| 1 | Entrance Gate |
| 2 | Providing design detaling and analysis |
| 3 | Providing, fabricating, assembling and erection of pre stressed Tensile Membrane Fabric in desired profile as per conceptual drawing with Serge Ferrari PRECONTRAINT having minimum Tensile strength (Warp/Weft) 280/280daN/50 mm & minimum tear strength (Warp/Weft) of 30/28daN, high concentrated PVDF top coating and PVDF coated on bottom side, polyester fabric and should be weldable having a minimum weight of 950 gm/sqm with a minimum 20 years warranty etc.Rate includes cost of fabric, patterns, forming, cutting, fabrication, hot weld stitch of fabric, assembling and installation with ALUMINUM strands, hardware, EPDM gasket and required accessories |
| 4 | Providing, Design Detailing ,Fabricating, Assembling, hoisting, erecting and placing in position OF Ms Structure with epoxy paint after processing of sand blastting |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : |
| 6 | Foundations, footings, bases of columns, etc. for mass concrete |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 8 | 1:1.5:3 (1 cement :1.5 coarse sand (zone-III): 3 graded stoneaggregate 20 mm nominal size). |
| 9 | SteelreinforcementforR.C.C.workincludingstraightening,cutting,bending, placing in position and binding all complete upto plinth level. |
| 10 | Thermo-Mechanically Treated bars of grade Fe-500 or more. |
| 11 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
| 12 | All kinds of soil |
| 13 | Supplyingandfillinginplinthwithsandunderfloor,includingwatering, ramming, consolidation and dressing complete. |
| 14 | Supply and installation of 9W LED spike light with lumens > 800 lms, Power factor > 0.95, CRI > 80 with IP66 and IK07 Gray pure polyester powder coated ,Pressure die-cast aluminium housing for efficient thermal management, sturdiness & excellent corrosion resistance & High quality toughened glass in clear finish for uniform light distribution.The housing provides IP66 protection for high reliability in outdoor applications. High efficiency long life COB LED mounted on MCPCB of fixture. Lumen efficacy of LED >140 lm/W. . with aluminum heat sink for effective thermal management with Operating temperature: -10°C to +45°C.Havells LYCUSSPS9WLED730PSYMBOTG. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, Is 10322/IEC 60598 and for LEDs - LM80, RoHS and Photo Biological Safety certificate. |
| 15 | Supply of IP 66 LED light with Housing made ofDie Cast Aluminum, wattage not exceeding 45 W with lumen output of note less than 2700. Luminaire has a choice of architectural floodlighting optics with beam angles of 10°/25°/40°/60°/25°x60° degree as per the site conditions. Fixture should be with Die Cast Aluminum, powder-coated finish RAL7040.Luminaire should be capable of operating at separate loop line for control wires so that all the lights keep working during malfunctioning of any cables or short circuiting. Should be able to work in the voltage range of 100-270 V AC. Lifetime should be at least 50,000 burning hours at L70 at 50 degree centigrade with total IP66 protection should be provided. Certifications Third party NABL/UL / cUL, Temperature Range 0ºC to 45ºCstart-up temperature, 0ºC to 50ºC operating temperature. Work should be complete with necessary factory made weather proof cable, lenses, and external power & data supply , wiring, junction boxes, provisioning of power and data cabling etc. as required. The luminaire manufacturer shall provide optical performance, polar diagrams and photometric data in various formats including IES file format in accordance with IES LM-79-08.THD should be less than 10, ENEC, CE approved driver will be required. The supplier will be required to Produce IEC60598 from third party NABL Laboratory with all relevant tests Heat Resistance Test, Thermal Test, Ingress Protection Test, Electrical / Insulation Resistance Test, Endurance Test, Humidity Test.. LED make should be only Nichea, Osram, Cree, Lumiled. Havells Ranger Mini 45W LED LHEPBNU5P47J045 |
| 16 | Providing supplying & installation Park Bench, Material: Stainless Steel, Grade: SS 304, Fixings: Root fixed Fixing: Surface / base plate fixed Seat length (mm):2000/2600 Seat depth (mm) 480 Above ground height (mm) 427 Seat height (mm) 427 |
| 17 | Scoffolding |
| 18 | Transport cost |
| 19 | Pond Rejuvenation - Earthwork |
| 20 | Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layerwith ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m : |
| 21 | All kinds of soil |
| 22 | Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 23 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m. |
| 24 | Pond Rejuvenation - METAL WORKS (RAILING) |
| 25 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 26 | Pond Rejuvenation - Flooring |
| 27 | Laying of 25 mm thick Kota stone of size 45X 45cm and above flooring over Previously prepared base with 2cm thick 1:3 cement and sand mortar including filling of joints with cement mixed with pigment required for matching the shade of floor as per the direction of E/I including cutting polishing with wax polish including supply of all material T&P etc. required for proper completion of work. |
| 28 | Laying of 25 mm thick Kota stone of size 45X 45cm and risers, dado over Previously prepared base with 2cm thick 1:3 cement and sand mortar including filling of joints with cement mixed with pigment required for matching the shade of floor as per the direction of E/I including cutting polishing with wax polish including supply of all material T&P etc. required for proper completion of work. |
| 29 | Providing and fixing 18 mm thick gang saw cut mirror polished (premoulded and prepolished) machined cut for kitchen platforms,vanity counters, window sills,facias and similar location of required size of approved shade, colour and texture laid over 20mm thick base cement mortae 1:4 (1cement :4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding & polishing to edge to give high gloss finish etc. complete in all levels. |
| 30 | Granite of any colour or size |
| 31 | Area of slab over 0.5 sqm |
| 32 | Pond Rejuvenation - Site Development Work |
| 33 | Providingandlayingfactory made 60mmthickrubber moulded interlocking cement concrete tiles (30mpa) including 25 mm thick compacted bed of fine sand compacting and propper embedding/ laying of interlocking tiles levelling and dressing of surfaces to required level and slope, filling joints with fine sand, including cost of material, cost, T&P etc. required for proper completion of work as directed by Engineer-In -Charge. |
| 34 | Providing and laying at or near ground level factorymadekerbstoneofM-25grade cement concrete in positionto the required line, level and curvature, jointed with cement mortar 1:3 (1 cement:3coarsesand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge(lengthof finishedkerb edgingshallbemeasuredforpayment). (Precast C.C. kerb stone shall be approvedby Engineer-in-charge). |
| 35 | Pond Rejuvenation - CONCRETE WORK |
| 36 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 37 | 1:11/2:3 (1 Cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 38 | 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) |
| 39 | Pond Rejuvenation - BRICKWORK |
| 40 | M 150 class brick work in 1:4 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of work. |
| 41 | M 150 class brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of work. |
| 42 | Brick work with(non modular)fly ash lime bricks (Flag Bricks) conforming to IS :12894, class designation 10 averages compressive strength in superstructure. |
| 43 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 44 | Cement mortar 1:6 (1 cement : 6 coarse sand |
| 45 | Pond Rejuvenation - FINISHING WORK |
| 46 | Finishing walls with textured exterior paint of required shade : |
| 47 | New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied@ 2.20kg/10 sqm |
| 48 | Pond Rejuvenation - LANDSCAPE WORK (Supply of Plants) |
| 49 | Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. |
| 50 | Providing and displaying of Phoenix palm having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 51 | Providing and stacking of Plumeria alba of height 165-180 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. |
| 52 | Pond Rejuvenation - LANDSCAPE WORK (Ground Cover) |
| 53 | Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Poly bags & as per direction of the officer-in-charge. |
| 54 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal ofunserveiceable material’s as per direction of officer in charge (excludingcast of plant & water) |
| 55 | Pond Rejuvenation - LANDSCAPE WORK (Miscellaneous) |
| 56 | Providing, Supplying & installation at site gym equipments complete with all accessories as per specification or as directed by Engineer - In -Charge. |
| 57 | Providing supplying & installation Park Bench, Material: Stainless Steel, Grade: SS 304, Fixings: Root fixed Fixing: Surface / base plate fixed Seat length (mm):2000/2600 Seat depth (mm) 480 Above ground height (mm) 427 Seat height (mm) 427 |
| 58 | Bollard: LED bollard with opal acrylic diffuser and IP 65 protection, Bajaj BGBOM 650 9W LED WW or Equivalent, installation with cables/connections |
| 59 | Garden Spike 12 W:-Supply, Installation, Testing and Commissioning of LED Spike light with a system wattage of 12W, having Aluminium housing and anthracite body color.Weather proof IP 65 suitable for outdoor applications,Similar to Philips make Garden spike light Model No: 31386 |
| 60 | Pond Rejuvenation - LANDSCAPE WORK (SITE CLEARING) |
| 61 | Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). |
| 62 | Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) |
| 63 | Screened through sieve of I.S. designation 16mm |
| 64 | MISCALLANEOUS COST |
| 65 | Providing, Supplying, Installation/erecting digital water ATMComplete in all respect with all accessories, arrangement or as per direction of Engineer-In-Charge. |
| 66 | Providing, Supplying, Installation/erecting and testingof Prefab Single toilet block Structure,Complete in all respect with all accessories, Arrangementas, lift etc asper approved layout and material specification, or as per direction of Engineer-In-Charge. |
| 67 | Septage Treatment Plant - 5 KLD |
| 68 | Design, Supply, Construction, testing and commissioning of 5 KLD Capacity Septage Treatment Plant based on Activated Sludge Process / MBBR process with all necessary unit, piping etc complete including E&M works, civil works as per approved design and technical specification analysis. |
| 69 | Providing, Supplying, Installation and testing of 2 Wheel Trailer Mounted Suction Machine having 1000 Ltrs Tank Capacity complete with all respect (I.e tank. Compressor, Suction pump or other accessories), as per Specification or as per the direction of Engineer-In-Charge. |
| 70 | Providing, Supplying, Installation and testing of 2 Wheel Trailer Mounted Suction Machine having 2000 Ltrs Tank Capacity complete with all respect (I.e tank. Compressor, Suction pump or other accessories), as per Specification or as per the direction of Engineer-In-Charge. |
| 71 | Septage Treatment Plant - 5 KLD (Opex) |
| 72 | Design, Supply, Construction, testing and commissioning of 5 KLD Capacity Septage Treatment Plant based on Activated Sludge Process / MBBR process with all necessary unit, piping etc complete including E&M works, civil works as per approved design and technical specification analysis including operation maintenance for 1 years on turnkey basis. |
| 73 | O&M Works 1 year |
| 74 | Solid Waste Management - Procurement of Primary, Secondary Collection & Transportation |
| 75 | Truck Tippers tippers |
| 76 | Tricycles |
| 77 | Solid Waste Management - Procurement of Waste storage Bins |
| 78 | Bins-1100 ltrs |
| 79 | Bins-250 ltrs |
| 80 | Litter Bins |
| 81 | Solid Waste Management - Procurement of Other Accessories |
| 82 | Wheel Barrows |
| 83 | Brooms |
| 84 | Metal trays |
| 85 | Caps |
| 86 | Boots |
| 87 | Masks |
| 88 | Gloves |
| 89 | Storage |
| 90 | Storm Water Drainage System |
| 91 | Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 92 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m. |
| 93 | By Mechanical Transport including loading,unloading and stackingBy Mechanical Transport including loading,unloading and stacking |
| 94 | Earth |
| 95 | lead of3 Km |
| 96 | Earth |
| 97 | lead of5 Km. |
| 98 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering. |
| 99 | 1:3:6 (1 Cement : 3 coarse sand(Zone III) : 6 graded stoneaggregate 20 mm nominal size) |
| 100 | 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 101 | Centring and shuttering including strutting, propping etc. andremoval of form for all heights: |
| 102 | Foundations, footings, bases of columns etc. for mass concrete. |
| 103 | M 150 class brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of work. |
| 104 | Cement Mortar 1:6 |
| 105 | 12mm thick cement plaster of mix: |
| 106 | 1:4 (1 cement : 4 coarse sand) |
| 107 | Neat Cement Punning |
| 108 | Supply & Fixing of 100 mm thickPerforated drain cover including RCC work in M-15, Steel reinforcement, necessary form work etc complete all as per direction of Engineer-In-Charge. |
| 109 | Supply & Fixing700 |
| 110 | Supply & Fixing800 |
| 111 | Electrical Streetlights |
| 112 | Solar Based Street Light with PoleLED: 12W, Solar Panel: 9W/18V, Battery: 12.8V/ 16.5 AH, IP65 Waterproof Housing. Solar Charging Time: 10 Hours. |
| 113 | Installation & Commissioning of Solar Street Light |
| 114 | Foundation Charge for Street Pole with Pole Mounting Accessories |
| 115 | Solar Based Reading LightLED: 10W, Solar Panel: 6W, Battery: 3.2V/ 14 AH, IP65 Waterproof Housing.Solar Charging Time: 8 Hours. |
| 116 | Installation & Commissioning of Solar Reading Light |
| 117 | Road Improvement- CC Road |
| 118 | Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. |
| 119 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ lesscement used as per design mix is payable/recoverable separately). |
| 120 | Cement concrete prepared with batch mixing machine. |
| 121 | Corporate Branding |
| 122 | Supply and instalation of Iron frame made of 50 X 50 mm with ACP base to paste the digital graphic directly over ACP with the proper fixing detail. Size - 3ft X 5ft (on both sides) |
| 123 | Providing and Fixing as per control Sample Sleek Double Sided suspended LED Illuminated powder coated profiled aluminum extrusions box maximum 55mm thick signage with art panel in colored vinyl sheet on acrylic as per design with powder coated suspension system. The Signage shall have an easy mechanism of removing the content /Information for inspection and access of the services. Suspender height upto 2.5m included (300 X 300) on both sides |
| 124 | Park Sign (Notification)Sign Size of 3\" x 2\", Stand height - 6 feet, double leg stand on 2\" x 2: MS pipe with Powder coating, both leg with bottom plat for fastening, 3mm ACP base with weather proof vinyl print pasted |
| 125 | Contigencies @3% (Including Geo-tehnical Investigation, Survey and Structural design/Report) |