colour code after cleaning and removing existing dust and dirt on existing painted surfaces of 200 mm bore vertical with over head tanks from GL upto 21 Mtr above GL complete all as specified and directed. (Note :The rate for scafolding etc deemed to be included in the quoted rates.) |
39 | All as per item No 38 above but 150/100mm bore vertical with over head tanks from GL upto 21 Mtr above GL |
40 | All as per item No 38 above but 150/200 mm bore horizontal/vertical pipe along with Sluice valve/ NRVat GL for header/inside/Outside of Pump House |
41 | All as per item No 38 above but 100/80 mm bore horizontal/vertical pipe along with Sluice valve/ NRVat GL for header/inside/Outside of Pump House |
42 | S&F ( in repairs)single phase preventor to prevent against single phasing, reverse phasing with wiring & testing, Model-VSP D2 complete all as specified and directed, Make : Minilac/L&T/ Telemecanique |
43 | Supply and fixing only in replacement of the water level indicator of OHT 21 head and 90 mtr apart from the tubewell complete kit in allmanners including taking down of old unserviceable spares complete all as specified and directed. Make : SM Instrumentation |
44 | S&Fcable joint kit suitable for 0.5 Sq mm 10 pairs ofcopper wirecableofwater level indicator complete all as specified and directed. |
45 | Repair to pipe line inside the RCC OH reservoir at an approx height 25Mtr above the normal GL for the Cutting in position 150 mm bore CI /DI pipe class "B" /K-9 complete all as specified and directed. |
46 | Supply & fixing in true vertical positionDI pipe 150mm bore class "B"/k-7 (as per existing). |
47 | CI Special as per site requirement. |
48 | Laying,fixing, jointing and testing only of solid PVC insulated , 10 pairs, individual shielded for interference rejection, armoured PVC sheathed 1100 Volts garde 0.5 sqmm instruemental cable ISI-5608 marked,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. including taking out unserviceable cable complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers andpipe shall be measured and paid separately under appropriate items. |
49 | Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide and geting out in soft/loose soil complete all as specified and directed. |
50 | Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
51 | Removing excavated material not exc 50 m and depositing where directed at a level not exc .5m above the starting point complete all as specified and directed. |
52 | Supply and spread fine dry sand locally available for cable cushioning complete all as specified and directed. |
53 | M&L for laying fly ash brick in trenches as cable protection covers across the length of the cable complete all as specified and directed. |
54 | Attending complaint to make automation system functional of 16 Nos pump houses (servicing and management distribution network) installed at various location at Lucknow cantt including replacement of mechanical/electrical/electronic parts and components of PLC based control panel complete all as specified and directed. (Make :- RDS/Simcom) Note :- (i) Maintenance daily under supervision of Engr-in-Charge. (ii) Fixing of defective spares/components are deemed to be included in the unit rate but cost of spares/components will be paid under respective items here in above. |
55 | Supply only Relay -04 C/O , 220V AC complete all as specified and directed. Make: LEONE/ IDEC/L&T |
56 | Supply only Relay -04 C/O , 224V DC complete all as specified and directed. Make: LEONE/ IDEC/L&T |
57 | Supply only Relay Port-4 C/O, 220V AC/ 24V DC complete all as specified and directed. Make: LEONE/ IDEC/L&T |
58 | Supply only LED indicator lamp of colour Red/ Yellow/ Green complete all as specified and directed. Make : ESBEE/Schneider/ Telemecanique |
59 | Supply only push button with LED indicator ,240 V AC, color : Red / Yellow / Green complete all as specified and directed. Make : ESBEE/ Telemacnique/Schneider complete all as specified &directed. |
60 | Supply only of SMPS 24 V DC, 3.2 Amp complete all as specified and directed. Make: Telemacnique/ NHP/Minilec |
61 | Supply only of Limit Switch for Actuator Suitable for 80 mm /100mm/ 150mm /200mm dia size with 1 NO & 1 NC complete all as specified and directed. |
62 | Supply only expansion adopter for PLC (programmable logic controller), complete all as specified and directed. Make : Unitronics / Allen Bradley / Siemens / Mitsubishi. |
63 | Supply only Handwheel for 80mm/100mm/150mm/200mm Actuators complete all as specified and directed. |
64 | Supply only Water Level Controller Relay Card (05 levels), complete all as specified and directed. Make : Crystal/Techtrol/Mahalaxmi/SM Instrumentation |
65 | Supply only step down transformer input 230 V AC,Output 12V DC, 2 Amp rating complete all as specified and directed. Make:- AIM |
66 | M & L for panel wiring using PVC insulated 0.5 Sqmm copper wire complete all as specified and directed. |
67 | Servicing of motorised Butterfly Valve of sizes 80 mm /100 mm/150mmi.e. removing , cleaning ,greasing, refixing and recommissioning for wear & tear complete all as specified and directed. Note:- Spares shall be measured and paid separately if needed. |
68 | Servicing of motorised Butterfly Valve of sizes 200/250i.e. removing , cleaning ,greasing, refixing and recommissioning for wear & tear complete all as specified and directed.Note: Spares shall be measured and paid separately if needed. |
69 | S & F of Actuator Adoptor with key for 150 mm dia butterfly Valve complete all as specified and directed. |
70 | Supply only Electric motor suitable for Actuator for 100 mm dia butterfly Valve complete all as specified and directed. Make : SD Torque /Marsh/ Emtork / Prosyn / SM Instrumentation) |
71 | Supply only Electric motor suitable for Actuator for 150 mm dia butterfly Valve complete all as specified and directed.Make : SD Torque /Marsh/ Emtork / Prosyn / SM Instrumentation) |
72 | Supply only Electric motor suitable for Actuator for 200 mm dia butterfly Valve complete all as specified and directed.Make : SD Torque /Marsh/ Emtork / Prosyn / SM Instrumentation) |
73 | Supply only Electric motor suitable for Actuator for 250 mm dia butterfly Valve complete all as specified and directed. Make : SD Torque /Marsh/ Emtork / Prosyn / SM Instrumentation) |
74 | Supply, Installation, testing & commissioning of flow/ pressure switch 1-10Kg/Sq cm in replacement alongwith all necessary installation accessories like wiring, GI barrel piece, double nipple etc complete all as specified and directed. Make : RAPID CONTROL/INDFOSS/DANFOSS. |
75 | Supply, installation, Testing & commissioning PLC having minimum 12 inputs and 9 outputs with inbuilt power supply and HMI, 24V DC auxiliary supply complete all as specified and directed. Make : UNITRONICS / ALLEN BRADLEY / SIEMENS / MITSUBISHI/ DELTA |
76 | Supply & fixing in replacement six core, 1.5 sqmm nominal cross sectional area, multistranded armoured copper conductor cables, 1100 volts grade heavy duty cable PVC insulated and PVC sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc complete all as specified and directed. |
77 | Supply & fixing in replacement four core, 1.5 sqmm nominal cross sectional area, multistranded armoured copper conductor cables, 1100 volts grade heavy duty cable PVC insulated and PVC sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc complete all as specified and directed. |
78 | Supply & fixing in replacement five pair, 0.5 sqmm nominal cross sectional area mulistranded copper conductor cables, 1100 volts grade heavy duty cable PVC insulated and PVc sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etccomplete all as specified and directed. |
79 | Supply, Installation, Testing and commissioning of motor actuated butterfly valve in replacement withthe following specifications including allaccessories mentioned as under (a) Valve size 250mm dia (b) Designed line pressure 4 kg/Sqcm (c) Operating Angle : 90 degrees (d) Disc material CI with nylon coating (e) Limit switches : 02 Nos for open and close (f) Mounting : Splash proof-Direct on valve (g) Input Supply : 230V, AC, 50 HZ (h) In built wireless modem compatibility for remote communication (j) Valve position indication with an output of 4-20m A (k) The actuator should be capable of accepting 4-20m A of input of regulating purposes (l) Mannual Operation : Hand Wheel Make : ROTORK/EMTORK/ HASSEL/SM INSTRUMENTATION/SD TORQUE |
80 | Supply, Installation, Testing and commissioning of motor actuated butterfly valve replacement with the following specifications including allaccessories job mentioned as under (a) Valve size 150mm dia (b) Designed line pressure 4 kg/Sqcm (c) Operating Angle : 90 degrees (d) Disc material CI with nylon coating (e) Limit switches : 02 Nos for open and close (f) Mounting : Splash proof-Direct on valve (g) Input Supply : 230V, AC, 50 HZ (h) In built wireless modem compatibility for remote communication (j) Valve position indication with an output of 4-20m A (k) The actuator should be capable of accepting 4-20m A of input of regulating purposes (l) Mannual Operation : Hand Wheel Make : ROTORK/EMTORK/HASSEL/SM INSTRUMENTATION/SD TORQUE |
81 | Supply, Installation, Testing and commissioning of motor actuated butterfly valve replacemment with the following specifications including allaccessories job mentioned as under (a) Valve size 100mm dia (b) Designed line pressure 4 kg/Sqcm (c) Operating Angle : 90 degred (d) Disc material CI with nylon coating (e) Limit switches : 02 Nos for open and close (f) Mounting : Splash proof-Direct on valve (g) Input Supply : 230V, AC, 50 HZ (h) In built wireless modem compartibility for remote communication (j) Valve position indication with an output of 4-20m A (k) The actuator should be capable of accepting 4-20m A of input of regulating purposes (l) Mannual Operation : Hand Wheel Make : ROTORK/EMTORK/ HASSEL/SM INSTRUMENTATION/SD TORQUE |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy