Repair / Maint Of External Electric Supply, Lt Over Head Line, Lt Ug Cable And Allied Works At Zone-1 ( A, B, C ) , Zone-2, Zone-3A, 3B, Zone-4 And Zone-5 Under Ge ( S ) Tezpur, tezpur-Assam

Military Engineer Services-MES has published Repair / Maint Of External Electric Supply, Lt Over Head Line, Lt Ug Cable And Allied Works At Zone-1 ( A, B, C ) , Zone-2, Zone-3A, 3B, Zone-4 And Zone-5 Under Ge ( S ) Tezpur. Submission Date for this Tender is 31-05-2022. Overhead Line Tenders in tezpur Assam. Bidders can get complete Tender details and download the document.




Tender Notice

32004536
Corrigendum : Repair / Maint Of External Electric Supply, Lt Over Head Line, Lt Ug Cable And Allied Works At Zone-1 ( A, B, C ) , Zone-2, Zone-3A, 3B, Zone-4 And Zone-5 Under Ge ( S ) Tezpur
Open Tender
Indian
Assam
tezpur
31-05-2022

Tender Details

Repair / Maint Of External Electric Supply, Lt Over Head Line, Lt Ug Cable And Allied Works At Zone-1 ( A, B, C ) , Zone-2, Zone-3A, 3B, Zone-4 And Zone-5 Under Ge ( S ) Tezpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-May-2022 Amdt date Date 24-05-2022
2 24-May-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 31-05-2022
3 31-May-2022 Due Date Extended - (31-05-2022) Admin Corrigendum Date Extend 01-06-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 100000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repair/maint of external electric supply LT over head line LT UG cable and allied works atZone-1 (A,B,C), Zone-2, Zone-3A & 3B,Zone-4 and Zone-5 under GE (S) Tezpur
Sl. No. Item Description
1Labour to re-stringing/ tilting, clamping, bending , jumpering,etc to be removing excess sag ofloose ACSR of over head line upto permissible sag at camp area using accessories, T&P such as manila rope, puller and tripod etc upto permissible sag between two poles to continiously upto terminating point of tightening of stay strand in proper angle etc all as per site requirement and directed Note :-(i)Three/ four/six/eightruns of ACSR shall be measured against one unit. (ii)Quoted rates shall be included for all required T&P and safety equipment.(iii) Span Between two consecutive poles shall be measured as one unit.
2Supply and fixing in replacement to old by new Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size all as specified and directed. Note :- Instruction shall be written in three lauguage Hindi, English and Assami on notice board.
3Supply and fixing in replacement to old by new Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size all as specified and directed. Note :- Instruction shall be written in three lauguage Hindi, English and Assami on notice board.
4M&L in replacement Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole all as speccified and directed by Engr-in-charge.
5M&Lin replacement of Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed .
6Dismantling/ taking down old insulator any type and size for 1100 volts grade as available at site all as directed.
7Supply and fixing of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for working pressure 1100 volts grade complete all as specified anddirected .
8Supply and fixing of Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, suitable for 1100 Volts, Height 100 mm, Width 115 mm including galvanised strap 31 x 5 mm, Nut bolts 14 mm and Washer 3 mm thick as under: complete all as specified and directed.
9Supply and fixing of Loop type insulator, vitreous porcelain, white, brown or green, Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and directed.
10M&L for in replacement of Stay assembly 16 mm dia stay rod complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) complete all as specified and directed . Note :Loop type insulator, excavation, earth work and concrete to be measured and paidagainst the respective item.
11Supply and fixing in replacement of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long).All as specified and as directed.
12M&L for in replacement of Galvanised stay strand (Grade 2), size 7/4.0 mm mm complete all as specified and directed.
13M&L for in replacement of Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia all as site required all as directed.
14M&L for re-fixing/ titing/ bending /cradles, hexagonal/ rectangular, fabricatednet in proper gap etc all as site to old galvanised wire in any size assafe guard of HT/LT over head line with fixing as directed.
15Re-fixing only with tilting/ jointing/ bending/ jumpering etc all as site toaluminium conductor steel reinforced (ACSR) in any size/ dai/ type etc on existingpoles using puller/ rope/ tripod etc to re-staching in permiceable sag all as directed.
16Supply andfixing in replacement of Aluminium conductor, steel reinforced complete all as specified and directed .
17Supply and fixing in replacement of House service bracket (hook type complete with 3.0m long G.I. pipe 50 mm dia Med. grade, two nos 90 degree bends. M.S. hook and stay or guy complete all as site and directed..
18Supply and fixing in replacement of the following cable end/ straight termination jointing kit ,1100 volt grade (earthed) , 3.5 core 400 sqmm aluminium conductor XLPE insulated armoured heavy duty cable heat shinkable suitable in/ out door type to be fix on incoming /outgoing connection of LT panel with gland etc at various location for following size :-. Make - Dension / Raychem / 3M
19All as in Item No - 18 but for 3.5 core 185 to 300 Sqmm
20All as in Item No - 18 but for 3.5 core 90 to 150 sqmm
21All as in Item No - 18 but for 3.5/4 core 25 to 70 Sqmm
22All as in Item No - 18 but for 3.5/4 core upto 16 sqmm
23Supply and fixingin replacement of MCCB 4 Pole, 415 V, with Microprocessor release 125 Amps with breaking capacity 36 KA Make - Havells/ Legrand / Seimens Note :- All MCCBs of schedule shall be conforming Ics= 100% Icu as per IEC 60947 -2 and front LED indication (ready, overload pre-alarm & over load). Make - Seimens/L&T/Schnieder/ABB/Havells/Indoasian/Legrand
24Supply and fixing in replacement ofMCCB 4 Pole, 415 V, with Microprocessor release 160 Amps with breaking capacity 36 KA Make - Havells/ Legrand / Seimens Note :- All MCCBs of schedule shall be conforming Ics= 100% Icu as per IEC 60947 -2 and front LED indication (ready, overload pre-alarm & over load). Make - Seimens/L&T/Schnieder/ABB/Havells/Indoasian/Legrand
25Supply and fix MCCB 4 pole, microprocessor based Release range250 Amps,415V,AC,50Hz ,36 KAManual versions With Conforms to IS/IEC 60947-2,Ics=100% Icu,Suitable for Isolation Adjustable Over Load setting: 0.4 - 1.0 x In ,Adjustable Short Circuit setting: 1.5 - 10 x Ir , ,Wide Range of snap fit Internal and External Accessories including Taking down old MCCB all as specified and directed by Engineer-in-chargend Make - Seimens/L&T/Schnieder/ABB/Havells/Indoasian/Legrand
26Supply and fix MCCB 4 pole, microprocessor based Release range400 Amps,415V,AC,50Hz ,36 KAManual versions With Conforms to IS/IEC 60947-2,Ics=100% Icu,Suitable for Isolation Adjustable Over Load setting: 0.4 - 1.0 x In ,Adjustable Short Circuit setting: 1.5 - 10 x Ir , ,Wide Range of snap fit Internal and External Accessories including Taking down old MCCB all as specified and directed by Engineer-in-chargendMake - Seimens/L&T/Schnieder/ABB/Havells/Indoasian/Legrand
27Supply and fix MCCB 4 pole, thermal magnetic based Release range 100 Amps,415V,AC,50Hz ,36 KAManual versions With Conforms to IS/IEC 60947-2,Ics=100% Icu,Suitable for Isolation Adjustable Over Load setting: 0.8 - 1.0 x In ,Adjustable Short Circuit setting: 6 - 10 x In , ,Wide Range of snap fit Internal and External Accessories including Taking down old MCCB all as specified and directed by Engineer-in-charge.Make - Seimens/L&T/Schnieder/ABB/Havells/Indoasian/Legrand
28Supply and fix MCCB 4 pole, thermal magnetic based Release range 250 Amps,415V,AC,50Hz ,36 KAManual versions With Conforms to IS/IEC 60947-2,Ics=100% Icu,Suitable for Isolation Adjustable Over Load setting: 0.8 - 1.0 x In ,Adjustable Short Circuit setting: 6 - 10 x In , ,Wide Range of snap fit Internal and External Accessories including Taking down old MCCB all as specified and directed by Engineer-in-charge.Make - Seimens/L&T/Schnieder/ABB/Havells/Indoasian/Legrand
29Supply and fixing in replacement of MCBs , 240 Volts grade , DP ,"B" curve , 63 Amps complete all as specified and directed by Engr-in-charge. Make - Seimens/L&T/Schnieder/ABB/Havells/Indoasian/Legrand
30Supply and fixing in replacement of MCBs , 240 Volts grade , DP ,"B" curve , 40 Amps complete all as specified and directed by Engr-in-charge. Make - Seimens/L&T/Schnieder/ABB/Havells/Indoasian/Legrand
31Supply and fixing in replacement of MCBs , 240 Volts grade , SPN, single pole and neutral link ,"C" curve , 63 Amps complete all as specified and directed by Engr-in-charge. Make - Seimens/L&T/Schnieder/ABB/Havells/Indoasian/Legrand
32Supply and fixing in replacement of MCBs , 240 Volts grade , SPN, single pole and neutral link ,"C" curve , 40 Amps complete all as specified and directed by Engr-in-charge. Make - Seimens/L&T/Schnieder/ABB/Havells/Indoasian/Legrand
33Supply and fixing in replacement of MCBs , 240 Volts grade , SP, single pole ,"B" curve , 6 to 32 Amps complete all as specified and directed by Engr-in-charge. Make - Seimens/L&T/Schnieder/ABB/Havells/Indoasian/Legrand
34Supply and fixing in replacement of MCBs , 240 Volts grade , SP, single pole ,"C" curve , 20 to 32 Amps complete all as specified and directed by Engr-in-charge. Make - Seimens/L&T/Schnieder/ABB/Havells/Indoasian/Legrand
35Supply, ffixing and connecting in replacement of Manual change over switch with sheet steel enclosure rating 125 Amps 4 pole, 440 volts grade in sheet metal enclouser conforming to IEC 60947-3, IS/IEC 60947 -3 fixing in panel/ surface of wall on wooden board with making all coonection, gland etc all assite and directed. Make - Seimens/L&T/Schnieder/ABB/Havells/Indoasian/Legrand
36Supply, ffixing and connecting in replacement of Manual change over switch with sheet steel enclosurerating 200 Amps 4 pole, 440 volts grade in sheet metal enclouser conforming to IEC 60947-3, IS/IEC 60947 -3 fixing in panel/ surface of wall on wooden board with making all coonection, gland etc all assite and directed. Make - L&T/Siemens/ Phillips/ Havells/ ABB
37Supply, ffixing and connecting in replacement of Manual change over switch with sheet steel enclosurerating 400 Amps 4 pole, 440 volts grade in sheet metal enclouser conforming to IEC 60947-3, IS/IEC 60947 -3 fixing in panel/ surface of wall on wooden board with making all coonection, gland etc all assite and directed.Make - L&T/Siemens/ Phillips/ Havells/ ABB
38Supply /laid/ fixing/ connecting and testing in replacement ofthe following LT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor , 1100 volts grade (earthed) cross section area 240 Sqmm x 3.5 core. Make - Havells/Gloster/Polycab/KEI
39All as in Item No-38 but for 185 Sqmm x 3.5 core
40All as in Item No-38 but for 150 Sqmm x 3.5 core
41All as in Item No-38 but for 120 Sqmm x 3.5 core
42All as in Item No-38 but for 95 Sqmm x 3.5 core
43All as in Item No-38 but for 70 Sqmm x 3.5 core
44All as in Item No-38 but for 50 Sqmm x 3.5 core
45All as in Item No-38 but for 35 Sqmm x 4 core
46All as in Item No-38 but for 35 Sqmm x 3.5 core
47All as in Item No-38 but for 25 Sqmm x 4 core
48All as in Item No-38 but for 16 Sqmm x 4 core
49All as in Item No-38 but for 10 Sqmm x 4 core
50Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose for laying cables, etc. complete all as specified and as directed.
51Returning, fillingincluding spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soilcomplete all as specified and as directed.
52Removing surplus excavated soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed..
53M&L forsand cushioning with clean dry sand for protection of under ground cable complete all as specified and as directed. Note :-Punned thickness of sand layer shall be measured abd paid to contractor.
54M&Lin replacement of Brick tiles; common burnt clay building bricks sub-class ‘B’ Designation 75laid in trenches with width equal to length of the bricks, above sand cushioning for cable protection completeall as specified and as directed.
55Labour for horizontal boring of Road/path for cable passing through complete all as specified
56S & F in replacement cable route indicator for LT UG cable of 1100 Volt grade bolted with 40 x 6 mm flat iron member of height 1 Mtr duly painted , embedded, in PCC 1:3:6 type C2 of size 20 x 20 x 30 cm block complete all as specified and directed
57M&L for cement conrete in foundation filling and mass concrete type C-2 in ration 1:3:6 using 40 mm graded aggregate all as directed.
58M&L for cement conrete in foundation filling and mass concrete type D-2 in ration 1:4:8 using 40 mm graded aggregate all as directed.
59M&L for cement conrete in coping filling and mass concrete type B-1 in ration 1:2:4 using 20 mm graded aggregate all as directed.
60Supply/ laid/ fixingin replacement of galvanised steel water tubing light grade bore of dia 80 mm with all fittings all as site and directed. Make - Tata / Jindal / NTL
61Supply/ laid/ fixingin replacement of galvanised steel water tubing light grade bore of dia 50 mm with all fittings all as site and directed. Make - Tata / Jindal / NTL
62Supply/ laid/ fixingin replacement of galvanised steel water tubing light grade bore of dia 40 mm with all fittings all as site and directed. Make - Tata / Jindal / NTL
63M&L for jointing/ cutting/ welding/ replacing hingesetc all as site required to LT panel made out MS sheet and angle for making smoth opening and closing complete with re-painting as same macthing with exsiting surrface all as directed.
64M&L for painting to electric pole steel tubular/ PCC after removing /scraping/ bruses/ cleaning to old painton external surface intwo coats of paint over one coats of red oxide primer by using syenthatic enamel aluminium paint on steel tubular and cement paint on PCC poles in any height/ length/ dai etcincluding cross arms/ angles, nut, bolt , washers etc and making alternate strip in 30 cm minium width upto 1.5 Mtr above normal GL and marking as direction using diffrent colour of paint complete all as site and directed by Engr-in-Charge. Note : Colour of paint shall be approved by Engr-in-charge.
65M&L for painting to two pole structure after removing /scraping/ bruses/ cleaning to old painton external surface intwo coats of paint over one coat of red oxide primer by using synthetic enamel aluminium paint on steel tubular and cement on PCC pole structurein any height/ length/ dia etc,including cross arms/ angles, nut, bolt , washers etc and making alternate strip in 30 cm minium width upto 1.5 Mtr above normal GL and marking as direction using diffrent colour of paint complete all as site and directed by Engr-in-Charge. Note : Colour of paint shall be approved by Engr-in-charge.
66M&L for painting to three pole structure after removing /scraping/ bruses/ cleaning to old painton external surface intwo coats of paint over one coat of red oxide primer by using synthetic enamel aluminium paint on steel tubular and cement on PCC pole structurein any height/ length/ dia etc,including cross arms/ angles, nut, bolt , washers etc and making alternate strip in 30 cm minium width upto 1.5 Mtr above normal GL and marking as direction using diffrent colour of paint complete all as site and directed by Engr-in-Charge. Note : Colour of paint shall be approved by Engr-in-charge.
67M&L for painting to four pole structure after removing /scraping/ bruses/ cleaning to old painton external surface intwo coats of paint over one coat of red oxide primer by using synthetic enamel aluminium paint on steel tubuler and cement on PCC pole structurein any height/ length/ dia etc,including cross arms/ angles, nut, bolt , washers etc and making alternate strip in 30 cm minium width upto 1.5 Mtr above normal GL and marking as direction using diffrent colour of paint complete all as site and directed by Engr-in-Charge. Note : Colour of paint shall be approved by Engr-in-charge.
68Supply and fixingin replacement of chain link MS galvanisd fencing, any size or type complete. Note - Size shall be approved by Engr-in-chagre.
69Demolition of Un einforced cement concrete in ground floor. complete all as directed
70Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness.Copmlete all as specified and as directed.
71M&L forin replacement of mild steel plates plain or chequered 5 mm thick or over in thicknessin size as per exsiting cable trench for giving protection to cable fe 410 -W graded -E- 250 quality B all as specified and directed.
72M&L for spares to be fitted in LT panel are as under : - Make :- L&T / Schneider / Legrand/AE (a)Selector switch
73All as per Item No 72 but Indicators in LED three colour (set of three)
74All as per Item No 72 but Digital volts meter rating 0 to 500 volts
75All as per Item No 72 but Digital Ameter ranee 500 Amps with CTs
76Material and Labour for in replacement of Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including excavation, earth work, testing on completion all as specified and directed.
77Material and Labour for in replacement of Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth lead iron strip 32X6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including excavation, earth work, testing on completion all as specified and directed.
78Supply and fixing in replacement of Test point terminal block made of gun metal or phosphorus bronze in size 75x75x25 mm drilled and screwed including 03 nos ,8 mm dai 25 mm long hex head screw complete all as specified and directed.
79S & F LT in replacement overhead PVC line spacers as per the existing site requirement complete all as specified and directed.
80Supply and fixing in replacement of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection.Make-Havells,Cat No-ENDURACITYLITEPLAT PLUSSL35WLED757SASYBOPC or equivalent make of Phillips/Bajaj/HPL
81Supply and fixing in replacement of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection Make-Havells,Cat No-ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent make of Phillips/Bajaj/HPL
82Supply and fixing in replacement of LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.Make-Havells,Cat No-JETA PROFL70WLED757LT G or equivalent make of Phillips/Bajaj/HPL
83Supply and fixing in replacement of LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.Make-Havells,Cat No-JETAIRISFLS 100WLED757SYMLT Gor equivalent make of Phillips/Bajaj/HPL
84Supply and fixing in replacement of LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.Make-Havells,Cat No-JETAIRISFLS 120WLED757SYMLT G or equivalent make of Phillips/Bajaj/HPL
85Supply and fixing in replacement of LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.Make-Havells,Cat No-JETA VALOURFL200WLED757PINTNBLT G or equivalent make of Phillips/Bajaj/HPL
86Supply and fixing in replacement of Hot press moulded Street light pole junction box size 255 x 355 x 122 mmout side dimension single hinged door fitted with one MCB 10 Amps and RYBN Connectors, 4 way complete all as directed Make: Hensel/Sintex/United/National
87Felling of tree exc. 30 cmofgirth including cutting of trunk, and branches and stacking of serviceable material and disposal of unserviceable material to a distance n exc. 50 m and clearing site
88Decarbonising/ cleaning of Existing LT panelcubical type of various size consists of bus bar and circuit chamber, metering chambers CTs and relays chambers, checking the bus bar joints, bus bar and circuit spouts, cleaning and applying Busbar Insulation Tape to the bus bars , checking the current transformer, applying Monoplast compound at the bus bar joints after tightening of joints ,replacednew suiable size of lugs /suitable copper control cableand reassembling , if any rusted sheet replaced with new sheet as per existing sizecomplete all as directed by Engineer-in-Charge.Note:- Cost of lubricant/ cleaning agents (CRC & rust remover) / hardware like springs/ bolts/ nuts/ washers,lugs/ suitable copper cables cost of labour, T&P required for replacement shall be etc. shall be deemed to be included in the rate quoted.
89Material and labour for painting to LT panel of any size by scrapping andremoving oil paint and applying 01 coats of synthetic enamel paint of approved colour by taking due coplete all as specified and directed by Engineer-in-charge .
90Material and labour for painting to 100-400 KVA transformer by scrapping andremoving oil paint and applying 01 coats of synthetic enamel paint of approved colour by taking due care for HT/LT side supply all as specified and directed by Engineer-in-charge .
91M & L for spreading crushed coarse stones aggregate upto 40mm grade suitable for substation yard complete all as specified and directed.
92Supplying and fixing 1100 volts grade heavy duty cable of 6 sqmm dia PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular complete all as directed. Make - Finolex /Havells/Polycab/Richa
93All as in Item No- 92 but for2 core 10 sqmm
94All as in Item No- 92 but for 2 core 16 sqmm
95Supply and fix3 phase LEDdigital Ammetersquare shape,Accuracy CL-0.5, with CT site selectable 1/5A, inbuilt selecteor switchsuitable for for panel including taking down Ammeter meter , all as specified and directed by Engineer-in-charge. Make -L&T/AE/C&S/Legrand
96Supply and fix3 phase LED digital Voltmeter for LT measurement square shape, Accuracy Type-0.5, inbuilt selecteor switchsuitable for for panel including taking down Volt meter , all as specified and directed by Engineer-in-charge.Make -L&T/AE/C&S/Legrand
97S & F LED indicating Lamps for R, Y, B phases complete including taking down ols U/S lamps all as specified and directed.Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor"s supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor"s firm name while carriying out any activities in defence area for better check of security purpose.Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)